Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “analytical sensitivity analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Performance Analysis of Garbage Collection and Dynamic Reordering in a Lisp System

Generation based garbage collection and dynamic reordering of objects are two techniques for improving the efficiency of memory management in Lisp and similar dynamic language systems. An analysis of the effect of generation configuration is presented, focusing on the effect of a number of generations and generation capabilities. Analytic timing and survival models are used to represent garbage collection runtime and to derive structural results on its behavior. The survival model provides bounds on the age of objects surviving a garbage collection at a particular level. Empirical results show that execution time is most sensitive to the capacity of the youngest generation. A technique called scanning for transport statistics, for evaluating the effectiveness of reordering independent of main memory size, is presented.

Llames, Rene Lim↗

Documentation for a Structural Optimization Procedure Developed Using the Engineering Analysis Language (EAL)

This report describes a structural optimization procedure developed for use with the Engineering Analysis Language (EAL) finite element analysis system. The procedure is written primarily in the EAL command language. Three external processors which are written in FORTRAN generate equivalent stiffnesses and evaluate stress and local buckling constraints for the sections. Several built-up structural sections were coded into the design procedures. These structural sections were selected for use in aircraft design, but are suitable for other applications. Sensitivity calculations use the semi-analytic method, and an extensive effort has been made to increase the execution speed and reduce the storage requirements. There is also an approximate sensitivity update method included which can significantly reduce computational time. The optimization is performed by an implementation of the MINOS V5.4 linear programming routine in a sequential liner programming procedure.

Martin, Carl J., Jr.↗

Quantitative Electron Probe Microanalysis: State of the Art

Quantitative electron-probe microanalysis (EPMA) has improved due to better instrument design and X-ray correction methods. Design improvement of the electron column and X-ray spectrometer has resulted in measurement precision that exceeds analytical accuracy. Wavelength-dispersive spectrometer (WDS) have layered-dispersive diffraction crystals with improved light-element sensitivity. Newer energy-dispersive spectrometers (EDS) have Si-drift detector elements, thin window designs, and digital processing electronics with X-ray throughput approaching that of WDS Systems. Using these systems, digital X-ray mapping coupled with spectrum imaging is a powerful compositional mapping tool. Improvements in analytical accuracy are due to better X-ray correction algorithms, mass absorption coefficient data sets,and analysis method for complex geometries. ZAF algorithms have ban superceded by Phi(pz) algorithms that better model the depth distribution of primary X-ray production. Complex thin film and particle geometries are treated using Phi(pz) algorithms, end results agree well with Monte Carlo simulations. For geological materials, X-ray absorption dominates the corretions end depends on the accuracy of mass absorption coefficient (MAC) data sets. However, few MACs have been experimentally measured, and the use of fitted coefficients continues due to general success of the analytical technique. A polynomial formulation of the Bence-Albec alpha-factor technique, calibrated using Phi(pz) algorithms, is used to critically evaluate accuracy issues and can be also be used for high 2% relative and is limited by measurement precision for ideal cases, but for many elements the analytical accuracy is unproven. The EPMA technique has improved to the point where it is frequently used instead of the petrogaphic microscope for reconnaissance work. Examples of stagnant research areas are: WDS detector design characterization of calibration standards, and the need for more complete treatment of the continuum X-ray fluorescence correction.

Carpernter, P. K.↗

JPL Thermal Design Modeling Philosophy and NASA-STD-7009 Standard for Models and Simulations - A Case Study

The Standard JPL thermal engineering practice prescribes worst-case methodologies for design. In this process, environmental and key uncertain thermal parameters (e.g., thermal blanket performance, interface conductance, optical properties) are stacked in a worst case fashion to yield the most hot- or cold-biased temperature. Thus, these simulations would represent the upper and lower bounds. This, effectively, represents JPL thermal design margin philosophy. Uncertainty in the margins and the absolute temperatures is usually estimated by sensitivity analyses and/or by comparing the worst-case results with "expected" results. Applicability of the analytical model for specific design purposes along with any temperature requirement violations are documented in peer and project design review material. In 2008, NASA released NASA-STD-7009, Standard for Models and Simulations. The scope of this standard covers the development and maintenance of models, the operation of simulations, the analysis of the results, training, recommended practices, the assessment of the Modeling and Simulation (M&S) credibility, and the reporting of the M&S results. The Mars Exploration Rover (MER) project thermal control system M&S activity was chosen as a case study determining whether JPL practice is in line with the standard and to identify areas of non-compliance. This paper summarizes the results and makes recommendations regarding the application of this standard to JPL thermal M&S practices.

