At least 721 records · Page 40

Aerial Crosspolarized NQR-NMR: Buried Explosive Detection From a Safe Distance

Nuclear quadrupole resonance is a non-destructive detection and inspection technique with potential as a non-destructive test (NDT) tool. Establishment of the capability opens the door to its use in furthering the mission of the labs. There are many possible uses of the capability: explosive detection and stress/strain detection in epoxies are two of the more obvious and are the main results of this work. Enhancement of the signal-to-noise ratio (SNR) and improvements in the acquisition time of the experiment were key focuses of this work. These were achieved by combing special spin-lock pulse sequences with cross-polarization (CP) schemes to improve the signals with shorter acquisition times. A novel rotating magnetic field device was created to facilitate CP in the field. Implementation of these schemes provided a significant reduction in SNR/time.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Boron-10 Based Neutron Coincidence Counter for Safeguards

The shortage of 3He has triggered the search for effective alternative neutron detection technologies for national security applications, including international nuclear safeguards. Any alternative neutron detection technology must satisfy two basic criteria: it must meet a neutron detection efficiency requirement, and it must be insensitive to gamma-ray interference at a prescribed level while still meeting the neutron detection requirement. For nuclear safeguards, a system must perform measurements in the field with a prescribed precision in a specified time. This paper describes an effort to design, model and test an alternatives-based neutron coincidence counter for nuclear safeguards applications. The technology chosen for use in an alternatives-based uranium neutron coincidence collar was boron-lined proportional counters. Extensive modeling was performed of various system configurations and comparisons were made to measurements on a commercial prototype boron-10 based uranium neutron coincidence collar.

alternative neutron detectors↗

Observation of strongly forbidden solid effect dynamic nuclear polarization transitions via electron-electron double resonance detected NMR

We present electron paramagnetic resonance experiments for which solid effect dynamic nuclear polarization transitions were observed indirectly via polarization loss on the electron. This use of indirect observation allows characterization of the dynamic nuclear polarization (DNP) process close to the electron. Frequency profiles of the electron-detected solid effect obtained using trityl radical showed intense saturation of the electron at the usual solid effect condition, which involves a single electron and nucleus. However, higher order solid effect transitions involving two, three, or four nuclei were also observed with surprising intensity, although these transitions did not lead to bulk nuclear polarization—suggesting that higher order transitions are important primarily in the transfer of polarization to nuclei nearby the electron. Similar results were obtained for the SA-BDPA radical where strong electron-nuclear couplings produced splittings in the spectrum of the indirectly observed solid effect conditions. Observation of high order solid effect transitions supports recent studies of the solid effect, and suggests that a multi-spin solid effect mechanism may play a major role in polarization transfer via DNP.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Explosive Byproduct Gas Transport Through Sorptive Geomedia

Current underground nuclear explosion (UNE) detection strategies rely heavily on atmospheric noble gas sampling of radioxenon. However, discriminating nuclear weapons testing programs from civilian sources is difficult due to highly variable atmospheric radioxenon backgrounds and processes affecting subsurface transport of parent radionuclides. Here, we aim to study the transport of gases produced by subsurface explosions as novel stable signatures for underground nuclear explosion (UNE) monitoring. These gases may be produced in large quantities with distinct molecular ratios, which will be impacted by subsurface transport processes. To demonstrate how ratios of gases produced by explosions can change during transport in geomaterials, we conducted laboratory benchtop experiments on the transport of carbon dioxide (CO 2 ) and hydrogen (H 2 ) gases through variably saturated zeolitic tuff, which is abundant at the historic US testing site. We observed that zeolitic tuff sorbs substantial quantities of CO 2 while allowing H 2 to transport more freely, leading to changes in the molecular ratios of the two gases along the transport pathway. Gas uptake in the dry zeolitic tuff core was 72.3% for CO 2 , compared with 53.4% for xenon and 7.6% for H 2 . The presence of 20% water saturation disrupted the CO 2 sorption process, though to a lesser extent than observed for noble gases, with a 36.7% drop in xenon sorption compared with a 21.9% drop for CO 2 . These results represent the first observations of zeolite sorption altering explosive gas ratios during transport through geomedia relevant to nuclear proliferation monitoring.

