Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “calibrated”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

MAESTRO1 data set calibration: The JRC approach

Calibration is a fundamental task for analysis. Therefore, the Microwave Team of the JRC Ispra has put considerable effort investigating and checking the different calibration techniques, using the data collected during the MAESTRO1 campaign. We report on this activity. First, we give an overview of the algorithms used for phase and radiometric calibration. Then, we describe the software tools that were developed to support the calibration data processing. Finally, we present and discuss the results obtained from the calibration in the test sites of Freiburg and Flevoland.

Lavalle, C.↗

Calibration of a polarimetric imaging SAR

Calibration of polarimetric imaging Synthetic Aperture Radars (SAR's) using point calibration targets is discussed. The four-port network calibration technique is used to describe the radar error model. The polarimetric ambiguity function of the SAR is then found using a single point target, namely a trihedral corner reflector. Based on this, an estimate for the backscattering coefficient of the terrain is found by a deconvolution process. A radar image taken by the JPL Airborne SAR (AIRSAR) is used for verification of the deconvolution calibration method. The calibrated responses of point targets in the image are compared both with theory and the POLCAL technique. Also, response of a distributed target are compared using the deconvolution and POLCAL techniques.

Sarabandi, K.↗

SeaWiFS calibration and validation plan, volume 3

The Sea-viewing Wide Field-of-view Sensor (SeaWiFS) will be the first ocean-color satellite since the Nimbus-7 Coastal Zone Color Scanner (CZCS), which ceased operation in 1986. Unlike the CZCS, which was designed as a proof-of-concept experiment, SeaWiFS will provide routine global coverage every 2 days and is designed to provide estimates of photosynthetic concentrations of sufficient accuracy for use in quantitative studies of the ocean's primary productivity and biogeochemistry. A review of the CZCS mission is included that describes that data set's limitations and provides justification for a comprehensive SeaWiFS calibration and validation program. To accomplish the SeaWiFS scientific objectives, the sensor's calibration must be constantly monitored, and robust atmospheric corrections and bio-optical algorithms must be developed. The plan incorporates a multi-faceted approach to sensor calibration using a combination of vicarious (based on in situ observations) and onboard calibration techniques. Because of budget constraints and the limited availability of ship resources, the development of the operational algorithms (atmospheric and bio-optical) will rely heavily on collaborations with the Earth Observing System (EOS), the Moderate Resolution Imaging Spectrometer (MODIS) oceans team, and projects sponsored by other agencies, e.g., the U.S. Navy and the National Science Foundation (NSF). Other elements of the plan include the routine quality control of input ancillary data (e.g., surface wind, surface pressure, ozone concentration, etc.) used in the processing and verification of the level-0 (raw) data to level-1 (calibrated radiances), level-2 (derived products), and level-3 (gridded and averaged derived data) products.

Hooker, Stanford B.↗

Calibrated imaging radar polarimetry - Technique, examples, and applications

The authors developed a calibration procedure for imaging radar polarimeters and applied it to a set of images acquired by the NASA DC-8 multifrequency radar system. The technique requires the use of ground reflectors known cross-section for absolute calibration, that is, solution for sigma exp 0; however, the image data themselves can usually provide all information necessary for phase calibration and for antenna crosstalk correction. The accuracy of the approach, as measured by calculating the cross-section residuals of known targets in each calibrated scene, is on the order of +/- 1-2 dB at P- and C-band, but improves to +/- 0.5 dB at L-band. The authors present the results of applying this technique to radar scenes of lava flows of varying roughness, temperate and tropical rain forests, and ocean water surfaces. They also present several example applications which are feasible with calibrated data but which would be difficult to implement with uncalibrated data.

