Electrodialysis operation with buffer solution

A new method for improving the efficiency of electrodialysis (ED) cells and stacks, in particular those used in chemical synthesis. The process entails adding a buffer solution to the stack for subsequent depletion in the stack during electrolysis. The buffer solution is regenerated continuously after depletion. This buffer process serves to control the hydrogen ion or hydroxide ion concentration so as to protect the active sites of electrodialysis membranes. The process enables electrodialysis processing options for products that are sensitive to pH changes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Scientific Investigations on the Chemical Reactivity of Los Alamos Remediated Nitrate Salt Wastes - 16540

The February 14, 2014 release of radioactivity at the Waste Isolation Pilot Plant (WIPP) was the result of runaway thermal reactions that occurred in a TRU waste drum containing nitrate salts remediated using an organic absorbent. Experimental and modeling studies performed at LANL indicate that mixtures of metal nitrate salts (oxidizer) with sWheat Scoop{sup R} organic kitty litter (fuel) create the potential for exothermic chemical reactions. The use of sWheat{sup R} absorbent in the processing of nitrate salt wastes can be pinpointed as the critical processing decision that led to the failure of the breached drum in the WIPP repository. The most plausible scenario is that a production of heat, either from low-level chemical reactions or the growth of natural microbes, in concert with mixed metal nitrate salts, bismuth lined glovebox gloves and/or lead nitrates when combined with the sWheat{sup R} organic kitty litter, generated a series of exothermic reactions that heated and pressurized the drum resulting in the venting of high-temperature gases and radioactive material into the room. Observations and modeling studies indicate that the probability of thermal runaway in another drum has decreased with time since the WIPP event. However, the complexity of the mixtures, ambiguity in procedures such as those used for neutralization, the heterogeneity of the drum contents, and the difficulty of sampling leads to an irreducible level of uncertainty that mandates the exercise of caution in managing RNS wastes. The situation also requires that this waste stream continue to be stored in a temperature-controlled environment and monitored until the waste can be remediated to remove the hazard permanently. We recommend that proposals to treat nitrate salts with organic absorbents of any kind be accompanied by experimental studies to confirm that similarly sensitive mixtures are not inadvertently created over the range of conditions (mixture quantities, moisture content, etc.) anticipated during processing and storage. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Illustration of VERA Capabilities to Model a Typical iPWR SMR

Small modular reactors (SMRs) are being considered by the commercial nuclear power industry as an option for more distributed generation and for replacement of older fossil fuel generating facilities. SMRs are more compact than operating pressurized water reactors (PWRs), producing about 200 MWe as compared to 1000 MWe or higher for their full-sized cousins, and are offered as “expandable” units; that is, their modular design allows the utility to add more units progressively at the same site. In Summer 2014, CASL reported on a progression of demonstrations illustrating VERA’s ability to simulate a typical SMR of the iPWR type, while developing a simple core cycle design for cycle economic studies. The work included development of fuel assembly lattices, 3D single assembly and full core (quarter symmetry) simulations of the proposed core cycle design using the CASL Virtual Environment for Reactor Applications (VERA). The report concluded that it would be difficult for the SMR to operate for the target 1400 EFPD cycle length and that the fuel cost would be on the order of 50% higher as compared with a PWR. Unfortunately, the Reference 4 core cycle design did not include control component management. The iPWR is intended to be operated using the control rods for reactivity control, as opposed to using soluble boron (like most currently operating PWRs), and the introduction of the control rods is expected to affect the length of the cycle. Therefore, this work continues the previous CASL demonstration of VERA capability to simulate a typical iPWR core, including the development of a control component management strategy using the Reference 4 core design and utilizing the soon-to-be released VERA3.3 tools. Note that this study is not intended as a validation study; rather it is merely an illustration of VERA’s capabilities to simulate a typical iPWR. Simulations included two variations on control rod banks – a two-bank scheme and a ten-bank scheme. Both schemes were modelled using the VERA Common Input, and more than six iterations on each control rod scheme were simulated to arrive at a combination of rod banks and insertion depths that provided a core reactivity near the target k eff of 1.000 ± 0.001 (more than 50 cases run) over two calendar months. In particular, VERA was used to determine the hot excess reactivity for the core design with all rods out (ARO), and then iterative simulations with the rod banks inserted to determine the critical control rod bank positions were completed. VERA options to simplify the process were exercised as possible, particularly restart functionality, coupled thermal-hydraulics using the internal T-H solver, xenon, and depletion capability. The fuel shuffling functionality was not exercised, since the iPWR SMR features a once-through cycle. The VERA method of characteristics (MOC) neutronics subcomponent was used to predict power and reactivity with control rod maneuvering, both with and without thermal-hydraulic feedback. The problem was scaled from 35 CPU cores to 3815, effectively demonstrating the solution time with respect to computing capacity. Computer clusters at Oak Ridge National Laboratory, Idaho National Laboratory and Tennessee Valley Authority were used. These studies provide an additional illustration of the application of VERA to a typical iPWR SMR. Reference 4 previously demonstrated that the codes could handle the differences in geometry for the iPWR, and this study expanded the illustration to include control rod management. Further, the work illustrates the need for in-depth simulations to support effective control rod maneuvering for an iPWR and highlights the need for control rod reactivity search capability within VERA. Additionally, the development of a control rod bank reactivity search capability will be extremely useful for not only this application, but also for BWRs as CASL develops BWR capability in Phase 2.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Convergence of sum-up rounding schemes for cloaking problems governed by the Helmholtz equation

