Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “controller test bed”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

A simple way to measure daily lifestyle regularity

A brief diary instrument to quantify daily lifestyle regularity (SRM-5) is developed and compared with a much longer version of the instrument (SRM-17) described and used previously. Three studies are described. In Study 1, SRM-17 scores (2 weeks) were collected from a total of 293 healthy control subjects (both genders) aged between 19 and 92 years. Five items (1) Get out of bed, (2) First contact with another person, (3) Start work, housework or volunteer activities, (4) Have dinner, and (5) Go to bed were then selected from the 17 items and SRM-5 scores calculated as if these five items were the only ones collected. Comparisons were made with SRM-17 scores from the same subject-weeks, looking at correlations between the two SRM measures, and the effects of age and gender on lifestyle regularity as measured by the two instruments. In Study 2 this process was repeated in a group of 27 subjects who were in remission from unipolar depression after treatment with psychotherapy and who completed SRM-17 for at least 20 successive weeks. SRM-5 and SRM-17 scores were then correlated within an individual using time as the random variable, allowing an indication of how successful SRM-5 was in tracking changes in lifestyle regularity (within an individual) over time. In Study 3 an SRM-5 diary instrument was administered to 101 healthy control subjects (both genders, aged 20-59 years) for two successive weeks to obtain normative measures and to test for correlations with age and morningness. Measures of lifestyle regularity from SRM-5 correlated quite well (about 0.8) with those from SRM-17 both between subjects, and within-subjects over time. As a detector of irregularity as defined by SRM-17, the SRM-5 instrument showed acceptable values of kappa (0.69), sensitivity (74%) and specificity (95%). There were, however, differences in mean level, with SRM-5 scores being about 0.9 units [about one standard deviation (SD)] above SRM-17 scores from the same subject-weeks. SRM-5 scores also deviated more from a Gaussian distribution than did SRM-17 ones. In a study with a sample size of 101, the new SRM-5 instrument yielded scores with a mean of 4.11 and an SD of 1.13. Correlations between lifestyle regularity and age, and between lifestyle regularity and morningness appeared similar whether 5-item or 17-item SRM measures were used. When a gender difference in lifestyle regularity appeared, it was detected by both SRM-5 and SRM-17 measures.

Non-NASA Center↗

Arterial Structure and Function in Women and Men Following Long Duration Bed Rest

Orthostatic intolerance is a well-recognized consequence of space flight and bed rest (BR), with a greater incidence reported in women. We hypothesized that leg, but not arm, arterial structure and function would be altered following prolonged BR, as a model of space flight, and that women would be more susceptible to BR-induced deconditioning than men. METHODS: Ten volunteers (5 males, 5 females) completed 90 d of 6 head-down BR. Subjects participated in tests of brachial (BA) and anterior tibial (AT) artery endothelium-dependent (flow mediated dilation [FMD] following 5-7 min of arterial occlusion) and endothelium-independent (0.4 mg sublingual nitroglycerin [SN]) vasodilation before BR (PRE) and on days 7 (BR7), 21 (BR21), and 90 (BR90) of BR. Vessel diameter and intimal medial thickness (IMT) were measured by ultrasound. IMT, baseline diameter, and percent change in diameter from baseline during FMD and SN tests were compared across BR and between genders using repeated measures two-way ANOVA with Bonferroni post-hoc tests in which PRE and women were control conditions. RESULTS: Baseline vessel diameter was lower in women than in men in both the BA (p=0.005) and AT (p=0.01) across all days. Baseline AT diameter decreased during BR (p=0.01) and tended to be more profound in women (interaction, p=0.06). AT diameter was reduced in women at BR21 and BR90 (p<0.01) but not in men. In contrast, there was no BR effect on baseline BA diameter. IMT also decreased in the AT (p<0.001) but not in the BA during BR; AT IMT was reduced by BR21 (p<0.05). As a group, there was no effect of BR on AT FMD, BA FMD, and AT SN-dilation, although BA SN-dilation was significantly reduced on BR21 (p=0.01). Across all BR days, women exhibited higher AT FMD (p=0.03), BA FMD (p=0.02), and BA SN-dilation (p=0.01) and tended to demonstrate greater AT SN-dilation (p=0.11). CONCLUSIONS: These preliminary results suggest that arterial remodeling occurs during BR in the leg (decreased diameter and IMT), but not in the arm, and that women appear to be more responsive to BR than men. These changes in the leg, coupled with larger responses to direct and indirect stimulation of the arterial smooth muscle, may be related to the greater incidence of orthostatic intolerance in women after BR and space flight.

