Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “capacity test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Electrolyte Vapor Induced Passivation and Transition Metal Redox on Electrode Active Materials

The gaseous environment that battery electrodes are exposed to is critical to their electrochemical performance, and yet, the impact of vapor-phase components in the glovebox is relatively unexplored. In this study, we examine how the surface of Li 4 Ti 5 O 12 and LiFePO 4 composite electrodes evolve upon exposure to 1 M LiPF 6 in ethylene carbonate:dimethyl carbonate electrolyte vapors in an argon-filled glovebox. Spatially resolved X-ray photoemission electron microscopy and X-ray photoelectron spectroscopy reveal that even brief (15 minutes) contact with electrolyte vapor initiates the formation of a LiF film and changes the oxidation state of transition metals at the particle surface. Notably, these modifications occur selectively on active material particles and not on binder or conductive carbon, underscoring the specificity of vapor-induced reactions. Prolonged exposure to electrolyte vapor over the course of 1 week yields thicker, more chemically complex interphases containing both LiF and lithium oxyfluorophosphate species (Li x PO y F z ). Subsequent electrochemical testing shows that vapor-induced passivation layers influence first cycle capacities, lithium (de)insertion overpotentials, and charge-transfer resistance values. In conclusion, these results indicate that vapor–electrode interactions may be a source of variability in electrochemical behavior over time and suggest that other, more reactive electrode materials may also be susceptible to interactions with electrolyte vapor.

36 MATERIALS SCIENCE↗

RE-INTEGRATE EMT Simulation Software: Graph Convolutional Network for Sparse Matrix Pattern Detection

The increasing complexity of power networks, driven by proliferation of inverters, presents analytical challenges that simplified models often fail to capture, necessitating Electromagnetic Transient (EMT) simulations. EMT models are represented as discretized differential-algebraic equations (DAEs), forming a linear system Ax = b that is computationally intensive to solve. Due to inherent sparsity of adjacency matrix A, distinct patterns emerge that, when accurately identified, enable efficient solver selection to minimize computation time. However, identifying ideal pattern is complicated by numerous reordering algorithms and limited structural insights. To address this, we introduce a Graph Convolutional Network (GCN) model for classifying sparse matrix patterns common in power system analysis. The model, achieving 96% test accuracy, is validated using PV plant models of 125 MW capacities connected to New England 39-bus transmission system (TS), and further scaled to a 4,992-bus network with 384 PV plants, yielding 191, 616 × 191, 616 sized A matrix. For all cases, the GCN model accurately identifies the matrix’s intrinsic sparse pattern, demonstrating its potential to enhance solver performance in EMT analysis.

Hossain, Md Rifat [Florida International Universit↗

Assessing Electrolyte Fluorination Impact on Calendar Aging of Blended Silicon-Graphite Lithium-Ion Cells Using Potentiostatic Holds

Silicon-based lithium-ion batteries have started to meet cycle life metrics, but they exhibit poor calendar life. Here, electrolyte fluorination impact on calendar fade of blended silicon-graphite anodes is explored using a LiPF 6 in EC:EMC:FEC electrolyte vs LiBOB in EC:EMC electrolyte. We utilize a combined experimental-modeling approach applying potentiostatic voltage holds (V-hold) to evaluate electrolyte suitability for calendar life in a shortened testing timeframe (~2 months). Our theoretical framework deconvolutes the irreversible parasitic capacity losses (lithium lost to the solid electrolyte interphase) from the V-hold electrochemical data. Unfluorinated electrolyte (dominant LiBOB reduction) exhibits higher cell resistance as compared to fluorinated electrolyte (dominant FEC reduction). Both systems have similar irreversible capacities during the voltage hold duration with slower rate of parasitic capacity loss for the LiBOB system. Extrapolation of the parasitic losses to end of life capacity fade of 20% shows LiBOB electrolyte outperforming LiPF 6 electrolyte in calendar life. The results demonstrate the applicability of the V-hold protocol as a rapid material screening tool providing semi-quantitative calendar lifetime estimates.

