Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Comprehensive analysis of technical efficiency of business establishments in Santa Barbara County: Evaluation of spatial and aspatial stochastic frontier models

One of the main objectives of land-use and transport models is to accurately describe the organization and composition of the regional economy. However, these models currently lack the integration of competitiveness and performance of the regional economy, which in-turn is dependent on performance and efficiency of business establishments in the region. In this study, we present a framework that integrates the aspects of economic efficiency of business establishments within the context of land-use and transport models. For this purpose, we comprehensively assess the impacts of both internal and external attributes of business establishment on its efficiency. In this process, we specifically focus on aspects of incorporating locational characteristics using two frameworks - (a) measuring locational attributes using link-based multiple centrality indicators (L-MCI) and (b) measuring neighborhood effects of business establishments through spatial proximity that account for co-location and competition. We make use of the stochastic frontier modeling framework to investigate the factors impacting business establishment-level output measured as sales per unit area. Specifically, the aspatial stochastic frontier (ASF) model incorporates L-MCI measures as covariates and the spatial stochastic frontier (SSF) model incorporates neighborhood effects of business establishments through network distance measured using the roadway network for Santa Barbara County.Overall, the empirical results suggest that there exist significant inefficiencies across all business establishment types that are mainly impacted by internal attributes of the business. For example, larger and older business establishments are more efficient than business establishments that are smaller in size and younger in age. Furthermore, the results also suggest that locational impacts are better captured using the ASF specification when compared with SSF specification. For instance, the spatial correlation estimate (from SSF) although statistically significant, is very weak. Thereby, indicating a lack of spatial structure in technical efficiency of businesses manifested in the form of co-location and competition. In contrast, the ASF model captures spatial structure of technical efficiency thoroughly with inclusion of the L-MCI measures. This indicates that L-MCI measures have varying levels of impact on efficiency (positive or negative) depending on its relative location in the region. For instance, retail trade businesses have higher levels of revenue (or sales per unit area) when located along links in a grid-network like structure e.g. downtown areas. Additionally, businesses in professional services have no impact on their efficiency based on the configuration and structure of the regional transportation network. However, results from both specifications indicate that there exist major benefits on efficiency of business establishments from local competition for retail trade and healthcare services.

Ravulaparthy, Srinath↗

Lateral Spectrum Splitting Concentrator Photovoltaics: Direct Measurement of Component and Submodule Efficiency

To achieve high energy conversion efficiency, a solar module architecture called lateral spectrum splitting concentrator photovoltaics (LSSCPV) is being developed. LSSCPV can concentrate available sunlight and laterally split a single beam into bands with different spectra for absorption by different solar cells with band gaps matched to the split spectrum. Test assemblies of a sample LSSCPV architecture were constructed, each of which contains four p-n junctions and two optical pieces. Independent experiments or simulations had been implemented on the components but by using optimal assumptions. In order to examine the actual performances of all the components, which are dependent on each other and the light source, direct outdoor measurements were made. A set of self-consistent efficiency definitions was articulated and a test bed was developed to measure the parameters required by the efficiency calculation. By comparing the component efficiency items derived from the outdoor measurement and the expected values based on independent simulations, the potential opportunities for efficiency improvement are determined. In the outdoor measurement at the University of Delaware, the optical component demonstrated 89.1% efficiency. Additional assemblies were tested at the National Renewable Energy Laboratory. One assembly demonstrated 36.7% submodule efficiency, which compares favorably with the 32.6% previously reported verified submodule efficiency.

14 SOLAR ENERGY↗

An experimental and numerical investigation of HD diesel engine DOC efficiency in oxidizing NO to NO 2

