Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “deployment strategy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Characterizing Plug Load Energy Use and Savings Potential in Army Buildings

The Assistant Secretary of the Army (Installations, Energy and Environment) tasked the Pacific Northwest National Laboratory to examine plug loads in typical Army buildings. Plug loads (also known as miscellaneous electric loads (MELs)) represent the electricity used by appliances and devices that are plugged in or hardwired and serve functions outside of a building’s core end uses. Common plug loads include computers, printers, copiers, networking devices, refrigerators, and vending machines. They also include personal electronic devices such as televisions, smart phones, tablets, and gaming systems. Examples of hardwired MELs include elevators, air compressors, and fire and security systems. The findings from this study confirm that significant energy is consumed within Army buildings by plug load devices and hardwired MEL equipment. A number of opportunities are identified for reducing unnecessary energy use that could save the Army over $5 million per year when broadly applied. Army regulations clearly spell out expectations for the purchase and operation of information technology equipment (computers, laptops, monitors, printers, and multi-function devices). However, the policies regarding the shutdown or activation of sleep and other lower power modes after 30 minutes of inactivity (15 minutes for monitors) do not appear to be consistently followed. There are many effective approaches and pathways for impacting change as it relates to improving awareness, implementing measures, and adjusting behaviors to identify and reduce plug load energy use. The Army should prioritize and consider deploying all of these to better understand and manage plug load equipment to save energy and enhance resilience across their facilities. Engaging the building occupants who use these devices daily via outreach and education should be a strong component of the strategy. The focus should be on reducing waste without sacrificing productivity or the benefits that many of these devices provide. Continued evaluation of plug loads beyond that performed here is important to gather lessons from additional building and equipment types, and to stay aware of evolving device technology and management options. This will highlight additional needs for policies, best practices, control technologies, and education of personnel to achieve real reductions in energy waste from plug load equipment. It is recommended that this study may serve as the foundation for a broader and sustained focus on plug loads and MELs, towards simultaneously enhancing the productivity, readiness, and resilience of the Army while reducing energy use and demand, and freeing up resources to better support the mission.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Stabilizing the Grid and Reducing Utility Bills Through Price-Responsive Controls for Heat Pump Water Heaters

The electricity grid is facing increasing challenges in cost-effectively balancing supply and demand. These challenges are exacerbated by increased penetration of photovoltaics, which causes mid-day overproduction, and electrification of gas appliances, which increases peak-period electricity demand. Decarbonization requires shifting building loads from fossil-intensive high-cost times to renewable-intensive low-cost times while maintaining quality of service to occupants. Utilities and ISO’s are investigating new ways of incentivizing this load shifting. One promising method is the use of Highly Dynamic Prices (HDPs). HDPs feature continuously changing prices that reflect real-time grid generation and distribution costs and capacity constraints, and thus incentivize consumers to shift their loads. California’s CPUC CalFUSE proposal and Hawaii’s recent changes demonstrate that electricity tariffs are moving towards this model. For this to work however, loads must have the capability to respond to these prices. Heat pump water heaters (HPWHs) are an ideal device for this purpose because their storage tanks decouple delivery of domestic hot water from electricity consumption. The storage enables control strategies that consume midday solar power to increase the energy stored in the tank, then provide evening peak domestic hot water services using the stored energy. Berkeley Lab's CalFlexHub project is pioneering price-driven load flexibility by developing and deploying cost-minimizing controls for many flexible loads - including HPWHs - in response to HDP. Control development is based on simulations using the Flexible Heat Pump Water Heater Performance Predictor which captures the control decisions of the on-board controller in a residential, integrated HPWH . The price-responsive controls a) shift load in ways that consume additional midday solar power to help stabilize the grid and reduce overall emissions, b) ensure that occupants receive equal or better hot water delivery service, and c) minimize the operating cost for each home in the fleet. On the grid level, the resulting shift will reduce utility operating costs and emissions, and can avoid expensive system capacity expansions. The control approach is customized to each home based on typical hot water consumption patterns. HPWH controllers, whether on the device or remotely, will receive a schedule of CTA-2045-B signals or set temperature adjustments customized to the current HDP price schedule and home. Simulation results for a fleet of 148 HPWHs on a summer day in Berkeley, California show cost savings of 29% and high price electricity consumption reductions of 80%, while maintaining full quality of service.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Collaborative Supervised Learning for Sensor Networks

