Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load management”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Uncertainty characterization in a coupled human-natural system: Modeling agricultural adaptation in the Great Lakes Region

The Great Lakes Region's water quality and ecological health are threatened by the export of nutrients from agricultural lands, which causes eutrophication, hypoxia, and destructive algal blooms. The intensification of hydrologic cycles brought about by climate change is expected to exacerbate nutrient loading in the region, and, at the same time, agricultural adaptation to changing conditions is also expected to affect loading through shifting amounts and timing of fertilization. Quantifying these future effects and their interactions necessitates modeling both the human and natural processes as a coupled system, by pairing land use and agricultural management with hydrologic modeling. At the same time, compounding uncertainties arising from the complex interactions in both systems significantly limit our predictive understanding of the region's impacts. This study utilizes the Soil and Water Assessment Tool (SWAT), developed for simulating the impact of various farmer decisions on watershed functions in Western Lake Erie watersheds, and an under-development agent-based model (ABM) for agricultural management decisions. The aim of this study is to use global sensitivity analysis on the coupled ABM and SWAT models to quantify how uncertainty in both models interactively affects nutrient loading. To do so, we will conduct Sobol sensitivity analysis experiments at different levels of coupling assumptions to quantify how various uncertain factors (e.g., soil moisture and crop choice) and their interactions affect our estimates of nutrient loading. The results of this analysis will allow us to quantify how complex interactions and dependencies between both systems amplify the effect of uncertainties. Insights gained from this study will have broader implications for modeling the adaptive co-evolution of human and natural systems under climate change and can inform effective management of nutrient loading in the Great Lakes Region.

Climate Change↗

Energy-Efficient Management of Mechanical Ventilation and Relative Humidity in Hot-Humid Climates

In hot and humid climates, it is challenging to energy-efficiently maintain indoor RH at acceptable levels while simultaneously providing required ventilation, particularly in high performance low cooling load homes. The fundamental problem with solely relying on fixed capacity central cooling systems to manage moisture during low sensible load periods is that they are oversized for cooler periods of the year despite being 'properly sized' for a very hot design cooling day. The primary goals of this project were to determine the impact of supplementing a central space conditioning system with 1) a supplemental dehumidifier and 2) a ductless mini-split on seasonal energy use and summer peak power use as well as the impact on thermal distribution and humidity control inside a completely furnished lab home that was continuously ventilated in accordance with ASHRAE 62.2-2013.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy-Efficient Management of Mechanical Ventilation and Relative Humidity in Hot-Humid Climates

In hot and humid climates, it is challenging to energy-efficiently maintain indoor RH at acceptable levels while simultaneously providing required ventilation, particularly in high performance low cooling load homes. The fundamental problem with solely relying on fixed capacity central cooling systems to manage moisture during low sensible load periods is that they are oversized for cooler periods of the year despite being 'properly sized' for a very hot design cooling day. The primary goals of this project were to determine the impact of supplementing a central space conditioning system with 1) a supplemental dehumidifier and 2) a ductless mini-split on seasonal energy use and summer peak power use as well as the impact on thermal distribution and humidity control inside a completely furnished lab home that was continuously ventilated in accordance with ASHRAE 62.2-2013.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Fuzzy-Logic Subsumption Controller for Home Energy Management Systems

Presentation for NAPS 2015 associated with conference publication CP-64392. Home Energy Management Systems (HEMS) are controllers that manage and coordinate the generation, storage, and loads in a home. These controllers are increasingly necessary to ensure that increasing penetrations of distributed energy resources are used effectively and do not disrupt the operation of the grid. In this paper, we propose a novel approach to HEMS design based on behavioral control methods, which do not require accurate models or predictions and are very responsive to changing conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

