Hydrogen Based Energy Storage System for Integration with Dispatchable Power Generator (Phase I Feasibility Study)

This project examined the feasibility of integrating hydrogen generation, storage, and use as a means to decarbonize campus activities while retaining the ability to utilize the existing natural gas fired combined heat and power system installed at the campus of the University of California @ Irvine. Analysis of specific potential sites for the integrated system identified a location adjacent to the existing central plant which resulted in minimization of interconnections. A strategy based on use of commercial electrolyzers and gas storage was identified. Primary technology advancements are required for the gas turbine to accommodate higher levels of hydrogen and the integrated controls. The project indicated challenges for adopting the proposed strategy with the present rates and constraints. The availability of a relatively low-cost biogas resource by the campus already decarbonizes the gas turbine to some extent. In the absence of this resource, procurement of electricity directly from large scale renewable operations could facilitate lower electricity costs. Additional solar resources on campus could also help in this regard. The gas turbine cannot be operated below 50% capacity due to air permit constraints. Using the otherwise curtailed gas turbine operation to generate hydrogen via electrolysis by consuming natural gas is not highly efficient and therefore leads to relatively high costs of electricity returned. Several scenarios demonstrate potential for effective decarbonization, yet most involve lower and lower capacity factor for the legacy gas turbine which is not a good use of the asset. A small gas turbine output with higher efficiency operation would help. As would ability to export electricity to the grid. Certainly current rate structures and operational scenarios are less attractive than other possible future structures which should be pushed for in the future.

03 NATURAL GAS↗

Rock Valley Direct Comparison Relocation Working Group Location Results and Recommendations (Version 4.0)

The Source Physics Experiments (SPE) were designed to improve our physics-based understanding of explosion sources for the purposes of nuclear test monitoring. Phase I consisted of 6 chemical explosions in the Climax Stock Granite of the Nevada National Security Site (NNSS), while Phase II consisted of 4 explosions in a contrasting dry alluvium geology (DAG) in Yucca Flat, providing essential data in various media and emplacement conditions to further modeling efforts. For Phase III, the Rock Valley Direct Comparison (RVDC) seeks to directly compare earthquake and explosion source types. An unusually shallow series of events in 1993 along the Rock Valley Fault Zone in the southeastern portion of the NNSS has been targeted for this direct comparison. Depth ranges for the events, previously estimated to be less than 3 km, is achievable by modern drilling techniques and accessibility to the epicentral locations would require minimal improvements to the infrastructure. The events providing this unique opportunity for direct comparison are the focus of this report.

58 GEOSCIENCES↗

Evaluating Nationwide Supply Chain for Circularity of PET and Olefin Plastics

PET (Polyethylene Terephthalate, #1) and olefin plastics including HDPE (High Density Polyethylene, #2), LDPE/LLDPE (Low Density/Linear Low-Density Polyethylene, #4) and PP (Polypropylene, #5) together comprise nearly 80% of the U.S. plastic market. Due to their high market share and extensive application in packaging these polymers have better potential for circularity than other polymer types. To understand the potential of future scenarios with higher recycling rates, supply chain scenarios for PET and olefin plastic packaging need to be analyzed with increased availability and collection of plastics. Currently there exists a knowledge gap to understand the circular supply chain on a national level. Performing a nationwide analysis introduces certain challenges such as variability in the plastic mix of the recycling stream in different municipalities, lack of collection of some types of plastics, regional differences in cost and estimating a national supply curve based on state level access rate and participation rate. Currently, a limited number of Plastic Reclaimers recycle the nation’s collected plastic involving transportation over long distances surpassing state boundaries. Modeling a nationwide scenario instead of regional/state based scenario will facilitate transportation beyond state boundaries for the development of a circular economy. A Mixed-integer Linear Programming model was developed, to identify the optimal location and capacity of the Material Recovery Facilities (MRFs) nationwide subject to maximizing the profit margin of the industrial entities within the model. We considered three different scenarios including the base case scenario (S1) collecting 2.27 million metric tons/year as well as two additional scenarios with available plastic supply of 1.8 times (S2) and 2.2 times (S3) of the base case scenario. The model identified 166, 275 and 319 counties as potential MRF locations for scenarios S1, S2 and S3 respectively. Compared to the existing number of counties having MRFs in the US, the model results indicated a reduction of 38% of MRFs for S1. For S2 and S3, the number of counties with MRFs increased 3% and 20% respectively compared to counties currently with MRFs. The average profit remains constant between $180-$181/ton regardless of the increased plastic collection.