In this work, we consider the problem of designing a cloak for waves described by the Helmholtz equation from an integer programming point of view. The problem can be modeled as a PDE-constrained optimization problem with integer-valued control inputs that are distributed in the computational domain. A first-discretize-then-optimize approach results in a large-scale mixed-integer nonlinear program that is in general intractable because of the large number of integer variables that arise from the discretization of the domain. Instead, we propose an efficient algorithm that is able to approximate the local infima of the underlying nonconvex infinite-dimensional problem arbitrarily close without the need to solve the discretized finite-dimensional integer programs to optimality. We optimize only the continuous relaxations of the approximations for local minima and then apply the sum-up rounding methodology to obtain integer-valued controls. If the solutions of the discretized continuous relaxations converge to a local minimizer of the continuous relaxation, then the resulting discrete-valued control sequence converges weakly \(^*\) in \(L^\infty\) to the same local minimizer. These approximation properties follow under suitable refinements of the involved discretization grids. Our results use familiar concepts arising from the analytical properties of the underlying PDE and complement previous results, derived from a topology optimization point of view.

97 MATHEMATICS AND COMPUTING↗

Energy Management Information Systems Cybersecurity Best Practices

Energy management information systems (EMIS) are a broad and rapidly evolving family of tools that monitor, analyze, and control building energy use and system performance. Critical systems are often integrated with or operate on the same networks as EMIS scope systems, necessitating stable, continuous, and secure communication. When connecting EMIS to building automation and utility control systems, there are also many physical assets that could cause harm to the building and its occupants if a malicious act or human error were introduced. It is imperative to ensure all EMIS scope systems are connected securely to the EMIS and do not open vulnerable pathways to other facility networks and operations. The Federal Energy Management Program (FEMP) promotes best practices for impactful utilization of EMIS at federal facilities. This best practice document is part of a series of fact sheets created to help accelerate the market adoption and use of EMIS in the federal sector. It provides an overview of required EMIS cybersecurity standards for compliance and authority to operate along with additional recommendations.

cybersecurity↗

Energy Management Information Systems Cybersecurity Best Practices

Energy management information systems (EMIS) are a broad and rapidly evolving family of tools that monitor, analyze, and control building energy use and system performance. Critical systems are often integrated with or operate on the same networks as EMIS scope systems, necessitating stable, continuous, and secure communication. When connecting EMIS to building automation and utility control systems, there are also many physical assets that could cause harm to the building and its occupants if a malicious act or human error were introduced. It is imperative to ensure all EMIS scope systems are connected securely to the EMIS and do not open vulnerable pathways to other facility networks and operations. The Federal Energy Management Program (FEMP) promotes best practices for impactful utilization of EMIS at federal facilities. This best practice document is part of a series of fact sheets created to help accelerate the market adoption and use of EMIS in the federal sector. It provides an overview of required EMIS cybersecurity standards for compliance and authority to operate along with additional recommendations.