54 ENVIRONMENTAL SCIENCES↗

Uncertainty quantification in application of the enrichment meter principle for nondestructive assay of special nuclear material

The various methods of nondestructive assay (NDA) of special nuclear material (SNM) have applications in nuclear nonproliferation, including detection and identification of illicit SNM at border crossings, and quantifying SNM at nuclear facilities for safeguards. No assay method is complete without “error bars,” which provide one way of expressing confidence in the assay result. Consequently, NDA specialists typically quantify total uncertainty in terms of “random” and “systematic” components, and then specify error bars for the total mass estimate in multiple items. Uncertainty quantification (UQ) for NDA has always been important, but it is recognized that greater rigor is needed and achievable using modern statistical methods. To this end, we describe the extent to which the guideline for expressing uncertainty in measurements (GUM) can be used for NDA. Also, we propose improvements over GUM for NDA by illustrating UQ challenges that it does not address, including calibration with errors in predictors, model error, and item-specific biases. A case study is presented using low-resolution NaI spectra and applying the enrichment meter principle to estimate the U-235 mass in an item. The case study illustrates how to update the current American Society for Testing and Materials guide for application of the enrichment meter principle using gamma spectra from a NaI detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

OR14-V-Uncertainty-PD2La Uncertainty Quantification for Nuclear Safeguards and Nondestructive Assay Final Report

The various methods of nondestructive assay (NDA) of special nuclear material (SNM) have applications in nuclear nonproliferation, including detection and identification of illicit SNM at border crossings and quantifying SNM at nuclear facilities for safeguards. No assay method is complete without “error bars,” which provide one way of expressing confidence in the assay result. Consequently, NDA specialists typically provide error bars and also partition total uncertainty into “random” and “systematic” components so that, for example, an error bar can be developed for the total mass estimate in multiple items. Uncertainty Quantification (UQ) for NDA has always been important, but it is recognized that greater rigor is needed and achievable using modern statistical methods.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Verifying Deep Reductions in the Nuclear Arsenals: Development and Demonstration of a Motion-detection Subsystem for a “Buddy Tag” Using Non-export Controlled Accelerometers

Future nuclear arms-control agreements may place numerical limits on items that are difficult to monitor with national technical means, even when complemented with onsite inspections. Such items could include small objects and mobile assets, such as non-deployed nuclear warheads and mobile missile launchers. Typically, this verification task can be addressed with unique identifiers, but standard tagging techniques may be unacceptable in this case due to host concerns about safety and intrusiveness. First proposed in the late 1980s and partially developed by Sandia National Laboratories in the early 1990s, the “Proximity Tag” or “Buddy Tag” concept seeks to overcome these concerns by separating the tag from the treaty accountable item itself. A buddy tag has two key elements: a tamper-indicating enclosure and a motion-detection system designed to detect illicit movements in a stand-down period. As part of this project, we have built a buddy-tag prototype for demonstration and evaluation purposes. This paper reviews the design choices and functionalities of the tag’s motion-detection subsystem.We pursue a modular approach for the tag’s hardware, built around an Arduino-class microcontroller and a non-export-controlled low-noise accelerometer, and use open-source algorithms for the motion-detection software. Finally, we discuss the results of an extensive experimental campaign involving both indoor and outdoor measurements assessing the performance of the tag under real-world environmental conditions.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

NGC 4314. I - Visible and short-wavelength infrared surface photometry of the nucleus and bar

BVI (TI CCD) and JHK (University of Texas IR Camera) surface photometry of NGC 4314, an SB (rs)ap anemic spiral with a nuclear ring containing recent star formation, is presented. The shortwave IR (SWIR) frames reveal a nuclear bar of length 2 arcsec at PA of 0 deg. The nuclear ring and associated dust were detected in all SWIR color indices. A nuclear spiral was detected in the visible and SWIR just exterior to the ring. Extremely low-amplitude spiral-shaped deficits were found in the stellar distribution in the SWIR in this same region. These are attributed to dust, since CO is detectable at or near these locations. Average minor-axis profiles show this galaxy to have a nuclear bulge obeying the de Vaucouleurs r exp 1/4 law for values in the range 2-7 arcsec. The extinction and scattering characteristics of dust near the sites of recent star formation in the nuclear ring are discussed.

