Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “computed tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Qualitative and quantitative analysis of neutron irradiation effects in SiC/SiC composites using X-ray computed tomography

Silicon carbide fiber-reinforced silicon carbide matrix (SiC/SiC) composites are candidate materials for cladding of light water reactor (LWR) fuels. Loss of fission product gas retention due to the formation of microcrack networks is considered a potential failure mechanism for SiC/SiC-cladded fuels. In this work, a variety of SiC/SiC composite tubes were irradiated with and without an LWR-relevant radial heat flux in the High Flux Isotope Reactor, followed by detailed characterization with X-ray computed tomography (XCT). This first set of XCT data for neutron-irradiated samples confirmed that the internal stresses arising from a combination of temperature gradients and irradiation-induced swelling act as the primary driver for cracking. Consequently, while the observed cracking patterns varied depending on the tube architectures, the sharp edges of relatively large pores were found to be the common stress concentrator. These findings are useful to help improve the design and manufacturing of SiC/SiC fuel claddings for reduced failure probability.

42 ENGINEERING↗

Organ localization: Toward prospective patient-specific organ dosimetry in computed tomography

Purpose: With increased focus on radiation dose from medical imaging, prospective radiation dose estimates are becoming increasingly desired. Using available populations of adult and pediatric patient phantoms, radiation dose calculations can be catalogued and prospectively applied to individual patients that best match certain anatomical characteristics. In doing so, the knowledge of organ size and location is a required element. Here, the authors develop a predictive model of organ locations and volumes based on an analysis of adult and pediatric computed tomography (CT) data. Methods: Fifty eight adult and 69 pediatric CT datasets were segmented and utilized in the study. The maximum and minimum points of the organs were recorded with respect to the axial distance from the tip of the sacrum. The axial width, midpoint, and volume of each organ were calculated. Linear correlations between these three organ parameters and patient age, BMI, weight, and height were determined. Results: No statistically significant correlations were found in adult patients between the axial width, midpoint, and volume of the organs versus the patient age or BMI. Slight, positive linear trends were found for organ midpoint versus patient weight (max r{sup 2} = 0.382, mean r{sup 2} = 0.236). Similar trends were found for organ midpoint versus height (max r{sup 2} = 0.439, mean r{sup 2} = 0.200) and for organ volume versus height (max r{sup 2} = 0.410, mean r{sup 2} = 0.153). Gaussian fits performed on probability density functions of the adult organs resulted in r{sup 2}-values ranging from 0.96 to 0.996. The pediatric patients showed much stronger correlations overall. Strong correlations were observed between organ axial midpoint versus age, height, and weight (max r{sup 2} = 0.842, mean r{sup 2} = 0.790; max r{sup 2} = 0.949, mean r{sup 2} = 0.894; and max r{sup 2} = 0.870, mean r{sup 2} = 0.847, respectively). Moderate linear correlations were also observed for organ axial width versus height (max r{sup 2} = 0.772, mean r{sup 2} = 0.562) and for organ volume versus height (max r{sup 2} = 0.781, mean r{sup 2} = 0.601). Conclusions: Adult patients exhibited small variations in organ volume and location with respect to height and weight, but no meaningful correlation existed between these parameters and age or BMI. Once adulthood is reached, organ morphology and positioning seem to remain static. However, clear trends are evident between pediatric organ locations versus age, height, and weight. Such information can be incorporated into a matching methodology that may provide the highest probability of representing the anatomy of a patient undergoing a clinical exam to prospectively estimate the radiation dose.

