Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Volume measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

UAM Instrument Flight Procedure Design and Evaluation in the Joby Flight Simulator

NASA’s Advanced Air Mobility (AAM) National Campaign (NC) partnered with Joby Aviation to test and evaluate different developmental candidate Urban Air Mobility (UAM) Instrument Flight Procedure (IFP) designs including new departure, enroute, approach and missed approach architectures using Joby’s high-fidelity engineering aircraft simulator. In conjunction with the simulator testing, this effort also evaluated related aspects such as charting, coding, and adherence to flight planning criteria. The test objectives were to assess the safety, efficiency, passenger comfort and noise of the different variations of the developmental IFPs. Safety-related measures include clearance from terrain and vertical obstructions, procedure flyability, and flight path conformance. Efficiency-related measures included time required, airspace volume required, and battery energy required. Passenger comfort and ride quality measures include roll/pitch angles, roll/pitch attitude change rates, and airspeeds prior to aggressive maneuvers, subjective pilot/passenger responses and acceleration forces. The noise impacts of the different IFPs will be interpolated/extrapolated using data from the simulator fed into a separate Joby acoustic software-based tool. Overall, several tradeoffs were identified and characterized between the different variations of the developmental IFP profiles. No single version of the developmental IFP structure scored highest across all measures listed above; rather, different IFP variations proved optimal for different measures, confirming that the best IFP depends on which specific measures are prioritized for a given aircraft, location and operation.

National Campaign↗

Improved Devices for Collecting Sweat for Chemical Analysis

Improved devices have been proposed for collecting sweat for biochemical analysis especially for determination of the concentration of Ca2+ ions in sweat as a measure of loss of Ca from bones. Unlike commercially available sweat-collection patches used previously in monitoring osteoporosis and in qualitative screening for some drugs, the proposed devices would not allow evaporation of the volatile chemical components (mostly water) of sweat. Moreover, the proposed devices would be designed to enable determination of the volumes of collected sweat. From these volumes and the quantities of Ca2+ and/or other analytes as determined by other means summarized below, one could determine the concentrations of the analytes in sweat. A device according to the proposal would be flexible and would be worn like a commercial sweat-collection patch. It would be made of molded polydimethylsiloxane (silicone rubber) or other suitable material having properties that, for the purpose of analyzing sweat, are similar to those of glass. The die for molding the silicone rubber would be fabricated by a combination of lithography and electroplating. The die would reproducibly form, in the silicone rubber, a precisely defined number of capillary channels per unit area, each channel having a precisely defined volume. Optionally, electrodes for measuring the Ca2+ content of the sweat could be incorporated into the device. The volume of sweat collected in the capillary channels of the device would be determined from (1) the amount of light or radio waves of a given wavelength absorbed by the device and (2) the known geometry of the array of capillary channels. Then, in one of two options, centrifugation would be performed to move the sweat from the capillary tubes to the region containing the electrodes, which would be used to measure the Ca2+ content by a standard technique. In the other option, centrifugation would be performed to remove the sweat from the device to make the sweat available to other analytical instruments for measuring concentrations of substances other than Ca2+.

Feeback, Daniel L.↗

Phase Doppler Interferometry for Efficient Cloud Drop Size Distribution, Number Density, and LWC Measurements

Threats to aviation safety as a result of super-cooled large drops (SLD) has been addressed by the FAA rules change (14 CFR Part 25) with the additional icing certification requirement. SLD clouds often consist of bi-modal drop size spectra leading to significant problems in simulating and characterizing these conditions in situ and in icing wind tunnels. Legacy instrumentation for measuring drop size distributions and liquid water content are challenged under these conditions. The large size range measurement problem is addressed with the development of the Phase Doppler Interferometer, Flight Probe Dual-Range (PDI FPDR). The method is described in this report along with the measurement capabilities including the dynamic measurement range and overall working size range. The PDI instrument bases drop size measurements on the light wavelength as the measurement length scale. The light wavelength is a much more robust scale, especially as compared to the light scattering intensity. Additionally, methods for accurately characterizing the sample volume in situ based on measured drop velocity and transit time are reviewed, given the importance of this parameter for merging results and measuring LWC. Droplet coincidence in the sample volume can be problematic so this condition is treated with an innovative signal parsing approach. Measurement examples acquired in the NASA IRT are provided. Measurements of LWC showed good agreement with the Artium Particle Imaging (PI) instrument but diverged from the tunnel calibration results for larger MVD values.

