Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “module temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Higher Dimensionality in the Mg–Co–B System: Synthesis and Structure of Incommensurate Composite Mg 1+ε Co 4 B 4

Guided by high-temperature in situ X-ray diffraction, the discovery and synthesis of Mg 1+ε Co 4 B 4 (ε ≈ 0.272) using a MgH 2 hydride precursor is reported, along with a detailed crystal structure description and measurement of magnetic properties. The mismatch in lattice periodicities between Mg and Co–B substructures places Mg 1+ε Co 4 B 4 in the family of incommensurate composite crystals and prompted structural refinement in a (3 + 1)-dimensional model. The structure of Mg 1+ε Co 4 B 4 (P4 2 /ncm(00γ)s00s, a = 6.75847(7) Å, c = 3.94007(8) Å, q = (0, 0, 1.2721(3))) was refined from neutron powder diffraction and high-resolution powder X-ray diffraction data and confirmed by scanning transmission electron microscopy and electron diffraction. Mg 1+ε Co 4 B 4 is isostructural to Nd 1+ε Fe 4 B 4 and several related ternary borides with 0.07 ≤ ε ≤ 0.17, with Mg occupying the rare-earth site. Satellite reflections in the electron diffraction patterns hinted at positional modulation of the transition metal–boron substructure by Mg atoms, but this could not be refined from the neutron or X-ray diffraction data. Low-temperature magnetic measurements show no indications of long-range magnetic ordering or superconductivity down to 5 K. DFT calculations confirmed the absence of a magnetically ordered ground state and the stability of a 5:4 supercell (ε = 0.25) relative to the fully commensurate structure. Neutron diffraction and synthesis from elemental Mg demonstrated that Mg 1+ε Co 4 B 4 is not a hydrogen-stabilized phase. Mg 1+ε Co 4 B 4 represents the second compound reported in the Mg–Co–B system and the first superspace symmetry model of a Nd 1+ε Fe 4 B 4 -type incommensurate composite compound refined from powder diffraction data.

chemical structure↗

Weather Systems Connecting Modes of Climate Variability to Regional Hydroclimate Extremes

Abstract Weather system clustering provides a high‐level summary of regional meteorological conditions. Most quantitative clustering schemes focus on precipitation alone, which does not sufficiently describe the meteorological conditions driving hydroclimate variability. This study presents the Weather Anomaly Clustering (WAC‐hydro), which extends the existing capability of predicting weather systems to predicting hydroclimate variability. Focusing on both precipitation and temperature predictions, WAC‐hydro identifies 12 clusters of daily weather anomaly modes in the US Pacific Northwest Puget Sound region during 1981–2020. The influence of El Niño‐Southern Oscillation and Madden‐Julian Oscillation on regional precipitation can be well approximated by their modulation on the weather clusters. Within each weather cluster, local factors such as topography only play a secondary role in the hydrologic variability. The weather clusters highlight two types of flood‐inducing regional weather conditions, one causing floods by inducing positive precipitation anomalies and the other causing floods through combined precipitation and temperature‐induced rain‐on‐snow effect.

54 ENVIRONMENTAL SCIENCES↗

Demonstrating non-isothermal vacuum membrane air dehumidification for efficient next-generation air conditioning

Vacuum membrane air dehumidification has gained significant interest in recent years as a highly efficient means of air dehumidification. Prior theoretical modeling work by the authors introduced the Active Membrane Energy Exchanger (AMX) concept, which combines active heat exchange and vacuum membrane dehumidification into one non-isothermal system, and found that it could outperform other air conditioning technologies under many conditions. However, no experimental literature exists on combining active heat exchangers and vacuum membrane dehumidification. Here, the goal of the present study is to evaluate the dehumidification (mass transfer) performance of the AMX concept relative to isothermal membrane dehumidification through three main methodologies: (1) membrane material-level characterization, (2) experimental prototype development and testing, and (3) computational fluid dynamics (CFD) simulations. The dense membranes used in this work showed up to a 40% increase in water vapor permeance at cooler temperatures, and the prototype system showed up to a 6% increase in humidity removal when the air was simultaneously cooled. Furthermore, the membrane module-integrated heat exchange tubes provided additional mixing and turbulence, leading to a 4–8% increase in humidity removal. The upper limit coefficient of performance was equal to approximately 2.2, necessitating advanced system designs to improve efficiency. This study is the first to highlight that combining the cooling and vacuum dehumidification processes can improve dehumidification performance.

