Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “coherent radiation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Thermal Neutron Scattering Improvements and Fixes for MCNP6.3 [Slides]

Major error (10,000+ pcm) discovered when using uranium-dioxide or uranium-nitride included in ENDF80SaB2 release. Improvements are being made towards preparing the code for ENDF/B-VIII.1 (ACE) format updates. A minor error (0-10’s pcm) was discovered while working on new capability development for Lab Directed Research & Development (LDRD) project. Previously, only a single coherent or incoherent elastic channel (along with an inelastic channel) was allowed in a thermal neutron scattering evaluation and subsequent processed ACE file. Based on what is planned in ENDF/B-VIII.1 release, there will be (a) new thermal scattering evaluation(s) which uses this mixed-mode coherent and incoherent elastic scattering blocks. MCNP6.3 has been modified to be able to handle such data in the future. Some reorganization has been made in the cross section calculation (acetot, sabcol, colidn) in the presence of TSL data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Numerically Exact Computer Simulations of Light Scattering by Densely Packed, Random Particulate Media

Direct computer simulations of electromagnetic scattering by discrete random media have become an active area of research. In this progress review, we summarize and analyze our main results obtained by means of numerically exact computer solutions of the macroscopic Maxwell equations. We consider finite scattering volumes with size parameters in the range, composed of varying numbers of randomly distributed particles with different refractive indices. The main objective of our analysis is to examine whether all backscattering effects predicted by the low-density theory of coherent backscattering (CB) also take place in the case of densely packed media. Based on our extensive numerical data we arrive at the following conclusions: (i) all backscattering effects predicted by the asymptotic theory of CB can also take place in the case of densely packed media; (ii) in the case of very large particle packing density, scattering characteristics of discrete random media can exhibit behavior not predicted by the low-density theories of CB and radiative transfer; (iii) increasing the absorptivity of the constituent particles can either enhance or suppress typical manifestations of CB depending on the particle packing density and the real part of the refractive index. Our numerical data strongly suggest that spectacular backscattering effects identified in laboratory experiments and observed for a class of high-albedo Solar System objects are caused by CB.

Dlugach, Janna M.↗

Combining Laue diffraction with Bragg coherent diffraction imaging at 34-ID-C

Measurement modalities in Bragg coherent diffraction imaging (BCDI) rely on finding a signal from a single nanoscale crystal object which satisfies the Bragg condition among a large number of arbitrarily oriented nanocrystals. However, even when the signal from a single Bragg reflection with ( hkl ) Miller indices is found, the crystallographic axes on the retrieved three-dimensional (3D) image of the crystal remain unknown, and thus localizing in reciprocal space other Bragg reflections becomes time-consuming or requires good knowledge of the orientation of the crystal. Here, the commissioning of a movable double-bounce Si (111) monochromator at the 34-ID-C endstation of the Advanced Photon Source is reported, which aims at delivering multi-reflection BCDI as a standard tool in a single beamline instrument. The new instrument enables, through rapid switching from monochromatic to broadband (pink) beam, the use of Laue diffraction to determine crystal orientation. With a proper orientation matrix determined for the lattice, one can measure coherent diffraction patterns near multiple Bragg peaks, thus providing sufficient information to image the full strain tensor in 3D. The design, concept of operation, the developed procedures for indexing Laue patterns, and automated measuring of Bragg coherent diffraction data from multiple reflections of the same nanocrystal are discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Multi-frame, ultrafast, x-ray microscope for imaging shockwave dynamics

Inertial confinement fusion (ICF) holds increasing promise as a potential source of abundant, clean energy, but has been impeded by defects such as micro-voids in the ablator layer of the fuel capsules. It is critical to understand how these micro-voids interact with the laser-driven shock waves that compress the fuel pellet. At the Matter in Extreme Conditions (MEC) instrument at the Linac Coherent Light Source (LCLS), we utilized an x-ray pulse train with ns separation, an x-ray microscope, and an ultrafast x-ray imaging (UXI) detector to image shock wave interactions with micro-voids. To minimize the high- and low-frequency variations of the captured images, we incorporated principal component analysis (PCA) and image alignment for flat-field correction. After applying these techniques we generated phase and attenuation maps from a 2D hydrodynamic radiation code (xRAGE), which were used to simulate XPCI images that we qualitatively compare with experimental images, providing a one-to-one comparison for benchmarking material performance. Moreover, we implement a transport-of-intensity (TIE) based method to obtain the average projected mass density (areal density) of our experimental images, yielding insight into how defect-bearing ablator materials alter microstructural feature evolution, material compression, and shock wave propagation on ICF-relevant time scales.

