At least 721 records · Page 40

Comparison Of Electromagnetic, Electrostatic And Permanent Magnet Quadrupole Lens Probe-Forming Systems For High Energy Ions

The focusing system is an essential part of any ion microbeam system and focusing of MeV ion beams is generally accomplished using quadrupole lenses. There are two types of quadrupole lenses requiring the application of either voltage or current to provide the excitation, but there is also the possibility of utilizing lenses constructed from permanent magnets. All of these lens types have different advantages and disadvantages. Most microprobes employ electromagnetic quadrupoles for focusing, however electrostatic lenses have several advantages with respect to electromagnetic lenses, including significantly smaller size, no hysteresis effects, no heating, the utilization of highly stable voltage supplies, focusing which is independent of ion mass, and construction from industrial grade materials. The main advantage of the permanent magnetic lens is that it does not require the application of external power which can significantly reduce the overall lifetime cost. In this presentation, the short probe-forming systems comprised from all these types of quadrupole lenses are compared and the smallest beam spot size and appropriate optimal parameters of these probe-forming systems are determined.

43 PARTICLE ACCELERATORS↗

Electron holographic tomography for mapping the three-dimensional distribution of electrostatic potential in III-V semiconductor nanowires

Electron holographic tomography (EHT), the combination of off-axis electron holography with electron tomography, is a technique, which can be applied to the quantitative 3-dimensional (3D) mapping of electrostatic potential at the nanoscale. Here, we show the results obtained in the EHT investigation of GaAs and GaAs-AlGaAs core-shell nanowires grown by Au-catalysed metalorganic vapor phase epitaxy. The unique ability of EHT of disentangling the materials mean inner potential (MIP) from the specimen projected thickness allows reconstruction of the nanowire 3D morphology and inner compositional structure as well as the measurement of the MIP.

43 PARTICLE ACCELERATORS↗

The KACST Heavy-Ion Electrostatic Storage Ring

A novel Electrostatic Storage Ring (ESR) for beams at energies up to 30keV/q is now being constructed at the National Centre for Mathematics and Physics (NCMP), King Abdul-Aziz City for Science and Technology (KACST). The ring is designed to be the core of a highly flexible experimental platform that will combine a large package of complementary beam techniques for atomic and molecular physics and related fields. The lattice design had to cover the different experimental techniques that the ring will be equipped with, such as e.g. Electron-Ion, Laser-Ion, Ion-Ion or Ion-Neutral beams, in both crossed and merged-beam configurations. The development of such an ESR is realized in a staged approach, in which a simple and early-run adaptation of the ring is built first, and then this basic version is upgraded to a higher symmetry of the ultimate version of the ring. Here, we report a general overview of this technical development with a focus on the layout of the first built stage of the ring.

43 PARTICLE ACCELERATORS↗

Numerical simulation of gridded electrostatic lens

Gridded electrostatic lenses are frequently used in extraction systems and low energy ion beam transport line. Typically, for numerical simulation the grid is treated as a metal plate transparent for beam particles. The influence of real grid geometry on the beam dynamics in the gridded lens has been investigated by KOBRA-3d code. Beam emittance growth for different lens parameters has been investigated. Approximating expressions for obtained results are presented. The grid geometry providing minimal beam distortions is proposed.

43 PARTICLE ACCELERATORS↗

Electrostatic plasma lens for focusing negatively charged particle beams

We describe the current status of ongoing research and development of the electrostatic plasma lens for focusing and manipulating intense negatively charged particle beams, electrons, and negative ions. The physical principle of this kind of plasma lens is based on magnetic isolation electrons providing creation of a dynamical positive space charge cloud in shortly restricted volume propagating beam. Here, the new results of experimental investigations and computer simulations of wide-aperture, intense electron beam focusing by plasma lens with positive space charge cloud produced due to the cylindrical anode layer accelerator creating a positive ion stream towards an axis system is presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The geometric factor of electrostatic plasma analyzers: A case study from the Fast Plasma Investigation for the Magnetospheric Multiscale mission

We report our findings comparing the geometric factor (GF) as determined from simulations and laboratory measurements of the new Dual Electron Spectrometer (DES) being developed at NASA Goddard Space Flight Center as part of the Fast Plasma Investigation on NASA's Magnetospheric Multiscale mission. Particle simulations are increasingly playing an essential role in the design and calibration of electrostatic analyzers, facilitating the identification and mitigation of the many sources of systematic error present in laboratory calibration. While equations for laboratory measurement of the GF have been described in the literature, these are not directly applicable to simulation since the two are carried out under substantially different assumptions and conditions, making direct comparison very challenging. Starting from first principles, we derive generalized expressions for the determination of the GF in simulation and laboratory, and discuss how we have estimated errors in both cases. Finally, we apply these equations to the new DES instrument and show that the results agree within errors. Thus we show that the techniques presented here will produce consistent results between laboratory and simulation, and present the first description of the performance of the new DES instrument in the literature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lifetime measurements in an electrostatic ion beam trap using image charge monitoring

A technique for mass-selective lifetime measurements of keV ions in a linear electrostatic ion beam trap is presented. The technique is based on bunching the ions using a weak RF potential and non-destructive ion detection by a pick-up electrode. This method has no mass-limitation, possesses the advantage of inherent mass-selectivity, and offers a possibility of measuring simultaneously the lifetimes of different ion species with no need for prior mass-selection.

