Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “mathematical techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Basic research planning in mathematical pattern recognition and image analysis

Fundamental problems encountered while attempting to develop automated techniques for applications of remote sensing are discussed under the following categories: (1) geometric and radiometric preprocessing; (2) spatial, spectral, temporal, syntactic, and ancillary digital image representation; (3) image partitioning, proportion estimation, and error models in object scene interference; (4) parallel processing and image data structures; and (5) continuing studies in polarization; computer architectures and parallel processing; and the applicability of "expert systems" to interactive analysis.

Bryant, J.↗

A new mathematical approach to finding global solutions of the magnetic structure determination problem

Abstract Determination of magnetic structure is an important analytical procedure utilized in various fields ranging from fundamental condensed-matter physics and chemistry to advanced manufacturing. It is typically performed using a neutron diffraction technique; however, finding global solutions of the magnetic structure optimization problem represents a significant challenge. Generally, it is not possible to mathematically prove that the obtained magnetic structure is a truly global solution and that no solution exists when no acceptable structure is found. In this study, the global optimization technique called semidefinite relaxation of quadratic optimization, which has attracted much interest in the field of applied mathematics, is proposed to use as a new analytical method for the determination of magnetic structure, followed by the application of polarized neutron diffraction data. This mathematical approach allows avoiding spurious local solutions, decreasing the amount of time required to find a tentative solution and finding multiple solutions when they exist.

97 MATHEMATICS AND COMPUTING↗

A Survey of Techniques for Modeling and Improving Reliability of Computing Systems

Recent trends of aggressive technology scaling have greatly exacerbated the occurrences and impact of faults in computing systems. This has made `reliability' a first-order design constraint. To address the challenges of reliability, several techniques have been proposed. In this study, we provide a survey of architectural techniques for improving resilience of computing systems. We especially focus on techniques proposed for microarchitectural components, such as processor registers, functional units, cache and main memory etc. In addition, we discuss techniques proposed for non-volatile memory, GPUs and 3D-stacked processors. To underscore the similarities and differences of the techniques, we classify them based on their key characteristics. We also review the metrics proposed to quantify vulnerability of processor structures. Finally, we believe that this survey will help researchers, system-architects and processor designers in gaining insights into the techniques for improving reliability of computing systems.

3D-stacked processors↗

Validation of a Custom-made Software for DQE Assessment in Mammography Digital Detectors

This works presents the validation of a custom-made software, designed and developed in Matlab, intended for routine evaluation of detective quantum efficiency DQE, according to algorithms described in the IEC 62220-1-2 standard. DQE, normalized noise power spectrum NNPS and pre-sampling modulation transfer function MTF were calculated from RAW images from a GE Senographe DS (FineView disabled) and a Siemens Novation system. Calculated MTF is in close agreement with results obtained with alternative codes: MTF lowbar tool (Maidment), ImageJ plug-in (Perez-Ponce) and MIQuaELa (Ayala). Overall agreement better than {approx_equal}90% was found in MTF; the largest differences were observed at frequencies close to the Nyquist limit. For the measurement of NNPS and DQE, agreement is similar to that obtained in the MTF. These results suggest that the developed software can be used with confidence for image quality assessment.

97 MATHEMATICS AND COMPUTING↗

Bleeding Scrotal Vascular Lesions: Interventional Management with Transcatheter Embolization

Vascular lesions of the scrotum are uncommon; the most common among them are varicocele lesions. The other vascular lesions that may involve the scrotum are hemangioma, lymphangioma, and arteriovenous malformations, which are exceedingly rare. The imaging modalities useful in the diagnosis and management of scrotal vascular lesions are grayscale sonography, color Doppler sonography, magnetic resonance imaging, magnetic resonance angiography, and digital subtraction angiography. We present two cases of scrotal vascular lesions involving the extratesticular scrotal soft tissues. Patients presented with bleeding and were treated by radiological interventional technique. We emphasize the importance of superselective catheterization and distal embolization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Burden of Hard Atherosclerotic Plaques Does Not Promote Endoleak Development After Endovascular Aortic Aneurysm Repair: A Risk Stratification