thermal blanket performance↗

Analytical modeling of the evolution of the nonlinearity parameter of sensitized stainless steel

Austenitic stainless steels are subject to the precipitation of chromium carbides (M 23 C 6 ) during exposure to high temperatures, causing these alloys to be susceptible to intergranular corrosion due to chromium depletion along grain boundaries. The acoustic nonlinearity parameter, β, shows sensitivity to the formation of carbides in these alloys. The Thermo-Calc TC-PRISMA module was used to model the nucleation and growth of grain boundary M 23 C 6 carbides. The model was verified with scanning transmission electron microscopy analysis that allowed measurements of the grain boundary precipitates. The paper introduces a reduced-order model of the acoustic nonlinearity based on the formation of misfit dislocations at the interface of the grain boundary precipitate and matrix to explain the change in β during isothermal aging. Furthermore, a direct relationship between the radius of the M 23 C 6 grain boundary carbides and β was observed and verified with nonlinear ultrasound measurements on 304L and 316L stainless steels.

36 MATERIALS SCIENCE↗

Experimental and modeling study of C2–C4 alcohol autoignition at intermediate temperature conditions

C2–C4 alcohols are advantageous blendstocks identified by many research groups, including the U.S. Department of Energy Co-Optima Initiative, towards enabling efficient, boosted Spark-Ignition (SI) engines. Their use in advanced engine applications requires a comprehensive understanding of their intermediate-temperature autoignition behavior. This work reports an experimental and modeling study covering their fundamental autoignition characteristics in a twin-piston rapid compression machine at pressures of 20 and 40 bar, intermediate temperatures from 750 to 980 K, and two fuel loading conditions representative of boosted SI engines. Direct comparison between these alcohols is made, where the order of reactivity is established across different thermodynamic and fuel loading conditions. Changes in preliminary exothermicity (or intermediate-temperature heat release) displayed in single-stage autoignition across different alcohols and conditions are also quantified. This provides insight into fuel-to-fuel differences, and how these could affect advanced combustion concepts such as spark-assisted compression ignition. Kinetic models are used to simulate the experiments, and reasonable agreement is obtained. Furthermore, the sensitivity analysis results demonstrate the importance of accurately capturing the autoignition kinetics, particularly H-abstraction reactions on the parent fuels by OH and HO 2 , and the branching ratio associated with these.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hard x-rays nanoscale fluorescence imaging of Earth and Planetary science samples

A hard x-ray nanoprobe has been implemented at the synchrotron in Grenoble, France, allowing nondestructive trace element imaging of thick samples. Its advantages are nanometer spatial resolution on samples of several tens of micrometer, very high flux, and achromaticity. Nanometer imaging of a cometary grain from the NASA Stardust mission shows the sensitivity and resolution gains obtained while radically changing our understanding of the composition of heterogeneous samples. The probe opens unique possibilities in the study of minute, fragile samples fundamental to the earth and planetary sciences, which until now were out of the reach of direct analytical methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single atom catalysts on amorphous supports: A quenched disorder perspective

Phenomenological models that invoke catalyst sites with different adsorption constants and rate constants are well-established, but computational and experimental methods are just beginning to provide atomically resolved details about amorphous surfaces and their active sites. This letter develops a statistical transformation from the quenched disorder distribution of site structures to the distribution of activation energies for sites on amorphous supports. We show that the overall kinetics are highly sensitive to the precise nature of the low energy tail in the activation energy distribution. Our analysis motivates further development of systematic methods to identify and understand the most reactive members of the active site distribution.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Geometric Structure Determination of N694C Lipoxygenase: a Comparative Near-Edge X-Ray Absorption Spectroscopy And Extended X-Ray Absorption Fine Structure Study

The mononuclear nonheme iron active site of N694C soybean lipoxygenase (sLO1) has been investigated in the resting ferrous form using a combination of Fe-K-pre-edge, near-edge (using the minuit X-ray absorption near-edge full multiple-scattering approach), and extended X-ray absorption fine structure (EXAFS) methods. The results indicate that the active site is six-coordinate (6C) with a large perturbation in the first-shell bond distances in comparison to the more ordered octahedral site in wild-type sLO1. Upon mutation of the asparigine to cystiene, the short Fe-O interaction with asparigine is replaced by a weak Fe-(H{sub 2}O), which leads to a distorted 6C site with an effective 5C ligand field. In addition, it is shown that near-edge multiple scattering analysis can give important three-dimensional structural information, which usually cannot be accessed using EXAFS analysis. It is further shown that, relative to EXAFS, near-edge analysis is more sensitive to partial coordination numbers and can be potentially used as a tool for structure determination in a mixture of chemical species.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fourier plane colorimetric sensing using broadband imaging of surface plasmons and application to biosensing

