Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “intervals”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Tumor Bed Dynamics After Surgical Resection of Brain Metastases: Implications for Postoperative Radiosurgery

Purpose: To analyze 2 factors that influence timing of radiosurgery after surgical resection of brain metastases: target volume dynamics and intracranial tumor progression in the interval between surgery and cavity stereotactic radiosurgery (SRS). Methods and Materials: Three diagnostic magnetic resonance imaging (MRI) scans were retrospectively analyzed for 41 patients with a total of 43 resected brain metastases: preoperative MRI scan (MRI-1), MRI scan within 24 hours after surgery (MRI-2), and MRI scan for radiosurgery planning, which is generally performed {<=}1 week before SRS (MRI-3). Tumors were contoured on MRI-1 scans, and resection cavities were contoured on MRI-2 and MRI-3 scans. Results: The mean tumor volume before surgery was 14.23 cm{sup 3}, and the mean cavity volume was 8.53 cm{sup 3} immediately after surgery and 8.77 cm{sup 3} before SRS. In the interval between surgery and SRS, 20 cavities (46.5%) were stable in size, defined as a change of {<=}2 cm{sup 3}; 10 cavities (23.3%) collapsed by >2 cm{sup 3}; and 13 cavities (30.2%) increased by >2 cm{sup 3}. The unexpected increase in cavity size was a result of local progression (2 cavities), accumulation of cyst-like fluid or blood (9 cavities), and nonspecific postsurgical changes (2 cavities). Finally, in the interval between surgery and SRS, 5 cavities showed definite local tumor progression, 4 patients had progression elsewhere in the brain, 1 patient had both local progression and progression elsewhere, and 33 patients had stable intracranial disease. Conclusions: In the interval between surgical resection and delivery of SRS, surgical cavities are dynamic in size; however, most cavities do not collapse, and nearly one-third are larger at the time of SRS. These observations support obtaining imaging for radiosurgery planning as close to SRS delivery as possible and suggest that delaying SRS after surgery does not offer the benefit of cavity collapse in most patients. A prospective, multi-institutional trial will provide more guidance to the optimal timing of cavity SRS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intrafraction Prostate Translations and Rotations During Hypofractionated Robotic Radiation Surgery: Dosimetric Impact of Correction Strategies and Margins

Purpose: To investigate the dosimetric impact of intrafraction prostate motion and the effect of robot correction strategies for hypofractionated CyberKnife treatments with a simultaneously integrated boost. Methods and Materials: A total of 548 real-time prostate motion tracks from 17 patients were available for dosimetric simulations of CyberKnife treatments, in which various correction strategies were included. Fixed time intervals between imaging/correction (15, 60, 180, and 360 seconds) were simulated, as well as adaptive timing (ie, the time interval reduced from 60 to 15 seconds in case prostate motion exceeded 3 mm or 2° in consecutive images). The simulated extent of robot corrections was also varied: no corrections, translational corrections only, and translational corrections combined with rotational corrections up to 5°, 10°, and perfect rotational correction. The correction strategies were evaluated for treatment plans with a 0-mm or 3-mm margin around the clinical target volume (CTV). We recorded CTV coverage (V{sub 100%}) and dose-volume parameters of the peripheral zone (boost), rectum, bladder, and urethra. Results: Planned dose parameters were increasingly preserved with larger extents of robot corrections. A time interval between corrections of 60 to 180 seconds provided optimal preservation of CTV coverage. To achieve 98% CTV coverage in 98% of the treatments, translational and rotational corrections up to 10° were required for the 0-mm margin plans, whereas translational and rotational corrections up to 5° were required for the 3-mm margin plans. Rectum and bladder were spared considerably better in the 0-mm margin plans. Adaptive timing did not improve delivered dose. Conclusions: Intrafraction prostate motion substantially affected the delivered dose but was compensated for effectively by robot corrections using a time interval of 60 to 180 seconds. A 0-mm margin required larger extents of additional rotational corrections than a 3-mm margin but resulted in lower doses to rectum and bladder.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Association of Locoregional Control With High Body Mass Index in Women Undergoing Breast Conservation Therapy for Early-Stage Breast Cancer

