Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “degradation rate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Quantifying Leak Rates and Vacuum Impact on Granular Soil Column Pneumatic Seal

Introduction: All In-Situ Resource Utilization (ISRU) regolith reactor systems that aim to extract gases or vapors must maintain a seal along the flow path of the regolith from the inlet hopper to where extracted gases or vapors are generated. Using a column of regolith at the inlet has been proposed as an alternative to systems using series of mechanical valves to reduce mass and complexity. Preliminary investigations into the use of regolith itself as a barrier to escaping fluids have been conducted, which this research seeks to expand upon. Different vertical regolith simulant plug diameters and heights were tested under vacuum with dry nitrogen to observe leak rates and approximate steady state pressure gradient equilibria. The effect of absolute ambient pressure was also studied by repeating tests at incremental pressures ranging from 10e-5 Torr up to 1 atm to corroborate ambient bench tests from previous work. The impact of regolith dynamics was addressed to emulate continuous-feed regolith reaction processes by measuring leak rates through continuously draining simulant columns. OB-1 lunar highlands regolith simulant was used. Experimental Setup: Regolith simulant columns were constructed using a motorized butterfly valve separating upper acrylic tubes of various diameters from a larger, lower aluminum pipe plenum (See Figure 1). The butterfly valve was cracked open such that gas could freely pass through whereas regolith would bridge and stay suspended as a cohesive plug above in the acrylic portion. These assemblies were loaded into a vacuum chamber, and a compressed dry nitrogen line was routed into the lower plenum. Pressure transducers measured the absolute pressure of the lower plenum, which was compared to absolute chamber pressure to monitor the pressure gradient across the regolith simulant. A precision mass flow controller enabled fine control of plenum pressure. The plenum pressure was quasi-statically increased to set points informed by previous work [1] before shutting off the gas supply to allow the now pressurized gas volume to dissipate through the simulant into the chamber in what was referred to as a ‘leak test.’ In a separate set of tests, the pressure was allowed to quasi-statically build until visual disturbances in the soil were observed via remote camera feeds. Initial leak rate tests were repeated on the disturbed soil to observe changes in leak rates between initial as-poured and post-bubbling soil conditions. This test schedule was applied to simulant columns of three different diameters (approximately 2, 4, and 6 inches) as well as two different heights (around 8 and 16 inches) and was repeated at least three times for each configuration. Plenums were also pressurized while the butterfly valves were opened slightly further to facilitate slow, controlled, constant flowrate draining of the simulant to observe the impact that continuous-feed systems might have on leak rate through the regolith column. Finally, the regolith columns were reset and refilled and static leak rate tests were repeated approximately every decade in ambient pressure from 10e-5 Torr up to ambient conditions to observe the impact of transitioning out of the molecular flow regime on regolith column seal performance. Analysis: Trends with respect to each factor examined were constructed and reported alongside commentary on the most likely responsible physical phenomena. Confidence intervals were applied to the predictive findings of the data by quantifying instrumentation error and accounting for probabilistic impacts of curve fitting the generic exponential function onto pressure decay data. The leak rate is assumed directly proportional to the exponential term coefficient, while the steady-state static pressure gradient is assumed to be the asymptotic limit of each curve fit. Finally, a generic model developed by Ogino et al. [2] and later tuned for ambient testing was re-tuned using vacuum data to estimate leak rates on the lunar surface. Results: Pressure decay rates decreased up to 27-fold under vacuum when compared to ambient pressure, as shown in Figure 2. Simulant column diameter was found to exponentially correlate to both regolith column leak rate and steady-state equilibrium pressure delta. Height was found to be linearly related to leak rate –doubling the regolith column height consistently yielded around a 40% reduction in leak rate. Dynamic regolith draining was found to slightly increase leak rate, although to a lower degree than expected. Conclusion: Because of the transition into molecular gas flow through regolith, vacuum testing is required to properly estimate performance. Regolith columns should be designed as narrow as possible to avoid bridging and minimize leak rate, and as tall as is feasible to both further reduce leak rate and to help prevent bubbling, which has been shown to degrade the quality of the regolith seal. Disrupted soil was found to exhibit higher leak rates than pristine, as-poured soil, indicating the need to consider the impact of recovery from depressurization events. Regolith columns appear equally feasible for both dosed and continuous-feed reactors.

