Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “magnetization measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Plasma, magnetic, and electromagnetic measurements at nonmagnetic bodies

The need to explore the magnetospheres of the Earth and the giant planets is widely recognized and is an integral part of our planetary exploration program. The equal need to explore the plasma, magnetic, and electromagnetic environments of the nonmagnetic bodies is not so widely appreciated. The previous, albeit incomplete, magnetic and electric field measurements at Venus, Mars, and comets have proven critical to our understanding of their atmospheres and ionospheres in areas ranging from planetary lightning to solar wind scavenging and accretion. In the cases of Venus and Mars, the ionospheres can provide communication paths over the horizon for low-altitude probes and landers, but we know little about their lower boundaries. The expected varying magnetic fields below these planetary ionospheres penetrates the planetary crusts and can be used to sound the electrical conductivity and the thermal profiles of the interiors. However, we have no knowledge of the levels of such fields, let alone their morphology. Finally, we note that the absence of an atmosphere and an ionosphere does not make an object any less interesting for the purposes of electromagnetic exploration. Even weak remanent magnetism such as that found on the Moon during the Apollo program provides insight into the present and past states of planetary interiors. We have very intriguing data from our space probes during times of both close and distant passages of asteroids that suggest they may have coherent magnetization. If true, this observation will put important constraints on how the asteroids formed and have evolved. Our planetary exploration program must exploit its full range of exploration tools if it is to characterize the bodies of the solar system thoroughly. We should especially take advantage of those techniques that are proven and require low mass, low power, and low telemetry rates to undertake.

Russell, C. T.↗

Measurements of extended magnetic fields in laser-solid interaction

Magnetic fields generated from a laser-foil interaction are measured with high fidelity using a proton radiography scheme with x-ray fiducials. In contrast to prior findings under similar experimental conditions, this technique reveals the self-generated, Biermann-battery fields extend beyond the edge of the expanding plasma plume to a radius of over 3.5 mm by t = + 1.4 ns. An analysis of two monoenergetic proton populations confirms that proton deflection is dominated by magnetic fields far from the interaction ( > 2 mm) and electric fields are insignificant. The results are not captured in state-of-the-art magnetohydrodynamics simulations and suggest the need to consider additional physics mechanisms for the magnetic field generation and transport in laser-solid interactions. Published by the American Physical Society 2024

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Radio frequency electrical resistance measurement under destructive pulsed magnetic fields

We developed a resistance measurement using radio frequency reflection to investigate the electrical transport characteristics under destructive pulsed magnetic fields above 100 T. A sample stage consisting of a homemade flexible printed circuit reduced the noise caused by the induced voltage from the pulsed magnetic fields, improving the accuracy of the measurements of the reflected waves. From the obtained reflectance data, the absolute value of the magnetoresistance was successfully determined by analyzing the phase with admittance charts. In conclusion, these developments enable more accurate and comprehensive measurements of electrical resistance in pulsed magnetic fields.

47 OTHER INSTRUMENTATION↗

On Alfvénic turbulence of solar wind streams observed by Solar Orbiter during March 2022 perihelion and their source regions