Cybersecurity↗

Screening of Potential Biomass-Derived Streams as Fuel Blendstocks for Mixing Controlled Compression Ignition Combustion

Mixing controlled compression ignition or diesel engines are highly efficient and are likely to continue to be the primary means for movement of goods for many years to come. Low-carbon biofuels have the potential to significantly reduce the carbon footprint of diesel combustion and could potentially have advantageous properties for combustion such as high cetane number and reduced engine out particle emissions. In this study, we developed a list of potential biomass-derived diesel blendstocks. An online database of properties and characteristics of these bioblendstocks was populated with data. Fuel properties were determined by measurement, model prediction, or literature review. Screening criteria were developed to determine if a bioblendstock met the basic requirements for handling in the diesel distribution system and use as a blend with conventional diesel. Criteria included cetane number =40, flashpoint =52 degrees C, and boiling point or final boiling point <338 degrees C. Blendstocks needed to be soluble in diesel fuel, have a toxicity no worse than conventional diesel, and not be corrosive. Additionally, cloud point or freezing point below 0 degrees C was required. This screening produced a list of 27 potential bioblendstocks. Of these candidates, 13 were available commercially or could be synthesized by biofuels production researchers and included 11 nominally pure components and two mixtures. These 13 candidates were then subjected to further study based on how they impact fuel properties upon blending. Blend properties included cetane number, lubricity, conductivity, oxidation stability and viscosity. Results indicate that all thirteen candidates can meet the basic requirements for diesel fuel blending and are likely to reduce particle emissions from diesel combustion.

09 BIOMASS FUELS↗

Advances in understanding hydration of Portland cement

Progress in understanding hydration is summarized. Evidence supports the geochemistry dissolution theory as an explanation for the induction period, in preference to the inhibiting layer theory. The growth of C–S–H is the principal factor controlling the main heat evolution peak. Electron microscopy indicates that C–S–H “needles” grow from the surface of grains. At the peak, the surface is covered, but deceleration cannot be attributed to diffusion control. The shoulder peak comes from renewed reaction of C{sub 3}A after depletion of sulfate in solution, but release of sulfate absorbed on C–S–H means that ettringite continues to form. After several days space becomes the major factor controlling hydration. The use of new analytical technique is improving our knowledge of the action of superplasticizers and leading to the design of molecules for different applications. Atomistic modeling is becoming a topic of increasing interest. Recent publications in this area are reviewed.

36 MATERIALS SCIENCE↗

Full Scale Evaluation of How Task-Based Overview Displays Impact Operator Workload and Situation Awareness When in Emergency Procedure Space

Control room modernization is critical to extending the life of the 99 operating commercial nuclear power plants (NPP) within the United States. However, due to the lack of evidence demonstrating the efficiency and effectiveness of recent candidate technologies, current NPP control rooms operate without the benefit of various newer technologies now available. As nuclear power plants begin to extend their licenses to continue operating for another 20 years, there is increased interest in modernizing the control room and supplementing the existing control boards with advanced technologies. As part of a series of studies investigating the benefits of advanced control room technologies, the researchers conducted an experimental study to observe the effect of Task-Based Overview Displays (TODs) on operator workload and situation awareness (SA) while completing typical operating scenarios. Researchers employed the Situation Awareness Rating Technique (SART) and the NASA Task Load Index (TLX) as construct measures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced Energy Harvesting Control Schemes for Marine Renewable Energy Devices

