A novel photonic Doppler velocimetry for transverse velocity measurement

A fiber interferometry for transverse velocity measurement has been developed. This diagnostic is similar to photonic Doppler velocimetry in the way in which laser propagates and couples. The interferometer mainly consists of a fiber coupler, an emitting probe, and two receiving probes. A pair of scattered laser beams mix in the coupler and generates fringes with frequency proportional to transverse velocity. Measurement of transverse velocity is independent of longitudinal velocity. The feasibility of the technique has been verified by rotating wheel experiment and shock loading experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Molecular beam epitaxy of high structural quality Bi{sub 2}Se{sub 3} on lattice matched InP(111) substrates

Epitaxial layers of the topological insulator Bi{sub 2}Se{sub 3} have been grown by molecular beam epitaxy on laterally lattice-matched InP(111)B substrates. High resolution X-ray diffraction shows a significant improvement of Bi{sub 2}Se{sub 3} crystal quality compared to layers deposited on other substrates. The measured full width at half maximum of the rocking curve is {Delta}{omega}=13 arc sec, and the ({omega}-2{theta}) scans exhibit clear layer thickness fringes. Atomic force microscope images show triangular twin domains with sizes increasing with layer thickness. The structural quality of the domains is confirmed on the microscopic level by transmission electron microscopy.

36 MATERIALS SCIENCE↗

Mapping magnetic fields of Fe{sub 3}O{sub 4} nanosphere assemblies by electron holography

Crystalline Fe{sub 3}O{sub 4} nanospheres with averaged diameters of 150 nm have been synthesized by a facile solvothermal method and characterized using transmission electron microscopy and electron holography. The nanospheres can self-assemble into either chain-like or ring-like shapes with sizes of a few micrometers, where large magnetic moments are found for individual particles at the remanent state and lead to strong fringing field in vicinity of the assemblies. Magnetic dipolar moments can be aligned both within and out of the sample plane, with a typical length scale on the order of 500 nm.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Experimental energy resolution of a paracentric hemispherical deflector analyzer for different entry positions and bias

A specially designed hemispherical deflector analyzer (HDA) with 5-element input lens having a movable entry position R{sub 0} suitable for electron energy analysis in atomic collisions was constructed and tested. The energy resolution of the HDA was experimentally determined for three different entry positions R{sub 0}= 84, 100, 112 mm as a function of the nominal entry potential V(R{sub 0}) under pre-retardation conditions. The resolution for the (conventional) entry at the mean radius R{sub 0}= 100 mm was found to be a factor of 1.6-2 times worse than the resolution for the two (paracentric) positions R{sub 0}= 84 and 112 mm at particular values of V(R{sub 0}). These results provide the first experimental verification and a proof of principle of the utility of such a paracentric HDA, while demonstrating its advantages over the conventional HDA: greater dispersion with reduced angular aberrations resulting in better energy resolution without the use of any additional fringing field correction electrodes. Supporting simulations of the entire lens plus HDA spectrometer are also provided and mostly found to be within 20%-30% of experimental values. The paracentric HDA is expected to provide a lower cost and/or more compact alternative to the conventional HDA particularly useful in modern applications utilizing a position sensitive detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Conceptual design of the tangentially viewing combined interferometer-polarimeter for ITER density measurements

One of the systems planned for the measurement of electron density in ITER is a multi-channel tangentially viewing combined interferometer-polarimeter (TIP). This work discusses the current status of the design, including a preliminary optical table layout, calibration options, error sources, and performance projections based on a CO{sub 2}/CO laser system. In the current design, two-color interferometry is carried out at 10.59 {mu}m and 5.42 {mu}m and a separate polarimetry measurement of the plasma induced Faraday effect, utilizing the rotating wave technique, is made at 10.59 {mu}m. The inclusion of polarimetry provides an independent measure of the electron density and can also be used to correct the conventional two-color interferometer for fringe skips at all densities, up to and beyond the Greenwald limit. The system features five chords with independent first mirrors to reduce risks associated with deposition, erosion, etc., and a common first wall hole to minimize penetration sizes. Simulations of performance for a projected ITER baseline discharge show the diagnostic will function as well as, or better than, comparable existing systems for feedback density control. Calculations also show that finite temperature effects will be significant in ITER even for moderate temperature plasmas and can lead to a significant underestimate of electron density. A secondary role TIP will fulfill is that of a density fluctuation diagnostic; using a toroidal Alfven eigenmode as an example, simulations show TIP will be extremely robust in this capacity and potentially able to resolve coherent mode fluctuations with perturbed densities as low as {delta}n/n Almost-Equal-To 10{sup -5}.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design and implementation of a 150 GHz single-channel millimeter wave interferometer on Joint TEXT tokamak