It has been recently accepted that the standard classification of the solar wind solely according to flow speed is outdated, and particular interest has been devoted to the study of the origin and evolution of so-called Alfvénic slow solar wind streams and to what extent such streams resemble or differ from fast wind. In March 2022, Solar Orbiter completed its first nominal phase perihelion passage. During this interval, it observed several Alfvénic streams, allowing for characterization of fluctuations in three slow wind intervals (AS1-AS3) and comparison with a fast wind stream (F) at almost the same heliocentric distance. This work makes use of Solar Orbiter plasma parameters from the Solar Wind Analyzer (SWA) and magnetic field measurements from the magnetometer (MAG). The magnetic connectivity to the solar sources of selected solar wind intervals was reconstructed using a ballistic extrapolation based on measured solar wind speed down to the (spherical) source surface at 2.5 R s below which a potential field extrapolation was used to map back to the Sun. The source regions were identified using SDO/AIA observations. A spectral analysis of in situ measured magnetic field and velocity fluctuations was performed to characterize correlations, Alfvénicity, normalized cross-helicity, and residual energy in the frequency domain as well as intermittency of the fluctuations and spectral energy transfer rate estimated via mixed third-order moments. A machine learning technique was used to separate proton core, proton beam, and alpha particles and to study v − b correlations for the different ion populations in order to evaluate the role played by each population in determining the Alfvénic content of solar wind fluctuations. The comparison between fast wind and Alfvénic slow wind intervals highlights the differences between the two solar wind regimes: The fast wind is characterized by larger amplitude fluctuations, and magnetic and velocity fluctuations are closer to equipartition of energy. In fact the Alfvénic slow wind streams appear to be on a spectrum of wind types, with AS1, originating from open field lines neighboring active regions and displaying similarities with the fast wind in terms of fluctuation amplitude and turbulence characteristics, but not with respect to the alpha particles and proton beams. The other two slow streams differed both in their sources as well as plasma characteristics, with AS2 coming from the expansion of a narrow coronal hole corridor and AS3 from a region straddling a pseudostreamer. The latter displayed the coldest and highest density but the slowest stream with the smallest fluctuation amplitude and greatest magnetic energy excess. It also showed the largest scatter in proton beam speeds and the greatest difference in speed between proton beam and alpha particles. This study shows how the old fast–slow solar wind dichotomy, already called into question by the observations of slower Alfvénic solar wind streams, should further be refined, as the Alfvénic slow wind, originating in different solar wind regions, show significant differences in density, temperature, and proton and alpha-particle properties in the inner heliosphere. The observations presented here provide the starting point for a better understanding of the origin and evolution of different solar wind streams as well as the evolving turbulence contained within.

magnetohydrodynamics (MHD)↗

Magnetic Field Response Measurement Acquisition System

This paper presents a measurement acquisition method that alleviates many shortcomings of traditional measurement systems. The shortcomings are a finite number of measurement channels, weight penalty associated with measurements, electrical arcing, wire degradations due to wear or chemical decay and the logistics needed to add new sensors. Wire degradation has resulted in aircraft fatalities and critical space launches being delayed. The key to this method is the use of sensors designed as passive inductor-capacitor circuits that produce magnetic field responses. The response attributes correspond to states of physical properties for which the sensors measure. Power is wirelessly provided to the sensing element by using Faraday induction. A radio frequency antenna produces a time-varying magnetic field used to power the sensor and receive the magnetic field response of the sensor. An interrogation system for discerning changes in the sensor response frequency, resistance and amplitude has been developed and is presented herein. Multiple sensors can be interrogated using this method. The method eliminates the need for a data acquisition channel dedicated to each sensor. The method does not require the sensors to be near the acquisition hardware. Methods of developing magnetic field response sensors and the influence of key parameters on measurement acquisition are discussed. Examples of magnetic field response sensors and the respective measurement characterizations are presented. Implementation of this method on an aerospace system is discussed.

Woodard, Stanley E.↗

Magnetic properties of Tm 3+ in layered triangular lattices

Rare-earth chalcogenides, ARCh 2 (A = alkali metal or monovalent ion; R = rare-earth elements; Ch = O, S, and Se), have been identified as promising candidates for exploring a variety of novel frustrated quantum magnetic phenomena. Tm-based series, ATmCh 2 , where Tm 3+ ions are arranged on various frustrated geometric lattices, provide a platform for investigating the competitions among spin–orbit coupling, crystal field effects, and magnetic exchange interactions in the context of geometric frustration. In this study, we present how the crystallographic structures of newly synthesized ATmSe 2 (A = Li and Na) influence their frustrated magnetic behaviors. Both NaTmSe 2 and LiTmSe 2 adopt a delafossite-type structure with a two-dimensional (2D) triangular lattice, but LiTmSe 2 has a much shorter c-axis parameter compared to this in NaTmSe 2 . Both heat capacity and magnetic susceptibility measurements confirm the absence of long-range magnetic order in either compound. However, magnetic measurements data reveals the differences in magnetic interactions: NaTmSe 2 exhibits features of low-dimensional magnetism, likely driven by its layered crystal structure, compared to LiTmSe 2 .