The Advanced Energy Harvesting Control Schemes for Marine Renewable Energy Devices (Project) investigated, analyzed and modeled advanced turbine control schemes with the objective of increasing the energy harvested by hydrokinetic turbines in turbulent flow. Ocean Renewable Power Company (ORPC) implemented and validated a feedforward controller to increase power capture; and applied and tested the controls on ORPC’s RivGen® Power Systems in Igiugig, Alaska. Assessments of performance improvements were made for the RivGen® in the Igiugig environment and for ORPC’s TidGen® Power System in a reference tidal environment. Annualized Energy Production (AEP) and Levelized Cost of Energy (LCOE) improvements associated with implementation of the recommended control methodology were made for the TidGen® Power System in the DOE reference tidal environment. System Performance Advancement (SPA) goals were selected for the project. SPA targets were to improve Power to Weight Ratio (PWR) and system Availability, with the intention of reducing Levelized Cost of Electricity (LCOE). This project focused primarily reducing in PWR. Reductions in PWR of 25.5% were achieved. Reductions of 20.3% in LCOE were achieved. This project evaluated four types of controllers which were tested in simulation, emulation, a laboratory flume, and the field. The adaptive Kω2 controller performs similarly to the non-adaptive version of the same controller and may be useful in tidal channels where the mean velocity is continually evolving. Trends in simulation were largely verified through experiments, which also provided the opportunity to test assumptions about turbine responsiveness and control resilience to varying scales of turbulence. Laboratory experiments provided an essential stepping stone between simulation and implementation on a field-scale turbine. Experiments also demonstrated that using “energy loss” as a metric to differentiate between well-designed controllers operating at an optimal tip-speed ratio set-point is difficult, which anticipated the outcome from field experiments. The clear message is that the feedforward Kω2 controller out-performs the feedback controllers in almost all aspects and modes of evaluation. The controllers proved a substantial improvement over the baseline performance of the TidGen® turbine, in terms of energy capture. The effects of noise-contaminated angular velocity signals were investigated and validated by simulation as an explanation for the performance limitations observed for TidGen® turbine operations in Eastport, Maine. Measurements of loads performed as part of the laboratory testing indicate that there are limited differences in average axial thrust force between control architectures. This suggests that none of the control strategies are likely to substantially affect loads on the turbine support structure. Velocity measurements during the ORPC RivGen® turbine deployment at Igiugig, Alaska, in 2014 were used to assess the variability of the river flow. Results suggest that the river flow is approximately steady, in the mean sense, at any particular location in the river, with random turbulent fluctuations that are around 10% of the mean flow. The mean flow in the center channel of the river is 2.5 m/s, with reductions near the riverbanks and in the shallows. Spectral analysis and lagged correlation results indicate that temporal fluctuations at a given point are dominated by large scale fluctuations, such that measurements at the turbine location are just as useful for inflow control implementation as upstream measurements. At this site, and likely at many other river sites, flow is generally steady at a given location, but flow varies dramatically between locations, particularly laterally across the river. The primary result is that a lateral change in position of a few meters results in changes to flow speed that far exceed the turbulence fluctuations at any given location. The turbulence is dominated by long time scales. Following final system tests, the RivGen® device was submerged and each evaluated controller was tested across a range of gain/set point values and filter configurations for a minimum of 5 minutes, with longer runs attempted for well-performing cases. In addition to testing controllers during the 2015 deployment season, LGL Alaska Research Associates Inc. (LGL) performed a fish monitoring study in compliance with Alaska Department of Fish and Game fisheries habitat permit for the project. During the season, LGL reviewed 10% of 179 one-hour blocks of footage (6 minutes on the hour) and documented a total of over 1200 fish in the vicinity of the RivGen® device, including over 800 salmon smolt and over 350 adult salmon. No evidence of adverse effects including passage delay by upstream migrating salmon was noted. This is an important result for future deployments and has a direct impact on commercial system designs.

