Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TOMOGRAPHY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Multi-scan computed tomography defect detectability

Systems and methods for representing internal defects of an object to determine defect detectability using a multi-scan computed tomography (CT) approach are disclosed. A defect-free object may be scanned using a CT machine. In one or more separate scans, phantom defects may be imaged and the resulting projections combined and reconstructed to represent internal defects. The air-normalized intensities of the object and the phantom defect may be used to represent voids and inclusions. Subtraction of materials may be represented by the quotient of the air-normalized intensities thereof, and the addition of materials may be represented by the product of the air-normalized intensities thereof. A void may be represented by subtracting a phantom defect scan from the object scan. An inclusion may be represented by creating a void, scanning an additional phantom defect, and adding the additional phantom defect in the volume created by the void.

Schiefelbein, Bryan E.↗

Few-view computed tomography reconstruction using deep neural network inference

A system for generating 2D slices of a 3D image of a target volume is provided. The system receives a target sinogram collected during a computed tomography scan of the target volume. The system inputs the target sinogram to a convolutional neural network (CNN) to generate predicted 2D slices of the 3D image. The CNN is trained using training 2D slices of training 3D images. The system initializes 2D slices to the predicted 2D slices. The system reconstructs 2D slices of the 3D image from the target sinogram and the initialized 2D slices.

Kim, Hyojin↗

Core Characterization: Computer Tomography, Geochemical, and Core Petrophysical Workflows for Emerging Critical Mineral Plays

The National Energy Technology Laboratory’s geoimaging lab in Morgantown, WV has been performing core characterization using multi-resolution Computed Tomography (CT) imaging and multisensor corelogger which allows for cm-resolution elemental and petrophysical measurements along whole core. This workflow has historically been used in unconventional gas plays and potential carbon storage locations. This rapid core characterization leads itself well as a first phase process in CM/REE evaluation efforts allowing for high-resolution, non-destructive investigation of elemental concentration using X-Ray Fluorescence and examination of core features through CT imaging.

Paronish, Thomas J.↗

Tomography of Atomic Nuclei

We carry out continuum quantum Monte Carlo calculations of the quantum-mechanical Wigner distribution functions of selected nuclei, up to $^{16}$O. These distributions provide a form of quantum tomography of the spatial and momentum structure of the system. They also help identify the location of high-momentum regions in atomic nuclei and provide insight into the onset of alpha clustering. Besides their intrinsic interest, these distributions will be useful for neutrino event generators, as they correlate the positions and momenta of nucleons in the initial target state. To facilitate their application, we address the need to store them compactly by developing an accurate Gaussian Process emulator that automatically preserves their normalization.

Rocco, Noemi [Valencia U., IFIC; Fermilab]↗

Seismic tomography of compressional wave velocity and attenuation structure for Makushin Volcano, Alaska

Located in the central portion of the Alaska-Aleutian subduction zone, Makushin Volcano is among the most active volcanoes in the United States and has been classified as a very high threat by the National Volcano Early Warning System based on its eruptive history and proximity to the City of Unalaska and international air routes. In 2015, five standalone seismic stations and three mini seismic arrays of 15 stations each were deployed on Unalaska Island to supplement the Alaska Volcano Observatory permanent seismic network. This temporary array was operational for one year. Taking advantage of the increased azimuthal coverage and the array's increased earthquake detection capability, we developed body-wave Vp and Vp/Vs seismic images of the velocity structure beneath the volcano. Our results show a complex structure with the upper 4 km of the crust. The shallow high-Vp features possibly delineate remnant magma pathways or conduits. Low-Vp regions are found east of the caldera at approximately 4–8 km depth. This is in agreement with previous seismic tomographic work and InSAR-based geodetic models, which had identified this region as a possible long-term source of magma. A three-dimensional compressional wave attenuation model complemented the velocity models. In general, we observe regions of corresponding low P-wave velocity and high attenuation east of the summit caldera between 5 and 7 km depth, supporting the presence of a melt-rich zone. The absolute Vp values (5.5–6.0 km/s) in this region are consistent with the presence of a magma body with a mafic signature. Here, we suggest that a triggering mechanism that involves mafic injections into a more evolved shallow magma chamber is representative of the current magmatic system below the volcano, similarly to what petrological studies have inferred for past eruptions.

