Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Far infrared heterodyne systems

Three far infrared detectors, the InSb hot electron bolometer, the GaAs Schottky diode and the Josephson point contact junction, were incorporated as mixers into sensitive heterodyne systems. The performances of existing heterodyne receivers/radiometers using these detectors are described and compared. Other applications of submillimeter heterodyne techniques are discussed.

Tannenwald, P. E.↗

Test results from LAGEOS-2 optical characterization using pulsed lasers

The Laser Geodynamic Satellite-2 (LAGEOS-2) has undergone extensive optical testing at NASA Goddard Space Flight Center during 1989. The techniques included measuring the far field diffraction pattern using cw and pulsed lasers. In the pulsed measurement technique, response of the satellite was studied by measuring the far-field diffraction pattern (FFDP) as a function of pulsewidth, wavelength, polarization, position in the FFDP, detector/processing techniques, and satellite orientation. The purpose of the pulsed laser testing was two-fold: (1) to characterize the satellite optical response with the detector and signal processing electronics currently used in most SLR stations using the portable laser ranging standard, and (2) to characterize the satellite response for various conditions using the highest bandwidth optical detector (streak camera) available for the next generation of satellite laser ranging (SLR) technology. The portable ranging standard employed multiple measurement devices and an optical calibration scheme to eliminate range-dependent and amplitude-dependent systematics. These precautions were taken to eliminate/minimize instrumental errors and provide maximum accuracy. For LAGEOS orbit (6000 Km), ground stations are located 34 to 38 Mu radians off the axis of the return signal from the satellite; therefore, an optical mask was used to restrict the field of view (FOV) of detection to this annular region of the FFDP. The two measurement techniques were implemented using an aperture sharing scheme and complemented each other by providing mutual verification.

Varghese, Thomas K.↗

Cosmic Ray Energetics and Mass (CREAM)

The CREAM instrument was flown on a Long Duration Balloon in Antarctica in December 2004 and January 2005, achieving a flight duration record of nearly 42 days. It detected and recorded cosmic ray primary particles ranging in type from hydrogen to iron nuclei and in energy from 1 TeV to several hundred TeV. With the data collected we will have the world's best measurement of the energy spectra and mass composition of nuclei in the primary cosmic ray flux at these energies, close to the astrophysical knee . The instrument utilized a thin calorimeter, a transition radiation detector and a timing charge detector, which also provided time-of-flight information. The responsibilities of our group have been with the timing charge detector (TCD), and with the data acquisition electronics and ground station support equipment. The TCD utilized fast scintillators to measure the charge of the primary cosmic ray before any interactions could take place within the calorimeter. The data acquisition electronics handled the output of the various detectors, in a fashion fully integrated with the payload bus. A space-qualified flight computer controlled the acquisition, and was used for preliminary trigger information processing and decision making. Ground support equipment was used to monitor the health of the payload, acquire and archive the data transmitted to the ground, and to provide real-time control of the instrument in flight.

Coutu, Stephane↗

Self-scanned anode array with a microchannel plate electron multiplier - The SSANACON

A photoelectron counting detector utilizing a 128-element linear self-scanned anode array to collect the output of a dual microchannel plate electron multiplier is described. The operation of the detector, its spatial resolution and detection efficiency, and radiation behavior are discussed. The low-noise detector was developed for the Mariner Jupiter/Saturn mission UV spectrometer, and offers a large dynamic range and count rate of 0.003 per anode-sec. It can measure simultaneously two spatially separated signals differing by more than six orders of magnitude in count rate.

Broadfoot, A. L.↗

A large area 100-channel PICOSEC Micromegas detector with time resolution at the 20 ps level

Abstract The PICOSEC Micromegas precise timing detector is based on a Cherenkov radiator coupled to a photocathode operating in a semi-transparent mode and a Micromegas amplification structure. The first proof of concept single-channel prototype was able to achieve a time resolution below 25 ps. One of the crucial aspects in the development of precise timing gaseous detectors applicable in high-energy physics experiments is a modular design that enables large area coverage. The first 19-channel multi-pad prototype with an active area of approximately 10 cm 2 suffered from degraded timing resolution due to the non-uniformity of the preamplification gap thickness. A new 100 cm 2 detector module with 100 channels based on a rigid hybrid ceramic/FR4 Micromegas board for improved drift gap uniformity was developed. Initial measurements with 80 GeV/c muons showed improvements in timing response over the measured pads and a time resolution below 25 ps. More recent measurements with a thinner drift gap detector module and newly developed RF pulse amplifiers show that the pad centre resolution can be enhanced to the level of 17 ps. This work will present the development of the detector from structural simulations, design, and beam test commissioning with a focus on the timing performance of a thinner drift gap detector module in combination with new electronics using an automated timing scan method.

