Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Volume Constraint”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Analysis and Benchmarking of feature reduction for classification under computational constraints

Abstract Machine learning is most often expensive in terms of computational and memory costs due to training with large volumes of data. Current computational limitations of many computing systems motivate us to investigate practical approaches, such as feature selection and reduction, to reduce the time and memory costs while not sacrificing the accuracy of classification algorithms. In this work, we carefully review, analyze, and identify the feature reduction methods that have low costs/overheads in terms of time and memory. Then, we evaluate the identified reduction methods in terms of their impact on the accuracy, precision, time, and memory costs of traditional classification algorithms. Specifically, we focus on the least resource intensive feature reduction methods that are available in Scikit-Learn library. Since our goal is to identify the best performing low-cost reduction methods, we do not consider complex expensive reduction algorithms in this study. In our evaluation, we find that at quadratic-scale feature reduction, the classification algorithms achieve the best trade-off among competitive performance metrics. Results show that the overall training times are reduced 61%, the model sizes are reduced 6×, and accuracy scores increase 25% compared to the baselines on average with quadratic scale reduction.

97 MATHEMATICS AND COMPUTING↗

Analytical theory of mesoscopic Bose-Einstein condensation in an ideal gas

We find the universal structure and scaling of the Bose-Einstein condensation (BEC) statistics and thermodynamics (Gibbs free energy, average energy, heat capacity) for a mesoscopic canonical-ensemble ideal gas in a trap with an arbitrary number of atoms, any volume, and any temperature, including the whole critical region. We identify a universal constraint-cutoff mechanism that makes BEC fluctuations strongly non-Gaussian and is responsible for all unusual critical phenomena of the BEC phase transition in the ideal gas. The main result is an analytical solution to the problem of critical phenomena. It is derived by, first, calculating analytically the universal probability distribution of the noncondensate occupation, or a Landau function, and then using it for the analytical calculation of the universal functions for the particular physical quantities via the exact formulas which express the constraint-cutoff mechanism. We find asymptotics of that analytical solution as well as its simple analytical approximations which describe the universal structure of the critical region in terms of the parabolic cylinder or confluent hypergeometric functions. The obtained results for the order parameter, all higher-order moments of BEC fluctuations, and thermodynamic quantities perfectly match the known asymptotics outside the critical region for both low and high temperature limits. We suggest two- and three-level trap models of BEC and find their exact solutions in terms of the cutoff negative binomial distribution (which tends to the cutoff gamma distribution in the continuous limit) and the confluent hypergeometric distribution, respectively. Also, we present an exactly solvable cutoff Gaussian model of BEC in a degenerate interacting gas. All these exact solutions confirm the universality and constraint-cutoff origin of the strongly non-Gaussian BEC statistics. We introduce a regular refinement scheme for the condensate statistics approximations on the basis of the infrared universality of higher-order cumulants and the method of superposition and show how to model BEC statistics in the actual traps. In particular, we find that the three-level trap model with matching the first four or five cumulants is enough to yield remarkably accurate results for all interesting quantities in the whole critical region. We derive an exact multinomial expansion for the noncondensate occupation probability distribution and find its high-temperature asymptotics (Poisson distribution) and corrections to it. Finally, we demonstrate that the critical exponents and a few known terms of the Taylor expansion of the universal functions, which were calculated previously from fitting the finite-size simulations within the phenomenological renormalization-group theory, can be easily obtained from the presented full analytical solutions for the mesoscopic BEC as certain approximations in the close vicinity of the critical point.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Absence of a bulk signature of a charge density wave in hard x-ray measurements of UTe 2

