Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electric load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Role of Electric Vehicles in the U.S. Power Sector Transition: A System-Level Perspective

After over a century of petroleum dominance many anticipate that electrification could disrupt the transportation energy landscape. At the same time, the electric power systems are undergoing profound changes: variable renewables are displacing conventional generation sources; distributed generation is disrupting utility business models; energy storage and other new technologies are emerging; and the traditional system based on the premise that generation is dispatched to match an inelastic demand is evolving to create a system with greater participation in power system planning and operations from traditionally passive consumers. In this context, it is important to understand how transportation electrification will impact electricity demand and in turn electricity supply, including changes in the load shapes that characterize the system and the opportunity to leverage flexible electric vehicle (EV) charging to better integrate demand and supply. Assessing the impacts of electrification on the energy system requires an understanding of how it might impact the amount and shape of electricity consumption, and how this electricity can be supplied. In particular, increased adoption of electric vehicles introduces a new source of demand altogether, potentially very flexible. Moreover, electrification could shift the consumption of natural gas between sectors, thereby affecting the economics for natural gas-fired generation relative to other electricity generation options. Several factors will impact the evolution of the power system under a widespread electrified future, which, in turn, could have far-reaching effects on future energy costs and emissions.

47 OTHER INSTRUMENTATION↗

Large-Scale Simulation of Regional Demand Flexibility Implementation and Customer Economic Impact

The Distribution System Operator with Transactive (DSO+T) study conducted a large-scale simulation of over 60,000 customers in a region the size of Texas to demonstrate the effective coordination of distributed energy resources (DERs) in commercial and residential buildings. The integrated simulation included both the bulk (wholesale generation and transmission) and distribution systems. The DERs (including batteries, electric vehicles, air conditioning, and water heaters) participated in a transactive energy retail market that was integrated into an existing competitive wholesale market. The engineering and economic performance of the resulting demand flexibility was evaluated over annual simulations for both moderate and high renewable generation scenarios. A detailed parametric cost model was developed to enable detailed economic analysis of key stakeholders. In addition, fixed and dynamic customer tariffs were designed and applied to the customer population. This allowed the impact on annual customer bills to be analyzed for various building types (residential versus commercial; single- versus multi-family). This paper presents results showing the relative flexibility of batteries, electric vehicles, and building loads throughout the year and under different renewable scenarios. This feeds a detailed breakdown of the impact this flexibility has on the operating costs of the grid and the resulting net economic benefit. Finally, the study showed that practically all customer classes (including non-participating customers) save money under the proposed demand flexibility scheme. The study found overall net annual economic savings of $3.3-5.0B for a region the size of Texas equating to average customer bill savings of 10-16%.

Reeve, Hayden M.↗

A Dynamic Pricing Method to Manage the Impact of EV Charging on the Grid Using RL

This work addresses the challenge of managing electrical vehicle (EV) charging loads on distribution feeders with the increase in deployment of fast charging stations. To mitigate the adverse impacts on feeder health, a novel dynamic grid-informed pricing approach is proposed. This approach leverages reinforcement learning (RL) to determine hourly charging prices based on real-time grid conditions. A synthetic environment was developed to train the reinforcement learning agent. A model of an IEEE 34-bus distribution feeder with EV charging stations has been developed in OpenDSS utilizing Caldera for realistic EV charging profiles. Test cases demonstrate that the dynamic pricing strategy achieves higher energy delivery to the EV end user at a lower cost compared to constant pricing methods, while lowering voltage deviations and congestion. This approach offers more granular price adjustments, responding dynamically to feeder conditions and potentially improving grid stability and efficiency. The communication architecture to implement this dynamic pricing method is described. This research contributes to the development of smart grid-informed charging solutions that can reduce the cost of charging to the end user while also helping the grid.

