Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “beam diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Unabsorbed light beamlets for diagnosing cross-beam energy transfer

Here, a new diagnostic has been fielded on OMEGA to diagnose cross-beam energy transfer (CBET) during direct-drive implosions. Unabsorbed light from each OMEGA laser beam is imaged as a distinct “spot” onto a gated optical imager. Each spot is in essence the end point of a beamlet of light that originates from different regions of each beam profile and follows a path determined by refraction. The intensity of light in the beamlet varies along its path as a result of absorption and CBET with other beamlets. This diagnostic allows the investigation of the effects of CBET on laser energy from specific locations of the beam profile. The diagnostic records images in two 200-ps time windows and includes a Wollaston prism to split each beamlet into two orthogonal polarizations recorded on separate images, allowing the absolute polarization of each beamlet to be determined. This diagnostic has provided the first evidence of polarization rotation caused by CBET during direct-drive implosions.

47 OTHER INSTRUMENTATION↗

Feedback Requirements for SASE-FELs

The operation of a Self Amplified Spontaneous Emission (SASE) Free Electron Lasers (FEL) at soft and hard X-ray wavelengths driven by a high brightness electron beam imposes strong requirements on the stability of the accelerator and feedback systems are necessary to both guarantee saturation of the SASE process as well as a stable photon beam for user experiments. Diagnostics for the relevant transverse and longitudinal beam parameters are presented and various examples of feedback systems for bunches with low repetition rate as well as systems for intra bunch train feedbacks are discussed.

43 PARTICLE ACCELERATORS↗

Minimizing Errant Beam at the Spallation Neutron Source

Over the years SNS has been optimizing the amount of errant beam pulses in the accelerator. The errant beam pulses can damage the superconducting cavities and thus lower the uptime of the accelerator. This talk will present the effort that has been made to lower the amount of errant beam pulses with new diagnostics, analysis of processes that cause errant beam, and the resulting lessons learned.

Peters, Charles C.↗

Space Charge Effects in Low Energy Magnetized Electron Beams

Magnetized electron cooling of the ion beam is one of the major approaches towards obtaining the required high luminosity in the proposed Electron-Ion Collider (EIC). To increase the cooling efficiency, a bunched electron beam with a high bunch charge and high repetition rate is required. However, these features can combine to enhance the collective interactions, such as the space charge effect. A magnetized electron beam was successfully generated at the Thomas Jefferson National Accelerator Facility (JLab) using a compact, 300 kV DC high voltage photo-gun with an inverted insulator geometry and bi-alkali antimonide photocathode. The beam magnetization was characterized using a modest diagnostic beamline to measure beam sizes, rotation angles, and normalized transverse emittance as a function of magnetic field at the photocathode, laser spot size, and gun high-voltage. Simultaneously, simulations were performed using the A Space Charge Tracking Algorithm (ASTRA) and General Particle Tracer (GPT) programs. Further, sustained high average current magnetized beam up to 28 mA was demonstrated, and the photocathode lifetime for different magnetized electron beam currents was investigated. In the second part of the project, the space charge effect in low-energy magnetized electron beams was studied and compared with GPT simulations. The high bunch charge studies showed evidence of space charge current limitations starting at 0.3 nC and limited the maximum delivered bunch charge to 0.7 nC. To reach the high bunch charge goal of a few nC, the existing DC photo-gun design was modified using CST Studio Suite’s electromagnetic field solver, and a way to cancel the beam deflection exerted by the non-symmetric nature of the inverted insulator photo-gun geometry was discovered. This thesis presents a detailed description of the generation, characterization, and simulation of high current, high bunch charge magnetized electron beams at JLab, as well as the modified photo-gun design. Together with measurements and simulations, the purpose of this thesis is to provide a solid background on the theoretical aspects and the experimental challenges associated with magnetized electron beams for accelerator applications.