The long-sought pair density wave (PDW) is an exotic phase of matter in which charge density wave (CDW) order is intertwined with the amplitude or phase of coexisting, superconducting order. Originally predicted to exist in copper-oxides, circumstantial evidence for PDW order now exists in a variety of materials. Recently, scanning tunneling microscopy (STM) studies have reported evidence for a three-component CDW at the surface of the heavy-fermion superconductor, UTe 2 , persisting below its superconducting transition temperature [Aishwarya et al., Nature 618, 928933 (2023); Gu et al., Nature 618, 921927 (2023); LaFleur et al., Nat. Commun. 15, 4456 (2024)]. Here, in this study, we use hard x-ray diffraction measurements on crystals of UTe 2 at 𝑇 = 1.9 and 12 K to search for a bulk signature of this CDW. Using STM measurements as a constraint, we calculate the expected locations of CDW superlattice peaks and sweep a large volume of reciprocal space in search of a signature. We fail to find any evidence for a CDW near any of the expected superlattice positions in many Brillouin zones. We estimate an upper bound on the CDW lattice distortion of 𝑢 max ≲ 4×10 −3 Å. Our results suggest that the CDW observed in STM is either purely electronic, somehow lacking a signature in the lattice, or is restricted to the material surface.

Kengle, Caitlin S.↗

SU-E-T-308: Dosimetric Comparison of SBRT VMAT Treatment Plans Generated for 6 MV, 6 MV FFF, and 10 MV FFF Photon Beams

Purpose: To assess differences in treatment plan quality between VMAT stereotactic body plans generated using the 6 MV, 6 MV FFF, and 10 MV FFF modalities available in our clinic. Plans for lung, spine, and other sites were compared to see if there is any advantage of one modality over the other. Methods: Treatment plans done for actual SBRT patients were selected. Groups of ten lung plans, five spine plans, and five plans from other sites were selected. New treatment plans were generated for each plan using the Varian Eclipse AAA algorithm. The constraints were kept the same as used in the actual plans, but the same version of software was used to generate plans for the three modalities. In addition, because there are natural variations in plans re-done with the same dose constraints, one of the lung plans was repeated ten times to assess those differences. Volumes of the 100%, 90%, 50%, 20% and 10% isodose surfaces were compared. Maximum dose two centimeters from the PTV were compared, as well as the volume of the 105% isodose surface outside of the PTV. In addition, the 20 Gray lung volume was compared for the lung plans. The values of these parameters were divided by the values for the 6 MV plans for comparison. Average and standard deviations were obtained for quantities in each group. The Student t test was done to determine if differences were seen at the 95% confidence level. Results: Comparison of the treatment plans showed no significant differences when assessing these volumes and doses. There were not any trends seen when comparing modalities as a function of PTV volume either. Conclusion: There is no obvious dosimetric advantage in selection of one modality over another for these types of SBRT plans.

60 APPLIED LIFE SCIENCES↗

SU-F-T-395: Evaluation of Best Dosimetry Achievable with VMAT and IMRT Treatment Techniques Targeting Borderline Resectable Pancreatic Cancer

Purpose: To determine from retrospective study the most appropriate technique for targeting small borderline operable pancreatic cancer surrounding blood vessels by evaluating the dosimetry and normal tissue sparing achievable using Volumetric Modulated Arc Therapy (VMAT) and Intensity Modulated Radiation Therapy (IMRT). Methods: Treatment plans from ten patients who have undergone treatment with a prescribed dose of 4950 cGy, at 275 cGy per fraction, were analyzed. All plans were replanned using Eclipse TPS (Varian Medical Systems, Palo Alto, CA) with complementary VMAT or IMRT techniques to obtain paired data sets for comparison. The coverage to at least 95% of the planned target volume (PTV) was normalized to receive 100% of the prescription dose. The normal tissue constraints followed the quantitative analysis of normal tissue effects in the clinic (QUANTEC) guidelines and the organs at risks (OARs) were liver, kidneys, spinal cord and bowel. The plan evaluation was based on conformity index (CI), homogeneity index (HI), uniformity index (UI), DVH parameters, and student’s-t statistics (2 tails). Results: The VMAT technique delivered less maximum dose to the right kidney, left kidney, total kidney, liver, spinal cord, and bowel by 9.3%, 5.9%, 6.7%, 3.9%, 15.1%, 3.9%, and 4.3%, respectively. The averaged V15 for the total kidney was 10.21% for IMRT and 7.29% for VMAT. The averaged V20 for the bowel was 19.89% for IMRT and 14.06% for VMAT. On average, the CI for IMRT was 1.20 and 1.16 for VMAT (p = 0.20). The HI was 0.08 for both techniques (p = 0.91) and UI was 1.05 and 1.06 for IMRT and VMAT respectively (p = 0.59). Conclusion: Both techniques achieve adequate PTV coverage. Although VMAT techniques show better normal tissue sparing from excessive dose, no significant differences were observed. Slight discrepancies may rise from different versions of calculation algorithms.