43 PARTICLE ACCELERATORS↗

Upgrade of the MIT Linear Electrostatic Ion Accelerator (LEIA) for nuclear diagnostics development for Omega, Z and the NIF

The MIT Linear Electrostatic Ion Accelerator (LEIA) generates DD and D{sup 3}He fusion products for the development of nuclear diagnostics for Omega, Z, and the National Ignition Facility (NIF). Significant improvements to the system in recent years are presented. Fusion reaction rates, as high as 10{sup 7} s{sup -1} and 10{sup 6} s{sup -1} for DD and D{sup 3}He, respectively, are now well regulated with a new ion source and electronic gas control system. Charged fusion products are more accurately characterized, which allows for better calibration of existing nuclear diagnostics. In addition, in situ measurements of the on-target beam profile, made with a CCD camera, are used to determine the metrology of the fusion-product source for particle-counting applications. Finally, neutron diagnostics development has been facilitated by detailed Monte Carlo N-Particle Transport (MCNP) modeling of neutrons in the accelerator target chamber, which is used to correct for scattering within the system. These recent improvements have resulted in a versatile platform, which continues to support the existing nuclear diagnostics while simultaneously facilitating the development of new diagnostics in aid of the National Ignition Campaign at the National Ignition Facility.

43 PARTICLE ACCELERATORS↗

Invited Review Article: The electrostatic plasma lens

The fundamental principles, experimental results, and potential applications of the electrostatic plasma lens for focusing and manipulating high-current, energetic, heavy ion beams are reviewed. First described almost 50 years ago, this optical beam device provides space charge neutralization of the ion beam within the lens volume, and thus provides an effective and unique tool for focusing high current beams where a high degree of neutralization is essential to prevent beam blow-up. Short and long lenses have been explored, and a lens in which the magnetic field is provided by rare-earth permanent magnets has been demonstrated. Applications include the use of this kind of optical tool for laboratory ion beam manipulation, high dose ion implantation, heavy ion accelerator injection, in heavy ion fusion, and other high technology.

43 PARTICLE ACCELERATORS↗

DropBot: An open-source digital microfluidic control system with precise control of electrostatic driving force and instantaneous drop velocity measurement

We introduce DropBot: an open-source instrument for digital microfluidics (http://microfluidics.utoronto.ca/dropbot). DropBot features two key functionalities for digital microfluidics: (1) real-time monitoring of instantaneous drop velocity (which we propose is a proxy for resistive forces), and (2) application of constant electrostatic driving forces through compensation for amplifier-loading and device capacitance. We anticipate that this system will enhance insight into failure modes and lead to new strategies for improved device reliability, and will be useful for the growing number of users who are adopting digital microfluidics for automated, miniaturized laboratory operation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Potential structure of discharge plasma inside liquid directly measured by an electrostatic probe

Potential structures of a discharge plasma inside a liquid are investigated by an electrostatic probe measurement. The time evolution of radial profiles of the floating potential for the plasma inside liquid reveals that the dominant negative charges in the plasma are the negative ion species such as OH{sup -} and O{sub 2}{sup -} rather than electrons. In addition, a positive potential gradient exists at the plasma-liquid interface due to the presence of an electrical double layer which is caused by the separation of low-mass positive ion of H{sup +} and high-mass negative ions of OH{sup -} and O{sub 2}{sup -} near the plasma-liquid interface.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electrostatics of proteins in dielectric solvent continua. I. An accurate and efficient reaction field description

We present a reaction field (RF) method which accurately solves the Poisson equation for proteins embedded in dielectric solvent continua at a computational effort comparable to that of an electrostatics calculation with polarizable molecular mechanics (MM) force fields. The method combines an approach originally suggested by Egwolf and Tavan [J. Chem. Phys. 118, 2039 (2003)] with concepts generalizing the Born solution [Z. Phys. 1, 45 (1920)] for a solvated ion. First, we derive an exact representation according to which the sources of the RF potential and energy are inducible atomic anti-polarization densities and atomic shielding charge distributions. Modeling these atomic densities by Gaussians leads to an approximate representation. Here, the strengths of the Gaussian shielding charge distributions are directly given in terms of the static partial charges as defined, e.g., by standard MM force fields for the various atom types, whereas the strengths of the Gaussian anti-polarization densities are calculated by a self-consistency iteration. The atomic volumes are also described by Gaussians. To account for covalently overlapping atoms, their effective volumes are calculated by another self-consistency procedure, which guarantees that the dielectric function ε(r) is close to one everywhere inside the protein. The Gaussian widths σ{sub i} of the atoms i are parameters of the RF approximation. The remarkable accuracy of the method is demonstrated by comparison with Kirkwood's analytical solution for a spherical protein [J. Chem. Phys. 2, 351 (1934)] and with computationally expensive grid-based numerical solutions for simple model systems in dielectric continua including a di-peptide (Ac-Ala-NHMe) as modeled by a standard MM force field. The latter example shows how weakly the RF conformational free energy landscape depends on the parameters σ{sub i}. A summarizing discussion highlights the achievements of the new theory and of its approximate solution particularly by comparison with so-called generalized Born methods. A follow-up paper describes how the method enables Hamiltonian, efficient, and accurate MM molecular dynamics simulations of proteins in dielectric solvent continua.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Atomic resolution electrostatic potential mapping of graphene sheets by off-axis electron holography

