Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “consumption potential”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Combined Land Use of Solar Infrastructure and Agriculture for Socioeconomic and Environmental Co-Benefits in the Tropics

Solar photovoltaics (PV) are on the rise even in areas of low solar insolation. However, in developing countries with limited capital, land scarcity, or with geographically isolated agrarian communities, large solar infrastructures are often impractical. In these cases, implementation of low-density PV over existing crops may be required to integrate renewable energy services into rural communities. Here, using Indonesia as a model system, we investigated the land use, energy, greenhouse gas emissions, economic feasibility, and the environmental co-benefits associated with off-grid solar PV when combined with high value crop cultivation. The life cycle analyses indicate that small-scale dual land-use systems are economically viable in certain configurations and have the potential to provide several co-benefits including rural electrification, retrofitting diesel electricity generation, and electricity for processing agricultural products locally. A hypothetical full-density off-grid solar PV for a model village in Indonesia shows that electricity output (1907.5 GJ yr-1) is much higher than the total residential consumption (678 GJ yr-1), highlighting the opportunity to downscale the PV infrastructure by half to lower capital cost, to co-locate crops, and to support secondary income generating activities. Economic analysis shows that the 30-year net present cost of electricity from the half-density co-located PV system (12,257 million IDR) is significantly lower than that of the flat cost of diesel required to generate equivalent electricity (14,702 million IDR). Our analysis provides insights for smarter energy planning by optimizing the efficiency of land use and limiting conversion of agricultural and forested areas for energy production.

agrivoltaics↗

Coupling Waste Feedstocks to Microbial Protein Production in a Circular Food System

Global food production is a major contributor to greenhouse gas emissions, water consumption, and land use. As an alternative to conventional agriculture, the production of waste-derived microbial protein (MP) holds promise for reducing environmental impacts. MP can be mass-produced in volumetrically scalable fermentation processes on short time scales, enabling facile scale-up with lower greenhouse gas emissions, land use, and water impacts than animal and, in some cases, plant protein. MP can also be produced from waste feedstocks, diverting waste from landfills or the natural environment. This Perspective explores the availability and suitability of waste feedstocks for MP production, suggesting that MP generated from waste feedstocks in the United States could fulfill twice the current national protein demand. Here, we also discuss the biotechnological and separations processes required to produce food-grade MP for human consumption from waste. Key challenges include MP consistency, consumer and regulatory acceptance, and the process utilities (electricity, heat, and nutrients) that account for up to 85% of MP costs and most environmental impacts, all of which present opportunities for innovation in the microbiology and process design spaces. Overall, this work highlights the potential of MP to contribute to a more circular, resilient, and sustainable food system.

09 BIOMASS FUELS↗

Latent demand for electricity in sub-Saharan Africa: A review

Universal access to electricity is an essential part of sub-Saharan Africa's path to development. With the United Nations setting Goal 7 of its sustainable development goals to be universal access to clean, reliable and affordable electricity, substantial research efforts have been made to optimize electricity supply based on projected demand in sub-Saharan African (SSA) countries. Our study reviews the literature on electricity demand, with a specific focus on latent demand (i.e., electricity demand that would exist if the necessary techno-economic conditions were met) in SSA. We found that out of 57 electricity demand papers reviewed, only 3 (5%) incorporated latent demand in their electricity demand projections. Furthermore, majority of the literature on electricity consumption and demand estimation in SSA use econometric models to identify determinants of electricity consumption and project future demand. We find that population density, urbanization, household income, electricity price, market value of crops and availability of natural resources to be significant determinants of electricity consumption in SSA. We conclude the review by proposing a methodology, and providing an initial proof of concept, for more accurately projecting latent demand in sub-Saharan Africa. Incorporating latent demand in electrification models would help inform energy sector stakeholders (e.g., investors and policymakers) about which sectors and geographic locations hold potential for wealth creation via electricity access.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Hydrogen Infrastructure Analysis for the Port Applications [Slides]