DOE Standard Canister Loading Methodology Poster

Over 250 different types of spent nuclear fuel (SNF) are managed by the U.S. Department of Energy (DOE) at the Idaho National Laboratory (INL). The current configuration of SNF at INL is not transportable off-site. In the Yucca Mountain Repository License Application, the SNF was to be loaded into DOE Standard Canisters which are capable of storage, transportation, and eventual disposal using the proper overpacks. The DOE Standard Canister will allow INL to place the SNF in a Road-Ready configuration in preparation for transportation off-site. The focus of this work is development of a general loading methodology for the DOE Standard Canister. This methodology is to be general enough that it will apply to all SNF to be loaded into the DOE Standard Canister. The main sections of the methodology to be outlined are prerequisites before loading (including any issues with materials such as inserts or baskets), loading of SNF, and canister closure and quality assurance (including welding and inspection). Each subsection will analyze and provide the bases for each step.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Characterizing Electric Grid System Benefits of MPC-Based Residential Load Shaping: Preprint

Routinely encouraging and discouraging residential electric load throughout the day will be increasingly critical in efficiently managing the smart grid to reliably deliver clean, low-cost electricity. Yet, manipulating the duty cycles of thermostatically controlled loads such as heating, air conditioning, and hot water heaters can have the effect of destabilizing or stabilizing the grid. This work explores the potential for price-responsive control of residential air conditioning to shape electric demand at the distribution feeder level to minimize electricity production costs. Physical models of the interplay between building thermal and electric loads are used to Simulate time-series temperature and load behavior. Instantaneous load-adding and load-shedding opportunities are quantified in more than 100,000 individual homes on 204 distribution feeders with results presented for 35 cities across the United States. In the context of distributed model predictive control, simulation of feeder-level response to a residential day-ahead 5-minute pricing vector to 2,146 homes highlights an aggregate impact of flexible loads.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Building America Case Study: Energy Efficient Management of Mechanical Ventilation and Relative Humidity in Hot-Humid Climates, Cocoa, Florida

In hot and humid climates, it is challenging to energy-efficiently maintain indoor RH at acceptable levels while simultaneously providing required ventilation, particularly in high performance low cooling load homes. The fundamental problem with solely relying on fixed capacity central cooling systems to manage moisture during low sensible load periods is that they are oversized for cooler periods of the year despite being 'properly sized' for a very hot design cooling day. The primary goals of this project were to determine the impact of supplementing a central space conditioning system with 1) a supplemental dehumidifier and 2) a ductless mini-split on seasonal energy use and summer peak power use as well as the impact on thermal distribution and humidity control inside a completely furnished lab home that was continuously ventilated in accordance with ASHRAE 62.2-2013.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Used Fuel Dry Storage Systems and Components for Shutdown Plants to Expedite Defueling of Spent Fuel Pool - 18378