54 - ENVIRONMENTAL SCIENCES/GLOBAL CLIMATE CHANGE ↗

Data compression system using base values and methods thereof

In some embodiments, a memory controller in a processor includes a base value cache, a compressor, and a metadata cache. The compressor is coupled to the base value cache and the metadata cache. The compressor compresses a data block using at least a base value and delta values. The compressor determines whether the size of the data block exceeds a data block threshold value. Based on the determination of whether the size of the compressed data block generated by the compressor exceeds the data block threshold value, the memory controller transfers only a set of the compressed delta values to memory for storage. A decompressor located in the lower level cache of the processor decompresses the compressed data block using the base value stored in the base value cache, metadata stored in the metadata cache and the delta values stored in memory.

Seyedzadehdelcheh, SeyedMohammad↗

Data compression system using base values and methods thereof

In some embodiments, a memory controller in a processor includes a base value cache, a compressor, and a metadata cache. The compressor is coupled to the base value cache and the metadata cache. The compressor compresses a data block using at least a base value and delta values. The compressor determines whether the size of the data block exceeds a data block threshold value. Based on the determination of whether the size of the compressed data block generated by the compressor exceeds the data block threshold value, the memory controller transfers only a set of the compressed delta values to memory for storage. A decompressor located in the lower level cache of the processor decompresses the compressed data block using the base value stored in the base value cache, metadata stored in the metadata cache and the delta values stored in memory.

Seyedzadehdelcheh, Seyed Mohammad↗

Hanford Waste Treatment Plant Effluent Management Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The Hanford Tank Waste Treatment and Immobilization Plant Effluent Management Facility (EMF) stack monitor location was qualified using a combination of scale model stacks to mitigate the risk of identifying that the sampling location does not meet the qualification criteria on the full-scale stack. The LV-S1 scale model stack was used as a baseline, augmented by the LB-S1 and LV-S2 scale model stacks to address the Direct Feed Low Activity Waste Effluent Management Facility Vessel Vent Process (DVP) injection into the main Active Confinement Ventilation (ACV) system duct. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling locations were geometrically similar to the actual stack, and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. The LV-S1, LB-S1, and LV-S2 scale model stack tests have met the criteria of the ANSI/HPS N13.1-1999 standard to demonstrate the stack sampling locations are well mixed. Verification tests of the EMF stack were performed at normal operating conditions. The minimum 1/6 DV value and the maximum 6 DV value from the scale model testing determine the range of stack flow rates for which the full-scale stack may be operated while remaining in compliance with the stack verification criterion. A practical range for the full-scale stack qualification uses the average DV through 6 DV from the scale model tests to compute the corresponding flow rates. Table S1 lists the operating flow rate along with the average and maximum qualified stack flow rate based on the LV-S1 scale model DV values. The operating flow is below the maximum qualified stack flow, which means that the scale model test results are acceptable for stack qualification. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be ≤20°. Second, the velocity uniformity at the full-scale stack must be ≤20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack test at the EMF. Flow angle results were <5°; all flow angle results were within the ≤20° criterion. The velocity uniformity results for each test condition ranged between 2.2% COV and 4.3% COV, all of which were within the range of the target % COV values from the scale model tests on the LV-S1, LB-S1, and LV S2 scale models. Based on these stack verification test results, the EMF filtered exhaust stack sampling location meets the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all planned fan operating configurations. This includes each combination of ACV fans with DVP exhausters. Further changes to the system configuration or operating conditions that are outside the qualified flow rates described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Hi-GAL compact source catalogue – II. The 360° catalogue of clump physical properties