Collaboration methods for distributed machine-learning algorithms involve the specification of communication protocols for the learners, which can query other learners and/or broadcast their findings preemptively. Each learner incorporates information from its neighbors into its own training set, and they are thereby able to bootstrap each other to higher performance. Each learner resides at a different node in the sensor network and makes observations (collects data) independently of the other learners. After being seeded with an initial labeled training set, each learner proceeds to learn in an iterative fashion. New data is collected and classified. The learner can then either broadcast its most confident classifications for use by other learners, or can query neighbors for their classifications of its least confident items. As such, collaborative learning combines elements of both passive (broadcast) and active (query) learning. It also uses ideas from ensemble learning to combine the multiple responses to a given query into a single useful label. This approach has been evaluated against current non-collaborative alternatives, including training a single classifier and deploying it at all nodes with no further learning possible, and permitting learners to learn from their own most confident judgments, absent interaction with their neighbors. On several data sets, it has been consistently found that active collaboration is the best strategy for a distributed learner network. The main advantages include the ability for learning to take place autonomously by collaboration rather than by requiring intervention from an oracle (usually human), and also the ability to learn in a distributed environment, permitting decisions to be made in situ and to yield faster response time.

Wagstaff, Kiri L.↗

A comprehensive review on regeneration strategies for direct air capture

Direct air capture (DAC), which removes CO 2 directly from ambient air, is a critical negative emission technology for mitigating global climate change. Efficiency and the source of energy are crucial considerations for DAC to enable negative emissions. Substantial technological progress has been made in DAC technologies, and promising opportunities exist for commercial-scale deployments. However, DAC technologies require high regeneration energy to release CO 2 from sorbents. Various approaches have been tested and optimized for different DAC systems. This review demonstrates that the work equivalent regeneration energy demand (supported by either the electric grid or fossil fuel combustion) ranges from 0.5–18.75 GJ/t-CO 2 for solid sorbent DAC systems and 0.62–17.28 GJ/t-CO 2 for liquid solvent DAC systems. The regeneration process is the energy-demanding process in DAC that is a key step for efficient operation. Potential methods to lower the regeneration energy demand include microwave, ultrasound, magnetic particle heating, and electric swing. Although the potential methods to date are still at the lab scale, significant work is being done to optimize DAC system processes.

54 ENVIRONMENTAL SCIENCES↗

Targeting CCL2/CCR2 Signaling Overcomes MEK Inhibitor Resistance in Acute Myeloid Leukemia

Emerging evidence underscores the critical role of extrinsic factors within the microenvironment in protecting leukemia cells from therapeutic interventions, driving disease progression, and promoting drug resistance in acute myeloid leukemia (AML). This finding emphasizes the need for the identification of targeted therapies that inhibit intrinsic and extrinsic signaling to overcome drug resistance in AML. We performed a comprehensive analysis utilizing a cohort of ~300 AML patient samples. This analysis encompassed the evaluation of secreted cytokines/growth factors, gene expression, and ex vivo drug sensitivity to small molecules. Our investigation pinpointed a notable association between elevated levels of CCL2 and diminished sensitivity to the MEK inhibitors (MEKi). We validated this association through loss-of-function and pharmacologic inhibition studies. Further, we deployed global phosphoproteomics and CRISPR/Cas9 screening to identify the mechanism of CCR2-mediated MEKi resistance in AML. Our multifaceted analysis unveiled that CCL2 activates multiple prosurvival pathways, including MAPK and cell-cycle regulation in MEKi-resistant cells. Employing combination strategies to simultaneously target these pathways heightened growth inhibition in AML cells. Both genetic and pharmacologic inhibition of CCR2 sensitized AML cells to trametinib, suppressing proliferation while enhancing apoptosis. These findings underscore a new role for CCL2 in MEKi resistance, offering combination therapies as an avenue to circumvent this resistance. Our study demonstrates a compelling rationale for translating CCL2/CCR2 axis inhibitors in combination with MEK pathway-targeting therapies, as a potent strategy for combating drug resistance in AML. This approach has the potential to enhance the efficacy of treatments to improve AML patient outcomes.