60 APPLIED LIFE SCIENCES↗

Lung Texture in Serial Thoracic Computed Tomography Scans: Correlation of Radiomics-based Features With Radiation Therapy Dose and Radiation Pneumonitis Development

Purpose: To assess the relationship between radiation dose and change in a set of mathematical intensity- and texture-based features and to determine the ability of texture analysis to identify patients who develop radiation pneumonitis (RP). Methods and Materials: A total of 106 patients who received radiation therapy (RT) for esophageal cancer were retrospectively identified under institutional review board approval. For each patient, diagnostic computed tomography (CT) scans were acquired before (0-168 days) and after (5-120 days) RT, and a treatment planning CT scan with an associated dose map was obtained. 32- × 32-pixel regions of interest (ROIs) were randomly identified in the lungs of each pre-RT scan. ROIs were subsequently mapped to the post-RT scan and the planning scan dose map by using deformable image registration. The changes in 20 feature values (ΔFV) between pre- and post-RT scan ROIs were calculated. Regression modeling and analysis of variance were used to test the relationships between ΔFV, mean ROI dose, and development of grade ≥2 RP. Area under the receiver operating characteristic curve (AUC) was calculated to determine each feature's ability to distinguish between patients with and those without RP. A classifier was constructed to determine whether 2- or 3-feature combinations could improve RP distinction. Results: For all 20 features, a significant ΔFV was observed with increasing radiation dose. Twelve features changed significantly for patients with RP. Individual texture features could discriminate between patients with and those without RP with moderate performance (AUCs from 0.49 to 0.78). Using multiple features in a classifier, AUC increased significantly (0.59-0.84). Conclusions: A relationship between dose and change in a set of image-based features was observed. For 12 features, ΔFV was significantly related to RP development. This study demonstrated the ability of radiomics to provide a quantitative, individualized measurement of patient lung tissue reaction to RT and assess RP development.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Three-dimensional computed tomography from interferometric measurements within a narrow cone of views

A theory to determine the properties of a fluid from measurements of its projections was developed and tested. Viewing cones as small as 10 degrees were evaluated, with the only assumption being that the property was space limited. The results of applying the theory to numerical and actual interferograms of a spherical discontinuity of refractive index are presented. The theory was developed to test the practicality and limits of using three dimensional computer tomography in internal fluid dynamics.

Decker, Arthur J.↗

Three-dimensional computed tomography from interferometric measurements within a narrow cone of views

A theory to determine the properties of a fluid from measurements of its projections was developed and tested. Viewing cones as small as 10 degrees were evaluated, with the only assumption being that the property was space limited. The results of applying the theory to numerical and actual interferograms of a spherical discontinuity of refractive index are presented. The theory was developed to test the practicality and limits of using three-dimensional computer tomography in internal fluid dynamics.

Decker, Arthur J.↗

High-Resolution X-Ray and Neutron Computed Tomography of an Engine Combustion Network Spray G Gasoline Injector

Given the importance of the fuel-injection process on the combustion and emissions performance of gasoline direct injected engines, there has been significant recent interest in understanding the fluid dynamics within the injector, particularly around the needle and through the nozzles. Furthermore, the pressure losses and transients that occur in the flow passages above the needle are also of interest. Simulations of these injectors typically use the nominal design geometry, which does not always match the production geometry. Computed tomography (CT) using x-ray and neutron sources can be used to obtain the real geometry from production injectors, but there are trade-offs in using these techniques. X-ray CT provides high resolution, but cannot penetrate through the thicker parts of the injector. Neutron CT has excellent penetrating power but lower resolution. Here, we present results from a joint effort to characterize a gasoline direct injector representative of the Spray G injector as defined by the Engine Combustion Network. High-resolution (1.2 to 3 µm) x-ray CT measurements from the Advanced Photon Source at Argonne National Laboratory were combined with moderate-resolution (40 µm) neutron CT measurements from the High Flux Isotope Reactor at Oak Ridge National Laboratory to generate a complete internal geometry for the injector. This effort combined the strengths of both facilities’ capabilities, with extremely fine spatially resolved features in the nozzles and injector tips and fine resolution of internal features of the needle along the length of injector. Analysis of the resulting surface model of the internal fluid flow volumes of the injector reveals how the internal cross-sectional area and nozzle hole geometry differs slightly from the design dimensions. A simplified numerical simulation of the internal flow shows how deviations from the design geometry can alter the flow inside the sac and holes. Our results of this study will provide computational modelers with very accurate solid and surface models for use in computational fluid dynamics studies and experimentalists with increased insight into the operating characteristics of their injectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tools for pressure core sub-coring and pore-scale micro-CT (computed tomography) scans