ABSTRACT We present the 360° catalogue of physical properties of Hi-GAL compact sources, detected between 70 and 500 $\mu$m. This release not only completes the analogous catalogue previously produced by the Hi-GAL collaboration for −71° ≲ ℓ ≲ 67°, but also meaningfully improves it because of a new set of heliocentric distances, 120 808 in total. About a third of the 150 223 entries are located in the newly added portion of the Galactic plane. A first classification based on detection at 70 $\mu$m as a signature of ongoing star-forming activity distinguishes between protostellar sources (23 per cent of the total) and starless sources, with the latter further classified as gravitationally bound (pre-stellar) or unbound. The integral of the spectral energy distribution, including ancillary photometry from λ = 21 to 1100 $\mu$m, gives the source luminosity and other bolometric quantities, while a modified blackbody fitted to data for $\lambda \ge 160~\mu$m yields mass and temperature. All tabulated clump properties are then derived using photometry and heliocentric distance, where possible. Statistics of these quantities are discussed with respect to both source Galactic location and evolutionary stage. No strong differences in the distributions of evolutionary indicators are found between the inner and outer Galaxy. However, masses and densities in the inner Galaxy are on average significantly larger, resulting in a higher number of clumps that are candidates to host massive star formation. Median behaviour of distance-independent parameters tracing source evolutionary status is examined as a function of the Galactocentric radius, showing no clear evidence of correlation with spiral arm positions.

Elia, Davide↗

Illinois Storage Corridor, CarbonSAFE Phase III: UIC Class VI Permitting Plan

The Illinois Storage Corridor (ISC) project evaluated two distinct sites to determine the feasibility of commercial-scale CO₂ storage at each. The project leveraged the region's exceptional geological characteristics, particularly the well-characterized Cambro-Ordovician Storage Complex, to enable permanent geological storage of more than 50 million tonnes of CO₂ over 30 years. The two storage sites are located at One Earth Energy (OEE) facility in northcentral Illinois and Prairie State Generating Company (PSGC) in southcentral Illinois. Once operational, these facilities will combine to capture and store more than 6.5 million tonnes of CO₂ per year, positioning the ISC among the largest carbon storage regions globally. Preliminary homogeneous dynamic modeling based on regional and site-specific reservoir characteristics indicates promising injection capabilities at both locations. For the OEE site, modeling predicts a maximum allowable injection rate of 3.7 MTPA, with a baseline scenario of 1.7 MTPA over 30 years producing a CO₂ plume radius of 1.4 miles at end of injection. For the PSGC site, incorporating recent well data, modeling indicates a single-well maximum injection rate of 2.1 MTPA, with a plume radius of 4.2 miles at end of injection for the 60 MT over 30 years scenario. The primary objective of this CarbonSAFE Phase III project is to develop and submit Class VI Underground Injection Control (UIC) permit applications to the U.S. Environmental Protection Agency Region 5. The permitting plan outlines comprehensive site characterization, Area of Review delineation, monitoring programs, well construction designs, financial responsibility provisions, and post-injection site care procedures necessary to demonstrate safe, permanent CO₂ storage protective of underground sources of drinking water. Three UIC Class VI permit applications for the OEE site were submitted to EPA in October 2022 and are progressing through technical review, with final permit decision projected by June 2026. Through five rounds of Requests for Additional Information and responses, the applications have been refined to address computational modeling, area of review delineation, well integrity, monitoring protocols, and financial assurance requirements. For the PSGC site, finalized characterization and permitting documentation was delivered directly to the facility in July 2023 due to business constraints precluding formal federal regulatory submission. This comprehensive permitting effort builds upon extensive prior subsurface evaluations and demonstration projects that have confirmed the feasibility of widespread commercial-scale carbon storage in the region.

