Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TANKS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Water Contamination Impacts on Biodiesel Antioxidants and Storage Stability

Biodiesel (fatty acid methyl esters) can oxidize in storage to form acids and gums that negatively impact engine performance and durability. Antioxidant additives are used to increase biodiesel storage stability, and previous studies that evaluated the effectiveness of antioxidants demonstrated that more polar antioxidants tend to be the most effective (provide the largest improvement in stability per unit of antioxidant added). However, polar antioxidants have significant water solubility, and diesel fuel storage tanks are commonly contaminated with water (forming a layer of water under the fuel). This study investigates whether nonpolar antioxidants, which are less effective in dry environments, might be more effective under wet conditions simulating real-world storage. Biodiesel blends treated with polar and nonpolar antioxidants were subjected to accelerated aging using the ASTM D4625 protocol (storage at 43 °C, open to air, for up to 24 weeks) both with and without added water. Fuels treated with polar/higher-effectiveness compounds and stored in contact with water (simulating water in a storage tank) or high humidity showed accelerated loss of stability compared to dry storage. The same fuel treated with a nonpolar antioxidant and stored in the same conditions did not exhibit accelerated stability loss and thus had higher storage stability over the long term despite treatment with an initially less effective additive. Analysis of the fuels during aging showed that this loss of stability was not due to oxidation but rather extraction of the polar antioxidant into the water layer. Antioxidant additives that are incompatible with wet or humid storage conditions were found to cause faster-than-anticipated loss of stability, which was preventable with use of nonpolar additives.

09 BIOMASS FUELS↗

Quantification of Raman-Interfering Polyoxoanions for Process Analysis: Comparison of Different Chemometric Models and a Demonstration on Real Hanford Waste

The Hanford site represents a complicated environmental remediation challenge, remaining from the production of nuclear weapons. Over 100 million gallons of liquid radioactive waste of unknown composition will be chemically processed and vitrified, but the varying chemical composition and highly radioactive nature of the waste preclude the implementation of more developed, offline technologies to determine the composition. The only practical approach to waste treatment will require the significant utilization of real-time, chemometric modeling approaches. Although chemometric approaches have been applied to the analysis of Hanford waste, the models developed were highly tank-specialized, and limited discussion was provided on how models fared with interfering signals. As the tank waste is largely composed of oxoanions, which tend to have interfering Raman spectra, the general question was posed as to what chemometric approach is best suited to accurately quantify analytes in the presence of interfering signals. This was carried out by examining the ability of classical least square (CLS), principal component regression (PCR), partial least square (PLS), and locally weighted regression (LWR) to quantify NO 3 – and CO 3 2– using their bands around 1050 cm –1 . Finally, for all samples, the PLS-based model was found to be the most efficient approach from a model building and application perspective.

54 ENVIRONMENTAL SCIENCES↗

Metal Organic Frameworks for Xenon Storage Applications

The demand for cheap and convenient xenon storage continues to rise due to its wide spectrum of applications. It is expected that solid-state adsorbents can provide significant advantages over the current isolated stainless-steel tank-based storage technologies. In this context, we investigated metal organic frameworks for use as adsorbents for xenon. Initially, three representative MOFs were synthesized and characterized in terms of Xe storage. The results were used to validate a computational modeling approach, which was later extended to a larger set of materials. The collected results allowed us to rationalize the key parameters (pore volume, surface area, void fraction etc.), which are important for good performance and selection of the best materials for xenon storage