16 TIDAL AND WAVE POWER↗

Real-Time Control of an Ensemble of Heterogeneous Resources

This paper focuses on the problem of controlling an ensemble of heterogeneous resources connected to an electrical grid at the same point of common coupling (PCC). The controller receives an aggregate power setpoint for the ensemble in real time and tracks this setpoint by issuing individual optimal setpoints to the resources. The resources can have continuous or discrete nature (e.g., heating systems consisting of a finite number of heaters that each can be either switched on or off) and/or can be highly uncertain (e.g., photovoltaic (PV) systems or residential loads). A naive approach would lead to a stochastic mixed-integer optimization problem to be solved at the controller at each time step, which might be infeasible in real time. Instead, we allow the controller to solve a continuous convex optimization problem and compensate for the errors at the resource level by using a variant of the well-known error diffusion algorithm. We give conditions guaranteeing that our algorithm tracks the power setpoint at the PCC on average while issuing optimal setpoints to individual resources. We illustrate the approach numerically by controlling a collection of batteries, PV systems, and discrete loads.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Tunable graphene-based infrared reflectance filter having patterned nanoantenna layer and unpatterned graphene layer

An actively tunable optical filter can control the amplitude of reflected infrared light. The filter exploits the dependence of the excitation energy of plasmons in a continuous and unpatterned sheet of graphene, on the Fermi-level, which can be controlled by conventional electrostatic gating. An exemplary filter enables simultaneous modification of two distinct spectral bands whose positions are dictated by the device geometry and graphene plasmon dispersion. Within these bands, the reflected amplitude can be varied by over 15% and resonance positions can be shifted by over 90 cm−1. Electromagnetic simulations verify that tuning arises through coupling of incident light to graphene plasmons by a nanoantenna grating structure. Importantly, the tunable range is determined by a combination of graphene properties, device structure, and the surrounding dielectrics, which dictate the plasmon dispersion. Thus, the underlying design is applicable across a broad range of infrared frequencies.

Beechem, III, Thomas Edwin↗

Inspection Report on "Internal Controls over Accountable Classified Removable Electronic Media at Oak Ridge National Laboratory"

The Department of Energy's Oak Ridge National Laboratory (ORNL) conducts cutting edge scientific research. ORNL utilizes removable electronic media, such as computer hard drives, compact disks, data tapes, etc., to store vast amounts of classified information. Incidents involving breakdowns in controls over classified removable electronic media have been a continuous challenge for the Department. The loss of even one piece of such media can have serious national security implications. In 2004, the Department had a complex-wide 'stand-down' of all activities using classified removable electronic media, and such media containing Secret/Restricted Data or higher classified data was designated 'Accountable Classified Removable Electronic Media' (ACREM). As part of the stand-down, sites were required to conduct a 100 percent physical inventory of all ACREM; enter it all into accountability; and conduct security procedure reviews and training. Further, the Department implemented a series of controls, including conducting periodic inventories, utilizing tamper proof devices on ACREM safes, and appointing trained custodians to be responsible for the material. After performance testing and validation that the required accountability systems were in place, ACREM operations at ORNL were approved for restart on August 10, 2004. We conducted a review at ORNL and associated facilities to determine whether ACREM is managed, protected, and controlled consistent with applicable requirements. We found that: (1) Eight pieces of Secret/Restricted Data media had not been identified as ACREM and placed into a system of accountability. Consequently, the items were not subject to all required protections and controls, such as periodic accountability inventories, oversight by a trained custodian, or storage in a designated ACREM safe. (However, the items were secured in safes approved for classified material.) (2) Other required ACREM protections and controls were not implemented as follows: a tamper indicating device was not being used on an ACREM safe; records documenting when a certain safe was opened did not support that a purported inventory had been conducted; and a safe inventory had not been completed in a timely manner. (3) A Personal Digital Assistant and a thumb drive, both capable of recording or transmitting data, were stored in a security area without an analysis to identify vulnerabilities and compensatory measures having been conducted, as required. We also found that an ORNL Cooperative Research and Development Agreement partner had not disabled classified computer ports at the partner's site that were capable of writing classified information to external or removable media, as required. We made several recommendations designed to enhance the security of ACREM, security areas, and computers.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Non-Uniform Dose Mapping Controlled by Modulated Vertical and Horizontal Scans