47 OTHER INSTRUMENTATION↗

Making and breaking terahertz waves with fluid plasmas

Vigorous research efforts during the past several decades have successfully closed the “terahertz gap” between microwaves and infrared light, offering new and increasingly efficient ways to produce, detect, and manipulate radiation fields in the terahertz (THz) frequency range. In our laboratory, THz time-domain spectroscopy (THz-TDS) and optical-pump THz-probe (OPTP) experiments have been routinely utilized as ultrafast spectroscopy tools to investigate a variety of emerging quantum materials and metamaterials. The ultrafast THz pulses are produced by femtosecond laser excitation of photoconductive antennas, semiconductor surfaces (InAs), and nonlinear crystals (ZnTe, GaSe, and LiNbO 3 ). Photoconductive antennas and nonlinear crystals also allow for the coherent detection of these pulses in the time domain, with amplitude and phase spectra obtained in the frequency domain via fast Fourier transform. Although such solid-state schemes are highly desirable in many aspects and thus also commonly utilized in many research laboratories and industrial applications, they typically suffer from limited bandwidths due to the absorption and frequency dispersion induced primarily by phonon resonances, limiting THz applications such as spectroscopy of emerging materials, imaging and detection, and biomedical characterization.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Stellar radio emission

This paper presents an overview of the various radiation mechanisms believed to play a role in stellar radio emission. The radio emission from most stars is nonthermal and is generally due to mildly relativistic electrons with energies from a few keV to over 10 MeV. Magnetic fields play a crucial role both in accelerating the electrons to the requisite energies and in mediating the emission mechanism. They also play a fundamental role in creating the velocity anisotropies that are necessary for the operation of some of the coherent emission mechanisms. Coherent emission is seen most commonly on the M dwarfs, rarely on the RS CVns, and has yet to be detected for any other class of star. These coherent processes are best studied by means of their dynamic spectra; such studies are now just getting underway.

Bookbinder, Jay A.↗

The Sobolev approximation for line formation with partial frequency redistribution

Attention is given to the formation of a spectral line in a uniformly expanding infinite medium in the Sobolev approximation, with emphasis on the various mechanisms for frequency redistribution. Numerical and analytic solutions of the transfer equation are presented of a number of redistribution functions and their approximations, including type I and type II partial redistribution, coherent scattering and complete redistribution, and the Fokker-Planck and uncorrelated approximation to the R sub II function. The solutions for the mean intensity are shown to depend very much on the type of redistribution mechanism, while for the frequency-weighted mean intensity, which enters the rate equations, this dependence is weak. It is inferred that use of Sobolev escape probabilities based on complete redistribution can be an adequate approximation for many calculations for which only the radiative excitation rates are needed.

Hummer, D. G.↗

Search for Gravitational Waves From Scorpius X-1 in the Second Advanced LIGO Observing Run With an Improved Hidden Markov Model

We present results from a semi coherent search for continuous gravitational waves from the low-mass x-ray binary Scorpius X-1, using a hidden Markov model (HMM) to track spin wandering. This search improves on previous HMM-based searches of LIGO data by using an improved frequency domain matched filter, the J-statistic, and by analyzing data from Advanced LIGO’s second observing run. In the frequency range searched, from 60 to 650 Hz, we find no evidence of gravitational radiation. At 194.6 Hz, the most sensitive search frequency, we report an upper limit on gravitational wave strain (at 95% confidence) ofh95%0¼3.47×10−25when marginalizing over source inclination angle. This is the most sensitive search for Scorpius X-1, to date, that is specifically designed to be robust in the presence of spin wandering.