ISRU↗

Performance measurements for a laboratory-simulated 30/20 GHz communication satellite transponder

NASA has developed a digital satellite communications system simulator and test bed facility, known as the SITE (System Integratrion, Test and Evaluation) Project. The purpose of the facility is to evaluate satellite system components, develop and verify system concepts, and perform satellite system experiments. A recently completed set of experiments measured the performance of the 30/20 GHz satellite transponder portion of the system in terms of RF parameters and high rate digital data transmission. The results of these tests indicate the quality of data transmission which can be obtained under various transponder operating conditions, as well as the relative effects of degraded RF performance on the bit-error rate (BER) of transmitted data.

Kerczewski, Robert J.↗

Optimal filtering and generation of entangled photons for quantum applications in the presence of noise

Filtering is commonly used in quantum optics to reject noise photons, and also to enable interference between independent photons. However, filtering the joint spectrum of photon pairs can reduce the inherent coincidence probability or loss-independent heralding efficiency. Here we investigate filtering for multiphoton applications based on entanglement and interference (e.g., quantum teleportation). We multiplex C-band entangled photons and C-band classical communications into the same long-distance fibers, which enables scalable low-loss quantum networking but requires filtering of spontaneous Raman scattering noise from classical light. Using tunable-bandwidth filters, low-jitter detectors, and polarization filters, we distribute wavelength-degenerate time-bin entangled photons in the C band (1536.5 nm) over 25 km/25 km standard fibers (50 km) each carrying 10 Gbit/s C-band classical data signals. Narrow filtering enables milliwatt-level C-band power, which exceeds the power achieved by comparable studies by roughly an order of magnitude and could feasibly support terabit per second classical rates. We evaluate how performance depends on pump and filter bandwidths, multipair emission, filter shapes, loss, phase matching, and how quantum information is measured. We find a trade-off between reducing noise impact and increasing single-mode purity, and discuss mitigation methods toward optimal multiphoton applications. Importantly, these results apply to noise in free space and in quantum devices (sources, frequency converters, switches, detectors, etc.) and provide insight into filter-induced degradation of single-photon purity and rates even in noise-free environments.

Thomas, Jordan M. [Fermilab; Northwestern U.]↗

Radiolytic evaluation of a new technetium redox control reagent for advanced used nuclear fuel separations

Technetium is a problematic radioisotope for used nuclear fuel (UNF) and subsequent waste management owing to its high environmental mobility and coextraction in reprocessing technologies as the pertechnetate anion (TcO 4 - ). Consequently, several strategies are under development to control the transport of this radioisotope. A proposed approach is to use diaminoguanidine (DAG) for TcO 4 - and transuranic ion redox control. Although the initial DAG molecule is ultimately consumed in the redox process, its susceptibility to radiolysis is currently unknown under envisioned UNF reprocessing conditions, which is a critical knowledge gap for evaluating its overall suitability for this role. To this end, we report the impacts of steady-state gamma irradiation on the rate of DAG radiolysis in water, aqueous 2.0 M nitric acid (HNO 3 ), and in a biphasic solvent system composed of aqueous 2.0 M HNO 3 in contact with 1.5 M N,N-di-(2-ethylhexyl)isobutyramide (DEHiBA) dissolved in n-dodecane. In addition, we report chemical kinetics for the reaction of DAG with key transients arising from electron pulse radiolysis, specifically the hydrated electron (e aq - ), hydrogen atom (H ˙ ), and hydroxyl ( ˙ OH) and nitrate (NO 3 ˙ ) radicals. The DAG molecule exhibited significant reactivity with the ˙ OH and NO 3 ˙ radicals, indicating that oxidation would be the predominant degradation pathway in radiation environments. This is consistent with its role as a reducing agent. Steady-state gamma irradiations demonstrated that DAG is readily degraded within a few hundred kilogray, the rate of which was found to increase upon going from water to HNO 3 containing solutions and solvents systems. This was attributed to a thermal reaction between DAG and the predominant HNO 3 radiolysis product, nitrous acid (HNO 2 ), k(DAG + HNO 2 ) = 5480 ± 85 M -1 s -1 . Although no evidence was found for the radiolysis of DAG altering the radiation chemistry of the contacted DEHiBA/n-dodecane phase in the investigated biphasic system, the utility of DAG as a redox control reagent will likely be limited by significant competition with its degradation by HNO 2 .