Utrobicic, A.↗

Measurement of Electron-Neutrino Charged-Current Cross Sections on 127 I with the COHERENT NaI$ν$E Detector

Using an 185-kg NaI[Tl] array, COHERENT has measured the inclusive electron-neutrino chargedcurrent cross section on 127 I with pion decay-at-rest neutrinos produced by the Spallation Neutron Source at Oak Ridge National Laboratory. Iodine is one the heaviest targets for which low-energy (≤ 50 MeV) inelastic neutrino-nucleus processes have been measured, and this is the first measurement of its inclusive cross section. After a five-year detector exposure, COHERENT reports a flux-averaged cross section for electron neutrinos of ${9.2}_{–1.8}^{+2.1}$ × 10 –40 cm 2 . This corresponds to a value that is ~41% lower than predicted using the MARLEY event generator with a measured Gamow-Teller strength distribution. In addition, the observed visible spectrum from charged-current scattering on 127 I has been measured between 10 and 55 MeV, and the exclusive zero-neutron and one-or-more-neutron emission cross sections are measured to be ${5.2}_{–3.1}^{+3.4}$ × 10 –40 and ${2.2}_{—2.2}^{+3.5}$ × 10 –40 cm 2 , respectively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Remote sensing using solid-state array technology

The paper describes the design features and capabilities of a remote sensor that uses solid-state linear arrays and operates in a 'pushbroom' scan mode to provide the required performance. Pushbroom scanning is a term describing the technique of using the forward motion of a satellite platform to sweep a linear array of detectors oriented perpendicular to the ground track across a scene being imaged. One array is typically used for each spectral channel. Satellite motion provides one direction of scan and electronic sampling of the detectors in the crosstrack dimension provides the orthogonal scan component to form an image. The detector array is sampled at the appropriate rate so that contiguous lines are produced. The performance of a pushbroom system is discussed relative to radiometric sensitivity, detector array geometric fidelity, and radiometric correction. System advantages are precision geometric positioning of the detectors, very high sensitivity and favorable SNR, low power consumption, and no moving optics.

Thompson, L. L.↗

The New Small Wheel electronics

The increase in luminosity, and consequent higher backgrounds, of the LHC upgrades require improved rejection of fake tracks in the forward region of the ATLAS Muon Spectrometer. The New Small Wheel upgrade of the Muon Spectrometer aims to reduce the large background of fake triggers from track segments that don't originate from the interaction point. The New Small Wheel employs two detector technologies, the resistive strip Micromegas detectors and the “small” Thin Gap Chambers, with a total of 2.45 million electrodes to be sensed. The two technologies require the design of a complex electronics system given that it consists of two different detector technologies and is required to provide both precision readout and a fast trigger. It will operate in a high background radiation region up to about 20 kHz/cm 2 at the expected HL-LHC luminosity of $\mathcal{L}$= 7.5 × 10 34 cm -2 s -1 . The architecture of the system is strongly defined by the GBTx data aggregation ASIC, the newly-introduced FELIX data router and the software based data handler of the ATLAS detector. The electronics complex of this new detector was designed and developed in the last ten years and consists of multiple radiation tolerant Application Specific Integrated Circuits, multiple front-end boards, dense boards with FPGA's and purpose-built Trigger Processor boards within the ATCA standard. The New Small Wheel has been installed in 2021 and is undergoing integration within ATLAS for LHC Run 3. It should operate through the end of Run 4 (December 2032). In this manuscript, the overall design of the New Small Wheel electronics is presented.

