Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Transducers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Apparatus for determining changes in limb volume

Measuring apparatus for determining changes in the volume of limbs or other boty extremities by determining the cross-sectional area of such limbs many comprise a transmitter including first and second transducers for positioning on the surface of the limb at a predetermined distance there between, and a receiver including a receiver crystal for positioning on the surface of the limb. The distance between the receiver crystal and the first and second transducers are represented by respective first and second chords of the cross-section of the limb and the predetermined distance between the first and second transducers is represented by a third chord of the limb cross section.

Bhagat, P. K.↗

Fluctuating pressure measurements on the fan blades of a turbofan engine during ground and flight tests

As part of a program to investigate fan noise generated by a turbofan engine, miniature pressure transducers were used to measure the fluctuating pressures on the surface of a fan blade on the JT15D engine. Tests were conducted on the ground, with tunnel and in flight. Using narrowband spectra analysis and signal enhancement techniques, comparisons for these various test conditions are presented. Results on the blade pressures are also presented from a flight test in which 41 rods were placed in front of the fan face to excite a known spinning mode in the duct. Results showed that with care, ground tests can be conducted in which the pressure loading on the blades are similar to those in flight. Comparison of pressure transducers on the blade surface also showed that a single transducer would provide much of the information available from this type of measurement.

Schoenster, J. A.↗

Effects of specimen resonances on acoustic-ultrasonic testing

Frequency response is studied at two different transducer locations in the 10-280 kHz range, for the case of the response of a solid 6061-T6 aluminum alloy block to the fracture of an 0.5 mm-diameter pencil lead, as well as to the impact of 0.159 and 0.318 cm-diameter stainless steel spheres. Prominent peaks in the pencil lead fracture and sphere impact spectra from the two transducer locations are found to exactly correspond to the alloy block's resonant frequencies, indicating that these have dominated the spectral content of the output signal. The spectral content is further influenced by the transducer location, relative to the resonant frequency nodal lines. The implications of these results for acoustic-ultrasonic parameters and measurements are discussed.

Williams, J. H., Jr.↗

On archaebacterial ATPase from Halobacterium saccharovorum

The energy transducing ATPase from Halobacterium saccharovorum was studied in order to define the origin of energy transducing systems. The ATPase required high salt concentration (4M NaCl) for activity; activity was rapidly lost when NaCl was below 1 Molar. At low salt concentration, the membrane bound ATPase activity could be stabilized in presence of spermine. However, following solubilization spermine was ineffective. Furthermore, F1 ATPase activity was stabilized by ammonium sulfate even when the NaCl concentration was less than 1 Molar. These studies suggest that stabilization by hydrophobic interactions preceded ionic ones in the evolution of the energy transducing ATPases.

Kristjansson, H.↗

The use of an optical data acquisition system for bladed disk vibration analysis

A new concept in instrumentation was developed by engineers at NASA Lewis Research Center to collect vibration data from multi-bladed rotors. This new concept, known as the optical data acquisition system, uses optical transducers to measure bladed tip delections by reflection light beams off the tips of the blades as they pass in front of the optical transducer. By using an array of transducers around the perimeter of the rotor, detailed vibration signals can be obtained. In this study, resonant frequencies and mode shapes were determined for a 56 bladed rotor using the optical system. Frequency data from the optical system was also compared to data obtained from strain gauge measurements and finite element analysis and was found to be in good agreement.

Lawrence, C.↗

Measurement of ultrasonic fields in transparent media using a scanning differential interferometer

An experimental system for the detection of three dimensional acoustic fields in optically transparent media using a dual beam differential interferometer is described. In this system, two coherent, parallel, focused laser beams are passed through the specimen and the interference fringe pattern which results when these beams are combined shifts linearly by an amount which is related to the optical pathlength difference between the two beams. It is shown that for small signals, the detector output is directly proportional to the amplitude of the acoustic field integrated along the optical beam path through the specimen. A water tank and motorized optical platform were constructed to allow these dual beams to be scanned through an ultrasonic field generated by a piezoelectric transducer at various distances from the transducer. Scan data for the near, Fresnel, and far zones of a uniform, circular transducer are presented and an algorithm for constructing the radial field profile from this integrated optical data, assuming cylindrical symmetry, is described.

Dockery, G. D.↗

Analytical ultrasonics for evaluation of composite materials response. Part 1: Physical interpretation

The phenomena associated with the propagation of elastic waves in anisotropic materials are discussed. Wave modes propagating in general directions relative to the material coordinate system are not purely longitudinal nor transverse. Hence the generation of ultrasonic waves by common piezoelectric transducers will generate multiple modes to some extent. The received signals will likely be a combination of different modes. When using two transducers to send and receive ultrasonic waves, deviation of the energy flux vector may reduce the apparent value of the received signal unless the proper orientation of the two transducers with respect to one another is taken into account. And application of reflection from plane boundaries for the purposes of making certain measurements may lead to misinterpretation of results unless one is aware of the differences in multiple mode generation and critical angle phenomena between isotropic and anisotropic materials. When studies or characterizations of composite materials by ultrasonics are to be performed, these phenomena must be taken into consideration so that proper and correct application and interpretation of the measurements can be made. Finally, attention must be drawn again to the fact that composite materials are heterogeneous by definition. The results discussed here have been determined for homogeneous materials only. While the assumption of homogeneity appears to be valid for certain wavelength ranges in composites, future work must continue to study the phenomena of wave propagation in anisotropic, nonhomogeneous materials.