EV charging, dynamic pricing, grid-informed chargi↗

Initial Development of Fusion Magnet Simulation Capabilities for Performance and Safety Evaluation Using the MOOSE Framework

Fusion energy holds the promise of being a transformative technology as a carbon-neutral, sustainable source of energy. Whole device modeling and the development of fusion digital twins will be increasingly important for emerging fusion device concepts at both national laboratories and within the commercial fusion industry. However, meeting the challenge of whole device modeling of fusion energy devices requires robust, multiphysics, multiscale modeling and simulation technologies capable of running on large-scale supercomputers. Detailed analysis of individual systems at-scale is also required to ensure safe and efficient operation as well as provide the safety basis for future device designs and licensing activities. In a tokamak, toroidal and poloidal magnets confine and shape the fusion plasma to promote the fusion reaction. High plasma temperatures and high magnetic field requirements in modern design concepts (leading to high amounts of energy stored within each magnet) impose electrical, thermal, and mechanical loads on the magnet components, which in turn impacts the safety considerations of the magnet and their supporting systems. Idaho National Laboratory (INL) has a history of working in this space, including development and benchmarking of the Magnetic System Circuitry Analysis Program (MSCAP) and Magnet Arcing (MAGARC) codes to study magnet quench events; notably, MAGARC was used to study quenching during the ITER Engineering Design Activity. However, these legacy codes and capabilities are not parallel and scalable, and new tools are required for future advances in this area, which leads to the INL-developed Multiphysics Object-Oriented Simulation Environment (MOOSE) framework. Developed originally for fission reactor systems under United States Department of Energy, Office of Nuclear Energy modeling and simulation programs, the MOOSE framework has been well-suited to multiscale, multiphysics modeling and simulation needs for nuclear systems. The framework is open-source, well-tested, under continuous development and deployment, and developed to a Nuclear Quality Assurance, Level 1 software quality standard. MOOSE has also been used in the fusion space previously in several projects: INL’s Tritium Migration Analysis Program, Version 8 (TMAP8) for tritium migration, UK Atomic Energy Authority’s A Unified Resource for OpenMC (fusion) Reactor Applications (AURORA) code for fusion thermo-mechanical and neutronics analysis, and Argonne National Laboratory’s Cardinal for high-fidelity computational fluid dynamics and neutronics. However, to model superconducting magnets, several MOOSE enhancements are required: additions to the current MOOSE electromagnetic capabilities, new material libraries for superconductors of interest (such as YBCO), as well as fusion-specific models for thermo-mechanics. This talk will discuss initial development activities to build these capabilities in MOOSE, focusing on initial validation and benchmarking activities. Proposed coupling workflows and future work to support the simulation of fusion magnets and magnet structural assemblies for performance and safety evaluation in MOOSE will also be discussed.

70 - PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A dynamic pricing method to manage the impact of EV charging on the grid using RL

This work addresses the challenge of managing electrical vehicle (EV) charging loads on distribution feeders with the increase in deployment of fast charging stations. To mitigate the adverse impacts on feeder health, a novel dynamic grid-informed pricing approach is proposed. This approach leverages reinforcement learning (RL) to determine hourly charging prices based on real-time grid conditions. A synthetic environment was developed to train the reinforcement learning agent. A model of an IEEE 34-bus distribution feeder with EV charging stations has been developed in OpenDSS utilizing Caldera for realistic EV charging profiles. Test cases demonstrate that the dynamic pricing strategy achieves higher energy delivery to the EV end user at a lower cost compared to constant pricing methods, while lowering voltage deviations and congestion. This approach offers more granular price adjustments, responding dynamically to feeder conditions and potentially improving grid stability and efficiency. The communication architecture to implement this dynamic pricing method is described. This research contributes to the development of smart grid-informed charging solutions that can reduce the cost of charging to the end user while also helping the grid.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Field Study of Grid-connected Heat Pump Water Heaters in the Southeast U.S.: The Next Right Thing

