Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Thermal testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Mars Exploration Rover Entry, Descent, and Landing: A Thermal Perspective

Perhaps the most challenging mission phase for the Mars Exploration Rovers was the Entry, Descent, and Landing (EDL). During this phase, the entry vehicle attached to its cruise stage was transformed into a stowed tetrahedral Lander that was surrounded by inflated airbags through a series of complex events. There was only one opportunity to successfully execute an automated command sequence without any possible ground intervention. The success of EDL was reliant upon the system thermal design: 1) to thermally condition EDL hardware from cruise storage temperatures to operating temperature ranges; 2) to maintain the Rover electronics within operating temperature ranges without the benefit of the cruise single phase cooling loop, which had been evacuated in preparation for EDL; and 3) to maintain the cruise stage propulsion components for the critical turn to entry attitude. Since the EDL architecture was inherited from Mars Pathfinder (MPF), the initial EDL thermal design would be inherited from MPF. However, hardware and implementation differences from MPF ultimately changed the MPF inheritance approach for the EDL thermal design. With the lack of full inheritance, the verification and validation of the EDL thermal design took on increased significance. This paper will summarize the verification and validation approach for the EDL thermal design along with applicable system level thermal testing results as well as appropriate thermal analyses. In addition, the lessons learned during the system-level testing will be discussed. Finally, the in-flight EDL experiences of both MER-A and -B missions (Spirit and Opportunity, respectively) will be presented, demonstrated how lessons learned from Spirit were applied to Opportunity.

thermal↗

Correlation between Mechanical Behavior and Actuator-type Performance of Ni-Ti-Pd High-temperature Shape Memory Alloys

High-temperature shape memory alloys in the NiTiPd system are being investigated as lower cost alternatives to NiTiPt alloys for use in compact solid-state actuators for the aerospace, automotive, and power generation industries. A range of ternary NiTiPd alloys containing 15 to 46 at.% Pd has been processed and actuator mimicking tests (thermal cycling under load) were used to measure transformation temperatures, work behavior, and dimensional stability. With increasing Pd content, the work output of the material decreased, while the amount of permanent strain resulting from each load-biased thermal cycle increased. Monotonic isothermal tension testing of the high-temperature austenite and low temperature martensite phases was used to partially explain these behaviors, where a mismatch in yield strength between the austenite and martensite phases was observed at high Pd levels. Moreover, to further understand the source of the permanent strain at lower Pd levels, strain recovery tests were conducted to determine the onset of plastic deformation in the martensite phase. Consequently, the work behavior and dimensional stability during thermal cycling under load of the various NiTiPd alloys is discussed in relation to the deformation behavior of the materials as revealed by the strain recovery and monotonic tension tests.

Bigelow, Glen S.↗

Computational Modeling Develops Ultra-Hard Steel

Glenn Research Center's Mechanical Components Branch developed a spiral bevel or face gear test rig for testing thermal behavior, surface fatigue, strain, vibration, and noise; a full-scale, 500-horsepower helicopter main-rotor transmission testing stand; a gear rig that allows fundamental studies of the dynamic behavior of gear systems and gear noise; and a high-speed helical gear test for analyzing thermal behavior for rotorcraft. The test rig provides accelerated fatigue life testing for standard spur gears at speeds of up to 10,000 rotations per minute. The test rig enables engineers to investigate the effects of materials, heat treat, shot peen, lubricants, and other factors on the gear's performance. QuesTek Innovations LLC, based in Evanston, Illinois, recently developed a carburized, martensitic gear steel with an ultra-hard case using its computational design methodology, but needed to verify surface fatigue, lifecycle performance, and overall reliability. The Battelle Memorial Institute introduced the company to researchers at Glenn's Mechanical Components Branch and facilitated a partnership allowing researchers at the NASA Center to conduct spur gear fatigue testing for the company. Testing revealed that QuesTek's gear steel outperforms the current state-of-the-art alloys used for aviation gears in contact fatigue by almost 300 percent. With the confidence and credibility provided by the NASA testing, QuesTek is commercializing two new steel alloys. Uses for this new class of steel are limitless in areas that demand exceptional strength for high throughput applications.

Source record↗

Thermal modeling of absorber-coupled TES polarimeter.