Zebker, Howard A.↗

Calibration of a polarimetric imaging SAR

Calibration of polarimetric imaging Synthetic Aperture Radars (SAR's) using point calibration targets is discussed. The four-port network calibration techniques is used to describe the radar error model. The polarimetric ambiguity function of the SAR is then found using a single point target, namely a trihedral corner reflector. Based on this, an estimate for the backscattering coefficient of the terrain is found by a deconvolution process. A radar image taken by the JPL Airborne SAR (AIRSAR) is used for verification of the deconvolution calibration method. The calibrated responses of point targets in the image are compared both with theory and the POLCAL technique. Also, response of a distributed target are compared using the deconvolution and POLCAL techniques.

Sarabandi, Kamal↗

Recent Goddard Space Flight Center (GSFC) experience with on-orbit calibration of attitude sensors

The results of on-orbit calibration for several satellites by the flight Dynamics Facility (FDF) at GSFC are reviewed. The examples discussed include attitude calibrations for sensors, including fixed-head star trackers, fine sun sensors, three-axis magnetometers, and inertial reference units taken from recent experience with the Compton Gamma Ray observatory, the Upper Atmosphere Research Satellite, and the Extreme Ultraviolet Explorer calibration. The methods used and the results of calibration are discussed, as are the improvements attained from in-flight calibration.

Davis, W.↗

Pinhole Calibrator For Particle-Sizing Instrument

Rotating-pinhole calibrator designed for use in calibrating and testing optical instrument measuring sizes of cloud droplets, dust particles, and other small particles suspended in flowing air. Easily attachable to particle-size-measuring instrument and suitable for both quick verification of calibration in field and detailed calibration studies in laboratory. Calibrator used to determine such operating parameters of instrument as optical collection angles, depth of field, profile of laser beam used to measure particles, and response to trajectory of particle. Also used to align instrument. Pinhole reused any number of times without risk of variation in diffraction pattern. Furthermore, size of pinhole chosen precisely and at will.

Hovenac, Edward↗

Automatically calibrating admittances in KATE's autonomous launch operations model

This report documents a 1000-line Symbolics LISP program that automatically calibrates all 15 fluid admittances in KATE's Autonomous Launch Operations (ALO) model. (KATE is Kennedy Space Center's Knowledge-based Autonomous Test Engineer, a diagnosis and repair expert system created for use on the Space Shuttle's various fluid flow systems.) As a new KATE application, the calibrator described here breaks new ground for KSC's Artificial Intelligence Lab by allowing KATE to both control and measure the hardware she supervises. By automating a formerly manual process, the calibrator: (1) saves the ALO model builder untold amounts of labor; (2) enables quick repairs after workmen accidently adjust ALO's hand valves; and (3) frees the modeler to pursue new KATE applications that previously were too complicated. Also reported are suggestions for enhancing the program: (1) to calibrate ALO's TV cameras, pumps, and sensor tolerances; and (2) to calibrate devices in other KATE models, such as the shuttle's LOX and Environment Control System (ECS).

Morgan, Steve↗

Absolute calibration of an ultraviolet spectrometer using a stabilized laser and a cryogenic cavity radiometer

We carry out the calibration of an ultraviolet spectrometer by using a cryogenic electrical-substitution radiometer and intensity-stabilized laser sources. A comparison of the error budgets for the laser-based calibration described here and for a calibration using a type-FEL tungsten spectral-irradiance standard indicates that this technique could provide an improvement of a factor of about three in the uncertainty of the spectrometer calibration, resulting in an absolute accuracy (standard deviation of three) of about 1 percent at 257 nm. The technique described here might significantly improve the accuracy of calibrations on NASA ozone-monitoring and solar ultraviolet-monitoring spectrophotometers when used to complement present procedures that employ lamps and the SURF II synchrotron ultraviolet radiation facility at the National Institute of Standards and Technology.

