Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “light field imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Direct Volume Rendering with Shading via Three-Dimensional Textures

A new and easy-to-implement method for direct volume rendering that uses 3D texture maps for acceleration, and incorporates directional lighting, is described. The implementation, called Voltx, produces high-quality images at nearly interactive speeds on workstations with hardware support for three-dimensional texture maps. Previously reported methods did not incorporate a light model, and did not address issues of multiple texture maps for large volumes. Our research shows that these extensions impact performance by about a factor of ten. Voltx supports orthographic, perspective, and stereo views. This paper describes the theory and implementation of this technique, and compares it to the shear-warp factorization approach. A rectilinear data set is converted into a three-dimensional texture map containing color and opacity information. Quantized normal vectors and a lookup table provide efficiency. A new tesselation of the sphere is described, which serves as the basis for normal-vector quantization. A new gradient-based shading criterion is described, in which the gradient magnitude is interpreted in the context of the field-data value and the material classification parameters, and not in isolation. In the rendering phase, the texture map is applied to a stack of parallel planes, which effectively cut the texture into many slabs. The slabs are composited to form an image.

VanGelder, Allen↗

Visual Systems for Remotely Controlled Vehicles

The Variable Acuity Remote Viewing System is discussed. It was conceived as a technique for resolving the field of view/resolution/ bandwidth tradeoffs that exist in remote viewing systems. This system is based on the fact that integration of the human eye acuity function shows only about 130,000 pixels are required to fully support the human vision. This quantity is well within the capabilities of conventional video systems. The technique utilizes a non-linear optical system in both the sensing and display equipment. The non-linearity is achieved by a special lens which translates a uniform pixel array on its image plane into the object field as a variable angular array. This lens will record the same angular detail the eye would see when viewing the same scene and compress this detail into a uniform matrix of equal sized picture elements on its image plane. This image can be scanned with a broadcast quality tv having a 525 line raster scan. Conventional transmission equipment can then also be used to send the image information to a remote location. When received, the image is projected by a light valve projector onto a hemispherical screen by an identical non-linear lens.

Rezek, T.↗

Search for 1-10 Hz Modulations in Coronal Emission with SECIS During the August 11, 1999 Eclipse

Results of the search of the periodic changes of the 530.3 nm line intensity emitted by selected structures of the solar corona in the frequency range 1-10 Hz are presented. A set of 12728 images of the section of the solar corona extending from near the north pole to the south-west were taken simultaneously in the 530.3 nm ('green') line and white-light with the Solar Eclipse Coronal Imaging System (SECIS) during the 143-seconds-long totality of the 1999 August 11 solar eclipse observed in Shabla, Bulgaria. The time resolution of the collected data is better than 0.05-s and the pixel size is approximately 4 arcsecs. Using classical Fourier spectral analysis tools, we investigated temporal changes of the local 530.3 nm coronal line brightness in the frequency range 1-10 Hz of thousands of points within the field of view. The various photometric and instrumental effects have been extensively considered. We did not find any indisputable, statistically significant evidence of periodicities in any of the investigated points (at significance level alpha = 0.05 or better).

Rudawy, P.↗

A Magnetron Sputter Deposition System for the Development of Multilayer X-Ray Optics

The proposal objective is to establish the capability to deposit multilayer structures for x-ray, neutron, and EUV optic applications through the development of a magnetron sputtering deposition system. A specific goal of this endeavor is to combine multilayer deposition technology with the replication process in order to enhance the MSFC's position as a world leader in the design of innovative X-ray instrumentation through the development of full shell replicated multilayer optics. The development of multilayer structures is absolutely necessary in order to advance the field of X-ray astronomy by pushing the limit for observing the universe to ever increasing photon energies (i. e. up to 200 keV or higher); well beyond Chandra (approx. 10 keV) and NuStar's (approx. 75 keV) capability. The addition of multilayer technology would significantly enhance the X-ray optics capability at MSFC and allow NASA to maintain its world leadership position in the development, fabrication and design of innovative X-ray instrumentation which would be the first of its kind by combining multilayer technology with the mirror replication process. This marriage of these technologies would allow astronomers to see the universe in a new light by pushing to higher energies that are out of reach with today's instruments.To this aim, a magnetron vacum sputter deposition system for the deposition of novel multilayer thin film X-ray optics is proposed. A significant secondary use of the vacuum deposition system includes the capability to fabricate multilayers for applications in the field of EUV optics for solar physics, neutron optics, and X-ray optics for a broad range of applications including medical imaging.