Crystal field theory↗

Coordinated ionospheric and magnetospheric observations from the ISIS 2 satellite by the ISIS 2 experimenters. Volume 2: Auroral optical emissions magnetic field perturbations, and plasma characteristics, measured simultaneously on the same magnetic field line

The data set consists of a selected number of passes, each comprising a format combination that is most appropriate for the particular data set. A list of ISIS 2 experimenters, with addresses and telephone numbers is included. A brief description of the ISIS 2 satellite is given, followed by more detailed instrument descriptions, format descriptions, data set descriptions, and the data themselves.

Shepherd, G. G.↗

Using magnetic dynamics to measure the spin gap in a candidate Kitaev material

Spin-orbit entangled materials have attracted widespread interest due to the novel magnetic phenomena arising from the interplay between spin-orbit coupling and electronic correlations. However, the intricate nature of spin interactions within Kiteav materials complicates the precise measurement of low-energy spin excitations. Using Na 2 Co 2 TeO 6 as an example, we study these low-energy spin excitations using the time-resolved resonant elastic x-ray scattering (tr-REXS). Our observations unveil remarkably slow spin dynamics at the magnetic peak, whose recovery timescale is several nanoseconds. This timescale aligns with the extrapolated spin gap of ~1 μeV, obtained by density matrix renormalization group (DMRG) simulations in the thermodynamic limit. The consistency demonstrates the efficacy of tr-REXS in discerning low-energy spin gaps inaccessible to conventional spectroscopic techniques.

36 MATERIALS SCIENCE↗

Magnetic Field Response Measurement Acquisition System

A measurement acquisition method that alleviates many shortcomings of traditional measurement systems is presented in this paper. The shortcomings are a finite number of measurement channels, weight penalty associated with measurements, electrical arcing, wire degradations due to wear or chemical decay and the logistics needed to add new sensors. The key to this method is the use of sensors designed as passive inductor-capacitor circuits that produce magnetic field responses. The response attributes correspond to states of physical properties for which the sensors measure. A radio frequency antenna produces a time-varying magnetic field used to power the sensor and receive the magnetic field response of the sensor. An interrogation system for discerning changes in the sensor response is presented herein. Multiple sensors can be interrogated using this method. The method eliminates the need for a data acquisition channel dedicated to each sensor. Methods of developing magnetic field response sensors and the influence of key parameters on measurement acquisition are discussed.