Lee, Stuart M. C.↗

Evaluating the Adsorptive Capabilites of Chemsorb 1000 and Chemsorb 1425

The removal of trace contaminants from spacecraft cabin air is necessary for crew health and comfort during long duration space exploration missions. The air revitalization technologies used in these future exploration missions will evolve from current ISS ISS State-of-Art (SOA) and is being designed and tested by the Advanced Exploration Systems (AES) Program's Atmosphere Resource Recovery and Environmental Monitoring (ARREM) project. The ARREM project is working to mature optimum atmosphere revitalization and environmental monitoring system architectures to enable exploration beyond Lower Earth Orbit (LEO). The Air Revitalization Lab at KSC is one of six NASA field centers participating in the ARREM that specializes in adsorbent and catalyst characterization with simulated spacecraft gas streams using combinations of pressure, O2 partial pressure, CO2 partial pressure, and humidity that are representative of a range of anticipated cabin atmospheric conditions and loads. On board ISS, the Trace Contaminant Control Subassembly (TCCS) provides active control of trace contaminants from the cabin atmosphere utilizing physical adsorption, thermal catalytic oxidation, and chemical adsorption processes. High molecular weight contaminants and ammonia (NH3) are removed a granular activated carbon treated with approx. 10% by weight phosphoric acid (H3PO4) (B-S Type 3032 4×6 mesh), which is expendable and is periodically refurbished. The Type 3032 granular activated carbon bed is no longer commercially available and therefore it is important to characterize the efficiency and capacity of commercially available NH3 sorbents. This paper describes the characterization of two Molecular Products LTD activated carbons: Chemsorb 1000 and Chemsorb 1425. Untreated activated carbons (e.g. Chemsorb 1000) remove contaminants by physisorption, which concentrates the contaminant within the pores of the carbon while letting air to pass through the sorbent4. Low molecular weight or polar gases (e.g. HCl, SO2, formaldehyde, and NH3) are not removed by physisorption and typically require chemisorption for removal. Treated activated carbons (e.g. Chemsorb 1425) are impregnated with a a chemical agent (e.g. phosphoric acid) that reacts with those gases, converting them to solids or salts within the carbon and removes them from the air stream. This process occurs via neutralization or catalysis reactions and adsorption capacity is exhaustedwhen the available impregnated chemicals are consumed. Moisture affects removal performance since adsorption sites within the pores are filled with water. The performance of impregnated carbons may be enhanced by moisture content because the mechanisms of contaminant removal are chemical reactions that occur in reagents contained within the pores. The adsorptive capacity data (mol/kg) of Chemsorb 1000 and 1425 for gas mixtures (ethanol, acetone, toluene, acetaldehyde, dichloromethane, and xylene) was measured with 40% relative humidity at 23 deg C air temperature. The adsorptive capacity data (mol/kg) of Chemsorb 1425 was measured using NH3 gas streams.

adsorptive capacities↗

Development of a machine vision system for automated structural assembly

Research is being conducted at the LaRC to develop a telerobotic assembly system designed to construct large space truss structures. This research program was initiated within the past several years, and a ground-based test-bed was developed to evaluate and expand the state of the art. Test-bed operations currently use predetermined ('taught') points for truss structural assembly. Total dependence on the use of taught points for joint receptacle capture and strut installation is neither robust nor reliable enough for space operations. Therefore, a machine vision sensor guidance system is being developed to locate and guide the robot to a passive target mounted on the truss joint receptacle. The vision system hardware includes a miniature video camera, passive targets mounted on the joint receptacles, target illumination hardware, and an image processing system. Discrimination of the target from background clutter is accomplished through standard digital processing techniques. Once the target is identified, a pose estimation algorithm is invoked to determine the location, in three-dimensional space, of the target relative to the robots end-effector. Preliminary test results of the vision system in the Automated Structural Assembly Laboratory with a range of lighting and background conditions indicate that it is fully capable of successfully identifying joint receptacle targets throughout the required operational range. Controlled optical bench test results indicate that the system can also provide the pose estimation accuracy to define the target position.

Sydow, P. Daniel↗

Gradient Compression Garments as a Countermeasure to Post-Space Flight Orthostatic Intolerance: Potential Interactions with the Maximum Absorbency Garment

Astronauts and cosmonauts may experience symptoms of orthostatic intolerance during re-entry, landing, and for several days post-landing following short- and long-duration spaceflight. Presyncopal symptoms have been documented in approximately 20% of short-duration and greater than 60% of long-duration flyers on landing day specifically during 5-10 min of controlled (no countermeasures employed at the time of testing) stand tests or 80 deg head-up tilt tests. Current operational countermeasures to orthostatic intolerance include fluid loading prior to and whole body cooling during re-entry as well as compression garments that are worn during and for up to several days after landing. While both NASA and the Russian space program have utilized compression garments to protect astronauts and cosmonauts traveling on their respective vehicles, a "next-generation" gradient compression garment (GCG) has been developed and tested in collaboration with a commercial partner to support future space flight missions. Unlike previous compression garments used operationally by NASA that provide a single level of compression across only the calves, thighs, and lower abdomen, the GCG provides continuous coverage from the feet to below the pectoral muscles in a gradient fashion (from approximately 55 mm Hg at the feet to approximately 16 mmHg across the abdomen). The efficacy of the GCG has been demonstrated previously after a 14-d bed rest study without other countermeasures and after short-duration Space Shuttle missions. Currently the GCG is being tested during a stand test following long-duration missions (~6 months) to the International Space Station. While results to date have been promising, interactions of the GCG with other space suit components have not been examined. Specifically, it is unknown whether wearing the GCG over NASA's Maximum Absorbency Garment (MAG; absorbent briefs worn for the collection of urine and feces while suited during re-entry and landing) will interfere with the effectiveness of the GCG or conversely whether the GCG will reduce the fluid absorption capabilities of the MAG. Methods: This operational, directed study, will (1) determine whether the effectiveness of the GCG is affected by the MAG with regard to cardiovascular responses to head-up tilt, the standard orthostatic intolerance test employed for astronauts and bed rest subjects; (2) determine whether the effectiveness of the MAG is compromised by the GCG tested by injecting a standard fluid volume (950 ml in 3 separate simulated "urine voids") at a standardized rate (30 ml/sec); and (3) determine whether comfort is affected by wearing the MAG under the GCG using a standardized questionnaire. Results from this study will guide future development and operational use of the GCG and MAG to maximize crew health, safety, and comfort.