Broadway, David↗

Comparing Machine Learning and Physics-Based Nanoparticle Geometry Determinations Using Far-Field Spectral Properties

Anisotropic metal nanostructures exhibit polarization-dependent light scattering, a property which has been widely studied and exploited to determine orientations of subwavelength structures using far-field microscopy. Here we explore the use of variational autoencoders (VAEs) to determine the geometries of gold nanorods (NRs) such as in-plane orientation and aspect ratio under linearly polarized dark-field illumination in an optical microscope. We enforce a shared latent space to connect two VAEs trained separately with polarized dark-field scattering spectra and electron microscopy images and achieve image prediction (shape, orientation, and size) of Au NRs using only polarized dark-field scattering spectra. We determine the geometrical parameters of orientational angle and aspect ratio quantitatively via both our dual-VAE and physics-based analysis on the input scattering spectra. We show that orientational angle prediction by dual-VAE performs well with only a small (~300 particle) training set, yielding a mean absolute error (MAE) of 14.4° and a concordance correlation coefficient (CCC) of 0.95. This performance is only marginally worse than the physics-based cos(2?) fitting approach between the scattering intensity and the polarizing angle, which achieves MAE of 8.78° and CCC of 0.99. Aspect ratio determination is also comparable for the dual-VAE and physics-based fitting comparison (MAE of 0.21 vs. 0.23 and CCC of 0.53 vs. 0.68). Here, this dual encoder-decoder architecture effectively exploits the structure-property relationships of plasmonic nanostructures to construct a cross-modal machine learning (ML) approach, providing a pathway to employ ML approaches to address other structure-property relationships in materials science.

Dark-field scattering↗

Mid-infrared Pulsed Upconversion Imaging in a Rotating Detonation Combustor

To meet the challenges associated with performing mid-InfraRed (IR) imaging in Rotating Detonation Combustors (RDCs), a novel pulsed mid-IR UpConversion Imaging (UCI) diagnostic has been implemented. UCI is an alternative to direct mid-IR detection that uses nonlinear optical frequency mixing to shift mid-IR wavelengths carrying a target image to shorter wavelengths that can be imaged with high-performance silicon-based CCD/CMOS cameras. This approach offers several favorable properties including high spectral selectivity, high temporal resolution, and superior low-light detectivity. A hydrogen-air research RDC was operated with carbon dioxide addition to allow pulsed UCI imaging of mid-IR luminosity within the combustion channel from spontaneous thermal emissions. The resulting measurements demonstrate high spatiotemporal resolution capable of imaging small structures near the supersonically propagating detonation wave front. The results show how this technique can be used to observe sharp gradients and millimeter-scale structures in the high-temperature, high-pressure zones RDC flow fields.

White, Logan W.↗

The Space Telescope

The Space Telescope, still under construction, is discussed in light of the constraints imposed on ground-based telescopes. The history of the Space Telescope is traced from its conceptual origin to its actual construction, and design considerations used to determine the Space Telescope construction are described. The optical system of the telescope will have an aperture of 2.4 m, a focal ratio of 24, and a front of primary to focus of 1.5 m. The fine guidance system will use astigmatic images at the edge of the field of view to provide the guidance signal for maintaining stability to 0.007 arcseconds. The guidestars are required for 85% of random fields located at the galactic poles, and the system sensitivity must meet performance specifications for stars brighter than 13.5 magnitude. The scientific instruments - the wide field camera, the faint object camera, the faint object spectrograph, the high resolution spectrograph, the high speed photometer, and the fine guidance sensors - are discussed in detail. Finally, the operations system, including schedule contraints and the Science Institute, is presented.

