Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “corrected data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Photometric and spectroscopic footprint corrections in the SLOAN Digital Sky Survey’s 6th data release

We identify and correct numerous errors within the photometric and spectroscopic footprints (SFs) of the Sloan Digital Sky Survey’s (SDSS) 6th data release (DR6). Within the SDSS’s boundaries hundreds of millions of objects have been detected. Yet we present evidence that the boundaries themselves contain a significant number of mistakes that are being revealed for the first time within this paper. Left unaddressed, these can introduce systematic biases into galaxy clustering statistics. Using the DR6 Main Galaxy Sample (MGS) targets as tracers, we reveal inconsistencies between the photometric and SF definitions provided in the Catalog Archive Server (CAS), and the measurements of targets therein. First, we find that 19.7 deg{sup 2} of the DR6 photometric footprint are devoid of MGS targets. In volumes of radii 7 h{sup −1} Mpc, this can cause errors in the expected number of galaxies to exceed 60%. Second, we identify seven areas that were erroneously included or excluded from the SF. Moreover, the tiling algorithm that positioned spectroscopic fibers during and between DRs caused many areas along the edge of the SF to be significantly undersampled relative to the footprint’s interior. Through our corrections, we increase the completeness 2.2% by trimming 3.6% of the area from the existing SF. The sum total of these efforts has generated the most accurate description of the SDSS DR6 footprints ever created.

79 ASTRONOMY AND ASTROPHYSICS↗

NICMOS OBSERVATIONS OF THE TRANSITING HOT JUPITER XO-1b

We refine the physical parameters of the transiting hot Jupiter planet XO-1b and its stellar host XO-1 using Hubble Space Telescope (HST) NICMOS observations. XO-1b has a radius R{sub p} = 1.21 {+-} 0.03 R{sub J} , and XO-1 has a radius R{sub *} = 0.94 {+-} 0.02 R{sub sun}, where the uncertainty in the mass of XO-1 dominates the uncertainty of R{sub p} and R{sub *}. There are no significant differences in the XO-1 system properties between these broadband NIR observations and previous determinations based upon ground-based optical observations. We measure two transit timings from these observations with 9 s and 15 s precision. As a residual to a linear ephemeris model, there is a 2.0{sigma} timing difference between the two HST visits that are separated by three transit events (11.8 days). These two transit timings and additional timings from the literature are sufficient to rule out the presence of an Earth mass planet orbiting in 2:1 mean motion resonance coplanar with XO-1b. We identify and correct for poorly understood 'gain-like' variations present in NICMOS time series data. This correction reduces the effective noise in time series photometry by a factor of 2 for the case of XO-1.

79 ASTRONOMY AND ASTROPHYSICS↗

Is ExacTrac x-ray system an alternative to CBCT for positioning patients with head and neck cancers?

Purpose: To evaluate the usefulness of a six-degrees-of freedom (6D) correction using ExacTrac robotics system in patients with head-and-neck (HN) cancer receiving radiation therapy.Methods: Local setup accuracy was analyzed for 12 patients undergoing intensity-modulated radiation therapy (IMRT). Patient position was imaged daily upon two different protocols, cone-beam computed tomography (CBCT), and ExacTrac (ET) images correction. Setup data from either approach were compared in terms of both residual errors after correction and punctual displacement of selected regions of interest (Mandible, C2, and C6 vertebral bodies).Results: On average, both protocols achieved reasonably low residual errors after initial correction. The observed differences in shift vectors between the two protocols showed that CBCT tends to weight more C2 and C6 at the expense of the mandible, while ET tends to average more differences among the different ROIs.Conclusions: CBCT, even without 6D correction capabilities, seems preferable to ET for better consistent alignment and the capability to see soft tissues. Therefore, in our experience, CBCT represents a benchmark for positioning head and neck cancer patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An Investigation Into HPLC Data Quality Problems