60 APPLIED LIFE SCIENCES↗

Enter the AHU (36th Chamber of ASHRAE): A Multi-site Field Study of ASHRAE G36

Despite being recognized as the best practice for advanced building controls, ASHRAE Guideline 36 (G36) has seen slow adoption in retrofit cases. Decisionmakers lack credible field evidence to justify the time and person-power investment. Most prior analyses have relied on software simulations, which overlook implementation challenges and fail to persuade owners to move from models to real-world deployment. This paper presents a multi-site field study of G36 performance, drawing on measured results from 17 projects across diverse building types and climate zones. The analysis disaggregates outcomes by the most widely adopted air handling unit (AHU) based G36 strategies, including trim-and-respond approaches to supply air temperature (SAT) and duct static pressure (DSP) reset, and economizer controls. Results for controls re programming implementations are encouraging, with HVAC savings ranging from 2% - 49%, with a median of 18%. The range aligns with simulation study findings showing 1% - 46% savings through these three strategies. These findings show that even without capital investment in control infrastructure upgrades, existing building owners are reaping significant benefits from updating HVAC sequences of operation to industry best-practice solutions. The results give practitioners and decisionmakers a reference point on what to expect, which strategies deliver, and how field performance may compare to simulation.

Deshpande, Reva↗

Rapid SACR Observations of Convection at Bankhead National Forest (RAPID) Field Campaign Report

Improving our representation of convective cell processes requires better quantification of convective clouds throughout their entire life cycle. This includes gaining a clearer understanding of the controls on key convective cloud properties, such as updraft intensity, particle size distributions, rainfall rates, and hydrometeor species. Our inability to improve convective cloud process modeling stems, in part, from a limited understanding of convective cell properties, particularly given how rapidly these storms evolve. This lack of detailed observations in the most intense and organized convective storms is especially significant, as large errors remain in representing these clouds, which are critical for severe weather prediction and Earth system model performance. Cloud and precipitation radars are essential tools for studying cloud microphysics and dynamics, particularly in deeper convective clouds. The recent U.S. Department of Energy Atmospheric Radiation Measurement (ARM) User Facility’s third Mobile Facility (AMF3) Bankhead National Forest (BNF) deployment provides a unique opportunity to investigate important land–atmosphere interactions, as well as the environmental controls on deep convective cloud processes, in a location favorable for frequent convection. We operate the X/Ka-band Scanning ARM Cloud Radar (X/Ka SACR) using a scan strategy optimized to capture these rapidly evolving clouds and their properties, thereby improving studies of deep convective cloud processes. This effort is strengthened by a complementary and coordinated partnership with ongoing university and multi-agency radar activities collocated in north Alabama—a unique opportunity to examine clouds and precipitation from a lifetime-centric perspective.