Purpose: Obesity, as measured by the body mass index (BMI), is a risk factor for distant recurrence and decreased survival in breast cancer. We sought to determine whether the BMI correlated with local recurrence and reduced survival in a cohort of predominantly obese women treated with breast conservation therapy. Methods and Materials: From 1998 to 2010, 154 women with early-stage invasive breast cancer and 39 patients with ductal carcinoma in situ underwent prone whole breast irradiation. Cox proportional hazards regression, Kaplan-Meier methods with the log-rank test, and multivariate analysis were used to explore the association of the outcomes with the BMI. Results: The median patient age was 60 years, and the median follow-up duration was 73 months. The median BMI was 33.2 kg/m{sup 2}; 91% of the patients were overweight (BMI ≥25 kg/m{sup 2}) and 69% of the patients were clinically obese (BMI ≥30 kg/m{sup 2}). The BMI was significantly associated with the locoregional recurrence-free interval for patients with invasive cancer and ductal carcinoma in situ (hazard ratio [HR], 1.09; P=.047). Also, a trend was seen for increased locoregional recurrence with a higher BMI (P=.09) for patients with invasive disease, which was significant when examining the outcomes with a BMI stratified by the median value of 33.2 kg/m{sup 2} (P=.008). A greater BMI was also significantly associated with decreased distant recurrence-free interval (HR, 1.09; P=.011) and overall survival (HR, 1.09; P=.004); this association remained on multivariate analysis (distant recurrence-free interval, P=.034; overall survival, P=.0007). Conclusions: These data suggest that the BMI might affect the rate of locoregional recurrence in breast cancer patients. A higher BMI predicted a worse distant recurrence-free interval and overall survival. The present investigation adds to the increasing evidence that BMI is an important prognostic factor in early-stage breast cancer treated with breast conservation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Determination of monitor unit check tolerances based on a comparison with measurement and treatment planning system data

ABSTRACT: This work describes the experimental validation of treatment planning system monitor unit (MU) calculations against measurement for a range of scenarios. This, together with a comparison of treatment planning system MUs and an independent MU check method, allows the derivation of confidence intervals for the check process. Data were collected for open and 60° motorized wedge fields using an Elekta Synergy linac at 6 and 8 MV using homogeneous and heterogeneous phantoms. Masterplan (Version 4.0) pencil-beam and collapsed cone algorithms were used for the primary MU calculations with full inhomogeneity correction. Results show that both algorithms agree with measurement to acceptable tolerance levels in the majority of the cases studied. The confidence interval for the pencil-beam algorithm MU against an independent check was determined as + 1.6% to −3.4%. This is modified to + 2.3% to −2.5% when data collected with low-density heterogeneities are removed as this algorithm is not used clinically for these cases. The corresponding interval for the collapsed cone algorithm was + 1.2% to −4.3%, indicating that an offset tolerance for the independent check is appropriate. Analysis of clinical conformal treatment plan data generated using the pencil-beam algorithm (1393 beams) returned 93% of beams within the independent check tolerance. Similarly, using the collapsed cone algorithm as the primary MU calculation, 77% (of 1434 beams) were within the confidence interval.

61 RADIATION PROTECTION AND DOSIMETRY↗

The effect of birthrate granularity on the release-to-birth ratio for the AGR-1 in-core experiment

The AGR-1 Advanced Gas Reactor (AGR) tristructural-isotropic-particle fuel experiment underwent 13 irradiation intervals from December 2006 until November 2009 within the Idaho National Laboratory Advanced Test Reactor in support of the Next Generation Nuclear Power Plant program. During this multi-year experiment, release-to-birth rate ratios were computed at the end of each operating interval to provide information about fuel performance. Fission products released during irradiation were tracked daily by the Fission Product Monitoring System using 8-h measurements. Birth rate calculated by MCNP with ORIGEN for as-run conditions were computed at the end of each irradiation interval. Each time step in MCNP provided neutron flux, reaction rates and AGR-1 compact composition, which were used to determine birth rate using ORIGEN. The initial birth-rate data, consisting of four values for each irradiation interval at the beginning, end, and two intermediate times, were interpolated to obtain values for each 8-h activity. The problem with this method is that any daily changes in heat rates or perturbations, such as shim control movement or core/lobe power fluctuations, would not be reflected in the interpolated data and a true picture of the system would not be presented. At the conclusion of the AGR-1 experiment, great efforts were put forth to compute daily birthrates, which were reprocessed with the 8-h release activity. The results of this study are presented in this paper.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Λ c + production in Pb–Pb collisions at s NN = 5.02 TeV