Wijethunga, W M Sajini↗

PERFORMING DIAGNOSTICS ON THE SPALLATION NEUTRON SOURCE VISION BEAM LINE TO ELIMINATE HIGH VIBRATION LEVELS AND PROVIDE A SUSTAINABLE OPERATION

The Spallation Neutron Source (SNS) at the Oak Ridge National Laboratory (ORNL) provides variable energy neutrons for a variety of experiments. The neutrons proceed down beam lines to the experiment hall, which houses a variety of experiments and test articles. Each beam line has one or more neutron choppers which filter the neutron beam based on the neutron energy by using a rotating neutron absorbing material passing through the neutron beam. Excessive vibration of the Vision beam line, believed to be caused by the T0 chopper, prevented the Vision beam line from operating at full capacity. This problem had been addressed several times by rebalancing/reworking the T0 beam chopper but the problem stubbornly persisted. To determine the cause of the high vibration, dynamic testing was performed. Twenty-seven accelerometer and motor current channels of data were collected during drive up, drive down, coast down, and steady-state conditions; resonance testing and motor current signature analysis were also performed. The data was analyzed for traditional mechanical/machinery issues such as misalignment and imbalance using time series analysis, frequency domain analysis, and operating deflection shape analysis. The analysis showed that the chopper base plate was experiencing an amplified response to the excitation provided by the T0 beam chopper. The amplified response was diagnosed to be caused by higher than expected base plate flexibility, possibly due to improper grouting or loose floor anchors. Based on this diagnosis, a decision was made to dismantle the beam line chopper and remount the base plate. Neutron activation of the beam line components make modifications to the beam line especially expensive and time consuming due to the radiation handling requirements, so this decision had significant financial and schedule implications. It was found that the base plate was indeed loose because of improper grouting during its initial installation. The base plate was modified by splitting it into multiple sections, isolating the T0 chopper from the rest of the beam line, and each section was then reinstalled and re-grouted. After these modifications, the vibration levels were reduced by a factor of 30. The reduction in vibration level was sufficient to allow the Vision beam line to operate at full capacity for the first time since its completed construction date.

: Diagnostics↗

Technical Note: Nanometric organic photovoltaic thin film detectors for dose monitoring in diagnostic x-ray imaging

Purpose: To fabricate organic photovoltaic (OPV) cells with nanometric active layers sensitive to ionizing radiation and measure their dosimetric characteristics in clinical x-ray beams in the diagnostic tube potential range of 60–150 kVp. Methods: Experiments were designed to optimize the detector’s x-ray response and find the best parameter combination by changing the active layer thickness and the area of the electrode. The OPV cell consisted of poly (3-hexylthiophene-2,5-diyl): [6,6]-phenyl C{sub 61} butyric acid methyl ester photoactive donor and acceptor semiconducting organic materials sandwiched between an aluminum electrode as an anode and an indium tin oxide electrode as a cathode. The authors measured the radiation-induced electric current at zero bias voltage in all fabricated OPV cells. Results: The net OPV current as a function of beam potential (kVp) was proportional to kVp{sup −0.5} when normalized to x-ray tube output, which varies with kVp. Of the tested configurations, the best combination of parameters was 270 nm active layer thicknesses with 0.7 cm{sup 2} electrode area, which provided the highest signal per electrode area. For this cell, the measured current ranged from approximately 0.7 to 2.4 nA/cm{sup 2} for 60–150 kVp, corresponding to about 0.09 nA–0.06 nA/mGy air kerma, respectively. When compared to commercial amorphous silicon thin film photovoltaic cells irradiated under the same conditions, this represents 2.5 times greater sensitivity. An additional 40% signal enhancement was observed when a 1 mm layer of plastic scintillator was attached to the cells’ beam-facing side. Conclusions: Since both OPVs can be produced as flexible devices and they do not require external bias voltage, they open the possibility for use as thin film in vivo detectors for dose monitoring in diagnostic x-ray imaging.