The integration of grid-connected functionality and advanced control algorithms into heat pump water heaters (HPWH) offers the capability to shift load with minimal customer impact. This capability provides a flexible grid resource to utilities, while the increased energy efficiency of HPWHs offers customers a lower electric bill. The combined utility/customer value from grid-connected HPWHs is compelling in the Southeast U.S. where residential electric water heating is prevalent and utility load management is common. This paper presents the results of a HPWH load shifting study conducted in Central Florida using the CTA-2045 standard. Building upon previous research in the Pacific Northwest, this study consisted of approximately 45 occupied homes equipped with HPWHs undergoing load shifting strategies weekly for over a year. Curtailment durations ranged from three to five hours in the morning, and four to five hours in the evening to coincide with high-value periods for utility coincident load for system-wide electric demand reductions. During the morning and afternoon, a one- or two-hour load-up event preceded curtailment. Baseline data were collected across varied Florida weather in which no load shifting events were implemented. Results from traditional load shifting strategies were analyzed across seasons and used to devise unique load shifting approaches to increase renewable energy use during periods of high solar energy generation. Regional impacts are forecasted for large-scale implementation of strategies. Lessons learned and recommendations are also provided for how utilities, manufacturers, and regional planners can maximize load shifting benefits from grid-connected HPWHs.

Heat pump water heaters, residential building, loa↗

Offshore Wind Project Study (Final Technical Report)

Within the Long Island electric service territory and throughout New York State there is increasing interest in and mandate for increasing clean energy technologies and renewable energy generation while reducing dependency on fossil fuels for electric production with goal of a carbon free system by 2040. This report discusses the implications of the reduction of forecasted load in the Long Island electric service territory and the impact of energy efficiency; increasing reliance of wind and other renewable resources on the transmission system; opportunities for interconnecting these resources; and reductions on the reliance of baseload fossil fueled power facilities over the coming years.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

National Dataset of EV Charging Stations With Estimates of Load and Vehicle Throughput

Current data from the AFDC provide locations and many details about EV charging stations, but not estimates of their peak loads or the number of vehicles they can accommodate. This dataset will augment the AFDC charging station locations with estimates of transmission load and vehicle throughput based on engineering specifications of the chargers, charging patterns based on vehicle types, battery capacities, and user behavior.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Atomic Oxygen Durability Testing of an International Space Station Solar Array Validation Coupon

An International Space Station solar array validation coupon was exposed in a directed atomic oxygen beam for space environment durability testing at the NASA Lewis Research Center. Exposure to atomic oxygen and intermittent tensioning of the solar array were conducted to verify the solar array#s durability to low Earth orbital atomic oxygen and to the docking threat of plume loading both of which are anticipated over its expected mission life of fifteen years. The validation coupon was mounted on a specially designed rotisserie. The rotisserie mounting enabled the solar and anti-solar facing side of the array to be exposed to directed atomic oxygen in a sweeping arrival process replicating space exposure. The rotisserie mounting also enabled tensioning, in order to examine the durability of the array and its hinge to simulated plume loads. Flash testing to verify electrical performance of the solar array was performed with a solar simulator before and after the exposure to atomic oxygen and tensile loading. Results of the flash testing indicated little or no degradation in the solar array#s performance. Photographs were also taken of the array before and after the durability testing and are included along with comparisons and discussions in this report. The amount of atomic oxygen damage appeared minor with the exception of a very few isolated defects. There were also no indications that the simulated plume loadings had weakened or damaged the array, even though there was some erosion of Kapton due to atomic oxygen attack. Based on the results of this testing, it is apparent that the International Space Station#s solar arrays should survive the low Earth orbital atomic oxygen environment and docking threats which are anticipated over its expected mission life.

Forkapa, Mark J.↗

Elongation Transducer For Tensile Tests

Extensometer transducer measures elongation of tensile-test specimen with negligible distortion of test results. Used in stress-versus-strain tests of small specimens of composite materials. Clamping stress distributed more evenly. Specimen clamped gently between jaw and facing surface of housing. Friction force of load points on conical tips onto specimen depends on compression of spring, adjusted by turning cover on housing. Limp, light nylon-insulated electrical leads impose minimal extraneous loads on measuring elements.

Roberts, Paul W.↗

The 30-cm ion thruster power processor

A power processor unit for powering and controlling the 30 cm Mercury Electron-Bombardment Ion Thruster was designed, fabricated, and tested. The unit uses a unique and highly efficient transistor bridge inverter power stage in its implementation. The system operated from a 200 to 400 V dc input power bus, provides 12 independently controllable and closely regulated dc power outputs, and has an overall power conditioning capacity of 3.5 kW. Protective circuitry was incorporated as an integral part of the design to assure failure-free operation during transient and steady-state load faults. The implemented unit demonstrated an electrical efficiency between 91.5 and 91.9 at its nominal rated load over the 200 to 400 V dc input bus range.

