Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image charge”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

VARIABLE STARS IN THE LARGE MAGELLANIC CLOUD GLOBULAR CLUSTER NGC 2257. I. RESULTS BASED ON 2007-2008 B, V PHOTOMETRY

The variable stars in the Large Magellanic Cloud star cluster NGC 2257 are reinvestigated using photometry (to {approx}20th mag) of over 400 new B, V CCD images taken with the CTIO 0.9 m telescope on 14 nights in 2007 December and 2008 January. New period searches have been made using two independent algorithms (CLEAN, Period04); the resultant periods of most of the stars are consistent with the pulsation periods derived previously, and where there are discrepancies these have been resolved. For the B and V light curves, accurate Fourier coefficients and parameters are given. Six new variable stars have been discovered (V45-50), including a bright candidate long-period variable star showing secondary oscillations (V45) and two anomalously bright RRc stars (V48 and V50), which are shown to be brightened and reddened by nearby red giant stars. Also discovered among the previously known variable stars are three double-mode RR Lyrae stars (V8, V16, and V34) and several Blazhko variables. Archival Hubble Space Telescope images and the photometry by Johnson et al. have been used to define better the properties of the most crowded variable stars. The total number of cluster variable stars now stands at forty-seven: 23 RRab stars, four of which show Blazhko amplitude variations; 20 RRc stars, one showing clear Blazhko variations and another showing possible Blazhko variations; the three RRd stars, all having the dominant period {approx}0.36 day and period ratios P {sub 1}/P {sub 0} {approx}0.7450; and an LPV star located near the tip of the red giant branch. A comparison of the RRd stars with those in other environments shows them to be most similar to those in IC4499.

79 ASTRONOMY AND ASTROPHYSICS↗

The Hitomi X-Ray Observatory, Part 2

When it was launched on 17 February 2016, the Hitomi X-ray Observatory carried four kinds of new-generation x-ray instruments—the Soft X-ray Spectrometer (SXS), the Soft X-ray Imager (SXI), the Hard X-ray Imager (HXI), and the Soft Gamma-ray Detector (SGD). All four instruments were turned on and were in the process of activation at the time of loss of contact on 26 March 2016. In the time it was operational, Hitomi was able to provide researchers with a trove of ground-breaking scientific results. Initial results demonstrated that the instruments were meeting or exceeding requirements and that Hitomi was on its way to pioneering a new era of broad-band and high-resolution x-ray spectroscopy. The results published here summarize the in-flight instrument performance, calibration, and data processing accomplishments of the observatory. Of the papers accepted for publication in this special section, 17 were presented in Part 1 in the January-March 2018 issue of JATIS (Journal of Astronomical Telescopes, Instruments, and Systems). Ten more papers are presented here as Part 2 in the April-June 2018 issue. These papers cover the detailed in-flight performance of the four state-of the-art instruments on-board the Hitomi X-Ray Observatory. These instruments were extremely diverse in their design and principles of operation, ranging from low temperature x-ray calorimeters for high-resolution spectroscopy, CCDs (Charge-Coupled Devices) for wide field imaging, high fill-factor grazing incidence x-ray optics, including multilayer x-ray optics and silicon strip and CdTe strip detectors for high-energy imaging, and a Si/CdTe Compton cameras for extending the bandpass out to 600 kiloelectronvolts. All of these instruments operated as expected and for sufficient time to validate their operating principles and carry out first light scientific investigations, published elsewhere. Collectively, these instruments, all co-aligned and operated simultaneously, provided a tool for astronomers with unprecedented resolution and broadband sensitivity for investigating high-energy processes throughout the universe. These papers serve as part of the Hitomi legacy and will guide the next generation of instruments planned for future missions.