We demonstrate an optical technique for refractive index and thickness sensing of sub-wavelength-thick dielectric analytes. The technique utilizes the broadband, multimode, directional leakage radiation arising from the excitation of hybrid mode surface plasmons (SP) on low aspect ratio periodic plasmonic substrates with period ≈λ. The approach requires relaxed fabrication tolerances compared to extra ordinary transmission-based sensing techniques, wherein minor shifts in the fabricated dimensions result in a very large change from the designed resonant wavelength. We show that refractive index perturbations due to about 10-nm-thick dielectric can be captured optically by the usage of carefully designed plasmonic substrates, a halogen lamp source, free-space optical components, polarizers, and a low-end, consumer-grade charge coupled device camera. The plasmonic substrates were designed for converting the signature of hybrid mode SP excitation into a transmission peak by utilizing a thin homogeneous metal layer sandwiched between the periodic plasmonic structures and the substrate. The resonance is highly sensitive to the refractive index and thickness of the analyte superstrate. The excitation of hybrid mode SP results in a polarization rotation of 90° of the leaked radiation at resonant wavelength. In order to eliminate the problem of image registration (i.e., placing the same feature in the same pixel of the image, for comparison before and after a change in refractive index) for sensing, we perform the color analysis in the Fourier plane. The change in color of the bright emitted spot with highest momentum, corresponding to the leakage of fundamental SP mode, was used to measure the changes in refractive index, whereas the number and color of spots of lower momenta, corresponding to higher-order Fabry Perot modes, was used to measure the variation in thickness. We further show that the Fourier plane analysis can also be used to sense the index of thicker dielectrics, where real plane image analysis may fail to sense index perturbations, simply due to superposition of different modes in the real plane images of such substrates. Control experiments and analysis revealed a refractive index resolution of 10{sup –5} RIU. The results were correlated with simulations to establish the physical origin of the change in the fundamental mode and higher-order modes due to the refractive index and thickness of analyte. As a demonstration of an application and to test the limits of sensing, the substrates were used to image the surface functionalization using 2-nm-thick 11-mercaptoundecanoic acid and immobilization of 7-nm-thick mouse anti-human IgG antibody. In biological systems, where a priori knowledge about a process step is available, where accurate chemical composition testing is not necessary or possible, the presented method could be used to study the surface changes using a label-free sensing mechanism.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A simple novel device for air sampling by electrokinetic capture

A variety of different sampling devices are currently available to acquire air samples for the study of the microbiome of the air. All have a degree of technical complexity that limits deployment. Here, we evaluate the use of a novel device, which has no technical complexity and is easily deployable. An air-cleaning device powered by electrokinetic propulsion has been adapted to provide a universal method for collecting samples of the aerobiome. Plasma-induced charge in aerosol particles causes propulsion to and capture on a counter-electrode. The flow of ions creates net bulk airflow, with no moving parts. A device and electrode assembly have been re-designed from air-cleaning technology to provide an average air flow of 120 lpm. This compares favorably with current air sampling devices based on physical air pumping. Capture efficiency was determined by comparison with a 0.4 μm polycarbonate reference filter, using fluorescent latex particles in a controlled environment chamber. Performance was compared with the same reference filter method in field studies in three different environments. For 23 common fungal species by quantitative polymerase chain reaction (qPCR), there was 100 % sensitivity and apparent specificity of 87%, with the reference filter taken as “gold standard.” Further, bacterial analysis of 16S RNA by amplicon sequencing showed equivalent community structure captured by the electrokinetic device and the reference filter. Unlike other current air sampling methods, capture of particles is determined by charge and so is not controlled by particle mass. We analyzed particle sizes captured from air, without regard to specific analyte by atomic force microscopy: particles at least as low as 100 nM could be captured from ambient air. This work introduces a very simple plug-and-play device that can sample air at a high-volume flow rate with no moving parts and collect particles down to the sub-micron range. In conclusion, the performance of the device is substantially equivalent to capture by pumping through a filter for microbiome analysis by quantitative PCR and amplicon sequencing.