The International Maritime Organization has committed to 50% reduction in GHG emissions by 2050 worldwide as of 2023. This analysis includes performing an inventory and modeling efforts to understand the energy, equipment and cost requirements to support decarbonization of cargo handling and shore power at U.S. Ports, along with assessment of zero- and near- zero emission fuel supplies at or near U.S. ports focused upon Hydrogen technologies. Initial market assessment for ocean going vessels for harbor support and ocean-going vessels is explored. An energy analysis is performed on the port system using a holistic approach and considering the port as an entire ecosystem that functions as a transportation and energy node. Presently, a comprehensive view is lacking for future analysis efforts, this analysis seeks to address this gap in data by evaluating four representative port types and the potential for utilizing hydrogen for the maritime industry. Every port is different, but broadly they could be bracketed into reference cases with scaling factors for the relative size of the port operations. These reference ports are for future use, potentially as baselines for analysis and development of demonstration programs. An equipment inventory for each reference port type (container, bulk, breakbulk, and inland waterway) is presented. A comparative analysis of fuel cell electric and battery electric equipment is conducted based on the following criteria: technology readiness level, refueling/charging time, operational range, energy consumption, and fuel cost savings compared to baseline internal combustion engine equipment. The tradeoffs and synergies between two alternative powertrains is highlighted. Based on energy and infrastructure analysis, average and high equipment utilization profiles across different port types is identified and quantified baseline fuel and electricity demand for various decarbonization scenarios. Based on the portfolio of equipment converted to fuel cell electric, the estimates of initial capital investment are provided for hydrogen refueling stations across ports. An energy demand model is developed that predicts well the all-electric cargo handling equipment annual energy consumption for ports with annual tonnage under 2 million twenty-foot equivalent units (TEUs). The model is a good rubric to follow for further energy demand models that can create a scalable solution to understand the energy needs of cargo handling equipment, whether they are all-electric, hydrogen fuel cell, or powered by another fuel-type. Zero and near-zero emission fuel supply at ports is evaluated looking into the characteristics of hydrogen, ammonia, and methanol as an alternative fuel, as well as the bunkering status. The readiness of reference ports to produce ammonia or methanol and bunker the fuel is examined based on the framework developed by the Global Maritime Forum and Rocky Mountain Institute.

08 HYDROGEN↗

Ferrocene Bis(Sulfonate) Salt as Redoxmer for Fast and Steady Redox Flow Desalination

Desalination is considered a promising solution to alleviate water shortages, yet current methods are often restricted, due to challenges like high energy consumption, significant cost, or limited desalination capacity. In this study, we present a novel approach of redox flow desalination (RFD) utilizing the highly aqueous-soluble and reversible redox-active compound, potassium 1,1'-bis(sulfonate) ferrocene (1,1'-FcDS). This water-soluble organic compound yielded stable and rapid desalination, sustaining extended operation without notable decay and achieving an impressive desalination rate of up to 457.5 mmol·h -1 ·m -2 and energy consumption as low as 40.2 kJ·mol NaCl -1 . Specifically, the RFD device effectively desalinated a 50 mM NaCl solution to potable standards within 6000 s using 1,1'-FcDS. It maintained an average energy consumption of 178.16 kJ·mol NaCl -1 and exhibited negligible deterioration in desalination rate, energy efficiency, and charge efficiency throughout a rigorous 12,000 s cycling test. Furthermore, the versatility of this method was demonstrated by effectively treating saline water with varying initial concentrations from 10 mM to 50 mM, showcasing its potential across a broad spectrum of applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Non-invasive (non-contact) measurements of human thermal physiology signals and thermal comfort/discomfort poses -A review