54 ENVIRONMENTAL SCIENCES↗

FOCAL Campaign IV: Integrated System Control: Turbine + Hull

Campaign IV of the Floating Offshore-wind Controls Advanced Laboratory Experimental Program (FOCAL) aimed to generate a dataset enabling the validation of a floating offshore wind turbine with turbine and hull controls. The turbine considered in this campaign is the scaled IEA 15MW Reference Wind Turbine similar to the setup considered in FOCAL Campaign I. This turbine is mounted on the VolturnUS platform with integrated hull controls similar to the hull considered in FOCAL Campaign II/III. This system is deployed for a fully-coupled wind and wave testing campaign at the University of Maine's Harold Alfond Wind and Wave (W2) facility. System dynamics and turbine characteristics are measured to determine global performance and assess the effect of the control strategies employed. NREL's reference open-source controller (ROSCO) is used for active blade pitch control and hull structural control is examined through the use of tuned mass dampers (TMD's) tuned to the systems pitch and tower-bending natural frequency. The naming convention of the load cases considered are described in the data details section. Detailed properties on the modeled system are found in the following reference: Lenfest E., Floating Offshore-wind Controls Advanced Laboratory (FOCAL) Experimental Program - Campaign IV: 1:70 Model-scale Testing of the IEA-Wind 15MW Reference Turbine and the VolturnUS-S Platform. UMaine ASCC Report Number 23-57-1183.

17 WIND ENERGY↗

Tethered aerothermodynamic research for hypersonic waveriders

This paper describes the concept of a space-tethered atmospheric system, a hybrid craft consisting of an orbiting spacecraft and a downward-deployed aerodynamically-configured satellite. Such a system could conduct both hypersonic aerothermodynamics research and atmospheric science research in the outer atmosphere (about 150-90 km). Descriptions of specific space-tethered atmospheric systems, scheduled tether flight validation experiments, and a development strategy for a three-phased aerothermodynamics research capability culminating in a 'flying wind tunnel' are provided.

Anderson, John L.↗

The Chesapeake Lighthouse and Aircraft Measurements for Satellites (CLAMS) Experiment

NASA has developed an Earth Observing System (EOS) consisting of a series of satellites designed to study global change from space. The EOS flagship is the EOS TERRA satellite, launched in December 1999, equipped with five unique sensors to monitor and study the Earth s heat budget and many of the key controlling variables governing the Earth's climate system. CLAMS, the Chesapeake Lighthouse and Aircraft Measurements for Satellites field campaign was conducted from NASA Wallops Flight Facility and successfully executed over the middle Atlantic eastern seaboard from July 10 August 2, 2001. CLAMS is primarily a shortwave closure experiment designed to validate and improve EOS TERRA satellite data products being derived from three sensors: CERES (Clouds and Earth's Radiant Energy System), MISR (Multi-angle Imaging Spectro-Radiometer) and MODIS (MODerate Resolution Imaging Spectroradiometer). CLAMS is jointly sponsored by the CERES, MISR and MODIS instrument teams and the NASA GEWEX Global Aerosol Climatology Project (GACP). CLAMS primary objectives are to validate satellite-based retrievals of aerosol properties and vertical profiles of radiative flux, temperature and water vapor. Central to CLAMS measurement strategy is the Chesapeake Lighthouse, a stable sea platform located in the Atlantic Ocean, 13 miles east of Virginia Beach near the mouth of the Chesapeake Bay and the site of an ongoing CERES Ocean Validation Experiment (COVE). Six research aircraft were deployed to make detailed measurements of the atmosphere and ocean surface in the vicinity of COVE, over the surrounding ocean, over nearby NOAA buoys and over a few land sites. The measurements are used to validate and provide ground truth for simultaneous products being derived from TERRA data, a key step toward an improved understanding and ability to predict changes in the Earth's climate. One of the two CERES instruments on-board TERRA was programmed for Rotating Azimuth Plane Scans (RAPS) during CLAMS, increasing the CERES coverage over COVE by a factor of 10. Nine coordinated aircraft missions and numerous additional sorties were flown under a variety of atmospheric conditions and aerosol loadings. On one golden day, July 17, all six aircraft flew coordinated patterns, vertically stacked between 100 ft and 65,000 ft over the COVE site as the TERRA satellite orbited overhead. A summary of CLAMS measurement campaign and a description of the platforms and measurements is given.