60 APPLIED LIFE SCIENCES↗

Design of Column Separation Processes for Recovery of Molybdenum from Dissolved High-Density LEU Target

The Global Threat Reduction Initiative (GTRI) Conversion Program develops technology necessary to convert civilian facilities that use high enriched uranium (HEU) to low enriched uranium (LEU) fuels and targets. The conversion from conventional HEU dispersion targets to LEU for 99Mo production requires approximately five times the uranium in a target to maintain the 99 Mo yield per target. Under GTRI, Argonne National Laboratory (Argonne) is developing two frontend options for the current processes to allow the use of LEU-foil targets. In both processes, the aim is to produce a product after the frontend that will be compatible with current purification operations and that will, with the same number of targets irradiated, provide the same or a higher yield of 99 Mo at the end of processing. The goal of the frontend process is to deliver a product solution that is of the same or higher Mo purity than the current solution and is of equal or better compatibility with current purification process. In the first frontend option, the LEU foil (contained in a thin [10–15 µm] Ni fission-recoil barrier is removed from the annular target and dissolved in nitric acid. In the dissolution, the uranium, nickel, and all fission and activation products are dissolved; the solution will be ~7 mM Mo and ~450 g-U/L, and the nitric-acid concentration after dissolution will be ~1 M. The volume of solution is assumed to be 500 mL and the pressure drop, ΔP, constraint of 0.8 atm is based on the use of a vacuum/gravity fluid transfer system. Therefore pressure loss is limited to <1 atm; hence a value of 0.8 is chosen.

Stepinski, D. C.↗

System analysis approach to deriving design criteria (Loads) for Space Shuttle and its payloads. Volume 2: Typical examples

The achievement of an optimized design from the system standpoint under the low cost, high risk constraints of the present day environment was analyzed. Space Shuttle illustrates the requirement for an analysis approach that considers all major disciplines (coupling between structures control, propulsion, thermal, aeroelastic, and performance), simultaneously. The Space Shuttle and certain payloads, Space Telescope and Spacelab, are examined. The requirements for system analysis approaches and criteria, including dynamic modeling requirements, test requirements, control requirements, and the resulting design verification approaches are illustrated. A survey of the problem, potential approaches available as solutions, implications for future systems, and projected technology development areas are addressed.

Ryan, R. S.↗

Highly ionized gas in the Galactic halo

We reexamine the values of electron density n(sub e) and gas pressure P/k in the interstellar medium (ISM) of the Galactic halo, as inferred from C IV emission and absorption lines and using current C IV atomic data. In a homogeneous model with 4.7 less than or equal to log T less than or equal to 5.3, the data are consistent with 0.01 less than or equal to n(sub e) less than or equal to 0.02/cu cm and 2200 less than or equal to P/k less than or equal to 3700/cu cm K, a factor of 2-3 higher than advocated by Martin & Bowyer (1990) and comparable to the thermal pressure in the disk. If some of the C IV absorption arises from nonemitting, photoionized gas, then the inferred density and pressure will increase accordingly. The volume filling factor for homogeneous models ranges from 0.5% to 5%. Because of the constraints arising from filling factor and radiated power, most of the C IV must arise from gas near the peak of the cooling curve, at log t less than or equal to 5.6. We relate both emission-line and absorption-line observations to recent models in which turbulent mixing layers and isobarically cooling supernova remnants (SNRs) provide significant amounts of halo gas at approximately 10(exp 5.3) K and process 20-40 solar mass/yr with a power of approximately 10(exp 41) ergs/sec. Since the observed C IV and N V absorption scale heights have been reported to differ, at 4.9 kpc and 1.6 kpc, respectively, we examine inhomogeneous models with different exponential scale heights of T, P, and SN energy input. The ISM may change its character with distance above the Galactic plane, as superbubbles and mixing layers dominate over isolated SNRs as the source of the C IV. For appropiate scale heights, the midplane pressure is twice the homogeneous values quoted above. The O IV lambda 1034 diffuse emission line, which can be used as a temperature diagnostic of the hot gas, is predicted to be comparable in strength to that of C IV lambda 1549 (approximately 6000 photons/cu cm/s/sr. The ions C IV, N V, and O VI are predicted to show a decreasing trend in vertical extent, with the O IV scale height perhaps as low as approximately 1 kpc.