Purpose: To objectify the influence of the atherosclerotic burden in the proximal landing zone on the development of endoleaks after endovascular abdominal aortic aneurysm repair (EVAR) or thoracic endovascular aneurysm repair (TEVAR) using objective aortic calcium scoring (ACS). Materials and Methods: This retrospective observation study included 267 patients who received an aortic endograft between 1997 and 2010 and for whom preoperative computed tomography (CT) was available to perform ACS using the CT-based V600 method. The mean follow-up period was 2 {+-} 2.3 years. Results: Type I endoleaks persisted in 45 patients (16.9%), type II in 34 (12.7%), type III in 8 (3%), and type IV or V in 3 patients, respectively (1.1% each). ACS in patients with type I endoleaks was not increased: 0.029 {+-} 0.061 ml compared with 0.075 {+-} 0.1349 ml in the rest of the patients, (p > 0.05; Whitney-Mann U-Test). There were significantly better results for the indication 'traumatic aortic rupture' than for the other indications (p < 0.05). In multivariate logistic regression analyses, age was an independent risk factor for the development of type I endoleaks in the thoracic aorta (Wald 9.5; p = 0.002), whereas ACS score was an independent protective factor (Wald 6.9; p = 0.009). In the abdominal aorta, neither age nor ACS influenced the development of endoleaks. Conclusion: Contrary to previous assumptions, TEVAR and EVAR can be carried out without increasing the risk of an endoleak of any type, even if there is a high atherosclerotic 'hard-plaque' burden of the aorta. The results are significantly better for traumatic aortic.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dynamic Contrast-Enhanced MRI Kinetics of Invasive Breast Cancer: A Potential Prognostic Marker for Radiation Therapy

Purpose: Our goal was to determine the correlations between dynamic contrast-enhanced MRI (DCE-MRI) kinetics of breast cancers and axillary nodal status (ANS) which may have prognostic value in designing radiation therapy recommendations. Methods and Materials: A retrospective review identified 167 consecutive patients treated with external beam radiotherapy for invasive breast cancer from Jan 1, 2006 to Nov 1, 2007. Patients with DCE-MRI kinetic data from our institution who underwent axillary surgical staging prior to chemotherapy were included. ANS was assessed as positive or negative by pathology record review. For each primary cancer, maximum tumor diameter and kinetic values for initial peak enhancement (PE), percent initial rapid enhancement (RE), and percent delayed washout enhancement (WE) were measured with a computer-aided evaluation program. Univariate, multivariate, and receiver operating characteristic curve analyses were performed according to the ANS. Results: Forty-six patients met study criteria, with 32 (70%) node-negative and 14 (30%) node-positive patients. Median PE was significantly greater in node-positive patients (209%) than in node-negative patients (138%, p = 0.0027). Similarly, median RE was significantly greater in node-positive patients (57%) than in node-negative patients (27%, p = 0.0436). WE was not different between groups (p = 0.9524). Median maximum tumor diameter was greater in node-positive patients (26 mm) than in node-negative patients (15 mm, p = 0.015). Multivariate analysis showed that only PE trended toward significance (p = 0.18). Conclusions: DCE-MRI kinetics of primary breast cancers correlate with ANS. Multivariate analysis demonstrates the correlation is not due simply to underlying lesion size. If validated prospectively, DCE-MRI kinetics may aid as a tool in selecting patients or designing fields for radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Factors Associated With Seroma Volume Reduction in Breast-Conserving Therapy for Early-Stage Breast Cancer: A Multi-Institutional Analysis

Purpose: To correlate clinical factors with seroma volume and reduction; and to determine whether cone-beam CT (CBCT) could be used clinically to monitor seroma reduction. Patients and Methods: This investigation included 102 women from five institutions with stage T1-2 breast cancer treated with breast-conserving therapy. Two CT scans were acquired: the planning CT (CT1) and a second CT (CT2) during radiotherapy (RT). Seroma was contoured on all scans, and correlations between seroma characteristics and clinical factors were investigated by univariate and multivariate analyses. In a substudy, 10 of the 102 patients received multiple CBCT scans during RT. Seroma were contoured by two observers in the substudy. Fifteen time points at which CT and CBCT were performed within 2 days were identified. The levels of correlation in seroma contours between CBCT and CT and between the two observers were examined. Results: The mean relative seroma reduction from CT1 to CT2 was 54% (p < 0.001). A significant inverse relationship was found between relative seroma reduction per week and number of RT fractions given by univariate and multivariate analyses (p = 0.01, 0.03). The mean difference in contoured seroma volumes between CT and CBCT was 12% (3.3 cm{sup 3}). When assessing the relative difference in seroma contours between Observer 1 and Observer 2, an interobserver difference of 12% was demonstrated. Neither discrepancy was clinically significant. Conclusions: Radiotherapy seems to hinder seroma reduction. Volume discrepancies between CBCT and CT were minor, with low interobserver variation, indicating that CBCT might be useful in monitoring seroma reduction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Accurate Automatic Delineation of Heterogeneous Functional Volumes in Positron Emission Tomography for Oncology Applications