Lee, S. M. C.↗

Intelligent systems technology infrastructure for integrated systems

A system infrastructure must be properly designed and integrated from the conceptual development phase to accommodate evolutionary intelligent technologies. Several technology development activities were identified that may have application to rendezvous and capture systems. Optical correlators in conjunction with fuzzy logic control might be used for the identification, tracking, and capture of either cooperative or non-cooperative targets without the intensive computational requirements associated with vision processing. A hybrid digital/analog system was developed and tested with a robotic arm. An aircraft refueling application demonstration is planned within two years. Initially this demonstration will be ground based with a follow-on air based demonstration. System dependability measurement and modeling techniques are being developed for fault management applications. This involves usage of incremental solution/evaluation techniques and modularized systems to facilitate reuse and to take advantage of natural partitions in system models. Though not yet commercially available and currently subject to accuracy limitations, technology is being developed to perform optical matrix operations to enhance computational speed. Optical terrain recognition using camera image sequencing processed with optical correlators is being developed to determine position and velocity in support of lander guidance. The system is planned for testing in conjunction with Dryden Flight Research Facility. Advanced architecture technology is defining open architecture design constraints, test bed concepts (processors, multiple hardware/software and multi-dimensional user support, knowledge/tool sharing infrastructure), and software engineering interface issues.

Lum, Henry↗

Countermeasures for Mitigation of Sensorimotor Decrements Following Head-Down Bed Rest

BACKGROUND Astronauts experience postflight disturbances in postural and locomotor control due to sensorimotor adaptations during spaceflight. These alterations may have adverse consequences if a rapid egress is required after landing. Although exercise is partially effective for mitigating cardiovascular and muscular deconditioning, additional countermeasures are needed to further preserve sensorimotor function for exploration missions. We have identified proprioceptive training and electrical muscle stimulation (EMS) as promising in-flight countermeasures. Since prolonged head down bed rest (HDBR) is a spaceflight analog for body unloading and causes postural and locomotor control decrements that parallel those observed after spaceflight, it can be used to accelerate the development of these countermeasures. METHODS This study will determine the effects of proprioceptive training and EMS on functional task performance and sensorimotor function following 60 days of 6° HDBR. Subjects will be randomly assigned to one of four groups: 1) an EMS arm, 2) a proprioceptive training arm, 3) an exercise plus proprioceptive training arm, and 4) a control arm. The EMS countermeasure will include daily bilateral stimulation of the quadriceps femoris muscle (30 minutes per session). Proprioceptive training will be performed three days per week (20 minutes per session) consisting of body-loaded postural tasks in the horizontal position on an air bearing sled. Exercise training will mimic current protocols used on the International Space Station, but treadmill aerobic exercise will be replaced with additional cycling aerobic exercise. Primary outcome measures will include pre and post HDBR functional tests that are representative of high priority exploration mission tasks and require high demand for dynamic control of postural stability. Additional measures will be used to identify the key physiological factors contributing to countermeasure benefits. Given the constrained samples size, a Bayesian modelling approach will be used to quantify the probability that there is an effect of a given magnitude. COUNTERMEASURE UPDATES Proprioceptive countermeasure design enhancements and human in the loop pilot testing continued through the Crew Health Countermeasures (CHC) Systems Capability Leadership Team (SCLT). The primary goals of this work were to enhance the visual feedback system’s capabilities and develop a proprioceptive training program for 60 days of HDBR. Six healthy non-astronaut volunteers participated in four pilot training sessions to systematically examine how each training variable (e.g., axial load, foot placement, and software profile) affects the overall proprioceptive challenge. The resulting training program will maintain an appropriate challenge during 60 days of HDBR by progressively decreasing the subject’s base of support, increasing tilt board target distances, and increasing axial loads using both subjective verbal feedback and objective performance data. RELEVANCE The deliverable from this project will be proof-of-concept sensorimotor countermeasure designs for functional task performance with full assessment of efficacy in a spaceflight analog. If the countermeasures are effective, they will be translated for validation with the suite of operationally implemented in-flight countermeasures.