Shull, J. Michael↗

Medical Optimization Network for Space Telemedicine Resources

INTRODUCTION: Long-duration missions beyond low Earth orbit introduce new constraints to the space medical system. Beyond the traditional limitations in mass, power, and volume, consideration must be given to other factors such as the inability to evacuate to Earth, communication delays, and limitations in clinical skillsets. As NASA develops the medical system for an exploration mission, it must have an ability to evaluate the trade space of what resources will be most important. The Medical Optimization Network for Space Telemedicine Resources (MONSTR) was developed over the past year for this reason, and is now a system for managing data pertaining to medical resources and their relative importance when addressing medical conditions. METHODS: The MONSTR web application with a Microsoft SQL database backend was developed and made accessible to Tableau v9.3 for analysis and visualization. The database was initially populated with a list of medical conditions of concern for an exploration mission taken from the Integrated Medical Model (IMM), a probabilistic model designed to quantify in-flight medical risk. A team of physicians working within the Exploration Medical Capability Element of NASA's Human Research Program compiled a list diagnostic and treatment medical resources required to address best- and worst-case scenarios of each medical condition using a terrestrial standard of care and entered this data into the system. This list included both tangible resources (e.g. medical equipment, medications) and intangible resources (e.g. clinical skills required to perform a procedure). The physician team then assigned criticality values to each instance of a resource, representing the importance of that resource to diagnosing or treating its associated condition(s). Medical condition probabilities of occurrence during a Mars mission were pulled from the IMM and imported into the MONSTR database for use within a resource criticality-weighting algorithm. DISCUSSION: The MONSTR tool is a novel approach to assess the relative value of individual resources needed for the diagnosis and treatment of medical conditions. Future work will add resources for prevention and long term care of these conditions. Once data collection is complete, MONSTR will provide the operational and research communities at NASA with information to support informed decisions regarding areas of research investment, future crew training, and medical supplies manifested as part of any exploration medical system.

Rubin, D.↗

NASA's Contributions to Controlled Environment Agriculture

It may come as a surprise, but NASA has been a long-standing sponsor of controlled environment agriculture (CEA) research. This is based on the potential for using plants (crops) for life support systems in space. Through photosynthesis, crops could produce food and oxygen for humans, while removing CO2. In addition, plant transpiration could help purify waste water. NASAs interest in bioregenerative life support dates back to the late 1950s. At that time, much of the testing focused on algae, but over the years moved toward higher plants as CEA techniques improved. Throughout the 1980s and 90s, extensive testing was carried out at different universities to gather horticultural data for a range of crops, including wheat, soybean, lettuce, potato, sweet potato, cowpea, rice and more. These studies examined different electric light sources, mineral nutrition, recirculating hydroponics, effects of CO2, temperature, photosynthetic photon flux (PPF), and photoperiod on the crops, and identified cultivars that would be useful for space. Findings from these studies were then used to conduct large scale (20 sq m), closed atmosphere tests at Kennedy Space Center, and later at NASA Johnson Space Center, where plant growth chambers were linked to human habitats. Results showed that with high light input and careful horticultural management, about 20-25 sq m of crops under continuous cultivation could produce the O2 for one person, and about 40-50 sq m could produce enough dietary calories. The ability to sustain these production levels and accurately assess system costs and failures needs further study. In all likelihood, the use of plants for life support will evolve, where for early missions like the International Space Station, crops will be grown in small chambers to provide supplemental fresh foods. As mission durations and distances increase, the systems could expand to assume more of the life support burden. But the constraints of space travel require that these approaches be efficient in terms of mass, volume, and energy, which are similar to challenges facing terrestrial CEA, such as vertical agriculture systems.

