Spin-optomechanical cavity interfaces by deep subwavelength phonon-photon confinement

A central goal of quantum information science is transferring qubits between space, time, and modality. Spin-based systems in solids are promising quantum memories, but high-fidelity transfer of their quantum states to telecom optical fields remains challenging. Here, we introduce a phonon-mediated interface between spins in a diamond nanobeam optomechanical crystal and telecom optical fields by a simultaneous deep-subwavelength confinement of optical and acoustic fields with mode volumes $V_{\textrm{mech}}$$/Λ^3_\textrm{p} ~ 10^{-5}$ and $V_{\textrm{opt}}$$/λ^3 ~ 10^{−3}$, respectively. This confinement boosts the spin-mechanical coupling rate of Group-IV silicon vacancy (SiV − ) centers by an order of magnitude to ~ 32 MHz while retaining high acousto-optical couplings. The optical cavity couples to the spin irrespective of the emitter’s native excited states, avoiding spectral diffusion. Using Quantum Monte Carlo simulations, we estimate heralded entanglement fidelities exceeding 0.96 between two such interfaces. We anticipate broad utility beyond diamond emitter-telecom systems to most solid-state quantum memories.

Raniwala, Hamza [Massachusetts Inst. of Technology↗

Demonstration of a 20‐W membrane‐external‐cavity surface‐emitting laser for sodium guide star applications

Abstract We present a record 20‐W continuous‐wave output power membrane‐external‐cavity surface‐emitting laser (MECSEL) double‐bonded to silicon carbide (SiC) heat spreaders emitting around 1178 nm. We achieved a maximum slope efficiency of 27.7% and an optical‐to‐optical efficiency of 26.7%. By utilising an intracavity birefringent filtre, the wavelength was tuned over 75 nm and maximum output power of 12.7 W was recorded at 1178 nm. This study shows the potential of MECSELs to achieve high‐performance and cost‐effective optically pumped semiconductor disk lasers targeting applications in sodium guide stars.

Priante, D.↗

Structure and dynamics of hydrodynamically interacting finite-size Brownian particles in a spherical cavity: Spheres and cylinders

The structure and dynamics of confined suspensions of particles of arbitrary shape are of interest in multiple disciplines from biology to engineering. Theoretical studies are often limited by the complexity of long-range particle-particle and particle-wall forces, including many-body fluctuating hydrodynamic interactions. Here, we report a computational study on the diffusion of spherical and cylindrical particles confined in a spherical cavity. We rely on an immersed-boundary general geometry Ewald-like method to capture lubrication and long-range hydrodynamics and include appropriate non-slip conditions at the confining walls. A Chebyshev polynomial approximation is used to satisfy the fluctuation-dissipation theorem for the Brownian suspension. We explore how lubrication, long-range hydrodynamics, particle volume fraction, and shape affect the equilibrium structure and the diffusion of the particles. It is found that once the particle volume fraction is greater than 10%, the particles start to form layered aggregates that greatly influence particle dynamics. Hydrodynamic interactions strongly influence the particle diffusion by inducing spatially dependent short-time diffusion coefficients, stronger wall effects on the particle diffusion toward the walls, and a sub-diffusive regime-caused by crowding-in the long-time particle mobility. The level of asymmetry of the cylindrical particles considered here is enough to induce an orientational order in the layered structure, decreasing the diffusion rate and facilitating a transition to the crowded mobility regime at low particle concentrations. Our results offer fundamental insights into the diffusion and distribution of globular and fibrillar proteins inside cells.

36 MATERIALS SCIENCE↗

Standoff detection of chemical plumes from high explosive open detonations using a swept-wavelength external cavity quantum cascade laser

A swept-wavelength external cavity quantum cascade laser (ECQCL) is used to perform standoff detection of combustion gases in a plume generated from an outdoor high-explosive (HE) open detonation. The swept-ECQCL system was located at a standoff distance of 830 m from a 41kg charge of LX-14(polymer-bonded high explosive) and was used to measure the infrared transmission/absorption through the post-detonation plume as it propagated through the beam path. The swept-ECQCL was operated continuously to record broadband absorption spectra at 200hz rate over a spectral range from 2050 to 2230 cm -1 (4.48 - 4.88 μm). Fitting of measured spectra was used to determine time-resolved column densities of CO, CO 2 , H 2 O, and N 2 O. Analysis of visible video imagery was used to provide timing correlations and to estimate plume dimensions, from which gas mixing ratios were estimated. Measured emission factors and modified combustion efficiency show good agreement with previously reported values.