Abstract. The pore habits of gas hydrate in natural sediment matrices provide essential clues for understanding physical (mechanical, thermal, hydraulic, and electrical) properties of hydrate-bearing sediments, yet there are no tools that can directly visualize the pore habits of natural gas hydrate other than indirect interpretation based on core-scale or field-scale observations. A significant challenge is to obtain a mini-core from pressure cores retrieved from natural reservoirs for high-resolution micro-CT (computed tomography) scans while maintaining pressure and temperature conditions required for stability of gas hydrate during all operational steps including manipulation, cutting, transferring, sub-coring and CT scanning. We present a new set of tools for pore-scale micro-CT imaging of natural hydrate-bearing sediments while maintaining pressure and temperature control. The tests with laboratory-prepared cores and pressure cores successfully demonstrate the capability of this set of tools to subsample a mini-core from pressure cores, transfer the mini-core to an X-ray transparent core holder, and conduct micro-CT scans. Successfully obtained CT images prove the functionality of this set of tools.

Seol, Yongkoo↗

Investigating Phase-Change-Induced Flow in Gas Diffusion Layers in Fuel Cells with X-ray Computed Tomography

The performance of polymer-electrolyte fuel cells is heavily dependent on proper management of liquid water. One particular reason is that liquid water can collect in the gas diffusion layers (GDLs) blocking the reactant flow to the catalyst layer. This results in increased mass-transport losses. At higher temperatures, evaporation of water becomes a dominant water-removal mechanism and specifically phase-change-induced (PCI) flow is present due to thermal gradients. This study used synchrotron based micro X-ray computed tomography (CT) to visualize and quantify the water distribution within gas diffusion layers subject to a thermal gradient. Plotting saturation as a function of through-plane distance quantitatively shows water redistribution, where water evaporates at hotter locations and condenses in colder locations. The morphology of the 2 GDLs on the micro-scale, as well as evaporating water clusters, are resolved, indicating that the GDL voids are slightly prolate, whereas water clusters are oblate. From the mean radii of water distributions and visual inspection, it is observed that larger water clusters evaporate faster than smaller ones.

25 ENERGY STORAGE↗

Computed Tomography 3-D Imaging of the Metal Deformation Flow Path in Friction Stir Welding

In friction stir welding (FSW), a rotating threaded pin tool is inserted into a weld seam and literally stirs the edges of the seam together. To determine optimal processing parameters for producing a defect free weld, a better understanding of the resulting metal deformation flow path is required. Marker studies are the principal method of studying the metal deformation flow path around the FSW pin tool. In our study, we have used computed tomography (CT) scans to reveal the flow pattern of a lead wire embedded in a FSW weld seam. At the welding temperature of aluminum, the lead becomes molten and is carried with the macro-flow of the weld metal. By using CT images, a 3-dimensional (3D) image of the lead flow pattern can be reconstructed. CT imaging was found to be a convenient and comprehensive way of collecting and displaying tracer data. It marks an advance over previous more tedious and ambiguous radiographic/metallographic data collection methods.

Schneider, Judy↗

Comparison of Repositioning Accuracy of Two Commercially Available Immobilization Systems for Treatment of Head-and-Neck Tumors Using Simulation Computed Tomography Imaging

