Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “channel calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

The Global Precipitation Measurement (GPM) Mission: Overview and U.S. Science Status

The Global Precipitation Measurement (GPM) Mission, an international satellite mission to unify and advance space-based precipitation measurements around the globe, is a science mission with integrated application goals. The mission is designed to (1) advance the knowledge of the global water cycle and freshwater availability, and (2) improve weather, climate, and hydrological prediction capabilities through more accurate and frequent measurements of global precipitation. The cornerstone of GPM is the deployment of a Core Spacecraft in a unique 65 deg-inclined orbit to serve as a physics observatory and a calibration reference to improve the accuracy of precipitation measurements by a heterogeneous constellation of dedicated and operational passive microwave sensors. The Core Spacecraft will carry a dual-frequency (Ku-Ka band) radar and a multi-channel microwave radiometer with high-frequency capabilities to provide measurements of 3-D precipitation structures and microphysical properties, which are key to achieving a better understanding of precipitation processes and improved retrieval algorithms for passive microwave radiometers. The GPM constellation is envisioned to comprise 5 or more conical-scanning microwave radiometers provided by partners, augmented by cross-track microwave sounders on operational satellites such as the National Polar-orbiting Operational Environmental Satellite System (NPOESS) Preparatory Project (NPP), POES, NPOESS, and MetOp satellites for improved sampling over land. The GPM Mission is currently a partnership between NASA and the Japan Aerospace Exploration Agency (JAXA), with opportunities for additional international partners in constellation satellites and ground validation. An overview of the GPM mission concept and science activities in the United States will be presented.

Hou, Arthur↗

Simple, compact, high-resolution monochromatic x-ray source for characterization of x-ray calorimeter arrays

X-ray calorimeters routinely achieve very high spectral resolution, typically a few eV full width at half maximum (FWHM). Measurements of calorimeter line shapes are usually dominated by the natural linewidth of most laboratory calibration sources. This compounds the data acquisition time necessary to statistically sample the instrumental line broadening and can add systematic uncertainty if the intrinsic line shape of the source is not well known. To address these issues, we have built a simple, compact monochromatic x-ray source using channel cut crystals. A commercial x-ray tube illuminates a pair of channel cut crystals that are aligned in a dispersive configuration to select the Kα1 line of the x-ray tube anode material. The entire device, including the x-ray tube, can be easily hand-carried by one person and may be positioned manually or using a mechanical translation stage. The output monochromatic beam provides a collimated image of the anode spot with magnification of unity in the dispersion direction (typically 100 μm–200 μm for the x-ray tubes used here) and is unfocused in the cross-dispersion direction so that the source image in the detector plane appears as a line. We measured output count rates as high as 10 count/s/pixel for the Hitomi soft x-ray spectrometer, which had 819 μm square pixels. We implemented different monochromator designs for energies of 5.4 keV (one design) and 8.0 keV (two designs), which have effective theoretical FWHM energy resolution of 0.125 eV, 0.197 eV, and 0.086 eV, respectively; these are well-suited for optimal calibration measurements of state-of-the art x-ray calorimeters. We measured an upper limit for the energy resolution of our Cr Kα1 monochromator of 0.7 eV FWHM at 5.4 keV, consistent with the theoretical prediction of 0.125 eV.

47 OTHER INSTRUMENTATION↗

Simple, Compact, High-Resolution Monochromatic X-Ray Source for Characterization of X-Ray Calorimeter Arrays

X-ray calorimeters routinely achieve very high spectral resolution, typically a few eV full width at half maximum (FWHM). Measurements of calorimeter line shapes are usually dominated by the natural linewidth of most laboratory calibration sources. This compounds the data acquisition time necessary to statistically sample the instrumental line broadening and can add systematic uncertainty if the intrinsic line shape of the source is not well known. To address these issues, we have built a simple, compact monochromatic x-ray source using channel cut crystals. A commercial x-ray tube illuminates a pair of channel cut crystals that are aligned in a dispersive configuration to select the Kα1 line of the x-ray tube anode material. The entire device, including the x-ray tube, can be easily hand-carried by one person and may be positioned manually or using a mechanical translation stage. The output monochromatic beam provides a collimated image of the anode spot with magnification of unity in the dispersion direction (typically 100 μm–200 μm for the x-ray tubes used here) and is unfocused in the cross-dispersion direction so that the source image in the detector plane appears as a line. We measured output count rates as high as 10 count/s/pixel for the Hitomi soft x-ray spectrometer, which had 819 μm square pixels. We implemented different monochromator designs for energies of 5.4 keV (one design) and 8.0 keV (two designs), which have effective theoretical FWHM energy resolution of 0.125 eV, 0.197 eV, and 0.086 eV, respectively; these are well-suited for optimal calibration measurements of state-of-the art x-ray calorimeters. We measured an upper limit for the energy resolution of our Cr Kα1 monochromator of 0.7 eV FWHM at 5.4 keV, consistent with the theoretical prediction of 0.125 eV.