Noble gas, Storage, MOFs↗

99 TcO 4 - removal from legacy defense nuclear waste by an alkaline-stable 2D cationic metal organic framework

Removal of 99 TcO 4 - from legacy defense nuclear tank waste at Savannah River Site is highly desirable for the purpose of nuclear safety and environmental protection, but currently not achievable given the extreme conditions including high alkalinity, high ionic strength, and strong radiation field. Herein, we present a potential solution to this long-term issue by developing a two-dimensional cationic metal organic framework SCU-103, showing ultrahigh stability in alkaline aqueous media and great resistance to both β and γ radiation. More importantly, it is very effective for 99 TcO 4 - separation from aqueous media as demonstrated by fast exchange kinetics, high sorption capacity, and superior selectivity, leading to the successful removal of 99 TcO 4 - from actual Savannah River Site high level tank waste for the first time, to the best of our knowledge. In addition, the uptake mechanism is comprehensively elucidated by molecular dynamics simulation and density functional theory calculation, showing a unique chemical recognition of anions with low charge density.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Hydrogen Mitigation Process Testing at Nevada Solar One

The National Renewable Energy Laboratory (NREL) and Acciona Solar Power (ASP) developed and installed a process that addresses the issue of hydrogen buildup in Acciona's Nevada Solar One power plant. Our method selectively removes hydrogen from the expansion tanks of the power plant to control hydrogen levels in the circulating heat-transfer fluid (HTF). During previous work, we developed a sensor that measures hydrogen partial pressure in the expansion-tank headspace gas. We demonstrated that our sensor measures hydrogen levels over a wide range of partial pressure from 10 mbar down to 0.003 mbar. More recently, we conceived and developed an integrated process module that performs both hydrogen sensing and separating functions. The sensor/separator measures hydrogen partial pressure in the headspace gas in the same way as our original sensor design. Additionally, the integrated module separates hydrogen from the headspace gas to reduce hydrogen to the level needed to maintain the performance of receivers in the collector field. Laboratory testing at NREL showed that the sensor function had an accuracy of +/-7%, and the hydrogen extraction rate for separator function was consistent with our modeling predictions. The primary benefit of this module is its simple design, both in terms of function and incorporation into the HTF subsystem of the power plant. Most recently, NREL and ASP completed installation and initial testing of a mitigation process at ASP's Nevada Solar One power plant in Boulder City, Nevada. In this paper, we report on the completed installation, initial testing, and plans to bring the process to full automation, so that it can be operated unattended on a daily schedule.

chemical elements↗

Geometric Optimization of an Electrochemical Purification Cell to Prevent Corrosion in CSP Plants During Operation

When exposed to moisture or oxygen, molten chloride salts produce corrosive impurities which degrade containment alloys. This can significantly decrease the lifetime and increase costs of molten-salt-based systems. To overcome this barrier, we designed and modeled an electrochemical purification cell to remove the corrosive impurity MgOH+. Various reactor architectures, including continuous stirred tank reactors (CSTRs) and plug flow reactors (PFRs) were investigated. Steady-state thermoelectric properties were evaluated using analytical methods, allowing assessment of the effects of structure and design parameters such as flow rate, cell length, and cross-sectional area of molten salt. The results suggest that our design could most effectively increase reliability and decrease costs of molten-chloride-salt-based systems by protecting them during continuous operation using an annular plug flow reactor.

analytical modeling↗

SAM Two-Phase Flow Model Development and Applications for Operational Transients in Advanced Reactors

As advanced nuclear technologies continue to develop, the need for the flexible operation and generation of these advanced reactors becomes necessary to maximize economic potential. As large-scale experiments are not always feasible, modeling and simulations of advanced reactors play a crucial role in design optimization and analysis. The SAM (System Analysis Module) code developed at Argonne National Laboratory is a state-of-the-art system-level thermal-hydraulic code aimed at simulating advanced reactor systems. Recent code developments have implemented two-phase flow modeling using the homogeneous equilibrium model, and a new steam generator component has been developed to utilize the two-phase flow implementation. In addition to verification tests, a load-following simulation was performed to model a realistic load-following transient in a proposed integrated system consisting of a conceptual advanced reactor known as the Advanced Burner Test Reactor (ABTR) and thermal energy storage (TES) tanks. The integrated system model uses two large TES tanks designed for sodium and a model helical coil steam generator to simulate the operational load-following transient. The flow rates of the feedwater and secondary loops are regulated to meet a prescribed steam generator load consistent with the electricity demand over a 24-h period. In conclusion, the results found the ABTR system was able to maintain stable reactor conditions and primary- and secondary-side characteristics over the course of the load-following transient.