A measurement of the production of prompt $\Lambda^+_c$ baryons in Pb–Pb collisions at $\sqrt{s_{NN}} = 5.02$ TeV with the ALICE detector at the LHC is reported. The $\Lambda^+_c$ and $\Lambda^-_c$ were reconstructed at midrapidity ($\mid{y}\mid < 0.5$) via the hadronic decay channel $\Lambda^+_c$ $\rightarrow {pK^0_s}$ (and charge conjugate) in the transverse momentum and centrality intervals GeV/c and 0–80%. The ratio, which is sensitive to the charm quark hadronisation mechanisms in the medium, is measured and found to be larger than the ratio measured in minimum-bias pp collisions at TeV and in p–Pb collisions at TeV. In particular, the values in p–Pb and Pb–Pb collisions differ by about two standard deviations of the combined statistical and systematic uncertainties in the common interval covered by the measurements in the two collision systems. The ratio is also compared with model calculations including different implementations of charm quark hadronisation. The measured ratio is reproduced by models implementing a pure coalescence scenario, while adding a fragmentation contribution leads to an underestimation. The nuclear modification factor, , is also presented. The measured values of the of , and non-strange D mesons are compatible within the combined statistical and systematic uncertainties. They show, however, a hint of a hierarchy , conceivable with a contribution from coalescence mechanisms to charm hadron formation in the medium.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Increased risk of QT prolongation associated with atherosclerotic diseases in arseniasis-endemic area in southwestern coast of Taiwan

Chronic arsenic exposure has been documented to be associated with various cardiovascular diseases. We aimed to investigate 1) the increased risk of QT prolongation in chronic arsenic exposure, and 2) the relationships of cardiac repolarization (QT interval duration) with ischemic heart disease and carotid atherosclerosis. We studied 280 men and 355 women living in the endemic area of arseniasis in southwestern Taiwan. QT intervals in electrocardiogram and carotid intima-media thickness (IMT) by ultrasonography were measured. Ischemic heart disease was diagnosed by history or abnormal electrocardiogram. Significant associations of the corrected QT interval (QTc) duration with ischemic heart disease and carotid intima-medium thickness and plaque were observed after adjustment for various risk factors in the multiple linear regression analysis (all p values < 0.05). Three indices of chronic arsenic exposure were all significantly associated with the risk of QTc prolongation showing dose-response relationships (p < 0.001). Chronic arsenic exposure was dose-dependently associated with the risk of QTc prolongation. Ischemic heart disease and carotid atherosclerosis were significantly associated with QTc intervals in chronic arsenic exposure. QTc prolongation might be suggested as an early biomarker for ischemic heart disease or carotid atherosclerosis in population with previous exposure to arsenic.

60 APPLIED LIFE SCIENCES↗

Duration of O 2 Exposure Determines Dominance of Fe II vs CH 4 Production in Tropical Forest Soils