For plants that have announced plans to shut down, their main priority is to off-load the Used Nuclear Fuel from the spent fuel pool to dry storage at an ISFSI so that they can proceed to 'Safe store' or other storage options, and start their decommissioning process as soon as possible. One of the major expenses for a decommissioned plant is the cost of maintenance of the spent fuel pool. Therefore, the ability of the dry storage system to store short cooled fuel is an important aspect of dry storage system for shutdown plants. When a shutdown plant evaluates the dry storage options, total cost of the transferring the fuel from the pool to ISFSI site needs to be evaluated. One of the major costs to the utility for dry storage is the cost of ISFSI pad (basemat) along with the cost of dry storage system hardware. Smaller ISFSI footprint saves utility for the cost of ISFSI site excavation, cost of engineered backfill and cost of ISFSI pad. In order to minimize the cost of dry storage systems, besides the size of the ISFSI pad as described above, other important considerations is to use high capacity systems. The highest capacity systems available in the dry storage market today are with 37 PWR or 89 BWR used fuel assemblies per canister. These dry storage systems are expected to be at the plant sites for extended duration due to the unavailability of Interim Storage Facilities or a permanent disposal sites like Yucca Mountain. Maintaining the integrity of the dry storage systems canisters and storage overpack so that they can safely protect the fuel and integrity of used nuclear fuel is maintained during storage period is of utmost importance. Robust Aging Management Program is an important aspect for dry storage systems not only at the shutdown plants but also at the operating plants. This paper will provide the update of a reduced footprint version of TN Americas NUHOMS{sup R} System with MATRIX HSM and NUHOMS{sup R} EOS Canisters that addresses the need for maximizing safety, ISFSI capacity while optimizing cost. It will provide an update on the current capabilities, design features and current status of the licensing and deployment of NUHOMS{sup R} EOS System. It will provide the current status of the MATRIX HSM along with the significant enhancement included for a robust Canister Evolved Safety Program for Aging Management. It will also describe the construction sequence; loading operations, and inspections during extended storage as a part of aging management program. The compact version of TN Americas NUHOMS{sup R} System with MATRIX HSM offers a 'Universal' Storage Overpack which is designed to accept all different designs dry storage canisters available in the industry. As UNF storage continues to drives the industry towards innovations that address the need for optimized dry storage systems, compact ISFSIs and prudent aging management programs, this new evolution of the TN Americas NUHOMS{sup R} system with MATRIX HSM and EOS Canisters offers a significant leap forward in addressing all of these challenges. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fuzzy-Logic Subsumption Controller for Home Energy Management Systems

Home Energy Management Systems (HEMS) are controllers that manage and coordinate the generation, storage, and loads in a home. These controllers are increasingly necessary to ensure that increasing penetrations of distributed energy resources are used effectively and do not disrupt the operation of the grid. In this paper, we propose a novel approach to HEMS design based on behavioral control methods, which do not require accurate models or predictions and are very responsive to changing conditions. We develop a proof-of-concept behavioral HEMS controller and show by simulation on an example home energy system that it capable of making context-dependent tradeoffs between goals under challenging conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Data analytics and optimization of an ice-based energy storage system for commercial buildings

Ice-based thermal energy storage (TES) systems can shift peak cooling demand and reduce operational energy costs (with time-of-use rates) in commercial buildings. The accurate prediction of the cooling load, and the optimal control strategy for managing the charging and discharging of a TES system, are two critical elements to improving system performance and achieving energy cost savings. This study utilizes data-driven analytics and modeling to holistically understand the operation of an ice–based TES system in a shopping mall, calculating the system’s performance using actual measured data from installed meters and sensors. Results show that there is significant savings potential when the current operating strategy is improved by appropriately scheduling the operation of each piece of equipment of the TES system, as well as by determining the amount of charging and discharging for each day. A novel optimal control strategy, determined by an optimization algorithm of Sequential Quadratic Programming, was developed to minimize the TES system’s operating costs. Three heuristic strategies were also investigated for comparison with our proposed strategy, and the results demonstrate the superiority of our method to the heuristic strategies in terms of total energy cost savings. Specifically, the optimal strategy yields energy costs of up to 11.3% per day and 9.3% per month compared with current operational strategies. A one-day-ahead hourly load prediction was also developed using machine learning algorithms, which facilitates the adoption of the developed data analytics and optimization of the control strategy in a real TES system operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

SWIM: A Switch Manager for Datacenter Networks

As modern datacenter networks (DCNs) grow to support hundreds of thousands of servers and beyond, managing network equipment - such as routers, firewalls, and load balancers - becomes increasingly complex. Network attributes such as IP address allocations and BGP neighbor relations are scattered among various network engineering groups, which makes troubleshooting the network a cumbersome task. In addition, network vendor diversity leads to an explosion of vendor-specific management systems or single-use automation scripts, limiting network scalability while increasing the time required to perform management tasks. In this article, the authors propose a unified network management system, Switch Manager (SWIM), to cope with the growth by standardizing the language for describing network attributes and unifying the interface for executing management actions on the network equipment.