Smith, William L., Jr.↗

Electric Power System Technology Options for Lunar Surface Missions

In 2004, the President announced a 'Vision for Space Exploration' that is bold and forward-thinking, yet practical and responsible. The vision explores answers to longstanding questions of importance to science and society and will develop revolutionary technologies and capabilities for the future, while maintaining good stewardship of taxpayer dollars. One crucial technology area enabling all space exploration is electric power systems. In this paper, the author evaluates surface power technology options in order to identify leading candidate technologies that will accomplish lunar design reference mission three (LDRM-3). LDRM-3 mission consists of multiple, 90-day missions to the lunar South Pole with 4-person crews starting in the year 2020. Top-level power requirements included a nominal 50 kW continuous habitat power over a 5-year lifetime with back-up or redundant emergency power provisions and a nominal 2-kW, 2-person unpressurized rover. To help direct NASA's technology investment strategy, this lunar surface power technology evaluation assessed many figures of merit including: current technology readiness levels (TRLs), potential to advance to TRL 6 by 2014, effectiveness of the technology to meet the mission requirements in the specified time, mass, stowed volume, deployed area, complexity, required special ground facilities, safety, reliability/redundancy, strength of industrial base, applicability to other LDRM-3 elements, extensibility to Mars missions, costs, and risks. For the 50-kW habitat module, dozens of nuclear, radioisotope and solar power technologies were down-selected to a nuclear fission heat source with Brayton, Stirling or thermoelectric power conversion options. Preferred energy storage technologies included lithium-ion battery and Proton Exchange Membrane (PEM) Regenerative Fuel Cells (RFC). Several AC and DC power management and distribution architectures and component technologies were defined consistent with the preferred habitat power generation technology option and the overall lunar surface mission. For rover power, more than 20 technology options were down-selected to radioisotope Stirling, liquid lithium-ion battery, PEM RFC, or primary fuel cell options. The author discusses various conclusions that can be drawn from the findings of this surface power technologies evaluation.

Kerslake, Thomas W.↗

1:70-Scale Model Testing of the Reference OpenSource Controller (ROSCO) on the IEA-Wind 15MW Reference Wind Turbine Including Floating Feedback: Preprint

This paper presents results from the Floating Offshore-wind Controls Advanced Laboratory (FOCAL) Experimental campaign performed at the University of Maine's (UMaine's) Harold Alfond Wind/Wave Ocean Engineering Laboratory (W2). The project involves four Froude-scaled test campaigns considering the International Energy Agency (IEA) Wind 15MW Reference Wind Turbine deployed on the VolturnUS-S semi-submersible platform with tuned-mass damper (TMD) elements in the hull. The turbine employs real-time rotor torque and blade pitch control through the Reference OpenSource Controller (ROSCO), including the additional control strategies of ROSCO's thrust peak shaving and a floating feedback control loop. Results with the floating feedback control are considered in this paper and show a significant reduction in platform pitch motion and loads around the platform pitch natural frequency with minimal negative impact of rotor power quality.

controls↗

Liquid Alkaline Water Electrolyzers: Comparing Performance across Design, Operation, and End-of-Life Scenarios

Liquid alkaline water electrolysis (LAWE) is a demonstrated technology for hydrogen production, yet a comprehensive life cycle assessment (LCA) of their deployment is lacking. Research leading to improvements to the core component, the electrochemical stack, along with auxiliary system materials and dynamic operation of stacks from variable electricity supply offers new data that allows for detailed modeling and evaluation. Here, we present an LCA of two facility designs based on the current state-of-the-art stack and an advanced stack with zero-gap between electrodes, and capture dynamic electricity use from solar, wind, and hybrid sources and stack recycling strategies. We present life cycle impact factors characterizing the production of 1 kg of hydrogen across 12 environmental, human health, and resource impact categories (TRACI and ReCiPe) in the contiguous United States. As expected, the source of electricity will drive impacts (e.g., 83-94% of carbon intensity); however, we find that operating using wind electricity can lower hydrogen leakage and the overall carbon intensity (1.03 kgCO 2 e/kgH 2 ) relative to solar electricity (2.57 kgCO 2 e/kgH 2 ) at matched 1:1 capacity between LAWE and the electricity source. The deployment of the advanced design and stack recycling lowers impacts across all life cycle stages. We highlight opportunities to further reduce potential impacts, including the balance of plant materials and operation cycles associated with the use of variable wind and solar electricity that result in hydrogen leakage.