Purpose: To compare the setup accuracy, comfort level, and setup time of two immobilization systems used in head-and-neck radiotherapy. Methods and Materials: Between February 2004 and January 2005, 21 patients undergoing radiotherapy for head-and-neck tumors were assigned to one of two immobilization devices: a standard thermoplastic head-and-shoulder mask fixed to a carbon fiber base (Type S) or a thermoplastic head mask fixed to the Accufix cantilever board equipped with the shoulder depression system. All patients underwent planning computed tomography (CT) followed by repeated control CT under simulation conditions during the course of therapy. The CT images were subsequently co-registered and setup accuracy was examined by recording displacement in the three cartesian planes at six anatomic landmarks and calculating the three-dimensional vector errors. In addition, the setup time and comfort of the two systems were compared. Results: A total of 64 CT data sets were analyzed. No difference was found in the cartesian total displacement errors or total vector displacement errors between the two populations at any landmark considered. A trend was noted toward a smaller mean systemic error for the upper landmarks favoring the Accufix system. No difference was noted in the setup time or comfort level between the two systems. Conclusion: No significant difference in the three-dimensional setup accuracy was identified between the two immobilization systems compared. The data from this study reassure us that our technique provides accurate patient immobilization, allowing us to limit our planning target volume to <4 mm when treating head-and-neck tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Influence of computed tomography contrast agent on radiotherapy dose calculation for pancreatic carcinoma: A dosimetric study based on tomotherapy and volumetric-modulated arc therapy techniques

The main purpose of our investigation was to quantify the dosimetric influence of intravenous contrast agent for pancreatic cancer radiotherapy treatment. This study focused on complex modulated irradiation techniques of tomotherapy (TOMO) and volumetric-modulated arc therapy (VMAT) to investigate if novel conformal treatment methods could reduce the influence of contrast agent. In our study, patients with pancreatic cancer were enrolled to have 2 computed tomography (CT) scans in the same position without and with intravenous contrast agent for treatment planning. Then tumors and organ at risks were countered on contrast-enhanced CT (CECT) images. Each patient's CECT was assigned a TOMO plan and a VMAT plan. Then these plans were copied onto the non-CECT image and dose distribution was calculated with the same algorithm and structure sets. Finally, the dose distribution and the dose difference were analyzed for the target volume and organs at risk between the 2 sets of images. The statistic dosimetric result showed that for both TOMO and VMAT, no significant dose difference between CECT and non-CECT-based plan was observed. Dose difference was clinically negligible because the average relative percentage dose difference was 1% ± 1% for target volume, except a blurring effect at the higher dose region of the target volume. It implied that intravenous contrast agent will not affect dose calculation for pancreatic cancer radiotherapy significantly. Also the dose deviation based on TOMO showed no statistical difference compared with that on VMAT. For both superposition/conversation algorithm used by TOMO and Monte Carlo algorithm used by VMAT, the dosimetric difference was nonsignificant. A full analysis demonstrated a negligible dose difference of less than 1% between CECT-based plan and non-CECT-based plan. Therefore, contrast-enhanced CT image can be used directly for dose calculation of TOMO and VMAT plans for pancreatic cancer. It is unnecessary to scan twice then make a fusion of CECT and non-CECT, which would result to additional unnecessary radiation dose to patient and decrease work efficiency.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Review methods for image segmentation from computed tomography images

Image segmentation is a challenging process in order to get the accuracy of segmentation, automation and robustness especially in medical images. There exist many segmentation methods that can be implemented to medical images but not all methods are suitable. For the medical purposes, the aims of image segmentation are to study the anatomical structure, identify the region of interest, measure tissue volume to measure growth of tumor and help in treatment planning prior to radiation therapy. In this paper, we present a review method for segmentation purposes using Computed Tomography (CT) images. CT images has their own characteristics that affect the ability to visualize anatomic structures and pathologic features such as blurring of the image and visual noise. The details about the methods, the goodness and the problem incurred in the methods will be defined and explained. It is necessary to know the suitable segmentation method in order to get accurate segmentation. This paper can be a guide to researcher to choose the suitable segmentation method especially in segmenting the images from CT scan.