Purpose: Accurate contouring of positron emission tomography (PET) functional volumes is now considered crucial in image-guided radiotherapy and other oncology applications because the use of functional imaging allows for biological target definition. In addition, the definition of variable uptake regions within the tumor itself may facilitate dose painting for dosimetry optimization. Methods and Materials: Current state-of-the-art algorithms for functional volume segmentation use adaptive thresholding. We developed an approach called fuzzy locally adaptive Bayesian (FLAB), validated on homogeneous objects, and then improved it by allowing the use of up to three tumor classes for the delineation of inhomogeneous tumors (3-FLAB). Simulated and real tumors with histology data containing homogeneous and heterogeneous activity distributions were used to assess the algorithm's accuracy. Results: The new 3-FLAB algorithm is able to extract the overall tumor from the background tissues and delineate variable uptake regions within the tumors, with higher accuracy and robustness compared with adaptive threshold (T{sub bckg}) and fuzzy C-means (FCM). 3-FLAB performed with a mean classification error of less than 9% +- 8% on the simulated tumors, whereas binary-only implementation led to errors of 15% +- 11%. T{sub bckg} and FCM led to mean errors of 20% +- 12% and 17% +- 14%, respectively. 3-FLAB also led to more robust estimation of the maximum diameters of tumors with histology measurements, with <6% standard deviation, whereas binary FLAB, T{sub bckg} and FCM lead to 10%, 12%, and 13%, respectively. Conclusion: These encouraging results warrant further investigation in future studies that will investigate the impact of 3-FLAB in radiotherapy treatment planning, diagnosis, and therapy response evaluation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Predicting Post-External Beam Radiation Therapy PSA Relapse of Prostate Cancer Using Pretreatment MRI

Purpose: To investigate whether pretreatment endorectal magnetic resonance imaging (MRI) findings can predict biochemical relapse in patients with clinically localized prostate cancer treated with external beam radiation therapy (EBRT). Methods and Materials: Between January 2000 and January 2002, 224 patients (median age, 69 years; age range, 45-82 years) with biopsy-proven prostate cancer underwent endorectal MRI before high-dose ({>=}81Gy) EBRT. The value of multiple clinical and MRI variables in predicting prostate-specific antigen (PSA) relapse at 5 years was determined by use of univariate and multivariate stepwise Cox regression. Clinical variables included pretreatment PSA, clinical T stage, Gleason score, use of neoadjuvant hormonal therapy, and radiation dose. Magnetic resonance imaging variables, derived from retrospective consensus readings by two radiologists, were used to measure intraprostatic and extraprostatic tumor burden. Results: After a median follow-up of 67 months, PSA relapse developed in 37 patients (16.5%). The significant predictors of PSA relapse on univariate analysis were pretreatment PSA, clinical T stage, and multiple MRI variables, including MRI TN stage score; extracapsular extension (ECE) status; number of sextants involved by ECE, all lesions, or index (dominant) lesion; apical involvement; and diameter and volume of index lesion. Pretreatment PSA and ECE status were the only significant independent predictors on multivariate analysis (p < 0.05 for both). Extracapsular extension status was associated with the highest hazard ratio, 3.04; 5-year PSA relapse rates were 7% for no ECE, 20% for unilateral ECE, and 48% for bilateral ECE. Conclusions: Magnetic resonance imaging findings can be used to predict post-EBRT PSA relapse, with ECE status on MRI and pretreatment PSA being significant independent predictors of this endpoint.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fractionated Stereotactic Radiotherapy in the Treatment of Vestibular Schwannoma (Acoustic Neuroma): Predicting the Risk of Hydrocephalus;Vestibular schwannoma; Hydrocephalus; Fractionated; Stereotactic radiotherapy

Purpose: To determine the incidence and predictive factors for the development of hydrocephalus in patients with acoustic neuromas (AN) treated with fractionated stereotactic radiotherapy. Patients and Methods: Seventy-two patients with AN were treated with fractionated stereotactic radiotherapy between 1998 and 2007 (45-50 Gy in 25-30 fractions over 5 to 6 weeks). The pretreatment MRI scan was assessed for tumor characteristics and anatomic distortion independently of subsequent outcome and correlated with the risk of hydrocephalus. Results: At a median follow-up of 49 months (range, 1-120 months), 5-year event-free survival was 95%. Eight patients (11%) developed hydrocephalus within 19 months of radiotherapy, which was successfully treated. On univariate analysis, pretreatment factors predictive of hydrocephalus were maximum diameter (p = 0.005), proximity to midline (p = 0.009), displacement of the fourth ventricle (p = 0.02), partial effacement of the fourth ventricle (p < 0.001), contact with the medulla (p = 0.005), and more brainstem structures (p = 0.004). On multivariate analysis, after adjusting for fourth ventricular effacement, no other variables remained independently associated with hydrocephalus formation. Conclusions: Fractionated stereotactic radiotherapy results in excellent tumor control of AN, albeit with a risk of developing hydrocephalus. Patients at high risk, identified as those with larger tumors with partial effacement of the fourth ventricle before treatment, should be monitored more closely during follow-up. It would also be preferable to offer treatment to patients with progressive AN while the risk of hydrocephalus is low, before the development of marked distortion of fourth ventricle before tumor diameter significantly exceeds 2 cm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Delineation of the Postprostatectomy Prostate Bed Using Computed Tomography: Interobserver Variability Following the EORTC Delineation Guidelines