08 HYDROGEN↗

Onboard Data Analysis for the Planetary Instrument for X-Ray Lithography

Imaging spectrometers are invaluable instruments for robotic science exploration, enabling quantitative maps of physical and chemical properties at high spatial resolution. This is particularly valuable in remote missions to other planetary bodies like Mars. The PIXL instrument on the Mars 2020 rover will deploy an arm-mounted X-Ray fluorescence spectrometer to map chemical composition at sub-millimeter scales. Its high resolution places dramatic new demands on instrument placement accuracy and measurement time. We address these challenges using novel on board data analysis strategies inspired by FRC science autonomy research.

Thompson, David R.↗

EVs@Scale Next-Gen Profiles - Fleet Utilization 2023

As U.S. fleet operators begin transitioning to electric vehicles (EVs), critical questions arise regarding how to manage this shift without disrupting fleet operations or placing undue stress on the electric grid. A major challenge for fleets is maintaining effective operational schedules while accommodating charging requirements, particularly with high-power charging (HPC) infrastructure, which presents grid stability concerns for utilities. Proposed solutions such as charging substations, megawatt charging systems (MCS), and smart charge management systems (SCMS) offer potential pathways forward, but their effectiveness depends on alignment with real-world fleet behavior and operational constraints. This report investigates the charging and utilization behavior of EV and EVSE fleets actively employing HPC technologies by conducting detailed case study analyses based on telematics data. A suite of predefined metrics—covering charging, routing, and other operational behaviors—is developed to evaluate the impact of fleet activities on grid infrastructure and identify opportunities for optimization. Results highlight variations in charging behavior across fleets, such as weekday versus weekend usage, diurnal charging trends, and the role of operational predictability in enabling SCMS effectiveness. While SCMS can help lower costs and improve energy efficiency for fleets with stable schedules, they may be insufficient for fleets with highly variable or long-haul operations, which may require more robust solutions like MCS. Visualization of aggregated hourly energy metrics reveals that while fleet behaviors are diverse, there are common temporal patterns that could inform infrastructure planning and energy management. These insights emphasize the need for fleet-specific charging strategies that minimize grid impact while supporting reliable fleet operations. Additionally, the report underscores the broader economic stakes of electrification, particularly in high-value markets such as freight, where misaligned transitions could stall EV adoption. By examining current EV and EVSE fleet deployments using predetermined standardized metrics, this study offers a foundation for developing technologies and operational frameworks that support scalable, grid-compatible electrification across a variety of fleet types while establishing a baseline understanding of operational behaviors. In doing so, we aim to ensure that future charging solutions reflect actual fleet needs and grid constraints—an essential step toward maintaining operational continuity and achieving a successful transition to electric fleet operations.

Charging↗

RESCue Model (RESCue Experiment and Model) [SWR-24-84]