Bioregenerative↗

Object-constrained meshless deformable algorithm for high speed 3D nonrigid registration between CT and CBCT

Purpose: High-speed nonrigid registration between the planning CT and the treatment CBCT data is critical for real time image guided radiotherapy (IGRT) to improve the dose distribution and to reduce the toxicity to adjacent organs. The authors propose a new fully automatic 3D registration framework that integrates object-based global and seed constraints with the grayscale-based ''demons'' algorithm. Methods: Clinical objects were segmented on the planning CT images and were utilized as meshless deformable models during the nonrigid registration process. The meshless models reinforced a global constraint in addition to the grayscale difference between CT and CBCT in order to maintain the shape and the volume of geometrically complex 3D objects during the registration. To expedite the registration process, the framework was stratified into hierarchies, and the authors used a frequency domain formulation to diffuse the displacement between the reference and the target in each hierarchy. Also during the registration of pelvis images, they replaced the air region inside the rectum with estimated pixel values from the surrounding rectal wall and introduced an additional seed constraint to robustly track and match the seeds implanted into the prostate. The proposed registration framework and algorithm were evaluated on 15 real prostate cancer patients. For each patient, prostate gland, seminal vesicle, bladder, and rectum were first segmented by a radiation oncologist on planning CT images for radiotherapy planning purpose. The same radiation oncologist also manually delineated the tumor volumes and critical anatomical structures in the corresponding CBCT images acquired at treatment. These delineated structures on the CBCT were only used as the ground truth for the quantitative validation, while structures on the planning CT were used both as the input to the registration method and the ground truth in validation. By registering the planning CT to the CBCT, a displacement map was generated. Segmented volumes in the CT images deformed using the displacement field were compared against the manual segmentations in the CBCT images to quantitatively measure the convergence of the shape and the volume. Other image features were also used to evaluate the overall performance of the registration. Results: The algorithm was able to complete the segmentation and registration process within 1 min, and the superimposed clinical objects achieved a volumetric similarity measure of over 90% between the reference and the registered data. Validation results also showed that the proposed registration could accurately trace the deformation inside the target volume with average errors of less than 1 mm. The method had a solid performance in registering the simulated images with up to 20 Hounsfield unit white noise added. Also, the side by side comparison with the original demons algorithm demonstrated its improved registration performance over the local pixel-based registration approaches. Conclusions: Given the strength and efficiency of the algorithm, the proposed method has significant clinical potential to accelerate and to improve the CBCT delineation and targets tracking in online IGRT applications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-G-JeP3-04: Estimating 4D CBCT from Prior Information and Extremely Limited Angle Projections Using Structural PCA and Weighted Free-Form Deformation

Purpose: To investigate the feasibility of using structure-based principal component analysis (PCA) motion-modeling and weighted free-form deformation to estimate on-board 4D-CBCT using prior information and extremely limited angle projections for potential 4D target verification of lung radiotherapy. Methods: A technique for lung 4D-CBCT reconstruction has been previously developed using a deformation field map (DFM)-based strategy. In the previous method, each phase of the 4D-CBCT was generated by deforming a prior CT volume. The DFM was solved by a motion-model extracted by global PCA and a free-form deformation (GMM-FD) technique, using data fidelity constraint and the deformation energy minimization. In this study, a new structural-PCA method was developed to build a structural motion-model (SMM) by accounting for potential relative motion pattern changes between different anatomical structures from simulation to treatment. The motion model extracted from planning 4DCT was divided into two structures: tumor and body excluding tumor, and the parameters of both structures were optimized together. Weighted free-form deformation (WFD) was employed afterwards to introduce flexibility in adjusting the weightings of different structures in the data fidelity constraint based on clinical interests. XCAT (computerized patient model) simulation with a 30 mm diameter lesion was simulated with various anatomical and respirational changes from planning 4D-CT to onboard volume. The estimation accuracy was evaluated by the Volume-Percent-Difference (VPD)/Center-of-Mass-Shift (COMS) between lesions in the estimated and “ground-truth” on board 4D-CBCT. Results: Among 6 different XCAT scenarios corresponding to respirational and anatomical changes from planning CT to on-board using single 30° on-board projections, the VPD/COMS for SMM-WFD was reduced to 10.64±3.04%/1.20±0.45mm from 21.72±9.24%/1.80±0.53mm for GMM-FD. Using 15° orthogonal projections, the VPD/COMS was further reduced to 1.91±0.86%/0.31±0.42mm based on SMM-WFD. Conclusion: Compared to GMM-FD technique, the SMM-WFD technique can substantially improve the 4D-CBCT estimation accuracy using extremely small scan angles to provide ultra-fast 4D verification. This work was supported by the National Institutes of Health under Grant No. R01-CA184173 and a research grant from Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