Jauniskis, L.↗

An assessment of the Nimbus-7/CZCS calibration for May 1986 using satellite and in situ data from the Arabian Sea

A hydrographic survey of the central Arabian Sea was conducted in May 1986 and stations were correlated with Nimbus-7/Coastal Zone Color Scanner (CZCS) overpasses. As calibration of the CZCS degraded severely during its lifetime, pigment concentrations from samples at four sites in the Arabian Sea were used to refine the calibration of the CZCS. This vicarious calibration technique provided a final estimate of the sensor's sensitivity loss for sensor Gain 2. Calibration using normalized water-leaving radiance for the 520 nm and 550 nm bands showed considerable final sensor degradation. Future missions must incorporate calibration validation programs in order to maintain derived product accuracy requirements. Profiles of pigment concentration, salinity, temperature, and light attenuation are used to describe the bio-optical characteristics of the Arabian Sea during the intermonsoon period.

Hay, Bernward J.↗

Evaluation of the Earth Radiation Budget Experiment (ERBE) shortwave channel's stability using in-flight calibration sources

The Earth Radiation Budget Experiment (ERBE) radiometers were designed to make absolute measurements of the incoming solar, earth-reflected solar, and earth-emitted fluxes for investigations of the earth's climate system. Thermistor bolometers were the sensors used for the ERBE scanning radiometric package. Each thermistor bolometer package consisted of three narrow field of view broadband radiometric channels measuring shortwave, longwave, and total (0.2 micron to 50 microns) radiation. The in-flight calibration facilities include Mirror Attenuator Mosaics, shortwave internal calibration source, and internal blackbody sources to monitor the long-term responsivity of the radiometers. This paper describes the in-flight calibration facilities, the calibration data reduction techniques, and the results from the in-flight shortwave channel calibrations. The results indicate that the ERBE shortwave detectors were stable to within +/- 1 percent for up to five years of flight operation.

Gibson, Michael A.↗

In-flight shortwave calibrations of the active cavity radiometers using tungsten lamps

The Earth Radiation Budget Experiment (ERBE) active cavity radiometers are used to measure the incoming solar, reflected shortwave solar, and emitted longwave radiations from the Earth and atmosphere. The radiometers are located on the NASA's Earth Radiation Budget Satellite (ERBS) and the NOAA-9 and NOAA-10 spacecraft platforms. Two of the radiometers, one wide field of view (WFOV) and one medium field of view (MFOV), measure the total radiation in the spectral region of 0.2 to 50 microns and the other two radiometers (WFOV and MFOV) measure the shortwave radiation in the spectral region of 0.2 to 5.0 microns. For the in-flight calibrations, tungsten lamp and the sun are used as calibration sources for shortwave radiometers. Descriptions of the tungsten lamp and solar calibration procedures and mechanisms are presented. The tungsten lamp calibration measurements are compared with the measurements of solar calibration for ERBS and NOAA-9 instruments.

Thomas, Susan↗

Calibration of the AVHRR visible and near-IR bands by atmospheric scattering, ocean glint and desert reflection

A method for calibrating satellite sensors (such as the AVHRR visible and NIR bands) is proposed by which the sensors are calibrated using well-known physical characteristics of the atmosphere, ocean, and deserts, as well as the digital satellite imagery. The approach, independent of ground support, used the following three phenomena: molecular scattering over the ocean for absolute visible band calibration; ocean glint, to transfer the calibration from the visible band to the NIR band; and desert reflectance to monitor, independently, the stability of the visible and NIR bands. The method was applied to NOAA-7, -9, and -11 sensors. The results of the ocean and the desert calibration methods were found to differ in the brightness range and the spectral response of the radiance source (molecular scattering over the ocean versus the desert reflectance).

Kaufman, Y. J.↗

Using calibrated SAR data

A number of approaches for calibrating SAR imaging data including data from multipolarization and multifrequency systems developed at the Jet Propulsion Laboratory are discussed. It is shown how calibrated SAR data can be used to improve the understanding of the physical properties of the earth's surface layer and how calibration uncertainties and system noise should be handled by the SAR data user. Examples of calibrated SAR data from the NASA/JPL DC-8 SAR are used to demonstrate use of calibrated data to monitor temporal change and to improve the classification of land cover type.