Reducing pollutant emissions from heavy-duty (HD) diesel engines is critical due to their significant environmental impact, particularly concerning NOx emissions. Understanding and optimizing modern diesel oxidation catalyst (DOC) and selective catalytic reduction (SCR) performance is essential for improving exhaust aftertreatment (EAT) system efficiency to meet stringent emissions regulations. The oxidation of nitric oxide (NO) to nitrogen dioxide (NO 2 ) in DOC plays a key role in improving SCR efficiency in reducing NO x . This study investigates the DOC performance in oxidizing NO to NO2 and its impact on the SCR efficiency of a 2021 MY Navistar E39 HD diesel engine. The influence of engine speed, load, exhaust gas temperature, and composition on DOC efficiency is experimentally investigated. The relationships between DOC inlet temperature, oxygen availability and NO 2 /NO x ratio at the DOC inlet are examined to better understand their effects on the overall DOC efficiency. The results indicate that DOC NO oxidation efficiency is highly dependent on exhaust temperature, with optimal oxidation occurring within a specific temperature range (275-350°C). Below this threshold, the chemical reactions are kinetically limited, while at higher temperatures, thermodynamic constraints reduce the efficiency of DOC in oxidizing NO to NO 2 . The experimental data further reveal that the NO 2 /NO x ratio peaks at medium loads before declining at higher loads due to reduced residence time and mass transfer effects. Additionally, the SCR NO x conversion efficiency is significantly influenced by the NO 2 /NO x ratio, achieving peak performance when the NO 2 /NO x ratio approaches 0.5. A DOC chemistry model was developed and validated against the experimental data to predict DOC oxidation behavior under various operating conditions. The findings of this study provide insights into the interdependencies between DOC and SCR performance, contributing to the optimization of SCR systems for optimized NOx reduction.

33 ADVANCED PROPULSION SYSTEMS↗

Market and behavioral barriers to energy efficiency: A preliminary evaluation of the case for tariff financing in California

Consumers regularly forgo purchases of high efficiency appliances that appear to be cost effective at a reasonable rate of return. While some argue that this is a true revelation of preferences for appliance features, this 'efficiency gap' can be largely explained by a combination of market and behavioral failures that reduce consumers ability to evaluate the relative value of appliances and skew preferences toward initial cost savings, undervaluing future reductions in operating costs. These failures and barriers include externalities of energy use, imperfect competition between manufacturers, asymmetric information, bounded rationality, split incentives, and transaction costs (Golove 1996). Recognizing the social benefit of energy conservation, several major methods are used by policymakers to ensure that efficient appliances are purchased: minimum efficiency standards, Energy Star labeling, and rebates and tax credits. There is no single market for energy services; there are hundreds of uses, thousands of intermediaries, and millions of users, and likewise, no single appropriate government intervention (Golove 1996). Complementary approaches must be implemented, considering policy and institutional limitations. In this paper, I first lay out the rationale for government intervention by addressing the market and behavioral failures and barriers that arise in the context of residential energy efficiency. I then consider the ways in which some of these failures and barriers are addressed through major federal programs and state and utility level programs that leverage them, as well as identifying barriers that are not addressed by currently implemented programs. Heterogeneity of consumers, lack of financing options, and split incentives of landlords and tenants contribute significantly to the under-adoption of efficient appliances. To quantify the size of the market most affected by these barriers, I estimate the number of appliances, and in particular the number of outdated appliances, in California rental housing. Appliances in rental housing are on average older than those in owner occupied housing. More importantly, a substantial proportion of very old appliances are in rental housing. Having established that a very old stock of appliances exists in California rental housing, I discuss tariff financing as a policy option to reduce the impact of the remaining market and behavioral barriers. In a tariff financing program, the utility pays the initial cost of an appliance, and is repaid through subsequent utility bills. By eliminating upfront costs, tying repayment to the gas or electric meter, requiring a detailed energy audit, and relying upon utility bill payment history rather than credit score in determining participant eligibility, tariff financing largely overcomes many barriers to energy efficiency. Using California as a case study, I evaluate the feasibility of implementing tariff financing. For water heaters in particular, this appears to be a cost-effective strategy. Tariff financing from utilities is particularly valuable because it improves the ability of low-income renters to lower their utility bills, without burdening landlords with unrecoverable capital costs. To implement tariff financing country-wide, regulations in many states defining private loan-making institutions or the allowable use of public benefit funds may need to be modified. Tariff financing is relatively new and in most locations is only available as a pilot program or has only recently exited pilot phase. This preliminary evaluation suggests that tariff financing is a valuable future addition to the toolkit of policymakers who aim to increase the diffusion of efficient appliances. While regulatory approval is necessary in states that wish to pursue tariff financing, at this point, the major barrier to further implementation appears to be the newness of the financing mechanism.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Trends in best-in-class energy-efficient technologies for room air conditioners