M A Leutenegger↗

Measurement of the Higgs boson mass with H → γγ decays in 140 fb –1 of $\sqrt{s}$ = 13 TeV pp collisions with the ATLAS detector

The mass of the Higgs boson is measured in the H→γγ decay channel, exploiting the high resolution of the invariant mass of photon pairs reconstructed from the decays of Higgs bosons produced in proton–proton collisions at a centre-of-mass energy $\sqrt{s}$ = 13 TeV. The dataset was collected between 2015 and 2018 by the ATLAS detector at the Large Hadron Collider, and corresponds to an integrated luminosity of 140 fb –1 . The measured value of the Higgs boson mass is 125.17 ± 0.11(stat.) ± 0.09(syst.) GeV and is based on an improved energy scale calibration for photons, whose impact on the measurement is about four times smaller than in the previous publication. A combination with the corresponding measurement using 7 and 8 TeV pp collision ATLAS data results in a Higgs boson mass measurement of 125.22 ± 0.11(stat.) ± 0.09(syst.) GeV. With an uncertainty of 1.1 per mille, this is currently the most precise measurement of the mass of the Higgs boson from a single decay channel.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

25-Pin metallic fuel performance benchmark case based on the EBR-II X430 experiments series

A metallic fuel benchmark case was developed for the fuel performance code BISON based on 25 uranium-zirconium and uranium-plutonium-zirconium pins of the Experimental Breeder Reactor II X430 experiment series. Results of the benchmarks were compared with measurements and calculations made at the time of the experiment as well as subsequent measurements reported in 2019. The comparisons were used to quantify the accuracy of the BISON predictions and to identify patterns in the BISON differences.BISON predicted burnup, plenum pressure, and fission gas release fractions accurately. BISON temperature predictions were somewhat cooler than the temperatures determined at the time of the experiment but appeared to be reasonably accurate considering uncertainties in the legacy temperature calculations, uncertainties in the legacy linear heat rate calculations, and the high sensitivities of the BISON-predicted temperatures to BISON inputs. Fuel axial elongation predictions had errors correlated to fuel composition; BISON tended to underpredict the elongation of binary fuels and overpredict the elongation of ternary fuels. BISON cladding radial dilation predictions were also significantly lower than legacy PIE measurements.Recommendations were made to improve the BISON fuel gaseous swelling model to account for fuel composition, to add additional capabilities to the coolant channel temperature model to ease benchmark development, and to continue developing benchmark cases based on a wide range of experiments in several reactors. Once a wide array of benchmarks is developed, an attempt can be made to enhance or calibrate BISON models to improve the cladding dilation predictions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Capability of Impedance Measurement Using Spread Spectrum Time-Domain Reflectometry

Spread spectrum time-domain reflectometry (SSTDR) has been proposed for measuring electrical impedance on live, energized systems, in electrically noisy environments, or for measuring multiple channels simultaneously. Here we evaluate the capability of SSTDR for impedance measurement from near dc to 96 MHz and find that they agree very well with measurements from a vector network analyzer (VNA). Time gating is used to remove (calibrate out) transmission line effects. We evaluate the frequency ranges over which SSTDR at different modulation frequencies is accurate for the measurement of series resistive–capacitive ( RC ) loads and observe that fusing measurements from multiple modulation frequencies can broaden the effective measurement bandwidth.