Informed total-error-minimizing priors: Interpretable cosmological parameter constraints despite complex nuisance effects

While Bayesian inference techniques are standard in cosmological analyses, it is common to interpret resulting parameter constraints with a frequentist intuition. This intuition can fail, for example, when marginalizing high-dimensional parameter spaces onto subsets of parameters, because of what has come to be known as projection effects or prior volume effects. We present the method of informed total-error-minimizing (ITEM) priors to address this problem. An ITEM prior is a prior distribution on a set of nuisance parameters, such as those describing astrophysical or calibration systematics, intended to enforce the validity of a frequentist interpretation of the posterior constraints derived for a set of target parameters (e.g., cosmological parameters). Our method works as follows. For a set of plausible nuisance realizations, we generate target parameter posteriors using several different candidate priors for the nuisance parameters. We reject candidate priors that do not accomplish the minimum requirements of bias (of point estimates) and coverage (of confidence regions among a set of noisy realizations of the data) for the target parameters on one or more of the plausible nuisance realizations. Of the priors that survive this cut, we select the ITEM prior as the one that minimizes the total error of the marginalized posteriors of the target parameters. As a proof of concept, we applied our method to the density split statistics measured in Dark Energy Survey Year 1 data. We demonstrate that the ITEM priors substantially reduce prior volume effects that otherwise arise and that they allow for sharpened yet robust constraints on the parameters of interest.

79 ASTRONOMY AND ASTROPHYSICS↗

Single-Volume Neutron Scatter Camera for High-Efficiency Neutron Imaging and Spectroscopy

Neutron detection provides an effective method to detect, locate, and characterize sources of interest to nuclear security applications. Current neutron imaging systems based on double-scatter kinematic reconstruction provide good signal vs. background discrimination and spectral capability, but suffer from poor sensitivity due to geometrical constraints. This weakness can be overcome if both neutron-proton scattering interactions are detected and resolved within one large contiguous active detector volume. We describe here a maximum likelihood approach to event reconstruction in a single-volume system with no optical segmentation and sensitivity to individual optical photons on the surfaces of the scintillator. We present results from a Geant4-based simulation establishing the feasibility of this single-volume neutron scatter camera concept given notional performance of existing photodetector and readout technologies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dynamic trajectory-based couch motion for improvement of radiation therapy trajectories in cranial SRT

Purpose: To investigate potential improvement in external beam stereotactic radiation therapy plan quality for cranial cases using an optimized dynamic gantry and patient support couch motion trajectory, which could minimize exposure to sensitive healthy tissue. Methods: Anonymized patient anatomy and treatment plans of cranial cancer patients were used to quantify the geometric overlap between planning target volumes and organs-at-risk (OARs) based on their two-dimensional projection from source to a plane at isocenter as a function of gantry and couch angle. Published dose constraints were then used as weighting factors for the OARs to generate a map of couch-gantry coordinate space, indicating degree of overlap at each point in space. A couch-gantry collision space was generated by direct measurement on a linear accelerator and couch using an anthropomorphic solid-water phantom. A dynamic, fully customizable algorithm was written to generate a navigable ideal trajectory for the patient specific couch-gantry space. The advanced algorithm can be used to balance the implementation of absolute minimum values of overlap with the clinical practicality of large-scale couch motion and delivery time. Optimized cranial cancer treatment trajectories were compared to conventional treatment trajectories. Results: Comparison of optimized treatment trajectories with conventional treatment trajectories indicated an average decrease in mean dose to the OARs of 19% and an average decrease in maximum dose to the OARs of 12%. Degradation was seen for homogeneity index (6.14% ± 0.67%–5.48% ± 0.76%) and conformation number (0.82 ± 0.02–0.79 ± 0.02), but neither was statistically significant. Removal of OAR constraints from volumetric modulated arc therapy optimization reveals that reduction in dose to OARs is almost exclusively due to the optimized trajectory and not the OAR constraints. Conclusions: The authors’ study indicated that simultaneous couch and gantry motion during radiation therapy to minimize the geometrical overlap in the beams-eye-view of target volumes and the organs-at-risk can have an appreciable dose reduction to organs-at-risk.