Benedict, G. F.↗

Diamond as a solid state micro-fission chamber for thermal neutron detection at the VR-1 research reactor

Diamond exhibits a combination of properties which makes it attractive for neutron detection in hostile conditions. In the particular case of detection in a nuclear reactor, it is resilient to radiation, exhibits a natural low sensitivity to gamma rays, and its small size (as compared with that of gas ionisation chambers) enables fluency monitoring with a high position resolution. We report here on the use of synthetic CVD diamond as a solid state micro-fission chamber with U-235 converting material for in-core thermal neutron monitoring. Two types of thin diamond detectors were developed for this application. The first type of detector is fabricated using thin diamond membrane obtained by etching low-cost commercially available single crystal CVD intrinsic diamond, so called 'optical grade' material. Starting from a few hundred of micrometre thick samples, the sample is sliced with a laser and then plasma etched down to a few tenths of micrometre. Here we report the result obtained with a 17 μm thick device. The detection surface of this detector is equal to 1 mm{sup 2}. Detectors with surfaces up to 1 cm{sup 2} can be fabricated with this technique. The second type of detector is fabricated by growing successively two thin films of diamond, by the microwave enhanced chemical vapour deposition technique, on HPHT single crystal diamond. A first, a film of boron doped (p+) single crystal diamond, a few microns thick, is deposited. Then a second film of intrinsic diamond with a thickness of a few tens of microns is deposited. This results in a P doped, Intrinsic, Metal structure (PIM) structure in which the intrinsic volume id the active part of the detector. Here we report the results obtained with a 20 μm thick intrinsic whose detection surface is equal to 0.5 mm{sup 2}, with the possibility to enlarge the surface of the detector up to 1 cm{sup 2}. These two types of detector were tested at the VR-1 research reactor at the Czech Technical University in Prague. The Training Reactor VR-1 is a pool type (light water) reactor based on UO{sub 2} low enriched uranium. It has a nominal power of 1 kW, and can be operated for a short period up to 5 kW. The arrangement of the reactor pool reactor facilitates access to the core, setting and removal of various experimental samples and detectors, and safe and easy handling of fuel assemblies. The reactor is equipped with two horizontal channels (radial and tangential) and 10 vertical channels, of varying diameters, which can be loaded into various core positions, and one pneumatic transfer system. It is also equipped with several specifically designed educational instrumentation systems that can be used to supply complementary measurements and characterization around the reactor. The reactor is operated by the Department of Nuclear Reactors of the Faculty of Nuclear Sciences and Physical Engineering of the Czech Technical University in Prague. The two detectors were placed in-core through one of the vertical insertion channel. They were coupled to remote placed (5 m BNC cable) classical nuclear charge sensitive electronics. Detection properties of both sensors, including: pulse height spectra of U-235 fission fragments (response linearity with neutron flux, count rate, gamma background, were evaluated varying the power of the reactor from 0.005 W to 500 W. The evolution of the counting rate of the thinned optical grade detector as a function of counting rate of a gas ionization chamber used currently for reactor monitoring shows the very good linearity of the detector over the 5 decades. Similar results were obtained with the PIM detector. Additionally fast transient current signals of the detectors were recorded on a digital storage oscilloscope (DSO) using broad-band amplifier and with a simple bias-T, showing potential use of such sensors for neutron counting with no need of an amplification stage, since non-amplified signals from fission fragments exceeded 4 mV in amplitude. Therefore, one can think of simple neutron counting system by feeding diamond detectors signals directly to the low threshold discriminators. The results obtained on the VR1 will be described and discussed in detail in the paper and associated presentation. The results demonstrate that diamond micro-fission chambers can be used for in-core neutron monitoring, where robust, simple and compact devices are required.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Bio-Medical and Plant Biology Imaging Tools Derived from Nuclear Physics Detector Development

Basic nuclear physics research requires continuing advances in detector technology. Often, new detection technology can have applications outside basic nuclear physics research. For over 80 years various sciences have been using radioactive isotopes as tracers for increasing our understanding of biological processes in living systems. New nuclear physics detection technologies using scintillators and photo multipliers have been used to develop imaging tools for radioisotope detection and imaging in bio-medical and plant biology applications. Nuclear imaging techniques such as positron emission tomography (PET) and single photon emission computed tomography (SPECT) benefit greatly from advances in nuclear physics detector technology. Bio-medical research utilizing animals as in pre-clinical research and in clinical applications such as cancer detection and treatment have benefited much from nuclear physics detector advances. New imaging tools are being developed for plant biology research to enhance our understanding of metabolic processes necessary for efficient biofuel production in a changing environment and of best bioassays for environmental remediation. The Radiation Detector and Imaging Group at Thomas Jefferson National Accelerator Facility has been applying detector technology to these applications. The examples of detector systems for medical and plant biology applications as well as scientific motivations driving use of radioisotope tracers in these applications will be presented.