Heating, ventilation and air-conditioning (HVAC) systems have been adopted to create comfortable, healthy and safe indoor environments. In the control loop, the technical feature of the human demand-oriented supply can help operate HVAC effectively. Among many technical options, real time monitoring based on feedback signals from end users has been frequently reported as a critical technology to confirm optimizing building performance. Recent studies have incorporated human thermal physiology signals and thermal comfort/discomfort status as real-time feedback signals. A series of human subject experiments used to be conducted by primarily adopting subjective questionnaire surveys in a lab-setting study, which is limited in the application for reality. With the help of advanced technologies, physiological signals have been detected, measured and processed by using multiple technical formats, such as wearable sensors. Nevertheless, they mostly require physical contacts with the skin surface in spite of the small physical dimension and compatibility with other wearable accessories, such as goggles, and intelligent bracelets. Most recently, a low cost small infrared camera has been adopted for monitoring human facial images, which could detect the facial skin temperature and blood perfusion in a contactless way. Also, according to latest pilot studies, a conventional digital camera can generate infrared images with the help of new methods, such as the Euler video magnification technology. Human thermal comfort/discomfort poses can also be detected by video methods without contacting human bodies and be analyzed by the skeleton keypoints model. Here, new sensing technologies were summarized, their cons and pros were discussed, and extended applications for the demand-oriented ventilation were also reviewed as potential development and applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Durability enhancement of all-solid-state electrochromic devices by adjusting the charge density ratio between electrochromic and counter electrode layers

Here, owing to an increase in global warming, smart-window devices based on charge-balanced electrochromic devices (ECDs), which exhibit high potential to increase the thermal efficiency of buildings, have gained prominence. However, studies on the fabrication and cycling stability of charge-balanced ECDs are scarce. In this study, WO 3 and NiO x films were deposited on indium-tin-oxide (ITO)-coated glass substrates by reactive direct-current magnetron sputtering, and the deposition time was varied to control the thickness and charge density of the thin films. Subsequently, the NiO x /ITO/glass and WO 3 /ITO/glass substrates were laminated with a Li-based polymeric electrolyte to fabricate all-solid-state ECDs comprising electrochromic (EC) and counter-electrode (CE) layers in charge-density ratios of 12.6, 6.4, 2.3, and 1.1. Changes in the electrochromic properties, device-layer microstructure, crystal structure, and elemental composition of the as-constructed ECDs before and after degradation were investigated to understand the influence of the charge-density ratio of the EC and CE layers on the long-term durability of ECDs. Increasing the charge-density ratio decreased the cycling stability of the device owing to changes in the microstructure and crystal structure of the NiO x layer in the microstructural deep-trap sites. Among all the ECDs, those comprising EC and CE layers with similar charge densities showed the most stable optical modulation and highest long-term durability. Finally, based on the aforementioned results, a degradation mechanism for charge-imbalanced all-solid-state ECDs was proposed. This study is expected to open new frontiers in designing optimal-performance electrochemical devices with a wide variety of potential applications.

14 SOLAR ENERGY↗

Performance of Windows in Walls With Continuous Insulation

Window openings in walls are a significant contributor to poor thermal performance because of thermal bridging through the framing members (e.g., studs, joists, plates, bracing) and because windows lack the thermal properties of insulation. Window installation guidance for walls with continuous insulation (CI) is critical for continued market growth of this energy efficiency technology. This research project offers window manufacturers a starting point and a potential path toward developing installation instructions for windows over CI. The objectives of the research include evaluating the common method for installing windows in walls with CI, as well as establishing acceptance criteria for evaluating the performance of windows installed in walls with and without CI. The research measures: 1. The performance characteristics (e.g., water management, structural integrity) of windows in walls without CI. 2. The performance of different thicknesses and types of CI used in walls. 3. The performance of different types of window assemblies (e.g., double-hung windows, mulled double-hung windows, mulled casement windows, and slider windows) installed over CI. 4. The performance of window flange types (e.g., rigid mounting and less robust flanges) installed over CI. 5. Installing windows over CI using baseline installation instructions versus window manufacturer installation instructions. The project’s sequential testing protocol consists of the following: • A water penetration resistance testing adapted from two ASTM standards: E331 (uniform static air pressure in four steps) and E547 (cyclic static air pressure) • A temperature cycling adapted from ASTM E2264 Method B (convective hot air) • A service condition wind loading test adapted from ASTM E330 • A six-month vertical displacement observation phase prior to the structural performance testing • A final water penetration resistance test after vertical displacement observation • A structural performance test adapted from ASTM E330. Key research findings include: • The criterion for passing a water penetration resistance test is that there is no water overflowing at the interior face of the studs. If there is any bubbling or slight pooling of water at the sill, then it must recede after the pressure is removed. Excessive leakage and/or water leaking to the interior face of the framing around the window constitutes a failure. • All single double-hung windows installed directly to lumber or over oriented strand board passed all test protocols. • For most wall specimens, the test results showed that the use of foam sheathing did not affect the performance of the window for water leakage. • All wall specimens underwent temperature cycling. The results indicated that temperature cycling had little to no effect on windows installed over foam sheathing. • For wall specimens that underwent six-month vertical displacement monitoring, the results showed that windows installed over foam sheathing do not sag over time. • The single-hung and double-hung windows installed using window manufacturer installation instructions passed the structural performance test, compared to failures observed in windows that were installed using generic installation instructions. The generic and manufacturer installation methods differed on the following construction details: type of fasteners, fastening patterns on the flanges, and window shimming details. • Additional testing is required to determine methods to improve structural pressure performance of slider windows. Potential solutions that would require additional testing may include fastener spacing, different types of fasteners, masonry window clips, construction adhesive, foam sealant, stronger window flange material, and/or straps.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integrated Spatial, Spectral, & Temporal Optical Reflectance System for Precision Occupancy & Location Sensing to Improve Building Energy Efficiency

