Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “UNDERGROUND”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Design and implementation of the AMIGA embedded system for data acquisition

The Auger Muon Infill Ground Array (AMIGA) is part of the AugerPrime upgrade of the Pierre Auger Observatory. It consists of particle counters buried 2.3 m underground next to the water-Cherenkov stations that form the 23.5 km 2 large infilled array. The reduced distance between detectors in this denser area allows the lowering of the energy threshold for primary cosmic ray reconstruction down to about 1017 eV. At the depth of 2.3 m the electromagnetic component of cosmic ray showers is almost entirely absorbed so that the buried scintillators provide an independent and direct measurement of the air showers muon content. This work describes the design and implementation of the AMIGA embedded system, which provides centralized control, data acquisition and environment monitoring to its detectors. The presented system was firstly tested in the engineering array phase ended in 2017, and lately selected as the final design to be installed in all new detectors of the production phase. The system was proven to be robust and reliable and has worked in a stable manner since its first deployment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and optimization of the RF input-coupler for a low-frequency, split-coaxial RFQ

The Isotope Decay-At-Rest experiment (IsoDAR) is a proposed underground experiment which is expected to be a definitive search for sterile neutrinos. In order to be decisive within 5 years, high rates of neutrinos must be produced, by impinging a 10 mA continuous wave proton beam at 60 MeV on a high power target. Due to space restrictions, a compact cyclotron was chosen as an accelerator to produce this driver beam. To overcome space charge limitations during injection, H 2 + ions are accelerated and later stripped into protons by means of a carbon foil. IsoDAR uses an especially designed low-frequency (32.8 MHz) split-coaxial Radio-Frequency Quadrupole (RFQ) to effectively bunch H 2 + ions before injecting them into this cyclotron. The RFQ will be embedded vertically in the cyclotron yoke, facilitating a very compact design. This puts stringent limits on RFQ size, type, and accessibility. Here, we present the design and optimization of the low-frequency (32.8 MHz) RF input-coupler for the IsoDAR RFQ. The design is challenging due to the necessarily small diameter of the RFQ (28 cm) and the split-coaxial type, as well as limited access to the RFQ. We have determined the optimal position and shape for the coupler, leading to a low power consumption of < 6 kW for an inter-vane voltage of 22 kV. Finally, the highest calculated fields are safely below the Kilpatrick limit for this structure.

43 PARTICLE ACCELERATORS↗

Optical calibration of the SNO+ detector in the water phase with deployed sources

SNO+ is a large-scale liquid scintillator experiment with the primary goal of searching for neutrinoless double beta decay, and is located approximately 2 km underground in SNOLAB, Sudbury, Canada. The detector acquired data for two years as a pure water Cherenkov detector, starting in May 2017. During this period, the optical properties of the detector were measured in situ using a deployed light diffusing sphere, with the goal of improving the detector model and the energy response systematic uncertainties. The measured parameters included the water attenuation coefficients, effective attenuation coefficients for the acrylic vessel, and the angular response of the photomultiplier tubes and their surrounding light concentrators, all across different wavelengths. Finally, the calibrated detector model was validated using a deployed tagged gamma source, which showed a 0.6% variation in energy scale across the primary target volume.

47 OTHER INSTRUMENTATION↗

Development of a High Throughput PCIe Card for DAQ System in the ATLAS and DUNE Experiments

In the Run 3 upgrade of ATLAS experiment, the FELIX (Front-End LInk eXchange) system has been prepared as the interface between front-end electronics and common Data Acquisition (DAQ) systems. Based on a PCIe card hosted in commodity server, FELIX's flexibilty makes it has also been adopted by other experiments, such as the Single-Phase ProtoDUNE (Prototype for the Deep Underground Neutrino Experiment), sPHENIX and CBM experiments. The same PCIe based architecture is proposed for use in the ATLAS HL-LHC (High Luminosity Large Hadron Collider) upgrade and the DUNE experiment. To this end, the next generation of FELIX I/O card FLX-801 has been developed. It supports 25+ Gbps high speed fiber optical links and 16-lane Gen4 PCIe interface. There is an on-card DDR4 module to buffer event data for DUNE experiment. This paper reports on the test results for the demonstrator of this next generation card, with which main functions have been successfully evaluated.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characterization of Silicon-Photomultipliers for a Cosmic Muon Veto detector