B P Abbott↗

Quantum dynamics of a nucleon in the Fermi accelerator

Highlights: • In nuclear physics, the Fermi accelerator is a coherent open quantum system. • There is not a true equilibrium for a nucleon‘s mean-energy in the Fermi accelerator. • Occupation of higher energy eigen-states remains even after the mean-energy plateaus. • This work paves the way for work on quantum tunnelling in the Fermi accelerator. The quantum dynamics of a particle in a one-dimensional box with an oscillating wall (the Fermi accelerator) is investigated. The model is applied to the motion of a single nucleon in the mean-field potential of a heavy atomic nucleus whose surface vibrates. By directly solving the time-dependent Schrödinger equation, both the state of the particle and its mean-energy are studied. The effects of the frequency of the wall oscillation on the nucleon’s energy are addressed. Its energy oscillates in phase with the moving wall for all frequencies, showing no chaotic behaviour. There is a large initial peak of the nucleon’s energy as the particle adjusts to the sudden change in the size of the box and a varying relaxation time as it plateaus towards lower energy and a partial equilibrium. Small oscillations in energy continue, since there cannot be a true equilibrium while the wall is moving. The quantum coherence between the different parts of the nucleon’s wave-function in real space is very much preserved. This research lays the foundation for future investigations into quantum tunnelling in the Fermi accelerator.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Searching for Cost-Optimized Interstellar Beacons

What would SETI beacon transmitters be like if built by civilizations that had a variety of motives but cared about cost? In a companion paper, we presented how, for fixed power density in the far field, a cost-optimum interstellar beacon system could be built. Here, we consider how we should search for a beacon if it were produced by a civilization similar to ours. High-power transmitters could be built for a wide variety of motives other than the need for two-way communication, this would include beacons built to be seen over thousands of light-years. Extraterrestrial beacon builders would likely have to contend with economic pressures just as their terrestrial counterparts do. Cost, spectral lines near 1GHz, and interstellar scintillation favor radiating frequencies substantially above the classic "water hole." Therefore, the transmission strategy for a distant, cost-conscious beacon would be a rapid scan of the galactic plane with the intent to cover the angular space. Such pulses would be infrequent events for the receiver. Such beacons built by distant, advanced, wealthy societies would have very different characteristics from what SETI researchers seek. Future searches should pay special attention to areas along the galactic disk where SETI searches have seen coherent signals that have not recurred on the limited listening time intervals we have used. We will need to wait for recurring events that may arrive in intermittent bursts. Several new SETI search strategies have emerged from these ideas. We propose a new test for beacons that is based on the Life Plane hypotheses.

Benford, Gregory↗

Earth-system-model evaluation of cloud and precipitation occurrence for supercooled and warm clouds over the Southern Ocean's Macquarie Island

Abstract. Over the remote Southern Ocean (SO), cloud feedbacks contribute substantially to Earth system model (ESM) radiative biases. The evolution of low Southern Ocean clouds (cloud-top heights < ∼ 3 km) is strongly modulated by precipitation and/or evaporation, which act as the primary sink of cloud condensate. Constraining precipitation processes in ESMs requires robust observations suitable for process-level evaluations. A year-long subset (April 2016–March 2017) of ground-based profiling instrumentation deployed during the Macquarie Island Cloud and Radiation Experiment (MICRE) field campaign (54.5∘ S, 158.9∘ E) combines a 95 GHz (W-band) Doppler cloud radar, two lidar ceilometers, and balloon-borne soundings to quantify the occurrence frequency of precipitation from the liquid-phase cloud base. Liquid-based clouds at Macquarie Island precipitate ∼ 70 % of the time, with deeper and colder clouds precipitating more frequently and at a higher intensity compared to thinner and warmer clouds. Supercooled cloud layers precipitate more readily than layers with cloud-top temperatures > 0 ∘C, regardless of the geometric thickness of the layer, and also evaporate more frequently. We further demonstrate an approach to employ these observational constraints for evaluation of a 9-year GISS-ModelE3 ESM simulation. Model output is processed through the Earth Model Column Collaboratory (EMC2) radar and lidar instrument simulator with the same instrument specifications as those deployed during MICRE, therefore accounting for instrument sensitivities and ensuring a coherent comparison. Relative to MICRE observations, the ESM produces a smaller cloud occurrence frequency, smaller precipitation occurrence frequency, and greater sub-cloud evaporation. The lower precipitation occurrence frequency by the ESM relative to MICRE contrasts with numerous studies that suggest a ubiquitous bias by ESMs to precipitate too frequently over the SO when compared with satellite-based observations, likely owing to sensitivity limitations of spaceborne instrumentation and different sampling methodologies for ground- versus space-based observations. Despite these deficiencies, the ESM reproduces the observed tendency for deeper and colder clouds to precipitate more frequently and at a higher intensity. The ESM also reproduces specific cloud regimes, including near-surface clouds that account for ∼ 25 % of liquid-based clouds during MICRE and optically thin, non-precipitating clouds that account for ∼ 27 % of clouds with bases higher than 250 m. We suggest that the demonstrated framework, which merges observations with appropriately constrained model output, is a valuable approach to evaluate processes responsible for cloud radiative feedbacks in ESMs.