Herron, B. G.↗

Characterization of Epoxy Functionalized Graphite Nanoparticles and the Physical Properties of Epoxy Matrix Nanocomposites

This work presents a novel approach to the functionalization of graphite nanoparticles. The technique provides a mechanism for covalent bonding between the filler and matrix, with minimal disruption to the sp2 hybridization of the pristine graphene sheet. Functionalization proceeded by covalently bonding an epoxy monomer to the surface of expanded graphite, via a coupling agent, such that the epoxy concentration was measured as approximately 4 wt.%. The impact of dispersing this material into an epoxy resin was evaluated with respect to the mechanical properties and electrical conductivity of the graphite-epoxy nanocomposite. At a loading as low as 0.5 wt.%, the electrical conductivity was increased by five orders of magnitude relative to the base resin. The material yield strength was increased by 30% and Young s modulus by 50%. These results were realized without compromise to the resin toughness.

Miller, Sandi G.↗

Flight Performance Estimates for the NASA X-57 Distributed Electric Propulsion Flight Demonstrator

The X-57 flight demonstrator concept featured four configurations starting with a conventional combustion-powered multiengine airplane and ending with a fully electric configuration with two forms of distributed propulsion and a highly modified wing. These configurations, called Mods, were designed to gain incremental insight into different aircraft propulsion configuration options and their impact on the aircraft performance. The gasoline-powered Mod I configuration consumed 2.6 to 2.9 times more stored energy in cruise than the electric but otherwise conventionally configured Mod II configuration. The highly loaded wing of Mod III led to an increase of 40% in the power-off lift-to-drag ratio as compared to Mod II at the project high-speed cruise target speed and altitude. The power-on lift-to-drag ratio of Mod III was 53% higher than Mod II due to the beneficial aero-propulsive interaction of the wingtip-mounted cruise propellers in Mod III. The high-lift propeller system of Mod IV recovered the low-speed performance of the conventional configuration in Mod II that was otherwise lost with the introduction of the highly loaded Mod III wing. The battery-electric configurations also benefitted from a lack of power lapse in the electric motors with increasing air density as compared to the combustion-powered baseline aircraft.

Distributed Performance↗

Flight Performance Estimates for the NASA X-57 Distributed Electric Propulsion Flight Demonstrator

The X-57 flight demonstrator concept featured four configurations starting with a conventional combustion-powered multiengine airplane and ending with a fully electric configuration with two forms of distributed propulsion and a highly modified wing. These configurations, called Mods, were designed to gain incremental insight into different aircraft propulsion configuration options and their impact on the aircraft performance. The gasoline-powered Mod I configuration consumed 2.6 to 2.9 times more stored energy in cruise than the electric but otherwise conventionally configured Mod II configuration. The highly loaded wing of Mod III led to an increase of 40% in the power-off lift-to-drag ratio as compared to Mod II at the project high-speed cruise target speed and altitude. The power-on lift-to-drag ratio of Mod III was 53% higher than Mod II due to the beneficial aero-propulsive interaction of the wingtip-mounted cruise propellers in Mod III. The high-lift propeller system of Mod IV recovered the low-speed performance of the conventional configuration in Mod II that was otherwise lost with the introduction of the highly loaded Mod III wing. The battery-electric configurations also benefitted from a lack of power lapse in the electric motors with increasing air density as compared to the combustion-powered baseline aircraft.