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Quantifying the impact of operating temperature on cracking in battery electrodes, using super-resolution of microscopy images and stereology

There are numerous factors that can have an impact on the degradation behavior of batteries, such as the number of recharge cycles or the charge rate. Here, we investigate the influence of operating temperature on the structural degradation of the microstructure in lithium-ion positive electrodes. For that purpose, the microstructure is characterized for cathodes which have been cycled for 200 cycles under 6C (10-minute) charging at different operating temperatures, namely, 20°C, 30°C, 40°C, and 50°C. For each operating condition scanning electron microscopy (SEM) images of cross-sectioned Li x Ni 0.5 Mn 0.3 Co 0.2 O 2 (NMC532) electrodes have been analyzed, to determine structural descriptors such as global particle porosity, crack size/length/width distribution, and porosity and specific surface area distribution of individual particles. Additionally, a stereological method has been deployed to investigate the local particle porosity as a function of distance to the particle center. Results show that particle porosity increases with increasing cycling temperature. Particle porosity is greatest at the particle center and decreases along the particle radius to the exterior. Particle surface area is similar across the four cycling-temperature aging conditions.

25 ENERGY STORAGE↗

Enhanced Low Dose Rate Sensitivity at Ultra-Low Dose Rates

We have presented results of ultra-low dose rate irradiations (< or = 10 mrad(Si)/s) for a variety of radiation hardened and commercial linear bipolar devices. We observed low dose rate enhancement factors exceeding 1.5 in several parts. The worst case of dose rate enhancement resulted in functional failures, which occurred after 10 and 60 krad(Si), for devices irradiated at 0.5 and 10 mrad(Si)/s, respectively. Devices fabricated with radiation hardened processes and designs also displayed dose rate enhancement at below 10 mrad(Si)/s. Furthermore, the data indicated that these devices have not reached the damage saturation point. Therefore the degradation will likely continue to increase with increasing total dose, and the low dose rate enhancement will further magnify. The cases presented here, in addition to previous examples, illustrate the significance and pervasiveness of low dose rate enhancement at dose rates lower than 10 mrad(Si). These results present further challenges for radiation hardness assurance of bipolar linear circuits, and raise the question of whether the current standard test dose rate is conservative enough to bound degradations due to ELDRS.

Chen, Dakai↗

A Materials Compatibility and Thermal Stability Analysis of Common Hydrocarbon Fuels

A materials compatibility and thermal stability investigation was conducted using five common liquid hydrocarbon fuels and two structural materials. The tests were performed at the NASA Glenn Research Center Heated Tube Facility under environmental conditions similar to those encountered in regeneratively cooled rocket engines. Scanning-electron microscopic analysis in conjunction with energy dispersive spectroscopy (EDS) was utilized to characterize the condition of the tube inner wall surface and any carbon deposition or corrosion that was formed during selected runs. Results show that the carbon deposition process in stainless steel tubes was relatively insensitive to fuel type or test condition. The deposition rates were comparable for all fuels and none of the stainless steel test pieces showed any signs of corrosion. For tests conducted with copper tubing, the sulfur content of the fuel had a significant impact on both the condition of the tube wall and carbon deposition rates. Carbon deposition rates for the lowest sulfur fuels (2 ppm) were slightly higher than those recorded in the stainless steel tubes with no corrosion observed on the inner wall surface. For slightly higher sulfur content (25 ppm) fuels, nodules that intruded into the flow area were observed to form on the inner wall surface. These nodules induced moderate tube pressure drop increases. The highest sulfur content fuels (400 ppm) produced extensive wall pitting and dendritic copper sulfide growth that was continuous along the entire tube wall surface. The result of this tube degradation was the inability to maintain flow rate due to rapidly increasing test section pressure drops. Accompanying this corrosion were carbon deposition rates an order of magnitude greater than those observed in comparable stainless steel tests. The results of this investigation indicate that trace impurities in fuels (i.e. sulfur) can significantly impact the carbon deposition process and produce unacceptable corrosion levels in copper based structural materials.