42 ENGINEERING↗

Improved Devices for Collecting Sweat for Chemical Analysis

Improved devices have been proposed for collecting sweat for biochemical analysis - especially for determination of the concentration of Ca2+ ions in sweat as a measure of loss of Ca from bones. Unlike commercially available sweat-collection patches used previously in monitoring osteoporosis and in qualitative screening for some drugs, the proposed devices would not allow evaporation of the volatile chemical components (mostly water) of sweat. Moreover, the proposed devices would be designed to enable determination of the volumes of collected sweat. From these volumes and the quantities of Ca(2+) and/or other analytes as determined by other means summarized below, one could determine the concentrations of the analytes in sweat. A device according to the proposal would be flexible and would be worn like a commercial sweat-collection patch. It would be made of molded polydimethylsiloxane (silicone rubber) or other suitable material having properties that, for the purpose of analyzing sweat, are similar to those of glass. The die for molding the silicone rubber would be fabricated by a combination of lithography and electroplating. The die would reproducibly form, in the silicone rubber, a precisely defined number of capillary channels per unit area, each channel having a precisely defined volume. Optionally, electrodes for measuring the Ca(2+) content of the sweat could be incorporated into the device. The volume of sweat collected in the capillary channels of the device would be determined from (1) the amount of light or radio waves of a given wavelength absorbed by the device and (2) the known geometry of the array of capillary channels. Then, in one of two options, centrifugation would be performed to move the sweat from the capillary tubes to the region containing the electrodes, which would be used to measure the Ca(2+) content by a standard technique. In the other option, centrifugation would be performed to remove the sweat from the device to make the sweat available to other analytical instruments for measuring concentrations of substances other than Ca(2+).

Feedback, Daniel L.↗

CARS system for turbulent flame measurements

Simultaneous nitrogen number density and rotational-vibrational temperatures were measured in a turbulent diffusion flame with a Coherent Anti-Stokes Raman Scattering (CARS) instrument. The fuel jet was diluted with nitrogen (20 percent by volume) to allow temperature measurements across the entire jet mixing region. These measurements were compared with fluid dynamics computations. The CARS system incorporated a neodymium YAG laser, an intensified silicon photodiode array detector, and unique dynamic range enhancement methods. Theoretical calculations were based on a parabolic Navier-Stokes computer code. The comparison of these techniques will aid their development in the study of complex flowfields.

Antcliff, R. R.↗

Modeling Rate Dependent Volume Change in Porous Electrodes in Lithium-Ion Batteries

Automotive manufacturers are working to improve individual cell, module, and overall pack design by increasing the performance, range, and durability, while reducing cost. One key piece to consider during the design process is the active material volume change, its linkage to the particle, electrode, and cell level volume changes, and the interplay with structural components in the rechargeable energy storage system. As the time from initial design to manufacture of electric vehicles decreases, design work needs to move to the virtual domain; therefore, a need for coupled electrochemical-mechanical models that take into account the active material volume change and the rate dependence of this volume change need to be considered. In this study, we illustrated the applicability of a coupled electrochemical-mechanical battery model considering multiple representative particles to capture experimentally measured rate dependent reversible volume change at the cell level through the use of an electrochemical-mechanical battery model that couples the particle, electrode, and cell level volume changes. By employing this coupled approach, the importance of considering multiple active material particle sizes representative of the distribution is demonstrated. The non-uniformity in utilization between two different size particles as well as the significant spatial non-uniformity in the radial direction of the larger particles is the primary driver of the rate dependent characteristics of the volume change at the electrode and cell level.

Electrochemistry↗

Radiography. Volume 2 - Radiation safety

Radiation measurement techniques and devices, occupational and other dosages, personnel protection, and other aspects of radiation safety - programmed text on nondestructive tests

Source record↗

The influence of inhomogeneity of the reflectivity distribution on the accuracy of its measurement

The influence of pulse volume dimensions on the accuracy of reflectivity from various clouds is considered. It is shown that due to the spatial averaging and the inhomogeneities of the clouds, the dependence frequently breaks down, which is a cause of lower values of the spatial distribution estimate. Values of the corrections calculated for various conditions are presented.

Salman, Y. M.↗

Blood volume changes

Red cell mass measurements on Skylab crewmembers revealed a statistically significant decrease in circulating red cells. Low reticulocyte counts at crewmember recovery indicated increased splenic removal of reticulum or decreased bone marrow production rates. After the initial loss there is at least a 30-day delay before red cell mass begins to reconstitute itself.