Using experimental thermal conductivity and volume heat capacity of narrow silicon nitride beams obtained from thermal test structures and a boundary limited phonon scattering model, as well as the heat conduction equation, we analyze the thermal performance of an absorber-coupled TES polarimeter with finite element method. The polarimeter's temperature distribution, thermal power readout efficiency, and time constant are calculated. The thermal power readout efficiency of the polarimeter is up to 87% at a low signal modulation frequency, and has a 0.5 dB attenuation at 120 Hz. We also compare a preliminary optical testing result with theoretical expectation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Workflow to Optimize Fast Neutron Irradiation in A Thermal Neutron Spectrum Test Reactor Leveraging Open-Source Tools

The Advanced Test Reactor (ATR) located at Idaho National Laboratory (INL) is one of the key nuclear engineering research and testing facilities within the US Department of Energy (DOE). The ATR is one of few high-power research reactors in the world with different application including accelerated testing of nuclear fuel, materials irradiation in a very high neutron flux environment, and medical radioisotope production [1]. Also, the ATR offers opportunities for testing fast spectrum fission and fusion reactor materials. The key challenges in this area are in further detailing and optimizing a fast spectrum environment within a thermal test reactor. This challenge involves researching, developing, and testing novel concepts for the multiplying of neutron populations into ever higher energy spectra in high flux test reactors like ATR. The main objective of this work is to investigate candidate materials for establishing a fast neutron experiment irradiation in thermal neutron spectrum test reactors which can be accomplished by filtering thermal and epithermal neutrons and boosting fast neutrons at designated irradiation positions. However, adding these filters will render the neutron spectrum and the criticality of the system. The selection of the thickness and material layers should be accomplished by developing an optimization design algorithm that is applicable for ATR to enhance the fast neutron spectrum irradiation utilizing high-fidelity Monte Carlo methods along with advanced machine learning capabilities. This paper presents workflow for design optimization to enhance fast neutron irradiation in the ATR. The workflow leverages open-source tools to develop an algorithm that is viable to ATR and can be leveraged in other reactors. The following sections discuss the development of the experiment design optimization workflow and its application to ATR irradiation positions.

42 - ENGINEERING↗

Design and fabrication of titanium multi-wall Thermal Protection System (TPS) test panels

A titanium multiwall thermal protection system panel was designed. The panel is a nine sheet sandwich structure consisting of an upper and lower face sheet; four dimpled sheets, three septum sheets, and clips for attachment to a vehicle structure. An acceptable fabrication process was developed, and the panel design was verified through mechanical and thermal testing of component specimens. A design was completed which takes into consideration fabrication techniques, thermal properties, mechanical properties, and materials availability.

Blair, W.↗

Temperature Stability and Control Requirements for Thermal Vacuum/Thermal Balance Testing of the Aquarius Radiometer

The paper describes the specific temperature stability and control requirements for the thermal vacuum and thermal balance testing of the Aquarius Instrument at the Goddard Space Flight Center in Greenbelt, Maryland. The testing was conducted in the 10' wide x 15' deep Facility 225 Thermal Vacuum chamber. The temperature control stability requirements were less than .14 C RMS thermal variation over a seven-day period. The thermal test specification also called for the ability to impose a high-resolution sinusoidal variation for all heater zones. The special requirements of the Aquarius radiometer test necessitated the construction of a multi-function test fixture and the modification of two existing heater controller racks.

Johnson, Chris↗

Shuttle and Transfer Orbit Thermal Analysis and Testing of the Chandra X-Ray Observatory Charge-Couple Device Imaging Spectrometer Radiator Shades

Thermal analyses of the Shuttle and Transfer Orbit of the Advanced X-Ray Astrophysics Facility Charge-Coupled Device (CCD) Imaging Spectrometer (ACIS), one of two science instruments on the Chandra X-Ray Observatory, revealed a low-earth orbit (LEO) overheating problem on the goldized Kapton faces of two radiator shades. The shades were coated with the goldized Kapton to provide a low hemispherical emittance to minimize direct and backloaded heating from the sun and the observatory and high specularity to optimize the coupling to space on two passive radiators which cool the focal plane to -120 C +/- 1 C during on-orbit operations. Since the observatory has a highly elliptical final orbit of 10,000 kilometers by 140,000 kilometers and the ACIS radiators and shades are oriented anti-sun, the high solar absorptance to emittance ratio of the goldized Kapton was not an issue. However, during Shuttle bay-to-earth operations, the short duration solar heating occurring near the eclipse entry and exit resulted in shade temperatures in excess of the cure temperature of the adhesive used to bond the goldized Kapton and honeycomb face-sheets. The detailed thermal analysis demonstrating the LEO overheating as well as the redesign options and thermal testing of a redesigned development unit shade are presented.