Woodard, Stanley E.↗

A New Plasma Radar Concept for Simultaneous Magnetic and Density Measurements

An innovative, compact 288GHz interferometer has been fabricated, tested, installed and successfully demonstrated on the LAPD-U magnetized plasma at UCLA. The system takes advantage of frequency modulated (FM) radar techniques to deliver a compact heterodyne system. In addition, the reflected power from the source is taken advantage of to eliminate the need for additional quasi-optical components. Electron density in LAPD-U plasma has recently been increased substantially thereby requiring a higher frequency/shorter wavelength interferometer to avoid deleterious refractive effects. This system satisfies those needs. The system uses a 96GHz varactor tuned Gunn oscillator which passes to a passive tripler. This tripler has ~3% conversion efficiency. The 288GHz radiation is then coupled to free space using a so-called dual-mode or Pickett horn. The output 288GHz beam is then coupled to an aspheric lens manufactured from low-loss, high-density polyethylene. This lens is employed to collimate the emerging beam. Small axial adjustment of the lens position can also be used to create a slowly focusing beam so as to optimize the measured signal. In addition, up-down or side-to-side adjustment of the lens can be utilized to steer the beam vertically or horizontally – again to optimize alignment. The propagating beam passes through a beam splitter and then through a water-free, bubble-free fused quartz window into the LAPD-U vacuum vessel. The beam-splitter is a thin sheet of G10 which reflects a small fraction of the incident power (~5 %) towards a zero-bias detector optimized for the frequency range from 220 to 300GHz. Note that waveguides at this frequency have dimensions of ~0.9mm x 0.45mm and so have very large conductive losses. This drives the use of quasi-optical propagation. The detector requires no DC bias and is very responsive (> 1V/mW into 1MΩ). Radiation is coupled to the detector via a similar lens-horn arrangement used for the launch. This reflected beam acts as the local oscillator or reference millimeter-wave beam for the detector. The remainder of the launched source beam then enters the LAPD-U vacuum vessel and passes through the plasma at the mid-plane until reaching the opposing port which is closed off with an aluminum flange. This flange is used as a mirror to retroreflect the incident 288GHz beam back along its path. The retroreflected beam exits the input port but does NOT couple directly into the zero-bias detector. Instead, the majority of the return power continues towards the 288GHz source. As mentioned above the transmitted beam enters the source a second time. This would appear undesirable. However, at these frequencies multipliers are highly non-linear elements which results in a significant portion of the return beam (~20%) re-emerging from the multiplier and horn and then coupling via the G10 beam-splitter to the zero-bias detector. This approach eliminated the need for a second quasi-optical beam-splitter. The system is extremely compact measuring approximately 28 inches x 20 inches. The above did not explain how heterodyne operation was achieved. As mentioned above the Gunn oscillator is able to be varactor tuned. This allows a low voltage to be applied to control the operating frequency of the Gunn oscillator. During heterodyne operation a sawtooth shaped voltage is applied to the varactor at 750kHz using an 80MHz Arbitrary Waveform Generator (AWG). This voltage changes the Gunn frequency linearly during the up-sweep which is then reset abruptly at the sawtooth crash to be immediately followed by another linear sweep. Passage through the 288GHz multiplier triples the frequency change experienced by the electromagnetic wave. These frequency changes are small – tens of megahertz. This FM radar approach results in the launched electromagnetic wave frequencies at the detector for the reference and plasma wave to be different. The approximately 10 ns delay propagation delay for the plasma beam results in the local oscillator and plasma beams NOT having an identical frequency – there is in fact a fixed difference frequency. The frequency tuning level of the Gunn oscillator is then adjusted so that there is ONE cycle of this difference frequency during each linear ramp. During the sawtooth crash or downward re-sweep this one cycle replays in reverse but on a very fast timescale. The process then repeats. Low-pass filtering eliminates the fast re-sweep to leave a pure sine wave heterodyne signal. When the plasma is present it introduces a phase delay in the sine wave (caused by the extremely small Doppler shift resulting from the optical path length change). Of course, to measure this phase change we need a reference. This is simply obtained from an arbitrary waveform generator which provides a synchronized output pulse train which again is low pass filtered to obtain a 750kHz sinusoidal voltage reference for the interferometer. The interferometer was installed on LAPD-U where it has worked reliably and has established that electron densities exceeding 1x10 13 cm -3 are routinely achieved. In addition, the system sensitivity was able to easily observe density fluctuation at frequencies up to 50kHz. FM Radar techniques have enabled a full demonstration of a compact, sensitive, high frequency (288GHz/1mm) heterodyne interferometer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

AC resistance measurement of Skew Quadrupole Magnet

This tech note exhibits AC resistance measurement system of the Skew Quadrupole magnet with and without a beam pipe used in the AGS ring. The measurement results are compared with a system that uses skew quad power supply for the magnet. An introduction to ac resistance conceptualization and modeling is presented. It is followed by measurement methodology used and the results.