A simple, single-channel millimeter-wave interferometer system has been designed, fabricated, and installed on the J-TEXT tokamak. For the plasma density anticipated on J-TEXT, a solid-state source operating at 150 GHz has been chosen to minimize errors due to both vibration along the beam path and refraction in the plasma. The new aspect of the interferometer design is to use a subharmonic mixer for detection with a frequency doubled 150 GHz source. It employs a single source which is bias-tuned and modulated with a sawtooth wave form up to 100 kHz in order to generate the intermediate frequency. The 12.5 GHz voltage-controlled oscillator is multiplied to 75 GHz before a final doubler raises it to 150 GHz. A portion of the 75 GHZ power is used for the local oscillator (LO) and is directly connected to the LO input of the subharmonic mixer. The phase is evaluated by a digital phase comparator using a software-based algorithm. Detection noise limits the minimum resolvable phase change with the interferometer to {+-}0.05 fringe, which corresponds to an averaged electron density change along the chord of {+-}1.1 Multiplication-Sign 10{sup 17} m{sup -2}. The maximum measurable electron density is expected to be {approx}9 Multiplication-Sign 10{sup 19} m{sup -3}. A comparison of preliminary results from the millimeter wave interferometer with that from the far-infrared hydrogen cyanide laser (wavelength of 337 {mu}m) interferometer shows good agreement during the pulse flat-top period. The millimeter wave interferometer system will be used as a part of the density feedback control system in the future.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nanostructural and electronic properties of polytypes in InN nanocolumns

Transmission electron microscopy techniques and density functional theory calculations were employed to investigate the nanostructural and electronic properties of InN polytypes observed in InN nanocolumns, grown on Si(111) by molecular beam epitaxy. Moiré fringes and alternating hexagonal and cubic lattice stacking sequences along the c-axis, observed among the wurtzite layers, implied the presence of different structures embedded in the basic 2H structure of the nanocolumns. Quantitative electron diffraction analysis and high-resolution image simulations verified the coexistence of the wurtzite structure with the 4H, 6H, and the 3C zinc-blende structural polytypes. Total energies calculations established the 2H wurtzite structure as the most stable polytype. The band gap of all polytypes was found direct with the energies and the band gaps of the 4H (E{sub g} = 0.64 eV) and 6H (E{sub g} = 0.60 eV) structures calculated between the corresponding values of the 2H (E{sub g} = 0.75 eV) and 3C (E{sub g} = 0.49 eV) basic structures. Theoretical and experimental analysis showed that at the initial stages of growth InN nanocolumns were under tensile strain along both the basal plane and growth direction. Structural polytypes were then introduced in the form of embedded inclusions to accommodate the excess tensile strain along the growth direction, allowing the entire process of polymorphism to be the dominant strain relaxation mechanism of InN nanocolumns. Moreover, the lattice and energetic properties and band gap values of InN polytypes showed a linear dependence on hexagonality, while the presence of polytypes led to a characteristic broadening of the photoluminescence emission peak toward lower emission energies.

36 MATERIALS SCIENCE↗

Comparison of laser-based and monochromator-based thermodynamic temperature measurements

In this work, we describe comparisons between a laser-based and a monochromator-based radiance responsivity calibration of a radiation thermometer. The spectral selection of the radiation thermometer is performed using a spectrally broad photopic-response filter which was selected to minimize effects of convolution differences due to the spectral width of the laser-and the monochromator-based sources. The photopic-response filter is physically thick, which should also reduce possible interference fringes which can be problematic in the laser-based calibrations. We compare the radiance responsivities obtained using the two approaches and also compare the blackbody temperatures determined using the detector/monochromator based and the gold-point based calibration methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An extreme ultraviolet Michelson interferometer for experiments at free-electron lasers