25 ENERGY STORAGE↗

Auto-BLAST (AutoBLAST) [SWR-20-93]

Battery life modeling often involves a lot of manual parameter fitting and is not easy for users to adopt the model and use it. To reduce the difficulties for users to adopt battery lifetime models, an automatic battery lifetime modeling analysis and simulation tool suite, Auto-BLAST, has been developed. Auto-BLAST includes a lithium-loss-base life model, a battery electric model, and an algorithm which automatically fits all key parameters in the electric and life models using user provided data. The models and algorithm are packaged into two user-friendly GUIs, Auto-LifeMod, for easy battery life prognostic model fitting and Auto-LifeSim, for easy battery lifetime simulation. The lithium-loss-based life model adopts a similar model framework that models degradations using aging rate models, using battery cycling data to predict battery degradation and expected lifetime. The electric model is an equivalent circuit model which simulates battery voltage responses based on current/power demand profiles. The auto-fitting algorithm uses the user-input data to generate custom battery life model(s). Two GUIs, wrapping around the life model and the auto-fitting algorithm, provide friendly interfaces for users to generate a life model and use it for case study. One GUI requires summary data from accelerated battery life degradation tests as an input and produces battery life models predicting (a) capacity degradation, and (b) resistance growth of the battery. The GUI displays the electrical model response and the input experimental data against the life model predictions with fitted model parameters and fitting error. The GUI also generates an output file to save the fitted model parameters. The second GUI uses the life model from the first GUI and a user-defined battery cycling profile to predict battery lifetime degradation and expected lifetime. Predicted capacity and resistance vs. time are plotted in the GUI and saved to output file. There is a user guide for both GUIs

Mishra, Partha↗

Safeguards by Design Projects (Final Report-FY-22)

This University Engagement project challenged engineering students at universities, that do not have Bachelor degree programs in nuclear engineering but do have research reactors and some nuclear engineering coursework, to incorporate Safeguards by Design concepts into their Senior Capstone Design Project. This University Engagement project was part of the U. S. Department of Energy’s (DOE) National Nuclear Security Administration (NNSA), Office of Defense Nuclear Nonproliferation, Office of International Nuclear Safeguards, Next Generation Safeguards Initiative (NGSI), Human Capital Development (HCD): University Engagement Program. This program exposed university students with Mechanical Engineering majors and Nuclear Engineering minors to the concepts of international nuclear safeguards. In FY22, three teams at the University of Rhode Island and two teams at the University of Texas - Austin participated in researching, designing, building, and testing projects to support international nuclear safeguards measurements or verification. The projects involved engaging in activities at the university’s research reactors. All the projects engaged students with prototyping a design and/or tool for application at the Universities’ reactor. At the end of the course, most of the students expressed the experience was positive and they learned more about international nuclear safeguards and applying requirements than they had previously encountered. This school year the projects were further complicated by the COVID-19 pandemic. Both universities had limited in classes on campus, still relying on Zoom classes, and limited direct student/professor interactions. Furthermore, Los Alamos National Laboratory (LANL) greatly restricted travel, therefore making it impossible to visit the students at the end of the semester for the review of their design projects. The final design and review meeting for the projects happened via meetings over the internet. Additionally, the teams did build and test some prototypes but could only do so in a limited capacity.

42 ENGINEERING↗

Development and Optimization of a Multi-Functional SCR-DPF Aftertreatment System for Heavy-Duty NOX and Soot Emission Reduction

The objective of this project is to develop a strategy for the integration of catalytic NOX emission control and particulate matter emission control into a single device for the successful application to heavy-duty on-road diesel engine exhaust aftertreatment. The critical attributes of such a device, for successful application to PACCAR fleet, are as follows: 1. Must have sufficient filtration efficiency and successfully demonstrate soot management strategies (i.e., oxidation) to be economically attractive and regulatory compliant for particulate matter abatement. 2. In particular, the integrated device must retain sufficiently high soot oxidation capacity with NO2 (i.e., passive soot oxidation) across an applicable engine test cycle to be economically attractive. 3. Must exhibit sufficient catalytic NOX reduction activity in an economically-attractive fashion that is regulatory compliant.

54 ENVIRONMENTAL SCIENCES↗

Advanced Reactors Integrated Energy System: Thermal Energy Storage Island Design

The main topic of this research is integrated energy systems (IES) designed for pairing industrial thermal energy loads with advanced reactors (ARs). The Idaho National Laboratory (INL) Crosscutting Technology Development IES program and the National Reactor Innovation Center (NRIC) are seeking to develop, design, and construct an AR-IES demonstration platform that couples the thermal output from an AR operating at the INL/NRIC Demonstration of Microreactor Experiments (DOME) test bed in the Experimental Breeder II dome to a variable capacity load emulator (i.e., air-cooled radiator) and sensible thermal energy storage (TES) via a molten salt thermal energy transfer fluid. In the rapidly evolving landscape of energy supply and distribution, flexibility has emerged as a prized attribute, surpassing the traditional notions of stability and baseload generation capability. This shift in priorities is particularly evident in the context of nuclear power plants (NPPs), where adaptability over constant output is becoming more important. As our energy infrastructure and resources embraces the rise of distributed energy generation, the inherent variability in net demand continues to grow. Moreover, the use of nuclear energy as a source of heat for decarbonizing the industrial sector is becoming a very pressing topic. In such environment, advanced NPPs are poised to enter a more competitive energy market, delivering both, flexible electricity and heat. This shift motivates the exploration of TES systems, designed to empower NPPs with nimble responsiveness to market fluctuations, flexible heat delivery capabilities, and redefine their role in the energy field. TES systems offer the unique advantage of storing nuclear energy in its original form as heat, thereby affording unparalleled flexibility in its subsequent utilization.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Enabling CO 2 Isothermal Compression Using Liquid Piston and Integrated Gas Cooler