60 APPLIED LIFE SCIENCES↗

Absolute electron density fluctuation reconstruction for two-dimensional hydrogen beam emission spectroscopy

Scrape-off layer (SOL) and edge plasma turbulence significantly contribute to the radial particle and heat transport, lowering the plasma confinement and increasing the heat load on the plasma facing components. SOL turbulence is predominantly intermittent, which manifests in the occurrence of isolated density filaments or blobs. Filaments propagate radially outward toward plasma facing components, limiting their lifetime by erosion and sputtering. To characterize this phenomenon in detail, few diagnostic techniques are available. Beam emission spectroscopy is a diagnostic capable of measuring plasma turbulence in both SOL and edge plasmas. Due to the finite lifetime of the excitation states during the beam–plasma interaction and the misalignment between the optics and the magnetic field, spatial smearing is introduced in the measurement. In this paper, a novel method is introduced to overcome this hindering effect by inverting the fluctuation response matrix on an optimally smoothed signal. We show that this method is fast and provides significantly more accurate absolute density fluctuation reconstruction than the direct inversion technique. Here, the presented method is usable for all types of beam emission diagnostics where the spatial resolution is higher than the combined smearing of the atomic physics and the observation.

47 OTHER INSTRUMENTATION↗

Diagnosing the DARHT Electron Beam-Target Interaction and Hydrodynamic Expansion [Dissertation]

Quantitative electron beam-target interaction studies on the Dual-Axis Radiographic Hydrodynamic Test (DARHT) electron linear induction accelerators have only been performed recently. This includes characterization of the temperature, density, pressure, extent, and expansion velocity of the plasma plume. The results presented in this dissertation present a detailed and unified overview of the accelerator systems, target heating physics, beam transport, and diagnostic tools. Additional information includes calibration sources, radiation hydrodynamics, spectroscopic-quality radiation transport modeling, experimental measurements, and analyses of electron beam driven aluminum experiments. The first set of spatially and temporally resolved spectroscopic measurements of electron beam driven aluminum are presented. Contamination quantification analyses are used to understand the origin of the strong Na-I 3p-3s lines that are observed in absorption within the aluminum plasma continuum. These results inform the creation of the first spectroscopic-quality radiation transport model that links several atomic physics codes to interpret the conditions from which the Na-I lines originate. A good agreement is found between the surface analysis results and the model which confirms the concentration of the sodium present within the aluminum alloy foil material. It also demonstrates, for the first time on electron beam-driven target experiments, the ability to interpret plasma conditions from measured absorption lines. In a second experimental campaign which focuses on pure aluminum, the Al-I 3p-4s and 3p3d doublets are both measured in emission. A detailed analysis of the Al-I 3p-4s doublet reveals that the lines undergo moderate self-absorption. A simple model of the self-absorption effect is successfully used to match measured spectra at various temperature/density/plasma scale length combinations. These measurements led to the realization of the minimum density that can be resolved by the spectrometers for the Al-I 3p-4s lines due to the large slit width required to observe a signal on aluminum. These measurements also demonstrate the sensitivity of visible and long wave UV spectroscopy to minor changes in both temperature and density. The simple self-absorption model will be useful for analysis of other beam-target interaction experiments with spectra exhibiting either self-absorption or full self-reversal. Substantial headway has been made on the modeling front by linking together several codes needed to model both the energy deposition, hydrodynamic motion, and atomic kinetics to produce synthetic spectral calculations that are compared with experimental measurements. There exists ample space for improvement, especially with benchmarking the hydrodynamics codes and equation-of-state tables with experimental measurements. The X-ray diagnostics required to make these new measurements along with the simulation capabilities required to interpret the results are under development and will be the subject of future studies.