Henneke, E. G., II↗

The use of an optical data acquisition system for bladed disk vibration analysis

A new concept in instrumentation was developed by engineers at NASA Lewis Research Center to collect vibration data from multi-bladed rotors. This new concept, known as the optical data acquisition system, uses optical transducers to measure bladed tip deflections by reflection of light beams off the tips of the blades as they pass in front of the optical transducer. By using an array of transducers around the perimeter of the rotor, detailed vibration signals can be obtained. In this study, resonant frequencies and mode shapes were determined for a 56 bladed rotor using the optical system. Frequency data from the optical system was also compared to data obtained from strain gauge measurements and finite element analysis and was found to be in good agreement.

Lawrence, C.↗

An Investigation of Energy Transmission Due to Flexural Wave Propagation in Lightweight, Built-Up Structures

A technique to measure flexural structure-borne noise intensity is investigated. Two accelerometers serve as transducers in this cross-spectral technique. The structure-borne sound power is obtained by two different techniques and compared. In the first method, a contour integral of intensity is performed from the values provided by the two-accelerometer intensity technique. In the second method, input power is calculated directly from the output of force and acceleration transducers. A plate and two beams were the subjects of the sound power comparisons. Excitation for the structures was either band-limited white noise or a deterministic signal similar to a swept sine. The two-accelerometer method was found to be sharply limited by near field and transducer spacing limitations. In addition, for the lightweight structures investigated, it was found that the probe inertia can have a significant influence on the power input to the structure. In addition to the experimental investigation of structure-borne sound energy, an extensive study of the point harmonically forced, point-damped beam boundary value problem was performed to gain insight into measurements of this nature. The intensity formulations were also incorporated into the finite element method. Intensity mappings were obtained analytically via finite element modeling of simple structures.

Mickol, John Douglas↗

Improved acoustic emission locations

A technique for locating acoustic emission in brittle rock specimens is described. An array of eight piezoelectric transducers was used to detect acoustic emission and to receive velocity measurement pulses. Axial and transverse velocities were calculated from the transmission data; the use of the velocity data to locate the acoustic emissions is discussed. Waveforms were recorded for about 140 acoustic emissions during the deformation of the Westerly granite specimen and about 100 acoustic emissions were located. The effect of transducer size and incident angle on apparent arrival times is evaluated using a lead zirconium titinate transducer bonded to a small brass rider with a curved surface matched to the brass specimen. The relation between location accuracy in various regions of the specimen and the geometry of the receiver array is studied. It is observed that for incidence angles away from the normal, the velocity appears to be higher than for normal incidences.

Getting, I. C.↗

Measuring Fan-Blade-Tip Displacements

Magnets and Hall-effect transducers used to monitor tip-to-shroud clearances. Mounting permanent magnet in end of fan blade and monitoring tip-to-shroud distance by use of output of Hall-effect transducers affixed to surface of shroud. Transducers provide real-time information. By placing magnets in each fan-blade tip, complete set monitored sequentially as each blade rotates past sensor. Application in many rotating machines, providing surrounding materials nonmagnetic and temperatures not severe.

Berry, Robert F., Jr.↗

A new method for acoustic containerless processing of materials

The development of an acoustic positioner, which uses only one acoustic mode in chambers of rectangular, cylindrical, and spherical geometries, for high-temperature containerless processing of materials in space is described. The objective of the single-mode positioner is to develop sufficient acoustic forces to stably localize and manipulate molten materials. In order to attain this goal the transducer power, energy transfer medium, and chamber geometry and dimensions need to be optimized. The use of a variable frequency compression driver or solid-state piezoelectric transducer to optimize these properties is investigated; it is determined that a solid-state transducer would be most applicable for optimizing the positioner. The positioning capabilities of this single-mode positioner are discussed. The dependence of the acoustic forces on temperature and ambient pressure is studied. The development of a levitator to process a molten sample at 1500 C in the space environment using the cylindrical (011) mode is illustrated.

Barmatz, M.↗

Independent Orbiter Assessment (IOA): Analysis of the elevon subsystem

The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA approach features a top-down analysis of the hardware to determine failure modes, criticality, and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. This report documents the independent analysis results for the Orbiter Elevon system hardware. The elevon actuators are located at the trailing edge of the wing surface. The proper function of the elevons is essential during the dynamic flight phases of ascent and entry. In the ascent phase of flight, the elevons are used for relieving high wing loads. For entry, the elevons are used to pitch and roll the vehicle. Specifically, the elevon system hardware comprises the following components: flow cutoff valve; switching valve; electro-hydraulic (EH) servoactuator; secondary delta pressure transducer; bypass valve; power valve; power valve check valve; primary actuator; primary delta pressure transducer; and primary actuator position transducer. Each level of hardware was evaluated and analyzed for possible failure modes and effects. Criticality was assigned based upon the severity of the effect for each failure mode. Of the 25 failure modes analyzed, 18 were determined to be PCIs.