A Cosmic Muon Veto (CMV) detector using extruded scintillators is being designed around the mini-Iron Calorimeter detector at the transit campus of the India-based Neutrino Observatory, Madurai for measuring its efficiency at shallow depth underground experiments. The scintillation signal is transmitted through a Wavelength Shifting (WLS) fibre and readout by Hamamatsu Silicon-Photomultipliers (SiPMs). A Light Emitting Diode (LED) system is included on the front-end readout for in-situ calibration of the gain of each SiPM. A characterization system was developed for the measurement of gain and choice of the overvoltage (V ov ) of SiPMs using the LED as well as a cosmic muon telescope. The V ov is obtained by studying the noise rate, the gain of the SiPM, and the muon detection efficiency. In case of any malfunction of the LED system during the operation, the SiPM can also be calibrated with the noise data as well as using radioactive sources. Furthermore, this paper describes the basic characteristics of the SiPM and the comparison of the calibration results using all three methods, as well as the V ov of the SiPMs and muon selection criteria for the veto detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Scintillation light detection in the 6-m drift length ProtoDUNE Dual Phase liquid argon TPC

The Deep Underground Neutrino Experiment (DUNE) is a leading-edge experiment for long-baseline neutrino oscillation studies, neutrino astrophysics and nucleon decay searches. ProtoDUNE-Dual Phase (DP) is a 6 × 6 × 6 m$^{3}$ liquid argon time-projection-chamber (LArTPC) operated at the CERN Neutrino Platform in 2019–2020 as a prototype of the DUNE far detector. In ProtoDUNE-DP, the scintillation and electroluminescence light produced by cosmic muons in the LArTPC is collected by photomultiplier tubes placed up to 7 m away from the ionizing track. In this paper, we present the performance of the ProtoDUNE-DP photon detection system, comparing different wavelength-shifting techniques and the use of xenon-doped LAr as a promising option for future large LArTPCs. The scintillation light production and propagation processes are analyzed and compared to simulations, improving understanding of the liquid argon properties.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Xenon doping of liquid argon in ProtoDUNE single phase

The Deep Underground Neutrino Experiment (DUNE) will be the next generation long-baseline neutrino experiment. The far detector is designed as a complex of four LAr-TPC (Liquid Argon Time Projection Chamber) modules with 17 kt of liquid argon each. The development and validation of the first far detector technology is pursued through ProtoDUNE Single Phase (ProtoDUNE-SP), a 770 t LAr-TPC at CERN Neutrino Platform. Crucial in DUNE is the photon detection system that will ensure the trigger of non-beam events — proton decay, supernova neutrino burst and BSM searches — and will improve the timing and calorimetry for neutrino beam events. Doping liquid argon with xenon is a known technique to shift the light emitted by argon (128 nm) to a longer wavelength (178 nm) to ease its detection. The largest xenon doping test ever performed in a LAr-TPC was carried out in ProtoDUNE-SP. From February to May 2020, a gradually increasing amount of xenon was injected to also compensate for the light loss due to air contamination. The response of such a large TPC has been studied using the ProtoDUNE-SP Photon Detection System (PDS) and a dedicated setup installed before the run. With the first it was possible to study the light collection efficiency with respect to the track position, while with the second it was possible to distinguish the xenon light (178 nm) from the LAr light (128 nm). The light shifting mechanism proved to be highly efficient even at small xenon concentrations (<20 ppm in mass) furthermore it allowed recovering the light quenched by pollutants. The light collection improved far from the detection plane, enhancing the photon detector response uniformity along the drift direction and confirming a longer Rayleigh scattering length for 178 nm photons, with respect to 128 nm ones. The charge collection by the TPC was monitored proving that xenon up to 20 ppm does not impact its performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An energy-dependent electro-thermal response model of CUORE cryogenic calorimeter