43 PARTICLE ACCELERATORS↗

Muon Campus at Fermilab

The Muon Campus at Fermilab provides world class accelerator infrastructure supporting the next generation intensity frontier experiments. The anti-proton source from the Tevatron era was converted to the present day Muon Campus at the end of the collider program in 2011. Currently, the Muon Campus delivers highly polarized muon beams to the Muon g-2 experiment and in a few years, it will provide muon beams to the Mu2e experiment. The Muon g-2 experiment is a high precision test of the standard model; it is precise enough to measure QED, Weak, and QCD Standard Model contributions.The Muon g-2 experiment looks for a significant deviation from the Standard Model whereas the Mu2e experiment looks for rare processes using high intensity muon beams. The Muon g-2 experiment has measured the anomalous magnetic moment of muons to an unprecedented 460 ppb precision with Run 1 data. The experiment has completed 5 runs, accumulating 19$\times$ Brookhaven E821 data set. The Mu2e experiment has completed the construction phase and first beam to the Diagnostic Absorber was run on April 14, 2022. Installation and commissioning of the Mu2e experiment will begin in 2023 and beam commissioning and physics run is currently planned for 2026.

43 PARTICLE ACCELERATORS↗

The Thomson deflectometer: A novel use of the Thomson spectrometer as a transient field and plasma diagnostic

Laser accelerated proton beams have been used for field characterization in expanding plasmas. The Thomson parabola spectrometer, as a charged particles analyzer, also allows precise measurement of the charged particles' trajectories. The proton's deflections by fast changing plasma fields can be measured with the new design of the Thomson parabola spectrometer and, therefore, it can be applied for proton deflectometry. It is shown that from resulting spectrograms the plasma field dynamics can be reconstructed with high temporal resolution. In a proof-of-principle experiment, a weakly relativistic plasma expansion is studied as an example.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An empirical model of diagnostic x-ray attenuation under narrow-beam geometry

Purpose: The purpose of this study was to develop and validate a mathematical model to describe narrow-beam attenuation of kilovoltage x-ray beams for the intended applications of half-value layer (HVL) and quarter-value layer (QVL) estimations, patient organ shielding, and computer modeling. Methods: An empirical model, which uses the Lambert W function and represents a generalized Lambert-Beer law, was developed. To validate this model, transmission of diagnostic energy x-ray beams was measured over a wide range of attenuator thicknesses [0.49-33.03 mm Al on a computed tomography (CT) scanner, 0.09-1.93 mm Al on two mammography systems, and 0.1-0.45 mm Cu and 0.49-14.87 mm Al using general radiography]. Exposure measurements were acquired under narrow-beam geometry using standard methods, including the appropriate ionization chamber, for each radiographic system. Nonlinear regression was used to find the best-fit curve of the proposed Lambert W model to each measured transmission versus attenuator thickness data set. In addition to validating the Lambert W model, we also assessed the performance of two-point Lambert W interpolation compared to traditional methods for estimating the HVL and QVL [i.e., semilogarithmic (exponential) and linear interpolation]. Results: The Lambert W model was validated for modeling attenuation versus attenuator thickness with respect to the data collected in this study (R{sup 2} > 0.99). Furthermore, Lambert W interpolation was more accurate and less sensitive to the choice of interpolation points used to estimate the HVL and/or QVL than the traditional methods of semilogarithmic and linear interpolation. Conclusions: The proposed Lambert W model accurately describes attenuation of both monoenergetic radiation and (kilovoltage) polyenergetic beams (under narrow-beam geometry).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental analysis of a novel and low-cost pin photodiode dosimetry system for diagnostic radiology

Silicon PIN photodiode has recently found broad and exciting applications in the ionizing radiation dosimetry. In this study a compact and novel dosimetry system using a commercially available PIN photodiode (BPW34) has been experimentally tested for diagnostic radiology. The system was evaluated with clinical beams routinely used for diagnostic radiology and calibrated using a secondary reference standard. Measured dose with PIN photodiode (Air Kerma) varied from 10 to 430 μGy for tube voltages from 40 to 100 kVp and tube current from 0.4 to 40 mAs. The minimum detectable organ dose was estimated to be 10 μGy with 20% uncertainty. Results showed a linear correlation between the PIN photodiode readout and dose measured with standard dosimeters spanning doses received. The present dosimetry system having advantages of suitable sensitivity with immediate readout of dose values, low cost, and portability could be used as an alternative to passive dosimetry system such as thermoluminescent dosimeter for dose measurements in diagnostic radiology.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Phase-stable self-modulation of an electron-beam in a magnetic wiggler

