Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “arterial”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Monogroove heat pipe design: Insulated liquid channel with bridging wick

A screen mesh artery supported concentrically within the evaporator section of a heat pipe liquid channel retains liquid in the channel. Continued and uniform liquid feed to the heat pipe evaporation section (20) during periods of excessive heat transfer is assured. The overall design provides high evaporation and condensation film coefficients for the working fluid by means of the circumferential grooves in the walls of the vapor channel, while not interfering with the overall heat transport capability of the axial groove. The design has particular utility in zero-g environments.

Alario, J. P.↗

Role of muscle mass and mode of contraction in circulatory responses to exercise

The roles of the mode of contraction (dynamic or static) and active muscle mass in determining the cardiovascular response to exercise has been investigated experimentally in six normal men. Exercise consisted of static handgrip and dynamic handgrip exercise, and static and dynamic knee extension for a period of six minutes. Observed increases in mean arterial pressure after exercise were similar for each mode of contraction, but larger for knee extension than handgrip exercise. Cardiac output increased more for dynamic than for static exercise and for each mode more for knee exercise than for handgrip exercise. Systemic resistance was found to be lower for dynamic than for static exercise, and to decrease from resisting levels by about one third during dynamic knee extension. It is shown that the magnitude of cardiovascular response is related to active muscle mass, but is independent of the contraction mode. Equalization of cardiovascular response was achieved by proportionately larger increases in cardiac output during dynamic exercise. The complete experimental results are given in a table.

Lewis, S. F.↗

Dynamical relations for left ventricular ejection - Flow rate, momentum, force and impulse

An investigation was carried out to quantitatively evaluate left ventricular volume flow rate, momentum, force and impulse derived from application of conservation principles for mass and momentum of blood within the ventricle during the ejection phase. An automated digital image processing system was developed and applied to left ventricular angiograms which are computer processed and analyzed frame by frame to determine the dynamical relations by numerical methods. The initial experience with force and impulse has indicated that neither quantity seemed to be a sensitive indicator of coronary artery disease as evaluated by qualitative angiography for the particular patient group studied. Utilization of the dynamical relations in evaluating human left ventricular performance requires improved means of measurement and interpretation of clinical studies.

Back, L. H.↗

Visceral predictors of cardiovascular deconditioning in late middle-aged men

A number of visceral and behavioral factors connected with cardiovascular deconditioning were investigated, in order to identify a method for predicting the degree of orthostatic intolerance to spaceflight in several late-middle-aged men (55-65 years). Preliminary measurements were made of: mean arterial blood pressure plasma cortisol levels; and norepinephrine levels. Measurements of core temperature; plasma epinephrine level and subjective arousal from sleep were also obtained. Pairwise correlations were found for each of the variables and the time-to-blackout due centrifugal acceleration of up to +3 Gz. It is shown that the men with relatively low resting blood pressure were at greater risk of developing the clinical signs of cardiovascular deconditioning than were the men with higher basal blood pressure. Some applications of the experimental results to the development of selection criteria for Shuttle crews are discussed.

Goldwater, D. J.↗

High performance flexible heat pipes

A Phase I SBIR NASA program for developing and demonstrating high-performance flexible heat pipes for use in the thermal management of spacecraft is examined. The program combines several technologies such as flexible screen arteries and high-performance circumferential distribution wicks within an envelope which is flexible in the adiabatic heat transport zone. The first six months of work during which the Phase I contract goal were met, are described. Consideration is given to the heat-pipe performance requirements. A preliminary evaluation shows that the power requirement for Phase II of the program is 30.5 kilowatt meters at an operating temperature from 0 to 100 C.

Shaubach, R. M.↗

From Mars to man - Biomedical research at the Jet Propulsion Laboratory

In the course of the unmanned exploration of the solar system, which the California Institute of Technology's Jet Propulsion Laboratory has managed for NASA, major advances in computerized image processing, materials research, and miniature electronics design have been accomplished. This presentation shows some of the imaging results from space exploration missions, as well as biomedical research tasks based in these technologies. Among other topics, the use of polymeric microspheres in cancer therapy is discussed. Also included are ceramic applications to prosthesis development, laser applications in the treatment of coronary artery disease, multispectral imaging as used in the diagnosis of thermal burn injury, and some examples of telemetry systems as they can be involved in biological systems.

Beckenbach, E. S.↗

High-Performance Heat Pipe With Screen Mesh

Liquid distributed more evenly in evaporator section. Improved heat pipe contains an artery and wick rolled from stainless-steel screen of 180 mesh (openings about 80 micrometers). Screen material helps to prevent dryout in evaporator section by conducting liquid through hotspots and to vaporchannel wall. Insert reduces incidence of dryout at hotspots or during intervals of general thermal overload.