Meyer, M. L.↗

Photovoltaic module antireflection coating degradation survey using color microscopy and spectral reflectance

Abstract Commercial antireflective coatings (ARCs) on photovoltaic (PV) module glass can improve module power by 2.5%–3.0%, but their long‐term field performance requires additional study. In this paper, we investigate ARC performance on fielded modules using two nondestructive techniques: reflectance spectroscopy and RGB microscopy, finding a large variation in coating durability and performance. For new coatings, the fleet average nominal power enhancement is 2.8%. This power enhancement is observed to degrade at approximately −0.05%/year absolute over the first 8 years of fielding in arrays that are not regularly cleaned. Interferometry and imaging results imply that coating loss for these modules is due to slow chemical thinning of the initial 125 nm thick coating by 1.4 to 5.0 nm/year. Due to the physics of interference coatings, the performance loss is projected to accelerate as the coating is further thinned, resulting in a coating lifetime (time to 80% of initial performance) of 7.5 to 25 years. At the higher 5.0 nm/year coating loss rates, we estimate that −0.14%/year power degradation of the module can be attributed solely to ARC degradation over the first 20 years. Extreme coating loss is observed on some modules where after 8 years fielding, the coating can be completely removed with a single wet wipe with a lens tissue. A case study is also presented comparing ARC and noncoated modules installed at a single site in 2013. We find that the ARC modules have a 2.6% higher soiling power loss than the noncoated modules; this exceeds the ARC power enhancement of 2.4% and leads to the surprising conclusion that the ARC lowers production for modules in this location due to increased soiling. These results demonstrate that RGB microscopy is a powerful, field‐capable, and quantitative characterization technique for assessing degradation of PV module ARCs.

Karin, Todd↗

Corrosion rates measured under potentiostatic conditions to represent performance of a cermet nuclear waste form

Electrochemical tests were conducted to assess the corrosion performance of a developmental multiphase cermet nuclear waste form in different conditions. Corrosion currents were monitored as the surface equilibrated in an acidic brine solution during potentiostatic tests at different imposed potentials. Electrochemical impedance spectroscopy was used to quantify differences in the electrical properties of surfaces stabilised at different potentials. The passivating oxides that will stabilise the surface under disposal conditions are formed and maintained during testing. The measured corrosion currents were two orders of magnitude lower for passivated surfaces than for polished surfaces over a wide range of redox conditions. The electrochemical results were correlated with microscopic analyses of the corroded surfaces and physical models of the surface passivation and degradation processes are proposed. The measured corrosion rates are suitable for the long-term performance modeling of cermet nuclear waste forms.

Gattu, V. K.↗

The Work of Mechanical Degradation in Elongating Polymer Melts

Molecular dynamics simulations are used to study the mechanical degradation of well-entangled polymer melts during uniaxial extensional flow. Simulations measure the transient rise in extensional stresses and relate them to the molecular alignment and scission of chain backbones. Intermolecular entanglements couple chain scission in space and time, making degradation sensitive to deformation history and strain rate in ways not displayed by dilute polymer solutions. The rate of chain scission is nonmonotonic and peaks at strains corresponding to the maximum extensibility of entanglement segments but prior to the full extension of chain backbones. We measure a specific work per scission event w* and decompose it into separate contributions associated with chain alignment, chemical bond breaking, and scission-induced plasticity. We find chain scission in melts requires activating plastic dissipation that is multiple orders of magnitude larger than the chemical work required to break a covalent backbone bond. Our findings underscore the critical need to consider bulk polymer mechanics and rheology in designing efficient mechanical degradation and mechanochemical processes.

36 MATERIALS SCIENCE↗

High Dose Rate Irradiations of Enduray Vision System for Nuclear Inspections

Higher radiation-hardened video cameras are needed in the operation and remote handling of equipment in nuclear reactor inspection and refueling applications. Vega Wave Systems, Inc. has developed a radiation-hardened vision system for nuclear energy applications. This vision system has been developed under several small business innovative research programs (SBIRs) from the U.S. Department of Energy, and the previous GAIN voucher program at Argonne National Laboratory (ANL) was successful in demonstrating that a prototype of the camera is radiation-hard up to at least 525 kGy (5.25 × 106 rad, Si equivalent) at dose rates of 10 kGy/hr with no measurable degradation in image quality and no measurable radiation-induced noise (RIN). Vega Wave Systems has developed a new version of the camera with more than 3X the resolution using a new design and new components, and this new design requires radiation-hardness qualification for marketplace acceptance. The program described in this report provided high radiation-hardness testing of this redesigned high-resolution vision system using the Argonne Low-Energy Accelerator Facility (LEAF). This report presents the results of irradiation tests performed on Vega Wave System’s redesigned high resolution vision system at a dose rate of 9.3 kGy/hr and up to total doses of 1823 kGy. This was an accumulation of 197 hours of irradiation. The results were excellent, providing proof of the redesigned high-resolution vision system’s immunity to high levels of radiation.