30 DIRECT ENERGY CONVERSION↗

Reversible multicolor chromism in layered formamidinium metal halide perovskites

Abstract Metal halide perovskites feature crystalline-like electronic band structures and liquid-like physical properties. The crystal–liquid duality enables optoelectronic devices with unprecedented performance and a unique opportunity to chemically manipulate the structure with low energy input. In this work, we leverage the low formation energy of metal halide perovskites to demonstrate multicolor reversible chromism. We synthesized layered Ruddlesden-Popper FA n+1 Pb n X 3n+1 (FA = formamidinium, X = I, Br; n = number of layers = 1, 2, 3 … ∞) and reversibly tune the dimensionality ( n ) by modulating the strength and number of H-bonds in the system. H-bonding was controlled by exposure to solvent vapor (solvatochromism) or temperature change (thermochromism), which shuttles FAX salt pairs between the FA n+1 Pb n X 3n+1 domains and adjacent FAX “reservoir” domains. Unlike traditional chromic materials that only offer a single-color transition, FA n+1 Pb n X 3n+1 films reversibly switch between multiple colors including yellow, orange, red, brown, and white/colorless. Each colored phase exhibits distinct optoelectronic properties characteristic of 2D superlattice materials with tunable quantum well thickness.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Heterotrophic respiration by soil microbes in a changing climate

Soil microbes strongly influence the soil organic carbon (SOC) pool, which globally stores ~2,000 PgC. Specifically, the balance between microbial heterotrophic respiration (R H ), which degrades SOC, and plant–microbe interactions that stabilize SOC determines whether terrestrial ecosystems are a net source or sink of CO 2 to the atmosphere. Here, in this Review, we evaluate how climate change alters these competing processes. R H is approximately half of total soil respiration, at ~50 PgC yr −1 , with 70% occurring in topsoils. Warming accelerates microbial metabolism, with a 10 °C temperature increase estimated to raise R H by ~50%, an effect that is particularly strong in Arctic soils. Warming also reduces soil moisture, further modulating R H , which responds nonlinearly to soil moisture, being limited by saturation and desiccation and meeting a maximum at intermediate levels. Consequently, R H is highly sensitive to future precipitation changes and drought. However, soil management strategies could enhance SOC stocks and persistence under climate change. Bacterial and fungal inoculants can promote SOC production and stabilization, while deep-rooting plants increase SOC inputs to deeper layers that experience lower R H . Agricultural practices and biochar amendments can also enhance SOC and reduce R H . Expanding field trials across regions, climates and soil types would improve empirical understanding of these responses and support better representation of R H in predictive models, enabling more accurate assessments of climate impacts on SOC storage.

Jansson, Janet K. [Pacific Northwest National Labo↗

System-on-chip approach microwave imaging reflectometer on DIII-D tokamak

System-on-chip millimeter wave integrated circuit technology is used on the two-dimensional millimeter-wave imaging reflectometer (MIR) upgrade for density fluctuation imaging on the DIII-D tokamak fusion plasma. Customized CMOS chips have been successfully developed for the transmitter module and receiver module array, covering the 55–75 GHz working band. The transmitter module has the capability of simultaneously launching eight tunable probe frequencies (>0 dBm output power each). The receiver enclosure contains 12 receiver modules in two vertical lines. The quasi-optical local oscillator coupling of previous MIR systems has been replaced with an internal active frequency multiplier chain for improved local oscillator power delivery and flexible installation in a narrow space together with improved shielding against electromagnetic interference. The 55–75 GHz low noise amplifier, used between the receiver antenna and the first-stage mixer, significantly improves module sensitivity and suppresses electronics noise. The receiver module has a 20 dB gain improvement compared with the mini-lens approach and better than –75 dBm sensitivity, and its electronics noise temperature has been reduced from 55 000 K down to 11 200 K. Further, the V-band MIR system is developed for co-located multi-field investigation of MHD-scale fluctuations in the pedestal region with W-band electron cyclotron emission imaging on DIII-D tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Discretized hexagonal boron nitride quantum emitters and their chemical interconversion