47 OTHER INSTRUMENTATION↗

Comparative evaluation of analogue front-end designs for the CMS Inner Tracker at the High Luminosity LHC

The CMS Inner Tracker, made of silicon pixel modules, will be entirely replaced prior to the start of the High Luminosity LHC period. One of the crucial components of the new Inner Tracker system is the readout chip, being developed by the RD53 Collaboration, and in particular its analogue front-end, which receives the signal from the sensor and digitizes it. Three different analogue front-ends (Synchronous, Linear, and Differential) were designed and implemented in the RD53A demonstrator chip. A dedicated evaluation program was carried out to select the most suitable design to build a radiation tolerant pixel detector able to sustain high particle rates with high efficiency and a small fraction of spurious pixel hits. The test results showed that all three analogue front-ends presented strong points, but also limitations. The Differential front-end demonstrated very low noise, but the threshold tuning became problematic after irradiation. Moreover, a saturation in the preamplifier feedback loop affected the return of the signal to baseline and thus increased the dead time. The Synchronous front-end showed very good timing performance, but also higher noise. For the Linear front-end all of the parameters were within specification, although this design had the largest time walk. This limitation was addressed and mitigated in an improved design. The analysis of the advantages and disadvantages of the three front-ends in the context of the CMS Inner Tracker operation requirements led to the selection of the improved design Linear front-end for integration in the final CMS readout chip.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements on the shuttle of the LET spectra of galactic cosmic radiation and comparison with the radiation transport model

A new class of tissue-equivalent proportional counters has been flown on two space shuttle flights. These detectors and their associated electronics cover a lineal energy range from 0.4 to 1250 keV/microns with a multichannel analyzer resolution of 0.1 keV/microns from 0.4 to 20 keV/microns and 5 keV/microns from 20 to 1250 keV/microns. These detectors provide the most complete dynamic range and highest resolution of any technique currently in use. On one mission, one detector was mounted in the Shuttle payload bay and another older model in the mid-deck, thus providing information on the depth dependence of the lineal energy spectrum. A detailed comparison of the observed lineal energy and calculated LET spectra for galactic cosmic radiation shows that, although the radiation transport models provide a rather accurate description of the dose (+/- 15%) and equivalent dose (+/- 15%), the calculations significantly underestimate the frequency of events below about 100 keV/microns. This difference cannot be explained by the inclusion of the contribution of splash protons. The contribution of the secondary pions, kaons and electrons produced in the Shuttle shielding, if included in the radiation transport model, may explain these differences. There are also significant differences between the model predictions and observations above 140 keV/microns, particularly for 28.5 degrees inclination orbit.

NASA Discipline Radiation Health↗

Energetic radiations from solar flares

An experiment designed to measure energetic X-rays, electrons, protons and alpha particles from solar flares aboard OGO 5 is reported. A brief statement of the objectives of the experiment is followed by a description of the instrumentation including detector characteristics and associated electronics. The data handling system is then described and the operational history of the experiment is discussed. This is followed by a description of the format of the magnetic data tapes and a summary of the major computer processing programs. The measurements made with this experiment within the first year of its operation have led to several basic results regarding the role of non-thermal electrons in the physics of solar flares. These results are described in the papers listed in the bibliography given at the end of this report.

Anderson, K. A.↗

Comparative Observations of the Outer Belt Electron Fluxes and Precipitated Relativistic Electrons

Relativistic electron precipitation (REP) refers to the release of high‐energy electrons initially trapped in the outer radiation belt, which then precipitate into Earth's upper atmosphere, contributing significantly to the rapid depletion of radiation belt electron flux. This study presents a statistical analysis of REP observations collected by the Calorimetric Electron Telescope (CALET) experiment aboard the International Space Station from 2015 to the present day. Specifically, the analysis utilizes count rates acquired from the two top scintillators constituting the top charge detector, each sensitive to electrons with energies above 1.5 and 3.4 MeV, respectively. Analysis of CALET data reveals a previously unreported semi‐annual variation in the occurrence of REP events. REP periodicities resemble those observed for trapped electron fluxes in the outer belt. Furthermore, their amplitude follows the overall trend of solar wind high‐speed streams and the solar activity.

