Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “faults”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Transient Stability Analysis for Offshore Wind Power Plant Integration Planning Studies - Part I: Short Term Faults

Power system planning is the process of forecasting load demand and ensuring sufficient generation and reserve capacities over some planning horizon. This process includes investigation of steady-state and dynamic operation of power system of interest. This paper addresses the transient stability (also known as large-signal stability) analysis of power systems for offshore wind power plant integration planning studies. In particular, this study develops a comprehensive practical methodology to assess transient stability of power systems, including rotor angle stability, voltage stability and frequency response for all fault types for large scale power systems. This methodology considers variability of the offshore wind power plants as well as the type of any faulted components present and is applicable to the study of both short term and long term faults, though only short term faults are considered here (long term faults are treated sequentially in a companion paper). Furthermore, this paper considers the integration of offshore wind power plants into existing power systems and demonstrates the utility of this methodology through the examination of the specific case of integrating 1,000MW of offshore wind power into the FirstEnergy/PJM service territory using a realistic model of 63k-bus test system that represents the U.S. Eastern Interconnection.

17 WIND ENERGY↗

3D fault architecture controls the dynamism of earthquake swarms

The vibrant evolutionary patterns made by earthquake swarms are incompatible with standard, effectively two-dimensional (2D) models for general fault architecture. Here we leverage advances in earthquake monitoring with a deep-learning algorithm to image a fault zone hosting a 4-year-long swarm in southern California. We infer that fluids are naturally injected into the fault zone from below and diffuse through strike-parallel channels while triggering earthquakes. A permeability barrier initially limits up-dip swarm migration but ultimately is circumvented. This enables fluid migration within a shallower section of the fault with fundamentally different mechanical properties. Our observations provide high-resolution constraints on the processes by which swarms initiate, grow, and arrest. These findings illustrate how swarm evolution is strongly controlled by 3D variations in fault architecture.

58 GEOSCIENCES↗

Analysis of Microseismicity and Reactivated Fault Size to Assess the Potential for Felt Events by CO 2 Injection in the Illinois Basin

The results of monitoring of carbon dioxide (CO 2 ) injection at the Illinois Basin—Decatur Project (IBDP) and the companion Illinois Industrial Carbon Capture and Sequestration Sources (IL-ICCS) project—have shown that reservoir response to fluid pressure changes can vary significantly at different injection locations within the same reservoir. Predrill reservoir characterization is important to identify potentially seismogenic faults. However, interpretations of newly reprocessed 3D seismic reflection data illustrate the challenges related to their identification in a region dominated by faulting with small vertical offsets. Faults interpreted in the 3D seismic volume range from ~300 to 1200 m wide and are in the same size range as faults that could have been the source of historical events up to Mw 2.7 in central Illinois. The array of monitoring sensors that was installed for the IBDP continues to collect data, as injection operates in IL-ICCS, the second injection well. CO 2 injection rates for the IL-ICCS well are on average 1.7 times the rates injected in the IBDP well, but a significantly reduced rate of induced seismicity is observed. This article presents results of passive seismic monitoring for the duration of the project to date, integrating active and passive seismic data to develop a new interpretation of the subsurface structure at the Decatur site that explicitly identifies pathways for fluid flow into the basement leading to induced seismicity, and provides a geological explanation for the sharp reduction of induced seismicity during injection at higher rates into the second well. The use of seismic moment to estimate the length of seismogenic slip planes in the local subsurface suggests that faults large enough to produce felt seismicity are unlikely to be present at or near the Decatur site.

Geochemistry & Geophysics↗

Development of a Annual Air Handling Unit Fault Dataset for FDD Tools: Lessons Learned and Considerations for FDD Developers

As energy management and information systems (e.g., automated fault detection and diagnostics [AFDD] tools) become more prevalent in the commercial building stock, it is important to determine the effectiveness of these technologies by benchmarking their performance. The authors have been working to develop the largest publicly available dataset of HVAC fault data for performance benchmarking applications, covering the most common HVAC systems and designs including chiller plants, rooftop packaged units, dual duct air handling units and single duct air handling units. This study covers the development, modeling, and validation of a synthetic fault dataset for a single duct air handling unit (AHU), one of the most common HVAC configurations found in the commercial building stock. Despite this being a common system, real-world time series data are scarce and usually do not span a wide range of weather conditions. Due to this limitation, a detailed AHU model was employed to carry out annual simulations of numerous common sensor and mechanical faults, which were then validated by comparing their effects on system performance to expected symptoms. We summarize the nature of each fault and their impacts under different weather and operation conditions. Finally, we highlight considerations for FDD developers that may want to use this dataset to assess their algorithms’ performance and their improvement over time.