Alario, J. P.↗

Cardiovascular dynamics associated with tolerance to lower body negative pressure

The purpose of this investigation was to identify cardiovascular responses associated with tolerance to lower body negative pressure (LBNP). Eighteen men, ages 29-51 years, were categorized as high (HT) or low (LT) LBNP-tolerant based on a graded presyncopal-limited LBNP exposure criterion of -60 mm Hg relative to ambient pressure. Groups were matched for physical characteristics and pre-LBNP cardiovascular measurements, with the exceptions of greater (p less than 0.05) end-diastolic volume and cardiac output in the HT group. During peak LBNP, cardiac output was similar in both groups, although the HT group displayed a greater heart rate (p less than 0.05). In both groups, venous return appeared to limit cardiac output resulting in decreased arterial pressure. Tolerance to LBNP did not appear solely dependent on the absolute amount of blood pooled in the legs since the HT group demonstrated a greater (p less than 0.05) peak LBNP-induced increase in midthigh-leg volume. Greater tolerance to LBNP was associated with a larger pre-LBNP cardiac output reserve and higher compensatory increases in heart rate and peripheral resistance.

Sather, T. M.↗

Advanced thermal energy management: A thermal test bed and heat pipe simulation

Work initiated on a common-module thermal test simulation was continued, and a second project on heat pipe simulation was begun. The test bed, constructed from surplus Skylab equipment, was modeled and solved for various thermal load and flow conditions. Low thermal load caused the radiator fluid, Coolanol 25, to thicken due to its temperature avoided by using a regenerator-heat-exchanger. Other possible solutions modeled include a radiator heater and shunting heat from the central thermal bus to the radiator. Also, module air temperature can become excessive with high avionics load. A second preoject concerning advanced heat pipe concepts was initiated. A program was written which calculates fluid physical properties, liquid and vapor pressure in the evaporator and condenser, fluid flow rates, and thermal flux. The program is directed to evaluating newer heat pipe wicks and geometries, especially water in an artery surrounded by six vapor channels. Effects of temperature, groove and slot dimensions, and wick properties are reported.

Barile, Ronald G.↗

Cardiovascular dynamics during the initial period of head-down tilt

The cardiovascular response to 1 h of 60-deg head-down tilt was studied in 12 male subjects, ages 30-39 years, to simulate the early effects of weightlessness. Fluid shifts, hemodynamic variables, and indices of myocardial contractility were evaluated by utilizing electrocardiography, systolic time intervals, impedance cardiography, sphygmomanometry, and measurement of calf circumference. Most cardiovascular variables remained stable throughout the initial 30 min of the protocol, even though translocation of fluid from the legs to the thorax commenced immediately with the onset of head-down tilt. In contrast, minutes 30-60 were characterized by reduced stroke volume, cardiac output, mean stroke ejection rate, and Heather index concomitant with an elevation in mean arterial pressure. Intrathoracic fluid volume continued to increase, while leg volume continued to decrease. This latter physiological response suggests intrathoracic sequestration of fluid volume; blood was apparently redistributed to the pulmonary circulation rather than being retained in the great veins.

Tomaselli, Clare Marie↗

Echocardiographic evaluation of Space Shuttle crewmembers

Echocardiographic measurements of left ventricular volume were obtained from 17 members of four Space Shuttle crews before and after 5- to 8-day space flights. Measurements obtained 1 h after landing indicated increases in the heart rate (HR), mean arterial pressure, and systemic vascular resistance values. On the other hand, the end-diastolic volume index (EDVI) fell 17 ml/sq m, and the stroke volume index (SVI) fell 15 ml/sq m. Measurements taken 1-2 weeks later demonstrated that the HR values returned to normal, but the EDVI and SVI values remained significantly below preflight levels, despite the ability of the subjects to ambulate and exercise. The results indicate that a space flight induces significant changes in heart volume affecting the left-ventricle function. It is suggested that the prolonged recovery period is related to the high level of aerobic conditioning in these subjects.

Bungo, M. W.↗

Microcirculatory fluid dynamics in weightlessness and simulated weightlessness

The method of Smith et al. (1985), which makes it possible to simultaneously measure the macrocirculation and microcirculation in an unanesthetized rat, was used to study the effect of acute hypokinesia on the rat microvascular system. The measurements yielded values of the length, diameter, and number of arteriolar and venular vessels; vascular patterns; branching ratios; and the amplitude and frequency of vasomotion. Early effects (30-60 min after the start of the head-down tilt) include a 10 percent increase in the diameter of arterioles, a slight increase of heart rate and mean arterial blood pressure, and an increase in the heart rate-pulse pressure product, with most of the changes returning to normal after 2-3 h. The baroreceptor reflex index was reduced by almost 50 percent for the first 2 h, but rebounded to almost 3 times the control value after 3 h. This indicates that, in spite of relatively small changes in gross hemodynamic parameters, the cardiovascular function is altered significantly during the acute phase of hypokinesia.