01 COAL, LIGNITE, AND PEAT↗

Hanford Waste Treatment Plant Effluent Management Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The Hanford Tank Waste Treatment and Immobilization Plant Effluent Management facility (EMF) stack monitor location was qualified using the LV-S1 scale model stack as a baseline, augmented by the LB-S1 and LV-S2 scale model stacks to address the Direct Feed Low Activity Waste Effluent Management Facility Vessel Vent Process (DVP) injection into the main Active Confinement Ventilation (ACV) system duct. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale models and its sampling locations were geometrically similar to the actual stack and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the EMF stack was performed at normal operating conditions. The minimum 1/6 DV value, along with the maximum 6 DV value from the scale model testing determines the range of stack flow rates for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. Based on the LV-S1 scale model test DV values, the corresponding stack flow rates for the EMF stack are as listed in Table S1. Table S1. Effluent Management Facility Stack Qualified Flow Range. Stack Parameter EM-1 Minimum Qualified Stack Flow (scfm) 781 Maximum Qualified Stack Flow (scfm) 53,432 The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be =20°. Second, the velocity uniformity at the full-scale stack must be =20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack test at the EMF. Flow angle results were less than 5°; all flow angle results were within the =20° criterion. The velocity uniformity results for each test condition ranged between 2.2% COV and 4.3% COV, which were all within the range of the target % COV values from the scale model tests on the LV-S1, LB-S1, and LV S2 scale models. Based on these stack verification test results, the EMF filtered exhaust stack sampling location meets the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all fan operating configurations. This includes each combination of ACV fan with the DVP exhausters. Further changes to the system configuration or operating conditions that are outside the qualified flow rates described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Investigating the interactions between wakes and floating wind turbines using FAST.Farm

As floating offshore wind progresses to commercial maturity, wake and array effects across a farm of floating offshore wind turbines (FOWTs) will become increasingly important. While wakes of land-based and bottom-fixed offshore wind turbines have been extensively studied, only recently has this topic become relevant for floating turbines. This work presents an investigation of the mutual interaction between the motions of floating wind turbines and wakes using FAST.Farm. While FAST.Farm has been extensively validated across a wide range of conditions, it has never been validated for FOWT applications. Hence, in the first part of this work, we validate FAST.Farm by comparing simulations of a single FOWT against high-fidelity results from large-eddy simulations available in the literature. The validation is based on wake meandering, mean wake deflection, and velocity deficit at different downstream locations. This validation showed that the original axisymmetric (polar) wake model of FAST.Farm overpredicts the vertical wake deflection induced by shaft tilt and floater pitch, while the new curled wake model is capable of properly capturing the vertical wake deflection. In the second part, we use FAST.Farm to analyze a small three-unit array of FOWTs with a spacing of 7 diameters across a wide range of environmental conditions. The same National Renewable Energy Laboratory 5 MW reference wind turbine atop the OC4-DeepCwind semisubmersible is adopted for the three FOWTs and for the validation against high-fidelity simulations. To assess the effect of the floating substructure, we compare the power production, tower-base moments, and blade-root moments obtained for the floating turbines with the results obtained in a fixed-bottom configuration. The main differences introduced by the floating substructure are the motions induced by the waves, the change in the natural frequencies of the tower caused by differences in the boundary condition at its base, and the larger vertical deflection of the wake deficit due to the mean pitch of the platform. The impact of these differences, as well as other minor effects, are analyzed in detail.

16 TIDAL AND WAVE POWER↗

Hot-Carrier Extraction in Nanowire-Nanoantenna Photovoltaic Devices

Nanowires bring new possibilities to the field of hot-carrier photovoltaics by providing flexibility in combining materials for band engineering and using nanophotonic effects to control light absorption. Previously, an open-circuit voltage beyond the Shockley–Queisser limit was demonstrated in hot-carrier devices based on InAs–InP–InAs nanowire heterostructures. However, in these first experiments, the location of light absorption, and therefore the precise mechanism of hot-carrier extraction, was uncontrolled. In this study, we combine plasmonic nanoantennas with InAs–InP–InAs nanowire devices to enhance light absorption within a subwavelength region near an InP energy barrier that serves as an energy filter. From photon-energy- and irradiance-dependent photocurrent and photovoltage measurements, we find that photocurrent generation is dominated by internal photoemission of nonthermalized hot electrons when the photoexcited electron energy is above the barrier and by photothermionic emission when the energy is below the barrier. We estimate that an internal quantum efficiency up to 0.5–1.2% is achieved. Insights from this study provide guidelines to improve internal quantum efficiencies based on nanowire heterostructures.