Casillas, Armando↗

Final Technical Report: PV Fault Detection Tool.

The PV Fault Detection Tool project plans to demonstrate that the FDT can (a) detect catastrophic and degradation faults and (b) identify the type of fault. This will be accomplished by collecting fault signatures using different instruments and integrating this information to establish a logical controller for detecting, diagnosing and classifying each fault.

42 ENGINEERING↗

Determining the Impact of Steady-State PV Fault Current Injections on Distribution Protection

This report investigates the fault current contribution from a single large PV system and the impact it has on existing distribution overcurrent protection devices. Assumptions are made about the modeling of the PV system under fault to perform exhaustive steady - state fault analyses throughout distribution feeder models. Each PV interconnection location is tested to determine how the size of the PV system affects the fault current measured by each protection device. This data is then searched for logical conditions that indicate whether a protection device has operated in a manner that will cause more customer outages due to the addition of the PV system. This is referred to as a protection issue , and there are four unique types of issues that have been identified in the study. The PV system size at which any issues occur are recorded to determine the feeder's PV hosting capacity limitations due to interference with protection settings. The analysis is carried out on six feeder models. The report concludes with a discussion of the prevalence and cause of each protection issue caused by PV system fault current.

30 DIRECT ENERGY CONVERSION↗

Fault Analysis and Detection in Microgrids with High PV Penetration

In this report we focus on analyzing current-controlled PV inverters behaviour under faults in order to develop fault detection schemes for microgrids with high PV penetration. Inverter model suitable for steady state fault studies is presented and the impact of PV inverters on two protection elements is analyzed. The studied protection elements are superimposed quantities based directional element and negative sequence directional element. Additionally, several non-overcurrent fault detection schemes are discussed in this report for microgrids with high PV penetration. A detailed time-domain simulation study is presented to assess the performance of the presented fault detection schemes under different microgrid modes of operation.

30 DIRECT ENERGY CONVERSION↗

Rupture Dynamics Simulations of Shallow Crustal Earthquakes on Reverse Slip Faults

The main goal of this study was to perform dynamic rupture simulations in order constrain the characterization of kinematic rupture models implemented in techniques for simulating strong ground motion for crustal earthquakes. First, we investigated the rupture process of the 2008 Iwate-Miyagi Nairiku earthquake by developing a dynamic rupture model on a reverse fault using a trial-and-error technique that produced a slip distribution and near-fault ground motion that matched the recorded ones. The simulations were performed in the frequency range 0-2 Hz, using a 3D staggered grid finite-difference method and a linear slip weakening friction law. Constrained by the observed slip distribution and consistent with dynamic rupture models, the derived kinematic rupture model of the Iwate-Miyagi Nairiku earthquake contains areas with relatively large slip rate, representing strong motion generation areas, set against lower amplitude heterogeneous background slip, and a relatively low slip rate in the weak zone of the top-most crust (upper 3km). Second, we performed rupture dynamics modeling to constrain shallow slip characterization in rupture models for strike-slip crustal earthquakes. The objective was to establish general rules about the characterization of slip rate function and slip at shallow depths and in the strong motion generation areas (SMGAs). The simulations of spontaneous rupture were performed in the frequency range 0-2.0Hz, using a 3D staggered-grid finite-difference method and a layer over half-space 1D crustal velocity model with a minimum shear-wave velocity of 2.8 km/s. In order to account for changes in material ductility and reduction of stress drop, observed in the shallow crust (upper 3-5 km), and the transition from ductile state to brittle state in the upper seismogenic zone, in our stress models we included a shallow weak zone (<4km). In this zone the stress drop was set to zero at the free surface and gradually increased with depth, while the slip weakening distance was set to 75 cm at the free surface and decreased to 50 cm at the base of the weak zone. As in the case of reverse faulting during the Iwate-Miyagi Nairiku earthquake, from these computations we found a systematic change in the shape of the slip-rate function, from Kostrov-type in the deeper part of the fault to a more symmetric cosine-type in the upper few kilometers, near the free-surface. Moreover, the average slip duration in the weak zone, with respect to slip duration in the deeper parts of the fault, increases by at most a factor of 1.5. We found a systematic and gradual change in the shape of the slip-rate function from Kostrov-type in the asperity areas (SMGAs), to more symmetric cosine-type in the upper few km near the free-surface, on the long period motion generation area (LMGA). The effective rise time in the LMGA, with respect to that in the SMGAs, increases by at most a factor of 2. Effective rise time is the time difference between the time at which the slip rate drops to a level that is equal to 25% of its peak and the onset time of the signal. In addition, the slip in the LMGA located above the SMGAs is almost the same as the one in the SMGAs, and about 1.5 times larger than the average slip.