14 SOLAR ENERGY↗

SAM Code Enhancements for Modeling of Liquid Metal-Cooled Fast Reactor Concepts

The SAM code is under development and supported by DOE-NE’s Nuclear Energy Advanced Modeling and Simulation program as a modern system-level modeling and simulation tool for advanced non-light water reactor safety analyses. These advanced reactor concepts incorporate novel and improved approaches to achieve safety and economic feasibility. This report summarizes two major efforts in addressing the modeling gaps in SAM for liquid-metal-cooled fast reactor (LMFR) applications, i.e. thermal mixing and stratification phenomena in large pools and corrosion-oxidation of components in flowing lead. A new one-dimensional model for thermal mixing and stratification effects in large pools and enclosures is developed and implemented. Thermal mixing and stratification occur when fluid enters a pool at a temperature different than the bulk fluid itself, a scenario often encountered during transients in pool-type systems. These phenomena are critical for the safety of reactors, impacting phenomena like natural circulation, which is essential for passive cooling. The improved model in SAM addresses limitations of state-of-the-art approaches by combining one-dimensional (1D) channels, representing the coolant jet flow, with lumped-parameter zero-dimensional (0D) pools, representing the rest of coolant in the tank. Energy exchange between the 1D jet and the 0D pools is based on heat transfer correlations calibrated against 3D simulations. It is verified that this model can handle various flow configurations, including hot jets in colder pools, cold jets in hotter pools, and the presence of features like ceilings, free surfaces, and obstacles. Additionally, validation against experimental data demonstrates the ability of the model to capture mixing and stratification effects in a wide range of conditions. The flexibility and improved accuracy of the new model make it a valuable tool for reactor safety analysis, allowing for the simulation of different geometries encountered in advanced reactors. A system-level corrosion modeling capability is developed and implemented in SAM to support Lead Fast Reactor (LFR) development. Although the initial focus of this capability will be on LFR application, this can later be expanded to include other liquid metals such as Lead-Bismuth Eutectic (LBE) and PbLi. This report summarizes the common corrosion mitigation strategies and outlines the progress on implementing and validating a corrosion-oxidation model in SAM. Verification and validation of the corrosion-oxidation portion of the model was performed using analytical solution and measured data from samples tested in the non-isothermal pumped lead loop at IPPE Obninsk. The iron transport and corrosion/precipitation portion of the model was assessed using an analytical model and measured corrosion depths from a natural convection lead loop experiment performed at CEA. It is demonstrated that the model implemented in SAM performed well in these assessments.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Shear/Defocus Sensitivity of the Mid Infrared Channel (MIR) of the Composite Infrared Spectrometer (CIRS) for the Cassini Mission to Saturn

The Composite Infrared Spectrometer (CIRS) of the Cassini mission to Saturn has two interferometers covering the far infrared and mid infrared wavelength region. The mid infrared wavelength interferometer has a focal plane consisting of a germanium focus lens and HgCdTe array. System level calibration of the CIRS Flight Unit indicated a discrepancy between the expected and actual signal levels. Testing on the CIRS breadboard and Engineering Unit indicated that defocus of the germanium lens could significantly reduce the modulation efficiency of the interferometer in the presence of a moderate degree of wavefront shear. Defocus of the lens in the focal plane was of concern because of the temperature dependence of the index of refraction of germanium and our nominal operation temperature of 170 K. The shear/defocus interaction was extensively investigated and correlated to a newly developed analytical model, It was eventually determined that the CIRS instrument was in focus, had no appreciable wavefront shear and was operating near theoretical limits. The shear/defocus effect is however, of considerable interest, since it has not been described in previous literature on interferometers.

Martino, Anthony J.↗

Advective gas flow in bentonite: Development and comparison of enhanced multi-phase numerical approaches