Sharp, John R.↗

DACS II - A distributed thermal/mechanical loads data acquisition and control system

A distributed data acquisition and control system has been developed for the NASA Flight Loads Research Facility. The DACS II system is composed of seven computer systems and four array processors configured as a main computer system, three satellite computer systems, and 13 analog input/output systems interconnected through three independent data networks. Up to three independent heating and loading tests can be run concurrently on different test articles or the entire system can be used on a single large test such as a full scale hypersonic aircraft. Thermal tests can include up to 512 independent adaptive closed loop control channels. The control system can apply up to 20 MW of heating to a test specimen while simultaneously applying independent mechanical loads. Each thermal control loop is capable of heating a structure at rates of up to 150 F per second over a temperature range of -300 to +2500 F. Up to 64 independent mechanical load profiles can be commanded along with thermal control. Up to 1280 analog inputs monitor temperature, load, displacement and strain on the test specimens with real time data displayed on up to 15 terminals as color plots and tabular data displays. System setup and operation is accomplished with interactive menu-driver displays with extensive facilities to assist the users in all phases of system operation.

Zamanzadeh, Behzad↗

Thermal Hydraulic Experimental Test Article (FY2020 Status Report)

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that will be used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility will simulate nominal conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field will be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility is being designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary and secondary system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. Figure 1 illustrates the main components of the primary system. THETA will be installed in the Mechanisms Engineering Test Loop (METL) with the primary system in the 28 inch Test Vessel #4, Figure 2. The design work for the facility has been completed. Since the FY19 THETA status report, the THETA primary system components have been assembled and tested using de-ionized water. Some results of this testing at select Richardson and Reynolds numbers are included herein. The custom THETA sodium flowmeter (permanent magnet submersible sodium flowmeter) has been built and calibrated using sodium in an auxiliary facility against a NIST traceable vortex shedder type flowmeter. The permanent magnet flowmeter showed excellent performance, following the theoretical equation for measured voltage quite well, with an error < 3.5% at flow rates ranging from 3-24 GPM at temperatures up to 400 °C. The secondary sodium system for heat rejection from intermediate heat exchanger has been analyzed according to ASME code. All secondary side piping, fittings and a U-stamped air-to-sodium heat exchanger have been procured.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Thermal Hydraulic Experimental Test Article (FY21 Final Report)

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that will be used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility will simulate nominal conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field will be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility is being designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary and secondary system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. Figure 1 illustrates the main components of the primary system. THETA has been installed in the Mechanisms Engineering Test Loop (METL) with the primary system in the 28 inch Test Vessel #4, Figure 2 and Figure 3. Since the FY20 THETA status report, further water shakedown testing was performed, some final welding modifications were performed, all system components were sanitized, dry assembled, and commissioned. The THETA submersible electromagnetic flowmeter was welded closed to hermetically seal internal components from sodium followed by a helium leak check for the final time. Following installation of THETA into vessel #4, all data acquisition and control systems were brought online and commissioned at room temperature in the argon gas space of the empty vessel. The vessel zone 1 heaters were reinstalled and the flange was then insulated. The vessel 4 heaters were brought to a temperature of 100 °C and the THETA pump was jogged at 600 RPM to ensure it was functioning correctly. The secondary, AC Conduction based electromagnetic pump from CMI Novacast (product number CA-15) was ordered and will be delivered in late calendar year 2021. The custom designed permanent magnet based secondary flowmeter was designed, a drawing package and manufacturing specification created and quote requested from a machine shop. The intermediate heat exchanger design was completed and a drawing package is currently in progress. During the middle of calendar year 2021 the Building 308 sodium scrubber system was shut down in order to replaced some corroded piping and facilitate improvements on the system, thus requiring the sodium in METL to remain frozen. This has imposed a delay in filling vessel 4 with sodium to begin THETA testing. Sodium testing is expected to begin in early fiscal year 2022 as all THETA primary systems are operational.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Maximizing Thermal Efficiency and Optimizing Energy Management [Fact Sheet]

Researchers at the Thermal Test Facility (TTF) on the campus of the U.S. Department of Energy's National Renewable Energy Laboratory (NREL) in Golden, Colorado, are addressing maximizing thermal efficiency and optimizing energy management through analysis of efficient heating, ventilating, and air conditioning (HVAC) strategies, automated home energy management (AHEM), and energy storage systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Toward Autonomous Field Inspection of CSP Collectors With a Polarimetric Imaging Drone

We developed a polarimetric imaging drone to perform field inspections of heliostats and carried out field tests at Sandia’s National Solar Thermal Test Facility (NSTTF). The preliminary results show that Degree of Linear Polarization (DOLP) and Angle of Polarization (AOP) images greatly enhanced the edge detection results compared with the conventional visible images, supporting fast and accurate detection of heliostat mirror edges and cracks. The system holds the promise to enable future automated detection of heliostats optical errors and mirror defects.

