Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Ultraviolet light”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Theoretical and experimental study on the O( 3 P) + 2,5-dimethylfuran reaction in the gas phase

In this work we report a joint experimental and computational study on the 2,5-dimethylfuran oxidation reaction in the gas phase initiated by atomic oxygen O( 3 P). The experiments have been performed by using vacuum-ultraviolet synchrotron radiation at the Advanced Light Source (ALS) of the Lawrence Berkeley National Laboratory (LBNL), at a temperature of 550 K and a pressure of 8 Torr. The experimental data were supported by quantum-chemical calculations along with a kinetic model, also taking into account the possible involvement of different magnetic states, performed in the framework of the RRKM theory. Propyne, acetaldehyde, methylglyoxal, dimethylglyoxal, 3-penten-2-one, 2,5-dimethylfuran-3(2 H )-one, and 1,2-diacetyl ethylene have been identified as the main primary products arising under the conditions of the experiment. Our computational model suggests that these species can be formed at the concentration and branching ratio experimentally observed only in the presence of a non-negligible fraction of non-thermalized intermediates.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Neural Density Estimation and Uncertainty Quantification for ChemCam Spectra [Slides]

The ChemCam instrument of Curiosity uses laser-induced breakdown spectroscopy (LIBS). It fires a laser at target and vaporizes rock surfaces, creating a plasma. Three spectrographs divide the plasma light into wavelengths for chemical analysis: ultraviolet, violet, and visible near-infrared. Regression methods (SVR, PCR, CNN) have been employed for calibration (prediction of the elemental composition of samples); however, labeled ChemCam samples are limited. Here, we focus on unsupervised learning and employ generative models from ChemCam analysis. Further, we use labels (supervised) in combination to the generative model to compute uncertainties related to predictions. We report generative modeling can be successfully applied to model real-world data. Normalizing flow models can be efficiently constructed on latent spaces for fast downstream inference. Unsupervised and supervised learning can be combined to form an uncertainty quantification framework.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Initial Benchmarks of UV LEDs and Comparisons with White LEDs

The primary goal of this report is to benchmark the initial level of performance of a selection of commercial UV LEDs across all three bands (i.e., UV-A, UV-B, UV-C). To provide the initial performance benchmarks, a test matrix containing 13 different UV LED products was created in association with the LED Systems Reliability Consortium (LSRC). The products in this test matrix were all commercially available as of June 2021, and at least 22 samples of each product were tested. In addition, two common, commercial white LEDs were tested to provide a benchmark against blue-pumped white LEDs. Testing of the samples included electrical performance testing (e.g., current-voltage measurements) and photometric testing in a calibrated integrating sphere capable of measuring devices in the UV-A, UV-B, and UV-C bands. The electrical testing provided insights into the performance of the semiconductor layers in the LEDs, allowing parameters such as the threshold voltage (V th ) and serial resistance (R serial ) of each sample to be determined. The photometric testing provided insights into emission wavelengths, peak shapes, and radiant efficiencies for each sample. Combined, the information from these tests permits the overall device efficiencies to be compared and provides insights into the electrical and optical performance of the technology.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Silver Nanoparticles Functionalized Nanosilica Grown over Graphene Oxide for Enhancing Antibacterial Effect

The continuous growth of multidrug-resistant bacteria due to the overuse of antibiotics and antibacterial agents poses a threat to human health. Silver nanoparticles, silica-based materials, and graphene-based materials have become potential antibacterial candidates. In this study, we developed an effective method of enhancing the antibacterial property of graphene oxide (GO) by growing nanosilica (NS) of approximately 50 nm on the graphene oxide (GO) surface. The structures and compositions of the materials were characterized through powdered X-ray diffraction (P-XRD), transmission electron microscopy (TEM), scanning electron microscopy coupled with energy dispersive X-ray spectroscopy (SEM-EDS), ultraviolet–visible spectroscopy (UV–VIS), dynamic light scattering (DLS), Raman spectroscopy (RM), Fourier-transform infrared spectroscopy (FTIR), Brunauer–Emmet–Teller (BET) surface area, and pore size determination. The silver nanoparticles (AgNPs) with an average diameter of 26 nm were functionalized on the nanosilica (NS) surface. The composite contained approximately 3% of silver nanoparticles. The silver nanoparticles on nanosilica supported over graphene oxide (GO/NS/AgNPs) exhibited a 7-log reduction of Escherichia coli and a 5.2-log reduction of Bacillus subtilis within one hour of exposure. Both GO/NS and GO/NS/AgNPs exhibited substantial antimicrobial effects against E. coli and B. subtilis.