Understanding the impact of repository gas, generated from degradation of waste and its interaction with the host rock, is essential when assessing the performance and safety function of long-term disposal systems for radioactive waste. Numerical models based on conventional multi-phase flow theory have historically been applied to predict the outcome and impact of gas flow on different repository components. However, they remain unable to describe the full complexity of the physical processes observed in water-saturated experiments (e.g., creation of dilatant pathways) and thus, the development of novel representations for their description is required when assessing fully saturated clay-based systems. This was the primary focus of Task A within the international cooperative project DECOVALEX-2019 (D-2019) and refinement of these approaches is the primary focus of this study (Task B in the current phase of DECOVALEX-2023). This paper summarises development of enhanced numerical representations of key processes and compares the performance of each model against high-quality laboratory test data. Experimental data reveals that gas percolation in water-saturated compacted bentonite is characterised by four key features: (i) a quiescence phase, followed by (ii) the gas breakthrough, which leads to a (iii) peak value, which is then followed by (iv) a negative decay. Three models based on the multiphase flow theory have been developed. These models can provide good initial values and reasonable responses for gas breakthrough (although some of them still predict a too-smooth response). Peak gas pressure values are in general reasonably well captured, although maximum radial stress differences are observed at 48 mm from the base of the sample. Here, numerical peak values of 12.8 MPa are predicted, whereas experimental values are about 11 MPa. These models are also capable of providing a reasonable representation of the negative pressure decay following peak pressure. However, other key specific features (such as the timing of gas breakthrough) still require a better representation. The model simulations and their comparison with experimental data show that these models need to be further improved with respect to model parameter calibration, the numerical representation of spatial heterogeneities in material properties and flow localisation, and the upscaling of the related physical processes and parameters. To further understand gas flow localisation, a new conceptual model has been developed, which shows that discrete channels can possibly be induced through the instability of gas-bentonite interface during gas injection, thus providing a new perspective for modeling gas percolation in low-permeability deformable media.

58 GEOSCIENCES↗

Modeling Temperature Profiles in the Pedestal of NSTX with Reduced Models

This paper describes new modeling capabilities for predicting H-mode pedestal profiles in spherical tokamaks. Temperature profiles for NSTX discharges 132543 and 132588 are modeled by coupling the \textsc{astra} transport solver with neoclassical transport and gyrokinetic-based reduced models for electron temperature gradient (ETG) and kinetic ballooning mode (KBM) instabilities. A quasi-linear surrogate model for ion-scale transport is developed using linear \textsc{gene} simulations, requiring only a single free parameter calibrated to one discharge. Time-evolving the temperatures with fixed density yields good agreement with experiments for both discharges. Systematic analysis of the transport mechanisms reveals that neoclassical transport is huge across the entire pedestal region for the ion channel. ETG turbulence is large in the plasma edge and low density gradient region, contributing substantially to the electron channel. However, KBM/MHD-like modes also drive significant transport in both the ion and electron thermal channels, making them essential for accurate pedestal modeling. Further refinements, including explicit E×B shear suppression and scaled ETG transport, produce quantitative but not qualitative improvements. This work lays the foundation for predictive modeling of future devices. This paper is on arxiv and has been submitted to Nuclear Fusion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Large Antenna Multifrequency Microwave Radiometer (LAMMR) system design

The large Antenna Multifrequency Microwave Radiometer (LAMMR) is a high resolution 4 meter aperture scanning radiometer system designed to determine sea surface temperature and wind speed, atmospheric water vapor and liquid water, precipitation, and various sea ice parameters by interpreting brightness temperature images from low Earth orbiting satellites. The LAMMR with dual linear horizontal and vertical polarization radiometer channels from 1.4 to 91 GHZ can provide multidiscipline data with resolutions from 105 to 7 km. The LAMMR baseline radiometer system uses total power radiometers to achieve delta T's in the 0.5 to 1.7 K range and system calibration accuracies in the 1 to 2 deg range. A cold sky horn/ambient load two point calibration technique is used in this baseline concept and the second detector output uses an integrated and dump circuit to sample the scanning cross-tract resolution cells.

King, J. L.↗

External calibration of polarimetric radar images using distributed targets

A new technique is presented for calibrating polarimetric synthetic aperture radar (SAR) images using only the responses from natural distributed targets. The model for polarimetric radars is assumed to be X = cRST where X is the measured scattering matrix corresponding to the target scattering matrix S distorted by the system matrices T and R (in general T does not equal R(sup t)). To allow for the polarimetric calibration using only distributed targets and corner reflectors, van Zyl assumed a reciprocal polarimetric radar model with T = R(sup t); when applied for JPL SAR data, a heuristic symmetrization procedure is used by POLCAL to compensate the phase difference between the measured HV and VH responses and then take the average of both. This heuristic approach causes some non-removable cross-polarization responses for corner reflectors, which can be avoided by a rigorous symmetrization method based on reciprocity. After the radar is made reciprocal, a new algorithm based on the responses from distributed targets with reflection symmetry is developed to estimate the cross-talk parameters. The new algorithm never experiences problems in convergence and is also found to converge faster than the existing routines implemented for POLCAL. When the new technique is implemented for the JPL polarimetric data, symmetrization and cross-talk removal are performed on a line-by-line (azimuth) basis. After the cross-talks are removed from the entire image, phase and amplitude calibrations are carried out by selecting distributed targets either with azimuthal symmetry along the looking direction or with some well-known volume and surface scattering mechanisms to estimate the relative phases and amplitude responses of the horizontal and vertical channels.