Kelley, Richard L.↗

N-Type delta Doping of High-Purity Silicon Imaging Arrays

A process for n-type (electron-donor) delta doping has shown promise as a means of modifying back-illuminated image detectors made from n-doped high-purity silicon to enable them to detect high-energy photons (ultraviolet and x-rays) and low-energy charged particles (electrons and ions). This process is applicable to imaging detectors of several types, including charge-coupled devices, hybrid devices, and complementary metal oxide/semiconductor detector arrays. Delta doping is so named because its density-vs.-depth characteristic is reminiscent of the Dirac delta function (impulse function): the dopant is highly concentrated in a very thin layer. Preferably, the dopant is concentrated in one or at most two atomic layers in a crystal plane and, therefore, delta doping is also known as atomic-plane doping. The use of doping to enable detection of high-energy photons and low-energy particles was reported in several prior NASA Tech Briefs articles. As described in more detail in those articles, the main benefit afforded by delta doping of a back-illuminated silicon detector is to eliminate a "dead" layer at the back surface of the silicon wherein high-energy photons and low-energy particles are absorbed without detection. An additional benefit is that the delta-doped layer can serve as a back-side electrical contact. Delta doping of p-type silicon detectors is well established. The development of the present process addresses concerns specific to the delta doping of high-purity silicon detectors, which are typically n-type. The present process involves relatively low temperatures, is fully compatible with other processes used to fabricate the detectors, and does not entail interruption of those processes. Indeed, this process can be the last stage in the fabrication of an imaging detector that has, in all other respects, already been fully processed, including metallized. This process includes molecular-beam epitaxy (MBE) for deposition of three layers, including metallization. The success of the process depends on accurate temperature control, surface treatment, growth of high-quality crystalline silicon, and precise control of thicknesses of layers. MBE affords the necessary nanometer- scale control of the placement of atoms for delta doping. More specifically, the process consists of MBE deposition of a thin silicon buffer layer, the n-type delta doping layer, and a thin silicon cap layer. The n dopant selected for initial experiments was antimony, but other n dopants as (phosphorus or arsenic) could be used. All n-type dopants in silicon tend to surface-segregate during growth, leading to a broadened dopant-concentration- versus-depth profile. In order to keep the profile as narrow as possible, the substrate temperature is held below 300 C during deposition of the silicon cap layer onto the antimony delta layer. The deposition of silicon includes a silicon- surface-preparation step, involving H-termination, that enables the growth of high-quality crystalline silicon at the relatively low temperature with close to full electrical activation of donors in the surface layer.

Blacksberg, Jordana↗

Studying single-electron traps in newly fabricated Skipper-CCDs for the Oscura experiment using the pocket-pumping technique

Understanding and characterizing very low-energy (⁠ ∼eV) background sources is a must in rare-event searches. Oscura, an experiment aiming to probe electron recoils from sub-GeV dark matter using a 10 kg skipper-CCD detector, has recently fabricated its first two batches of sensors. In this work, we present the characterization of defects/contaminants identified in the buried-channel region of these newly fabricated skipper-CCDs. These defects/contaminants produce deferred charge from trap emission in the images next to particle tracks, which can be spatially resolved due to the sub-electron resolution achieved with these sensors. Using the trap-pumping technique, we measured the energy and cross section associated with these traps in three Oscura prototype sensors from different fabrication batches which underwent different gettering methods during fabrication. Results suggest that the type of defects/contaminants is more closely linked to the fabrication batch rather than to the gettering method used. The exposure-dependent single-electron rate (SER) of one of these sensors was measured ∼100 m underground, yielding (1.8±0.3)×10−3e−/pix/day at 131 K. The impact of the identified traps on the measured exposure-dependent SER is evaluated via a Monte Carlo simulation. Results suggest that the exposure-dependent SER of Oscura prototype sensors would be lower in lower background environments as expected.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Real-time probing of ultrafast residual charge dynamics

The temporal evolution of residual charges during laser ablation of metal and dielectric materials was investigated by measuring the correlated transient electric field using femtosecond electron shadow imaging and deflectometry. The results indicate that residual charges in metals can redistribute themselves almost instantly, abiding by the boundary conditions and Maxwell equations in the same way as they would at electrostatic equilibrium condition, but residual charges in dielectrics are confined within the excited area for hundreds of picoseconds and beyond. These observations provide an experimental support to the alleged Coulomb explosion phenomenon in previous studies as well as a reference for modeling residual charge dynamics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cometary spectroscopy and imaging