47 OTHER INSTRUMENTATION↗

Amplified spontaneous emission from europium-based molecular complexes coupled to photonic crystal cavities

Rare-earth ion-based materials bear many remarkable optical properties that render them highly appealing for lighting and quantum-related applications. However, their small oscillator strength and weak emission often pose limitations. Here, in this work, we synthesize and couple Eu(III)-based molecular complexes to nanobeam photonic crystals supporting air modes. A reasonable spatial overlap between the molecular complexes and cavity modes leads to an average spontaneous emission coupling efficiency of 0.19. Our pump power-dependent photoluminescence measurements evidence amplified spontaneous emission from the molecular complexes with an amplification threshold as low as 4.4 W/cm 2 , likely benefiting from the efficient coupling. These findings suggest that integrating rare-earth ion-based molecular complexes with photonic structures could be a viable approach for regulating their emission characteristics for particular applications.

36 MATERIALS SCIENCE↗

Oxide dissolution and oxygen diffusion scenarios in niobium and implications on the Bean–Livingston barrier in superconducting cavities

We generalize a native Nb 2 O 5 dissolution model [G. Ciovati, Appl. Phys. Lett. 89, 022507 (2006)] to sequential overlayer dissolutions, multilayer dissolution, and realistic temperature profiles, which may be applicable to other materials. The model is applied to secondary ion mass spectrometry depth profile measurements for varying temperature profiles and two-step oxide dissolution in Nb and found to agree well. In the context of the Meissner screening response due to impurity profiles on the length scale of the London penetration depth, the shallow diffusion of O impurities results in a substantial decrease in the peak supercurrent density near the surface. In this framework, oxide dissolution and oxygen diffusion can account for a rise in peak supportable magnetic field in SRF cavities with baking time and a suppression after the optimal baking time is reached, in good agreement with peak-field baking temperatures and times as well as recent quench field measurements.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Cavity-enhanced high-order harmonic generation for high-performance time-resolved photoemission experiments

Recent breakthroughs in high repetition-rate extreme ultraviolet (XUV) light sources and photoelectron analyzers have led to dramatic advances in the performance of time-resolved photoemission experiments. In this perspective article, we discuss the application of cavity-enhanced high-order harmonic generation, with repetition rates exceeding 10 MHz, to photoemission experiments using advanced endstations incorporating time-of-flight photoelectron analyzers. We discuss recent results, perspective on future areas for further technological improvement, and the wide array of science enabled by ultrafast XUV photoemission experiments, now in a qualitatively new regime.

Allison, Thomas K. (ORCID:0000000302898830)↗

Brewster angle-cavity ringdown spectroscopy for low temperature plasma measurements in multiphases

Here we report on the development of a Brewster angle-cavity ringdown spectroscopy (BA-CRDS) system for low temperature plasma diagnostics. The system can measure gas species in solutions, with a detection limit (minimum detectable absorbance) of 9.1 × 10 -5 , which is equivalent to a detection limit of 0.04 parts per billion for measuring OH radicals in water at 308 nm. With higher reflectivity ringdown mirrors and improved design of a Brewster angle cell, the detection limit can potentially be up to 10 -6 or lower. In this exploratory study, the absorption cross sections of HgBr 2 and H 2 O 2 in the aqueous phase at 256 nm are measured to be (1.8 ± 0.1) × 10 -18 cm 2 and (5.2 ± 0.5) × 10 -20 cm 2 , respectively. Furthermore, temporal profiles of absorbance from distilled water, HgBr 2 , and H 2 O 2 solutions when interacting with a helium atmospheric plasma jet are individually characterized at different plasma powers, gas flow rates, and/or solute concentrations. The observed linear temporal profiles of absorbance from the plasma-interacted water suggest formation of H 2 O 2 from plasma-generated OH radicals, while the nonlinear temporal profiles from the plasma-treated HgBr 2 solutions reveal possible removal of HgBr 2 by OH radicals. Our results demonstrate that the new BA-CRDS system is a powerful tool for quantification of reactive plasma species in multiphases or other complex settings.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A simple, flexible technique for RF cavity wake-field calculations