36 MATERIALS SCIENCE↗

Thin carbon film serves as UV bandpass filter

Thin carbon film deposited on a 70 percent transparent screen provides a filter for narrow-band detectors in the extreme ultraviolet. The filter also suppresses scattered light and light of unwanted orders in vacuum spectrographs.

Source record↗

In-flight analysis of IUE cross-disperser scattered light

The scattered light properties of the IUE (International Ultraviolet Explorer) cross-disperser gratings are investigated using in-flight data of the emission spectrum of Comet Bradfield (1979X). The scattering function in the vicinity of H I Lyman alpha at 1216 angstroms is found to be significantly lower than that derived from either the laboratory measurements of Mount and Fastie (1978) or the analysis by Basri et al. (1985) of cool star observations.

Feldman, P. D.↗

Carbon stars with alpha-C:H emission

Many carbon stars in the IRS low resolution spectra (LRS) catalog were found which display emission spectra that compare favorable with the absorption spectrum of alpha-C:H. These stars have largely been classified as 4X in the LRS which has led to their interpretation by others in terms of displaying a mixture of the UIRF's 8.6 micron band and SiC at 11.5 microns. It was also found that many of these stars have a spectral upturn at 20+ microns which resembles the MgS band seen in carbon stars and planetary nebulae. It was concluded that this group of carbon stars will evolve into planetary nebulae like NGC 7027 and IC 418. In the presence of hard ultraviolet radiation the UIRF's will light up and be displayed as narrow emission bands on top of the broad alpha-C:H emission bands.

Gerbault, Florence↗

Testing for X-ray Periodicities in Seyfert Galaxies

The Deep Survey instrument on the Extreme Ultraviolet Explorer obtained long, continuous light-curves of 10 Seyfert galaxies with durations of 5-33 days each. We present a uniform reduction of these data, which account for a total of 209 days of observation. Several of the light curves are uniquely suited to a search for periodicity or QPOs in the range of hours to days that might be expected from dynamical effects in the inner accretion disks around approximately 10(exp 8) solar mass black holes. Power spectra show features in three of the longest observations that could be transient periods: 0.9 days in RX J0437.4-4711, 2.1 days in Ton S180, and 5.8 days in 1H 0419-577. These period values seem to be unrelated to the length of the observations, which are similar in the three cases, but they do roughly scale as the luminosity of the objects, which would be expected in a dynamical scenario if the black hole masses also scale with luminosity. The significance of these periods will be evaluated in a future publication by using the method of Timmer & Konig (1995), which properly takes into account the red-noise properties of AGN light curves.