Quantum emitters in two-dimensional hexagonal boron nitride (hBN) are of significant interest because of their unique photophysical properties, such as single-photon emission at room temperature, and promising applications in quantum computing and communications. The photoemission from hBN defects covers a wide range of emission energies but identifying and modulating the properties of specific emitters remain challenging due to uncontrolled formation of hBN defects. In this study, more than 2000 spectra are collected consisting of single, isolated zero-phonon lines (ZPLs) between 1.59 and 2.25 eV from diverse sample types. Most of ZPLs are organized into seven discretized emission energies. All emitters exhibit a range of lifetimes from 1 to 6 ns, and phonon sidebands offset by the dominant lattice phonon in hBN near 1370 cm -1 . Two chemical processing schemes are developed based on water and boric acid etching that generate or preferentially interconvert specific emitters, respectively. The identification and chemical interconversion of these discretized emitters should significantly advance the understanding of solid-state chemistry and photophysics of hBN quantum emission.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Heavy Rainfall Mechanism Revealed by a Terrain-Resolving 4DVar Data Assimilation System—A Case Study

In this study, a newly developed terrain-resolving four-dimensional variational (4DVar)-based data assimilation system, Immersed Boundary Method_Variational Doppler Radar Analysis System (IBM_VDRAS), is applied to investigate the mechanisms leading to a heavy precipitation event that occurred in Taiwan during the Southwesterly Monsoon Experiment (SoWMEX) conducted in 2008. The multivariate analyses using IBM_VDRAS and surface observations reveal that the warm and moist southwesterly flow from the ocean decelerates after making landfall, forming a surface convergence zone along the coast, which is further strengthened during the passage of a prefrontal rainband. The flow ascends as it advances inland until reaching the mountains, producing persistent precipitation and the enhancement of evaporative cooling as well as a widespread high pressure zone. A very shallow (<0.4 km) layer of offshore flow can be identified over the southwestern plain, which helps to generate a quasi-stationary convergence zone near the coast. Furthermore, sensitivity studies are carried out to quantify the relative importance of the contributions made by topographic blockage, evaporative cooling, and their nonlinear interaction, to the evolution of this type of convective system. The influence of the topography is identified as the dominant factor in modulating the flow structure of the rainfall system. However, it is the nonlinear interaction between terrain and evaporation that determines the distribution of the temperature and pressure fields.

54 ENVIRONMENTAL SCIENCES↗

Upgrading Biogas through in situ Conversion of Carbon Dioxide to Biomethane in Anaerobic Digesters

Organic waste streams generated by wastewater treatment plants, agricultural operations, and food processing industries represent an important yet underutilized opportunity for renewable energy production in the United States. Through anaerobic digestion, these waste streams can produce biogas, a mixture primarily composed of methane (CH4) and carbon dioxide (CO2), that can be upgraded to pipeline-quality natural gas. However, most existing upgrading technologies remove CO2 from biogas rather than utilizing it, leaving a significant portion of the potential energy unused. This project investigates a novel biological upgrading approach that converts CO2 into additional CH4 by supplying hydrogen (H2) to specialized microorganisms capable of performing hydrogenotrophic methanation. The main challenges associated with biological biogas upgrading are related to hydrogen supply, gas-liquid mass transfer, and process stability. First, due to the high cost of hydrogen gas, it is preferable that H2 be produced on-site using renewable energy sources such as wind or solar power. Second, hydrogen has low solubility in liquids, which limits its availability to microorganisms and requires strategies to improve gas dissolution and transfer within the reactor. Third, process inhibition may occur as a result of increased pH caused by CO2 consumption or elevated H2 partial pressure, both of which can negatively affect methanogenic activity. Although research in these areas has advanced during the course of this project, these challenges have not yet been fully resolved. To date, the biological systems that have achieved the highest methane concentrations are typically ex-situ reactors, where operational conditions can be more easily controlled. For this reason, the findings of the present project remain highly relevant. The project goal was to develop an innovative system that can accomplish biogas upgrading via biological conversion of CO2 to CH4, in a novel hybrid approach that combines the advantages of both in-situ and ex-situ systems. The proposed system employs a three-phase upflow anaerobic bioreactor with H2 delivery through a gas-permeable membrane, enabling efficient hydrogen transfer and microbial conversion. Under optimized operating conditions, the system achieved 99% H2 consumption and 90% CO2 conversion. A subsequent gas cleaning stage was implemented to further improve gas quality and meet target purity standards. The upgraded gas composition reached 97.7% CH4, 2.2% CO2, and 0.97% O2, while H2S concentrations remained below detection limits. In addition, a flue gas-driven inorganic thermoelectric generator (TEG) system was designed and experimentally validated as a potential source of electricity for H2 production. The system consisted of six TEG modules connected in series and achieved an open-circuit voltage of 4.5 V and a maximum power output of 224 mW at a temperature difference of approximately 53.5 °C, demonstrating effective conversion of waste heat into electrical power under simulated flue gas conditions. Finally, a comprehensive techno-economic analysis was completed to evaluate the capital and operating costs associated with the proposed system. The results provide important insights to guide future scale-up, optimization, and potential deployment of integrated biological biogas upgrading technologies.