58 GEOSCIENCES↗

Three-dimensional electron temperature measurement of inertial confinement fusion hotspots using x-ray emission tomography

Here we present a novel approach to reconstruct three-dimensional (3D) electron temperature distributions of inertially confined fusion plasma hotspots at the National Ignition Facility. Using very limited number of two-dimensional (2D) x-ray imaging lines of sight, we perform 3D reconstructions of x-ray emission distributions from different x-ray energy channels ranging from 20 to 30 keV. 2D time-integrated x-ray images are processed using the algebraic reconstruction technique to reconstruct a 3D hotspot x-ray emission distribution that is self-consistent with the input images. 3D electron temperatures are computed using the energy channel ratios. We demonstrate the high accuracy and applicability of this method with different complex hotspot geometries in both synthetic and experimental results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fast and noise-tolerant determination of the center of rotation in tomography

High-quality tomographic reconstruction is not possible without the accurate localization of the center of rotation. Poor localization leads to artifacts in the data and can even cause reconstructions to fail. There are many approaches to solving this problem, some of which involve the collection of full sinograms, or even provisional tomographic reconstructions, in order to determine the center of rotation. Here, a simple method based on the expected symmetry of the Fourier transform of summed projections approximately 180° apart is presented; unlike cross-correlation methods, it requires only a single Fourier transform to compute, and uses mainly low spatial frequency information which is less susceptible to noise. This approach is shown to be fast, and robust against poor signal-to-noise as well as to projection images acquired at angles that are not exactly 180° apart. This rapid method can be useful as a first step in the processing of tomographic data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

EGS Collab Experiment 1: 3D Seismic Velocity Model and Updated Microseismic Catalog Using Transfer-Learning Aided Double-Difference Tomography

This package contains a 3D Seismic velocity model and an updated microseismic catalog associated with a proceedings paper (Chai et al., 2020) published in the 45th Workshop on Geothermal Reservoir Engineering. The 3D_seismic_velocity_model text file contains x (m), y(m), z(m), P-wave velocity (km/s), P-wave velocity quality indicator (1 for well-constrained; 0 for poorly constrained), S-wave velocity (km/s), and S-wave velocity quality indicator (1 for well-constrained; 0 for poorly constrained). The Updated_MEQ_catalog text file contains event origin time, x(m), y(m), z(m), error in x (m), error in y (m), error in z (m), and RMS misfit (millisecond). The 3D_seismic_P-wave_velocity_model animation file shows slices of the 3D P-wave velocity model. The 3D_seismic_S-wave_velocity_model animation file shows slices of the 3D S-wave velocity model. The Interactive_MEQ_locations API file is an interactive visualization of the updated microseismic event locations. The visualization allows users to view the event locations by dragging, rotating, and zooming in. References: Chai, C., Maceira, M., Santos-Villalobos, H. J., Venkatakrishnan, S. V., Schoenball, M., and EGS Collab Team, 2020, Automatic Seismic Phase Picking Using Deep Learning for the EGS Collab Project, in PROCEEDINGS, 45th Workshop on Geothermal Reservoir Engineering, edited, Stanford University, Stanford, California, 45, 1266-1276.

15 GEOTHERMAL ENERGY↗

Description of a prototype emission-transmission computed tomography imaging system

We have developed a prototype imaging system that can perform simultaneous x-ray transmission CT and SPECT phantom studies. This system employs a 23-element high-purity-germanium detector array. The detector array is coupled to a collimator with septa angled toward the focal spot of an x-ray tube. During image acquisition, the x-ray fan beam and the detector array move synchronously along an arc pivoted at the x-ray source. Multiple projections are obtained by rotating the object, which is mounted at the center of rotation of the system. The detector array and electronics can count up to 10(6) cps/element with sufficient energy-resolution to discriminate between x-rays at 100-120 kVp and gamma rays from 99mTc. We have used this device to acquire x-ray CT and SPECT images of a three-dimensional Hoffman brain phantom. The emission and transmission images may be superimposed in order to localize the emission image on the transmission map.

NASA Discipline Musculoskeletal↗

Updates to the Regional Seismic Travel Time (RSTT) Model: 1. Tomography

Abstract A function of global monitoring of nuclear explosions is the development of Earth models for predicting seismic travel times for more accurate calculation of event locations. Most monitoring agencies rely on fast, distance-dependent one-dimensional (1D) Earth models to calculate seismic event locations quickly and in near real-time. RSTT (Regional Seismic Travel Time) is a seismic velocity model and computer software package that captures the major effects of three-dimensional crust and upper mantle structure on regional seismic travel times, while still allowing for fast prediction speed (milliseconds). We describe updates to the RSTT model using a refined data set of regional phases (i.e., Pn, Pg, Sn, Lg) using the Bayesloc relative relocation algorithm. The tomographic inversion shown here acts to refine the previous RSTT public model ( rstt201404um ) and displays significant features related to areas of global tectonic complexity as well as further reduction in arrival residual values. Validation of the updated RSTT model demonstrates significant reduction in median epicenter mislocation (15.3 km) using all regional phases compared to the iasp91 1D model (22.1 km) as well as to the current station correction approach used at the Comprehensive Nuclear-Test-Ban Treaty Organization International Data Centre (18.9 km).