Distributed Performance↗

Electrical conductivity of Sn at high pressure and temperature

To date, temperature and conductivity have many outstanding implications in extreme environments but are yet to be fully understood under high pressure and temperature dynamic conditions. Here, we introduce an approach to provide high quality electrical conductivity results under dynamic loading conditions. Emphasis is given to address the skin depth effect's influence in a dynamic loading experiment by using thin films. The thin film samples in this study were at least 100 times thinner than previous samples in dynamic electrical conductivity experiments, increasing the current density to its full potential across the sample's entire cross section. Consideration of the skin depth accounts for at minimum a 4× scaling factor to the final electrical conductivity result that has been neglected in previous dynamic electrical conductivity studies. We also obtained improved signal-to-noise ratio with custom diagnostics optimized for better electrical impedance matching. Furthermore, these considerations were applied to Sn to assess electrical conductivity at elevated pressure and temperature. The high signal-to-noise ratio with reduced skin depth influence results in Sn allowing observation of the conductivity changes related to solid-to-solid and solid-to-liquid phase transitions. Additionally, we calculate the Sn thermal conductivity using the Wiedemann-Franz law for our experiments and compare against thermal transport dependent temperature measurements from previous work.

36 MATERIALS SCIENCE↗

State Strategies for Valuing Distributed Energy Resources in Cost-Effective Locations

The deployment of Distributed Energy Resources (DERs), small-scale electricity generation sources or controllable loads connected to the distribution system or a facility served by the distribution system, can have wide-ranging and positive impacts for the electricity grid. Interconnecting a DER in a high-value location on the grid can unlock benefits beyond those that accrue to the off-taker or asset owner. When DERs are deployed optimally, not only can the individual consumer benefit, but the local utility, the electricity system, and other ratepayers can benefit as well. By engaging in locational DER planning, states can help protect their communities and ratepayers and can help ensure the reliability and resilience of the electricity system. This report explores states' role in better integrating locational value into DER siting and development. It first outlines some of the benefits that can be achieved through the deployment of DERs in high-value locations. It then looks at state policy and regulatory roles and the tools states can use to influence the location of DER development. The report next examines the challenges of locational DER planning, with a particular focus on the challenges that states face in influencing the location of DER development. It highlights three case studies from states that engaged in locational DER planning through the Multistate Initiative to Develop Solar in Locations that Provide Benefits to the Grid and then presents several lessons learned from these efforts. The final section of this report summarizes some recent publications related to locational value of DERs in the form of an abbreviated literature review.

14 SOLAR ENERGY↗

DISTRIBUTION TRANSFORMER ASSET MONITORING ON THE GRID EDGE USING SMART SENSOR DATA

As new loads such as rooftop photovoltaics, electric vehicles and other distributed energy resources become commonplace on the distribution grid, the stress on already aging assets begins to escalate. This increased loading and changing dynamics can exacerbate failure rates. While traditional monitoring efforts focus on transmission and generation assets, utilities are now beginning to pay close attention to distribution assets in order to increase reliability indices and reduce cost from unexpected outages. This research develops low-cost and scalable methods to monitoring the health of a critical distribution grid asset: the service transformer. Existing methods in literature are either invasive and thus difficult to implement or require the device to be tested offline in an expensive lab setting. Data from the ubiquitous smart meter as well as a novel Bluetooth based transformer monitor are leveraged to automatically notify the utility of deteriorating or damaged transformers. Voltage, temperature, and vibration are some of the signals measured and analyzed by the proposed algorithms to predict transformer failures. Furthermore, these algorithms are designed to keep the implementation and processing costs low by taking advantage of edge computing where possible.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Sintered Cathodes for All-Solid-State Structural Lithium-Ion Batteries

All-solid-state structural lithium ion batteries serve as both structural load-bearing components and as electrical energy storage devices to achieve system level weight savings in aerospace and other transportation applications. This multifunctional design goal is critical for the realization of next generation hybrid or all-electric propulsion systems. Additionally, transitioning to solid state technology improves upon battery safety from previous volatile architectures. This research established baseline solid state processing conditions and performance benchmarks for intercalation-type layered oxide materials for multifunctional application. Under consideration were lithium cobalt oxide and lithium nickel manganese cobalt oxide. Pertinent characteristics such as electrical conductivity, strength, chemical stability, and microstructure were characterized for future application in all-solid-state structural battery cathodes. The study includes characterization by XRD, ICP, SEM, ring-on-ring mechanical testing, and electrical impedance spectroscopy to elucidate optimal processing parameters, material characteristics, and multifunctional performance benchmarks. These findings provide initial conditions for implementing existing cathode materials in load bearing applications.

Ceramics↗