97 MATHEMATICS AND COMPUTING↗

Accessory Hybridization for Medium- and Heavy-Duty Trucks

Manufacturers of medium- and heavy-duty engines and transmissions continually try to improve the efficiency of their components; however, it is becoming more difficult and costly to improve those technologies, and a new approach is needed to find efficiency gains in other vehicle systems. For example, most ancillary loads on the engines in medium- and heavy-duty trucks, both at idle and under driving conditions, are generated by accessories that are designed to address worst-case scenarios or to meet the minimum requirements at one operating point. Improvements to those systems would improve overall powertrain efficiency. The objectives of this cooperative research and development agreement (CRADA) between Oak Ridge National Laboratory (ORNL) and Cummins Inc. (CRADA No. NFE-13-04402) are (1) to analytically verify novel accessory electrification /hybridization approaches for medium- and heavy-duty trucks and (2) to experimentally validate prototype hardware utilizing the ORNL Vehicle Systems Integration Laboratory and the Cummins T112 test vehicle. Hybrid powertrains can provide significant reductions in fuel consumption, criteria pollutants, and greenhouse gas emissions. They provide these benefits by meeting vehicle power requirements in more flexible and optimal ways than a conventional powertrain (e.g., capture and use of braking energy, optimization of engine and component operation). Realizing the full potential of hybridization requires management of all vehicle power demands, including accessory loads. One of the major petroleum-reduction opportunities of hybridization is to shut the engine down when power demand is low. However, accessory loads, such as power steering, braking, climate control, and other electric auxiliaries, must still be managed when the engine is off.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modeling Savings for ENERGY STAR Smart Home Energy Management Systems

The objective of this study was to develop a repeatable and defensible methodology to analyze the energy savings for Home Energy Management Systems (HEMS) that meets the minimum requirements for certification under ENERGY STAR ® Smart Home Energy Management System (SHEMS) Version 1. Mandatory connected loads include a smart thermostat, two smart lights, and one smart power strip or smart outlet. Control strategies must include feedback to occupants through an in-home display, user programming, occupancy sensor-based controls, and responsiveness to utility signals such as demand response programs. Several occupant behavior patterns were selected to quantify the range of energy savings potential for a HEMS with this basic functionality. A literature review was conducted to establish realistic room-by-room occupancy levels and usage patterns for connected devices. A series of event-driven hourly profiles were created, followed by adjustments based on application of HEMS control strategies to thermostats, interior lighting, and plug load schedules. EnergyPlus modeling was performed using these hourly schedules in three locations (Boston, Houston, and Phoenix) to examine climate dependence of energy savings. Total site energy savings ranged from 4.3 to 27.1 MBtu/year (7%-35%), and utility bill savings ranged from $\$$123 to $\$$670/year (6%-29%). The highest predicted savings was realized by occupants that were not energy conscious prior to HEMS installation, but highly engaged with the HEMS controls once the system was installed. The smart thermostat accounted for most of the savings, followed by the smart power strip. Smart lighting did not save a significant amount of energy in our analysis, based on an assumption that efficient LEDs with no standby power would normally be installed anyway.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integrated Vehicle Thermal Management for Advanced Vehicle Propulsion Technologies

A critical element to the success of new propulsion technologies that enable reductions in fuel use is the integration of component thermal management technologies within a viable vehicle package. Vehicle operation requires vehicle thermal management systems capable of balancing the needs of multiple vehicle systems that may require heat for operation, require cooling to reject heat, or require operation within specified temperature ranges. As vehicle propulsion transitions away from a single form of vehicle propulsion based solely on conventional internal combustion engines (ICEs) toward a wider array of choices including more electrically dominant systems such as plug-in hybrid electric vehicles (PHEVs), new challenges arise associated with vehicle thermal management. As the number of components that require active thermal management increase, so do the costs in terms of dollars, weight, and size. Integrated vehicle thermal management is one pathway to address the cost, weight, and size challenges. The integration of the power electronics and electric machine (PEEM) thermal management with other existing vehicle systems is one path for reducing the cost of electric drive systems. This work demonstrates techniques for evaluating and quantifying the integrated transient and continuous heat loads of combined systems incorporating electric drive systems that operate primarily under transient duty cycles, but the approach can be extended to include additional steady-state duty cycles typical for designing vehicle thermal management systems of conventional vehicles. The work compares opportunities to create an integrated low temperature coolant loop combining the power electronics and electric machine with the air conditioning system in contrast to a high temperature system integrated with the ICE cooling system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Management of Risk and Uncertainty Through Optimized Co-Operation of Transmission Systems and Microgrids with Responsive Loads (Final Report)

