Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Transmission”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Duration of tick attachment necessary for transmission of Anaplasma phagocytophilum by Ixodes scapularis (Acari: Ixodidae) nymphs

This study assessed the duration of tick attachment necessary for a successful transmission of Anaplasma phagocytophilum by an infected I. scapularis nymph. Individual nymphs were placed upon BALB/c mice and allowed to feed for predetermined time intervals of 4 to 72 h. Ticks removed from mice at predetermined intervals were tested by PCR for verification of infection and evaluation of the bacterial load. The success of pathogen transmission to mice was assessed by blood-PCR at 7, 14 and 21 days postinfestation, and IFA at 21 days postinfestation. Anaplasma phagocytophilum infection was documented in 10-30 % of mice, from which ticks were removed within the first 20 h of feeding. However, transmission success was ≥70% if ticks remained attached for 36 h or longer. Notably, none of the PCR-positive mice that were exposed to infected ticks for 4 to 8 h and only half of PCR-positive mice exposed for 24 h developed antibodies within 3 weeks postinfestation. On the other hand, all mice with detectable bacteremia after being infested for 36 h seroconverted. This suggests that although some of the ticks removed prior to 24 h of attachment succeed in injecting a small amount of A. phagocytophilum, this amount is insufficient for stimulating humoral immunity and perhaps for establishing disseminated infection in BALB/c mice. Although A. phagocytophilum may be present in salivary glands of unfed I. scapularis nymphs, the amount of A. phagocytophilum initially contained in saliva appears insufficient to cause sustainable infection in a host. Replication and, maybe, reactivation of the agent for 12-24 h in a feeding tick is required before a mouse can be consistently infected.

59 BASIC BIOLOGICAL SCIENCES↗

Three-dimensional infrared metamaterial with asymmetric transmission

A novel three-dimensional (3D) metallic metamaterial structure with asymmetric transmission for linear polarization is demonstrated in the infrared spectral region. The structure was fabricated by direct laser writing and selective electroless silver coating, a straightforward, novel technique producing mechanically and chemically stable 3D photonic structures. The structure unit cell is composed of a pair of conductively coupled magnetic resonators, and the asymmetric transmission response results from interplay of electric and magnetic responses; this equips the structure with almost total opaqueness along one propagation direction versus satisfying transparency along the opposite one. It also offers easily adjustable impedance, 90° one-way pure optical activity and backward propagation possibility, resulting thus in unique capabilities in polarization control and isolation applications. We show also that scaling down the structure can make it capable of exhibiting its asymmetric transmission and its polarization capabilities in the optical region.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Axon-like active signal transmission

Any electrical signal propagating in a metallic conductor loses amplitude due to the natural resistance of the metal. Compensating for such losses presently requires repeatedly breaking the conductor and interposing amplifiers that consume and regenerate the signal. This century-old primitive severely constrains the design and performance of modern interconnect-dense chips. Here we present a fundamentally different primitive based on semi-stable edge of chaos (EOC), a long-theorized but experimentally elusive regime that underlies active (self-amplifying) transmission in biological axons. By electrically accessing the spin crossover in LaCoO 3 , we isolate semi-stable EOC, characterized by small-signal negative resistance and amplification of perturbations. In a metallic line atop a medium biased at EOC, a signal input at one end exits the other end amplified, without passing through a separate amplifying component. While superficially resembling superconductivity, active transmission offers controllably amplified time-varying small-signal propagation at normal temperature and pressure, but requires an electrically energized EOC medium. Operando thermal mapping reveals the mechanism of amplification—bias energy of the EOC medium, instead of fully dissipating as heat, is partly used to amplify signals in the metallic line, thereby enabling spatially continuous active transmission, which could transform the design and performance of complex electronic chips.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Laser-driven ultrafast transmission electron microscopy

Recent advances in lasers and electron optics technology have allowed transmission electron microscopes to achieve high spatial and temporal resolution, making them capable of tracking atoms, charges and spin motions down to the attosecond and nanometre scales. This Primer discusses the most common and practical experimental implementation of time-resolved transmission electron microscopy and the stroboscopic mode for evaluating ultrafast reversible dynamics. An in-depth discussion of photo-induced near-field electron microscopy, a technique unique to laser-assisted electron microscopy, is also provided, covering its prospective applications in the study of coherent phenomena in quantum materials. The experimental strategies and limitations in investigating the structural dynamics of materials and nanostructures by imaging, diffraction and spectroscopy are also described in detail, with a direct comparison with more conventional and established techniques. Here, we provide key information for new researchers who intend to use ultrafast transmission electron microscopy to address new challenges in specific materials science, condensed matter and nanophotonics.