T R Macaulay↗

Countermeasures for Mitigation of Sensorimotor Decrements Following Head-Down Bed Rest

BACKGROUND Astronauts experience postflight disturbances in postural and locomotor control due to sensorimotor adaptations during spaceflight. These alterations may have adverse consequences if a rapid egress is required after landing. Although exercise is partially effective for mitigating cardiovascular and muscular deconditioning, additional countermeasures are needed to further preserve sensorimotor function for exploration missions. We have identified proprioceptive training and electrical muscle stimulation (EMS) as promising in-flight countermeasures. Since prolonged head down bed rest (HDBR) is a spaceflight analog for body unloading and causes postural and locomotor control decrements that parallel those observed after spaceflight, it can be used to facilitate the development of these countermeasures. METHODS This study will determine the effects of proprioceptive training and EMS on functional task performance and sensorimotor function following 60 days of 6° HDBR. Subjects will be randomly assigned to one of four groups: 1)an EMS arm, 2) a proprioceptive training arm, 3) an exercise plus proprioceptive training arm, and 4) a control arm. The EMS countermeasure will include daily bilateral stimulation of selected bilateral lower extremity muscles (30 minutes per session). Proprioceptive training will be performed three days per week (20 minutes per session) consisting of body-loaded postural tasks in the horizontal position on an air bearing sled. Exercise training will mimic current protocols used on the International Space Station, but treadmill aerobic exercise will be replaced with additional cycling aerobic exercise. Primary outcome measures will include pre and post HDBR functional tests that are representative of high priority exploration mission tasks and require high demand for dynamic control of postural stability. Additional measures will be used to identify the key physiological factors contributing to countermeasure benefits. Given the constrained samples size, a Bayesian modelling approach will be used to quantify the probability that there is an effect of a given magnitude. HARDWARE AND PROTOCOL DEVELOPMENT Proprioceptive countermeasure design enhancements continued as part of the Mars Campaign Office (MCO) Crew Health and Performance (CHP) Crew Health Countermeasures (CHC). The primary goals of this work were to assemble a portable version of the countermeasure system that can be used at the :envihab facility, expand the software feedback system’s capabilities, and develop an actuator loading system that mimics what could be used on the International Space Station. In addition, one major piece of exercise hardware used in previous HDBR studies, the Horizontal Squat Device, was reassembled and restored to full functionality. Human-in-the-loop pilot testing is ongoing, prior to shipping both devices to the :envihab HDBR facility. Evaluations are also underway for the best EMS device technologies and specific methods. Finally, assessment techniques are being translated for administration in the horizontal position (e.g., leg dexterity and foot sole skin sensitivity). Our current goals are to refine the countermeasure training and assessment techniques and integrate protocols across multiple modalities. RELEVANCE The deliverable from this project will be proof-of-concept sensorimotor countermeasure designs for functional task performance with full assessment of efficacy in a spaceflight analog. If one or more countermeasures are effective, they will be translated for validation with the suite of operationally implemented in-flight countermeasures. ACKNOWLEDGEMENT This work is supported by NASA’s Human Research Program Human Health Countermeasures Element and by the Canadian Space Agency (L. Bent).

T R Macaulay↗

Effect of Tungsten L-PBF Feedstock Modification on Performance in Bending

Additively manufactured tungsten is a candidate refractory material for high-temperature aerospace and nuclear fusion/fission applications. The printability of pure tungsten is challenged by cracking defects arising from the metal’s high ductile-to-brittle transition temperature and low solubility of interstitial impurities. Furthermore, the cast microstructure inherent to the laser powder bed fusion (L-PBF) process has limited strength compared to worked microstructures common in wrought tungsten. Aside from process-related techniques to mitigate defects and increase strength (e.g., heated build chambers, multi-laser systems, low oxygen environmental control, etc.), micro-alloying additions can positively influence tungsten printability. In this work, pure tungsten L-PBF feedstock was modified with 1 wt% additions of ceramic compound nano-powders. Wrought and printed bars were evaluated in four-point bending. Flexural strength and fractography were primary means of comparison to assess the effect of the feedstock modification on printed tungsten mechanical performance.

Tungsten-based alloys↗

Autonomous Navigation, Guidance, and Control Software in a Low SWaP Box

Onboard autonomy is a necessity for responsive space operations. Autonomous navigation, guidance, and control (NGC) enables space missions to reduce their dependence on high demand ground assets and costly ground personnel. It also allows for in-situ decision making and higher return on mission data. A flight software and hardware system providing this capability, called “autoNGC,” is currently being developed at NASA Goddard Space Flight Center for infusion into multiple future missions. The autoNGC flight software is built on the plug-and-play architecture of the core Flight System (cFS) consisting of the standard cFS apps and newly developed autoNGC interface apps and libraries. The various apps cooperate through communication over the message-based software bus. With the plug-and-play architecture of autoNGC, cFS apps can easily be added and replaced to meet the needs of different missions, even after launch. The first flight software release of autoNGC is targeted for Summer 2024 to provide autonomous navigation at the Moon and beyond. It can perform sensor fusion of multiple measurement types including pseudo-range from a Global Navigation Satellite System (GNSS) receiver (including weak signal), 1-way and 2-way range and Doppler from ground stations (i.e., direct to Earth (DTE)), bearing and range from optical camera images, and accelerometer data. Accurate onboard navigation and timing is obtained through the Goddard Enhanced Onboard Navigation System (GEONS) software library which fuses different measurement types through an extended Kalman filter (EKF) framework. Optical measurements that are ingested in GEONS are first extracted from optical images by the cFS Goddard Image Analysis and Navigation Tool (cGIANT) app. If the imaged body is far enough away that it appears as a pixel or cluster of pixels, then bearing angles to the body centroid can be provided. If the body is close enough and the shape is known coarsely, then bearing angles and range to the body centroid can be derived from the limb. Bearing angles to individual surface features can also be extracted (i.e., terrain relative navigation (TRN)). Onboard guidance and control capabilities are being developed for a future release to perform autonomous station-keeping and trajectory correction maneuvers in multiple orbital regimes. Capabilities to enable distributed systems missions and constellations, such as crosslink measurements, and onboard time management are being developed as well. The first hardware implementation of autoNGC is a minimal size, weight, and power (SWaP) design allowing for inclusion into CubeSats and SmallSat-size buses. Advancements in miniaturized space processors, such as the SpaceCube 3.0 Mini and the SpaceCube Mini-Z are utilized for low SWaP while maintaining a high level of performance. The current enclosure design is 12 cm x 17 cm x 13.5 cm. The box mass is expected to be less than 2 kg, and the nominal power is 21 W. In order to accommodate a wide range of missions, the hardware interfaces are designed for flexibility with a variety of sensor inputs. Through comprehensive testing in the software-in-the-loop, processor-in-the-loop, and hardware-in-the-loop test beds that are concurrently being developed, autoNGC is expected to achieve TRL 6 by late 2024.