42 ENGINEERING↗

Impact of surface coating on electrochemical and thermal behaviors of a Li-rich Li 1.2 Ni 0.16 Mn 0.56 Co 0.08 O 2 cathode

Lithium-rich layered oxide materials are considered as potential cathode materials for future high-performance lithium-ion batteries (LIBs) owing to their high operating voltage and relatively high specific capacity. However, perceptible issues such as poor rate performance, poor capacity retention, and voltage degradation during cycling need to be improved before the successful commercialization of the material. In this report, zirconia coated Li 1.2 Ni 0.16 Mn 0.56 Co 0.08 O 2 2 = 1.0, 1.5 and 2.0 wt%) materials are synthesized using a sol–gel assisted ball milling approach. A comparison of structural, morphological and electrochemical properties is examined to elucidate the promising role of ZrO 2 coating on the performance of the NMC cathode. A uniform and homogeneous ZrO 2 coating is observed on the surface of NMC particles as evident by TEM elemental mapping images. The ZrO 2 coated NMCs exhibit significantly improved electrochemical performance at a higher C-rate as compared to pristine material. 1.5% ZrO 2 coated NMC demonstrates better cycling stability (95% capacity retention) than pristine NMC (77% capacity retention) after 50 cycles. All ZrO 2 coated NMC materials demonstrated improved thermal stability compared to pristine material. The difference in onset temperature of 2 wt% ZrO 2 coated and pristine NMC is 20 °C. The improved electrochemical performance of ZrO 2 coated NMC can be attributed to the stabilization of its surface structure due to the presence of ZrO 2 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Pathways towards managing cost and degradation risk of fast charging cells with electrical and thermal controls

The charging rate of Li-ion batteries is limited by the risks of lithium plating and thermal damage, both of which negatively affect lifetime of the batteries. This work analyzes how to minimize charge time and manage the risk of degradation using both electrical and thermal controls. To accomplish this, an electrochemical-thermal model is developed to introduce a constant-risk fast charging protocol which maximizes the charging current while maintaining the cell within pre-defined design limits selected to minimize the risk of degradation. Results indicate 80%-charging of a typical NMC/graphite cell can be achieved within 10 minutes with a cell cost under $100 kW –1 h –1 (corresponding to an 80 μm thick anode) when charged at moderate allowable risks of degradation. Here, we also demonstrate how stretching the allowable risk (i.e., higher temperatures, larger C-rates, and lower anode potential limits) allows affordable design of fast charging cells.

25 ENERGY STORAGE↗

Perspective: Performance Loss Rate in Photovoltaic Systems

Photovoltaic systems may underperform expectations for several reasons, including inaccurate initial estimates, suboptimal operations and maintenance, or component degradation. Accurate assessment of these loss factors aids in addressing root causes of underperformance and in realizing accurate expectations and models. The performance loss rate (PLR) is a commonly cited high‐level metric for the change in system output over time, but there is no precise, standard definition. Herein, an annualized definition of PLR that is inclusive of all loss factors and that can capture nonlinear changes to performance over time is proposed. The importance of distinguishing between recoverable and nonrecoverable losses which underly PLR is highlighted.

14 SOLAR ENERGY↗

Forest Cover Associated with Improved Child Health and Nutrition: Evidence from the Malawi Demographic and Health Survey and Satellite Data

Healthy forests provide human communities with a host of important ecosystem services, including the provision of food, clean water, fuel, and natural medicines. Yet globally, about 13 million hectares of forests are lost every year, with the biggest losses in Africa and South America. As biodiversity loss and ecosystem degradation due to deforestation continue at unprecedented rates, with concomitant loss of ecosystem services, impacts on human health remain poorly understood. Here, we use data from the 2010 Malawi Demographic and Health Survey, linked with satellite remote sensing data on forest cover, to explore and better understand this relationship. Our analysis finds that forest cover is associated with improved health and nutrition outcomes among children in Malawi. Children living in areas with net forest cover loss between 2000 and 2010 were 19% less likely to have a diverse diet and 29% less likely to consume vitamin A-rich foods than children living in areas with no net change in forest cover. Conversely, children living in communities with higher percentages of forest cover were more likely to consume vitamin A-rich foods and less likely to experience diarrhea. Net gain in forest cover over the 10-year period was associated with a 34% decrease in the odds of children experiencing diarrhea (P5.002). Given that our analysis relied on observational data and that there were potential unknown factors for which we could not account, these preliminary findings demonstrate only associations, not causal relationships, between forest cover and child health and nutrition outcomes. However, the findings raise concerns about the potential short- and long-term impacts of ongoing deforestation and ecosystem degradation on community health in Malawi, and they suggest that preventing forest loss and maintaining the ecosystems services of forests are important factors in improving human health and nutrition outcomes.