This report outlines the development of a near-isothermal liquid piston compressor. Initially, a proof-of-concept experiment was conducted to validate the feasibility and potential of near-isothermal compression. A first-of-its-kind near-isothermal liquid piston compressor was then successfully built and tested. Additionally, a Matlab-based transient model was developed to capture performance trends accurately. These efforts laid the groundwork for developing a second-generation prototype with enhanced efficiency and design. Subsequent field tests at the Helix Innovation Center in Ohio demonstrated a cooling capacity of 2 kW with a COP of 1.64 at an ambient temperature of 25°C. An improved model was also created to suggest different heat exchanger geometries for better compression efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modular Hydronic Room Conditioning System (CRADA NFE-24-10120 Final Report)

This project presents the development and validation of high-fidelity numerical models for fin-tube heat exchangers to enable accurate performance prediction and informed design optimization. The modeling framework integrates detailed geometric specifications, thermophysical property data, and system-level constraints to simulate the heat exchanger’s behavior under a range of operating conditions. The model is calibrated using real-world product specifications and validated against experimental data collected from controlled cooling and heating tests. In cooling mode, the model captures the overall trends in capacity and outlet air temperature but tends to underpredict latent effects, especially at lower air flow rates. In heating mode, the simulation consistently overestimates both the thermal capacity and outlet air temperature, indicating the need for refinement in air-side heat transfer assumptions. Despite these deviations, the model provides a solid foundation for optimization, allowing key design variables to be tuned within physical and performance-based constraints. This research advances the ability to simulate, validate, and optimize fin-tube heat exchanger designs with greater confidence and efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modular Hydronic Room Conditioning System

This project presents the development and validation of high-fidelity numerical models for fin-tube heat exchangers to enable accurate performance prediction and informed design optimization. The modeling framework integrates detailed geometric specifications, thermophysical property data, and system-level constraints to simulate the heat exchanger’s behavior under a range of operating conditions. The model is calibrated using real-world product specifications and validated against experimental data collected from controlled cooling and heating tests. In cooling mode, the model captures the overall trends in capacity and outlet air temperature but tends to underpredict latent effects, especially at lower air flow rates. In heating mode, the simulation consistently overestimates both the thermal capacity and outlet air temperature, indicating the need for refinement in air-side heat transfer assumptions. Despite these deviations, the model provides a solid foundation for optimization, allowing key design variables to be tuned within physical and performance-based constraints. This research advances the ability to simulate, validate, and optimize fin tube heat exchanger designs with greater confidence and efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Vegetation density as deduced from ERTS-1 MSS response

Reflectance from vegetation increases with increasing vegetation density in the 0.75- to 1.35 micron wavelength interval. Therefore, ERTS-1 bands 6 (0.7 to 0.8 micron) and 7 (0.8 to 1.1 micron) contain information that should relate to the probable yield of crops and the animal carrying capacity of rangeland. The results of an experiment designed specifically to test the relations among leaf area index (LAI), plant population, plant cover and plant height, and the ERTS-1 MSS responses for 3 corn, 10 sorghum, and 10 cotton fields are given. Plant population was as useful as LAI for characterizing the sorghum and corn fields, and plant height was as good as LAI for characterizing cotton fields. These findings generally support the utility of ERTS-1 data for explaining variability in green biomass, harvestable forage and other indicators of productivity.

Wiegand, C. L.↗

Performance investigations of liquid-metal heat pipes for space and terrestrial applications

The high heat transfer capacity of liquid-metal heat pipes is demonstrated in performance tests with mercury, potassium, sodium, and lithium working fluids and wick structures which serve to minimize liquid pressure losses and vapor/liquid interactions. Appropriate wicks for horizontal and vertical operation are described. It is shown that heat-transfer with these wicks is limited by vapor flow effects. Examples are given of particular effects associated with a long adiabatic section between evaporator and condenser and with a heat source of uniform temperature as opposed to a source of uniform power.

Kemme, J. E.↗

A high voltage electrical power system for low Earth orbit applications

The results of testing a high voltage electrical power system (EPS) breadboard using high voltage power processing equipment developed at Marshall Space Flight Center and Ni-Cd batteries are discussed. These test results are used to extrapolate to an efficient, reliable, high capacity EPS for near term low Earth orbit, high power applications. EPS efficiencies, figures of merit, and battery reliability with a battery protection and reconditioning circuit are presented.