Since geometries of semi-conductor devices continue to shrink, the requirement for each process becomes severer to keep uniformity of electrical parameters of the semi-conductor devices. A larger wafer also causes larger variations. Thus it has been strongly required for ion implantation process to compensate for the variations from other processes because of its good dose controllability. A newly developed mapping of intentional non-uniform dosage system, which is named 'MIND system', is implemented in SEN's single-wafer-type implanters. The MIND system controls both horizontal and vertical scan speed simultaneously. Intentional two-dimensional non-uniform profiles of sheet resistance, such as concentric and eccentric profiles, are obtained only by single-step ion implantation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DCA++: A software framework to solve correlated electron problems with modern quantum cluster methods

We present the first open release of the DCA++ project, a high-performance research software framework to solve quantum many-body problems with cutting edge quantum cluster algorithms. DCA++ implements the dynamical cluster approximation (DCA) and its DCA extension with a continuous self-energy. The algorithms capture nonlocal correlations in strongly correlated electron systems, thereby giving insight into high-$T_c$ superconductivity. The code’s scalability allows efficient usage of systems at all scales, from workstations to leadership computers. With regard to the increasing heterogeneity of modern computing machines, DCA++ provides portable performance on conventional and emerging new architectures, such as hybrid CPU–GPU, sustaining multiple petaflops on ORNL’s Titan and CSCS’ Piz Daint supercomputers. Moreover, we show how sustainable and scalable development of the code base has been achieved by adopting standard techniques of the software industry. These include employing a distributed version control system, applying test-driven development and following continuous integration.

97 MATHEMATICS AND COMPUTING↗

Energy storage connection system

A power system for connecting a variable voltage power source, such as a power controller, with a plurality of energy storage devices, at least two of which have a different initial voltage than the output voltage of the variable voltage power source. The power system includes a controller that increases the output voltage of the variable voltage power source. When such output voltage is substantially equal to the initial voltage of a first one of the energy storage devices, the controller sends a signal that causes a switch to connect the variable voltage power source with the first one of the energy storage devices. The controller then causes the output voltage of the variable voltage power source to continue increasing. When the output voltage is substantially equal to the initial voltage of a second one of the energy storage devices, the controller sends a signal that causes a switch to connect the variable voltage power source with the second one of the energy storage devices.

25 ENERGY STORAGE↗

Autonomous Tools for Attack Surface Reduction (Final Report)