This report summarizes the analyses and results produced by a five-member investigative team of Government, university, and industry experts, established by NASA HQ. The team examined data quality problems associated with high performance liquid chromatography (HPLC) analyses of pigment concentrations in seawater samples produced by the San Diego State University (SDSU) Center for Hydro-Optics and Remote Sensing (CHORS). This report shows CHORS did not validate the methods used before placing them into service to analyze field samples for NASA principal investigators (PIs), even though the HPLC literature contained easily accessible method validation procedures, and the importance of implementing them, more than a decade ago. In addition, there were so many sources of significant variance in the CHORS methodologies, that the HPLC system rarely operated within performance criteria capable of producing the requisite data quality. It is the recommendation of the investigative team to a) not correct the data, b) make all the data that was temporarily sequestered available for scientific use, and c) label the affected data with an appropriate warning, e.g., "These data are not validated and should not be used as the sole basis for a scientific result, conclusion, or hypothesis--independent corroborating evidence is required."

Hooker, Stanford B.↗

A simplified fourwall interference assessment procedure for airfoil data obtained in the Langley 0.3-meter transonic cryogenic tunnel

A simplified fourwall interference assessment method has been described, and a computer program developed to facilitate correction of the airfoil data obtained in the Langley 0.3-m Transonic Cryogenic Tunnel (TCT). The procedure adopted is to first apply a blockage correction due to sidewall boundary-layer effects by various methods. The sidewall boundary-layer corrected data are then used to calculate the top and bottom wall interference effects by the method of Capallier, Chevallier and Bouinol, using the measured wall pressure distribution and the model force coefficients. The interference corrections obtained by the present method have been compared with other methods and found to give good agreement for the experimental data obtained in the TCT with slotted top and bottom walls.

Murthy, A. V.↗

Attenuation correction in emission tomography using the emission data—A review

The problem of attenuation correction (AC) for quantitative positron emission tomography (PET) had been considered solved to a large extent after the commercial availability of devices combining PET with computed tomography (CT) in 2001; single photon emission computed tomography (SPECT) has seen a similar development. However, stimulated in particular by technical advances toward clinical systems combining PET and magnetic resonance imaging (MRI), research interest in alternative approaches for PET AC has grown substantially in the last years. In this comprehensive literature review, the authors first present theoretical results with relevance to simultaneous reconstruction of attenuation and activity. The authors then look back at the early history of this research area especially in PET; since this history is closely interwoven with that of similar approaches in SPECT, these will also be covered. We then review algorithmic advances in PET, including analytic and iterative algorithms. The analytic approaches are either based on the Helgason–Ludwig data consistency conditions of the Radon transform, or generalizations of John’s partial differential equation; with respect to iterative methods, we discuss maximum likelihood reconstruction of attenuation and activity (MLAA), the maximum likelihood attenuation correction factors (MLACF) algorithm, and their offspring. The description of methods is followed by a structured account of applications for simultaneous reconstruction techniques: this discussion covers organ-specific applications, applications specific to PET/MRI, applications using supplemental transmission information, and motion-aware applications. After briefly summarizing SPECT applications, we consider recent developments using emission data other than unscattered photons. In summary, developments using time-of-flight (TOF) PET emission data for AC have shown promising advances and open a wide range of applications. These techniques may both remedy deficiencies of purely MRI-based AC approaches in PET/MRI and improve standalone PET imaging.

61 RADIATION PROTECTION AND DOSIMETRY↗

Special Sensor Microwave Imager/Sounder Updates for the Global Precipitation Measurement V07 Data Suite

Observations from the Special Sensor Microwave Imager/Sounder (SSMIS) onboard the Defense Meteorological Satellite Program F16, F17, F18, and F19 spacecrafts provide a significant portion of the microwave radiometer data within the Global Precipitation Measurement (GPM) mission constellation. In preparation for the GPM Version 7 (V07) data release, SSMIS corrections developed over a decade ago and incorporated in GPM Version 5 (V05) are reexamined and updated. The calibration updates presented here include pointing parameters affecting geolocation and viewing geometry, along-scan bias adjustments to account for scan edge falloffs, and sun angle corrections to account for heating anomalies including an emissive reflector. To address errors in the V05 geolocation, the sensor roll, pitch, yaw, half cone angle, and timing offsets are reanalyzed and updated. The along-scan bias adjustment is updated in a manner consistent with recent Special Sensor Microwave Imager updates to account for variations in scene temperature. Finally, significant improvements to the SSMIS sun angle correction are made by using data from the entire mission, extending the corrections to include the higher frequency channels, and deriving a more consistent channel-to-channel correction. From V05 to V07, the geolocation adjustment is approximately 5-10 km, the earth incidence angle difference is 0-0.4°, and the average brightness temperature change is 0-2 K, but individual pixels may be up to several Kelvin difference depending on sensor and channel. The result of these updates is a significant improvement in the quality and long-term consistency of the SSMIS data that are included in the GPM V07 dataset.