43 PARTICLE ACCELERATORS↗

Emergence of Local Magnetic Moment in Ternary TaWSe 2 Single Crystal via Atomic Clustering

Ternary transition metal dichalcogenides (TMDs) provide a versatile platform to explore novel electronic and magnetic ground states via compositional substitution and local structural modulations. Using a combination of scanning tunneling microscopy and spectroscopy (STM/S), magnetic property measurements, and density functional theory (DFT) calculations, the emergence of local magnetic moments driven by the clustering of Ta atoms in ternary TaWSe 2 single crystals is analyzed. STM topography reveals triangular clusters of Ta atoms embedded within W-rich regions of TaWSe 2 . These clusters exhibit a consistent shape and an orderly arrangement throughout the surfaces. DFT calculations show that these Ta clusters induce local strain, giving rise to localized magnetic moments. The magnetic behavior is further corroborated by temperature-dependent magnetization measurements, which exhibit a magnetic anomaly at ∼50 K. In conclusion, this study offers a pathway to engineer magnetism in TMD systems with potential applications in spintronic and quantum materials.

DFT↗

Advanced flip-coil system for magnetic field integral measurements of insertion devices

A novel flip-coil measurement system has been developed for the National Synchrotron Light Source II (NSLS-II) at Brookhaven National Laboratory. This paper describes the design, implementation, and commissioning of the new measurement bench, highlighting its key features, including improved mechanical stability, advanced data acquisition, and enhanced reproducibility. The system enables precise characterization of field integrals and multipole components, ensuring the optimal performance of Insertion Devices (IDs) before installation in the NSLS-II storage ring. The flip-coil system incorporates an innovative approach to minimize mechanical and electrical errors, which significantly improves the reproducibility of measurements. In addition, the system features a state-of-the-art data acquisition system that enables real-time monitoring and analysis, further enhancing the efficiency and accuracy of the measurement process. Furthermore, preliminary tests have demonstrated that the new system meets the stringent requirements for magnetic field characterization of advanced insertion devices, making it an essential tool for future ID commissioning and quality assurance at NSLS-II.

36 MATERIALS SCIENCE↗

Measuring the Muon Neutrino Magnetic Moment in the NOvA Near Detector

Measuring an enhanced neutrino magnetic moment would be a clear indication of physics beyond the Standard Model, shedding light on the correct beyond Standard Model theory or the potential Majorana nature of neutrinos. It would manifest in the NOvA near detector as an excess of neutrino-on-electron elastic scattering interactions at low electron recoil energies. Leveraging an intense and highly pure muon neutrino beam, along with a finely segmented liquid scintillator detector technology specifically designed for electromagnetic shower separation, enables NOvA to achieve a potentially world-leading sensitivity in probing the effective muon neutrino magnetic moment. This analysis, based on neutrino data collected between 2014 and 2021, corresponding to an exposure of $13.8\times10^{20}$ protons-on-target, yields a result consistent with the Standard Model-only hypothesis with a p-value of 0.31. An upper limit on the effective muon neutrino magnetic moment is set at $\mu_{\nu_\mu}<19.1\times 10^{-10}\mu_B$ at $90\%$ confidence level. Despite facing statistical limitations stemming from low cross section of the signal process, systematic uncertainties have a significant impact on this result. To address these challenges, the NOvA Test Beam experiment focuses on mitigating some of the largest systematic uncertainties within NOvA by investigating particle interactions and energy deposition in a small-scale replica NOvA detector. This thesis describes the calibration of the NOvA Test Beam detector, which is a crucial step in analysing the Test Beam data before they can be utilised to reduce NOvA systematic uncertainties.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Magnetization and magnetic entropy of Dy2Ti2O7

Isothermal measurements of the magnetic entropy, magnetization, and differential susceptibility of Dy2Ti2O7 have been made. Absolute values of magnetic entropy have been determined as a function of applied magnetic field for several temperatures in the range 2-20 K, and several isofield lines in the magnetic entropy-temperature plane have been determined. Magnetization measurements, which extended into the saturation region, yield a powder-average magnetic moment of about 4.7 Bohr magnetons per ion. A van Vleck contribution to M was also observed. The results are consistent with the assumption of a nearly pure Jz equals + or - 15/2 ground-state Kramers doublet for the Dy(+++) ion. Comments on the suitability of Dy2Ti2O7 for use in a magnetic refrigerator cycling between 4.2 and 20 K are included.