Johnson, P. C.↗

Carbon-14 ages of Antarctic meteorites with accelerator and small-volume counting techniques

C-14 measurements were made on six Yamato and Victoria Land meteorites using tandem accelerator mass spectroscopy. The studies brought to 27 the number of Antarctic meteorites that have been examined for terrestrial aging. Details of the spectroscopic method are provided, along with the results in combinations with the data from the other 21 meteorites. It is found that the Yamato meteorites are younger than those found at Allan Hills, implying that two mechanisms may exist for the abundant Antarctic meteorites: exposure where falling due to a paucity of ice, and transport and exposure by sublimating ice.

Jull, A. J. T.↗

Method of high-precision microsampled blood and plasma mass densitometry

The reliability of the mechanical oscillator technique for blood and plasma density measurements on samples of volumes less than 0.1 ml is examined, and a precision of 0.001 g/l is found if plasma-isodensic heparin solution and siliconized densitometers are employed. Sources of measurement errors in the density determinations include storage of plasma samples, inhomogeneity of blood samples, and density reading before adequate temperature equilibration. In tests of plasma sample storage, the best reproducibility was obtained with samples kept at 4 C. Linear correlations were found between plasma density and plasma protein concentration, blood density and blood hemoglobin concentration, and erythrocyte density and MCHC.

Hinghofer-Szalkay, H.↗

Predictions of vertical uplift caused by changing polar ice volumes on a viscoelastic earth

Measurements of crustal uplift from bedrock around the edges of Antarctica or Greenland could help constrain the mass balance of those ice caps. Present-day changes in ice could cause vertical displacement rates of several mm/yr around Antarctica and up to 10-15 mm/yr around Greenland. Horizontal displacement rates are likely to be about 1/3 the vertical rates. The viscoelastic response of the earth to past changes in ice could cause uplift rates that are several times larger. By measuring both gravity and vertical displacements, it is possible to remove the viscoelastic effects, so that the observations can be used to constrain present-day thickness changes.

Wahr, John↗

On-chip polarimetry for high-throughput screening of nanoliter and smaller sample volumes

A polarimetry technique for measuring optical activity that is particularly suited for high throughput screening employs a chip or substrate (22) having one or more microfluidic channels (26) formed therein. A polarized laser beam (14) is directed onto optically active samples that are disposed in the channels. The incident laser beam interacts with the optically active molecules in the sample, which slightly alter the polarization of the laser beam as it passes multiple times through the sample. Interference fringe patterns (28) are generated by the interaction of the laser beam with the sample and the channel walls. A photodetector (34) is positioned to receive the interference fringe patterns and generate an output signal that is input to a computer or other analyzer (38) for analyzing the signal and determining the rotation of plane polarized light by optically active material in the channel from polarization rotation calculations.

Bornhop, Darryl J.↗

Measurements and Modeling of Soot Formation and Radiation in Microgravity Jet Diffusion Flames

This is a computational and experimental study for soot formation and radiative heat transfer in jet diffusion flames under normal gravity (1-g) and microgravity (0-g) conditions. Instantaneous soot volume fraction maps are measured using a full-field imaging absorption technique developed by the authors. A compact, self-contained drop rig is used for microgravity experiments in the 2.2-second drop tower facility at NASA Lewis Research Center. On modeling, we have coupled flame structure and soot formation models with detailed radiation transfer calculations. Favre-averaged boundary layer equations with a k-e-g turbulence model are used to predict the flow field, and a conserved scalar approach with an assumed Beta-pdf are used to predict gaseous species mole fraction. Scalar transport equations are used to describe soot volume fraction and number density distributions, with formation and oxidation terms modeled by one-step rate equations and thermophoretic effects included. An energy equation is included to couple flame structure and radiation analyses through iterations, neglecting turbulence-radiation interactions. The YIX solution for a finite cylindrical enclosure is used for radiative heat transfer calculations. The spectral absorption coefficient for soot aggregates is calculated from the Rayleigh solution using complex refractive index data from a Drude- Lorentz model. The exponential-wide-band model is used to calculate the spectral absorption coefficient for H20 and C02. It is shown that when compared to results from true spectral integration, the Rosseland mean absorption coefficient can provide reasonably accurate predictions for the type of flames studied. The soot formation model proposed by Moss, Syed, and Stewart seems to produce better fits to experimental data and more physically sound than the simpler model by Khan et al. Predicted soot volume fraction and temperature results agree well with published data for a normal gravity co-flow laminar flames and turbulent jet flames. Predicted soot volume fraction results also agree with our data for 1-g and 0-g laminar jet names as well as 1-g turbulent jet flames.