Buildings consume approximately 35% of the electricity used in the U.S. and building owners can significantly reduce this energy use by providing services like heating, electrical power and lighting only when people are present. The ARPAe funded program titled “INTEGRATED SPATIAL, SPECTRAL, & TEMPORAL OPTICAL REFLECTANCE SYSTEM FOR PRECISION OCCUPANCY & LOCATION SENSING TO IMPROVE BUILDING ENERGY EFFICIENCY” demonstrates how a low cost sensor technology developed for measuring distances can be used to count and locate occupants with a high degree of precision with a very low error rates. This platform tells a building control system where occupants are located (but not who they are) so that energy consuming services can be provided only when the services are needed by building occupants. The original proof of concept involved using low cost, commercially available time-of-flight (TOF) sensors that measure distance, but the performance of these existing sensors was lacking, as they could not operate properly in the presence of sunlight, which blinded the simple TOF sensors and limited their utility in buildings. This project proposed a powerful new class of TOF sensors that used state-of-the-art integrated circuit (IC) fabrication processes that combined advanced photonics with conventional silicon chip circuitry for improved sensor performance. An equally important part of this project was to find ways to maximize occupant count and location accuracy while using the fewest number of sensors possible, in order to keep costs low. By using building blueprints to create digital twins of commercial building spaces, the team developed new algorithms to maximize occupant count and tracking accuracy by properly locating the minimum number of sensors at just the right spots in the building. This capability not only minimizes system costs but also simplified sensor installation and system commissioning. Our simulations of our sensor networks for a range of commercial floorplan designs demonstrated that our installed cost target of $0.08/sqft was attainable, though not fully demonstrated during the project. Finally, we noted that the TOF sensor concept could provide a valuable role in health and eldercare by tracking patients without the need for worn sensors and would be useful for fall detection and other patient safety metrics, including tracking healthcare/patient interactions. We feel that, when fully developed, this new class of sophisticated TOF sensors and support software will be a powerful new approach to improving building energy efficiency based on occupant centric control platforms and will also open new levels of patient safety in healthcare operations. To realize this potential, the team formed the Troy Sensor Company LLC to oversee licensing of the programs patents and continue to seek commercialization of this program’s activity sensing technologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High Aspect Ratio OLEDs

Long-term reliability is especially challenging for organic light emitting diodes (OLEDs) used in solid-state lighting applications because OLED lifetime is inversely proportional to luminance, and most lighting applications demand high luminance. This project explored a new strategy to overcome this tradeoff by constructing OLEDs on a substrate with sub-mm, high aspect ratio surface texture. By creating more active OLED area per unit lighting panel area, the device current density required to generate a given panel luminance decreases. We validated this approach for both fluorescent and phosphorescent OLEDs, demonstrating good thickness uniformity on corrugated substrates with area enhancement factors up to 1.4x using a standard thermal evaporator. Relative to planar controls at the same panel current density, the high aspect ratio devices achieve a 2.7-fold increase in operating lifetime and up to a 40% increase in external light extraction efficiency. Experiments carried out on a pilot-line OLED manufacturing system demonstrated good coating uniformity, indicating that this approach has the potential to be implemented at scale and therefore offers a powerful pathway to improve the efficiency and lifetime of OLED lighting.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Technical Assistance for the Makah Tribe, Washington