Rachael A Kroodsma↗

THE DATA REDUCTION PIPELINE FOR THE APACHE POINT OBSERVATORY GALACTIC EVOLUTION EXPERIMENT

The Apache Point Observatory Galactic Evolution Experiment (APOGEE), part of the Sloan Digital Sky Survey III, explores the stellar populations of the Milky Way using the Sloan 2.5-m telescope linked to a high resolution (R ∼ 22,500), near-infrared (1.51–1.70 μm) spectrograph with 300 optical fibers. For over 150,000 predominantly red giant branch stars that APOGEE targeted across the Galactic bulge, disks and halo, the collected high signal-to-noise ratio (>100 per half-resolution element) spectra provide accurate (∼0.1 km s{sup −1}) RVs, stellar atmospheric parameters, and precise (≲0.1 dex) chemical abundances for about 15 chemical species. Here we describe the basic APOGEE data reduction software that reduces multiple 3D raw data cubes into calibrated, well-sampled, combined 1D spectra, as implemented for the SDSS-III/APOGEE data releases (DR10, DR11 and DR12). The processing of the near-IR spectral data of APOGEE presents some challenges for reduction, including automated sky subtraction and telluric correction over a 3°-diameter field and the combination of spectrally dithered spectra. We also discuss areas for future improvement.

79 ASTRONOMY AND ASTROPHYSICS↗

Fine Structure of Heliumlike Ions and Determination of the Fine Structure Constant

We report a calculation of the fine-structure splitting in light heliumlike atoms, which accounts for all quantum electrodynamical effects up to order {alpha}{sup 5} Ry. For the helium atom, we resolve the previously reported disagreement between theory and experiment and determine the fine-structure constant with an accuracy of 31 ppb. The calculational results are extensively checked by comparison with the experimental data for different nuclear charges and by evaluation of the hydrogenic limit of individual corrections.

74 ATOMIC AND MOLECULAR PHYSICS↗

Granite Springs Valley, Nevada Play Fairway Analysis - Well data and Temperature Survey

This data is associated with the Nevada Play Fairway project and includes excel files containing raw 2-meter temperature data and corrections. GIS shapefiles and layer files contain ing location and attribute information for the data are included. Well data includes both deep and shallow TG holes, GIS shapefiles and layer files.

15 GEOTHERMAL ENERGY↗

Data smoothing and error detection based on linear interpolation

A method is presented, based on linear interpolation, for detecting and correcting bad data points in a set of data without contaminating the good data points. The method used is not concerned with the small random errors usually attributed to a noisy system. It assumes that the data points which are in error are relatively isolated from each other and that the number of such points is small compared to the total number of data points.

Guerra, V. M.↗

Experiments in infrared multispectral mapping of earth resources

Two evolutionary infrared remote sensing experiments provide the basis for the development of an operational mapping capability for geology exploration. A 10-band radiometer scheduled for an early Shuttle flight has completed an aircraft flight program which demonstrated the utility of a number of narrow spectral channels. A multispectral mapper utilizing an infrared area array detector to acquire simultaneous images in multiple wavelengths is being assembled. A design concept for an operational sensor which employs area arrays for registered multispectral image data acquisition is under study. The sensor would utilize onboard spectral band selection, radiometric correction, and data compression to satisfy the demanding requirements of the user community.