Yueh, Simon H.↗

SSH-2 measurements of cirrus at 18-28 micrometers from the King Air during FIRE 2

In November of 1991, the First ISCCP (International Satellite Cloud Climatology Project) Regional Experiment (FIRE) Phase II cirrus study took place at Coffeyville, Kansas. The field experiment incorporated instrumentation from surface, aircraft, and satellite to attempt to define the optical, radiative, and microphysical characteristics of these high altitude, predominantly ice clouds. The NCAR King Air research aircraft was outfitted with a variety of radiative and microphysical instrumentation for the FIRE II project. Included for this project was the SSH-2, a 16-channel passive radiometer. The SSH-2 was originally designed as a space-qualified infrared (IR) temperature and water vapor sounder for deployment onboard the Defense Meteorological Satellite Program (DMSP) series of environmental satellites. For this experiment, only those channels associated with the water vapor profiling function have been examined although downwelling radiance measurements were taken at all channels during the project. With supporting information from the aircraft telemetry observations it may be possible to relate these SSH-2 measurements to cloud radiative and microphysical properties. The following sections will describe the spectral characteristics of the instrument, the calibration scheme used to convert the raw measured counts into calibrated radiances, and the case studies that will be covered in this paper. This will be followed by a discussion of the results of this preliminary investigation and a description of future work to be done.

Griffin, Michael K.↗

A 1D Lyman-alpha profile camera for plasma edge neutral studies on the DIII-D tokamak

A one dimensional, absolutely calibrated pinhole camera system was installed on the DIII-D tokamak to measure edge Lyman-alpha (Ly-α) emission from hydrogen isotopes, which can be used to infer neutral density and ionization rate profiles. The system is composed of two cameras, each providing a toroidal fan of 20 lines of sight, viewing the plasma edge on the inboard and outboard side of DIII-D. The cameras’ views lie in a horizontal plane 77 cm below the midplane. At its tangency radius, each channel provides a radial resolution of ~2 cm full width at half maximum (FWHM) with a total coverage of 22 cm. Each camera consists of a rectangular pinhole, Ly-α reflective mirror, narrow-band Ly-α transmission filter, and a 20 channel AXUV photodetector. The combined mirror and transmission filter have a FWHM of 5 nm, centered near the Ly-α wavelength of 121.6nm and is capable of rejecting significant, parasitic carbon-III (C-III) emission from intrinsic plasma impurities. To provide a high spatial resolution measurement in a compact footprint, the camera utilizes advanced engineering and manufacturing techniques including 3D printing, high stability mirror mounts, and a novel alignment procedure. Absolutely calibrated, spatially resolved Ly-α brightness measurements utilize a bright, isolated line with low parasitic surface reflections and enable quantitative comparison to modeling to study divertor neutral leakage, main chamber fueling, and radial particle transport.

Ionization Rate↗

A 1D Lyman-alpha Profile Camera for Plasma Edge Neutral Studies on the DIII-D Tokamak

A one dimensional, absolutely calibrated pinhole camera system was installed on the DIII-D tokamak to measure edge Lyman-alpha (Ly-a) emission from hydrogenic isotopes which can be used to infer neutral density and ionization rate proles. The system is composed of two cameras, each providing a toroidal fan of twenty lines of sight, viewing the plasma edge on the inboard and outboard side of DIII-D. The cameras' views lie in a horizontal plane 77 cm below the midplane. At its tangency radius, each channel provides a radial resolution of approximately 2 cm full width at half maximum (FWHM) with a total coverage of 22 cm. Each camera consists of a rectangular pinhole, Ly-a reflective mirror, narrow-band Ly-a transmission fiter, and a 20 channel AXUV photodetector. The combined mirror and transmission fiter have a FWHM of 5 nm, centered near the Ly-a wavelength of 121.6 nm and is capable of rejecting significant, parasitic carbon-III (C-III) emission from intrinsic plasma impurities. To provide a high spatial resolution measurement in a compact footprint, the camera utilizes advanced engineering and manufacturing techniques including 3D printing, high stability mirror mounts, and a novel alignment procedure. Absolutely calibrated, spatially resolved Ly-a brightness measurements utilize a bright, isolated line with low parasitic surface reflections and enable quantitative comparison to modeling to study divertor neutral leakage, main chamber fueling and radial particle transport.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