The electric power grid is a complex critical infrastructure that forms the lifeline of modern society, and its secure and reliable operation is of paramount importance to national security and economic wellbeing. However, recent findings documented in authoritative sources indicate the threat of cyber-based attacks growing in numbers and sophistication. However, securing the grid against stealthy cyberattacks is a challenging task due to legacy nature of the infrastructure coupled with dynamic nature of threat landscape and ever-growing sophistication of the adversaries. Additionally, the grid’s attack surface continues to grow with the increased dependence on digital communications and control that now extends to each consumer through smart meters and distributed energy resources. Unfortunately, this expansive surface increases the grid’s vulnerability and further exposes critical control systems in both substations and control centers. To respond to this emerging need, we had successfully assembled an interdisciplinary team with academic- industry partnership to successfully conduct research, development, evaluation, demonstration, and commercialization of attack surface reduction tools, whose goal was to significantly reduce the cyber attack surface in the North American power grid. Our proposed project was a synergistic collaborative effort leveraging the synergistic expertise of the team members across power systems, cyber security and CPS security, testbeds, field deployments and demonstration, and successful commercialization. The following are the specific tasks that have been successfully completed two phases (2016-2020). Phase I: Task 1: Developed and implemented a robust Project Management and Data Management Plan, coupled with a well thought out Risk Mitigation Plan. Task 2.1: Developed a comprehensive framework that continually assesses and autonomously reduces the attack surface for the power grid control environment spanning across substations, control center and the SCADA network to significantly reduce the risks of cyber attacks. Task 2.2: Developed attack surface analysis techniques, metrics, and tools that assess the attack surface at multiple levels including the control center, substations, and the SCADA network. Task 2.3: Developed attack surface reduction techniques and tools that dynamically reduce attack surface and hence increase attacker’s cost without interfering in the critical functions of the system. Task 2.4: Prototyped, implemented, and quantitatively evaluated/validated the techniques and tools on a realistic industrial CPS security testbed environment by leveraging the unique resources of the team. Task 3: Developed Commercialization plan to transition the developed tools into power system industry stakeholders for a broader adoption by leveraging the expertise of our industrial members. Phase II: Task 4: Successfully completed field demonstration, verification, and evaluation of the effectiveness of the attack surface analysis and reduction techniques on a realistic utility testbed environment. This also involved the development of realistic scenarios, sound metrics, data sets, evaluation criteria, and documentation. Technology integration & Field demonstration: The project had significantly advanced the state-of-the-art research and practice in improving the cybersecurity of our nation’s power grid infrastructure against cyber threats. In particular, the proposed, designed, and deployed attack surface analysis and reduction algorithms and tools have contributed to significantly reducing the exposure and risk of the devices, substations, and the integrated SCADA/EMS/ DMS grid environment to cyber threat. Strong demonstration and evaluation techniques have verified the feasibility of the developed techniques on realistic cyber-physical testbeds and utility partner's real grid environment, and collaborative research and evaluation of attack surface reduction techniques (for wide-are monitoring and control) within a vendor (GE) EMS platform. The Attack Host Analyzer (AHA) tool that was developed through this project was made available through GitHub.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Smart Ventilation for Advanced California Homes – Single Zone Technology Task

This study is intended to demonstrate the potential for energy savings while providing acceptable Indoor Air Quality (IAQ) for ZNE homes. It uses the concept of Smart Ventilation where ventilation systems are designed and controlled to produce the same, or better, IAQ compared to simple, continuously operated ventilation systems. The key energy saving principle for smart ventilation is that ventilation is shifted in time to when the energy required to condition the air is lower. A variety of smart ventilation controls based on outdoor temperature, occupancy and auxiliary fan sensing were developed and assessed across homes built to the 2016 Title 24 Prescriptive standards in California climate regions. Simulations used a co-simulation strategy that combines EnergyPlus with CONTAM. The IAQ calculations were based on the equivalent ventilation principle outlined in the ASHRAE 62.2-2016 ventilation standard, Appendix C. Two prototype homes were simulated (1-story 2,100 ft2 and 2-story 2,700 ft2). Their envelope airtightness was varied between 1, 3 and 5 ACH50. Climate zones were chosen to reflect the variety of heating and cooling demand throughout California. A weighted average analysis was used to generalize the energy predictions across the projected new housing stock in the state. Temperature-based controls were found to be effective, with the most successful smart controls reducing weighted average site ventilation energy use by about 40%, while TDV weighted average ventilation energy reductions were higher, up to roughly 60%. Results were also normalized to ensure identical IAQ in all cases, and the weighted average site and TDV ventilation savings increased, up to 55% and 72% ventilation savings, respectively, for the top-performing temperature-based controls. Peak demand during the 2-6pm period on the hottest days of the year was reduced by up to 400 watts. More than 90% of site energy savings were for heating end-uses, while TDV energy savings were split fairly evenly between heating and cooling. On average, the smart controls reduced occupant pollutant exposure by 0-10%, and they increased ventilation rates by roughly 20%. Occupancy-based controls that accounted for contaminants released by building materials and furnishings during unoccupied times were generally ineffective, with very low energy savings. Performance was improved somewhat through use of a 1-hour pre-occupancy flush out period, though savings were still marginal compared to temperature-based controls. All temperature and occupancy controls were also tested with auxiliary fan sensing capability (i.e., accounting for the use of other exhaust devices in the home, like bathroom or kitchen fans). Auxiliary fan sensing increased energy savings in all cases, from roughly 5 to 15%.

42 ENGINEERING↗