47 OTHER INSTRUMENTATION↗

Treatment of body forces in boundary element design sensitivity analysis

The inclusion of body forces has received a good deal of attention in boundary element research. The consideration of such forces is essential in the desgin of high performance components such as fan and turbine disks in a gas turbine engine. Due to their critical performance requirements, optimal shapes are often desired for these components. The boundary element method (BEM) offers the possibility of being an efficient method for such iterative analysis as shape optimization. The implicit-differentiation of the boundary integral equations is performed to obtain the sensitivity equations. The body forces are accounted for by either the particular integrals for uniform body forces or by a surface integration for non-uniform body forces. The corresponding sensitivity equations for both these cases are presented. The validity of present formulations is established through a close agreement with exact analytical results.

Saigal, Sunil↗

Design and Evaluation of a Tethered, Open Port Sampling Interface for Liquid Extraction-Mass Spectrometry Chemical Analysis

Presented in this work is a tethered, liquid-extraction-sampling interface designed for the mass spectrometric surface sampling/analysis of 3D objects. The tethered, open port sampling interface (TOPSI) incorporates a vacuum line between the sampling probe and ionization source, which enables the ability for an extended, tethered sample transfer line. Herein, several designs of the hand-held TOPSI are presented and evaluated on the basis of the analytical metrics of analyte transport time, peak width, and analyte sensitivity. The best analytical metrics were obtained with capillary flow resistances arranged in a particular order and the vacuum region set at 6.2 kPa. This TOPSI design incorporated a transfer capillary 1 m in length, while retaining a fast analyte transport time (12 s), short signal peak width (5 s baseline-to-baseline), and high analyte signal at 90% of that obtained with a regular open port sampling interface (OPSI). The hand-held TOPSI was demonstrated for the characterization of extracted small molecules and metabolites from the surface of mint and rosemary leaves.

47 OTHER INSTRUMENTATION↗

Self-consistent modeling of electrochemical strain microscopy of solid electrolytes

Electrochemical strain microscopy (ESM) employs a strong electromechanical coupling in solid ionic conductors to map ionic transport and electrochemical processes with nanometer-scale spatial resolution. To elucidate the mechanisms of the ESM image formation, we performed self-consistent numerical modeling of the electromechanical response in solid electrolytes under the probe tip in a linear, small-signal regime using the Boltzmann–Planck–Nernst–Einstein theory and Vegard's law while taking account of the electromigration and diffusion. We identified the characteristic time scales involved in the formation of the ESM response and found that the dynamics of the charge carriers in the tip-electrolyte system with blocking interfaces can be described as charging of the diffuse layer at the tip-electrolyte interface through the tip contact spreading resistance. At the high frequencies used in the detection regime, the distribution of the charge carriers under the tip is governed by evanescent concentration waves generated at the tip-electrolyte interface. The ion drift length in the electric field produced by the tip determines the ESM response at high frequencies, which follows a 1/f asymptotic law. The electronic conductivity, as well as the electron transport through the electrode-electrolyte interface, do not have a significant effect on the ESM signal in the detection regime. The results indicate, however, that for typical solid electrolytes at room temperature, the ESM response originates at and contains information about the very surface layer of a sample, and the properties of the one-unit-cell-thick surface layer may significantly contribute to the ESM response, implying a high surface sensitivity and a high lateral resolution of the technique. On the other hand, it follows that a rigorous analysis of the ESM signals requires techniques that account for the discrete nature of a solid.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A study on the statistical significance of mutual information between morphology of a galaxy and its large-scale environment

ABSTRACT A non-zero mutual information between morphology of a galaxy and its large-scale environment is known to exist in Sloan Digital Sky Survey (SDSS) upto a few tens of Mpc. It is important to test the statistical significance of these mutual information if any. We propose three different methods to test the statistical significance of these non-zero mutual information and apply them to SDSS and Millennium run simulation. We randomize the morphological information of SDSS galaxies without affecting their spatial distribution and compare the mutual information in the original and randomized data sets. We also divide the galaxy distribution into smaller subcubes and randomly shuffle them many times keeping the morphological information of galaxies intact. We compare the mutual information in the original SDSS data and its shuffled realizations for different shuffling lengths. Using a t-test, we find that a small but statistically significant (at $99.9{{\ \rm per\ cent}}$ confidence level) mutual information between morphology and environment exists upto the entire length-scale probed. We also conduct another experiment using mock data sets from a semi-analytic galaxy catalogue where we assign morphology to galaxies in a controlled manner based on the density at their locations. The experiment clearly demonstrates that mutual information can effectively capture the physical correlations between morphology and environment. Our analysis suggests that physical association between morphology and environment may extend to much larger length-scales than currently believed, and the information theoretic framework presented here can serve as a sensitive and useful probe of the assembly bias and large-scale environmental dependence of galaxy properties.