60 APPLIED LIFE SCIENCES↗

Image processing workflow yielding high contrast synchrotron nanoscale computed tomography data from Ni-YSZ electrodes

The operating lifetime of Ni-YSZ fuel electrodes used in solid oxide electrolysis cells and fuel cells (SOECs and SOFCs) is limited by Ni redistribution, one of the primary degradation mechanisms that must be overcome to extend the longevity and maximize the performance of SOECs and SOFCs. To achieve this, 3D microstructural data is needed to relate both initial performance and performance loss over time to microstructural properties and their evolution throughout operation under various conditions. However, 3D microstructure data remains relatively scarce within the literature due to multiple challenges in acquiring and analyzing such data reliably. This work presents a workflow for acquiring and processing synchrotron X-ray nanoscale computed tomography (nano-CT) data from Ni-YSZ electrodes. Parameters for each step in the nano-CT workflow are described up to the final result (a 3D reconstruction), with particular emphasis on image alignment using freely available software. Following the results of a parametric sweep of the image alignment step, high contrast, low signal-to-noise 3D nano-CT data is obtained with relatively short compute times. While the exact methods best suited to samples with different microstructural qualities, or similar Ni-YSZ nano-CT data obtained from other sources may deviate from the solution found herein, this work also generalizes the decision points and evaluation of each step to provide a starting point to adapt this workflow to other datasets.

08 HYDROGEN↗

High Resolution Computed Tomography Inspection of Components Uncovers Root Causes of Vexing Failure Mysteries

During testing of actuators for fight programs, failures have occurred that required closure with an understanding of the root cause of the failure. For some InSight project actuators, intermittent changes of the winding resistance of the motors during temperature changes was extremely baffling. It was critical to determine the cause of the intermittent characteristic because the actuators were stock from a previous program and the company that provided the motors was no longer in business. Using an X-Ray Computed-Tomography (CT) method, the exact source of the intermittent failure was determined and completely understood – at dimensions of less than 20 microns. In another case, after the completion of an actuator’s life-test-to-failure, inspection was required to determine the source of the failure. The size of the actuator (10 mm diameter) required destructive means to get to the interior of the actuator for inspection, risking the loss of the source of the failure. Using CT imaging, the exact source of the failure was determined.

Johnson, Michael R.↗

A Detector for Proton Computed Tomography

Radiation therapy is a widely recognized treatment for cancer. Energetic protons have distinct features that set them apart from photons and make them desirable for cancer therapy as well as medical imaging. The clinical interest in heavy ion therapy is due to the fact that ions deposit almost all of their energy in a sharp peak – the Bragg peak- at the very end of their path. Proton beams can be used to precisely localize a tumor and deliver an exact dose to the tumor with small doses to the surrounding tissue. Proton computed tomography (pCT) provides direct information on the location on the target tumor, and avoids position uncertainty caused by treatment planning based on imaging with X-ray CT. The pCT project goal is to measure and reconstruct the proton relative stopping power distribution directly in situ. To ensure the full advantage of cancer treatment with 200 MeV proton beams, pCT must be realized.

Blazey, G.↗

Radiopaque Resists for Two-Photon Lithography To Enable Submicron 3D Imaging of Polymer Parts via X-ray Computed Tomography

Two-photon lithography (TPL) is a high-resolution additive manufacturing (AM) technique capable of producing arbitrarily complex three-dimensional (3D) microstructures with features 2–3 orders of magnitude finer than human hair. This process finds numerous applications as a direct route toward the fabrication of novel optical and mechanical metamaterials, miniaturized optics, microfluidics, biological scaffolds, and various other intricate 3D parts. As TPL matures, metrology and inspection become a crucial step in the manufacturing process to ensure that the geometric form of the end product meets design specifications. X-ray-based computed tomography (CT) is a nondestructive technique that can provide this inspection capability for the evaluation of complex internal 3D structure. However, polymeric photoresists commonly used for TPL, as well as other forms of stereolithography, poorly attenuate X-rays due to the low atomic number (Z) of their constituent elements and therefore appear relatively transparent during imaging. We present the development of optically clear yet radiopaque photoresists for enhanced contrast under X-ray CT. We have synthesized iodinated acrylate monomers to formulate high-Z photoresist materials that are capable of forming 3D microstructures with sub-150 nm features. In addition, we have developed a formulation protocol to match the refractive index of the photoresists to the immersion medium of the objective lens so as to enable dip-in laser lithography, a direct laser writing technique for producing millimeter-tall structures. Our radiopaque photopolymer then resists increase X-ray attenuation by a factor of more than 10 times without sacrificing the sub-150 nm feature resolution or the millimeter-scale part height. Thus, our resists can successfully replace existing photopolymers to generate AM parts that are suitable for inspection via X-ray CT. By providing the “feedstock” for radiopaque AM parts, our resist formulation is expected to play a critical role in enabling fabrication of functional polymer parts to tight design tolerances.