Odell, C. R.↗

A Magnetron Sputter Deposition System for the Development of X-Ray Multilayer Optics

The project objective is to establish the capability to deposit multilayer structures for x-ray, neutron, and extreme ultraviolet (EUV) optic applications through the development of a magnetron sputtering deposition system. A specific goal of this endeavor is to combine multilayer deposition technology with the replication process in order to enhance NASA Marshall Space Flight Center's (MSFC's) position as a world leader in the design of innovative x-ray instrumentation through the development of full shell replicated multilayer optics. The development of multilayer structures are absolutely necessary in order to advance the field of x-ray astronomy by pushing the limit for observing the universe to ever-increasing photon energies (i.e., up to 200 keV or higher), well beyond Chandra's (approx.10 keV) and NuStar's (approx.75 keV) capability. The addition of multilayer technology would significantly enhance the x-ray optics capability at MSFC and allow NASA to maintain its world leadership position in the development, fabrication, and design of innovative x-ray instrumentation, which would be the first of its kind by combining multilayer technology with the mirror replication process. This marriage of these technologies would allow astronomers to see the universe in a new light by pushing to higher energies that are out of reach with today's instruments. To this aim, a magnetron vacuum sputter deposition system for the deposition of novel multilayer thin film x-ray optics is proposed. A significant secondary use of the vacuum deposition system includes the capability to fabricate multilayers for applications in the field of EUV optics for solar physics, neutron optics, and x-ray optics for a broad range of applications including medical imaging.

Broadway, David↗

Topographic Quintet: Comparing Five Methods for Measuring Ultra-High Resolution Topography

We compare different methods for collecting ultra-high resolution topography data within an analog planetary, human landing site scale area. Our aim is to investigate the cost and benefits of different 3D terrain mapping techniques, their associated data collection methods, and how their different specifications (e.g., range, spatial resolution, scanning-time, mobility, operating constraints, GPS-Denied operation, etc.) might be applied to landing-site characterization and mission operations. We compare 3D terrain data collected during a field campaign in November 2021 from an outcrop at Kilbourne Hole in southern New Mexico using different Light Detection and Ranging (LiDAR) sensors on the ground and stereo-derived 3D data from framing cameras mounted on small uncrewed aerial systems (sUAS).Our foci for this experiment are ground-based, surveying, and autonomous vehicle-type 3D scanning sensors that might be used for planetary surface exploration from landed assets (e.g., lander, rover, astronaut-mounted sensors, decent imaging, hoppers, or drones).[e.g. 1]This test is not meant to benchmark these scanners against one another, nor provide a recommendation for a specific make or model. Rather, our goal is to quantify time, effort, resolution, and operational trade-offs that are important for selecting a topographic instrument/methodology for a given scope of terrain characterization. Our results indicate that each technique is capable of exceptional quality terrain characterization for planetary exploration and scientific inquiry, but we hypothesize the appropriate technique is highly dependent on the scope of operational specifications and science requirements.

P Whelley↗

Experimental Investigation of Pool Boiling Heat Transfer Enhancement in Microgravity in the Presence of Electric Fields