Sun Hur-Diaz↗

Demonstration of a Non-Toxic Reaction Control Engine

Three non-toxic demonstration reaction control engines (RCE) were successfully tested at the Aerojet Sacramento facility under a technology contract sponsored by the National Aeronautics and Space Administration s (NASA) Marshall Space Flight Center (MSFC). The goals of the NASA MSFC contract (NAS8-01109) were to develop and expand the technical maturity of a non-toxic, on-orbit auxiliary propulsion system (APS) thruster under the auspices of the Exploration Systems Mission Directorate. The demonstration engine utilized Liquid Oxygen (LOX) and Ethanol as propellants to produce 870 lbf thrust. The Aerojet RCE s were successfully acceptance tested over a broad range of operating conditions. Steady state tests evaluated engine response to varying chamber pressures and mixture ratios. In addition to the steady state tests, a variety of pulsing tests were conducted over a wide range of electrical pulse widths (EPW). Each EPW condition was also tested over a range of percent duty cycles (DC), and bit impulse and pulsing specific impulse were determined for each of these conditions. White Sands Test Facility (WSTF) in April 2005 for incorporation into a cryogenic Auxiliary Propulsion System Test Bed (APSTB). The APSTB is a test article that will be utilized in an altitude test cell to simulate anticipated mission applications. The objectives of this APSTB testing included evaluation of engine performance over an extended duty cycle map of propellant pressure and temperature, as well as engine and system performance at typical mission duty cycles over extended periods of time. This paper provides acceptance test results and a status of the engine performance as part of the system level testing. Subsequent to acceptance testing at Aerojet, these three engines were delivered to the NASA

Robinson, Philip J.↗

Metallic Powder Core Tubular Wire (PCTW) Development for Additive Manufacturing

NASA Langley Research Center (LaRC) in Hampton, VA, and the Center for Welding, Joining, and Coating Research (CWJCR) in the Department of Metallurgical and Materials Engineering at the Colorado School of Mines (CSM) in Golden, CO, have collaborated for nearly fifteen years to develop metallic powder core tubular wire (PCTW) feedstock for additive manufacturing (AM) using electron beam deposition. The motivation for this development was to offset dealloying observed during deposition of titanium and aluminum alloy solid wire feedstock in the LaRC electron beam freeform fabrication (EBF3) system and to explore novel alloy compositions by tailoring the powder fill. EBF3 is a fusion-based AM process that is performed under vacuum and is consequently prone to vaporization loss of low vapor pressure alloying elements. Research spanning four graduate student research projects succeeded in developing the basic methodology to fabricate PCTW, the mass balance equations used to define the powder fill, microstructure control through particulate inoculation, and the feasibility of producing metal matrix composite materials. Metallic PCTW is comprised of a thin foil sheath wrapped around a powder blend. Fabrication of PCTW at CSM was accomplished using a tubular wire mill system to first bend a flat strip into a u-shaped cross section, deposit a powder fill, create a lap joint to seal the wire, and draw to final diameter. Powder management systems were developed to ensure uniform mixing of powder constituents and identify feed rates for optimum fill ratios. Processing parameters were successfully developed for titanium and aluminum alloy sheaths to account for material work hardening during drawing. Mass balance equations were developed to account for compositional contributions of the sheath and powder fill. PCTW composition can be adjusted through selection of the sheath or powder materials. PCTWs were successfully developed to offset Al loss in deposits of Ti-6-4 and Mg loss in Al 6061, resulting in deposits that were within the composition limits for each material. Ti-6-4 deposits were fabricated using PCTW comprised of commercially pure (CP) titanium sheath and a fill of pre-alloyed Ti-6-4 powder with additions of elemental Al and V powders. Additions of both elements were required to account for the CP Ti from the sheath, and Al was further enhanced to offset documented losses in EBF3 deposits. For Al 6061 deposits, composition was modulated through the choice of sheath material. The PCTW was made using an Al 5052 sheath to supplement Mg content and a fill composition of pre-alloyed 6061 powder with additions of Si and Cu.The slower solidification rate of the EBF3 process compared with laser powder bed fusion processes can lead to coarse-grained microstructures and mechanical property anisotropy. EBF3deposits of Ti-6-4 exhibited large epitaxially grown β grains, which result in degraded mechanical properties in the deposition direction. Microstructure refinement was achieved through a combination of electron beam modulation and the use of a PCTW designed for Ti-6-4 deposits and modified by the addition of powder made from Fe and B. Resulting deposits exhibited reductions in β grain size, α phase colony intercept length and lath width, and an increased volume fraction of β phase. The mechanism of microstructure refinement was related to precipitation of boride particles. Hardness testing confirmed that mechanical property anisotropy was reduced and an overall increase in hardness was achieved.Metal matrix composite (MMC) materials offer strength and stiffness benefits over unreinforced materials. Two methods were investigated using PCTW technology for producing Al 6061 basedMMC materials; the direct addition of SiC reinforcing particles and the in-situ generation of reinforcements through reaction synthesis of precursor powders. Al 6061 based MMCs reinforced with SiC exhibited particle clustering and formation of aluminum carbides during deposition. The application of a Ni coating to the SiC particles prior to incorporation into the powder fill eliminated aluminum carbide formation and aided particle distribution during deposition. Modulation of beam focus and power further reduced aluminum carbide formation and aided particle distribution. In reaction synthesis, precursor additions undergo an exothermic reaction during deposition to form new ceramic products, generally of finer scale than the initial precursor components. The product phases provide reinforcement in the MMC and act as nucleation sites during solidification, resulting in grain refinement, improved mechanical properties, and reduced susceptibility to solidification cracking. Higher tensile strength and stiffness were demonstrated in Al 6061 based MMCs with 2 vol% reinforcement. These combined research efforts demonstrate the potential of PCTW technology for customizing of alloy composition and achieving microstructure control. A manufacturing process for titanium- and aluminum-based PCTWs was developed based on iterative design, theoretical calculations, and empirical data. PCTW technology successfully mitigated Al loss from Ti-6-4 and Mg loss in Al 6061, resulted in grain refinement in Ti-6-4, and demonstrated fabrication of Al based MMCs