14 SOLAR ENERGY↗

Development of a composite repair and the associated inspection intervals for the F-111C stiffener runout region

This paper presents an overview of the structural aspects of the design and development of a local reinforcement designed to lower the stresses in a region of the F-111C wing fitting which is prone to cracking. The stress analysis, with particular emphasis on the use of a unified constitutive model for the cyclic inelastic response of the structure, representative specimen testing, thermal analysis and full scale static testing of this design are summarized.

Jones, R.↗

Conceptual approach study 200 watt per kilogram solar array, phase 3

Activities are described that were directed by JPL to support the earlier conceptual design work with proof of concept models on the one hand, and laboratory test and evaluation of alternate designs and materials that hold promise for further mass economies, on the other. In support of this advanced solar blanket technology the following work was accomplished: (1) preparation of an 80 cell solar module for a 1000 cycle thermal test (2) fabrication of a 660 cell solar panel and performance evaluation of this article after a '0' g flight test, (3) design improvement of the cell interconnect for further mass reduction, (4) completion of UV exposure and thermal cycle tests for a variety of cell cover material and adhesives and (5) preparation of a quantity of representative solar array test specimens for space flight on NASA's Long Duration Exposure Facility (LDEF).

Rayl, G. J.↗

Testing Lunar Return Thermal Protection Systems using Sub-Scale Flight Test Vehicles

A key objective of NASA's Vision for Space Exploration is to revisit the lunar surface. Such an ambitious goal requires the development of a new human-rated spacecraft, the Orion Crew Exploration Vehicle (CEV), to ferry crews to low earth orbit and to the moon. The successful conclusion of both types of missions will require a thermal protection system (TPS) capable of protecting the vehicle and crew from the extreme heat of atmospheric reentry. As a part of the TPS development, various materials are being tested in arcjet tunnels; however, the combined lunar return aerothermal environment of high heat flux, shear stress, and surface pressure cannot be duplicated using only existing ground test facilities. To ensure full TPS qualification, a flight test program using sub-scale Orion capsules has been proposed to test TPS materials and heat shield construction techniques under the most stressing combination of lunar return aerothermal environments. Originally called Testing Of Reentry Capsule Heat Shield, or TORCH, but later renamed LEX, for Lunar Reentry Experiment, the proposed flight test program is presented along with the driving requirements and descriptions of the vehicle and the TPS instrumentation suite slated to conduct in-flight measurements.

heatshield↗

Testing and modeling of diffusion bonded prototype optical windows under ITER conditions

Glass-metal joints are a part of ITER optical diagnostics windows. These joints must be leak tight for the safety (presence of tritium in ITER) and to preserve the vacuum. They must also withstand the ITER environment: temperatures up to 220 deg.C and fast neutron fluxes of {approx}3.10{sup 9} n/cm{sup 2}.s. At the moment, little information is available about glass-metal joints suitable for ITER. Therefore, we performed mechanical and thermal tests on some prototypes of an aluminium diffusion bonded optical window. Finite element modeling with Abaqus code was used to understand the experimental results. The prototypes were helium leaking probably due to very tiny cracks in the interaction layer between the steel and the aluminium. However, they were all able to withstand a thermal cycling test up to 200 deg. C; no damage could be seen after the tests by visual inspection. The prototypes successfully passed push-out test with a 500 N load. During the destructive push-out tests the prototypes broke at a 6-12 kN load between the aluminium layer and the steel or the glass, depending on the surface quality of the glass. The microanalysis of the joints has also been performed. The finite element modeling of the push-out tests is in a reasonable agreement with the experiments. According to the model, the highest thermal stress is created in the aluminium layer. Thus, the aluminium joint seems to be the weakest part of the prototypes. If this layer is improved, it will probably make the prototype helium leak tight and as such, a good ITER window candidate. (authors)

42 ENGINEERING↗

Thermal Property Estimation of Fibrous Insulation: Heat Transfer Modeling and the Continuous Genetic Algorithm

Thermal properties of high-temperature fibrous insulation materials were estimated from transient thermal tests using an inverse heat transfer technique. Transient temperature data from an experimental set up was collected and a simple, one-dimensional numerical model was constructed to replicate the temperatures within the test assembly. The Continuous Genetic Algorithm optimization technique in conjunction with a numerical thermal model and transient test data was used to estimate coefficients of a functional representation of the thermal property. The thermal properties, i.e., thermal conductivity and specific heat, of an alumina insulation felt were estimated over the temperature range of 300 K to 1700 K at various constant static pressures in nitrogen gas and compared with published data. The resulting thermal property estimates were within 10% of published values over the entire temperature range at various pressures. The methodology, application, and results are presented.

Frye, Elora↗