In boiling high heat fluxes are possible driven by relatively small temperature differences, which make its use increasingly attractive in aerospace applications. The objective of the research is to develop ways to overcome specific problems associated with boiling in the low gravity environment by substituting the buoyancy force with the electric force to enhance bubble removal from the heated surface. Previous studies indicate that in terrestrial applications nucleate boiling heat transfer can be increased by a factor of 50, as compared to values obtained for the same system without electric fields. The goal of our research is to experimentally explore the mechanisms responsible for EHD heat transfer enhancement in boiling in low gravity conditions, by visualizing the temperature distributions in the vicinity of the heated surface and around the bubble during boiling using real-time holographic interferometry (HI) combined with high-speed cinematography. In the first phase of the project the influence of the electric field on a single bubble is investigated. Pool boiling is simulated by injecting a single bubble through a nozzle into the subcooled liquid or into the thermal boundary layer developed along the flat heater surface. Since the exact location of bubble formation is known, the optical equipment can be aligned and focused accurately, which is an essential requirement for precision measurements of bubble shape, size and deformation, as well as the visualization of temperature fields by HI. The size of the bubble and the frequency of bubble departure can be controlled by suitable selection of nozzle diameter and mass flow rate of vapor. In this approach effects due to the presence of the electric field can be separated from effects caused by the temperature gradients in the thermal boundary layer. The influence of the thermal boundary layer can be investigated after activating the heater at a later stage of the research. For the visualization experiments a test cell was developed. All four vertical walls of the test cell are transparent, and they allow transillumination with laser light for visualization experiments by HI. The bottom electrode is a copper cylinder, which is electrically grounded. The copper block is heated with a resistive heater and it is equipped with 6 thermocouples that provide reference temperatures for the measurements with HI. The top electrode is a mesh electrode. Bubbles are injected with a syringe into the test cell through the bottom electrode. The working fluids presently used in the interferometric visualization experiments, water and PF 5052, satisfy requirements regarding thermophysical, optical and electrical properties. A 30kV power supply equipped with a voltmeter allows to apply the electric field to the electrodes during the experiments. The magnitude of the applied voltage can be adjusted either manually or through the LabVIEW data acquisition and control system connected to a PC. Temperatures of the heated block are recorded using type-T thermocouples, whose output is read by a data acquisition system. Images of the bubbles are recorded with 35mm photographic and 16mm high-speed cameras, scanned and analyzed using various software packages. Visualized temperature fields HI allows the visualization of temperature fields in the vicinity of bubbles during boiling in the form of fringes. Typical visualized temperature distributions around the air bubbles injected into the thermal boundary layer in PF5052 are shown. The temperature of the heated surface is 35 C. The temperature difference for a pair of fringes is approximately 0.05 C. The heat flux applied to the bottom surface is moderate, and the fringe patterns are regular. In the image a bubble penetrating the thermal boundary layer is visible. Because of the axial symmetry of the problem, simplified reconstruction techniques can be applied to recover the temperature field. The thermal plume developing above the heated surface for more intensive heating is shown. The temperature distribution in the liquid is clearly 3D, and tomographic techniques have to be applied to recover the temperature distribution in such a physical situation. A sequence of interferometric images showing the temperature distribution around the rising bubble, recorded with a high-speed camera is shown. Again, the temperature distribution is 3D, and a more complex approach to the evaluation, the tomographic reconstruction has to be taken. Measurement of the temperature distribution from the fringe pattern temperature distributions that yield important information regarding heat transfer are determined. Two algorithms that allow the quantitative evaluation of interferometric fringe patterns and the reconstruction of temperature fields during boiling have been developed at the Heat Transfer Laboratory of the Johns Hopkins University. In the first algorithm the bubble is assumed to be axially symmetrical, which significantly reduces the computational effort for quantifying the temperature distribution around the bubble. For this purpose the thermal boundary layer around the bubble is divided into equidistant concentric shells, and the refractive index is assumed to be constant in each of the shells. Since large temperature gradients are expected in the vicinity of the bubble during boiling, the deflection of the light beam cannot be neglected in boiling experiments. Since the exit angle of the light beam is known, this allows to account for the deflections and phase shifts outside the boundary layer (in the bulk fluid and in the windows of the test cell). Three dimensional temperature distributions in the vicinity of the bubble are reconstructed using tomographic techniques. In tomography, the measurement volume is sliced into 2D planes. In the present study these planes are parallel to the heated surface. The objective is to determine the values of the field parameter of interest in form of the field function in these 2D planes. The field parameter is the change of the refractive index of the liquid in the measurement volume caused by temperature changes. By superimposing data for many 2D planes recorded at the same time instant, the 3D temperature distribution in the measurement volume is recovered.