Marcia S Domack↗

Cardiovascular Deconditioning in Humans: Alteration in Cardiovascular Regulation and Function During Simulated Microgravity

Alterations in cardiovascular regulation and function that occur during and after space flight have been reported. These alterations are manifested, for example, by reduced orthostatic tolerance upon reentry to the earth's gravity from space. However, the precise physiologic mechanisms responsible for these alterations remain to be fully elucidated. Perhaps, as a result, effective countermeasures have yet to be developed. In this project we apply a powerful, new method - cardiovascular system identification (CSI) - for the study of the effects of space flight on the cardiovascular system so that effective countermeasures can be developed. CSI involves the mathematical analysis of second-to-second fluctuations in non-invasively measured heart rate, arterial blood pressure (ABP), and instantaneous lung volume (ILV - respiratory activity) in order to characterize quantitatively the physiologic mechanisms responsible for the couplings between these signals. Through the characterization of all the physiologic mechanisms coupling these signals, CSI provides a model of the closed-loop cardiovascular regulatory state in an individual subject. The model includes quantitative descriptions of the heart rate baroreflex, autonomic function, as well as other important physiologic mechanisms. We are in the process of incorporating beat-to-beat fluctuations of stroke volume into the CSI technique in order to quantify additional physiologic mechanisms such as those involved in control of peripheral vascular resistance and alterations in cardiac contractility. We apply CSI in conjunction with the two general protocols of the Human Studies Core project. The first protocol involves ground-based, human head down tilt bed rest to simulate microgravity and acute stressors - upright tilt, standing and bicycle exercise - to provide orthostatic and exercise challenges. The second protocol is intended to be the same as the first but with the addition of sleep deprivation to determine whether this contributes to cardiovascular alterations. In these studies, we focus on the basic physiologic mechanisms responsible for the alterations in cardiovascular regulation and function during the simulated microgravity in order to formulate hypotheses regarding what countermeasures are likely to be most effective. Compared to our original proposal, the protocol we are using has been slightly modified to lengthen the bed rest period to 16 days and streamline the data collection. These modifications provide us data on a longer bed rest period and have enabled us to increase our subject throughput. Based on review of our preliminary data we have decided to test a countermeasure which is applied the very end of the bed rest period. We will use the same bed rest protocol to test this countermeasure. We anticipate completing the baseline data collection in our first protocol plus testing of the countermeasure in an additional eight subjects, at which time we plan to initiate the second protocol which includes sleep deprivation. In future studies, we plan to apply CSI to test other potential countermeasures in conjunction with the same bed rest, sleep deprivation and acute stressor models. We also anticipate applying CSI for studying astronauts before and after space flight and ultimately, during space flight. The application of CSI is providing information relevant to the development and evaluation of effective countermeasures allowing humans to adapt appropriately upon re-exposure to a gravity field, and to live and work for longer periods of time in microgravity.

