Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “building cooling system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

710 records · Page 40

Human Thermal Assessment of Traverse and Geology Task Iterations During Simulated Lunar Extravehicular Activity

Spacewalks or extravehicular activities (EVA) in microgravity are mentally and physically demanding. Current microgravity EVAs are predominantly focused on upper body tasks on engineered surfaces; however, the introduction of gravity means that crew members during future lunar EVAs will be required to perform tasks that generate full body workloads such as navigating natural lunar terrain while conducting geological sampling. To date, only 12 people have walked on the surface of the Moon resulting in limited knowledge of suited thermal regulation under lunar-relevant physical workloads. To address this gap, a study is underway to focus on spacesuit operations with simulated lunar EVA workloads. This study presents methodology for collecting standard thermal measures during suit testing. In this pilot study, two suited subjects underwent simulated lunar EVAs using the NASA Active Response Gravity Offload System (ARGOS) to simulate the effects of partial gravity. Each lunar EVA, lasting three to five hours, included various metabolically demanding EVA tasks. Subjects donned the NASA Mark III (MK III) space suit and were offloaded to 1/6th G (lunar gravity). A subset task circuit from one of these simulations replicated an EVA traverse to a lunar crater, taking a geological sample, and returning to base. The suited subject walked one 1500 m (0% grade) and three 500 m traverses at three different grades (10, 20, 30%). Between each traverse, subjects performed geology sampling tasks (0 and 10% grade). Thermal measurements included core and skin temperature, liquid cooling garment (LCG) inlet and outlet temperature, and spacesuit gas inlet and outlet temperature and humidity. Compared to baseline core temperature (S1 = 37.07±0.32 °C, S2 = 37.27±0.01 °C) and mean skin temperature (S1 = 32.38±0.34 °C, S2 = 33.62±0.03 °C), after a 1500 m traverse, each suited subject showed an increased core temperature (S1 = 37.23±0.12 °C, S2 = 37.41±0.11°C) and decreased mean skin temperature (S1 = 32.16±0.17 °C, S2 = 31.53±1.15 °C) at a delta LCG temperature (S1 = 1.86±0.24 °C, S2 = 2.20±0.76 °C) and delta suit humidity (S1 = 9.66±1.49 %, S2 = 11.50±1.58 %). Core temperature continued to increase from compounding traverse and geology tasks (S1 = 38.04±0.03 °C, S2 = 38.1±0.02 °C) accompanied by an increase in delta LCG temperature (S1 = 2.24±0.13 °C, S2 = 2.67±0.12 °C) and delta suit humidity (S1 = 28±2.42 %, S2 = 31±2.13 %). Conversely, as the circuit progressed, mean skin temperature continued to decrease due to sustained LCG heat rejection (S1 = 30.08±0.15 °C, S2 = 30.28±0.07 °C). During the simulated EVA circuit core temperature increased to elevated values and remained elevated as heat was retained while mean skin temperature decreased due to peripheral heat offloaded to the LCG. The thermal measures collected during this study provided critical heat loading dynamics during lunar EVA tasks. Including core and skin temperatures along with suited thermal measures provides a standard data collection scheme for human thermal metrics during EVA task management. Data collected in this configuration can be used to build future lunar EVA task circuits and human thermal predictions.

Bradley Hoffmann↗

Unified Modeling Architecture for Load Management in Extreme Heat: The New York City Case

Integration of renewable resources to meet growing energy demand is becoming a global priority under decarbonization mandates. This study contributes to ongoing efforts on this key subject by assessing the feasibility of using coastal-urban renewable energy resources, namely, offshore wind and rooftop photovoltaic systems, to meet electricity demand of New York City during the intense recent heat wave period of June 2025. A unified modeling framework, based on the urbanized weather research and forecasting model, is used to simulate climate, renewable resources, and energy demand variables. Findings show significant energy load mismatch of approximately 1150 GWh over the month, between the demand and the combined renewable generation outcome. Three storage integration scenarios are analyzed to mitigate the deficits, reducing said deficits by a minimum of approximately 9% over the duration of the month. This study provides a transferable modeling framework tool for evaluating renewable integration in dense urban environments that can be used by grid operators to support grid resilience during extreme heat events.