Improving the efficiency of room air conditioners (RACs) could provide significant energy and associated emissions savings, particularly in emerging economies with hot climates where the cooling demand is expected to increase dramatically. To help accelerate efficiency improvements, this study identifies “best-in-class” high-efficiency RAC components and products. The findings show that manufacturers tend to minimize manufacturing costs by using RAC designs that are readily available or standardized to their production, and they share components across various models. High-efficiency RAC models use advanced compressor technologies optimized at a low frequency, large heat exchangers with thermodynamically effective materials and designs, highly efficient direct current fan motors, advanced metering devices, and smart sensors for temperature and humidity control. Recently RAC manufacturers have been improving seasonal efficiency – better reflecting part-load operation – especially via variable-speed (inverter) drives for compressor motors. Recent highest-efficiency RAC models use low global warming potential (GWP) refrigerants, having transitioned from conventional high-GWP refrigerants, in regions where RACs that use these low-GWP refrigerants are commercially available. Recently demonstrated innovative technologies show trends toward smart hybrid designs, evaporative cooling, and solid-state materials beyond the conventional vapor-compression technology. This information could help policymakers improve their RAC market-transformation programs to align with the most-efficient global technology.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A High-Efficient Solution for Electro-Hydraulic Actuators with Energy Regeneration Capability

This paper proposes a cost-effective, robustly practical solution for a high-efficient electro-hydraulic actuator (EHA) for linear drives. The solution addresses the challenges of high costs and limited efficiency that limit the application of EHA for the electrification of many off-road vehicles. Based on a variable-speed electric motor and a low-cost technology for a fixed-displacement pump, the proposed solution is suitable for a compact implementation and it is capable of energy regeneration under overrunning load conditions. Two different architectures—an open circuit and a closed circuit one—are considered to determine the most practical and efficient configuration as well as the control features. Both architectures minimize throttling losses associated with the conventional regulation of hydraulic actuators. Actuator velocities below the minimum and beyond the maximum allowable pump flow rate are achieved in both architectures using a proportional valve that bypasses the pump flow. The paper describes the design methodology as well as the simulation and experimental activities performed to verify the control strategies as well as energy efficiency. Considering an EHA system of about 20 kW, a complete efficiency map of the system is determined for all the possible four quadrants of operation thus including both resistive and overrunning loads, where energy recuperation is implemented. Simulation and experimental results show that the energy efficiency of the hydraulic systems can reach 84.7% in resistive phases. In assistive phases, the hydraulic system can recover up to 81.8% of the actuator energy. Here, the comparison between open-circuit and closed-circuit structures shows the advantages of the former in terms of energy efficiency. The proposed solution is suitable for electrified hydraulic actuation systems, in both industrial and mobile applications. With the advantages of the low cost of the hydraulic unit and high energy efficiency, it is particularly suitable for mobile applications such as construction machines, that are recently experiencing a significant electrification trend.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Simulated CO 2 storage efficiency factors for saline formations of various lithologies and depositional environments using new experimental relative permeability data

Saline formations are attractive geologic reservoirs for permanent carbon dioxide (CO 2 ) storage. Here, the U.S. Department of Energy's National Energy Technology Laboratory (DOE-NETL) has worked to develop and refine methods and tools for the calculation of CO 2 storage potential in subsurface reservoirs. DOE-NETL's CO 2 -SCREEN provides an online tool for executing these storage methods. CO 2 storage efficiency terms are input parameters in DOE-NETL's methods and equations embedded in the CO 2 -SCREEN, which assesses pore space available for CO 2 storage. In this work, a modeling workflow was initiated to refine two CO 2 storage efficiency terms - volumetric displacement (E V ) and microscopic displacement (E d ). The models are based on new experimental relative permeability data that are specific to homogenous lithology and depositional environments of key subsurface saline formations targeted for CO 2 storage. In future work, heterogenous features will be added to this initial modeling effort to update efficiency factors as described in DOE-NETL's methods and CO 2 -SCREEN tool. E V accounts for the volume utilized in the reservoir under the areal plume, while E d accounts for saturation values in the plume to assess efficiency of CO 2 storage at the pore scale. The results of this work are significant in that prior values were based on a limited geologically non-specific relative permeability data set that were collected prior to 2009. Specifically, we applied numerical simulations using TOUGH3 models to update CO 2 storage efficiency values for supercritical CO 2 injection into brine-saturated reservoirs for three lithologies (clastics, limestone, dolomite) and six depositional environments (Marginal Marine, Strand Plain, Deltaic Complex Fluvial, Aeolian, Shallow Marine, and Reef) that have a high potential for geologic CO 2 storage. Experimental relative permeability data in cores from these environments were utilized in the models with corresponding rock type/sedimentary environment. Results of this study showed that dolomite followed by limestone generated higher ranges of storage efficiency compared to clastics. The updated values provided a tighter efficiency range for clastics, lower P 10 but higher P 90 range for limestone, and higher P 10 and P 90 for dolomite. In general, tighter reservoirs with relatively low permeability and porosity were associated with higher E V and E d , showing efficient reservoir and pore utilization in these scenarios. High reservoir pressure and temperature associated with increasing depth increased the E V , and high CO 2 injection rates resulted in increases in E V and E d , while the impact of permeability anisotropy was minimal after the 30-year injection period.