Herman, Cila↗

Concentration and Velocity Gradients in Fluidized Beds

In this work we focus on the height dependence of particle concentration, average velocity components, fluctuations in these velocities and, with the flow turned off, the sedimentation velocity. The latter quantities are measured using Particle Imaging Velocimetry (PIV). The PIV technique uses a 1-megapixel camera to capture two time-displaced images of particles in the bed. The depth of field of the imaging system is approximately 0.5 cm. The camera images a region with characteristic length of 2.6 cm for the small particles and 4.7 cm. for the large particles. The local direction of particle flow is determined by calculating the correlation function for sub-regions of 32 x 32 pixels. The velocity vector map is created from this correlation function using the time between images (we use 15 to 30 ms). The software is sensitive variations of 1/64th of a pixel. We produce velocity maps at various heights, each consisting of 3844 velocities. We break this map into three vertical zones for increased height information. The concentration profile is measured using an expanded (1 cm diameter) linearly polarized HeNe Laser incident on the fluidized bed. A COHU camera (gamma=1, AGC off) with a lens and a polarizer images the transmitted linearly polarized light to minimize the effects of multiply scattered light. The intensity profile (640 X 480 pixels) is well described by a Gaussian fit and the height of the Gaussian is used to characterize the concentration. This value is compared to the heights found for known concentrations. The sedimentation velocity is estimated using by imaging a region near the bottom of the bed and using PIV to measure the velocity as a function of time. With a nearly uniform concentration profile, the time can be converted to height information. The stable fluidized beds are made from large pseudo-monodisperse particles (silica spheres with radii (250-300) microns and (425-500) microns) dispersed in a glycerin/water mix. The Peclet number is sufficiently large that Brownian motion of the particles can be ignored and the Reynolds number sufficiently small that particle inertia is negligible. A packed particle bed is used to randomize and disperse the flowing fluid introduced by a peristaltic pump. The bed itself is a rectangular glass cell 8 cm wide (x), 0.8 cm deep and a height of 30.5 cm (z). The depth of field of the camera is approximately 0.5 cm so depth information is averaged. Over flow fluid is returned to the reservoir making a closed loop system. In these experiments the particles form a sediment approximately 5.7 cm high with the pump off and expand to 22 cm with the pump on. For the smaller particles the pump velocity is .5 millimeters per second and 1.1 millimeters per second for the large particles. At this concentration the bed has a very well defined top where particle concentration rapidly drops to zero.

McClymer, James P.↗

Quantum light: creation, integration, and applications

In today’s rapidly evolving quantum landscape, the generation and manipulation of quantum light not only represent fundamental challenges but also herald unprecedented opportunities in communication, computing, sensing, and imaging. This special issue brings together a collection of contributions that span the entire journey, from the creation of quantum light using novel materials and emitters to its seamless integration into photonic architectures and eventual deployment in advanced quantum applications. This special issue, “Quantum Light: Creation, Integration, and Applications,” features a collection of three review articles, five perspectives, and 23 original research papers, highlighting both the timeliness of the topic and the remarkable breadth and richness of ongoing advancements in the field.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Effects of levitated dust on astronomical observations from the lunar surface

It is believed that a substantial population of levitated dust is present in the terminator region of the moon. Stray light scattered by this dust layer may contaminate astronomical observations made from the lunar surface using infrared, visible, and ultraviolet light. The evidence for dust levitation stems from: Surveyor vidicon images of horizon glow; anomalous brightness in photographs of the solar corona taken by Apollo astronauts while the spacecraft was just inside the moon's shadow; and observations by Apollo astronauts of streamers just prior to lunar orbital sunrise or just after lunar orbital sunset. It has been proposed that the differential charging of the lunar surface in the terminator region due to photoemission and the consequent strong local electric fields comprise the mechanism responsible for this levitation. Although quantitative data on the levitated lunar dust distribution are meager, it is possible to estimate column densities and sizes. In this paper we summarize the estimates of particulate sizes and number densities of previous authors, and construct a nominal terminator dust distribution, as a function of particulate radius and altitude above the lunar surface. Using the model we estimate the brightness of scattered sunshine for three wavelength bands. For the results in the visible wavelengths, we compare the estimated brightness with the known brightness of selected astronomical objects and discuss the implications for lunar-based astronomy.