RST CGI: Final Verification and Calibration of Prism and Polarizer Flight Units

As part of its technology demonstration, the Nancy Grace Roman Space Telescope Coronagraph Instrument (CGI) will demonstrate point source spectroscopy and polarization measurements of disks. The spectroscopy mode is a zero-deviation Amici prism and slit which is deployed to the planet position after an imaging detection. The Wollaston prism polarization optics allow for imaging two orthogonal polarization states simultaneously. The CGI spectral characterization modes, designed and built at Goddard Space Flight Center (GSFC), have a spectral resolution of R50 in two 15% bandpass centered at 660nm and 730nm. There are duplicate Wollaston prism channels, clocked 45 degrees with respect to one another to completely characterize the instrument polarization effects and recover the Stokes parameters of the targeted disk. The Wollaston design and optical elements are a contribution by the Japanese Aerospace Exploration Agency, with final alignment and testing being done at GSFC. The spectroscopy mode is optimized to target Methane absorption features around 730nm, keeping the spectral resolution as low as possible to improve the signal-to-noise ratio and hence reduce detection time. We highlight the requirements for these modes, the ground-to-orbit calibration process, and the operations required to use a deployable slit on a CGI point source in the presence of pointing error. We also provide further detail on the optomechanical design, testing results from the final as-built flight units, verification process, and performance of the as-built flight assemblies.

high contrast imaging↗

Thermal band characterization of LANDSAT-4 thematic mapper

The TM band 6 shutter background and the 34.7 C internal black body signal were measured over 50 day dates. Variability of the shutter background temperature was from 7 C to 11 C. For ten specific images, the digital counts of the calibration data were measured. The average pulse value of the black body peak decreased from 174 to 149 counts while the shutter background counts varied as a function of shutter temperature from 77 to 85. Relative internal gains between the four channels were calculated and compared to prelaunch values. They showed gains over 9 months of up to 5%. Frequency histograms of number of pixels vs. digital counts from a night scene were used to determine gain relative to the mean and to discern a systematic along-scan pattern in a difference between forward and reverse scan counts of up to 0.5. A corrected digital image was obtained. A temperature estimate for and area of Lake Erie of 18.5 C to 19.9 C was obtained. Local temperature records showed 21 C.

Lansing, J. C.↗

Inter-Comparison of Terra and Aqua MODIS

Nearly identical copies of the Moderate Resolution Imaging Spectroradiometer (MODIS) have been operating on-board the NASA's Earth Observing System (EOS) Terra and Aqua satellites since their launches in December 1999 and May 2002, respectively. Each MODIS has 20 reflective solar bands (RSB) with center wavelengths ranging from 0.41 to 2.1 micrometers and 16 thermal emissive bands (TEB) from 3.7 to 14.4 micrometers. The absolute radiometric accuracy requirements (1 sigma) at the typical spectral radiance levels are plus or minus 2% for the RSB for the RSB reflectance factors and plus or minus 5% for the RSB radiance products. With few exceptions, the TEB requirements are plus or minus 1%. The sensor's on-orbit radiometric calibration is performed by the on-board calibrators, including a solar diffuser (SD) and a solar diffuser stability monitor (SDSM) system for the RSB and a V-groove flat panel blackbody (BB) for the TEB. In addition, the Moon has been extensively used by both Terra and Aqua MODIS to support their on-orbit calibration and characterization. This paper presents MODIS lunar calibration methodology and inter-comparison of Terra and Aqua MODIS in the VIS/NIR spectral regions. Current results from lunar observations show that the calibration difference between the two sensors is less than plus or minus 1%. Also discussed in this paper are the approaches and results of inter-comparison of Terra and Aqua MODIS in the TEB using closely matched thermal infrared (TIR) channels on the Advanced Very High Resolution Radiometer (AVHRR) at 11 and 12 micrometers.

Xiong, X.↗