54 ENVIRONMENTAL SCIENCES↗

Earth-System-Model Evaluation of Cloud and Precipitation Occurrence for Supercooled and Warm Clouds Over the Southern Ocean's Macquarie Island

Over the remote Southern Ocean (SO), cloud feedbacks contribute substantially to Earth system model (ESM) radiative biases. The evolution of low Southern Ocean clouds (cloud-top heights < ∼ 3 km) is strongly modulated by precipitation and/or evaporation, which act as the primary sink of cloud condensate. Constraining precipitation processes in ESMs requires robust observations suitable for process-level evaluations. A year-long subset (April 2016–March 2017) of ground-based profiling instrumentation deployed during the Macquarie Island Cloud and Radiation Experiment (MICRE) field campaign (54.5∘ S, 158.9∘ E) combines a 95 GHz (W-band) Doppler cloud radar, two lidar ceilometers, and balloon-borne soundings to quantify the occurrence frequency of precipitation from the liquid-phase cloud base. Liquid-based clouds at Macquarie Island precipitate ∼ 70 % of the time, with deeper and colder clouds precipitating more frequently and at a higher intensity compared to thinner and warmer clouds. Supercooled cloud layers precipitate more readily than layers with cloud-top temperatures > 0 ∘C, regardless of the geometric thickness of the layer, and also evaporate more frequently. We further demonstrate an approach to employ these observational constraints for evaluation of a 9-year GISS-ModelE3 ESM simulation. Model output is processed through the Earth Model Column Collaboratory (EMC2) radar and lidar instrument simulator with the same instrument specifications as those deployed during MICRE, therefore accounting for instrument sensitivities and ensuring a coherent comparison. Relative to MICRE observations, the ESM produces a smaller cloud occurrence frequency, smaller precipitation occurrence frequency, and greater sub-cloud evaporation. The lower precipitation occurrence frequency by the ESM relative to MICRE contrasts with numerous studies that suggest a ubiquitous bias by ESMs to precipitate too frequently over the SO when compared with satellite-based observations, likely owing to sensitivity limitations of spaceborne instrumentation and different sampling methodologies for ground- versus space-based observations. Despite these deficiencies, the ESM reproduces the observed tendency for deeper and colder clouds to precipitate more frequently and at a higher intensity. The ESM also reproduces specific cloud regimes, including near-surface clouds that account for ∼ 25 % of liquid-based clouds during MICRE and optically thin, non-precipitating clouds that account for ∼ 27 % of clouds with bases higher than 250 m. We suggest that the demonstrated framework, which merges observations with appropriately constrained model output, is a valuable approach to evaluate processes responsible for cloud radiative feedbacks in ESMs.

cloud feedbacks↗

Fast wave interferometer for ion density measurement on DIII-D

=A fast wave interferometer (FWI), which can measure ion mass density, has been developed on DIII-D for its use on future fusion reactors, as well as for the study of ion behavior in current plasma devices. The frequency of the fast waves used for the FWI is around 60 MHz, and require antennas and coaxial cables or waveguides, which, unlike traditional mirror-based optical interferometers, are less susceptible to neutron/gamma-ray radiation and are relatively immune to impurity deposition and erosion as well as alignment issues. The bulk ion density evaluated using FWI show good agreement with that derived from CO 2 interferometry within about 15%. When the ion mass density measurement by FWI is combined with an electron density measurement from CO 2 interferometry, Z eff measurements are also enabled and are in agreement with those from visible Bremsstrahlung measurements. Additionally, large-bandwidth FWI measurements clearly resolve 10–100 kHz coherent modes and demonstrate its potential as a core fluctuation diagnostic, sensitive to both magnetic and ion density perturbations.