09 BIOMASS FUELS↗

Fast response High Altitude Laser Optical Sensor (HALOS) for atmospheric water and temperature measurements

Advanced instrumentation and sensing methods are the key factor in the determination of many climate science research problems. In this Phase I STTR a laser-based diagnostic system for atmospheric temperature and water concentrations measurements was developed, this system, HALOS – High Altitude Laser Optical Sensor, employs a mid-infrared (MIR) quantum cascade laser (QCL) of the distributed feedback variety (DFB) powered by a 100 kHz rep rate ramp modulated current profile which enables spectral profiling. Measurements made during Phase I showed that HALOS can surpass the available hygrometers refresh rates while offering superior accuracy (<4%) from the low Frost Point (Tfrost) of -110°C to dew points (Tdew) at 35°C while being able to encompass sub ppm concentration at altitude and supersaturated conditions at ground level. Readings from HALOS include temperature sensitivity on the order of 0.2°C and absolute humidity sensitivity (AH) on the order of 0.010 μmol/m 3 (0.18 mg/m 3 ) at a data output rate exceeding 1 kHz. HALOS can be easily integrable in existing Department of Energy (DOE) or National Oceanic and Atmospheric Administration (NOAA) conventional or remote operated aircraft having either a fixed or rotary wing.

54 ENVIRONMENTAL SCIENCES↗

Experimental Investigation on Cooling performance of A Thermoelectric Freezer

Thermoelectric heat pumps (TEHPs) have found widespread use in the electronics cooling industry and portable refrigerators. However, there has been a lack of extensive research on the application of TEHPs in low-temperature refrigeration settings. To address this gap, various configurations of TEHPs were fabricated to assess their suitability for freezer applications. Key parameters such as cooling capacity and system performance of the TEHPs were crucial in evaluating these configurations. Three configurations, each with different numbers of cooling units and fan arrangements, were tested using a 300-liter freezer prototype under typical room conditions (21°C). A cooling unit is comprised of two-stage thermoelectric modules, an aluminum plate fin heat exchanger sink with fans positioned either on top or directing airflow through the center, and a cooling block with circulating icy water for heat dissipation. Across all configurations, the minimum temperature inside the freezer cabinet reached -16.0°C. The cooling capacity peaked at 74.7 W, with the thermoelectric coefficient of performance (COP) reaching a maximum of 0.45. System COP ranged from 0.23 to 0.28. Minimum TE power consumption was recorded at 138.8 W, with TE system power consumption at 174.4 W, indicating feasibility for practical residential freezer applications. This investigation lays the foundation for integrating TE freezers with ice thermal storage systems.

Hu, Yifeng↗

Advances in Carbon Electrode Integration for Stable and Efficient Perovskite Solar Cells and Modules

Carbon-electrode-based perovskite solar cells (C-PSCs) have emerged as a cost-effective and scalable alternative to noble-metal-based PSCs, addressing critical challenges related to device stability, fabrication complexity, and commercialization potential. This review explores the recent progress in C-PSC development, focusing on the benefits of carbon electrodes (CEs), including their hydrophobicity, chemical inertness to halide corrosion, and compatibility with low-temperature cost-effective solution-based deposition methods. Despite relatively lower power conversion efficiencies (PCEs) than their metal (e.g., Au/Ag) counterparts, recent advances in carbon paste formulation, interfacial contact engineering, and work function modification have elevated C-PSC efficiencies above 22%. This review further examines strategies to enhance electrode conductivity, interfacial properties, and charge selectivity to further increase C-PSC performance. Progress in carbon-electrode-based perovskite solar modules (C-PSMs), particularly within mesoporous and planar architectures, is also analyzed, revealing significant developments in active area scaling and long-term stability. Notably, the limited research in inverted (PIN) C-PSCs is also highlighted as a compelling opportunity for innovation, given the architecture's inherent advantages in flexibility, tandem integration, and low-temperature processing. Collectively, these insights affirm the potential of C-PSCs and C-PSMs to deliver affordable, stable, and high-performance photovoltaics suitable for scalable deployment.