Temporal fluctuations in redox conditions influence the availability of Fe III and greenhouse gas emissions in humid upland soils. However, the impact of fluctuation duration on biogeochemical processes remains unclear. We hypothesized that rates of Fe III reduction and CH 4 production are sensitive to the duration of soil oxygenation. To test this, surface soil from the Luquillo Forest, Puerto Rico, was subjected to fluctuating redox conditions with an anoxic interval of 6 days followed by oxic intervals of either 8, 24, or 72 h. Shorter oxic intervals enhanced Fe reduction, while longer oxic intervals enhanced CH 4 emissions. As O 2 exposure decreased from 72 to 8 h, Fe reduction rates increased from 0.12 ± 0.02 to 0.26 ± 0.05 mmol kg –1 h –1 , whereas cumulative CH 4 decreased from 44.0 ± 4.7 to 12.7 ± 4.6 μmol kg –1 . 13 C-amino acid spikes were preferentially incorporated into the DNA of iron reducers (Anaeromyxobacter sp.) in the shorter oxic treatment (8 h vs 24 h), suggesting that Fe reducers are less inhibited by shorter periods of oxidation. Conversely, longer oxygen pulses appear to suppress Fe reducers more than methanogens, leading to increased CH 4 emissions. These findings highlight the role of the redox oscillation length in modulating biogeochemical processes and greenhouse gas emissions in soils.

54 ENVIRONMENTAL SCIENCES↗

On Alfvénic turbulence of solar wind streams observed by Solar Orbiter during March 2022 perihelion and their source regions

It has been recently accepted that the standard classification of the solar wind solely according to flow speed is outdated, and particular interest has been devoted to the study of the origin and evolution of so-called Alfvénic slow solar wind streams and to what extent such streams resemble or differ from fast wind. In March 2022, Solar Orbiter completed its first nominal phase perihelion passage. During this interval, it observed several Alfvénic streams, allowing for characterization of fluctuations in three slow wind intervals (AS1-AS3) and comparison with a fast wind stream (F) at almost the same heliocentric distance. This work makes use of Solar Orbiter plasma parameters from the Solar Wind Analyzer (SWA) and magnetic field measurements from the magnetometer (MAG). The magnetic connectivity to the solar sources of selected solar wind intervals was reconstructed using a ballistic extrapolation based on measured solar wind speed down to the (spherical) source surface at 2.5 R s below which a potential field extrapolation was used to map back to the Sun. The source regions were identified using SDO/AIA observations. A spectral analysis of in situ measured magnetic field and velocity fluctuations was performed to characterize correlations, Alfvénicity, normalized cross-helicity, and residual energy in the frequency domain as well as intermittency of the fluctuations and spectral energy transfer rate estimated via mixed third-order moments. A machine learning technique was used to separate proton core, proton beam, and alpha particles and to study v − b correlations for the different ion populations in order to evaluate the role played by each population in determining the Alfvénic content of solar wind fluctuations. The comparison between fast wind and Alfvénic slow wind intervals highlights the differences between the two solar wind regimes: The fast wind is characterized by larger amplitude fluctuations, and magnetic and velocity fluctuations are closer to equipartition of energy. In fact the Alfvénic slow wind streams appear to be on a spectrum of wind types, with AS1, originating from open field lines neighboring active regions and displaying similarities with the fast wind in terms of fluctuation amplitude and turbulence characteristics, but not with respect to the alpha particles and proton beams. The other two slow streams differed both in their sources as well as plasma characteristics, with AS2 coming from the expansion of a narrow coronal hole corridor and AS3 from a region straddling a pseudostreamer. The latter displayed the coldest and highest density but the slowest stream with the smallest fluctuation amplitude and greatest magnetic energy excess. It also showed the largest scatter in proton beam speeds and the greatest difference in speed between proton beam and alpha particles. This study shows how the old fast–slow solar wind dichotomy, already called into question by the observations of slower Alfvénic solar wind streams, should further be refined, as the Alfvénic slow wind, originating in different solar wind regions, show significant differences in density, temperature, and proton and alpha-particle properties in the inner heliosphere. The observations presented here provide the starting point for a better understanding of the origin and evolution of different solar wind streams as well as the evolving turbulence contained within.

magnetohydrodynamics (MHD)↗

Laser ion source with a double pulse laser system

To extend an ion beam pulse of a laser ion source, multiple laser shots could be used. To check the feasibility of this idea, we tested double laser irradiations on an iron target. When the interval of the two laser shots is longer than 10 {mu}s, the obtained ion current profile was expressed as a sum of two individual expanded laser plasmas. However, if the interval is too close, a current reduction was observed. This technique can be effectively applied to low charge state ion production.