Wellman, J. B.↗

Identification of Aqueous Alteration Products on Low-Albedo Asteroids

The following accomplishments were funded by this grant: 1) Partially supported the writing and publication of "Hydrated Minerals on Asteroids". 2) Partially supported the writing and publication of "Near-Infrared Spectrophotometry of Phobos and Deimos". 3) Partially supported the writing and publication of "Hydrogen concentrations on C-class asteroids derived from remote sensing". 4) Travel to 2002 Lunar and Planetary Sciences Conferences and presentation of "Calculated Water Concentrations on C-Class Asteroids". 5) Reduction of asteroidal spectroscopic data including corrections for thermal flux, as described in the grant proposal and descoping document. These data appeared in the publications listed in items 1, 3 and 4.

Rivkin, Andrew↗

SU-F-R-33: Can CT and CBCT Be Used Simultaneously for Radiomics Analysis

Purpose: To investigate whether CBCT and CT can be used in radiomics analysis simultaneously. To establish a batch correction method for radiomics in two similar image modalities. Methods: Four sites including rectum, bladder, femoral head and lung were considered as region of interest (ROI) in this study. For each site, 10 treatment planning CT images were collected. And 10 CBCT images which came from same site of same patient were acquired at first radiotherapy fraction. 253 radiomics features, which were selected by our test-retest study at rectum cancer CT (ICC>0.8), were calculated for both CBCT and CT images in MATLAB. Simple scaling (z-score) and nonlinear correction methods were applied to the CBCT radiomics features. The Pearson Correlation Coefficient was calculated to analyze the correlation between radiomics features of CT and CBCT images before and after correction. Cluster analysis of mixed data (for each site, 5 CT and 5 CBCT data are randomly selected) was implemented to validate the feasibility to merge radiomics data from CBCT and CT. The consistency of clustering result and site grouping was verified by a chi-square test for different datasets respectively. Results: For simple scaling, 234 of the 253 features have correlation coefficient ρ>0.8 among which 154 features haveρ>0.9 . For radiomics data after nonlinear correction, 240 of the 253 features have ρ>0.8 among which 220 features have ρ>0.9. Cluster analysis of mixed data shows that data of four sites was almost precisely separated for simple scaling(p=1.29 * 10{sup −7}, χ{sup 2} test) and nonlinear correction (p=5.98 * 10{sup −7}, χ{sup 2} test), which is similar to the cluster result of CT data (p=4.52 * 10{sup −8}, χ{sup 2} test). Conclusion: Radiomics data from CBCT can be merged with those from CT by simple scaling or nonlinear correction for radiomics analysis.

60 APPLIED LIFE SCIENCES↗

Airfoil section data obtained in the NACA variable-density tunnel as affected by support interference and other corrections

The results of an investigation of the effect of support interference on airfoil drag data obtained in the variable-density tunnel are presented. As a result of the support interference, previously published airfoil data from the variable-density tunnel have shown too large drag coefficients and too large a rate of increase of drag coefficients and too large a rate increase of drag coefficients with airfoil thickness. The practical effect of the corrections on the choice of the optimum section is briefly considered and corrected data for a selected list of airfoils are presented as a convenience to the designer. Methods of correcting published data for other airfoils are presented.

Jacobs, Eastman N↗

Patient motion effects on the quantification of regional myocardial blood flow with dynamic PET imaging