Halpern, Jules P.↗

An LED Approach for Measuring the Photocatalytic Breakdown of Crystal Violet Dye

A simple technique to assess the reactivity of photocatalytic coatings sprayed onto transmissive glass surfaces was developed. This new method uses ultraviolet (UV) gallium nitride (GaN) light-emitting diodes (LEDs) to drive a photocatalytic reaction (the photocatalytic breakdown of a UV-resistant dye applied to a surface coated with the semiconductor titanium dioxide); and then a combination of a stabilized white light LED and a spectrometer to track the dye degradation as a function of time. Simple, standardized evaluation techniques that assess photocatalytic materials over a variety of environmental conditions, including illumination level, are not generally available and are greatly needed prior to in situ application of photocatalytic technologies. To date, much research pertaining to this aspect of photocatalysis has been limited and has focused primarily on laboratory experiments using mercury lamps. Mercury lamp illumination levels are difficult to control over large ranges and are temporally modulated by line power, limiting their use in helping to understand and predict how photocatalytic materials will behave in natural environmental settings and conditions. The methodology described here, using steady-state LEDs and time series spectroradiometric techniques, is a novel approach to explore the effect of UV light on the photocatalytic degradation of a UV resistant dye (crystal violet). GaN UV LED arrays, centered around 365 nm with an adjustable DC power supply, are used to create a small, spatially uniform light field where the steady state light level can be varied over three to four orders of magnitude. For this study, a set of glass microscope slides was custom coated with a thinly sprayed layer of photocatalytic titanium dioxide. Crystal violet was then applied to these titanium-dioxide coated slides and to uncoated control slides. The slides were then illuminated at various light levels from the dye side of the slide by the UV LED array. To monitor dye degradation on the slides over time, a temperature-stabilized white light LED was used to illuminate the opposite side of the slides. As the dye degraded, the amount of light from the white light LED transmitted through the slide was monitored with a spectrometer and subsequently analyzed to determine and compare the rate of dye degradation for photocatalytically coated versus uncoated slide surfaces. The long-term stability of the spectrometer/white light LED combination, which required only a single reference spectra to be taken for a time series sequence of several hours, enabled accurate measurements of transmitted light over time. Time series transmission curves were generated and results demonstrated that over time the transmission increased much more rapidly on the coated slides than on the control slides. This experimental configuration and methodology for photocatalytic activity measurement minimizes many external variable effects and allows low light level studies to be performed. This study also compares the advantages of this novel LED light source design to traditional mercury lamp systems and non-LED lamp approaches that have conventionally been used. The methodology and experimental design research summarized in this abstract is partly funded by the Department of Homeland Security, Science and Technology Directorate, and by the NASA Stennis Space Center Innovative Partnerships Program.

Ryan, Robert E.↗

Fast Imaging Detector Readout Circuits with In-Pixel ADCs for Fourier Transform Imaging Spectrometers

Focal plane arrays (FPAs) with high frame rates and many pixels benefit several upcoming Earth science missions including GEO-CAPE, GACM, and ACE by enabling broader spatial coverage and higher spectral resolution. FPAs for the PanFTS, a high spatial resolution Fourier transform spectrometer and a candidate instrument for the GEO-CAPE mission are the focus of the developments reported here, but this FPA technology has the potential to enable a variety of future measurements and instruments. The ESTO ACT Program funded the developed of a fast readout integrated circuit (ROIC) based on an innovative in-pixel analog-to-digital converter (ADC). The 128 X 128 pixel ROIC features 60 ?m pixels, a 14-bit ADC in each pixel and operates at a continuous frame rate of 14 kHz consuming only 1.1 W of power. The ROIC outputs digitized data completely eliminating the bulky, power consuming signal chains needed by conventional FPAs. The 128 X 128 pixel ROIC has been fabricated in CMOS and tested at the Jet Propulsion Laboratory. The current version is designed to be hybridized with PIN photodiode arrays via indium bump bonding for light detection in the visible and ultraviolet spectral regions. However, the ROIC design incorporates a small photodiode in each cell to permit detailed characterization of the ROICperformance without the need for hybridization. We will describe the essential features of the ROIC design and present results of ROIC performance measurements.

focal plane arrays (FPAs)↗

Nitrogen Dioxide Observations from the Geostationary Trace Gas and Aerosol Sensor Optimization (GeoTaso) Airborne Instrument: Retrieval Algorithm and Measurements During DISCOVER-AQ Texas 2013

The Geostationary Trace gas and Aerosol Sensor Optimization (GeoTASO) airborne instrument is a test bed for upcoming air quality satellite instruments that will measure backscattered ultraviolet, visible and near-infrared light from geostationary orbit. GeoTASO flew on the NASA Falcon aircraft in its first intensive field measurement campaign during the Deriving Information on Surface Conditions from Column and Vertically Resolved Observations Relevant to Air Quality (DISCOVER-AQ) Earth Venture Mission over Houston, Texas, in September 2013. Measurements of backscattered solar radiation between 420 and 465 nm collected on 4 days during the campaign are used to determine slant column amounts of NO2 at 250 m x 250 m spatial resolution with a fitting precision of 2.2 x 10(exp 15) molecules/sq cm. These slant columns are converted to tropospheric NO2 vertical columns using a radiative transfer model and trace gas profiles from the Community Multiscale Air Quality (CMAQ) model. Total column NO2 from GeoTASO is well correlated with ground-based Pandora observations (r = 0.90 on the most polluted and cloud-free day of measurements and r = 0.74 overall), with GeoTASO NO2 slightly higher for the most polluted observations. Surface NO2 mixing ratios inferred from GeoTASO using the CMAQ model show good correlation with NO2 measured in situ at the surface during the campaign (r = 0.85). NO2 slant columns from GeoTASO also agree well with preliminary retrievals from the GEO-CAPE Airborne Simulator (GCAS) which flew on the NASA King Air B200 (r = 0.81, slope = 0.91). Enhanced NO2 is resolvable over areas of traffic NOx emissions and near individual petrochemical facilities.