03 NATURAL GAS↗

Multiresolution molecular mechanics: Implementation and efficiency

Atomistic/continuum coupling methods combine accurate atomistic methods and efficient continuum methods to simulate the behavior of highly ordered crystalline systems. Coupled methods utilize the advantages of both approaches to simulate systems at a lower computational cost, while retaining the accuracy associated with atomistic methods. Many concurrent atomistic/continuum coupling methods have been proposed in the past; however, their true computational efficiency has not been demonstrated. The present work presents an efficient implementation of a concurrent coupling method called the Multiresolution Molecular Mechanics (MMM) for serial, parallel, and adaptive analysis. First, we present the features of the software implemented along with the associated technologies. The scalability of the software implementation is demonstrated, and the competing effects of multiscale modeling and parallelization are discussed. Then, the algorithms contributing to the efficiency of the software are presented. These include algorithms for eliminating latent ghost atoms from calculations and measurement-based dynamic balancing of parallel workload. The efficiency improvements made by these algorithms are demonstrated by benchmark tests. The efficiency of the software is found to be on par with LAMMPS, a state-of-the-art Molecular Dynamics (MD) simulation code, when performing full atomistic simulations. Speed-up of the MMM method is shown to be directly proportional to the reduction of the number of the atoms visited in force computation. Finally, an adaptive MMM analysis on a nanoindentation problem, containing over a million atoms, is performed, yielding an improvement of 6.3–8.5 times in efficiency, over the full atomistic MD method. For the first time, the efficiency of a concurrent atomistic/continuum coupling method is comprehensively investigated and demonstrated.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Amorphous MoS{sub x} on CdS nanorods for highly efficient photocatalytic hydrogen evolution

Loading cocatalyst on semiconductors was crucially necessary for improving the photocatalytic hydrogen evolution. Amorphous MoS{sub x} as a novel and noble metal-free cocatalyst was loaded on CdS nanorods by a simple photodeposition method. Efficient hydrogen evolution with amount of 15 mmol h{sup −1} g{sup −1} was observed over the MoS{sub x} modified CdS nanorods, which was about 6 times higher than that by using Pt as cocatalyst. Meanwhile, with MoS{sub x} cocatalyst, the efficiency of CdS nanorods was superior to that of CdS nanoparticles and bulk CdS. No deactivation could be observed in the efficiency of MoS{sub x} modified CdS nanorods under irradiation for successive 10 h. Further experimental results indicated that the efficient electrons transfer, low overpotential of hydrogen evolution and active S atoms over the MoS{sub x} modified CdS nanorods were responsible for the higher efficiency. Our results provided guidance for synthesizing noble metal-free materials as cocatalyst for photocatalytic hydrogen evolution. - Graphical abstract: Photodeposition of amorphous MoS{sub x} on CdS nanorods for highly efficient photocatalytic hydrogen evolution. - Highlights: • Amorphous MoSx cocatalyst was loaded on CdS NRs by a simple photodeposition. • MoS{sub x}/CdS NRs exhibited 6 times higher hydrogen evolution efficiency than Pt/CdS NRs. • The hydrogen evolution of MoS{sub x}/CdS NRs linearly increased with prolonging time. • Lower overpotential and efficient electron transfer were observed over MoS{sub x}/CdS NRs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