Purpose: Patient motion is a common problem during dynamic positron emission tomography (PET) scans for quantification of myocardial blood flow (MBF). The purpose of this study was to quantify the prevalence of body motion in a clinical setting and evaluate with realistic phantoms the effects of motion on blood flow quantification, including CT attenuation correction (CTAC) artifacts that result from PET–CT misalignment. Methods: A cohort of 236 sequential patients was analyzed for patient motion under resting and peak stress conditions by two independent observers. The presence of motion, affected time-frames, and direction of motion was recorded; discrepancy between observers was resolved by consensus review. Based on these results, patient body motion effects on MBF quantification were characterized using the digital NURBS-based cardiac-torso phantom, with characteristic time activity curves (TACs) assigned to the heart wall (myocardium) and blood regions. Simulated projection data were corrected for attenuation and reconstructed using filtered back-projection. All simulations were performed without noise added, and a single CT image was used for attenuation correction and aligned to the early- or late-frame PET images. Results: In the patient cohort, mild motion of 0.5 ± 0.1 cm occurred in 24% and moderate motion of 1.0 ± 0.3 cm occurred in 38% of patients. Motion in the superior/inferior direction accounted for 45% of all detected motion, with 30% in the superior direction. Anterior/posterior motion was predominant (29%) in the posterior direction. Left/right motion occurred in 24% of cases, with similar proportions in the left and right directions. Computer simulation studies indicated that errors in MBF can approach 500% for scans with severe patient motion (up to 2 cm). The largest errors occurred when the heart wall was shifted left toward the adjacent lung region, resulting in a severe undercorrection for attenuation of the heart wall. Simulations also indicated that the magnitude of MBF errors resulting from motion in the superior/inferior and anterior/posterior directions was similar (up to 250%). Body motion effects were more detrimental for higher resolution PET imaging (2 vs 10 mm full-width at half-maximum), and for motion occurring during the mid-to-late time-frames. Motion correction of the reconstructed dynamic image series resulted in significant reduction in MBF errors, but did not account for the residual PET–CTAC misalignment artifacts. MBF bias was reduced further using global partial-volume correction, and using dynamic alignment of the PET projection data to the CT scan for accurate attenuation correction during image reconstruction. Conclusions: Patient body motion can produce MBF estimation errors up to 500%. To reduce these errors, new motion correction algorithms must be effective in identifying motion in the left/right direction, and in the mid-to-late time-frames, since these conditions produce the largest errors in MBF, particularly for high resolution PET imaging. Ideally, motion correction should be done before or during image reconstruction to eliminate PET-CTAC misalignment artifacts.

60 APPLIED LIFE SCIENCES↗

The Completed SDSS-IV extended Baryon Oscillation Spectroscopic Survey: Large-scale structure catalogues for cosmological analysis

ABSTRACT We present large-scale structure catalogues from the completed extended Baryon Oscillation Spectroscopic Survey (eBOSS). Derived from Sloan Digital Sky Survey (SDSS) IV Data Release 16 (DR16), these catalogues provide the data samples, corrected for observational systematics, and random positions sampling the survey selection function. Combined, they allow large-scale clustering measurements suitable for testing cosmological models. We describe the methods used to create these catalogues for the eBOSS DR16 Luminous Red Galaxy (LRG) and Quasar samples. The quasar catalogue contains 343 708 redshifts with 0.8 < z < 2.2 over 4808 deg2. We combine 174 816 eBOSS LRG redshifts over 4242 deg2 in the redshift interval 0.6 < z < 1.0 with SDSS-III BOSS LRGs in the same redshift range to produce a combined sample of 377 458 galaxy redshifts distributed over 9493 deg2. Improved algorithms for estimating redshifts allow that 98 per cent of LRG observations result in a successful redshift, with less than one per cent catastrophic failures (Δz > 1000 km s−1). For quasars, these rates are 95 and 2 per cent (with Δz > 3000 km s−1). We apply corrections for trends between the number densities of our samples and the properties of the imaging and spectroscopic data. For example, the quasar catalogue obtains a χ2/DoF = 776/10 for a null test against imaging depth before corrections and a χ2/DoF= 6/8 after. The catalogues, combined with careful consideration of the details of their construction found here-in, allow companion papers to present cosmological results with negligible impact from observational systematic uncertainties.

79 ASTRONOMY AND ASTROPHYSICS↗

Correcting For Capacitance In Tests Of Solar Cells

Modified procedure for testing solar photovoltaic cells and modified software for processing test data provide corrections for effects of cell capacitance. Procedure and software needed because (a) some photovoltaic devices (for example, silicon solar cells with back-surface field region) store minority charge carriers in cell junction and thus exhibit significant capacitance, (b) capacitance affects current-vs.-voltage (I-V) measurements made when transient load connected to cell, and (c) transient load used in unmodified version of test procedure. Corrected I-V curve obtained in test of solar cell according to modified procedure approximates true cell voltage vs. cell current more closely.

Mueller, Robert L.↗