Transmission electron microscopy↗

Measurement placement in electric power transmission and distribution grids: Review of concepts, methods, and research needs

Sensing and measurement systems are quintessential to the safe and reliable operation of electric power grids. Their strategic placement is of ultimate importance because it is not economically viable to install measurement systems on every node and branch of a power grid, though they need to be monitored. An overwhelming number of strategies have been developed to meet oftentimes multiple conflicting objectives. The prime challenge in formulating the problem lies in developing a heuristic or an optimisation model that, though mathematically tractable and constrained in cost, leads to trustworthy technical solutions. Further, large-scale, long-term deployments pose additional challenges because the boundary conditions change as technologies evolve. For instance, the advent of new technologies in sensing and measurement, as well as in communications and networking, might impact the cost and performance of available solutions and shift initially set conditions. Also, the placement strategies developed for transmission grids might not be suitable for distribution grids, and vice versa, because of unique characteristics; therefore, the strategies need to be flexible, to a certain extent, because no two power grids are alike. Despite the extensive literature on the present topic, the focus of published works tends to be on a specific subject, such as the optimal placement of measurements to ensure observability in transmission grids. There is a dearth of work providing a comprehensive picture for developing optimal placement strategies. Because of the ongoing efforts on the modernisation of electric power grids, there is a need to consolidate the status quo while exposing its limitations to inform policymakers, industry stakeholders, and researchers on the research-and-development needs to push the boundaries for innovation. Accordingly, this paper first reviews the state-of-the-art considering both transmission and distribution grids. Then, it consolidates the key factors to be considered in the problem formulation. Finally, it provides a set of perspectives on the measurement placement problem, and it concludes with future research directions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A generating function approach to HIV transmission with dynamic contact rates

The basic reproduction number, R 0 , is often defined as the average number of infections generated by a newly infected individual in a fully susceptible population. The interpretation, meaning, and derivation of R 0 are controversial. However, in the context of mean field models, R 0 demarcates the epidemic threshold below which the infected population approaches zero in the limit of time. In this manner, R 0 has been proposed as a method for understanding the relative impact of public health interventions with respect to disease eliminations from a theoretical perspective. The use of R 0 is made more complex by both the strong dependency of R 0 on the model form and the stochastic nature of transmission. A common assumption in models of HIV transmission that have closed form expressions for R 0 is that a single individual’s behavior is constant over time. For this research, we derive expressions for both R 0 and probability of an epidemic in a finite population under the assumption that people periodically change their sexual behavior over time. We illustrate the use of generating functions as a general framework to model the effects of potentially complex assumptions on the number of transmissions generated by a newly infected person in a susceptible population. In conclusion, we find that the relationship between the probability of an epidemic and R 0 is not straightforward, but, that as the rate of change in sexual behavior increases both R 0 and the probability of an epidemic also decrease.

59 BASIC BIOLOGICAL SCIENCES↗

Transmission of cluster ions through a tandem accelerator of several stripper gases

The transmissions of carbon cluster ion beams through a tandem accelerator using several stripper gases (He, N{sub 2}, CO{sub 2}, and SF{sub 6}) with a terminal voltage of 2.5 MV were measured as a function of the gas pressure in investigating the most suitable gas for cluster ion acceleration. This resulted in it being demonstrated that the highest transmission could be obtained using the smaller size gas, i.e., helium displayed the best performance of the four gases used. In addition, the ratio of transmissions of C{sub n} with helium and nitrogen increased with increases in the n, thus revealing that helium gas should prove the most effective in larger cluster ion acceleration using the same energy.