Aerosol Sensor Optimization↗

Alternating Twist Along an Erupting Prominence

Triangulation measurements using observations from the two Solar Terrestrial Relations Observatory (STEREO) spacecraft, combined with observations from the Solar Dynamics Observatory (SDO), are used to characterize the behavior of a prominence involved in two successive coronal mass ejections 6-7 December 2010. The STEREO separation at the time was 171.6 degrees, which was functionally equivalent to a separation of 8.4 degrees, and thus very favorable for feature co-identification above the limb. The first eruption at approximately 14:16 UT (Universal Time) on 6 December of the middle branch of the prominence starts off a series of magnetic reconfigurations in the right branch, which itself erupts at approximately 2:06 UT the next day, about 12 hours after the first eruption. The cool prominence material seen at 304 angstroms drains back down to the surface, but a flux-rope-like magnetic structure is seen to erupt in both 195 angstroms by the STEREO/Extreme Ultraviolet Imager (EUVI), and in white light by the STEREO/COR1 (Coronagraph 1) inner coronagraph. In between the two eruptions, two different signs of helicity are seen in the measured twist of the right branch. This is interpreted to be caused by the overall prominence channel being composed of different segments with alternating helicity signs. The erupting parts on 6 and 7 December both show positive twist, but negative twist is seen in between these positive sections. Negative twist is consistent with the dextral chirality signs seen in the He II line at 304 angstroms prior to both eruptions. However, during the period between the eruptions, a region of positive twist grows and replaces the region of negative twist, and finally erupts. We interpret these observations in the light of models that predict that helicity cancellation can be an important factor in the triggering of flares and coronal mass ejections.

Prominences↗

Heat-Exchange Driven Aircraft for Low Altitude and Surface Exploration of Venus: Phase 1 Study Final Report

Exploration of Venus below its clouds has long been impaired by the planet’s massive CO2 atmosphere, corrosive trace gases, and high opacity. Except for a few narrow spectral windows, the 20 km thick global cloud cover blocks light over the entirety of the ultraviolet through thermal infrared spectrum, impeding orbital studies of the surface and lower portion of the atmosphere. In addition to the cloud opacity, Rayleigh scattering through 80 bars of CO 2 in the lower 40 km of the atmosphere results in a Rayleigh scattering depth between 25 and1 in the visible through near infrared portion of the spectrum. That optically thick scattering, combined with the uniform angular distribution of the illumination provided by the highly diffusing clouds overhead greatly reduces even very large surface albedo contrasts (Crisp, pers. Comm.). To date, the surface has only been mapped via synthetic aperture radar by the Magellan mission at scales of 120 to 300 m/pixel. In addition to contributing to the difficulty of performing studies of the surface from orbit, the extreme temperatures and pressures at the surface also create a challenging environment to utilize a lander for exploration. The longest-lived lander on Venus’ surface survived for 2 hours. Hence, limited access to observe the surface and lower atmosphere of Venus arguably puts the surface and lower atmosphere of Venus as one of the least explored regions of the inner Solar System.