The objective is to investigate the spectroscopic and morphological characteristics of comets and selected minor planets over a wide range of heliocentric distances as they may suggest or constrain models of cometary processes, their formation environments and evolution. Direct images of all observable comets and 300-800 nm spectra of the brighter ones are obtained on a monthly basis with a charge coupled device spectrograph-camera. The direct images may be used for astrometry, photometry, and studies of coma and tail morphology. In some cases, anisotropic dust emission can provide information on the nucleus spin vector. Spectra may provide data on strengths of the principle emission for comparison of gas/dust ratios of a large sample of comets. Long integrations of minor planets in comet-like and nearby orbits are made to search for faint comae.

Larson, Stephen M.↗

Magnetic Imaging with Spin Defects in Hexagonal Boron Nitride

Optically active spin defects hosted in hexagonal boron nitride (ℎ-BN) are promising candidates for the development of a two-dimensional (2D) quantum sensing unit. Here, we demonstrate quantitative magnetic imaging with ℎ-BN flakes doped with negatively charged boron-vacancy ($V^{-}_{B}$) centers through neutron irradiation. As a proof-of-concept, we image the magnetic field produced by Cr⁢Te 2 , a van der Waals ferromagnet with a Curie temperature slightly above 300 K. Compared to other quantum sensors embedded in 3D materials, the advantages of the ℎ-BN-based magnetic sensor described in this work are its ease of use, high flexibility, and, more importantly, its ability to be placed in close proximity to a target sample. Further, such a sensing unit will likely find numerous applications in 2D materials research by offering a simple way to probe the physics of van der Waals heterostructures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Intact, Commercial Lithium-Polymer Batteries: Spatially Resolved Grating-Based Interferometry Imaging, Bragg Edge Imaging, and Neutron Diffraction

We survey several neutron imaging and diffraction methods for non-destructive testing and evaluation of intact, commercial lithium-ion batteries. Specifically, far-field interferometry was explored as an option to probe a wide range of autocorrelation lengths within the batteries via neutron imaging. The dark-field interferometry images change remarkably from fresh to worn batteries, and from charged to discharged batteries. When attempting to search for visual evidence of battery degradation, neutron Talbot-Lau grating interferometry exposed battery layering and particle scattering through dark-field imaging. Bragg edge imaging also reveals battery wear and state of charge. Neutron diffraction observed chemical changes between fresh and worn, charged and discharged batteries. However, the utility of these methods, for commercial batteries, is dependent upon battery size and shape, with 19 to 43 mAh prismatic batteries proving most convenient for these experimental methods. This study reports some of the first spatially resolved, small angle scattering (dark-field) images showing battery degradation.

36 MATERIALS SCIENCE↗

High sensitivity imaging Thomson scattering for low temperature plasma

A highly sensitive imaging Thomson scattering system was developed for low temperature (0.1-10 eV) plasma applications at the Pilot-PSI linear plasma generator. The essential parts of the diagnostic are a neodymium doped yttrium aluminum garnet laser operating at the second harmonic (532 nm), a laser beam line with a unique stray light suppression system and a detection branch consisting of a Littrow spectrometer equipped with an efficient detector based on a ''Generation III'' image intensifier combined with an intensified charged coupled device camera. The system is capable of measuring electron density and temperature profiles of a plasma column of 30 mm in diameter with a spatial resolution of 0.6 mm and an observational error of 3% in the electron density (n{sub e}) and 6% in the electron temperature (T{sub e}) at n{sub e}=4x10{sup 19} m{sup -3}. This is achievable at an accumulated laser input energy of 11 J (from 30 laser pulses at 10 Hz repetition frequency). The stray light contribution is below 9x10{sup 17} m{sup -3} in electron density equivalents by the application of a unique stray light suppression system. The amount of laser energy that is required for a n{sub e} and T{sub e} measurement is 7x10{sup 20}/n{sub e} J, which means that single shot measurements are possible for n{sub e}>2x10{sup 21} m{sup -3}.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Integrating 128-element linear imager for the 1 to 5 microns region

Useful charge integration has been achieved in high quality photovoltaic InSb diodes when combined with a FET multiplexing (MUX) scheme. An experimental detector assembly with a linear array of 128 InSb diodes coupled to a FEX MUX has been developed. The first stage J-FET preamp, pixel reset switch, MUX, and the InSb array are contained in a hybrid microcircuit of compact dimensions. A low noise preamplifier topology which capitalizes on the low video line capacitance inherent with hybrid fabrication techniques is also utilized. Measurements indicate a signal-to-noise ratio of over 1000:1 and response uniformity of + or - 2 percent. Sample images show subtle detail which supports the estimated radiometric sensitivity of 0.01 K.