Murphy, D. L.↗

Application of Digital Particle Imaging Velocimetry to Turbomachinery

Digital Particle Imaging Velocimetry (DPIV) is a powerful measurement technique, which can be used as an alternative or complementary approach to Laser Doppler Velocimetry (LDV) in a wide range of research applications. The instantaneous planar velocity measurements obtained with PIV make it an attractive technique for use in the study of the complex flow fields encountered in turbomachinery. Many of the same issues encountered in the application of LDV to rotating machinery apply in the application of PIV. Techniques for optical access, light sheet delivery, CCD camera technology and particulate seeding are discussed. Results from the successful application of the PIV technique to both the blade passage region of a transonic axial compressor and the diffuser region of a high speed centrifugal compressor are presented. Both instantaneous and time-averaged flow fields were obtained. The 95% confidence intervals for the time-averaged velocity estimates were also determined. Results from the use of PIV to study surge in a centrifugal compressor are discussed. In addition, combined correlation/particle tracking results yielding super-resolution velocity measurements are presented.

Wernet, Mark P.↗

Hot Views on Cold Crystals: The Application of Thermal Imaging in Cryocrystallography

We have used thermal imaging techniques to visualize the cryocooling processes of macromolecular crystals. Cryocooling is a common technique used for structural data collection to reduce radiation damage in intense X-ray beams and decrease the thermal motion of the atoms. From the thermal images it was clear that during cryocooling a cold wave progresses through a crystal starting at the face closest to the origin of the cold stream and ending at the point furthest away. As an extension to this work, we used thermal imaging to study small crystals, held in a cryo-loop, in the presence of vitrified mother liquor. The different infrared transmission and reflectance properties of the crystal in comparison to the mother liquor surrounding it are thought to be the parameter that produces the contrast that makes the crystal visible. An application of this technology may be the determination of the exact location of small crystals in a cryo-loop for automated structural genomics studies. Data from initial tests in support of application development was recorded for lysozyme crystals and for bFGF/dna complex crystals, which were cryocooled and imaged in large loops, both with visible light and with infrared radiation. The crystals were clearly distinguished from the vitrified solution in the infrared spectrum, while in the case of the bFGF/dna complex the illumination had to be carefully manipulated to make the crystal visible in the visible spectrum. These results suggest that the thermal imaging may be more sensitive than visual imaging for automated location of small crystals. However, further work on small crystals robotically mounted at SSRL did not clearly visualize those crystals. The depth of field of the camera proved to be limiting and a different cooling geometry was used, compared to the previous, successful experiments. Analysis to exploit multiple images to improve depth of field and experimental work to understand cooling geometry effects is ongoing. These results will be presented along with advantages and disadvantages of the technique and a discussion of how it might be applied.

Snell, Eddie↗

Hot Views on Cold Crystals: The Application of Thermal Imaging in Cryocrystallography