The Energy Technology Innovation Partnership Project (ETIPP) worked with the Makah Tribe on strategic energy planning, including scoping future energy needs of relocated facilities, understanding the potential for new energy generation options to support current and future energy demand, and supporting communication and capacity-building goals.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Contrasting effects of glutamate and branched-chain amino acid metabolism on acid tolerance in a Castellaniella isolate from acidic groundwater

Groundwater acidification co-occurring with nitrate pollution is a common, global environmental health hazard. Denitrifying bacteria have been leveraged for the in situ removal of nitrate in groundwater. However, co-existing stressors—such as low pH—reduce the efficacy of biological removal processes. Castellaniella sp. str. MT123 is a complete denitrifier that was isolated from acidic, nitrate-contaminated groundwater. The strain grows robustly by nitrate respiration at pH < 6.0, completely reducing nitrate to dinitrogen gas. Genomic analyses of MT123 revealed few previously characterized acid tolerance genes. Thus, we utilized a combination of proteomics, metabolomics, and competitive mutant fitness to characterize the genetic mechanisms of MT123 acclimation to growth under mildly acidic conditions. We found that glutamate accumulation is critical in the acid acclimation of MT123, possibly through consumption of intracellular protons via glutamate decarboxylation to GABA. This is despite the fact that MT123 lacks the canonical glutamate decarboxylase-glutamate/GABA antiporter system implicated in acid tolerance in other bacteria. In contrast, branched-chain amino acid (BCAA) accumulation was detrimental to cell growth at lower pHs, possibly through indirect mechanisms impacting the cellular glutamate pool. Genetic analysis previously linked MT123 to a population of Castellaniella that bloomed—concurrent to nitrate removal—during a biostimulation effort to reduce groundwater nitrate concentrations at MT123’s location of origin. Thus, our analyses provide novel insight into mechanisms of acclimation to acidic conditions in a strain with significant potential for nitrate bioremediation.

59 BASIC BIOLOGICAL SCIENCES↗

Trace levels of PtRu on NiMo foam electrodes towards hydrogen evolution reaction

Electrochemical water splitting plays a critical role in high purity hydrogen production. To lower capital cost and energy consumption, efficient catalysts are required to boost the hydrogen evolution reaction (HER), especially in alkaline media. Although PtRu alloy materials are still considered the state-of-the-art catalyst for the HER under alkaline media, large-scale application is hindered by its scarcity and high cost. NiMo alloy catalysts can be potential Pt-free alternatives to drive the sluggish kinetics of the HER under alkaline media, but their HER activity is still not ideal due to the limitation of Volmer step. Herein, we investigated the impact of trace levels of PtRu catalysts on NiMo electrodes towards the HER by incorporating advantages of both PtRu and NiMo catalysts to minimize cost and maintain a promising HER activity. Trace levels of PtRu catalysts from 0.0173 to 0.2648 mg cm −2 were loaded on commercial NiMo foam electrodes by a facile electrodeposition technique utilizing ppm concentration levels of PtRu in electrolyte. The results show that 0.0173 mg cm −2 PtRu loading on NiMo electrode can significantly enhance HER activity compared to the pristine NiMo foam electrode (Tafel slopes drop from ∼170 to ∼60 mV dec −1 ) due to the remarkable decline of energy barriers towards water dissociation and hydrogen adsorption. Meanwhile, the rate determining step (RDS) switches from the Volmer step to the Heyrovsky step when the PtRu loading increases to 0.0675 mg cm −2 . Promising catalytic stability is observed at 100 mA cm −2 over the course of 50 h with a PtRu loading of 0.1198 mg cm −2 . In conclusion, this work demonstrates a potential strategy to decrease the cost and simultaneously maintain superior HER performance by integrating trace levels of PtRu catalyst with NiMo foam electrodes.