60 APPLIED LIFE SCIENCES↗

A search for minimum volume of Breed and Burn cores

The objective of the present study is to quantify the minimum volume a Breed and Burn (B and B) core can be designed to have and the corresponding burnup required for sustaining the breed-and-burn mode of operation based on neutronics; radiation damage constraints are ignored. The minimum radius for an idealized spherical B and B reactor is 136 cm or 110 cm for, respectively, 40% or 28% coolant volume fraction. The peak required burnup is about 25%. The minimum volume of a more realistic cylindrical B and B core is estimated to be only {approx}15% larger than that of the idealized spherical core but is only 43% of the volume of the medium-size B and B core previously designed to fit within the S-Prism reactor vessel. Thus it appears that SMR s can, in principle, be designed to have a B and B core. It was also found that the minimum volume B and B core does not necessarily coincide with the maximum permissible leakage from a core that can sustain the B and B mode of operation. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Paddle-based rotating-shield brachytherapy

Purpose: The authors present a novel paddle-based rotating-shield brachytherapy (P-RSBT) method, whose radiation-attenuating shields are formed with a multileaf collimator (MLC), consisting of retractable paddles, to achieve intensity modulation in high-dose-rate brachytherapy. Methods: Five cervical cancer patients using an intrauterine tandem applicator were considered to assess the potential benefit of the P-RSBT method. The P-RSBT source used was a 50 kV electronic brachytherapy source (Xoft Axxent™). The paddles can be retracted independently to form multiple emission windows around the source for radiation delivery. The MLC was assumed to be rotatable. P-RSBT treatment plans were generated using the asymmetric dose–volume optimization with smoothness control method [Liu et al., Med. Phys. 41(11), 111709 (11pp.) (2014)] with a delivery time constraint, different paddle sizes, and different rotation strides. The number of treatment fractions (fx) was assumed to be five. As brachytherapy is delivered as a boost for cervical cancer, the dose distribution for each case includes the dose from external beam radiotherapy as well, which is 45 Gy in 25 fx. The high-risk clinical target volume (HR-CTV) doses were escalated until the minimum dose to the hottest 2 cm{sup 3} (D{sub 2cm{sup 3}}) of either the rectum, sigmoid colon, or bladder reached their tolerance doses of 75, 75, and 90 Gy{sub 3}, respectively, expressed as equivalent doses in 2 Gy fractions (EQD2 with α/β = 3 Gy). Results: P-RSBT outperformed the two other RSBT delivery techniques, single-shield RSBT (S-RSBT) and dynamic-shield RSBT (D-RSBT), with a properly selected paddle size. If the paddle size was angled at 60°, the average D{sub 90} increases for the delivery plans by P-RSBT on the five cases, compared to S-RSBT, were 2.2, 8.3, 12.6, 11.9, and 9.1 Gy{sub 10}, respectively, with delivery times of 10, 15, 20, 25, and 30 min/fx. The increases in HR-CTV D{sub 90}, compared to D-RSBT, were 16.6, 12.9, 7.2, 3.7, and 1.7 Gy{sub 10}, respectively. P-RSBT HR-CTV D{sub 90}-values were insensitive to the paddle size for paddles angled at less than 60°. Increasing the paddle angle from 5° to 60° resulted in only a 0.6 Gy{sub 10} decrease in HR-CTV D{sub 90} on average for five cases when the delivery times were set to 15 min/fx. The HR-CTV D{sub 90} decreased to 2.5 and 11.9 Gy{sub 10} with paddle angles of 90° and 120°, respectively. Conclusions: P-RSBT produces treatment plans that are dosimetrically and temporally superior to those of S-RSBT and D-RSBT, although P-RSBT systems may be more mechanically challenging to develop than S-RSBT or D-RSBT. A P-RSBT implementation with 4–6 shield paddles would be sufficient to outperform S-RSBT and D-RSBT if delivery times are constrained to less than 15 min/fx.

60 APPLIED LIFE SCIENCES↗