Weisenberger, Andrew↗

International Workshop on Best Practices in Material Hold-Up Monitoring

In the fall of 2006, the Oak Ridge National Laboratory (ORNL) hosted an INMM-sponsored International Workshop on Best Practices in Material Hold-Up Monitoring. This workshop represented the first time in over 20 years that the international community had gathered to discuss pertinent hold-up topics and needs. More than one hundred people attended the workshop. Their expertise in the field ranged from novice to expert, and they shared their experiences and expertise throughout the week of the workshop. Presenters discussed techniques that have been used worldwide to detect and characterize nuclear materials held up in processes and equipment and the policies used to report quantities detected. The primary goal of the workshop was to compile information on the best practices and lessons learned and to make this information available for sharing throughout the international community. This paper discusses the information that was produced from four separate working groups (each composed of workshop attendees). Each group was tasked to determine what it felt to be the best practices in the field today and what issues needed to be addressed to move the field forward in the 21st century.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Personnel Dose Assessment during Active Interrogation

A leading candidate in the detection of special nuclear material (SNM) is active interrogation (AI). Unlike passive interrogation, AI uses a source to enhance or create a detectable signal from SNM (usually fission), particularly in shielded scenarios or scenarios where the SNM has a low activity. The use of AI thus makes the detection of SNM easier or, in some scenarios, even enables previously impossible detection. During the development of AI sources, significant effort is put into determining the source strength required to detect SNM in specific scenarios. Usually during this process, but not always, an evaluation of personnel dose is also completed. In this instance personnel dose could involve any of the following: (1) personnel performing the AI; (2) unknown stowaways who are inside the object being interrogated; or (3) in clandestine interrogations, personnel who are known to be inside the object being interrogated but are unaware of the interrogation. In most instances, dose to anyone found smuggling SNM will be a secondary issue. However, for the organizations performing the AI, legal if not moral considerations should make dose to the personnel performing the AI, unknown stowaways, or innocent bystanders in clandestine interrogations a serious concern.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulation of Nuclear Resonance Fluorescence in Geant4

Abstract– Ongoing research at Pacific Northwest National Laboratory (PNNL) is assessing the utility of exploiting nuclear resonance fluorescence (NRF) to detect bulk samples of special nuclear materials, high explosives, and related illicit cargo constituents in a variety of cargo inspection scenarios. PNNL has developed a Monte Carlo radiation transport simulation capability for studying the NRF signal response in order to facilitate computational studies of these inspection scenarios. The simulation framework implements NRF as a new physics process, “G4NRF,” in the Geant4 modeling toolkit, and leverages the Evaluated Nuclear Structure Data File (ENSDF) database of nuclear level properties to determine isotope-specific parameters of the NRF response model in general cargo constituents. The G4NRF package has been benchmarked against bremsstrahlung photon-beam data collected at the University of California at Santa Barbara’s 5.3 MeV accelerator. A series of cargo-inspection scenario studies utilizing the NRF simulation package is currently in progress.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

PARSEC-SCALE RADIO EMISSION FROM THE LOW-LUMINOSITY ACTIVE GALACTIC NUCLEUS IN THE DWARF STARBURST GALAXY HENIZE 2-10

A candidate accreting massive black hole (BH) with M{sub BH} {approx} 10{sup 6} M{sub Sun} has recently been identified at the center of the dwarf starburst galaxy Henize 2-10 (He 2-10). This discovery offers the first possibility of studying a growing BH in a nearby galaxy resembling those in the earlier universe, and opens up a new class of host galaxies to search for the smallest supermassive BHs. Here we present very long baseline interferometry observations of He 2-10 taken with the Long Baseline Array (LBA) at 1.4 GHz with an angular resolution of {approx}0.''1 Multiplication-Sign 0.''03. A single compact radio source is detected at the precise location of the putative low-luminosity active galactic nucleus. The physical size of the nuclear radio emission is {approx}<3 pc Multiplication-Sign 1 pc, an order of magnitude smaller than previous constraints from the Very Large Array (VLA), and the brightness temperature of T{sub B} > 3 Multiplication-Sign 10{sup 5} K confirms a non-thermal origin. These LBA observations indicate that the nuclear radio emission originates from a single object, and exclude the possibility of multiple supernova remnants as the origin of the nuclear radio emission previously detected with the VLA at lower resolution. A weaker, more extended, off-nuclear source is also detected with the LBA and a comparison with multi-wavelength ancillary data indicate that, unlike the nuclear source, the off-nuclear source is co-spatial with a super star cluster, lacks a detectable X-ray point-source counterpart, and is almost certainly due to a supernova remnant in the host star cluster.