It is typical in the accelerator field to model machine components, especially RF cavities, as parallel RLC resonators. In the interest of simulating and diagnosing beam instabilities, knowledge of the time-domain voltage waveform over an equivalent resonator by a bunch current often proves useful. This waveform may be found by convolving the bunch current with the RLC resonator impulse response. While analytical and quasi-analytical expressions are available in this regime for common distributions such as the Gaussian, analogous results for less standard distributions are difficult to obtain using direct methods, which opens the door for the development of a more generalized technique. In this paper, a formulation is created that allows for the simple computation of the time-domain voltage waveform of and RLC resonator. The formulation uses the Cauchy Residue Theorem to extract the convolution result from the Fourier Domain, and it only requires that the current distribution Fourier Transform be holomorphic and known at one specific evaluation point. This greatly simplifies the computation of the time domain voltage for a large amount of bunch distributions both common and uncommon.

43 PARTICLE ACCELERATORS↗

Quantum states of cylindrical surface charge density for modeling plasmonic circuit elements: Nanowires, nanorods, cavities, and waveguides

Nanostructures in the form of ellipsoids, prolate spheroids, rings, and cylinders are known to exhibit resonant surface and cavity modes with applications in nanophotonics and plasmonics and, more recently, in novel quantum experiments, in which control of plasmons and their interactions with plasmons, photons, phonons, excitons, and quantum emitters are desired. Nanorods and nanowires are examples of plasmonic structures with spectral properties of potential use as interconnects and circuit components. Additionally, estimates of the surface properties of these components are needed in circuit design and integrated systems. Here, we present a quantum Hamiltonian for the cylindrical surface charge density. We then study the photon excitation of plasmons on the cylindrical surface and calculate their scattering and radiative decay rate. Nonradiative decay of plasmons induces an efficient heating of the nanoparticle and can photoacoustically excite mechanical oscillations. Computational calculations are also presented for the plasmonic modes and the ensuing excitations of nanomechanical eigenmodes of nanoparticles with near-cylindrical symmetries.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Utilizing machine learning to improve the precision of fluorescence imaging of cavity-generated spin squeezed states

We present a supervised learning model to calibrate the photon collection rate during the fluorescence imaging of cold atoms. The linear regression model finds the collection rate at each location on the sensor such that the atomic population difference equals that of a highly precise optical cavity measurement. This 192 variable regression results in a measurement variance 27% smaller than our previous single variable regression calibration. The measurement variance is now in agreement with the theoretical limit due to other known noise sources. This model efficiently trains in less than a minute on a standard personal computer's CPU and requires less than 10 min of data collection. Furthermore, the model is applicable across a large change in population difference and across data collected on different days.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Microscopic examination of rf-cavity-quality niobium films through local nonlinear microwave response

The performance of superconducting radio-frequency (SRF) cavities is sometimes limited by local defects. To investigate the rf properties of these local defects, especially those that nucleate rf magnetic vortices, a near-field magnetic microwave microscope is employed. Local third-harmonic response ( P 3 f ) and its temperature dependence and rf power dependence are measured for one Nb / Cu film grown by direct current magnetron sputtering (DCMS) and six Nb / Cu films grown by high-power impulse magnetron sputtering (HiPIMS) with systematic variation of deposition conditions. Five out of the six HiPIMS Nb / Cu films show a strong third-harmonic response that is likely coming from rf vortex nucleation due to a low- T c surface defect with a transition temperature between 6.3 and 6.8 K, suggesting that this defect is a generic feature of air-exposed HiPIMS Nb / Cu films. A phenomenological model of surface-defect grain boundaries hosting a low- T c impurity phase is introduced and studied with time-dependent Ginzburg-Landau (TDGL) simulations of probe-sample interaction to better understand the measured third-harmonic response. The simulation results show that the third-harmonic response of rf vortex nucleation caused by surface defects exhibits the same general features as the data, including peaks in third-harmonic response with temperature, and their shift and broadening with higher microwave amplitude. We find that the parameters of the phenomenological model (the density of surface defects that nucleate rf vortices and the depth an rf vortex travels through these surface defects) vary systematically with film deposition conditions. From the point of view of these two properties, the Nb / Cu film that is most effective at reducing the nucleation of rf vortices associated with surface defects can be identified. Published by the American Physical Society 2024