Bailey, G. C.↗

A Wide Field of View Plasma Spectrometer

Here we present a fundamentally new type of space plasma spectrometer, the wide field of view plasma spectrometer, whose field of view is >1.25π ster using fewer resources than traditional methods. The enabling component is analogous to a pinhole camera with an electrostatic energy-angle filter at the image plane. Particle energy-per-charge is selected with a tunable bias voltage applied to the filter plate relative to the pinhole aperture plate. For a given bias voltage, charged particles from different directions are focused by different angles to different locations. Particles with appropriate locations and angles can transit the filter plate and are measured using a microchannel plate detector with a position-sensitive anode. Full energy and angle coverage are obtained using a single high-voltage power supply, resulting in considerable resource savings and allowing measurements at fast timescales. Lastly, we present laboratory prototype measurements and simulations demonstrating the instrument concept and discuss optimizations of the instrument design for application to space measurements.

47 OTHER INSTRUMENTATION↗

Direct observation of strain-enhanced hydrogen segregation and failure at high-angle grain boundaries in nickel

Understanding the mechanisms underlying hydrogen embrittlement remains difficult, even in single-element metals. Both microstructure and stress state influence hydrogen distribution in metals and alloys, which impacts deformation and failure. Here, in this work, we use in-situ Kelvin probe force microscopy (KPFM) to monitor the hydrogen distribution in pure nickel over time at 1.1 % and 3.5 % strain. The sample strained to 3.5 % results in preferential hydrogen segregation to high-angle grain boundaries whereas the sample strained to 1.1 % does not exhibit preferential hydrogen segregation. Optical digital image correlation (DIC) shows that hydrogen charging results in both localized and reduced strains during tensile testing of a notched sample. Later stages of deformation and failure (e.g. microcracking) are studied by using in-situ transmission X-ray microscopy (TXM). TXM reveals nanoscale structural changes to a propagating crack in a hydrogen environment. Localized void growth and secondary cracking occur at grain boundaries near the primary crack front. Correlative electron backscattering diffraction (EBSD) is used to relate the cracking at grain boundaries to the hydrogen segregation observed in KPFM. These findings are unified in a proposed hydrogen embrittlement mechanism that describes the interaction of hydrogen with grain boundaries, and the role of grain boundaries in hydrogen embrittlement.

Grain boundary fracture↗

A convenient method of preparing gene vector for real time monitoring transfection process based on the quantum dots

Highlights: ► An easy and direct way to prepare QDs–DNA complexes was developed. ► Surface charge of QDs was tuned with different ratio of amino and glycolate. ► Transfection efficiency was dependent on the surface zeta potentials of QDs. ► Cellular toxicity of this gene vectors is much lower than commercial liposome. ► Whole intracellular behavior of QDs–DNA complexes can be monitored in real time. -- Abstract: Nanoparticle carrier has been developed by combining water-soluble quantum dots and plasmid DNA expressed enhanced green fluorescent protein (EGFP) in a convenient and direct way. First the QDs with different surface charges were obtained by coating with amino and carboxyl terminals at different ratios. Then plasmid DNA was conjugated to QDs via electrostatic interaction. The resultant QDs–DNA complexes showed enhanced resistance to DNase I digestion. The following transfection experiments demonstrated that the transfection efficiency was dependent on the surface charges on QDs. The real time imaging of the transfection process showed that the nanoparticles experienced binding, penetrating the cell membrane and entering cytoplasm in the first 6 h of transfection. The green fluorescence of EGFP began to appear after 18 h transfection and plasmid DNA was fully expressed in the following 6 h. This new QDs–DNA platform showed great potential as new gene delivery carrier.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Development of the FASPAX IC for a high burst rate X-ray imager with very high dynamic range ( 1 0 5 ) capability in small pixels