THE EFFICIENCY AND WAVELENGTH DEPENDENCE OF NEAR-INFRARED INTERSTELLAR POLARIZATION TOWARD THE GALACTIC CENTER

Near-infrared polarimetric imaging observations toward the Galactic center (GC) have been carried out to examine the efficiency and wavelength dependence of interstellar polarization. A total area of about 5.7 deg{sup 2} is covered in the J, H, and K{sub S} bands. We examined the polarization efficiency, defined as the ratio of the degree of polarization to color excess. The interstellar medium between the GC and us shows a polarization efficiency lower than that in the Galactic disk by a factor of three. Moreover we investigated the spatial variation of the polarization efficiency by comparing it with that of the color excess, degree of polarization, and position angle. The spatial variations of color excess and degree of polarization depend on the Galactic latitude, while the polarization efficiency varies independently of the Galactic structure. Position angles are nearly parallel to the Galactic plane, indicating a longitudinal magnetic field configuration between the GC and us. The polarization efficiency anticorrelates with dispersions of position angles. The low polarization efficiency and its spatial variation can be explained by the differences in the magnetic field directions along the line of sight. From the lower polarization efficiency, we suggest a higher strength of a random component relative to a uniform component of the magnetic field between the GC and us. We also derived the ratios of degree of polarization p{sub H} /p{sub J} = 0.581 {+-} 0.004 and p{sub K{sub S}}/p{sub H} = 0.620 {+-} 0.002. The power-law indices of the wavelength dependence of polarization are {beta}{sub JH} = 2.08 {+-} 0.02 and {beta}{sub HK{sub S}} = 1.76 {+-} 0.01. Therefore, the wavelength dependence of interstellar polarization exhibits flattening toward longer wavelengths in the range of 1.25-2.14 {mu}m. The flattening would be caused by aligned large-size dust grains.

79 ASTRONOMY AND ASTROPHYSICS↗

The high-efficiency jets magnetically accelerated from a thin disk in powerful lobe-dominated FRII radio galaxies

A maximum jet efficiency line R ∼ 25 (R = L {sub jet}/L {sub bol}), found in FRII radio galaxies by Fernandes et al., was extended to cover the full range of jet power by Punsly. Recent general relativistic magnetohydrodynamic simulations of jet formation have mainly focused on the enhancement of jet power. In this work, we suggest that the jet efficiency could be very high even for conventional jet power if the radiative efficiency of disks was much smaller. We adopt the model of a thin disk with magnetically driven winds to investigate the observational high-efficiency jets in FRII radio galaxies. It is found that the structure of a thin disk can be significantly altered by the feedback of winds. The temperature of a disk gradually decreases with increasing magnetic field; the disk density, surface density, and pressure also change enormously. The lower temperature and higher surface density in the inner disk result in the rapid decrease of radiative efficiency. Thus, the jet efficiency is greatly improved even if the jet power is conventional. Our results can explain the observations quite well. The theoretical maximum jet efficiency of R ∼ 1000 suggested by our calculations is large enough to explain all of the high jet efficiency in observations, even considering the episodic activity of jets.

79 ASTRONOMY AND ASTROPHYSICS↗

Simple Retrofit High-Efficiency Natural Gas Water Heater Field Test

High performance water heaters are typically more time consuming and costly to install in retrofit applications, making high performance water heaters difficult to justify economically. However, recent advancements in high performance water heaters have targeted the retrofit market, simplifying installations and reducing costs. Four high efficiency natural gas water heaters designed specifically for retrofit applications were installed in single-family homes along with detailed monitoring systems to characterize their savings potential, their installed efficiencies, and their ability to meet household demands. The water heaters tested for this project were designed to improve the cost-effectiveness and increase market penetration of high efficiency water heaters in the residential retrofit market. The retrofit high efficiency water heaters achieved their goal of reducing costs, maintaining savings potential and installed efficiency of other high efficiency water heaters, and meeting the necessary capacity in order to improve cost-effectiveness. However, the improvements were not sufficient to achieve simple paybacks of less than ten years for the incremental cost compared to a minimum efficiency heater. Significant changes would be necessary to reduce the simple payback to six years or less. Annual energy savings in the range of $200 would also reduce paybacks to less than six years. These energy savings would require either significantly higher fuel costs (greater than $1.50 per therm) or very high usage (around 120 gallons per day). For current incremental costs, the water heater efficiency would need to be similar to that of a heat pump water heater to deliver a six year payback.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simple Retrofit High-Efficiency Natural Gas Water Heater Field Test