14 SOLAR ENERGY↗

Seismic attenuation system for a nuclear reactor

A system for attenuating seismic forces includes a reactor pressure vessel containing nuclear fuel and a containment vessel that houses the reactor pressure vessel. Both the reactor pressure vessel and the containment vessel include a bottom head. Additionally, the system includes a base support to contact a support surface on which the containment vessel is positioned in a substantially vertical orientation. An attenuation device is located between the bottom head of the reactor pressure vessel and the bottom head of the containment vessel. Seismic forces that travel from the base support to the reactor pressure vessel via the containment vessel are attenuated by the attenuation device in a direction that is substantially lateral to the vertical orientation of the containment vessel.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

ARETE: Accurate Error Assessment via Machine Learning-Guided Dynamic-Timing Analysis

Nanometer circuits are increasingly prone to timing errors, escalating the need for fault injection frameworks to accurately evaluate their impact on applications. Here in this paper, we propose ARETE, a novel cross-layer, fault-injection framework that combines dynamic-binary instrumentation with machine learning-guided dynamic-timing analysis. ARETE enables accurate fault-injection into any application by estimating the location of the injecting errors via dynamic-timing analysis. To accelerate fault-injection, we develop a novel, data-aware, machine learning-based mechanism that dynamically pre-selects the error-prone instructions and limits the application of the costly dynamic-timing analysis only to them. To evaluate ARETE's accuracy, our fully automated toolflow is configured to support fault-injection based on detailed post-layout gate-level simulations as well as via existing workload-agnostic error models. Our results for various workloads, including an autonomous-driving library, show that the location and time of injected errors performed by ARETE, is 89.9% consistent with fault-injection based on full gate-level simulation. On average, ARETE executes 84.6x faster than gate-level simulation and at a cost of 3.4% loss in the program output quality estimation. When compared to the existing statistical fault-injection tools that are based on workload-agnostic error models, ARETE improves the accuracy of fault-injection rate and output quality estimation by 143.9% and 40.4% on average, respectively.

97 MATHEMATICS AND COMPUTING↗

Historic climate, cosmogenic 10Be, denudation-rate, and geospatial datasets from the Pikes Peak region, Colorado, USA

This data package contains geographic information system (GIS) layers and tabular datasets associated with the study of elevation-dependent denudation rates on Pikes Peak in the Front Range of the Rocky Mountains, Colorado, USA. The package includes GIS layers used to produce the study-area map, including sample locations, sample watershed boundaries, the Pikes Peak batholith, Pleistocene glacier extent, weather station locations, and elevation and hillshade rasters, together with comma-separated value (CSV) tables and matching CSV data dictionaries. These mapped layers provide the geographic framework for interpreting denudation patterns across the Pikes Peak region and for relating sample locations to watershed geometry, bedrock setting, glacial history, and nearby climate stations. The first group of tables reports climate and geospatial context for the study area. These files include station-based temperature and precipitation data used to characterize elevational gradients in mean annual climate and monthly climate seasonality, sample locations, denudation-rate and topographic metrics, fixed frost-cracking model parameters, frost-cracking intensity and precipitation-frequency metrics, and stream-power inversion results. Together, these data provide the basis for evaluating how denudation varies with elevation, climate, and landscape form across sampled catchments on Pikes Peak. The second group of tables reports cosmogenic nuclide and erosion-model results used in the denudation analysis. Included files contain accelerator mass spectrometry (AMS) measurements for in situ-produced cosmogenic beryllium-10 (10Be), including sample identifiers, measured 10Be:9Be ratios, analytical uncertainties, carrier mass, quartz mass, blank corrections, blank-group statistics, and calculated 10Be concentrations and uncertainties. Additional tables summarize stream-power-law inversion results for sampled catchments, including optimized model parameters, predicted erosion rates, residual metrics, channel-pixel counts, and convergence status, as well as regression equations and summary statistics used to evaluate relationships among elevation, climate, frost cracking, precipitation forcing, and denudation rate. The package contains GIS files, comma-separated value files (.csv), Microsoft Excel files (.xlsx), CSV data dictionaries, a file-level metadata table, and a readme text file.