58 GEOSCIENCES↗

Machine Learning Based Cavity Fault Classification and Prediction

We report on the development of machine learning models for classifying C100 superconducting radio frequency (SRF) cavity faults in the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab. CEBAF is a continuous-wave recirculating linac utilizing 418 SRF cavities to accelerate electrons up to 12 GeV through 5-passes. Of these, 96 cavities (12 cryomodules) are designed with a digital low-level RF system configured such that a cavity fault triggers waveform recordings of 17 RF signals for each of the eight cavities in the cryomodule. Subject matter experts (SME) can analyze the collected time-series data, identify which of the eight cavities faulted first, and classify the type of fault. This information is used to find trends and strategically deploy mitigations to problematic cryomodules. However, manually labeling the data is laborious and time-consuming. By leveraging machine learning, near real-time – rather than post-mortem – identification of the offending cavity and classification of the fault type has been implemented. We discuss the performance of the ML models during a recent physics run.

43 PARTICLE ACCELERATORS↗

Blockchain for Fault-Tolerant Grid Operations

Distribution system fault/failure has a direct impact on customers. Distribution systems are not designed with the contingency of one or more elements failing as the transmission system, however, distribution systems are more likely to have faults in comparison to transmission and generation systems. Most of the distribution systems have a radial design with the protection system assumption of unidirectional power flow. The radial design results in the disconnection of customers for any given component failure. The rapid deployment of distributed energy resources conflicts with the assumption of unidirectional power flow. To maintain/improve the distribution system fault tolerance for a grid with high penetration of distributed energy resources requires improvement. Blockchain can add value to improve fault-tolerant grid operations. That can be achieved using blockchain’s core features of distributed consensus-based decision-making process and immutability. In the process of preparing for an event or system restoration, there is a need for reliable data and system situational awareness. The system situational awareness enables accurate planning for possible scenarios and system restoration after an event, an area where blockchain’s distributed architecture can help. The value of blockchain for a fault-tolerant grid operation is elaborated with three use cases: 1) fault location, isolation, and service restoration; 2) topology identification; and 3) data configuration. These use cases demonstrate how blockchain-based architecture can facilitate bridging the vulnerabilities of the existing implementation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Activating a Natural Fault Zone in the Swiss Alps

One major hurdle for understanding earthquake mechanics are observational limitations. Important phenomena like strain localisation, fault dilation, and fault healing are readily studied in rock mechanical laboratory experiments and with numerical models. At the scale of natural earthquakes, however, these phenomena are often unresolvable, even by state-of-the-art observatories. To overcome this limitation, we are currently building the Earthquake Physics Testbed at the Bedretto Underground Laboratory for Geosciences and Geoenergies (BedrettoLab), an experimental testbed where we can activate an extensively instrumented natural fault zone via hydraulic stimulation. The goal of the Fault Activation and Earthquake Rupture (FEAR) project is to induce earthquakes of up to Mw~1.0 on this exceptionally well characterised and instrumented fault zone. Here we summarize the main scientific goals and current FEAR project status, and present first results from conducted experiments. We discuss how this large-scale experimental approach may allow us to tackle both fundamental science as well as practical questions on earthquake physics, induced seismicity and seismic hazard.

Meier, Men-Andrin↗

A Systematic Framework for Tuning Open-Source Multifunctional IBR Models To Emulate OEM Black-Box Fault Dynamics

This paper presents a systematic framework to tune a generic IBR EMT model to match with an OEM provided balckbox inverter model based on the fault current responses. The key learnings and findings are summarized as follows: The tunable key parameters include inner control loops and current limiters to align the fault current magnitude, sequence content, and phase trajectories with the OEM models across diverse fault type and locations. The tuned model's fidelity is validated through comparative analysis with an OEM blackbox model, assessing both the fault current response and the responses of multiple relay elements. The results demonstrate the tuned generic model can trigger relay decision logic that is identical or near identical to that of the OEM model, thus generating very good match model for fault studies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Locatability of faults in combinational networks.