58 GEOSCIENCES↗

Assessment of metadynamic recrystallization in single copper particle impacts by focused ion beam tomography

We study single Cu-on-Cu impacts relevant to cold spray deposition and quantitatively analyze the metadynamic recrystallization (mDRX) that takes place after the impact by virtue of lingering impact adiabatic heat. Unlike prior studies, the current full 3D tomographic analysis of the mDRX volume shows that mDRX is extremely common in such impacts, although it is often missed when examining 2D sections. We also report an unexpected trend: there is a “sour spot” for mDRX at velocities about 20–40 % above the velocity for particle adhesion. This non-monotonic trend is contrary to the expectations based on increasing adiabatic heating with velocity. With a schematic model, we show that the trend can be explained on the basis of heat transfer: cooling of the heat-affected region is limited by transport through the bonded regions at the particle-substrate interface. Thus, bonding has a prominent role in the heat dissipation process and the best bonded particles most rapidly bulk quench, avoiding mDRX. Here, the developed semi-empirical model aligns with the experimental findings and may help inform microstructural evolution during cold spray and post-spray processing.

FIB-SEM tomography↗

Understanding coarsening of a post-corrosion microstructure in a molten salt by combining phase-field modeling and in situ tomography

Alloys corroding in molten salt have been observed to form bicontinuous, nanoporous microstructures via dealloying, which subsequently undergo coarsening due to facile transport in high-temperature conditions. In this work, we describe a methodology to elucidate the underlying transport mechanisms during coarsening of a bicontinuous microstructure via quantitative comparisons between phase-field simulations and four-dimensional in situ experiments, in this case X-ray nanotomography of the coarsening of a dealloyed 80 wt% Ni-20 wt% Cr microwire in molten KCl-MgCl 2 at 800°C. We conduct phase-field simulations initialized from experimental data to model coarsening via three different transport mechanisms: surface diffusion, solid bulk diffusion, and liquid bulk diffusion. These simulations reproduce key features of the experiment, such as the densification of the outer layer of the dealloyed wire and the reduction in radius over time. We quantitatively compare different microstructural characteristics between the simulations and experiment and extract temporal scaling factors that optimally match the time scales of the simulations to that of the experiment. This allows us to evaluate morphological similarity between the simulations and experiment and relate the experimental coarsening kinetics to fundamental material properties. We find that surface diffusion is most likely to be the dominant coarsening mechanism, and its kinetics imply a surface diffusivity of D S = 8.9 x 10 -20 m 3 /s, which is within the range of reported values for Ni-vacuum interfaces at 800°C. However, the difference between the experiment and the surface diffusion simulation increases substantially at late times, suggesting that other mechanisms, such as the dissolution of residual Cr, may be at play.

36 MATERIALS SCIENCE↗

Quantitative microstructural investigation of 3D-printed and cast cement pastes using micro-computed tomography and image analysis

Highlights: • Processing alters the microstructure in 3D-printed lamellar cubic element. • A unique patterned and connected pore microstructure network exists. • Micro-channels are connected through micro-pores present at interfaces regions. • Three distinct pore volume domains exists in hardened microstructure. • Volume and frequency of pore, hydrated, and unhydrated clusters are dissimilar. Microstructural phases and mechanical properties of lamellar 3D-printed and cast hardened cement paste (hcp) elements were investigated using a lab-based X-ray microscope at two levels of magnification (0.4× and 4×). K-means clustering was used for quantitative image analysis. The entire volume of intact 3-days-old 3D-printed and cast hcp elements was characterized at 0.4× magnification. Three microstructural features (macro-pores, micro-channels, and interfacial micro-pores) were found to reside in three distinct pore size domains. The largest pores of the 3D-printed element were larger than the largest pores of the reference cast hcp element. Moreover, the smallest pore sizes of the 3D-printed element were found to be smaller than those present in the cast counterparts. Micro-channels were found to be connected to one another through the micro-pores present at interfacial regions, indicating the presence of a uniquely patterned and interconnected pore network. The role of locally weak and porous interfaces on mechanical response and fracture properties is discussed.

36 MATERIALS SCIENCE↗

Positron Emission Tomography Imaging of Functional Transforming Growth Factor β (TGFβ) Activity and Benefit of TGFβ Inhibition in Irradiated Intracranial Tumors

Transforming growth factor β (TGFβ) promotes cell survival by endorsing DNA damage repair and mediates an immunosuppressive tumor microenvironment. Thus, TGFβ activation in response to radiation therapy is potentially targetable because it opposes therapeutic control. Strategies to assess this potential in the clinic are needed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