Flood, D. J.↗

High fidelity simulations of contaminant dispersion in an urban environment with comparison to magnetic resonance imaging measurements

The dispersion of a contaminant in an urban environment has the potential to impact a large population of people. In this work, a complex urban canopy flow based on the Oklahoma City downtown business district circa 2003 is studied using Magnetic Resonance Imaging (MRI) and high-fidelity Large Eddy Simulations (LES). MRI is a novel experimental technique that can provide high-resolution measurements in four dimensions (three spatial and temporal) for lab scale models. The experiments and simulations use the same geometry and boundary conditions providing a one-to-one comparison of the two methods. Results are presented on the time-averaged velocity and concentration fields, the temporal dynamics of the concentration plumes for a transient release, and a novel Cloud Identification Algorithm that can separate plumes produced by periodic contaminant releases used for ensemble averaging over many releases. The MRI and LES datasets both include millions of measurement voxels and the comparisons highlight the complex 3D nature of the flow including strong vertical velocities in spanwise street canyons and flow acceleration in streamwise street canyons. The concentration fields are qualitatively similar albeit the LES shows larger dispersion. A quantitative analysis with performance measures compares the datasets pointwise and demonstrates that the two 3D datasets are similar with respect to many measures including a fractional bias of 0.02 (ideal=0.0), correlation coefficient of 0.87 (ideal = 1.0), and the fraction points within a factor of 2 is 0.98 (ideal = 1.0). Plume analysis compares the arrival and residence time of contaminant and is found to vary significantly with location within the urban environment with arrival times between 0 and 1.25 and differences within the contaminant cloud less than 10% at most locations.

54 ENVIRONMENTAL SCIENCES↗

Properties of Cosmic Lithium Isotopes Measured by the Alpha Magnetic Spectrometer

We present the first measurement of cosmic-ray fluxes of 6 Li and 7 Li isotopes in the rigidity range from 1.9 to 25 GV. The measurements are based on 9.7 × 10 5 6 Li and 1.04 × 10 6 7 Li nuclei collected by the Alpha Magnetic Spectrometer on the International Space Station from May 2011 to October 2023. We observe that over the entire rigidity range the 6 Li and 7 Li fluxes exhibit nearly identical time variations and, above ∼4 GV, the time variations of 6 Li , 7 Li , He, Be, B, C, N, and O fluxes are identical. Above ∼7 GV, we find an identical rigidity dependence of the 6 Li and 7 Li fluxes. This shows that they are both produced by collisions of heavier cosmic-ray nuclei with the interstellar medium and, in particular, excludes the existence of a sizable primary component in the 7 Li flux.

cosmic ray acceleration↗

The magnetosphere of Saturn

Pioneer 11 and Voyager 1 and 2 magnetic field measurements over the entire flyby of Saturn's magnetic field have been analyzed by fitting a magnetospheric dipole field (i.e., a dipole field plus the field due to currents in the magnetopause), higher moments of the internal field aligned with the dipole along the rotation axis, and the field due to an equatorial sheet current to the magnetic measurements. A dipole moment of 21,431 nT R(s) exp 3, a quadrupole moment of 2403 nT R(s) exp 4, an octopole moment of 2173 nT R(s) exp 5, and an equatorial sheet current of half thickness 2.0 R(s) from about 5 R(s) to the solar edge of the magnetopause, fit the measurements over the entire magnetosphere with an rms deviation of 3.2 nT where R(s) is the planet radius, 66,330 km. The primary feature of the present analysis is the explicit inclusion of the calculated magnetopause current field, which reduces the overall rms deviation over the entire flyby from sigma values of 4.7 and 5.9 nT, using previous models, to 3.2 nT using the present.

Beard, David B.↗