NIAC Phase I↗

Tantalum pentoxide: a new material platform for high-performance dielectric metasurface optics in the ultraviolet and visible region

Dielectric metasurfaces, composed of planar arrays of subwavelength dielectric structures that collectively mimic the operation of conventional bulk optical elements, have revolutionized the field of optics by their potential in constructing high-efficiency and multi-functional optoelectronic systems on chip. The performance of a dielectric metasurface is largely determined by its constituent material, which is highly desired to have a high refractive index, low optical loss and wide bandgap, and at the same time, be fabrication friendly. Here, we present a new material platform based on tantalum pentoxide (Ta 2 O 5 ) for implementing high-performance dielectric metasurface optics over the ultraviolet and visible spectral region. This wide-bandgap dielectric, exhibiting a high refractive index exceeding 2.1 and negligible extinction coefficient across a broad spectrum, can be easily deposited over large areas with good quality using straightforward physical vapor deposition, and patterned into high-aspect-ratio subwavelength nanostructures through commonly-available fluorine-gas-based reactive ion etching. We implement a series of high-efficiency ultraviolet and visible metasurfaces with representative light-field modulation functionalities including polarization-independent high-numerical-aperture lensing, spin-selective hologram projection, and vivid structural color generation, and the devices exhibit operational efficiencies up to 80%. Our work overcomes limitations faced by scalability of commonly-employed metasurface dielectrics and their operation into the visible and ultraviolet spectral range, and provides a novel route towards realization of high-performance, robust and foundry-manufacturable metasurface optics.

36 MATERIALS SCIENCE↗

Miniature personal UV solar dosimeter

Small light-powered meter measures accumulated radiation in ultraviolet or other selected regions. Practical advantages are device's low cost, small size, accuracy, and adaptability to specific wave-band measurements. Medical applications include detection of skin cancer, vitamin D production, and jaundice. Dosimeter also measures sunlight for solar energy designs, agriculture and meteorology, and monitors stability of materials and environmental and occupational lighting.

Adams, R. R.↗

Space Telescope and Optical Reverberation Mapping Project. VI. Reverberating Disk Models for NGS 5548

We conduct a multi-wavelength continuum variability study of the Seyfert 1 galaxy NGC 5548 to investigate the temperature structure of its accretion disk. The 19 overlapping continuum light curves (1158 Angstrom to 9157 Angstrom) combine simultaneous Hubble Space Telescope, Swift, and ground-based observations over a 180 day period from 2014 January to July. Light-curve variability is interpreted as the reverberation response of the accretion disk to irradiation by a central time-varying point source. Our model yields the disk inclination i = 36deg +/- 10deg, temperature T(sub 1) = (44+/-6) times 10 (exp 3)K at 1 light day from the black hole, and a temperature radius slope (T proportional to r (exp -alpha)) of alpha = 0.99 +/- 0.03. We also infer the driving light curve and find that it correlates poorly with both the hard and soft X-ray light curves, suggesting that the X-rays alone may not drive the ultraviolet and optical variability over the observing period. We also decompose the light curves into bright, faint, and mean accretion-disk spectra. These spectra lie below that expected for a standard blackbody accretion disk accreting at L/L(sub Edd) = 0.1.

accretion↗

Multiple wavelength light collimator and monitor

An optical system for receiving and collimating light and for transporting and processing light received in each of N wavelength ranges, including near-ultraviolet, visible, near-infrared and mid-infrared wavelengths, to determine a fraction of light received, and associated dark current, in each wavelength range in each of a sequence of time intervals.

Gore, Warren J.↗

Six-color photometry of Iapetus, Titan, Rhea, Dione and Tethys

Six-color photometric observations made during Saturn's 1972/73 opposition enable us to separate the solar phase and orbital phase contributions to the observed light variations of Iapetus, Titan, Rhea, Dione and Tethys. Titan shows no orbital variations, but has phase coefficients which range from negligible values in the infrared to 0.014 mag/deg in the ultraviolet. Rhea has a bright leading side, a light curve amplitude of about 0.2 mag, and surprisingly large phase coefficients. Combined with other available information, the observations suggest a very porous, texturally complex surface layer. Dione has a leading side which is a few tenths of a magnitude brighter than the trailing side, but the light curve amplitude has little wavelength dependence and the phase coefficients are significantly smaller than those of Rhea, suggesting a less intricate surface texture. The leading side of Tethys is probably a few tenths of a magnitude brighter than the trailing side. Our Iapetus observations generally supplement the earlier work by Millis.

Noland, M.↗