In the past we have used thermal imaging techniques to visualize the cryocooling processes of macromolecular crystals. From these images it was clear that a cold wave progresses through a crystal starting at the face closest to the origin of the cold stream and ending at the point furthest away. During these studies we used large volume crystals, which were clearly distinguished from the loop holding them. These large crystals, originally grown for neutron diffraction studies, were chosen deliberately to enhance the imaging. As an extension to this work, we used thermal imaging to study small crystals, held in a cryo- loop, in the presence of vitrified mother liquor. The different infrared transmission and reflectance properties of the crystal in comparison to the mother liquor surrounding it are thought to be the parameter that produces the contrast that makes the crystal visible. An application of this technology may be the determination of the exact location of small crystals in a cryo-loop. Data from initial tests in support of application development was recorded for lysozyme crystals and for bFGF/dna complex crystals, which were cryo-cooled and imaged in large loops, both with visible light and with infrared radiation. The crystals were clearly distinguished from the vitrified solution in the infrared spectrum, while in the case of the bFGF/dna complex the illumination had to be carefully manipulated to make the crystal visible in the visible spectrum. These results suggest that the thermal imaging may be more sensitive than visual imaging for automated location of small crystals. However, further work on small crystals robotically mounted at SSRL did not clearly visualize those crystals. The depth of field of the camera proved to be limiting and a different cooling geometry was used, compared to the previous, successful experiments. Analysis to exploit multiple images to improve depth of field and experimental work to understand cooling geometry effects is ongoing. These results will be presented along with advantages and disadvantages of the technique and a discussion of how it might be applied .

Snell, Eddie H.↗

Hot Views on Cold Crystals: The Application of Thermal Imaging in Cryo-crystallography

In the past we have used thermal imaging techniques to visualize the cryocooling processes of macromolecular crystals. From these images it was clear that a cold wave progresses through a crystal starting at the face closest to the origin of the cold stream and ending at the point furthest away. During these studies we used large volume crystals, which were clearly distinguished from the loop holding them. These large crystals, originally grown for neutron diffraction studies, were chosen deliberately to enhance the imaging. As an extension to this work, we present used thermal imaging to study small crystals, held in a cryo-loop, in the presence of vitrified mother liquor. The different infrared transmission and reflectance properties of the crystal in comparison to the mother liquor surrounding it are thought to be the parameter that produces the contrast that makes the crystal visible. An application of this technology may be the determination of the exact location of small crystals in a cryo-loop. Data from initial tests in support of application development was recorded for lysozyme crystals and for bFGF/dna complex crystals, which were cryo-cooled and imaged in large loops, both with visible light and with infrared radiation. The crystals were clearly distinguished from the vitrified solution in the infrared spectrum, while in the case of the bFGF/dna complex the illumination had to be carefully manipulated to make the crystal visible in the visible spectrum. These results suggest that the thermal imaging may be more sensitive than visual imaging for automated location of small crystals. However, further work on small crystals robotically mounted at SSRL did not clearly visualize those crystals. The depth of field of the camera proved to be limiting and a different cooling geometry was used, compared to the previous, successful experiments. Analysis to exploit multiple images to improve depth of field and experimental work to understand cooling geometry effects is ongoing. These results will be presented along with advantages and disadvantages of the technique and a discussion of how it might be applied.

Snell, E. H.↗

Determination of the Limiting Magnitude

The limiting magnitude of an optical camera system is an important property to understand since it is used to find the completeness limit of observations. Limiting magnitude depends on the hardware and software of the system, current weather conditions, and the angular speed of the objects observed. If an object exhibits a substantial angular rate during the exposure, its light spreads out over more pixels than the stationary stars. This spreading causes the limiting magnitude to be brighter when compared to the stellar limiting magnitude. The effect, which begins to become important when the object moves a full width at half max during a single exposure or video frame. For targets with high angular speeds or camera systems with narrow field of view or long exposures, this correction can be significant, up to several magnitudes. The stars in an image are often used to measure the limiting magnitude since they are stationary, have known brightness, and are present in large numbers, making the determination of the limiting magnitude fairly simple. In order to transform stellar limiting magnitude to object limiting magnitude, a correction must be applied accounting for the angular velocity. This technique is adopted in meteor and other fast-moving object observations, as the lack of a statistically significant sample of targets makes it virtually impossible to determine the limiting magnitude before the weather conditions change. While the weather is the dominant factor in observing satellites, the limiting magnitude for meteors also changes throughout the night due to the motion of a meteor shower or sporadic source radiant across the sky. This paper presents methods for determining the limiting stellar magnitude and the conversion to the target limiting magnitude.

Kingery, Aaron↗