Carbon Electrodes↗

Analyzing Mechanical integrity of Microwave resonant Cavity flowmeter

The microwave resonant cavity flow sensor has been proposed to address the difficulties of measuring high-temperature molten salt flow in reactor vessels. The flow sensor consists of a metallic cylindrical cavity coupled to a microwave waveguide. The cylindrical cavity has one of the flat surfaces thin enough to undergo microscopic deflection due to dynamic pressure of the exerted by the flowing fluid. Deflection of the membrane causes a shift in the microwave resonant frequency. Fluid velocity can be estimated from the calibration curve. The objective of this report is to investigate mechanical integrity of the flowmeter’s membrane. The membrane is a thin stainless-steel circular plate with a clamped edge, subjected to uniform load. By calculating the stress on the plate due to deflection and, comparing the stress to the material ultimate tensile strength and yield strength, it can be estimated if the plate will fail. If the maximum stress is greater than the yield strength, the plate will undergo plastic deformation, and the sensor will be disabled. A stress greater than the ultimate tensile strength will cause the plate to fracture. The stress on the plate was calculated with an analytic closed form solution model, and with COMSOL Structural Mechanics Module which does not involve any approximations. Stresses in both the analytic model and COMSOL numerical model were calculated for stainless steel 316 thin circular plates under room temperature conditions, where the fluid is water. The diameter of the circular plate is approximately one inch, and thickness is 10mil. Fluid flow velocity is in the range from 0.5m/s to 1m/s. The results from the two models are similar. Both the analytic model and COMSOL model showed that maximum stresses on the plate, which are at the radial boundary of the plate, are three orders of magnitude smaller than the yield strength and ultimate tensile strength. This indicates that the sensor is at a low risk of mechanical failure.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Exploring the Atmospheric Dynamics of the Extreme Ultrahot Jupiter KELT-9b Using TESS Photometry

We carry out a phase-curve analysis of the KELT-9 system using photometric observations from NASA’s Transiting Exoplanet Survey Satellite (TESS). The measured secondary eclipse depth and peak-to-peak atmospheric brightness modulation are 650{sub −15}{sup +14} and 566 ± 16 ppm, respectively. The planet’s brightness variation reaches maximum 31 ± 5 minutes before the midpoint of the secondary eclipse, indicating a 5.°2 ± 0.°9 eastward shift in the dayside hot spot from the substellar point. We also detect stellar pulsations on KELT-9 with a period of 7.58695 ± 0.00091 hr. The dayside emission of KELT-9b in the TESS bandpass is consistent with a blackbody brightness temperature of 4600 ± 100 K. The corresponding nightside brightness temperature is 3040 ± 100 K, comparable to the dayside temperatures of the hottest known exoplanets. In addition, we detect a significant phase-curve signal at the first harmonic of the orbital frequency and a marginal signal at the second harmonic. While the amplitude of the first harmonic component is consistent with the predicted ellipsoidal distortion modulation assuming equilibrium tides, the phase of this photometric variation is shifted relative to the expectation. Placing KELT-9b in the context of other exoplanets with phase-curve observations, we find that the elevated nightside temperature and relatively low day–night temperature contrast agree with the predictions of atmospheric models that include H{sub 2} dissociation and recombination. The nightside temperature of KELT-9b implies an atmospheric composition containing about 50% molecular and 50% atomic hydrogen at 0.1 bar, a nightside emission spectrum that deviates significantly from a blackbody, and a 0.5–2.0 μm transmission spectrum that is featureless at low resolution.