54 ENVIRONMENTAL SCIENCES↗

Experimental Evaluation of Refrigerant Leak Characteristics for Different HVAC&R Equipment Types–Phase 2

The US Department of Energy (DOE) Building Technology Office (BTO) and the Air-conditioning, Heating & Refrigeration Technology Institute (AHRTI) collaborated to sponsor an experimental study of refrigerant leak characteristics at Oak Ridge National Laboratory (ORNL); AHRTI project 9012. The project has been conducted in two phases with objectives to conduct refrigerant leak tests on several heating, ventilating, air-conditioning and refrigeration (HVAC&R) systems under operating conditions representative of actual applications to document the pressure decay rate and the mass flow rate of leaked refrigerant as a function of time. Phase 1 of the project ran from late 2017 to late 2018 with refrigerant leaks imposed on five systems and the collection of data to meet the project objectives. Systems chosen covered three air-conditioning (AC) applications (packaged terminal AC or PTAC, 3-ton residential split system AC, and 5-ton packaged rooftop AC) and two refrigeration applications (split system unit cooler, and standalone display case). AHRTI members donated the test systems used for the project. The systems were tested at two different leak rates (catastrophic high rate simulating full line break and a lower flow rate), two leak locations (high-pressure side and low-pressure side), and two operating conditions (compressor ON or OFF). Phase 1 results were summarized in a project report by Baxter, et al. (2019)1. The leak rates imposed in Phase 1 led to much more rapid charge releases than the more typical much slower rates seen in practice that would take days, weeks, or months to empty a system of its entire charge. For Phase 2, the project sponsors asked that the “higher” leak rate target a total charge release time of about 4 min. This was intended to represent a “reasonable” worst case release scenario to match the refrigerant leak rate assumption used in the International Electrotechnical Commission (IEC) standard IEC 60335-2-40 (2016 version [IEC 2016]. A charge release time of about 20–40 min (leak release rate 5 to 10 times lower than higher rate) was targeted for the “lower” leak rate. This report provides a summary of the Phase 2 effort. Two additional HVAC systems were selected for testing in this phase. First was a multi-split air-conditioning (MS-AC) system with one outdoor section and two indoor units and a nameplate refrigerant charge of 1.75 kg (3.86 lb.) of R-410A. The MS-AC was tested in cooling only or AC operation. Second was a split system heat pump coupled to two different representative supply duct systems (HP-duct) and a nameplate charge of 3.83 kg (8.44 lb.) of R-410A. This system was tested in both space heating and AC modes. As in Phase 1 of the project, all tests were conducted using R-410A.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Holistic energy analysis method for thermal management architectures of data centers

Modern high-performance computing (HPC) data centers (DCs), particularly those supporting energy-intensive artificial intelligence (AI) workloads, face escalating thermal management challenges that degrade performance through thermal throttling and drive up cooling power consumption and operational costs. To address this challenge, many have developed a wide variety of thermal management solutions (single-phase, two-phase, direct, indirect, hybrid, and more) which attempt to cool HPC DCs effectively while attempting to minimize overall system power consumption. However, the analysis of these solutions and methods to effectively compare one with another is lacking. Overall power usage effectiveness (PUE) and total-power usage effectiveness (TUE) provide a metric to quantify power consumption but fail to identify components in the system which require further optimization. To address this, we propose a holistic analytical framework – the waterfall diagram (WFD) – which leverages a waterfall chart methodology, offering a comprehensive visualization of both the thermal management system loop and heat flow pathways from individual server components to the outdoor ambient. Use of the WFD enables graphical estimations of power efficiency and cooling performance across each component of a DC cooling system and complements Sankey-style energy flow visualizations by additionally resolving stage-wise temperature changes and incremental TUE contributions. The framework is used in conjunction with simulation-based approaches, to conduct a detailed pressure drop and flow distribution analysis aimed at identifying the optimal coolant distribution architecture for a single-phase direct-to-chip water-cooled DC, which serves as the baseline for subsequent WFD analysis. Among the evaluated architectures, the 3 U modular coolant distribution architecture is found to demonstrate the best performance, considering minimal pressure drop and uniform flow distribution. In addition, TUE is calculated for each cooling loop component based on its associated pressure drop and corresponding pumping power, which are integrated into the WFD. This correlation between TUE and local temperature offers immediate insight into the power efficiency and thermal performance contributions of individual components, facilitating further development and optimization. Examples of WFD applications are presented under varying thermal loads and ambient conditions, demonstrating reasonable cooling strategies. Notably, the 3 U modular architecture maintains a consistent chip case temperature of 85°C, achieving a TUE of 1.016 at ambient temperature of 47°C, and a TUE of 1.026 at ambient temperature of 52°C. The WFD methodology provides an efficient, holistic, and streamlined framework for DC thermal management architecture assessment and enables design optimization which is important for addressing the thermal-fluidic energy challenges of current and next-generation DCs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Maintainable Fusion Pilot Plant