10Be cosmogenic nuclides↗

Emission Inventories from Natural Gas Storage Facilities using Regional Frequency Comb Laser Monitoring and Aircraft Flyovers. Final Report

The project centers around a ground-based regional methane sensor developed by the CU/NIST team members under the DOE ARPA-E MONITOR program, and sophisticated aircraft measurement techniques developed by the UCD/Scientific Aviation team (responsible for a recent Science publication quantifying the Aliso Canyon storage field release). The dual frequency-comb spectrometer is an invisible, eye-safe laser capable of measuring atmospheric methane concentrations along beam paths 1+ miles in length with high precision and stability (<1 ppb methane over 1 mile). The CU/NIST team has developed a unique approach to using a single, central spectrometer to locate and size methane emissions as small as 6 scfh from specific gas field structures within the 1+ mile range of the laser. Deployment involves the stationing of small cubic mirrors at strategic locations across the gas storage site. The mirrors direct light from the spectrometer back to a detector, where methane concentrations are recorded based on light absorption at specific wavelengths. The measurements are coupled with high resolution gas transport models based on meteorological measurements (wind, etc.) to determine the precise location and emission rate of methane sources. The calibration-free and continuous nature of dual frequency-comb spectrometer measurements means that a large area can be monitored continuously for temporal variability of emissions over long periods of time. The aircraft measurements involve spiral flights around storage facilities with a sensitive ethane/methane measurement package. Upwind/downwind concentration comparisons and wind data provide total facility emissions data. During this project, a new micrometeorological package was integrated onto the Scientific Aviation aircraft to provide even greater emissions quantification capability. In this project, the ground-based measurement system was deployed for 11 months (to capture seasonal variability) at a West Coast storage facility, together with a campaign of twice monthly aircraft total facility emissions flights. The data from these two modalities was combined to quantify the methane emissions from the facility with first-of-its-kind temporal and spatial detail. Concurrent with this deployment, the aircraft team performed flights to quantify emissions at a wider array of previously un-surveyed storage sites. The ground-based measurement system was then moved to an additional site of differing total storage and delivery capacity. Aircraft mass balance flights continued, repeatedly surveying (twice monthly) this site, as well as surveying a large number of previously un-assessed sites spanning a variety of size, reservoir type and age. Assessment of ground-based, temporally and spatially detailed methane emissions information alongside aircraft-derived methane total facility emissions information led to an improved understanding of emissions, relevant for inventories of the natural gas storage sector. In particular, this work provided temporal detail (seasonal of emissions and frequency of leaks) to stakeholders and personnel responsible for updates to the EPA’s GHGI. The impact of the proposed work has been a dramatic improvement in the temporal, spatial, and site- and type- specific detail and quantification of emissions inventories for the natural gas storage sector. This work directly benefits the EPA’s GHGI, directly ameliorates the environmental impacts and public health and safety of the natural gas storage sector, and aids policymakers and industry to make sound choices with respect to management and regulation.

03 NATURAL GAS↗

Multi-Source Data Aggregation and Real-Time Anomaly Classification and Localization in Power Distribution Systems

This paper proposes a real-time anomaly location and classification framework for power distribution systems to simultaneously determine the type of anomaly (i.e., short-circuit fault, cyber attack, DER switching) and its location. The proposed framework employs the data aggregation module to collect the measurement data from multiple field devices operating at different sampling rates, such as protection relays and D-PMUs. The output of the data aggregation is then fed into a multi-task learning-based long-based short-term memory (MTL-LSTM) to classify the type of anomaly and the location in two separate tasks. The proposed MTL-LSTM approach can be utilized in real-time operation in order to distinguish between normal and several anomalous operations and locate the anomaly. The proposed framework is tested on a modified IEEE 33-bus test feeder benchmark that integrates solar generation and energy storage. Furthermore, the results show that the proposed framework can locate and classify anomalies for several operation conditions with more than 96% accuracy. Further experiments highlight the impact of aggregating multiple sources of data on the performance of the proposed model.

24 POWER TRANSMISSION AND DISTRIBUTION↗