We present a Michelson interferometer for 13.5 nm soft x-ray radiation. It is characterized in a proof-of-principle experiment using synchrotron radiation, where the temporal coherence is measured to be 13 fs. The curvature of the thin-film beam splitter membrane is derived from the observed fringe pattern. The applicability of this Michelson interferometer at intense free-electron lasers is investigated, particularly with respect to radiation damage. This study highlights the potential role of such Michelson interferometers in solid density plasma investigations using, for instance, extreme soft x-ray free-electron lasers. A setup using the Michelson interferometer for pseudo-Nomarski-interferometry is proposed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time resolved optical diagnostics of ZnO plasma plumes in air

We report dynamical evolution of laser ablated ZnO plasma plumes using interferometry and shadowgraphy; 2-D fast imaging and optical emission spectroscopy in air ambient at atmospheric pressure. Recorded interferograms using Nomarski interferometer and shadowgram images at various time delays show the presence of electrons and neutrals in the ablated plumes. The inference drawn from sign change of fringe shifts is consistent with two dimensional images of the plume and optical emission spectra at varying time delays with respect to ablating pulse. Zinc oxide plasma plumes are created by focusing 1.06 μm radiation on to ZnO target in air and 532 nm is used as probe beam.

36 MATERIALS SCIENCE↗

Chirped laser dispersion spectroscopy using a directly modulated quantum cascade laser

Chirped laser dispersion spectroscopy (CLaDS) utilizing direct modulation of a quantum cascade laser (QCL) is presented. By controlling the laser bias nearly single- and dual-sideband CLaDS operation can be realized in an extremely simplified optical setup with no external optical modulators. Capability of direct single-sideband modulation is a unique feature of QCLs that exhibit a low linewidth enhancement factor. The developed analytical model shows excellent agreement with the experimental, directly modulated CLaDS spectra. This method overcomes major technical limitations of mid-infrared CLaDS systems by allowing significantly higher modulation frequencies and eliminating optical fringes introduced by external modulators.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Improvement of extraction system geometry with suppression of possible Penning discharge ignition

During the past two years, a new ECR 2.45 GHz type ion source has been developed especially dedicated to intense light ion injector project like IPHI (Injecteur Proton Haute Intensité), IFMIF (International Fusion Materials Irradiation Facility), to reduce beam emittance at RFQ entrance by shortening the length of the LEBT. This new ALISES concept (Advanced Light Ion Source Extraction System) is based on the use of an additional LEBT short length solenoid very close to the extraction aperture. The fringe field of this new solenoid produces the needed magnetic field to create the ECR resonance in the plasma chamber. Such geometry allows first putting the solenoid at ground potential, while saving space in front of the extraction to move the first LEBT solenoid closer and focus earlier the intense extracted beam. During the commissioning of the source in 2011–2012, ALISES has produced about 20 mA extracted from a 6 mm diameter plasma extraction hole at 23 kV. But the magnetic configuration combined to the new extraction system geometry led to important Penning discharge conditions in the accelerator column. Lots of them have been eliminated by inserting glass pieces between electrodes to modify equipotential lines with unfavorable ExB vacuum zones where particles were produced and trapped. To study Penning discharge location, several 3D calculations have been performed with OPERA-3D/TOSCA code to simulate the possible production and trapping of electrons in the extraction system. The results obtained on different sources already built have shown very good agreement with sparks location observed experimentally on electrodes. The simulations results as well as experimental measurements are presented and solutions to prevent possible Penning discharge in future source geometries are established.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multifunctional Bi{sub 2}ZnOB{sub 2}O{sub 6} single crystals for second and third order nonlinear optical applications

Bi{sub 2}ZnOB{sub 2}O{sub 6} nonlinear optical single crystals were grown by means of the Kyropoulos method from stoichiometric melt. The second and third harmonic generation (SHG/THG) of Bi{sub 2}ZnOB{sub 2}O{sub 6} crystals were investigated by the SHG/THG Maker fringes technique. Moreover, SHG microscopy studies were carried out providing two-dimensional SHG images as a function of the incident laser polarization. The high nonlinear optical efficiency combined with the possibility to grow high quality crystals make Bi{sub 2}ZnOB{sub 2}O{sub 6} an excellent candidate for photonic applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Invited Article: Expanded and improved traceability of vibration measurements by laser interferometry