Electron-beams with a sinusoidal energy modulation have the potential to emit sub-femtosecond x-ray pulses in a free-electron laser. The energy modulation can be generated by overlapping a powerful infrared laser with an electron-beam in a magnetic wiggler. Here we report on a new infrared source for this modulation, coherent radiation from the electron-beam itself. In this self-modulation process, the current spike on the tail of the electron-beam radiates coherently at the resonant wavelength of the wiggler, producing a six-period carrier-envelope-phase (CEP) stable infrared field with gigawatt power. This field creates a few MeV, phase-stable modulation in the electron-beam core. The modulated electron-beam is immediately useful for generating sub-femtosecond x-ray pulses at any machine repetition rate, and the CEP-stable infrared field may find application as an experimental pump or timing diagnostic.

wiggler↗

How to reduce Shutdown Dose Rates in ITER Diagnostics Equatorial Ports

The ITER vacuum vessel presents 54 access ports, arranged in three levels, where port plugs are inserted hosting different types of systems: test blanket modules, antennas, vacuum pumps, neutral beam injectors and diagnostics. At the equatorial level, nine out of the eighteen access ports present diagnostics port plugs, in which the diagnostics systems are deployed into three DSMs (Diagnostics Shield Modules). The DSMs, being a major constituent in volume of the port plugs, must help to fulfill the design target of Shutdown Dose Rates (SDDR) corresponding to 100 μSv.h{sup -1} after 10{sup 6} s of cooling time for planned in-situ maintenance operations in the port interspace. Additionally, the DSMs are largely responsible for the port plug drained weight limit of 45 T, which imposes limitations to the shielding technology. Up to now, all the proposed DSM designs combine differently stainless steel, water and/or B{sub 4}C as shielding to accommodate a maximum of 1.1 m{sup 3} of DSM bulk shield, contained into a L 1845 x W 518 x H 2011 mm stainless steel box weighting 5.8 T for each DSM. These proposals show insufficient shielding properties with respect to SDDR, while none of them satisfies currently the weight limit. However, during 2016, a new DSM concept has been developed, named 'modular DSM', with significant engineering advances and changes. The DSM length has been increased by 500 mm, up to 2345 mm. The SS box has been reduced to the minimum structure required, presenting the same weight while being larger and hosting a larger volume of bulk shielding inside. Thus, the volume of bulk shielding has been enlarged up to 1.5 m{sup 3} per DSM. The shielding technology is based on B{sub 4}C bricks deployed in SS trays that are attached to the vertical plates. This results in a bulk shielding made of 65% of B{sub 4}C, 10% SS and 25% void, with effective density of 2.4 g.cm{sup -3}. In summary, the modular DSM, without a weight increase, hosts extra 0.5 m3 of bulk shielding along an additional 500 mm of length, to be used with a light but highly neutron absorber, what allows fitting the weight limit of 45 T for the port plug once drained. From now, the non-modular DSMs will be referred as 'short DSMs'. The modular DSM's advantages with respect to the short DSM versions have shown that the DSMs design can be improved in generic approach, i.e. when the penetrations of the systems are not taken into consideration. A mention apart is required when port specific penetrations are considered. Provided that they will be an important radiation transmission path, their presence could significantly diminish the improvement. To clarify this issue, in this work we have carried out a nuclear analysis of the ITER equatorial port no. 11 integration considering the modular DSM. It is a first plasma port hosting the following 6 major diagnostics systems: Neutral Particle Analyzer (NPA), H-α monitor, Low Field Side (LFS) reflectometry, Visible - Ultraviolet divertor (VUV div), Visible - Ultraviolet core survey (VUV CS) and X-rays Crystal System (XRCS). For the baseline case, a SDDR matrix has been derived assigning responsibilities to the different EP no. 11 individual systems in terms of neutron flux transmission through them, and the related activation due to that neutron flux (activation of itself, but also of the rest of systems taken one by one). Different EP no. 11 configurations have been studied in addition to the baseline case. For example, the backfill of the port plug penetrations to protect all the empty space not required for systems sight. Another issue is the determination of the role of the Co impurity content minimization from 0.05 wt.% to 0.03 wt.% recently proposed. In this summary, only some results related to the baseline are given.