Freeman, Anthony↗

Development and calibration of UV/VUV radiometric sources

A program exists at NIST to calibrate radiometric sources for the spectral range from 118-350 nm. These include deuterium lamps, hollow-cathode lamps, RF-excited dimer lamps, and wall-stabilized argon arcs. Sources have been calibrated for and used by researchers in solar physics, astrophysics, atmospheric physics (ozone measurements), magnetically controlled fusion, and photobiology. The argon arcs were developed in our laboratory, and provide intense sources of both radiance and irradiance. Calibrations are performed relative to two primary sources, a wall-stabilized hydrogen arc and a 12,000 K black-body line arc, both developed in our laboratory. Also we recently have begun periodic calibrations on the NIST storage ring, SURF II, to insure consistency between our respective radiometric bases. Various sources have been calibrated for space' applications, including several which are flyable. Also, some development and testing of radiometers for semiconductor lithography were recently carried out with an intense argon arc source.

Bridges, J. M.↗

Relative phase calibration of the NASA/DC-8 three-frequency polarimetric SAR system

Relative phase calibration of radar polarimetry data may be achieved by utilizing the phase information of the receiver calibration tone and knowledge of the antenna path differences among channels measured upon installation of the radar polarimeter. This calibration method does not require any assumptions on the scattering behavior of the scene. This method of phase calibration may be verified by examining the polarization signatures of calibration instruments such as the trihedral corner reflectors.

Lou, Yunling↗

Overview of the 1989 Wind Tunnel Calibration Workshop

An overview of the 1989 Wind Tunnel Calibration Workshop held at NASA LaRC in Hampton, VA on 19-20 Apr. 1989 is presented. The purpose of the Workshop was to explore wind tunnel calibration requirements as they relate to test quality and data accuracy, with the ultimate goal of developing wind tunnel calibration requirements for the major NASA wind tunnels at ARC, LaRC, and LeRC. The two sessions addressed the following topics: (1) what constitutes a properly calibrated wind tunnel; and (2) the status of calibration of NASA's major wind tunnels. The most significant contributions to the stated goals are highlighted, and the consensus of the Workshop's conclusions and recommendations regarding formulation and implementation of that goal are presented.

Henderson, Arthur, Jr.↗

In-flight scale/distortion calibration of the Hubble Space Telescope fixed-head star trackers

This paper describes an in-flight scale and distortion calibration procedure that has been developed for the Ball Aerospace Systems Division Fixed-Head Star Trackers (FHST's) used on the Hubble Space Telescope (HST). The FHST is a magnetically focused and deflected imaging sensor that is designed to track stars as faint as m(sub v) = 5.7 over an 8 degree by 8 degree field of view. Raw FHST position measurements are accurate to approximately 200 arcseconds, but this can be improved to 10-15 arcseconds by processing the raw measurements through calibration polynomials that correct for flat field, temperature intensity, and magnetic field effects. The coefficients for these polynomials were initially determined using ground test data. On HST the use of three FHST's is an integral part of the preliminary attitude update procedures required before the acquisition of guide stars for science observations. To this end, FHST-based attitude determination having single-axis errors no worse than 22 arcseconds (1 sigma) is required. In early 1991 it became evident that one of the HST FHST's was experiencing a significant change in its optical scale. By mid-1993 the size of this error had grown to a point that, if not corrected, it would correspond to a maximum position error on the order of 100 arcseconds. Subsequent investigations demonstrated that substantial, uncompensated cubic distortion effects had also developed, the maximum contribution to position errors from the cubic terms being on the order of 30 arcseconds. To ensure accurate FHST-based attitude updates, procedures have been developed to redetermine the FHST scale and distortion calibration coefficients based on in-flight data gathered during normal HST operations. These scale and distortion calibrations have proven very effective operationally, and procedures are in place to monitor FHST calibration changes on a continuing basis.

Mccutcheon, R.↗