Traceability to the International System of Units has been established for vibration and shock measurements as specified in international document standards, recommendations, and regulations to ensure product quality, health, and safety. New and upgraded laser methods and techniques developed by national metrology institutes and by leading manufacturers in the past two decades have been swiftly specified as standard methods in the ISO 16063 series of international document standards. In ISO 16063-11:1999, three interferometric methods are specified for the primary calibration of vibration transducers (reference standard accelerometers) in a frequency range from 1 Hz to 10 kHz. In order to specify the same (modified) methods for the calibration of laser vibrometers (ISO 16063-41:2011), their applicability in an expanded frequency range was investigated. Steady-state sinusoidal vibrations were generated by piezoelectric actuators at specific frequencies up to 347 kHz (acceleration amplitudes up to 376 km/s{sup 2}). The displacement amplitude, adjusted by the special interferometric method of coincidence to 158.2 nm (quarter the wavelength of the He-Ne laser light), was measured by the standardized interferometric methods of fringe counting and sine-approximation. The deviations between the measurement results of the three interferometric methods applied simultaneously were smaller than 1 %. The limits of measurement uncertainty specified in ISO 16063-11 between 1 Hz to 10 kHz were kept up to frequencies, which are orders of magnitude greater; the uncertainty limit 0.5 % specified at the reference frequency 160 Hz was not exceeded at 160 kHz. The reported results were considered during the development of ISO 16063-41 by specifying the instrumentation and procedures for performing calibrations of rectilinear laser vibrometers in the frequency range typically between 0.4 Hz and 50 kHz—the interferometric methods may be applied within expanded frequency ranges using refined techniques and procedures. It is concluded that calibration frequencies up to 0.5 MHz are attainable in compliance with the first international document standard for the calibration of laser vibrometers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical probe investigation of laser ablated carbon plasma plume in nitrogen ambient

We report the study of carbon plasma produced using 1064 nm laser in nitrogen ambient at atmospheric pressure using 2-dimensional fast imaging of ablated plume, optical emission spectroscopy, and optical probe at 532 nm for interferometry and shadowgraphy. The dominance of C{sub 2} and CN molecules over ionic species at later stages of expanding carbon plasma plume is reported. The observed ring structure in shadowgrams and change in the direction of fringe shift from positive to negative in recorded interferograms are correlated with the relative abundance of different species in the plasma plume as function of time delay with respect to ablating pulse. An agreement in observed onset time of formation of clusters/atomic species or low ionic species using different diagnostic techniques has been reported.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Enhanced charge detection: Amplification factor, phase reversal and measurement time dependence

Studenikin et al. recently demonstrated a significant enhancement of the fringe contrast of coherent Landau-Zener-Stückelberg (LZS) oscillations between singlet S and triplet T+ two-spin states using a modified charge detection technique called enhanced charge detection (ECD). In this paper we explain the amplitude phase reversal and confirm the magnitude of the effect is consistent with our calibrations. We also show that the enhancement cannot be explained by a T{sub 1} effect.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Two-photon spectroscopy of excitons with entangled photons

The utility of quantum light as a spectroscopic tool is demonstrated for frequency-dispersed pump-probe, integrated pump-probe, and two-photon fluorescence signals which show Ramsey fringes. Simulations of the frequency-dispersed transmission of a broadband pulse of entangled photons interacting with a three-level model of matter reveal how the non-classical time-bandwidth properties of entangled photons can be used to disentangle congested spectra, and reveal otherwise unresolved features. Quantum light effects are most pronounced at weak intensities when entangled photon pairs are well separated, and are gradually diminished at higher intensities when different photon pairs overlap.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spatial coherence measurements of non-resonant and resonant high harmonics generated in laser ablation plumes

We present measurements of the spatial coherence of the high-order harmonics generated in laser-produced ablation plumes. Harmonics were generated using 4 fs, 775 nm pulses with peak intensity 3 × 10{sup 14} W cm{sup −2}. Double-slit fringe visibilities in the range of ≈0.6–0.75 were measured for non-resonant harmonics in carbon and resonantly enhanced harmonics in zinc and indium. These are somewhat higher than the visibility obtained for harmonics generated in argon gas under similar conditions. This is attributed to lower time-dependent ionization of the plasma ablation targets compared to argon during the high harmonics generation process.