43 PARTICLE ACCELERATORS↗

Calcium and lithium ion production for laser ion source

Calcium and lithium ion beams are required by NASA Space Radiation Laboratory at Brookhaven National Laboratory to simulate the effects of cosmic radiation. To identify the difficulties in providing such highly reactive materials as laser targets, both species were experimentally tested. Plate shaped lithium and calcium targets were fabricated to create ablation plasmas with a 6 ns 1064 nm neodymium-doped yttrium aluminum garnet laser. We found significant oxygen contamination in both the Ca and Li high charge state beams due to the rapid oxidation of the surfaces. A large spot size, low power density laser was used to create low charge state beams without scanning the targets. The low charge state Ca beam did not have any apparent oxygen contamination, showing the potential to clean the target entirely of oxide with a low power beam once in the chamber. The Li target was clearly still oxidizing in the chamber after each low power shot. To measure the rate of oxidation, we shot the low power laser at the target repeatedly at 10 s, 30 s, 60 s, and 120 s interval lengths, showing a linear relation between the interval time and the amount of oxygen in the beam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PROBABILISTIC MODEL OF BEAM–PLASMA INTERACTION IN RANDOMLY INHOMOGENEOUS PLASMA

We propose a new model that describes beam–plasma interaction in the presence of random density fluctuations with a known probability distribution. We use the property that, for the given frequency, the probability distribution of the density fluctuations uniquely determines the probability distribution of the phase velocity of waves. We present the system as discrete and consisting of small, equal spatial intervals with a linear density profile. This approach allows one to estimate variations in wave energy density and particle velocity, depending on the density gradient on any small spatial interval. Because the characteristic time for the evolution of the electron distribution function and the wave energy is much longer than the time required for a single wave–particle resonant interaction over a small interval, we determine the description for the relaxation process in terms of averaged quantities. We derive a system of equations, similar to the quasi-linear approximation, with the conventional velocity diffusion coefficient D and the wave growth rate γ replaced by the average in phase space, by making use of the probability distribution for phase velocities and by assuming that the interaction in each interval is independent of previous interactions. Functions D and γ are completely determined by the distribution function for the amplitudes of the fluctuations. For the Gaussian distribution of the density fluctuations, we show that the relaxation process is determined by the ratio of beam velocity to plasma thermal velocity, the dispersion of the fluctuations, and the width of the beam in the velocity space.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

THE SECOND FERMI LARGE AREA TELESCOPE CATALOG OF GAMMA-RAY PULSARS

This catalog summarizes 117 high-confidence ≥0.1 GeV gamma-ray pulsar detections using three years of data acquired by the Large Area Telescope (LAT) on the Fermi satellite. Half are neutron stars discovered using LAT data through periodicity searches in gamma-ray and radio data around LAT unassociated source positions. The 117 pulsars are evenly divided into three groups: millisecond pulsars, young radio-loud pulsars, and young radio-quiet pulsars. We characterize the pulse profiles and energy spectra and derive luminosities when distance information exists. Spectral analysis of the off-peak phase intervals indicates probable pulsar wind nebula emission for four pulsars, and off-peak magnetospheric emission for several young and millisecond pulsars. We compare the gamma-ray properties with those in the radio, optical, and X-ray bands. We provide flux limits for pulsars with no observed gamma-ray emission, highlighting a small number of gamma-faint, radio-loud pulsars. The large, varied gamma-ray pulsar sample constrains emission models. Fermi's selection biases complement those of radio surveys, enhancing comparisons with predicted population distributions.