malawi↗

Jitter Controller Software

Sinusoidal jitter is produced by simply modulating a clock frequency sinusoidally with a given frequency and amplitude. But this can be expressed as phase jitter, frequency jitter, or cycle-to-cycle jitter, rms or peak, absolute units, or normalized to the base clock frequency. Jitter using other waveforms requires calculating and downloading these waveforms to an arbitrary waveform generator, and helping the user manage relationships among phase jitter crest factor, frequency jitter crest factor, and cycle-to-cycle jitter (CCJ) crest factor. Software was developed for managing these relationships, automatically configuring the generator, and saving test results documentation. Tighter management of clock jitter and jitter sensitivity is required by new codes that further extend the already high performance of space communication links, completely correcting symbol error rates higher than 10 percent, and therefore typically requiring demodulation and symbol synchronization hardware to operating at signal-to-noise ratios of less than one. To accomplish this, greater demands are also made on transmitter performance, and measurement techniques are needed to confirm performance. It was discovered early that sinusoidal jitter can be stepped on a grid such that one can connect points by constant phase jitter, constant frequency jitter, or constant cycle-cycle jitter. The tool automates adherence to a grid while also allowing adjustments off-grid. Also, the jitter can be set by the user on any dimension and the others are calculated. The calculations are all recorded, allowing the data to be rapidly plotted or re-plotted against different interpretations just by changing pointers to columns. A key advantage is taking data on a carefully controlled grid, which allowed a single data set to be post-analyzed many different ways. Another innovation was building a software tool to provide very tight coupling between the generator and the recorded data product, and the operator's worksheet. Together, these allowed the operator to sweep the jitter stimulus quickly along any of three dimensions and focus on the response of the system under test (response was jitter transfer ratio, or performance degradation to the symbol or codeword error rate). Additionally, managing multi-tone and noise waveforms automated a tedious manual process, and provided almost instantaneous decision- making control over test flow. The code was written in LabVIEW, and calls Agilent instrument drivers to write to the generator hardware.

Lansdowne, Chatwin↗

Study of communications data compression methods

A simple monochrome conditional replenishment system was extended to higher compression and to higher motion levels, by incorporating spatially adaptive quantizers and field repeating. Conditional replenishment combines intraframe and interframe compression, and both areas are investigated. The gain of conditional replenishment depends on the fraction of the image changing, since only changed parts of the image need to be transmitted. If the transmission rate is set so that only one fourth of the image can be transmitted in each field, greater change fractions will overload the system. A computer simulation was prepared which incorporated (1) field repeat of changes, (2) a variable change threshold, (3) frame repeat for high change, and (4) two mode, variable rate Hadamard intraframe quantizers. The field repeat gives 2:1 compression in moving areas without noticeable degradation. Variable change threshold allows some flexibility in dealing with varying change rates, but the threshold variation must be limited for acceptable performance.

Jones, H. W.↗

Detection of signals by the digital integrate-and-dump filter with offset sampling

The Integrate and Dump Filter (IDF) is used as a matched filter for the detection of signals in additive white Gaussian noise. The performance of the digital integrate and dump filter is evaluated. The case considered is when symbol times are known and the sampling clock is free running at a constant rate, i.e., the sampling clock is not phase locked to the symbol clock. Degradations in the output signal to noise ratio of the digital implementation due to sampling rate, sampling offset, and finite bandwidth, resulting from the anti-aliasing low pass prefilter, are computed and compared with those of the analog counterpart. It is shown that the digital IDF performs within 0.6 dB of the ideal analog IDF whenever the prefilter bandwidth exceeds four times the symbol rate and when sampling is performed at the Nyquist rate. The loss can be reduced to 0.3 dB by doubling the sampling rate, where 0.2 dB loss results from finite bandwidth and 0.1 dB results from the digital IDF.

Sadr, R.↗