The US fusion community has coalesced around the goal of building an FPP as described by the National Academies of Science, Engineering, and Medicine (NASEM). In addition to demonstrating the viability of the technologies necessary to operate such a plant, including demonstration of net energy and electricity production, NASEM found that a “fusion pilot plant will need to demonstrate the ability to efficiently perform remote maintenance and replacement in support of the design of a power plant, taking into account details of the consequences of the fusion environment, such as material activation and tritium retention in components.” Current designs of fusion demonstration reactors do usually foresee a regular exchange of their first wall modules, including the tritium breeding blankets. In the European Power Plant Conceptual Studies, it is assumed that a fusion reactor will need to change its divertor every 2 years and its first wall blanket module every 5 to 6 years to reach acceptable availability. Underlying this capability are remote-handling technologies to keep the outage for the exchange of these components short. There are many uncertainties in the remote-handling schemes, and most schemes are at a preconceptual level at best. In addition, the exchange of these components would either produce an enormous rad-waste stream or would require an enormous refurbishment activity with huge cost-prohibitive hot-cells. Past Fusion Nuclear Science Facility (FNSF) preconceptual studies have led to hot cell dimensions of an unbelievable size, likely costing tens of billions of dollars. Already at The Way (previously International Thermonuclear Experimental Reactor, ITER), hot-cells have become cost-prohibitive, demanding redesigns of the ITER first wall to reduce the toxic rad-waste/inventory. In this in-situ PFC repair project, a concept for a long-life, maintainable first wall module concept is developed and tested. This first wall concept relies on innovative remote handling to repair the first wall modules in-situ, avoiding costly refurbishments outside of the tokamak vessel. This approach was highlighted in the Fusion Energy Sciences Advisory Committee (FESAC) report on Transformative Enabling Capabilities for Efficient Advance Toward Fusion Energy. In general, the damage of the first wall armor is due to particle and radiation exposures. Load conditions vary from one fusion reactor design to another. In tokamaks, first wall Plasma Facing Components (PFCs) are exposed to far-Scrape-Off-Layer plasma fluxes, electromagnetic radiation, energetic CX neutrals, and potentially runaway electron beams. Protecting the first wall to the worst-case load conditions would require the design of a very thick first wall armor. Transient heat and particle fluxes due to disruptions or edge localized modes can lead to excessive heat loads resulting potentially in melting PFCs down to the cooling channel. Catastrophic events like these need to be avoided by appropriate disruption mitigation systems. However, failure of these systems will still put a first wall at an unacceptable risk. Hence, a first wall design needs to accommodate the occasional transient heat loads by introducing sacrificial limiters, which will absorb these transients.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modernization of Technical Requirements for Licensing of Advanced Non-Light Water Reactors: Risk-Informed and Performance-Based Evaluation of Defense-in-Depth Adequacy

This document supports the work contained in Nuclear Energy Institute (NEI) 18-04 “Risk-Informed Performance-Based Technology Inclusive Guidance for Advanced Reactor Licensing Basis Development” Revision 0. NEI 18-04 presents a modern, technology-inclusive, risk-informed, and performance-based (TI-RIPB) process for selection of Licensing Basis Events (LBEs); safety classification of structures, systems, and components (SSCs) and associated risk-informed special treatments; and determination of defense-in-depth (DID) adequacy for non-LWRs. The NEI guidance document provides one acceptable means for addressing the aforementioned topics as part of demonstrating a specific design provides reasonable assurance of adequate radiological protection. This report provides the framework and associated methodology guidelines and discussion for establishing, then evaluating, confirming, and documenting the adequacy of defense-in-depth (DID) for advanced non-light-water reactor technologies. It was developed as part of the Licensing Modernization Project led by Southern Company and cost-shared by the United States Department of Energy and has benefited from considerable NRC formal reviews and public workshops. The methodology converts the DID philosophy into a structured process that is implementable, embraces existing United States and international definitions and philosophies of DID that set the foundation for the process. It builds on the DID framework developed in the Department of Energy Next Generation Nuclear Plant Project and earlier works on this subject. The approach to establishing DID adequacy involves the incorporation of DID attributes into the plant capabilities and programmatic elements of DID. The integrated evaluation of DID adequacy includes both quantitative elements to incorporate risk-informed and performance-based (RIPB) considerations and qualitative elements that address uncertainties and limitations in the quantitative models and supporting data. Demonstration of DID adequacy ensures that there are multiple layers of defense for risk-significant challenges to the design and that the plant capabilities and programs that support each layer are provided in a manner that minimizes dependencies among these layers. The focus of this report is assurance of DID adequacy with respect to protection of the public from radiological exposures resulting from accidental releases of radioactive material. While other hazards are not specifically addressed, this methodology is expected to be beneficial for determining DID adequacy for them as well. Risk-informed evaluation of DID considers the integrated performance of all plant SSCs and associated programs to manage daily operational activities, transients, and accidents, including the evaluation of strategies for accident prevention and mitigation. The RIPB LBE scenario methodology used in this evaluation defines the challenges to the plant safety features included in the plant design basis and beyond, and the scope of all deterministic and probabilistic safety evaluations. By examining event sequences across the whole spectrum of LBEs, a systematic assessment of DID can be accomplished.