79 ASTRONOMY AND ASTROPHYSICS↗

Design of microwave broadband CMOS transmitter and receiver circuits for MIR and ECEI plasma diagnostics

To efficiently determine the plasma electron density fluctuations using the MIR diagnostic technique, a 55–75 GHz 65 nm-CMOS transmitter has been developed where four separate intermediate frequency (IF) signals are up-converted, amplified, and then combined to generate an 8-tone RF output; a broadband 90 nm-CMOS receiver has also been constructed, which consists of an RF-low noise amplifier (LNA), mixer, and IF amplifier. The circuits and their corresponding modules will soon be deployed on the DIII-D and NSTX-U fusion devices. A 110–140 GHz 65 nm-CMOS receiver has also been designed, which is suitable for measuring the deep-core temperature fluctuations in the DIII-D tokamak using the electron cyclotron emission imaging diagnostic system. In addition to the RF-LNA/balun, mixer, and IF amplifier, an LO balun/tripler and driving amplifier are now included in this highly integrated circuit chip. By adopting the microwave and millimeterwave system-on-chip concept in the front-end system design, this paper demonstrates that compact transmitter and receiver modules can be easily built, which, in turn, facilitates array implementation and maintenance.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-Temperature Gas-Cooled Reactors Multiphysics Simulation Demonstration and Code Validation

This study presents a comprehensive benchmarking and verification effort of several thermal-hydraulic and multiphysics capabilities for high-temperature gas-cooled reactor applications. The first part of this effort focuses on the running-in verification of Griffin’s multiphysics capabilities, specifically for simulating the evolution of pebble-bed reactor cores from startup to equilibrium. Since Fiscal Year 2024, improvements and enhancements have been implemented in Griffin, including simplifying the process to specify streamlines and developing the online cross-section generation capability. In the absence of validation data, code-to-code comparisons are conducted with kugelpy, showing good agreement for integral quantities like k-eff predictions and predictions for maximum power density. However, accuracy issues are noted for more detailed quantities like the spatial distribution of fission rate densities which will require further work to address. The second part of this report presents an improved System Analysis Module (SAM) core channel model where the effects of cross flow are considered during the pressurized loss of forced cooling transient, resulting in an improved agreement of the predicted pebble temperature with respect to the predictions from the SAM 2D porous media model. Additionally, the wall channeling effect due to variable porosity at the near wall region of the core is also investigated. Furthermore, to demonstrate Griffin’s online cross-section generation capability, a Multiphysics simulation is performed by coupling Griffin to the SAM core channel model. In the third part of the report, as a part of the Organisation for Economic Co-operation and Development/Nuclear Energy Agency (OECD/NEA) thermal-hydraulic code validation benchmark activity for a high-temperature gas-cooled reactor, the High Temperature Test Facility (HTTF) is investigated first using the NekRS computational fluid dynamics (CFD) code to study the flow mixing phenomenon in the lower plenum of the facility. Then, code-to-code and code-to-data comparisons are performed for Test PG27, which is a pressurized conduction cooldown (PCC) test, using five different codes by six organizations from five countries. The different simulations show good agreements in terms of the general trend but there are differences in some results such as the peak temperatures of different regions and heat removal rate.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Unique safety features and licensing requirements of the NuScale small modular reactor

Small modular reactors (SMR) offer a novel approach to the construction and operation of nuclear power plants. The NuScale VOYGR™ plant uses a simplified SMR design that is based on proven light-water reactor technology with substantial improvements in nuclear safety. It consists of a 250 MWt reactor core housed with other primary system components in an integral reactor pressure vessel surrounded by a steel containment vessel, all of which is immersed in a large pool of water that also serves as the ultimate heat sink. At the core of the NuScale safety case are three primary safety systems: the decay heat removal system, the emergency core cooling system, and the containment. The ability of the NuScale Power Module (NPM) passive safety systems to remove core decay heat for an unlimited duration is demonstrated through analysis of a beyond-design-basis extended loss of AC power with no replenishment of water to the ultimate heat sink or operator actions. The NuScale methodology to evaluate an indefinite loss of AC power uses the proprietary NRELAP5 systems analysis computer code. Analysis results show that the reactor coolant system liquid level above the core is maintained and that containment pressure remains below the vessel design pressure. Once full passive air cooling is established, containment pressure and temperature will decrease over time with decreasing core decay heat. NuScale received standard design approval in September 2020 and design certification in January 2023 for its 50 MWe NPM configured as a 12 module plant. NuScale is currently seeking standard design approval to increase its core power to 250 MWt, nominally 77 MWe per module, in a 6-module plant (VOYGR™-6) configuration. The high-level safety of NuScale’s SMR technology is foundational to a new standard of nuclear power plant resilience.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