Cohen, Richard↗

Development and Testing of a Sorbent-Based Atmosphere Revitalization System 2010/2011

Spacecraft being developed for future exploration missions incorporate Environmental Control and Life Support Systems (ECLSS) that limit weight, power, and volume thus requiring systems with higher levels of efficiency while maintaining high dependability and robustness. For air revitalization, an approach that meets those goals utilizes a regenerative Vacuum-Swing Adsorption (VSA) system that removes 100% of the CO2 from the cabin atmosphere as well as 100% of the water. A Sorbent Based Atmosphere Revitalization (SBAR) system is a VSA system that utilizes standard commercial adsorbents that have been proven effective and safe in spacecraft including Skylab and the International Space Station. The SBAR system is the subject of a development, test, and evaluation program that is being conducted at NASA s Marshall Space Flight Center. While previous testing had validated that the technology is a viable option, potential improvements to system design and operation were identified. Modifications of the full-scale SBAR test articles and adsorption cycles have been implemented and have shown significant performance gains resulting in a decrease in the consumables required for a mission as well as improved mission safety. Previous testing had utilized single bed test articles, during this period the test facility was enhanced to allow testing on the full 2-bed SBAR system. The test facility simulates a spacecraft ECLSS and allows testing of the SBAR system over the full range of operational conditions using mission simulations that assess the real-time performance of the SBAR system during scenarios that include the metabolic transients associated with extravehicular activity. Although future manned missions are currently being redefined, the atmosphere revitalization requirements for the spacecraft are expected to be quite similar to the Orion and the Altair vehicles and the SBAR test program addressed validation to the defined mission requirements as well as operation in other potential vehicle architectures. The development program, including test articles, the test facility, and tests and results through early 2011 is discussed.

Miller, Lee A.↗

Reciprocating Feed System Development Status

The reciprocating feed system (RFS) is an alternative means of providing high pressure propellant flow at low cost and system mass, with high fail-operational reliability. The RFS functions by storing the liquid propellants in large, low-pressure tanks and then expelling each propellant through two or three small, high-pressure tanks. Each RFS tank is sequentially filled, pressurized, expelled, vented, and refilled so as to provide a constant, or variable, mass flow rate to the engine. This type of system is much lighter than a conventional pressure fed system in part due to the greatly reduced amount of inert tank weight. The delivered payload for an RFS is superior to that of conventional pressure fed systems for conditions of high total impulse and it is competitive with turbopump systems, up to approximately 2000 psi. An advanced version of the RFS uses autogenous pressurization and thrust augmentation to achieve higher performance. In this version, the pressurization gases are combusted in a small engine, thus making the pressurization system, in effect, part of the propulsion system. The RFS appears to be much less expensive than a turbopump system, due to reduced research and development cost and hardware cost, since it is basically composed of small high- pressure tanks, a pressurization system, and control valves. A major benefit is the high reliability fail-operational mode; in the event of a failure in one of the three tank-systems, it can operate on the two remaining tanks. Other benefits include variable pressure and flow rates, ease of engine restart in micro-gravity, and enhanced propellant acquisition and control under adverse acceleration conditions. We present a system mass analysis tool that accepts user inputs for various design and mission parameters and calculates such output values payload and vehicle weights for the conventional pressure fed system, the RFS, the Autogenous Pressurization Thrust Augmentation (APTA) RFS, and turbopump systems. Using this tool, a preliminary design of a representative crew exploration vehicle (CEV) has been considered. The design parameters selected for a representative system were modeled after the orbital maneuvering system (OMS) on the Shuttle Orbiter, with an increase of roughly a factor of ten in the delta- V capability and a greater thrust (30,000 lbs, vs. 12,000 lbs). Both storable and cryogenic propellants were considered. Results show that a RFS is a low mass alternative to conventional pressure fed systems, with a substantial increase in payload capability and that it is weight-competitive with turbopump systems at low engine pressure (a few hundred psi); at high engine pressures, the APTA RFS appears to offer the highest payload. We also present the status of the RFS test bed fabrication, assembly, and checkout. This test bed is designed to provide flow rates appropriate for engines in the roughly 10,000 to 30,000 lb thrust range.