Ku, Jerry C.↗

Muscle Volume Increases Following 16 Weeks of Resistive Exercise Training with the Advanced Resistive Exercise Device (ARED) and Free Weights

Space flight-induced muscle atrophy, particularly in the postural and locomotorymuscles, may impair task performance during long-duration space missions and planetary exploration. High intensity free weight (FW) resistive exercise training has been shown to prevent atrophy during bed rest, a space flight analog. NASA developed the Advanced Resistive Exercise Device (ARED) to simulate the characteristics of FW exercise (i.e. constant mass, inertial force) and to be used as a countermeasure during International Space Station (ISS) missions. PURPOSE: To compare the efficacy of ARED and FW training to induce hypertrophy in specific muscle groups in ambulatory subjects prior to deploying ARED on the ISS. METHODS: Twenty untrained subjects were assigned to either the ARED (8 males, 3 females) or FW (6 males, 3 females) group and participated in a periodizedtraining protocol consisting of squat (SQ), heel raise (HR), and deadlift(DL) exercises 3 d wk-1 for 16 wks. SQ, HR, and DL muscle strength (1RM) was measured before, after 8 wks, and after 16 wks of training to prescribe exercise and measure strength changes. Muscle volume of the vastigroup (V), hamstring group (H), hip adductor group (ADD), medial gastrocnemius(MG), lateral gastrocnemius(LG), and deep posterior muscles including soleus(DP) was measured using MRI pre-and post-training. Consecutive cross-sectional images (8 mm slices with a 2 mm gap) were analyzed and summed. Anatomical references insured that the same muscle sections were analyzed pre-and post-training. Two-way repeated measures ANOVAs (p<0.05) were used to test for differences in muscle strength and volume between training devices. RESULTS: SQ, HR, and DL 1RM increased in both FW (SQ: 49+/-6%, HR: 12+/-2%, DL: 23+/-4%) and ARED (SQ: 31+/-4%, HR: 18+/-2%, DL: 23+/-3%) groups. Both groups increased muscle volume in the V (FW: 13+/-2%, ARED: 10+/-2%), H (FW: 3+/-1%, ARED: 3+/-1 %), ADD (FW: 15=/-2%, ARED: 10+/-1%), LG (FW: 7+/-2%, ARED: 4+/-1%), MG (FW: 7+/-2%, ARED: 5+/-2%), and DP (FW: 2+/-1%; ARED: 2+/-1%) after training. There were no between group differences in muscle strength or volume. CONCLUSIONS: The increase in muscle volume and strength following ARED training is not different than FW training. With the training effects similar to FW and a 600 lb load capacity, ARED likely will protect against muscle atrophy in microgravity.

Nash, R. E.↗

ComStock Measure Documentation: Fan Static Pressure Reset for Multizone Variable Air Volume Systems

This report assesses the potential for nationwide adoption of a duct static pressure reset in MZ VAV systems in appropriate applications. Building on the 3-year End-Use Load Profiles project to calibrate and validate the U.S. Department of Energy’s ResStock™ and ComStock™ models, this work produces national datasets that enable cities, states, utilities, and other stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses various data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual sub-hourly energy consumption of the commercial building stock across the United States. The “baseline” model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology of the baseline model is discussed in the ComStock Reference Documentation. The goal of this work is to develop energy efficiency and demand flexibility measures that cover market-ready technologies and study their mass-adoption impact on the baseline building stock. “Measures” refers to various “what-if” scenarios that can be applied to buildings. The results for the baseline and measure scenario simulations are published in public datasets that provide insights into building stock characteristics, operational behaviors, utility bill impacts, and annual and sub-hourly energy usage by fuel type and end use. This report describes the modeling methodology for a single ComStock measure scenario—Fan Static Pressure Reset for Multizone Variable Air Volume (VAV) Systems—and briefly introduces key results. The full public dataset can be accessed on the ComStock data lake or via the Data Viewer at comstock.nrel.gov. The public dataset enables users to create custom aggregations of results for their use case (e.g., filter to a specific county or building type).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Infrared measurements of atmospheric gases above Mauna Loa, Hawaii, in February 1987

The IR absorptions spectra of 13 minor and trace atmospheric gases, recorded by the NOAA's Geophysical Monitoring for Climate Change (GMCC) program station at Mauna Loa, Hawaii, for four days in February 1987, were analyzed to determine simultaneous total vertical column amounts for these gases. Comparisons with other data indicate that the NOAA GMCC surface volume mixing ratios are good measures of the mean volume mixing ratios of these gases in the troposphere and that Mauna Loa is a favorable site for IR monitoring of atmospheric gases. The ozone total columns deduced from the IR spectra agreed with the correlative Umkehr observations.

Rinsland, C. P.↗