43 PARTICLE ACCELERATORS↗

Measurement of RF Mode Purity in EC Transmission Test Line for ITER

The transmission mode purity was measured at the ITER relevant transmission line for 170 GHz ECH and CD system. The measured purity of HE{sub 11} in transmission power was 73% and the other was higher order modes. The dominant higher order mode was LP{sub 11} mode (HE{sub 21}+TE{sub 01}). To improve the mode purity, the RF beam coupling in MOU was aligned because LP{sub 11} mode is generated the offset and the tilt angle of RF beam at the waveguide inlet. After the alignment, HE{sub 11} mode purity was increased to 87%.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Narrow-band optical transmission of metallic nanoslit arrays

Metallic nanoslit arrays usually demonstrate wide transmission bands for transverse-magnetic-polarized incidence light. Here, we show that by introducing multi-dielectric layers underneath the metallic structure layer on the substrate, a narrow peak is formed, whose bandwidth can be down to a few nanometers. Three types of resonance modes in the region under the metal layer are identified responsible for the formation of the peak, i.e., a two-dimensional cavity resonance mode, which supports optical transmission, and two in-plane hybrid surface plasmon resonance modes locating on both sides of the peak that suppresses the transmission. Such structures can be applied in advanced photonic devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Correction for dynamic bias error in transmission measurements of void fraction

Dynamic bias errors occur in transmission measurements, such as X-ray, gamma, or neutron radiography or tomography. This is observed when the properties of the object are not stationary in time and its average properties are assessed. The nonlinear measurement response to changes in transmission within the time scale of the measurement implies a bias, which can be difficult to correct for. A typical example is the tomographic or radiographic mapping of void content in dynamic two-phase flow systems. In this work, the dynamic bias error is described and a method to make a first-order correction is derived. A prerequisite for this method is variance estimates of the system dynamics, which can be obtained using high-speed, time-resolved data acquisition. However, in the absence of such acquisition, a priori knowledge might be used to substitute the time resolved data. Using synthetic data, a void fraction measurement case study has been simulated to demonstrate the performance of the suggested method. The transmission length of the radiation in the object under study and the type of fluctuation of the void fraction have been varied. Significant decreases in the dynamic bias error were achieved to the expense of marginal decreases in precision.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lens transmission measurement for an absolute radiation thermometer

The lens transmission for the National Institute of Metrology of China absolute radiation thermometer is measured by a hybrid method. The results of the lens transmission measurements are 99.002% and 86.792% for filter radiometers with center wavelengths 633 nm and 900 nm, respectively. These results, after correcting for diffraction factors and the size-of-source effect when the lens is incorporated within the radiometer, can be used for measurement of thermodynamic temperature. The expanded uncertainty of the lens transmission measurement system has been evaluated. It is 1.3×10{sup −3} at 633 nm and 900 nm, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Polarization dependent color switching by extra-ordinary transmission in H-slit plasmonic metasurface

An array of H-shaped subwavelength slits in a plasmonic film has a polarization dependent extra-ordinary transmission due to shape anisotropy. Non-overlapping extra-ordinary transmission bands for the orthogonal linear polarization states of the input light are used to demonstrate a polarization dependent color switch. The fabricated array of submicron sized H-slits on a gold film displayed two transmission bands for the linear x- and y-polarized light at visible (650–850 nm) and near-infra-red (1150–1450 nm) bands, respectively. The relative transmitted light in these two bands can be controlled by changing the linear polarization state of the input radiation from 0° to 90°.