79 ASTRONOMY AND ASTROPHYSICS↗

Atomic motion from the mean square displacement in a monatomic liquid

V-T theory is constructed in the many-body Hamiltonian formulation, and is being developed as a novel approach to liquid dynamics theory. In this theory the liquid atomic motion consists of two contributions, normal mode vibrations in a single representative potential energy valley, and transits, which carry the system across boundaries between valleys. The mean square displacement time correlation function (the MSD) is a direct measure of the atomic motion, and our goal is to determine if the V-T formalism can produce a physically sensible account of this motion. We employ molecular dynamics (MD) data for a system representing liquid Na, and find the motion evolves in three successive time intervals: on the first 'vibrational' interval, the vibrational motion alone gives a highly accurate account of the MD data; on the second 'crossover' interval, the vibrational MSD saturates to a constant while the transit motion builds up from zero; on the third 'random walk' interval, the transit motion produces a purely diffusive random walk of the vibrational equilibrium positions. Furthermore, this motional evolution agrees with, and adds refinement to, the MSD atomic motion as described by current liquid dynamics theories.

74 ATOMIC AND MOLECULAR PHYSICS↗

Statistical coverage for supersymmetric parameter estimation: a case study with direct detection of dark matter

Models of weak-scale supersymmetry offer viable dark matter (DM) candidates. Their parameter spaces are however rather large and complex, such that pinning down the actual parameter values from experimental data can depend strongly on the employed statistical framework and scanning algorithm. In frequentist parameter estimation, a central requirement for properly constructed confidence intervals is that they cover true parameter values, preferably at exactly the stated confidence level when experiments are repeated infinitely many times. Since most widely-used scanning techniques are optimised for Bayesian statistics, one needs to assess their abilities in providing correct confidence intervals in terms of the statistical coverage. Here we investigate this for the Constrained Minimal Supersymmetric Standard Model (CMSSM) when only constrained by data from direct searches for dark matter. We construct confidence intervals from one-dimensional profile likelihoods and study the coverage by generating several pseudo-experiments for a few benchmark sets of pseudo-true parameters. We use nested sampling to scan the parameter space and evaluate the coverage for the benchmarks when either flat or logarithmic priors are imposed on gaugino and scalar mass parameters. The sampling algorithm has been used in the configuration usually adopted for exploration of the Bayesian posterior. We observe both under- and over-coverage, which in some cases vary quite dramatically when benchmarks or priors are modified. We show how most of the variation can be explained as the impact of explicit priors as well as sampling effects, where the latter are indirectly imposed by physicality conditions. For comparison, we also evaluate the coverage for Bayesian credible intervals, and observe significant under-coverage in those cases.

79 ASTRONOMY AND ASTROPHYSICS↗

DISTRIBUTION OF MAGNETIC DISCONTINUITIES IN THE SOLAR WIND AND IN MAGNETOHYDRODYNAMIC TURBULENCE

The statistical properties of magnetic discontinuities in the solar wind are investigated by measuring fluctuations in the magnetic field direction, given by the rotation {Delta}{theta} that the magnetic field vector undergoes during time interval {Delta}t. We show that the probability density function, P({Delta}{theta}), can be described by a simple model in which the magnetic field vector purely rotates with a relative increment {Delta}B/B that is lognormally distributed. We find that the probability density function of increments, P({Delta}B/B), has a remarkable scaling property: the normalized variable x = ({Delta}B/B) {center_dot} ({Delta}t/{Delta}t{sub 0}){sup -{alpha}} has a universal lognormal distribution for all time intervals {Delta}t. We then compare measurements from the solar wind with those from direct numerical simulations of magnetohydrodynamic (MHD) turbulence. We find good agreement for P({Delta}{theta}) obtained in the two cases when the magnetic guide field to fluctuations ratio B{sub 0}/b{sub rms} is chosen accordingly. However, the scale invariance of P({Delta}B/B) is broken in the MHD simulations with relatively limited inertial interval, which causes P({Delta}{theta}) to scale with measurement interval differently than in the solar wind.