The Renewable Energy and Storage Cybersecurity Research (RESCue) project is a collaborative effort aimed at securing the rapidly growing deployment of transmission-connected hybrid renewable energy systems, consisting of a combination of wind, solar, and/or energy storage equipment, against escalating cyber threats. This project brings together major original equipment manufacturers (OEMs) of wind, solar, and energy storage, along with major asset owners and DOE National Laboratories, to collectively identify cyber threats, assess risks, and develop robust cybersecurity strategies and solutions. The development of hybrid reference architectures has provided comprehensive blueprints for the secure design and integration of hybrid renewable energy systems, accounting for their unique characteristics and interdependencies. Additionally, NREL has created a cyber-resilient design framework that integrates cybersecurity considerations from the start of the system lifecycle, ensuring security is "baked in" from the initial design phase. The research thrusts for the project included (i) development of hybrid reference architectures and (ii) a cyber-resilient design framework for hybrid energy systems. The reference architectures has provided comprehensive blueprints for the secure design and integration of hybrid renewable energy systems, accounting for their unique characteristics and interdependencies. Additionally, NREL has created a cyber-resilient design framework that integrates cybersecurity considerations from the start of the system lifecycle, ensuring security is "baked in" from the initial design phase. A demonstration experiment was developed for one of the architectures using NREL's Cyber Range resources. This experiment configuration, deployable using open-source tools, is provided here in this repository. Additional models were developed for the wind and solar architectures as well, however the configurations for only the Energy Storage scenario are provided here: https://www.nrel.gov/docs/fy24osti/89921.pdf

Hasandka, Adarsh↗

Lean-Stratified Combustion System with Miller Cycle for Downsized Boosted Application - Part 2

Automotive manufacturers relentlessly explore engine technology combinations to achieve reduced fuel consumption under continued regulatory, societal and economic pressures. For example, technologies enabling advanced combustion modes, increased expansion to effective compression ratio and reduced parasitics continue to be developed and integrated within conventional and hybrid propulsion strategies across the industry. Here, a high-efficiency gasoline engine capable for use in conventional or hybrid electric vehicle platforms is highly desirable. This paper is the second of two papers describing the multi-cylinder integration of a technology package combining lean-stratified combustion with Miller cycle for downsized boosted applications. The first paper describes the design, analysis and single-cylinder testing conducted to down-select the combustion system deployed to the multi-cylinder engine. This paper defines a light-duty engine package capable of achieving a 35% fuel economy improvement at US Tier 3 emission standards over a naturally aspirated stoichiometric baseline vehicle. A multi-mode combustion system was developed enabling highly efficient lean-stratified operation at light-load and stoichiometric Miller-cycle operation at mid- to high-loads. A central direct-injection four-valve layout was designed with high-tumble ports and a bowl-in-piston capable of stable operation under highly dilute mixtures when properly matched to fuel spray characteristics, injection strategy, and a high-energy ignition system. Boost system layout and base engine architecture were selected to minimize parasitics and maximize after treatment effectiveness. A multi-cylinder engine was developed and calibrated over a steady-state map. Results fed vehicle simulations over the EPA city and highway test cycles to predict the fuel economy improvement and tailpipe emissions potential. Fuel economy improvements over the baseline vehicle were projected at 42% and 39% for active-urea and passive-ammonia SCR after treatment systems respectively. Controls complexity to achieve regulatory compliance and the cost of the lean after treatment system were identified as the primary challenges to commercial viability.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Decarbonization of the Electric Power Sector and Implications for Low-Cost Hydrogen Production from Water Electrolysis

Increasing development of wind and solar generation in the power sector can create economic opportunities for the deployment of water electrolyzers that produce hydrogen. Temporal variation in the marginal cost of energy in future decarbonized grids can make it favorable for electrolyzers to dispatchably ramp hydrogen production up and down in response to low- and high-cost times. Using this strategy, low-cost hydrogen production is enabled by electrolyzers that are low-capital cost and tolerant to frequent on/off cycling. Ramping down hydrogen production to a designated turndown ratio can avoid performance degradation caused by on/off cycling by not shutting the electrolyzer completely off. This comes with a slight cost penalty which can be minimized if the turndown ratio is low (i.e., the system ramps down hydrogen production to close to zero). These results suggest that electrolyzers integrated into future power systems are likely to benefit from the ability to ramp operation up and down quickly and operate in a standby mode. This analysis forms a basis for comparative tradeoffs between electrolyzer capital cost, operating strategy, and system durability and demonstrates the importance of considering all three factors in technoeconomic analysis.

capital cost↗