Sarkar, Suman↗

Transition of Iodine Analysis to Accelerator Mass Spectrometry

The goal of the project, New Paradigms for Isotope Ratio Mass Spectrometry: Raising the Scientific Profile and Improved Performance for Accelerator Mass Spectrometry (AMS) and Thermal Ionization Mass Spectrometry (TIMS), is to ensure that the ongoing isotope ratio determination capability within the U.S. Department of Energy complex is the world’s best for application to nonproliferation. This report spells out the progress of Task 4, Transition of TIMS to AMS for Iodine Analysis, of the larger project. The subtasks under Task 4 and the accomplishments throughout the three year project life cycle are presented in this report. Progress was made in optimization of chemical extraction, determination of a detection limit for 127Iodine, production of standard materials for AMS analysis quality assurance, facilitation of knowledge exchange with respect to analyzing iodine on an AMS, cross comparison with a world-leading AMS laboratory, supercritical fluid extraction of iodine for AMS analysis and electrodeposition of seawater as a direct method of preparation for iodine analysis by AMS--all with the goal of minimizing the time required to stand up an AMS capability for iodine analysis of exposed air filters at INL. An effective extraction method has been developed and demonstrated for iodine analysis of exposed air filters. Innovative techniques to accomplish the cathode preparation for AMS analysis were developed and demonstrated and published. The known gap of a lack of available materials for reference standards in the analysis of iodine by AMS was filled by the preparation of homogenous materials that were calibrated against NIST materials. A minimum limit on the amount of abundant isotope in a sample was determined for AMS analysis. The knowledge exchange occurred with fantastic success. Scientists engaged the international AMS community at conferences, as well as in their laboratories for collaborative work. The supercritical fluid extraction work has positive data, but is not a replacement for leaching yet. The added seawater work has led to a good method and a possible publication. The focus of this project was to minimize the time to stand up the AMS capability, by having all the preparation and supporting functions worked out ahead of the instrument arrival. Due to all the preparatory work and its success, the instrument was delivered and turned over to the INL in February 2015. Since then, INL scientists have been successfully vetting the capabilities and accomplishing their own measurements that agree well with the leading laboratories of the world for iodine analysis by AMS. Initially, all AMS data was gathered on other laboratories instruments, but during the last six months data for this project has come from INL’s AMS.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fiber Bragg Grating Dilatometry in Extreme Magnetic Field and Cryogenic Conditions

In this work, we review single mode SiO 2 fiber Bragg grating techniques for dilatometry studies of small single-crystalline samples in the extreme environments of very high, continuous, and pulsed magnetic fields of up to 150 T and at cryogenic temperatures down to <1 K. Distinct millimeter-long materials are measured as part of the technique development, including metallic, insulating, and radioactive compounds. Experimental strategies are discussed for the observation and analysis of the related thermal expansion and magnetostriction of materials, which can achieve a strain sensitivity (ΔL/L) as low as a few parts in one hundred million (≈10 -8 ). The impact of experimental artifacts, such as those originating in the temperature dependence of the fiber’s index of diffraction, light polarization rotation in magnetic fields, and reduced strain transfer from millimeter-long specimens, is analyzed quantitatively using analytic models available in the literature. We compare the experimental results with model predictions in the small-sample limit, and discuss the uncovered discrepancies.

36 MATERIALS SCIENCE↗

A Modelling Framework for Understanding the Impacts of Radioactive and Chemo-toxic Waste Disposals - 18199

In order to assess the compliance of a radioactive waste disposal facility against regulatory requirements, it is usual to develop a numerical model that provides estimates of quantities such as effective dose, radiological risk and environmental concentrations at times in the future after disposal of the wastes. An important aspect of a safety case based on the results of the numerical assessment model is to develop understanding and confidence in the results. This understanding includes determining why the magnitudes of the results are as they are, determining the key controlling parameters on the model outputs, providing confidence that the model outputs are credible, providing an alternative and complementary modelling approach, undertaking sensitivity analyses and facilitating communication of the safety case results with stakeholders. In this paper we present a modelling approach that addresses these issues for a wide range of disposal concepts. The approach captures the key processes that affect contaminant migration and transport, and uses analytical solutions to provide insight and understanding about the behaviour of a disposal system. The approach has been tested against a wide range of concepts for LLW, ILW, HLW and SF. In all cases, agreement with the results from numerical assessment models is found to be very good, with estimates of peak radiological risk and other metrics within a factor of two or better, compared with those from numerical assessment models. This agreement is achieved for assessment results that can potentially span many orders of magnitude. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