The evolution of the power system to the reliable, efficient and sustainable system of the future will involve development of both demand- and supply-side technology and operations. Ambitious national and state-level goals around the decarbonization of electricity relies on the integration of very high levels of renewable resources, most of which are variable and intermittent. The use of demand response is an ideal approach to counterbalance the intermittency of renewable generation and brings the consumer into the spotlight. Until recently, very little research had been conducted on the co-optimization of these two systems due to computational limitations. However, advances in computational capabilities, and the judicious use of decomposition methods and innovative approximation methods for high-dimension dynamic programming made this goal a viable objective for this project, leading to a fundamental shift in the ability to integrate and fully utilize demand-side resources. To this end, the modeling framework developed introduces a novel co-optimization framework, to include the operations of both the transmission and distribution systems (or microgrids) in operational decision making. This framework was used to analyze renewable and distributed generation along with responsive demand and to compare the capability of co-optimized systems to perform with higher levels of variable renewables. Results show that the use of a bi-level optimization approach is an appropriate structure, capable of co-optimizing a transmission system with multiple distribution systems and microgrids. While increasing the number of connected systems provides increasing flexibility for renewables integration this can also the economic benefits to the low-voltage subsystems with each additional system connected. Comparison of a traditional single-level decision structure with the co-optimization approach illustrates a reduction in overall system cost under co-optimization, while specific cost allocations to transmission and distribution systems are changed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Exploring Effective Best Management Practices in the Miyun Reservoir Watershed, China

Miyun reservoir watershed is a major source of drinking water for China’s capital, Beijing, which has a population of 21.75 million. Recently, the capacity of the Miyun reservoir to supply clean drinking water is threatened by increasing eutrophication (or algae bloom), mainly due to the discharge of wastewater and excessive fertilization application in the upstream watershed. Therefore, there is an urgent need to design effective best management practices (BMPs) to reduce upstream nutrient load and improve water quality in the Miyun reservoir. In this study, we built a watershed model (i.e. the Soil and Water Assessment Tool) in the Miyun Reservoir Watershed (MRW), and calibrated and validated it using long term sediment, nitrogen (N) and phosphorus (P) data. Further, we developed a Markov Chain based multi-objective optimization program to explore optimal BMPs with tradeoffs between economic costs and water quality responses. With the watershed model and the multi-objective optimization algorithms, we explored potential effectiveness of BMPs under two scenarios that are currently being considered: scenario 1 assumes funding of BMP implementation is from national grants and targets high water quality standard, while scenario 2 assumes funding is from farmers and targets water quality that barely meet the drinking water standard. We found substantial discrepancy between these two scenarios with respect to type and spatial configuration of BMPs and associated economic costs, highlighting the need of reconciling concerns from different stakeholders in order to arrive at a BMP plan that all parties will agree upon. In addition, we found that cross-subwatershed coordination and targeting flood season instead of year-round water quality standards could pronouncedly reduce economic cost of BMP implementation while not substantially degrade water quality. The watershed scale optimization method developed here hold the promise serve as an effective tool to explore tradeoffs between economic costs, water quality improvements, and decisions makers and stakeholders’ concerns in BMPs design, thereby informing sustainable watershed scale water resources management.

Qiu, Jiali↗