The Cryogenic Underground Observatory for Rare Events (CUORE) is the most sensitive experiment searching for neutrinoless double-beta decay (0νββ) in 130 Te. CUORE uses a cryogenic array of 988 TeO 2 calorimeters operated at ~10 mK with a total mass of 741 kg. To further increase the sensitivity, the detector response must be well understood. Here, we present a non-linear thermal model for the CUORE experiment on a detector-by-detector basis. We have examined both equilibrium and dynamic electro-thermal models of detectors by numerically fitting non-linear differential equations to the detector data of a subset of CUORE channels which are well characterized and representative of all channels. Further, we demonstrate that the hot-electron effect and electric-field dependence of resistance in NTD-Ge thermistors alone are inadequate to describe our detectors' energy-dependent pulse shapes. We introduce an empirical second-order correction factor in the exponential temperature dependence of the thermistor, which produces excellent agreement with energy-dependent pulse shape data up to 6 MeV. We also present a noise analysis using the fitted thermal parameters and show that the intrinsic thermal noise is negligible compared to the observed noise for our detectors.

47 OTHER INSTRUMENTATION↗

Detection efficiency measurement and operational tests of the X-Arapuca for the first module of DUNE far detector

The Deep Underground Neutrino Experiment (DUNE) is a dual-site experiment for long-baseline neutrino oscillation studies, able to resolve the neutrino mass hierarchy and measure δ$_{CP}$. DUNE will also have sensitivity to supernova neutrinos and to processes beyond the Standard Model, such as nucleon decay searches. The Far Detector (FD) will consist of four liquid argon TPC (17.5 kt total mass) with systems for the detection of charge and scintillation light produced by an ionization event. The charge detection system permits both calorimetry and position determination. In addition, the photon-detection system (PDS) enhances the detector capabilities for all DUNE physics drivers. The PDS of the first FD module consists of light collector modules placed in the inactive space between the innermost wire planes of the TPC anode. The light collectors, the so-called X-ARAPUCAS, are functionally a light trap that captures wavelength-shifted photons inside boxes with highly reflective internal surfaces where they are guided to Silicon Photo-multipliers (SiPM) by wavelength-shifting (WLS) bars. Functionality and operational tests of the X-ARAPUCAS to be installed in ProtoDUNE-SP phase II (FD DUNE prototype at the scale 1:20), as well as the measurement of their absolute detection efficiency is reported in this publication.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Calibration sources for the LEGEND-200 experiment

In the search for a monochromatic peak as the signature of neutrinoless double beta decay an excellent energy resolution and an ultra-low background around the Q-value of the decay are essential. The LEGEND-200 experiment performs such a search with high-purity germanium detectors enriched in 76 Ge immersed in liquid argon. To determine and monitor the stability of the energy scale and resolution of the germanium diodes, custom-made, low-neutron emission 228 Th sources are regularly deployed in the vicinity of the crystals. Here we describe the production process of the 17 sources available for installation in the experiment, the measurements of their alpha- and gamma- activities, as well as the determination of the neutron emission rates with a low-background LiI(Eu) detector operated deep underground. With a flux of ( 4.27 ± 0.60 stat ± 0.92 syst ) × 10 -4 n / (kBq·s), approximately one order of magnitude below that of commercial sources, the neutron-induced background rate, mainly from the activation of 76 Ge, is negligible compared to other background sources in LEGEND-200.