Lanier, J. R., Jr.↗

Sensitivity of thermal inertia calculations to variations in environmental factors

The sensitivity of thermal inertia (TI) calculations to errors in the measurement or parameterization of a number of environmental factors is considered here. The factors include effects of radiative transfer in the atmosphere, surface albedo and emissivity, variations in surface turbulent heat flux density, cloud cover, vegetative cover, and topography. The error analysis is based upon data from the Heat Capacity Mapping Mission (HCMM) satellite for July 1978 at three separate test sites in the deserts of the western United States. Results show that typical errors in atmospheric radiative transfer, cloud cover, and vegetative cover can individually cause root-mean-square (RMS) errors of about 10 percent (with atmospheric effects sometimes as large as 30-40 percent) in HCMM-derived thermal inertia images of 20,000-200,000 pixels.

Kahle, A. B.↗

Parametric and cycle tests of a 40-AH bipolar nickel-hydrogen battery

The performance of a 12 V, 40 ampere-hour bipolar battery during various charge current, discharge current, temperature, and pressure operating conditions is investigated. The cell voltages, temperatures, ampere-hours, and watt-hours derived from the charge/discharge cycle tests are studied. Consideration is given to battery voltage and discharge capacity as a function of discharge current, the correlation between energy delivered on a discharge and battery temperature, battery voltage response to pulse discharges, and the voltage-temperature relationship. The data reveal that the bipolar Ni-H battery is applicable to high power systems.

Cataldo, R. L.↗

Performance characteristics of lithium primary cells after controlled storage

A program was initiated to investigate the effects of storage on the performance of lithium primary cells. Two types of liquid cathode cells were chosen to investigate these effects. The cell types included Li-SOCl2/BCX cells, Li-SO2 cells from two different manufacturers, and a small sample size of 8-year-old Li-SO2 cells. The following measurements are performed at each test interval: open circuit voltage, resistance and weight, microcalorimetry, ac impedance, capacity, and voltage delay. The authors examine the performance characteristics of these cells after one year of controlled storage at two temperatures (10 and 30 C). The Li-SO2 cells experienced little to no voltage and capacity degradation after one year storage. The Li-SOCl2/BCX cells exhibited significant voltage and capacity degradation after 30 C storage. Predischarging shortly prior to use appears to be an effective method of reducing the initial voltage drop. Studies are in progress to correlate ac impedance and microcalorimetry measurements with capacity losses and voltage delay.

Deligiannis, F.↗

Performance of low resistance microchannel plate stacks

Results are presented from an evaluation of three sets of low resistance microchannel plate (MCP) stacks; the tests encompassed gain, pulse-height distribution, background rate, event rate capacity as a function of illuminated area, and performance changes due to high temperature bakeout and high flux UV scrub. The MCPs are found to heat up, requiring from minutes to hours to reach stabilization. The event rate is strongly dependent on the size of the area being illuminated, with larger areas experiencing a gain drop onset at lower rates than smaller areas.

Siegmund, O. H. W.↗

A lunar/Martian anchor emplacement system

On the Moon or Mars, it is necessary to have an anchor, or a stable, fixed point able to support the forces necessary to rescue a stuck vehicle, act as a stake for a tent in a Martian gale, act as a fulcrum in the erection of general construction poles, or support tent-like regolith shields. The anchor emplacement system must be highly autonomous. It must supply the energy and stability for anchor deployment. The goal of the anchor emplacement system project is to design and build a prototype anchor and to design a conceptual anchor emplacement system. Various anchors were tested in a 1.3 cubic meter test bed containing decomposed granite. A simulated lunar soil was created by adjusting the moisture and compaction characteristics of the soil. We conducted tests on emplacement torque, amount of force the anchor could withstand before failure, anchor pull out force at various angles, and soil disturbances caused by placing the anchor. A single helix auger anchor performed best in this test bed based on energy to emplace, and the ultimate holding capacity. The anchor was optimized for ultimate holding capacity, minimum emplacement torque, and minimum soil disturbance in sandy soils yielding the following dimensions: helix diameter (4.45 cm), pitch (1.27 cm), blade thickness (0.15 cm), total length (35.56 cm), shaft diameter (0.78 cm), and a weight of 212.62 g. The experimental results showed that smaller diameter, single-helix augers held more force than larger diameter augers for a given depth. The emplacement system consists of a flywheel and a motor for power, sealed in a protective box supported by four legs. The flywheel system was chosen over a gear system based on its increased reliability in the lunar environment.

Clinton, Dustin↗