36 MATERIALS SCIENCE↗

Effect of particle size on pore three-dimensional characteristics of SiCp preforms by X-ray micro-computed tomography

Highlights: • X-ray μ-CT was used to characterize 3D structures of the pores in SiCp preforms. • 3D pore network models of the pore structure were extracted and analyzed. • With the increase of particle size, the homogeneity of pore distribution decreased. • Small particles in large spaces of coarse particles decreased preform connectivity. - Abstract: Silicon-carbide particle (SiC{sub p}) preforms with particle sizes of 20, 50, 100 and 150 μm were prepared by compression mold forming and heat treatment. A high resolution (~ 1.0 μm) three-dimensional (3D) X-ray micro-computed tomography (X-ray μ-CT) combined with 3D pore-network models were used to study the effect of particle size on 3D characteristics and spatial structures of pores in the preforms. The results demonstrated that as the particle size increased, the gap expansion caused by burning of starch reduced. When the particle size increased from 20 to 100 μm, the average areal porosity, homogeneity of pore distribution, connectivity, the numbers of small pores and throats, and average pore coordination number decreased; the average effective sizes of pores and throats increased. When the particle size further increased to 150 μm, the large gaps were filled by small particles resulted from the broken coarse particles, which decreased the homogeneity and connectivity of pores. As a result, the pore-network analysis shows that the numbers of small pores and throats and average pore coordination number increased.

36 MATERIALS SCIENCE↗

Imaging the Aqueous Humor Outflow Pathway in Human Eyes by Three-dimensional Micro-computed Tomography (3D micro-CT)

The site of outflow resistance leading to elevated intraocular pressure in primary open-angle glaucoma is believed to be located in the region of Schlemm's canal inner wall endothelium, its basement membrane and the adjacent juxtacanalicular tissue. Evidence also suggests collector channels and intrascleral vessels may have a role in intraocular pressure in both normal and glaucoma eyes. Traditional imaging modalities limit the ability to view both proximal and distal portions of the trabecular outflow pathway as a single unit. In this study, we examined the effectiveness of three-dimensional micro-computed tomography (3D micro-CT) as a potential method to view the trabecular outflow pathway. Two normal human eyes were used: one immersion fixed in 4% paraformaldehyde and one with anterior chamber perfusion at 10 mmHg followed by perfusion fixation in 4% paraformaldehyde/2% glutaraldehyde. Both eyes were postfixed in 1% osmium tetroxide and scanned with 3D micro-CT at 2 {mu}m or 5 {mu}m voxel resolution. In the immersion fixed eye, 24 collector channels were identified with an average orifice size of 27.5 {+-} 5 {mu}m. In comparison, the perfusion fixed eye had 29 collector channels with a mean orifice size of 40.5 {+-} 13 {mu}m. Collector channels were not evenly dispersed around the circumference of the eye. There was no significant difference in the length of Schlemm's canal in the immersed versus the perfused eye (33.2 versus 35.1 mm). Structures, locations and size measurements identified by 3D micro-CT were confirmed by correlative light microscopy. These findings confirm 3D micro-CT can be used effectively for the non-invasive examination of the trabecular meshwork, Schlemm's canal, collector channels and intrascleral vasculature that comprise the distal outflow pathway. This imaging modality will be useful for non-invasive study of the role of the trabecular outflow pathway as a whole unit.

59 BASIC BIOLOGICAL SCIENCES↗