47 OTHER INSTRUMENTATION↗

Scintillation light detection performance for the DUNE ND-LAr 2 × 2 modules

The Deep Underground Neutrino Experiment (DUNE) will be using a liquid argon time projection chamber (LAr TPC) with optically separated modules in the Near Detector (ND) complex. A prototype experiment, DUNE ND-LAr 2 × 2, is composed of four test modules. They detect ionization charge through a pixel-based readout and scintillation light through fibers in light collection modules and light traps called ArCLights. The light detection performance for two modules of DUNE ND-LAr 2 × 2 that took cosmic ray data at the University of Bern is shown. We present further the role of the 2 × 2 prototype in DUNE and how it is used to demonstrate the reconstruction capabilities of its light detectors in terms of energy thresholds and timing resolution.

47 OTHER INSTRUMENTATION↗

Energy resolution of the LZ detector for high-energy electronic recoils

The LUX-ZEPLIN (LZ) detector is a dual-phase liquid xenon time projection chamber (TPC) installed at the Sanford Underground Research Facility (Lead, South Dakota) at a depth of 1478 meters. Although the main objective of LZ is the direct detection of dark matter, its low background environment allows for the search of other rare processes, such as the neutrinoless double beta decay of xenon isotopes 134 Xe and 136 Xe with the respective Q-values of 826 keV and 2458 keV. The sensitivity of the detector to these decays is directly determined by the energy resolution, which, in turn, is degraded by non-uniformities in detector response. In this work, we present a novel method to correct, in the data, the non-uniformity of the light collected by an array of photosensors in a scintillation detector. This method is based on the knowledge of the light response functions of individual photosensors. With these techniques, we report, at a very early phase of the detector operations, a state-of-the-art energy resolution (σ/μ) of (0.67 ± 0.01)% at 2614 keV for the fiducial volume of 5.6 tonnes of liquid xenon.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Production and testing of the large-area photon detector ArCLight

Compact large-area dielectric photon detectors that ensure modular noble liquid detectors can sense scintillation light signals for triggering and reconstruction purposes with minimal impact to the overall target volume. ArCLight is a small-volume, sizeable sensitive-area detector that consists of a light trap covered in a thin layer of TPB that can be placed inside a time projection chamber's electric field. These sensors are used in the Deep Underground Neutrino Experiment Near Detector liquid argon (DUNE ND-LAr). They are constructed and tested at the University of Bern and will be deployed in the prototype experiment ProtoDUNE-ND. The talk discusses the details of assembling ArCLights, the quality control methods, and the test studies done with LEDs to assess their performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Twelve-crystal prototype of Li 2 MoO 4 scintillating bolometers for CUPID and CROSS experiments

An array of twelve 0.28 kg lithium molybdate (LMO) low-temperature bolometers equipped with 16 bolometric Ge light detectors, aiming at optimization of detector structure for CROSS and CUPID double-beta decay experiments, was constructed and tested in a low-background pulse-tube-based cryostat at the Canfranc underground laboratory in Spain. Performance of the scintillating bolometers was studied depending on the size of phonon NTD-Ge sensors glued to both LMO and Ge absorbers, shape of the Ge light detectors (circular vs. square, from two suppliers), in different light collection conditions (with and without reflector, with aluminum coated LMO crystal surface). The scintillating bolometer array was operated over 8 months in the low-background conditions that allowed to probe a very low, μBq/kg, level of the LMO crystals radioactive contamination by 228 Th and 226 Ra.

47 OTHER INSTRUMENTATION↗

Energy calibration of germanium detectors for the Majorana Demonstrator

The Majorana Demonstrator was a search for neutrinoless double-beta decay (0νββ) in the 76 Ge isotope. It was staged at the 4850-foot level of the Sanford Underground Research Facility (SURF) in Lead, SD. The experiment consisted of 58 germanium detectors housed in a low background shield and was calibrated once per week by deploying a 228 Th line source for 1 to 2 hours. The energy scale calibration determination for the detector array was automated using custom analysis tools. We describe the offline procedure for calibration of the Demonstrator germanium detectors, including the simultaneous fitting of multiple spectral peaks, estimation of energy scale uncertainties, and the automation of the calibration procedure.