High-performance water heaters are typically more time consuming and costly to install in retrofit applications, making high performance water heaters difficult to justify economically. However, recent advancements in high performance water heaters have targeted the retrofit market, simplifying installations and reducing costs. Four high efficiency natural gas water heaters designed specifically for retrofit applications were installed in single-family homes along with detailed monitoring systems to characterize their savings potential, their installed efficiencies, and their ability to meet household demands. The water heaters tested for this project were designed to improve the cost-effectiveness and increase market penetration of high efficiency water heaters in the residential retrofit market. The retrofit high efficiency water heaters achieved their goal of reducing costs, maintaining savings potential and installed efficiency of other high efficiency water heaters, and meeting the necessary capacity in order to improve cost-effectiveness. However, the improvements were not sufficient to achieve simple paybacks of less than ten years for the incremental cost compared to a minimum efficiency heater. Significant changes would be necessary to reduce the simple payback to six years or less. Annual energy savings in the range of $200 would also reduce paybacks to less than six years. These energy savings would require either significantly higher fuel costs (greater than $1.50 per therm) or very high usage (around 120 gallons per day). For current incremental costs, the water heater efficiency would need to be similar to that of a heat pump water heater to deliver a six year payback.

03 NATURAL GAS↗

The Energy in Modular (EMOD) Buildings Method: A Guide to Energy-Efficient Design for Industrialized Construction of Modular Buildings

Industrialized construction has immense potential to address the growing need globally to build and upgrade the building stock to be affordable, energy-efficient, and resilient. It can also help achieve the United States' goal of a 50% reduction in U.S. greenhouse gas (GHG) emissions by 2030. Despite this potential, and the ever-increasing push for electrification and decarbonization of households in the United States, industrialized construction has not yet been leveraged specifically to help address these challenges and accelerate the pathway to meet these goals. The National Renewable Energy Laboratory (NREL) aims to claim this missed opportunity by focusing on delivering affordable, grid-efficient net-zero energy (NZE) modular buildings for underserved communities to ensure an equitable transition to the future of clean energy, accelerate decarbonization of the built environment, and support the development of a high-productivity construction and energy efficiency workforce. The Energy in Modular (EMOD) method is our approach to designing, producing, and delivering affordable, net-zero energy, low-carbon, and healthier buildings at scale. The following energy efficiency strategies are part of the scope of this guide: envelope thermal control, envelope infiltration control, mechanical, electrical, and plumbing systems, smart controls, and solar plus storage. We draw synergies between design for manufacturing and assembly, process optimization, retrofit technologies, and digitization. Our goal is to influence the improvement and production of buildings to increase performance, enhance energy efficiency, and reduce GHG emissions. This guide documents the research and development efforts initiated by a set of design objectives to "modularize" a set of energy efficiency and low-carbon strategies into a housing unit while preserving and enhancing energy efficiency benefits and decarbonization pathways. This guide is intended to serve as a framework for housing developers, housing agencies, architects, energy experts, and process engineers or factory operator personnel who are critical to today's modular builder teams. This guide focuses on specific energy efficiency strategies, decarbonization pathways, and associated processes as part of NREL's research efforts. Stakeholders may substitute other means, methods, and technologies for the ones evaluated in this study.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Modeling Toolkit for Comparing AC and DC Electrical Distribution Efficiency in Buildings

Recently, there has been considerable research interest in the potential for DC distribution systems in buildings instead of the traditional AC distribution systems. Due to the need for performing power conversions between DC and AC electricity, DC distribution may provide electrical efficiency advantages in some systems. To support comparative evaluations of AC-only, DC-only, and hybrid AC/DC distribution systems in buildings, a new modeling toolkit called the Building Electrical Efficiency Analysis Model (BEEAM) was developed and is described in this paper. To account for harmonics in currents or voltages arising from nonlinear devices, the toolkit implements harmonic power flow, along with nonlinear device behavioral descriptions derived from empirical measurements. This paper describes the framework, network equations, device representations, and an implementation of the toolkit in an open source software package, including a component library and graphical interface for creating circuits. Simulations of electrical behavior and device and system efficiencies using the toolkit are compared with experimental measurements of a small office environment in a variety of operating and load configurations. A detailed analysis of uncertainty estimation is also provided. Key findings were that a comparison of predicted versus measured efficiencies and power losses in the validation testbed using the initial toolkit implementation predicted device- and system-level efficiencies with reasonably good accuracy under both balanced and unbalanced AC scenarios. An uncertainty analysis also revealed that the maximum estimated error for system efficiency across all scenarios was 3%, and measured and modeled system efficiency agreed within the experimental uncertainty in approximately half of the scenarios. Based on the correspondence between simulation and measurement, the toolkit is proposed by the authors as a potentially useful tool for comparing efficiency in AC, DC, and hybrid AC/DC distribution systems in buildings.