61 RADIATION PROTECTION AND DOSIMETRY↗

Power Density Distributions in Electron Beams

Measuring and controlling the power density distribution of electron beams used for welding is critical for producing repeatable welds and for transferring welding parameters between different machines. On any given machine, the power density distribution is controlled by defocusing the beam relative to its sharpest focused condition. However, measuring the power density distribution can be difficult due to the intense nature of welding beams and is further complicated by imperfect electron optics that can distort the beam, making it difficult to quantify. The enhanced modified Faraday cup (EMFC) diagnostic method was used here for beam analysis that utilizes computed tomography to reconstruct the beam’s power density distribution. These results were compared to the International Standards Organization (ISO) method for characterizing laser beams using a second-moment D4σ calculation. For ideal Gaussian-shaped beams, both methods would give the same result. However, for imperfect beams, the calculated D4σ diameter was shown to be about 25% larger relative to the FWe2 diameter measured by the EMFC due to the heavier weighting of data in the tails of the beam by D4σ. Finally, although both methods produce repeatable welds, it is important to understand the differences in the reported beam diameters, divergence angles, and beam parameter products when transferring parameters between machines.

36 MATERIALS SCIENCE↗

Beam dynamics simulations and measurements at the Project X Test Facility

Project X, under study at Fermilab, is a multitask high-power superconducting RF proton beam facility, aiming to provide high intensity protons for rare processes experiments and nuclear physics at low energy, and simultaneously for the production of neutrinos, as well as muon beams in the long term. A beam test facility - former known as High Intensity Neutrino Source (HINS) - is under commissioning for testing critical components of the project, e.g. dynamics and diagnostics at low beam energies, broadband beam chopping, RF power generation and distribution. In this paper we describe the layout of the test facility and present beam dynamics simulations and measurements.

43 PARTICLE ACCELERATORS↗

A model for chorus associated electrostatic bursts

The linear theory of the generation of electrostatic bursts of noise by electrons trapped in chorus wave packets is developed for a finite temperature electron beam and a Maxwellian elecron and ion background. The growth rates determined qualitatively in good agreement with those obtained by previous authors from a more idealized model. Two connected instability mechanisms seem to be occurring: a beam plasma (electron-ion two-stream) instability commonly associated with intensification of the chorus power levels, and a transitional or borderline resistive medium instability commonly associated with chorus hooks. The physical reasons for the two mechanisms is discussed. In the second case electron beams are difficult to identify in the particle data. An expression is obtained for the maximum growth rate in terms of the ratios of the beam and electron thermal velocities to the beam velocity, and of the beam density to plasma density. It is anticipated that this may allow the observed peak in the electrostatic noise spectrum to be used as a diagnostic for the beam characteristics. Previously announced in STAR as N84-12832

Grabbe, C. L.↗

Transport and Measurements of High-Current Electron Beams from X pinches

Generation of electron beams is an unavoidable property of X-pinches and other pulsed-power-driven pinches of different geometry. Some issues concerning high-current electron beam transport from the X pinch to the diagnostic system and measurements of the beam current by Faraday cups with different geometry's are discussed. Of particular interest is the partially neutralized nature of the beam propagating from the X-pinch to a diagnostic system. Two scenarios of electron beam propagation from X-pinch to Faraday cup are analyzed by means of computer simulation using the PIC-code KARAT. The first is longitudinal neutralization by ions extracted from plasma at an output window of the X-pinch diode; the second is the beam transport through a plasma background between the diode and a diagnostic system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