79 ASTRONOMY AND ASTROPHYSICS↗

Characterizing the effect of incrementally increasing dry bulb temperature on linear and nonlinear measures of heart rate variability in nonpregnant, mid-gestation, and late-gestation sows

Abstract Characterizing the sow physiological response to an increased heat load is essential for effective heat stress mitigation. The study objective was to characterize the effects of a 400-min heating episode on sow heart rate variability (HRV) at different reproductive stages. HRV is a commonly used noninvasive proxy measure of autonomic function. Twenty-seven sows were enrolled in the study according to their gestation stage at time of selection: 1) nonpregnant (NP; n = 7), 2) mid-gestation (MID; 57.3 ± 11.8 d gestation; n = 11), and 3) late-gestation (LATE; 98.8 ± 4.9 d gestation; n = 8). The HRV data utilized in the study were collected from each pig as the dry bulb temperature in the room increased incrementally from 19.84 ± 2.15 °C to 35.54 ± 0.43 °C (range: 17.1–37.5 °C) over a 400-min period. After data collection, one 5-min set of continuous heart rate data were identified per pig for each of nine temperature intervals (19–20.99, 21–22.99, 23–24.99, 25–26.99, 27–28.99, 29–30.99, 31–32.99, 33–34.99, and 35–36.99 °C). Mean inter-beat interval length (RR), standard deviation of r-r intervals (SDNN), root mean square of successive differences (RMSSD), high frequency spectral power (HF), sample entropy (SampEn), short-term detrended fluctuation analysis (DFAα1), and three measures (%REC, DET, LMEAN) derived from recurrence quantification analysis were calculated for each data set. All data were analyzed using the PROC GLIMMIX procedure in SAS 9.4. Overall, LATE sows exhibited lower RR than NP sows (P < 0.01). The standard deviation of r–r intervals and RMSSD differed between each group (P < 0.01), with LATE sows exhibiting the lowest SDNN and RMSSD and NP sows exhibiting the greatest SDNN and RMSSD. Late-gestation sows exhibited lower HF than both MID and NP sows (P < 0.0001), greater DFA values than NP sows (P = 0.05), and greater DET compared to MID sows (P = 0.001). Late-gestation also sows exhibited greater %REC and LMEAN compared to MID (P < 0.01) and NP sows (all P < 0.01). In conclusion, LATE sows exhibited indicators of greater autonomic stress throughout the heating period compared to MID and NP sows. However, temperature by treatment interactions were not detected as dry bulb increased. Future studies are needed to fully elucidate the effect of gestational stage and increasing dry bulb temperature on sow HRV.

Agriculture↗

Generalized echo squeezing protocol with near-Heisenberg-limit sensitivity and strong robustness against detection noise and variation in squeezing parameter

We present a generalized echo squeezing protocol (GESP) as a generalization of the Schrödinger cat state protocol with the value of the squeezing parameter being an arbitrary number rather than π / 2 . We show analytically that over a very broad range of the squeezing parameter the sensitivity of the GESP reaches the Heisenberg limit within a factor of 2 . For a large number of atoms, N , this plateau interval is almost the whole range from zero to π / 2 , and the sensitivity is independent of the parity of N . Therefore, it is possible to operate a sensor over a wide interval of the squeezing parameter without changing the sensitivity. This is to be contrasted with the conventional echo squeezing protocol (CESP) which only works for a very small interval of the squeezing parameter. We also show that, in contrast to the CESP, the sensitivity of the GESP is close to the quantum Cramér-Rao bound over the whole range of the squeezing parameter, indicating that the phase-shift information contained in the quantum state is near-optimally extracted. We find that the enhancement in sensitivity in the case of the GESP is due to a combination of two parameters: the phase magnification factor (PMF) and the noise amplification factor (NAF). As the value of the squeezing parameter increases, both PMF and NAF increase, while keeping the ratio of the PMF to the NAF essentially constant, yielding a net enhancement of sensitivity at the Heisenberg limit within a factor of 2 over the whole plateau interval. An important consequence of this behavior is that the robustness of the GESP against detection noise easily exceeds that of the CESP for a broad range of values of the squeezing parameter. As such, in the context of an experimental study, it should be possible to achieve a net enhancement in sensitivity higher than that for the CESP, under typical conditions where detection noise exceeds the quantum projection noise of an unsqueezed state with the same number of atoms. Finally, we consider the fragility of the GESP against decoherence mechanisms, and show how a balance between the fragility against the decoherence mechanisms and the robustness against detection noise would in practice determine the optimal choice of parameters for the GESP.

Li, Jinyang↗