Purpose: The present study aims to assess the interobserver agreement of prostate bed delineation after radical prostatectomy using CT alone as proposed by the European Organization for Research and Treatment of Cancer (EORTC) guidelines. Methods and Materials: Six observers delineated the postoperative prostate bed (PB) and the original seminal vesicle position or remnants (SV) of 10 patients according to the EORTC guidelines. Contours were then compared for agreement between observers (the apparent volume overlap and generalized kappa statistics). Standard deviations were also calculated to measure the variability of the position of the outer margins. Results: The mean volume of 100% agreement ({+-}1 standard deviation, SD) was only 5.0 ({+-}3.3) ml for the PB and 0.9 ({+-}1.5) ml for the SV, whereas the mean union of all contours ({+-}1 SD) was 41.1 ({+-}11.8) ml and 25.3 ({+-}13.4) ml, respectively. The mean overall agreement corrected for chance was moderate for both the PB (mean kappa, 0.49; range, 0.35-0.62) and SV (mean kappa, 0.42; range, 0.22-0.59). The overall SD of the outer margins of the PB ranged from 4.6 to 7.0 mm Conclusion: The delineation of the postprostatectomy bed using CT shows only a moderate observer agreement when following the EORTC guidelines.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reduced basis ANOVA methods for partial differential equations with high-dimensional random inputs

In this paper we present a reduced basis ANOVA approach for partial deferential equations (PDEs) with random inputs. The ANOVA method combined with stochastic collocation methods provides model reduction in high-dimensional parameter space through decomposing high-dimensional inputs into unions of low-dimensional inputs. In this work, to further reduce the computational cost, we investigate spatial low-rank structures in the ANOVA-collocation method, and develop efficient spatial model reduction techniques using hierarchically generated reduced bases. We present a general mathematical framework of the methodology, validate its accuracy and demonstrate its efficiency with numerical experiments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Active oversight and quality control in standard Bayesian optimization for autonomous experiments

The fusion of experimental automation and machine learning has catalyzed a new era in materials research, prominently featuring Gaussian Process (GP) Bayesian Optimization (BO) driven autonomous experiments. Here we introduce a Dual-GP approach that enhances traditional GPBO by adding a secondary surrogate model to dynamically constrain the experimental space based on real-time assessments of the raw experimental data. This Dual-GP approach enhances the optimization efficiency of traditional GPBO by isolating more promising space for BO sampling and more valuable experimental data for primary GP training. We also incorporate a flexible, human-in-the-loop intervention method in the Dual-GP workflow to adjust for unanticipated results. We demonstrate the effectiveness of the Dual-GP model with synthetic model data and implement this approach in autonomous pulsed laser deposition experimental data. This Dual-GP approach has broad applicability in diverse GPBO-driven experimental settings, providing a more adaptable and precise framework for refining autonomous experimentation for more efficient optimization.

36 MATERIALS SCIENCE↗

Gaussian-based techniques for quantum propagation from the time-dependent variational principle: Formulation in terms of trajectories of coupled classical and quantum variables

In this article, two coherent-state based methods of quantum propagation, namely, coupled coherent states (CCS) and Gaussian-based multiconfiguration time-dependent Hartree (G-MCTDH), are put on the same formal footing, using a derivation from a variational principle in Lagrangian form. By this approach, oscillations of the classical-like Gaussian parameters and oscillations of the quantum amplitudes are formally treated in an identical fashion. We also suggest a new approach denoted here as coupled coherent states trajectories (CCST), which completes the family of Gaussian-based methods. Using the same formalism for all related techniques allows their systematization and a straightforward comparison of their mathematical structure and cost.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A general few-projection method for tomographic reconstruction of samples consisting of several distinct materials

We present a method for tomographic reconstruction of objects containing several distinct materials, which is capable of accurately reconstructing a sample from vastly fewer angular projections than required by conventional algorithms. The algorithm is more general than many previous discrete tomography methods, as: (i) a priori knowledge of the exact number of materials is not required; (ii) the linear attenuation coefficient of each constituent material may assume a small range of a priori unknown values. We present reconstructions from an experimental x-ray computed tomography scan of cortical bone acquired at the SPring-8 synchrotron.

62 RADIOLOGY AND NUCLEAR MEDICINE↗