Trewek, Mary↗

Effect of Strict Head Down Tilt Bedrest on Pituitary Gland Height

BACKGROUND Pituitary gland deformity and loss of pituitary height have been identified in astronauts postflight, hypothesized to be related to increased intracranial pressure or intracranial pressure pulsatility exposure from prolonged weightlessness. Microgravity-induced chronic headward fluid shift has been suggested as a root cause of intracranial compliance changes leading to altered intracranial pressure dynamics. Elevated intracranial pressure or pressure pulsatility is theorized to promote the development of an arachnoid diverticulum, which herniates into the pituitary fossa via a defect in the diaphragma sellae compressing the pituitary gland. We aimed to determine if chronic headward fluid induced by strict head-down tilt bed rest (HDTBR) can cause similar quantitative changes in pituitary gland height. METHODS Control group data from two 6-degree HDTBR studies were analyzed (SANS CM and AGBRESA). The AGBRESA study collected MRI data at Baseline, 14 days into HDTBR (HDTBR-14), 52 days into HDTBR (HDTBR-52), and three days into Recovery (R+ 3) and included eight healthy adults (2 women), age = 33 ± 8 years. The SANS CM collected MRI data at Baseline, 15 days into HDTBR (HDTBR-15), 29 days into HDTBR (HDTBR-29), and 12 days into Recovery (R+12) and included twelve healthy adults (4 women), age = 34 ± 9 years. Pituitary gland height was evaluated using a sagittal, 3D T1-MPRAGE sequence obtained on a dedicated 3T Siemens Biograph MRI scanner using a 32-channel head coil. Following the reconstruction of a true orthogonal sagittal plane of the pituitary gland using a 3D multiplanar reconstruction tool (Horosproject.org), the anterior pituitary mid-gland height at the pituitary stalk level was quantified according to the methodology described by Kramer et al. . A paired t-test was used to evaluate changes from the baseline measurements. FINDINGS The mean height of the pituitary gland at baseline was 6.5 ± 1.7 mm (AGBRESA) and 5.7 ± 1.6 mm (SANS CM). From baseline measurements, the SANS CM STUDY data showed a decrease in mean pituitary height of 0.3 mm (p=.011) at HDTBR-15, 0.5 mm at HDTBR-29 (p<.001) and 0.2 mm at R+12 (p=.02). From baseline measurements, the AGBRESA data showed a decrease in mean pituitary height of 0.3 mm (p=.06) at HDTBR-14, 0.6 mm at HDTBR-52 (p<.002) and 0.2 mm at R+3 (p=.13). CONCLUSION HDTBR results in progressive loss of pituitary height, which is most severe with the longest HDTBR exposure. Early pituitary height loss was the same at HDTBR-14 (AGBRESA) and HDTBR-15 (SANS CM). Residual pituitary height loss was the same at R+12 and R+3 but only significant in the latter (SANS CM). The degree of pituitary height loss at HDTBR-52 replicates the 0.6 mm height loss found in long-duration astronauts after approximately six months of microgravity exposure (p<.01, preflight mean height=5.9 mm). The hormonal effects of pituitary height loss are unknown in astronauts and HDTBR subjects and should be investigated in future studies. Future work will examine the individual variability in the loss of pituitary gland height and whether those changes are associated with other SANS findings, such as optic disc edema.

L A Kramer↗

Additive Manufacturing and Experimental Characterization of Nickel-Titanium Shape-Memory Alloy Wick Structures and Heat Pipes for Spacecraft Thermal Control

Shape memory alloys (SMA), such as those based on nickel-titanium (NiTi), are increasingly being applied as multifunctional spacecraft components. For thermal management applications, NiTi flow tubing hinges and self-deploying loop heat pipes have been demonstrated. Emerging additive manufacturing (AM) processes are enabling more complex SMA devices than can be formed from conventional plain wire, tubing, and sheet stock materials. This paper presents our progress toward applying powder bed fusion AM to producing porous NiTi wicks and NiTi-H2O heat pipes, which could be embedded in thermally deploying radiators for spacecraft thermal management. AM near-equiatomic NiTi (55.1 wt% Ni) porous wick specimens were produced with a range of deposition parameters. Transient acetone rate-of-rise experiments were performed to estimate wick permeability (K) and average pore radius (r_pore) values and identify parameter sets with high capillary performance. Surface treatments were evaluated to achieve hydrophilic wick structures. Evaluated treatments included chemical oxide growth with H2O2, oxide and sodium titanate growth with NaOH solution, and ultrasonic cleaning with specialty detergents that can remove hydrocarbon contaminants. The most durable hydrophilic surface conditions were obtained with the NaOH treatment. High performing wick deposition parameters were used to produce a full AM NiTi heat pipe, which was treated with NaOH solution to activate the wick. This heat pipe was operated on a test stand in the inverted configuration (upper evaporator and lower condenser), and demonstrated stable nearly isothermal operation for 150 hrs.

Thermal management↗

Additive Manufacturing and Experimental Characterization of Nickel-Titanium Shape-Memory Alloy Wick Structures and Heat Pipes for Spacecraft Thermal Control

Shape memory alloys (SMA), such as those based on nickel-titanium (NiTi), are increasingly being applied as multifunctional spacecraft components. For thermal management applications, NiTi flow tubing hinges and self-deploying loop heat pipes have been demonstrated. Emerging additive manufacturing (AM) processes are enabling more complex SMA devices than can be formed from conventional plain wire, tubing, and sheet stock materials. This paper presents our progress toward applying powder bed fusion AM to producing porous NiTi wicks and NiTi-H2O heat pipes, which could be embedded in thermally deploying radiators for spacecraft thermal management. AM near-equiatomic NiTi (55.1 wt% Ni) porous wick specimens were produced with a range of deposition parameters. Transient acetone rate-of-rise experiments were performed to estimate wick permeability (K) and average pore radius (r_pore) values and identify parameter sets with high capillary performance. Surface treatments were evaluated to achieve hydrophilic wick structures. Evaluated treatments included chemical oxide growth with H2O2, oxide and sodium titanate growth with NaOH solution, and ultrasonic cleaning with specialty detergents that can remove hydrocarbon contaminants. The most durable hydrophilic surface conditions were obtained with the NaOH treatment. High performing wick deposition parameters were used to produce a full AM NiTi heat pipe, which was treated with NaOH solution to activate the wick. This heat pipe was operated on a test stand in the inverted configuration (upper evaporator and lower condenser), and demonstrated stable nearly isothermal operation for 150 hrs.

Thermal management↗