Wang, Chung-Yang (ORCID:0000000184299633)↗

A Miniaturized, High-Bandwidth Optical Fiber Fabry–Perot Cavity Vibration Sensor Demonstrated up to 800 °C

A typical structural health monitoring technique involves measuring the vibrational characteristics of components or systems to detect signs of degradation or damage. Many industrial applications require engineered systems to safely operate under extreme, high-temperature environments that pose challenges not only to materials but also to sensors that would be used for structural health monitoring. Here, in this study, miniaturized optical Fabry-Perot cavities (FPCs) were developed and tested as a means of measuring the resonant frequencies of metal components that are most relevant to extreme-environment applications. Two of the three candidate FPC designs tested up to 800 ° C provided accurate measurements (validated by theoretical models and laser Doppler vibrometry) of the fundamental vibrational mode of the specimen to which each was bonded, although both sensors failed during thermal cycling. An analysis of the reflected optical spectrum from the FPC and X-ray computed tomography revealed two opportunities to improve the sensor reliability. First, the Cu optical fiber coating that was used could either be replaced with a more oxidation-resistant material or protected with commercially available films. Second, the adhesives used to bond the fibers to metal capillaries and establish the FPC could be replaced with a more robust solution, although the Resbond 907TS adhesive appeared to outperform Resbond 907.

Birri, Anthony [Oak Ridge National Laboratory (ORN↗

Fiber Optic Temperature Sensor Using Dual Air- Filled Fabry-Pérot Cavities With Variable Pressure

We present an approach for high temperature measurement using a pair of fiber-optic Fabry–Pérot (FP) cavities filled with gas of identical but variable pressure. One of the FPs (reference FP) is placed in the cold zone with a known temperature. The temperature of the measuring FP can be deduced by the spectral fringe shift vs. pressure of the two FPs. This method does not require measurement of the pressure or the knowledge of the optical properties of the gas. The use of gas as the sensing material and the measurement mechanism also implies long-term stability and eliminates the cross-sensitivity to strain. We fabricated the sensors and tested them for measuring temperature up to 800 °C. Here, the sensor shows good linearity in the range. Long-term test conducted at 800 °C exhibited the stability of the sensor with fluctuations of ≤0.3% over a duration exceeding 100 hours.

42 ENGINEERING↗

Characterizing Flow Instabilities During Transient Events in the Turbine Rim Seal Cavity

Abstract Gas turbine engine design requires considerations not only for long-term steady operation but also for critical transient events. Aircraft engines undergo significant stress during takeoff and landing, while power generation turbines must be flexible for hot restarts as renewable energy sources come online and offline. During these transient cycles, engines sustain wear and degradation that can lead to a reduction in the lifespan of their components and more frequent, costly maintenance. Cooling flows are often used to mitigate these effects, but can lead to complex and problematic flow interactions. This study uses high-frequency response pressure probes and heat flux gauges in the rim seal cavity of a one-stage research turbine to characterize the properties of large-scale flow structures during transient operation. A continuous-duration turbine testing facility provides the ability to assess the importance of these transients by first reaching steady-state operation before imposing transient behaviors. Although previous studies have conducted similar measurements for steady purge flows and wheel speeds, varying these parameters to simulate transient effects revealed several unique phenomena not identifiable with discrete steady measurements. The measurement approach connects the varied transient parameter to the behavior of the flow structures to enable a better understanding of the type of instability observed and the root cause of its formation. In particular, a relationship between instability cell formation and rim sealing effectiveness was identified using experimental data and was supported through computational simulations.

Engineering↗