Development of the FASPAX IC for a high burst rate X-ray imager with very high dynamic range (10 5 ) capability in small pixels. The technique of current splitting is presented as part of an integrated circuit development for an X-ray imager. This method enables integration of charge signals of unprecedented magnitude in small pixels, achieving a dynamic range of 10 5 . Results from two front end prototypes are given and a final optimized design is proposed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Visualizing Charge Transport and Nanoscale Electrochemistry by Hyperspectral Kelvin Probe Force Microscopy

Charge-transport and electrochemical processes are heavily influenced by the local microstructure. Kelvin probe force microscopy (KPFM) is a widely used technique to map electrochemical potentials at the nanometer scale; however, it offers little information on local charge dynamics. In this study, we implement a hyperspectral KPFM approach for spatially mapping bias-dependent charge dynamics in timescales ranging from the sub-millisecond to the second regime. As a proof of principle, we investigate the role mobile surface charges play in a three-unit-cell LaAlO 3 /SrTiO 3 oxide heterostructure. We explore machine learning approaches to assist with visualization, pattern recognition, and interpretation of the information-rich data sets. Linear unmixing methods reveal hidden bias-dependent interfacial processes, most likely water splitting, which are essentially unnoticed by functional fitting of the dynamic response alone. Hyperspectral KPFM will be beneficial for investigating nanoscale charge transport and local reactivity in systems involving a possible combination of electronic, ionic, and electrochemical phenomena.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Stability of Calcium Ion Battery Electrolytes: Predictions from Ab Initio Molecular Dynamics Simulations

Multivalent batteries, such as magnesium-ion, calcium-ion, and zinc-ion batteries, have attracted significant attention as next-generation electrochemical energy storage devices to complement conventional lithium-ion batteries (LIBs). Among them, calcium-ion batteries (CIBs) are the least explored due to the difficult reversible Ca deposition-dissolution. In this work, we examined the stability of four different Ca salts with weakly coordinating anions and three different solvents commonly employed in existing battery technologies to identify suitable candidates for CIBs. By employing Born-Oppenheimer molecular dynamics (BOMD) simulations on salt-Ca and solvent-Ca interfaces, we find that the tetraglyme solvent and carborane salt are promising candidates for CIBs. Due to the strong reducing nature of the calcium surface, the other salts and solvents readily decompose. Further, we explain the microscopic mechanisms of salt/solvent decomposition on the Ca surface using time-dependent projected density of states, time-dependent charge-transfer plots, and climbing-image nudged elastic band calculations. Collectively, this work presents the first mechanistic assessment of the dynamical stability of candidate salts and solvents on a Ca surface using BOMD simulations, and provides a predictive path toward designing stable electrolytes for CIBs.

Born-Oppenheimer molecular dynamics↗

New Products

No abstract prepared.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simultaneous translational temperature measurements of different atomic species in plasma flows using scanning Fabry-Perot interferometry

A revised scientific instrument to measure simultaneously kinetic temperatures of different atoms from their optical emission profile is reported. Emission lines are simultaneously detected using one single scanning Fabry-Perot-interferometer (FPI) for a combined spectroscopic setup to acquire different emission lines simultaneously. The setup consists in a commercial Czerny-Turner spectrometer configuration which is combined with a scanning Fabry-Perot interferometer. The fast image acquisition mode of an intensified charge coupled device camera allows the detection of a wavelength interval of interest continuously while acquiring the highly resolved line during the scan of the FPI ramp. Results using this new setup are presented for the simultaneous detection of atomic nitrogen and oxygen in a high enthalpy air plasma flow as used for atmospheric re-entry research and their respective kinetic temperatures derived from the measured line profiles. The paper presents the experimental setup, the calibration procedure, and an exemplary result. The determined temperatures are different, a finding that has been published so far as due to a drawback of the experimental setup of sequential measurements, and which has now to be investigated in more detail.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