79 ASTRONOMY AND ASTROPHYSICS↗

Sequential Detection of Fission Processes for Harbor Defense

With the large increase in terrorist activities throughout the world, the timely and accurate detection of special nuclear material (SNM) has become an extremely high priority for many countries concerned with national security. The detection of radionuclide contraband based on their γ-ray emissions has been attacked vigorously with some interesting and feasible results; however, the fission process of SNM has not received as much attention due to its inherent complexity and required predictive nature. In this paper, on-line, sequential Bayesian detection and estimation (parameter) techniques to rapidly and reliably detect unknown fissioning sources with high statistical confidence are developed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron detection of the Triga Mark III reactor, using nuclear track methodology

Nuclear Track Methodology (NTM), based on the neutron-proton interaction is one often employed alternative for neutron detection. In this paper we apply NTM to determine the Triga Mark III reactor operating power and neutron flux. The facility nuclear core, loaded with 85 Highly Enriched Uranium as fuel with control rods in a demineralized water pool, provide a neutron flux around 2 × 10{sup 12} n cm{sup −2} s{sup −1}, at the irradiation channel TO-2. The neutron field is measured at this channel, using Landauer{sup ®} PADC as neutron detection material, covered by 3 mm Plexiglas{sup ®} as converter. After exposure, plastic detectors were chemically etched to make observable the formed latent tracks induced by proton recoils. The track density was determined by a custom made Digital Image Analysis System. The resulting average nuclear track density shows a direct proportionality response for reactor power in the range 0.1-7 kW. We indicate several advantages of the technique including the possibility to calibrate the neutron flux density measured at low reactor power.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Neutron Based Interrogation System For SNM In Cargo

A complete system has been simulated using experimentally obtained input parameters for the detection of special nuclear materials (SNM). A variation of the associated particle imaging (API) technique, referred to as reverse associated particle imaging detection (RAPID), has been developed in the context of detecting 5-kg spherical samples of U-235 in cargo. The RAPID technique allows for the interrogation of containers at neutron production rates between {approx}1x10{sup 8} neutrons/s and {approx}3x10{sup 8} neutrons/s. The merit of performance for the system is the time to detect the threat material with 95% probability of detection and 10{sup -4} false positive rate per interrogated voxel of cargo. Detection times of 5 minutes were found for a maximally loaded cargo container uniformly filled with iron and as low as 1 second in containers loaded to 1/4 of full capacity with either iron or wood. The worse case system performance, 30 minutes interrogation time, occurs for a maximally loaded container containing wood at 0.4 g/cm{sup 3}.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Insider Threat - Material Control and Accountability Mitigation

The technical objectives of nuclear safeguards are (1) the timely detection of diversion of significant quantities of nuclear material from peaceful uses to the manufacture of nuclear weapons or other nuclear explosive devices or for purposes unknown and (2) the deterrence of such diversion by the risk of early detection. The safeguards and security program must address both outsider threats and insider threats. Outsider threats are primarily addressed by the physical protection system. Insider threats can be any level of personnel at the site including passive or active insiders that could attempt protracted or abrupt diversion. This could occur by an individual acting alone or by collusion between an individual with material control and accountability (MC&A) responsibilities and another individual who has responsibility or control within both the physical protection and the MC&A systems. The insider threat is one that must be understood and incorporated into the safeguards posture. There have been more than 18 documented cases of theft or loss of plutonium or highly enriched uranium. The insider has access, authority, and knowledge, as well as a set of attributes, that make him/her difficult to detect. An integrated safeguards program is designed as a defense-in-depth system that seeks to prevent the unauthorized removal of nuclear material, to provide early detection of any unauthorized attempt to remove nuclear material, and to rapidly respond to any attempted removal of nuclear material. The program is also designed to support protection against sabotage, espionage, unauthorized access, compromise, and other hostile acts that may cause unacceptable adverse impacts on national security, program continuity, the health and safety of employees, the public, or the environment. Nuclear MC&A play an essential role in the capabilities of an integrated safeguards system to deter and detect theft or diversion of nuclear material. An integrated safeguards system with compensating mitigation can decrease the risk of an insider performing a malicious act without detection.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