47 OTHER INSTRUMENTATION↗

Ultra low background Micromegas detectors for BabyIAXO solar axion search

Abstract The International AXion Observatory (IAXO) is a large scale axion helioscope that will look for axions and axion-like particles produced in the Sun with unprecedented sensitivity. BabyIAXO is an intermediate experimental stage that will be hosted at DESY (Germany) and that will test all IAXO subsystems serving as a prototype for IAXO but at the same time as a fully-fledged helioscope with potential for discovery.One of the crucial components of the project is the ultra-low background X-ray detectors that will image the X-ray photons produced by axion conversion in the experiment. The baseline detection technology for this purpose are Micromegas (Microbulk) detectors. We will show the quest and the strategy to attain the very challenging levels of background targeted for BabyIAXO that need a multi-approach strategy coming from ground measurements, screening campaigns of components of the detector, underground measurements, background models, in-situ background measurements as well as powerful rejection algorithms. First results from the commissioning of the BabyIAXO prototype will be shown.

Instruments & Instrumentation↗

A laserball calibration device for the SNO+ scintillator phase

Located 2 km underground in SNOLAB, Sudbury, Canada, SNO+ is a large scale liquid scintillator experiment that primarily aims to search for neutrinoless double beta decay. Whilst SNO+ has light and radioactive calibration sources external to the inner volume, an internally deployed optical source is necessary for the full characterization of the detector model. A laser diffuser ball developed for SNO has previously demonstrated to be an effective optical calibration device for both SNO and SNO+ water phase. Since the introduction of liquid scintillator for SNO+, the material compatibility, cleanliness, and radiopurity requirements of any materials in contact with the internal medium have increased. Improving on the original SNO laserball design, a new laserball calibration device has been developed for the SNO+ scintillator phase with the goal of measuring the optical properties of the detector and performing routine PMT gain and timing calibrations. Simulations have been written to model the diffusion properties to optimise optical and temporal performance for calibration. Prototype laserballs have been built and characterised, demonstrating sub-ns timing resolution and a quasi-isotropic light distribution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status and perspectives of the ICARUS experiment at the Fermilab Short Baseline Neutrino program

In this study, the ICARUS collaboration has employed the 760 t T600 detector in a successful three-year physics run at the underground LNGS laboratory, performing a sensitive search for LSND-like anomalous ν e appearance in the CERN Neutrino to Gran Sasso beam, which contributed to the constraints on the allowed neutrino oscillation parameters to a narrow region around Δm 2 ~ 1 eV 2 . After a significant overhaul at CERN, the T600 detector has been installed at Fermilab. In 2020 the cryogenic commissioning began with detector cool down, liquid Argon filling and recirculation. ICARUS then started its operation collecting the first neutrino events from the Booster Neutrino Beam (BNB) and the Neutrinos at the Main Injector (NuMI) beam off-axis, which were used to test the ICARUS event selection, reconstruction and analysis algorithms. ICARUS successfully completed its commissioning phase in June 2022, moving then to data taking for neutrino oscillation physics, aiming at first to either confirm or refute the claim by Neutrino-4 short-baseline reactor. ICARUS will also jointly search for evidence of sterile neutrinos together with the Short-Baseline Near Detector, within the Fermilab Short-Baseline Neutrino program experiment, and will perform measurements of neutrino cross sections with both beams and several Beyond Standard Model searches with the NuMI beam. In this paper, the main technical achievements of the ICARUS detector subsystems (Time Projection Chambers, Light Detection System, Cosmic Ray Tagger, Trigger and Data Acquisition) obtained with both BNB and NuMI neutrino beams during the commissioning phase, will be presented in terms of the overall detector performance and capability to select and reconstruct neutrino events.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