Sergio E. Vidal-Luengo↗

Rad-hard readout system for Timepix3 Hybrid Pixel Detectors

The Beam Gas Ionisation (BGI) profile monitor, located in the Proton Synchrotron (PS) and Super Proton Synchrotron (SPS) at CERN, requires a radiation-tolerant readout system to transfer data from the challenging accelerator surroundings to the back-end for processing. The system needs to control and acquire data from four Timepix3 Hybrid Pixel Detectors (HPDs) located directly inside the beam pipe, a highly radioactive environment. It must ensure reliability given limited hardware access and preserve signal integrity for the high-speed data (32 channels at 320 MHz). However, due to the unavailability of a suitable rad-hard Timepix3 readout, the Beam Instrumentation PiXeL (BIPXL) readout system was designed to meet these requirements. This system employs radiation-hardened components such as the GBTx and the FEASTMP, both developed at CERN. It will be compatible with forthcoming hybrid pixel detector initiatives in similarly harsh radiation conditions.

47 OTHER INSTRUMENTATION↗

Progress Towards High-Sensitivity Arrays of Detectors of Sub-mm Radiation using Superconducting Tunnel Junctions with Radio-Frequency Single-Electron Transistors

The science drivers for the SPIRIT/SPECS missions demand sensitive, fast, compact, low-power, large-format detector arrays for high resolution imaging and spectroscopy in the far infrared and submillimeter. Detector arrays with 10,000 pixels and sensitivity less than 10(exp 20)-20 W/Hz(exp 20)0.5 are needed. Antenna-coupled superconducting tunnel junction detectors with integrated rf single-electron transistor readout amplifiers have the potential for achieving this high level of sensitivity, and can take advantage of an rf multiplexing technique when forming arrays. The device consists of an antenna structure to couple radiation into a small superconducting volume and cause quasiparticle excitations, and a single-electron transistor to measure currents through tunnel junction contacts to the absorber volume. We will describe optimization of device parameters, and recent results on fabrication techniques for producing devices with high yield for detector arrays. We will also present modeling of expected saturation power levels, antenna coupling, and rf multiplexing schemes.

Stevenson, T. R.↗

Electron tunnel sensor technology

The recent development of Scanning Tunneling Microscopy technology allows the application of electron tunneling to position detectors for the first time. The vacuum tunnel junction is one of the most sensitive position detection mechanisms available. It is also compact, simple, and requires little power. A prototype accelerometer based on electron tunneling, and other sensor applications of this promising new technology are described.

Waltman, S. B.↗

A proximity-focusing RICH detector for the ePIC Experiment at the EIC

The Electron-Proton/Ion Collider Experiment (ePIC) will be a large, multi-purpose detector to be installed at the Electron-Ion Collider (EIC) being built at Brookhaven National Laboratory. As robust particle identification (PID) capabilities are essential for fully realizing the EIC science program, ePIC contains several PID subsystems spanning different angular ranges. PID capability in the electron-going endcap is provided by a proximity-focusing Ring Imaging Cherenkov detector (pfRICH) designed to deliver at least 3σ separation between pions and kaons for momenta up to 7 GeV/ c . It will also aid with electron-hadron discrimination at low momentum and assist in the determination of the collision time (t 0 ). This contribution will summarize the design of the pfRICH as well as ongoing fabrication and component testing efforts. geant-based performance simulations will also be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nuclear Science Symposium, 31st and Symposium on Nuclear Power Systems, 16th, Orlando, FL, October 31-November 2, 1984, Proceedings

Topics related to physics instrumentation are discussed, taking into account cryostat and electronic development associated with multidetector spectrometer systems, the influence of materials and counting-rate effects on He-3 neutron spectrometry, a data acquisition system for time-resolved muscle experiments, and a sensitive null detector for precise measurements of integral linearity. Other subjects explored are concerned with space instrumentation, computer applications, detectors, instrumentation for high energy physics, instrumentation for nuclear medicine, environmental monitoring and health physics instrumentation, nuclear safeguards and reactor instrumentation, and a 1984 symposium on nuclear power systems. Attention is given to the application of multiprocessors to scientific problems, a large-scale computer facility for computational aerodynamics, a single-board 32-bit computer for the Fastbus, the integration of detector arrays and readout electronics on a single chip, and three-dimensional Monte Carlo simulation of the electron avalanche in a proportional counter.

Biggerstaff, J. A.↗