Off-axis electron holography has been performed at atomic resolution with the microscope operated at 80 kV to provide electrostatic potential maps from single, double, and triple layer graphene. These electron holograms have been reconstructed in order to obtain information about atomically resolved and mean inner potentials. We propose that off-axis electron holography can now be used to measure the electrical properties in a range of two-dimensional semiconductor materials and three dimensional devices comprising stacked layers of films to provide important information about their electrical properties.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Automated electrostatic probe device of high resolution and accuracy

In this work, an automated apparatus for driving single electrostatic probes and acquiring the plasma-related data has been designed and fabricated. The voltage range of the present system is ±110 V with an adjustable voltage step as low as 3 mV. Voltage and current measurements are carried out with high resolution and high accuracy circuits, both based on 16 bit analog-to-digital converters. The code embedded in a micro-controller, schedules the operation of the device and transfers the experimental data to a personal computer. The modular design of the system makes possible its modification and thus increases its adaptability to different plasma setups. Finally, the reliable operation of the entire device is confirmed by tests in Electron Cyclotron Resonance plasma.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On the response of large systems to electrostatic fields

By modifying the surfaces of a macroscopic regular system it is possible to modify the dipole moment per unit by an amount equal to a lattice vector times the elementary charge. Alternatively, we may ignore the surfaces and treat the system as being infinite and periodic. In that event the dipole moment per unit is determined only up to an additive term equal to a lattice vector times the elementary charge. Beyond mathematical arguments we show, through model calculations, that the two cases are completely equivalent, even though the origin of the additive term is very different. The response of extended systems to electrostatic fields — including internal structure, piezoelectricity, bulk charge density, and (hyper)polarizabilities — depends upon this term and is, thereby, surface-dependent. The case of piezoelectricity is analyzed in some detail.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dispersion of Co/CNTs via strong electrostatic adsorption method: Thermal treatment effect

The effect of different thermal treatment temperature on the structure of multi-walled carbon nanotubes (MWCNTs) and Co particle dispersion on CNTs support is studied using Strong electrostatic adsorption (SEA) method. The samples tested by N{sub 2}-adsorption, field emission scanning electron microscopy (FE-SEM) and transmission electron microscopy (TEM). N{sub 2}-adsorption results showed BET surface area increased using thermal treatment and TEM images showed that increasing the thermal treatment temperature lead to flaky CNTs and defects introduced on the outer surface and Co particle dispersion increased.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Preliminary design of electrostatic sensors for MITICA beam line components

Megavolt ITER Injector and Concept Advancement, the full-scale prototype of ITER neutral beam injector, is under construction in Italy. The device will generate deuterium negative ions, then accelerated and neutralized. The emerging beam, after removal of residual ions, will be dumped onto a calorimeter. The presence of plasma and its parameters will be monitored in the components of the beam-line, by means of specific electrostatic probes. Double probes, with the possibility to be configured as Langmuir probes and provide local ion density and electron temperature measurements, will be employed in the neutralizer and in the residual ion dump. Biased electrodes collecting secondary emission electrons will be installed in the calorimeter with the aim to provide a horizontal profile of the beam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electrostatic analysis of n-doped SrTiO{sub 3} metal-insulator-semiconductor systems

Electron doped SrTiO{sub 3}, a complex-oxide semiconductor, possesses novel electronic properties due to its strong temperature and electric-field dependent permittivity. Due to the high permittivity, metal/n-SrTiO{sub 3} systems show reasonably strong rectification even when SrTiO{sub 3} is degenerately doped. Our experiments show that the insertion of a sub nanometer layer of AlO{sub x} in between the metal and n-SrTiO{sub 3} interface leads to a dramatic reduction of the Schottky barrier height (from around 0.90 V to 0.25 V). This reduces the interface resistivity by 4 orders of magnitude. The derived electrostatic analysis of the metal-insulator-semiconductor (n-SrTiO{sub 3}) system is consistent with this trend. When compared with a Si based MIS system, the change is much larger and mainly governed by the high permittivity of SrTiO{sub 3}. The non-linear permittivity of n-SrTiO{sub 3} leads to unconventional properties such as a temperature dependent surface potential non-existent for semiconductors with linear permittivity such as Si. This allows tuning of the interfacial band alignment, and consequently the Schottky barrier height, in a much more drastic way than in conventional semiconductors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