42 ENGINEERING↗

Large Solar-Rejection Filter

NASA utilized Image Intensified Video Cameras for ATV data acquisition from a jet flying at 12.8 km. Afterwards the video was digitized and then analyzed with a modified commercial software package, Image Systems Trackeye. Astrometric results were limited by saturation, plate scale, and imposed linear plate solution based on field reference stars. Time-dependent fragment angular trajectories, velocities, accelerations, and luminosities were derived in each video segment. It was evident that individual fragments behave differently. Photometric accuracy was insufficient to confidently assess correlations between luminosity and fragment spatial behavior (velocity, deceleration). Use of high resolution digital video cameras in future should remedy this shortcoming. A scenically accurate description of matter interpreted as a substance made up of corpuscular constituents was established during the course of the 19th century. In this description, atoms--the building blocks of the matter--form molecules. The properties of the molecules were described by chemistry or thermodynamics depending on what characteristics of the matter were investigated. In both theories, the molecules can dissociate to atoms when the kinetic energies of the atoms exceed the strength of the chemical bonds. The number of atoms is always preserved in a closed system. This is not true, however, when the matter takes up much higher energies at relativistic scales. New particles can be produced at the expense of the kinetic energy. The number of particles is no longer preserved. There are other conserved quantities, however, these quantities, the charge, baryon number, lepton number, are associated with particles that are considered elementary today. The properties and behavior of these elementary particles is the subject of Particle Physics or High Energy Physics. Practice Page: A crewmember touching a positively charged surface was thought to be galvanically isolated from the vehicle ground analogous to a bird on a high voltage power wire. Recent analysis confirms that positive floating potentials, ionospheric currents to the EVA suit, can be hazardous. The analysis is wrong in that the ionospheric plasma itself can close the circuit. Parametric analysis of very low voltage exposures (2 to 15 volts) could cause pain and/or involuntary muscle tetani or spinal cord shock. NASA worked with the Naval Health Research Center Detachment Directed Energy Bioeffects Laboratory to examine the affects electrical hazards could have on extravehicular activity using two models. The results of the two computational models were combined to predict areas of the body in which neurons of different diameters would be excited. They predicted that physiologically active current could be conducted across the crew member causing catastrophic hazards. Future work to analyze additional current paths was proposed. The FUSE spectrum of BB Dor, observed in a high state, is modeled with an accretion disk with a very low inclination (possibly lower than 10 degrees). Assuming an average WD mass of 0.8 solar mass leads to a distance of the order of approximately 650pc, consistent with the extremely low galactic reddening in its direction, and a mass accretion rate of 10 (exp -9) solar mass a year. The spectrum presents some broad and deep silicon and sulfur absorption lines, indicating that these elements are over-abundant: silicon is 3 times solar, and sulfur is 20 times solar. The FUSE spectrum of BB Dor, observed in a high state, is modeled with an accretion disk with a very low inclination (possibly lower than 10 degrees). Assuming an average WD mass of 0.8 solar mass leads to a distance of the order of approximately 650pc, consistent with the extremely low galactic reddening in its direction, and a mass accretion rate of 10 (exp -9) solar mass a year. The spectrum presents some broad and deep silicon and sulfur absorption lines, indicating that these elements are over-abundant: silicon is times solar, and sulfur is 20 times solar. From its previously observed optical emission lines, P831-57 (WD 0334 6400 or Ret 1 in A Catalog and Atlas of Cataclysmic Variables: Living Edition) has been suspected to contain an accretion disk associated with a companion star in orbit around a subdwarf star with a temperature T is greater than 21,000K. P831-57 has therefore been classified as a nova-like. However, our present observations show it to be a DA + dMe binary. The analysis of its Far Ultraviolet Spectroscopic Explorer (FUSE) spectrum (continuum and lines) reveal an average mass white dwarf (Log(g) approximately equals 7.8 plus or minus 0.1)with a temperature T approximately equals 37,000 plus or minus 500K, an extremely low projected rotational velocity, and a distance of about 115 plus or minus 5pc. The photosphere contains C, N, Si, and S (at about 1% of solar abundances). The dMe star is seen as a flux excess in near-infrared photometry and appears to show occasional flaring of about one magnitude as seen in the Harvard plates. There is no evidence of periodic variability in the spectroscopic or photometric data. We find no evidence of a an accretion disk, instead we find evidence of wind accretion as the stellar carbon abundance (N(C)/N(H) = 2.5 x 10 (exp -6) is about ten times larger than predicted by radiative levitation for such a gravity and temperature. The power needs and solutions for the space exploration and lunar mobility program are discussed. Long term missions in space and on the lunar surface require high energy batteries. Rechargeable batteries for mobility systems and portable utility pallet are needed for successful exploration missions. Nanomaterial usage increases the energy density of the cells apart from increasing the power density. The symptoms and threats from acute mountain sickness (AMS) are discussed. The underlying assumptions concerning spacecraft atmosphere mean there is a potential risk to astronauts. The baseline worst case scenario is about 25% based on direct ascent to 8.0 psia with 32% O2. The practical mitigation approach is a staged depressurization scheme. Due to the uncertainty about potential AMS risk the flight surgeon should prepare, focused research should proceed, and current analytical efforts should continue. This slide presentation reviews the threat astronauts face from acute mountain sickness (AMS). The incidence of AMS is highly variable and the risk to astronauts is unclear. However, the potential risk is higher than current EAAs suggest and precautions should be implemented. Due to the uncertain nature of the risk flight surgeons should prepare, and focused research should proceed. Quasiparticle tunneling can be understood at low temperatures using a non-equilibrium kinetic theory. Low-temperature tunneling can be suppressed using existing techniques: island-lead gap engineering, lead cooling with SIN junctions, and quasiparticle traps. The slide presentation reviews the science goals and mission planning for the proposed Jupiter System Observer (JSO). The spacecraft would accommodate 9 instruments making the instrument payload more capable than any previously flown to Jupiter. The would-be mission includes study programs for Jupiter's satellites, interior, magnetosphere and atmosphere. The power needs and solutions for the space exploration and lunar mobility program are discussed. Long term missions in space and on the lunar surface require high energy batteries. Rechargeable batteries for mobility systems and portable utility pallet are needed for successful exploration missions. Nanomaterial usage increases the energy density of the cells apart from increasing the power density. This slide presentation reviews the power requirements for the space exploration and the lunar surface mobility programs. It includes information about the specifications for high energy batteries and the power requirements for lunar rovers,

Roberts, William↗

Constraining gas motion and non-thermal pressure beyond the core of the Abell 2029 galaxy cluster with XRISM

We report on a detailed spectroscopic study of the gas dynamics and hydrostatic mass bias of the galaxy cluster Abell 2029, utilizing high-resolution observations from XRISM Resolve. Abell 2029, known for its cool core and relaxed X-ray morphology, provides an excellent opportunity to investigate the influence of gas motions beyond the central region. Expanding upon prior studies that revealed low turbulence and bulk motions within the core, our analysis covers regions out to the scale radius $R_{2500}$ (670 kpc) based on three radial pointings extending from the cluster center toward the northern side. We obtain accurate measurements of bulk and turbulent velocities along the line of sight. The results indicate that non-thermal pressure accounts for no more than 2% of the total pressure at all radii, with a gradual decrease outward. The observed radial trend differs from many numerical simulations, which often predict an increase in non-thermal pressure fraction at larger radii. These findings suggest that deviations from hydrostatic equilibrium are small, leading to a hydrostatic mass bias of around 2% across the observed area.

X-rays: galaxies: clusters↗