DC distribution↗

Unlocking Energy Efficiency: Debunking Myths on the Road to Decarbonization

Energy efficiency is widely recognized as the foundational and most critical strategy for decarbonizing the manufacturing sector. Misconceptions surrounding energy efficiency measures often hinder their widespread adoption. This article aims to debunk five common myths and provides data and resources to help implement efficiency projects faster and more effectively to achieve greater decarbonization. First, the article challenges the myth that organizations have exhausted all possible energy efficiency opportunities by achieving voluntary energy intensity goals or energy performance certification. Second, it also addresses the misconceptions that efficiency projects are capital-intensive, require many qualified specialists, and have long investment return periods. By presenting real-world case studies and referencing commonly found efficiency opportunities, the article illustrates that energy-savings opportunities are ubiquitous. Organizations can use various contracting mechanisms as well as financial and technical resources from utility companies and government programs to lessen their burden. The notion that efficiency measures can be implemented solely in proprietorship facilities is dispelled. This article emphasizes the importance of green leases and explains that aligning decarbonization goals between the lessor and lessee can help drive savings for both parties. Finally, using unbundled renewable energy certificates as the sole pathway to decarbonization is strongly discouraged. By debunking these prevalent myths, this article aims to foster a deeper understanding of energy efficiency’s potential as a cornerstone of decarbonization efforts and to embrace it as a critical pathway toward a sustainable future.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The star formation rate efficiency of neutral atomic-dominated hydrogen gas in the outskirts of star-forming galaxies from z ∼ 1 to z ∼ 3

Current observational evidence suggests that the star formation rate (SFR) efficiency of neutral atomic hydrogen gas measured in damped Lyα systems (DLAs) at z∼3 is more than 10 times lower than predicted by the Kennicutt–Schmidt (KS) relation. To understand the origin of this deficit, and to investigate possible evolution with redshift and galaxy properties, we measure the SFR efficiency of atomic gas at z ∼ 1, z ∼ 2, and z∼3 around star-forming galaxies. We use new robust photometric redshifts in the Hubble Ultra Deep Field to create galaxy stacks in these three redshift bins, and measure the SFR efficiency by combining DLA absorber statistics with the observed rest-frame UV emission in the galaxies’ outskirts. We find that the SFR efficiency of H i gas at z>1 is ∼1%–3% of that predicted by the KS relation. Contrary to simulations and models that predict a reduced SFR efficiency with decreasing metallicity and thus with increasing redshift, we find no significant evolution in the SFR efficiency with redshift. Our analysis instead suggests that the reduced SFR efficiency is driven by the low molecular content of this atomic-dominated phase, with metallicity playing a secondary effect in regulating the conversion between atomic and molecular gas. This interpretation is supported by the similarity between the observed SFR efficiency and that observed in local atomic-dominated gas, such as in the outskirts of local spiral galaxies and local dwarf galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

Building America Case Study: Simple Retrofit High-Efficiency Natural Gas Water Heater Field Test, Minneapolis, Minnesota

High performance water heaters are typically more time consuming and costly to install in retrofit applications, making high performance water heaters difficult to justify economically. However, recent advancements in high performance water heaters have targeted the retrofit market, simplifying installations and reducing costs. Four high efficiency natural gas water heaters designed specifically for retrofit applications were installed in single-family homes along with detailed monitoring systems to characterize their savings potential, their installed efficiencies, and their ability to meet household demands. The water heaters tested for this project were designed to improve the cost-effectiveness and increase market penetration of high efficiency water heaters in the residential retrofit market. The retrofit high efficiency water heaters achieved their goal of reducing costs, maintaining savings potential and installed efficiency of other high efficiency water heaters, and meeting the necessary capacity in order to improve cost-effectiveness. However, the improvements were not sufficient to achieve simple paybacks of less than ten years for the incremental cost compared to a minimum efficiency heater. Significant changes would be necessary to reduce the simple payback to six years or less. Annual energy savings in the range of $200 would also reduce paybacks to less than six years. These energy savings would require either significantly higher fuel costs (greater than $1.50 per therm) or very high usage (around 120 gallons per day). For current incremental costs, the water heater efficiency would need to be similar to that of a heat pump water heater to deliver a six year payback.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