Wilson, R. E.↗

Compensating for pneumatic distortion in pressure sensing devices

A technique of compensating for pneumatic distortion in pressure sensing devices was developed and verified. This compensation allows conventional pressure sensing technology to obtain improved unsteady pressure measurements. Pressure distortion caused by frictional attenuation and pneumatic resonance within the sensing system makes obtaining unsteady pressure measurements by conventional sensors difficult. Most distortion occurs within the pneumatic tubing which transmits pressure impulses from the aircraft's surface to the measurement transducer. To avoid pneumatic distortion, experiment designers mount the pressure sensor at the surface of the aircraft, (called in-situ mounting). In-situ transducers cannot always fit in the available space and sometimes pneumatic tubing must be run from the aircraft's surface to the pressure transducer. A technique to measure unsteady pressure data using conventional pressure sensing technology was developed. A pneumatic distortion model is reduced to a low-order, state-variable model retaining most of the dynamic characteristics of the full model. The reduced-order model is coupled with results from minimum variance estimation theory to develop an algorithm to compensate for the effects of pneumatic distortion. Both postflight and real-time algorithms are developed and evaluated using simulated and flight data.

Whitmore, Stephen A.↗

Experiments on active control of vibrational power flow using piezoceramic actuators and sensors

The active control of flexural power flow in both semiinfinite and finite elastic beams is experimentally investigated. The experimental results demonstrate that piezoceramic transducers when used in conjunction with an adaptive least mean squares controller, can effectively control flexural power flow in thin beam systems. The piezoceramic transducers offer distinct size and weight advantages over conventional transducers. The experiments also demonstrate the use of an axial scanning laser vibrometer to determine out of plane velocity and power flow.

Gibbs, Gary P.↗

Prototype of a magnetically suspended flywheel energy storage system

The authors describe recent progress in the development of a 500-Wh magnetically suspended flywheel stack energy storage system. The design of the system and a critical study of the noncontacting displacement transducers and their placement in the stack system are discussed. The storage system has been designed and constructed and is currently undergoing experimental analysis. The results acquired from the noncontacting displacement transducer study show that currently available transducers will not function as desired and that further research is essential.

Plant, David P.↗

A novel electron tunneling infrared detector

The pneumatic infrared detector, originally developed by Golay in the late 1940s, uses the thermal expansion of one cm(exp 3) of xenon at room temperature to detect the heat deposited by infrared radiation. This detector was limited by thermal fluctuations within a 10 Hz bandwidth, but suffered from long thermal time constants and a fragile structure. Nevertheless, it represents the most sensitive room temperature detector currently available in the long wavelength infrared (LWIR). Fabrication of this type of detector on smaller scales has been limited by the lack of a suitably sensitive transducer. Researchers designed a detector based on this principle, but which is constructed entirely from micromachined silicon, and uses a vacuum tunneling transducer to detect the expansion of the trapped gas. Because this detector is fabricated using micromachining techniques, miniaturization and integration into one and two-dimensional arrays is feasible. The extreme sensitivity of vacuum tunneling to changes in electrode separation will allow a prototype of this detector to operate in the limit of thermal fluctuations over a 10 kHz bandwidth. A calculation of the predicted response and noise of the prototype is presented with the general formalism of thermal detectors. At present, most of the components of the prototype have been fabricated and tested independently. In particular, a characterization of the micromachined electron tunneling transducer has been carried out. The measured noise in the tunnel current is within a decade of the limit imposed by shot noise, and well below the requirements for the operation of an infrared detector with the predicted sensitivity. Assembly and characterization of the prototype infrared detector will be carried out promptly.

Kenny, T. W.↗

Rapidly quantifying the relative distention of a human bladder

A device and method was developed to rapidly quantify the relative distention of the bladder of a human subject. An ultrasonic transducer is positioned on the human subject near the bladder. A microprocessor controlled pulser excites the transducer by sending an acoustic wave into the human subject. This wave interacts with the bladder walls and is reflected back to the ultrasonic transducer where it is received, amplified, and processed by the receiver. The resulting signal is digitized by an analog to digital converter, controlled by the microprocessor again, and is stored in data memory. The software in the microprocessor determines the relative distention of the bladder as a function of the propagated ultrasonic energy. Based on programmed scientific measurements and the human subject's past history as contained in program memory, the microprocessor sends out a signal to turn on any or all of the available alarms. The alarm system includes and audible alarm, the visible alarm, the tactile alarm, and the remote wireless alarm.

Companion, John A.↗