Hutchins, P. M.↗

Experimenting With Baroreceptor Reflexes

Carotid arteries stimulated by pressure or suction on neck. Baro-Cuff is silicone-rubber chamber that fits on front of subject's neck. Electronic system, stepping motor, bellows, and umbilical tube furnish controlled pressure to chamber. Pressure sensor provides feedback to microprocessor in electronic system. Developed to study blood-pressure-reflex responses of astronauts in outer space. Useful for terrestrial studies of patients with congestive heart failure, chronic diabetes mellitus, and other conditions in which blood-pressure-reflex controls behave abnormally.

Eckberg, Dwain L.↗

Aerobic fitness in women and responses to lower body negative pressure

The role of tolerance to orthostatic stress in the maintenance of high aerobic fitness in women was investigated by examining the responses of heart rate, stroke volume, cardiac output, Heather index of contractility, arterial pressure, peripheral resistance, change in calf circumference, and thoracic impedance of healthy female subjects to lower body negative pressure (LBNP) applied for 5 min at -50 mm Hg or until a subject became presyncopal. The testing protocol involved a stepwise reduction in pressure and consisted of two parts: an LBNP test in supine position followed by a treadmill test to peak aerobic capacity. Women were found to exhibit the same response pattern to LBNP as was previously reported by Convertino et al. (1984) for men. The results do not support the hypothesis that orthostatic tolerance in women is inversely related to aerobic fitness, as demonstrated by a finding that the peak aerobic capacity of subjects who became presyncopal did not differ from the peak of the tolerant subjects, and that hemodynamic responses to LBNPL were not a function of aerobic capacity.

Frey, Mary Anne Bassett↗

Space erectable radiator system development

The NASA Space Station's Space Erectable Radiator System features modular radiator panels with high-capacity tapered artery heat pipes bonded within their aluminum honeycomb structures. Simple, dry aluminum-to-aluminum thermal contact surfaces are used for the connections, thereby requiring no fluid joints; a uniformly distributed clamping force at the radiator panel-to-thermal transport loop interface heat exchange surface yields high thermal contact conductance as well as minimum area and weight for the requisite performance. The design has been optimized for weight and cost.

Oren, J. A.↗

Development of an integrated heat pipe-thermal storage system for a solar receiver

An integrated heat pipe-thermal storage system was developed as part of the Organic Rankine Cycle Solar Dynamic Power System solar receiver for space station application. The solar receiver incorporates potassium heat pipe elements to absorb and transfer the solar energy within the receiver cavity. The heat pipes contain thermal energy storage (TES) canisters within the vapor space with a toluene heater tube used as the condenser region of the heat pipe. During the insolation period of the earth orbit, solar energy is delivered to the heat pipe. Part of this thermal energy is delivered to the heater tube and the balance is stored in the TES units. During the eclipse period of earth orbit, the stored energy in the TES units is transferred by the potassium vapor to the toluene heater tube. A developmental heat pipe element was constructed that contains axial arteries and a distribution wick connecting the toluene heater and the TES units to the solar insolation surface of the heat pipe. Tests were conducted to demonstrate the heat pipe, TES units, and the heater tube operation. The heat pipe element was operated at design input power of 4.8 kW. Thermal cycle tests were conducted to demonstrate the successful charge and discharge of the TES units. Axial power flux levels up to 15 watts/sq cm were demonstrated and transient tests were conducted on the heat pipe element. Details of the heat pipe development and test procedures are presented.

Keddy, E.↗

Capillary-Pumped Heat-Transfer Loop

New type of capillary-pumped heat-transfer loop primes itself at startup. Removes substantial quantities of heat like that generated by people and equipment in rooms and vehicles. Creates continuous path for its working fluid; both vapor and liquid move in same direction. Key element in operation of loop is formation of slugs of liquid, condensed from vapor and moved along loop by vapor bubbles before and after it. Both evaporator and condenser contain axial arteries carrying water. Heat entering evaporator from heat source provides energy for transport of fluid and heat. Dimensions in inches.

Source record↗

The design of a multimegawatt heat pipe radiator for an inertial fusion rocket powered manned Mars mission

A system of heat pipe radiators has been designed to provide waste heat rejection for an inertial fusion powered spacecraft capable of manned missions to other planets. The radiators are arrays of unfinned, arterial heat pipes operating at 1500 and 900 K. Liquid metal coolant carries up to 8000 MW of waste heat through feed pipes from on-board components (laser drivers and coil shield). The radiators do not rely on armor for protection from micrometeoroid penetration. An armored radiator design for this application with a 99 percent survivability would have a specific mass of 0.06 to 0.11 kg/kW at 1500 K. Instead, a segmentation of heat pipes is used, and bumpers are utilized to protect the feed pipes. This design reduces the specific mass to 0.015 to 0.04 kg/kW for the coil shield radiator (1500 K) and 0.06 to 0.12 kg/kW for the laser driver radiator (900 K).

Murray, K. A.↗