36 MATERIALS SCIENCE↗

Even-odd oscillation and valley polarization of transmission between multilayer graphenes

Electron transmission through a boundary between multi-layer graphenes with Bernal stacking consisting of different number of layers is studied. A valley polarization in transmission probability appears as in monolayer and bilayer systems, exhibits considerable oscillation depending of even or odd layer numbers, and its amplitude gradually decreases with the layer number. The total transmission shows oscillation with much smaller amplitude.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Bias-field controlled phasing and power combination of gyromagnetic nonlinear transmission lines

Gyromagnetic Nonlinear Transmission Lines (NLTLs) generate microwaves through the damped gyromagnetic precession of the magnetic moments in ferrimagnetic material, and are thus utilized as compact, solid-state, frequency agile, high power microwave (HPM) sources. The output frequency of a NLTL can be adjusted by control of the externally applied bias field and incident voltage pulse without physical alteration to the structure of the device. This property provides a frequency tuning capability not seen in many conventional e-beam based HPM sources. The NLTLs developed and tested are mesoband sources capable of generating MW power levels in the L, S, and C bands of the microwave spectrum. For an individual NLTL the output power at a given frequency is determined by several factors including the intrinsic properties of the ferrimagnetic material and the transmission line structure. Hence, if higher power levels are to be achieved, it is necessary to combine the outputs of multiple NLTLs. This can be accomplished in free space using antennas or in a transmission line via a power combiner. Using a bias-field controlled delay, a transient, high voltage, coaxial, three port, power combiner was designed and tested. Experimental results are compared with the results of a transient COMSOL simulation to evaluate combiner performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Conditions for reflection and transmission of an ion acoustic soliton in a dusty plasma with variable charge dust

Modified Korteweg-de Vries (mKdV) equations are derived for the incident, reflected, and transmitted waves in order to examine the soliton reflection and its transmission through an inhomogeneous plasma comprising ions, dust grains with fluctuating charge and two types of electrons, namely nonisothermal electrons and isothermal electrons. All the mKdV equations are coupled at the point of reflection and solved for the reflected soliton. Unlike others, a relation is established between the velocity shifts of the incident, reflected and transmitted solitons, and based on a critical value of the shift of incident soliton the strengths of the soliton reflection and transmission are talked about. Conditions are obtained for the soliton reflection and its transmission, and a comparative study is made for the two cases of fixed and fluctuating charges on the dust grains.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Broadband asymmetric acoustic transmission by a plate with quasi-periodic surface ridges

In this paper, an acoustic system with broadband asymmetric transmission is designed and fabricated, which consists of a water-immersed aluminum plate engraved with quasi-periodically-patterned ridges on single surface. It demonstrates that when the acoustic waves are launched into the system from the structured side, they can couple into the Lamb modes in the plate efficiently and attain a high transmission; on the contrary, when the waves are incident from the opposite flat side, the coupling is weak, and the transmission is low. Superior to systems with periodic patterning, this quasi-periodically-patterned system has a broad working frequency range due to the collective contributions from the multiple diffractions specific to the structure.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Study on Zeeman-split spoof surface plasmon polaritons by use of spin-sensitive enhanced electromagnetic transmission

Structured metal surfaces could support spoof surface plasmon polaritons (SPPs), the dispersion of which is determined by the cutoff condition of guided modes in the nanostructures. We show that we can achieve split spoof SPPs by breaking the degeneracy of guided helical modes in concentric nanostructures via the classic analogue of the Zeeman effect. This split effect is shown to be observable from the spectra of enhanced electromagnetic transmission. Spin-sensitive enhanced electromagnetic transmission and the associated characteristics of field are investigated. Transmission branches versus parallel wavevector can be satisfactorily fitted by using the dispersion of spoof SPPs.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Extraordinary reflection and transmission with direction dependent wavelength selectivity based on parity-time-symmetric multilayers

In this paper, we present a kind of periodical ternary parity-time (PT) -symmetric multilayers to realize nearly 100% reflectance and transmittance simultaneously when light is incident from a certain direction. This extraordinary reflection and transmission is original from unidirectional Bragg reflection of PT-symmetric systems as the symmetry spontaneous breaking happens at PT thresholds. The extra energy involved in reflection and transmission lights is obtained from pumping light to the gain regions of the structure. Moreover, we find that our PT-symmetric structure shows direction dependent wavelength selectivity. When the illumination light is incident from two opposite directions into the multilayer structure, such extraordinary reflection and transmission appear at visible and near-infrared wavelengths, respectively. Such distinguishing properties may provide these structures with attractive applications as beam splitters, laser mirrors, narrow band filters, and multiband PT-symmetric optical devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