Instruments & Instrumentation↗

Edge radiated temperature fluctuations across confinement regime transitions in favorable and unfavorable drift configurations at ASDEX Upgrade

Abstract The physics behind the difference in heating power threshold for the low to high confinement (L–H) transition between favorable ion B × ∇ B drift (toward active X -point) and unfavorable ion B × ∇ B drift (away from active X -point) magnetic configurations is a longstanding open question. In this work we show differences in edge ( ρ p o l = 0.95 –1.0) turbulence in matched heating power favorable and unfavorable magnetic configuration discharges using a correlation electron cyclotron emission diagnostic to measure radiated temperature ( T r a d ) fluctuations. During power matched L-mode phases, the edge T r a d fluctuations have higher amplitude in the unfavorable configuration plasma as compared to the favorable configuration plasma. The lower fluctuation amplitude in favorable configuration is observed concomitant with increased E × B shear, as compared to the unfavorable case. Although this turbulence is different in amplitude, it is similar in radial and frequency structure between favorable and unfavorable configurations and grows to the weakly coherent mode during the I-mode phase of the unfavorable configuration discharge. A broadband pedestal fluctuation is seen during an inter-ELM H-mode period of the favorable configuration discharge.

Physics↗

A Compton transmission polarimeter for DC and SRF electron photo-injectors

The production of high-current and intense spin polarized electron beams is of great importance in electron-based facilities. Tests are planned to produce such beams in 2023 using GaAs-based photocathodes installed in the Brookhaven National Lab RHIC Coherent electron Cooling superconducting radiofrequency (SRF) photogun [1]. A fast and efficient electron polarimeter operating in the MeV energy range is required to measure the beam spin polarization. While Mott polarimeters provide larger measured asymmetries, a Compton Transmission polarimeter is well suited in the few MeV energy range. In this work, we report on a relatively compact and cost-effective Compton transmission polarimeter which has been built and calibrated at Jefferson Lab (JLab). First, we present the design of the polarimeter radiator, polarized target analyzing magnet, BGO detector assembly and data acquisition system. Next, results of a two-week commissioning study performed at the JLab Upgraded Injector Test Facility will be described. Here, a well-known polarized electron beam produced from a bulk GaAs photocathode in a dc high-voltage photogun was first measured in a 180 keV Mott scattering polarimeter, then used to characterize and calibrate the Compton transmission polarimeter as a function of the polarized target magnetization and beam properties. Finally, we report an effective analyzing power of the Compton polarimeter and compare experimental results with those produced via Geant4 simulations.

Blume, G.↗

A Compton transmission polarimeter for DC and SRF electron photo-injectors

The production of high-current and intense spin polarized electron beams is of great importance in electron-based facilities. Tests are planned to produce such beams in 2023 using GaAs-based photocathodes installed in the Brookhaven National Lab RHIC Coherent electron Cooling superconducting radiofrequency (SRF) photogun [1]. A fast and efficient electron polarimeter operating in the MeV energy range is required to measure the beam spin polarization. While Mott polarimeters provide larger measured asymmetries, a Compton Transmission polarimeter is well suited in the few MeV energy range. In this work, we report on a relatively compact and cost-effective Compton transmission polarimeter which has been built and calibrated at Jefferson Lab (JLab). First, we present the design of the polarimeter radiator, polarized target analyzing magnet, BGO detector assembly and data acquisition system. Next, results of a two-week commissioning study performed at the JLab Upgraded Injector Test Facility will be described. Here, a well-known polarized electron beam produced from a bulk GaAs photocathode in a dc high-voltage photogun was first measured in a 180 keV Mott scattering polarimeter, then used to characterize and calibrate the Compton transmission polarimeter as a function of the polarized target magnetization and beam properties. Finally, we report an effective analyzing power of the Compton polarimeter and compare experimental results with those produced via Geant4 simulations.

Blume, G.↗

The angular dependence of partially redistributed resonance radiation

Explicit expressions for the angular distribution and frequency dependence of radiation scattered by a spatially degenerate atom undergoing collisions are derived using a previously developed formalism of the quantum theory of line broadening for an atom in its rest frame. Results valid in the impact regime for resonant scattering are presented for the cases of linear incident and scattered polarization circular incident and linear scattered polarization, and unpolarized incident radiation with no monitoring of the scattered polarization. These results relate to scattering involving a j - j + or - 1 - j atomic transition, with lower-state interactions neglected; the expressions obtained take a relatively simple form involving atomic multipolar relaxation rates of the order of k = 0 and k = 2. The angular distributions for each case are combined with the frequency dependences to yield a three-component frequency redistribution function for an s-p-s transition, the components being a coherent term, a frequency-redistributed term with the same angular dependence as the coherent term, and an isotropic frequency-redistributed term.

Ballagh, R. J.↗