A formal model for the study of reliable combinational networks is introduced and used to determine network properties conducive to the location of faults. The usual concept of fault location is generalized to be an interval on the partially ordered set of subsets of network nodes that classifies nodes into three disjoint sets: a faulty set, a fault-free set, and an indeterminate set. After developing basic properties of locatable faults, necessary and sufficient conditions for a fault to be locatable in an arbitrary network are stated and proven.

Gray, F. G.↗

Sequential behavior and its inherent tolerance to memory faults.

Representation of a memory fault of a sequential machine M by a function mu on the states of M and the result of the fault by an appropriately determined machine M(mu). Given some sequential behavior B, its inherent tolerance to memory faults can then be measured in terms of the minimum memory redundancy required to realize B with a state-assigned machine having fault tolerance type tau and fault tolerance level t. A behavior having maximum inherent tolerance is exhibited, and it is shown that behaviors of the same size can have different inherent tolerance.

Meyer, J. F.↗

Evaluation of feasibility of mapping seismically active faults in Alaska

The author has identified the following significant results. A previously unmapped seismically active fault has been identified in south-central Alaska on the basis of ERTS-1 imagery. It can be traced for at least 120 km. An unmapped fault was found on the northwest flank of Mt. Sanford that is apparently a reverse fault. A large scale, seismically active fracture system has been identified in central Alaska on the basis of MSS imagery. The system consists of two sets of fractures which intersect at an angle of about 55 degrees. The dominant feature of the system is the Minook Creek fault, on which an earthquake of magnitude 6.5 occurred on October 29, 1968. A possible related feature is a 60 km long lineament near the Toklat River north of Mt. McKinley. These areas are all moderately seismically active. Focal mechanism studies of the 1968 earthquake revealed that left-lateral displacement had occurred on the Minook Creek fault due to compressive stress. A similarly oriented direction of compressive stress could be responsible for the entire fracture system.

Gedney, L. D.↗

System applications of the fault tolerant memory

Conventional memory technologies currently employed in aerospace applications contribute at least fifty percent to system unreliability (where the system includes CPU, I/O and memory). A fault tolerant memory performs both error correction and memory replacement at the bit plane level. To determine the effects of system design of using a fault tolerant memory in space applications, analysis was performed to determine tradeable hardware configurations that meet the reliability goals of each program. The candidate configurations, which included redundant elements of the computer system with both conventional and fault tolerant memories, were then traded in terms of selection criteria of cost, weight, volume, and power. These trade studies demonstrated that a fault tolerant memory provided significant advantages in terms of cost, weight, and volume. The memory selected for this analysis was a recently developed five fault tolerant memory.

Murphy, L. J.↗

Implementation of an experimental fault-tolerant memory system

The experimental fault-tolerant memory system described in this paper has been designed to enable the modular addition of spares, to validate the theoretical fault-secure and self-testing properties of the translator/corrector, to provide a basis for experiments using the new testing and correction processes for recovery, and to determine the practicality of such systems. The hardware design and implementation are described, together with methods of fault insertion. The hardware/software interface, including a restricted single error correction/double error detection (SEC/DED) code, is specified. Procedures are carefully described which, (1) test for specified physical faults, (2) ensure that single error corrections are not miscorrections due to triple faults, and (3) enable recovery from double errors.

Carter, W. C.↗

Fault-tolerant building-block computer study

Ultra-reliable core computers are required for improving the reliability of complex military systems. Such computers can provide reliable fault diagnosis, failure circumvention, and, in some cases serve as an automated repairman for their host systems. A small set of building-block circuits which can be implemented as single very large integration devices, and which can be used with off-the-shelf microprocessors and memories to build self checking computer modules (SCCM) is described. Each SCCM is a microcomputer which is capable of detecting its own faults during normal operation and is described to communicate with other identical modules over one or more Mil Standard 1553A buses. Several SCCMs can be connected into a network with backup spares to provide fault-tolerant operation, i.e. automated recovery from faults. Alternative fault-tolerant SCCM configurations are discussed along with the cost and reliability associated with their implementation.

Rennels, D. A.↗