Electrochemical water splitting↗

A Critical Exploration of the Efficiency Impacts of Demand Response From HVAC in Commercial Buildings

Increasing quantities of renewable energy generation has yielded a need for greater energy storage capacity in power systems. Thermal storage in variable air volume (VAV) heating, ventilation, and air conditioning (HVAC) in commercial buildings has been identified as an inexpensive source of grid storage, but the true costs are not known. Recent literature explores the inefficiency associated with providing grid services from these HVAC-based demand response (DR) resources by employing a battery analogy to calculate round-trip efficiency (RTE). Results vary significantly across studies and in some cases reported efficiencies are strikingly low. This article has three objectives to address these prior results. First, we synthesize and expand on insights into existing literature by systematically exploring the potential causes for the discrepancies in results. We reinforce previous work indicating baseline modeling may drive differences across studies and deduce that control accuracy plays a role in the major differences between experiments and simulation. Second, we discuss why the RTE metric is problematic for DR applications, discuss another proposed metric, additional energy consumption (AEC), and propose an extension, which we call uninstructed energy consumption (UEC), to evaluate DR performance. Finally, we explore the merits of different metrics using experimental data and highlight UEC's reduced sensitivity to the characteristics of the DR signal than previously proposed metrics.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Variable Frequency Drive (VFD): Emphasizing Energy Savings and Efficiency in Industrial Applications

This project explores the energy saving potential of using a VDA in an industrial pumping application. A 24-horsepower pump, 3-phase centrifugal pump powered by 480V AC supply analyzed under variable frequency control using an ABB ACS880-31-052A-5 VFD. by modulating the motor speed between 30Hz and 60Hz, the VFD enables precise control of power consumption based on system set speed. The article is intended for public cause of the poster session and presentation session. INL/Exp-25-86570

99 - GENERAL AND MISCELLANEOUS↗

Cellular Shade Energy Savings in a Commercial Setting

Windows cause approximately 1.7 quad of heating and cooling energy consumption in the United States. This energy consumption can be reduced by using high-efficiency window attachments. Common Venetian blinds and planar shades, such as roller shades, might block solar radiation, but they do not provide a significant improvement to window system thermal transmittance. Cellular shades have better thermal performance compared to other shading devices because of the honeycomb structure that traps air in pockets to create thermal insulation. However, evaluating the energy savings potential of cellular shades using experimental testing in commercial settings is limited. Moreover, the effect of cellular shades on daylighting and glare is yet to be evaluated using field testing. In this study, experimental testing of cellular shades was performed in a real building with emulated occupancy for both a cooling and a heating season. Compared with a room without shades, the use of cellular shades in experimental testing showed incremental energy savings of 4.6% to 9.4% for cooling and higher than 20% for heating. The experimental data were used to calibrate the baseline energy model and validate the cellular shades model. Annual simulation of cellular shades was performed for a medium office prototype building using the validated cellular shades model. The annual simulation was performed in Phoenix, Nashville, and Rochester. The annual savings for HVAC energy was 25% for Phoenix, 27% for Nashville, and 19% for Rochester.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of the Financial Impacts of Building Performance Standard Penalties on Commercial Buildings in Aurora, Colorado

Buildings are responsible for 30% of total energy consumption worldwide. To address building energy, jurisdictions in the USA have enacted Building Performance Standards (BPS) legislation. The objective of BPS is to reduce energy consumption in buildings, thereby reducing the energy burden on utility infrastructure and other externalities. This is accomplished by setting mandatory energy use limits coupled with penalties for exceeding those limits. One of the key questions in BPS policymaking is how these penalties might impact the finances of building owners and tenants. This paper presents an analysis of BPS penalties in Aurora, Colorado, specifically targeting buildings impacted by the adopted statewide BPS legislation. Several BPS penalty structures were applied to the affected building stock in Aurora, and the potential impacts on building owner returns and tenant rents were estimated. The results show that for some combinations of building types and penalty structures, potential rent increases due to penalties could match or exceed typical yearly rent increases. The results also show that in most cases, for Aurora, there was no statistically significant difference in impact between buildings located in under-resourced and well-resourced areas.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