Advanced Burner Test Reactor (ABTR)↗

Small to Full-Height Scale Comparisons of Cesium Ion Exchange Performance with Crystalline Silicotitanate

Crystalline silicotitanate (CST) ion exchanger is planned to be used to remove cesium (137Cs) from the aqueous phases of Hanford tank wastes in preparation for vitrification at the Waste Treatment and Immobilization Plant (WTP) Pretreatment Facility. Column scale up testing was conducted to evaluate performance of Cs exchange onto the CST. Batch contact testing was conducted to assess exchange kinetics of Cs exchange at four different CST PSDs. Column testing was conducted at three column sizes, small (2.5% full height), medium (12% full height), and full height, to assess Cs load performance behavior. Testing at the small scale was compared to actual Hanford tank waste testing to verify the validity of simulant tests to accurately represent full height column performance. A change in CST particle size was essential in scaling the small column dynamics up to full scale. Based on these results, a determination of intraparticle and film diffusion impacts on overall mass transfer coefficients will allow future modeling of the breakthrough performance at a range of process conditions.

Westesen, Amy M.↗

Open-source simulation platform for air source heat pump integrated with thermal energy storage

Here, this article introduces a modular simulation platform for assessing thermal energy storage (TES) integrated with air source heat pumps (ASHP). The Python platform is an open-source library that includes classes for modeling air-air and air-water heat pumps, TES devices, and the heating load of residential buildings. To validate the ASHP model, the study utilized experimental data obtained from a commercial heat pump evaluated at the National Renewable Energy Laboratory (NREL). The results indicate a mean deviation of 0.7% for COP across the operating range, with a maximum relative deviation of 12.6%. In terms of system heating capacity, the model had an average deviation of 4.3% compared to experimental results, with a maximum deviation of 8.2%. Three classes were implemented for modeling distinct types of TES devices: a generic TES based on energy balances, a sensible isothermal water tank, and a stratified water tank. Details of the mathematical models are provided, along with their respective strengths and limitations. An example is provided showcasing the integration of a residential 10 kWh thermal storage unit with an ASHP operating in Denver, CO. The comparison of two different discharge criteria for the TES unit highlights the importance of control strategies in the system performance.

25 ENERGY STORAGE↗

Thermal Analysis of a Superconducting Undulator Cryostat for the APS Upgrade

The Advanced Photon Source Upgrade includes four 4.8-m-long superconducting undulator (SCU) cryostats, each containing two planar undulator NbTi magnets up to 1.9 m long. The cooling is provided by six cryocoolers arranged in three thermal circuits. The magnets are indirectly cooled with LHe penetrating through channels in the magnet cores. This 4 K circuit, which also includes a LHe tank, is cooled by five 4 K cryocooler 2nd stages. A beam vacuum, which is thermally isolated from the magnets, is cooled by one 10 K cryocooler 2nd stage. A thermal shield and warm parts of current leads are cooled by the 1st stages of all six cryocoolers. This paper presents an ANSYS-based thermal analysis of the new SCU cryostat including all thermal circuits. The benchmarked thermal conductance between the cryocooler cold heads and the LHe tank are used in the calculations as well as the measured cryocooler load lines. The model predicts temperatures in the system, total 4 K heat loads, and excess cooling power for various operational modes of the undulator.

Shiroyanagi, Y.↗

Capacitor Design for Self-Resonant Coils for Long-Distance Wireless Power Transfer System

In this paper, an integrated capacitor design is proposed for higher-order resonant tank topologies for self-resonant coils, such as series, parallel, LCC, LLC, etc. The capacitor is one of the large, lossy, and thermally vulnerable components of a high-frequency resonant tank, and designing a high-voltage, thermally stable resonant capacitor can be highly challenging. Designing the extremely high-voltage capacitor as an integral part of the coil reduces the size and complexity of the coil assembly. This paper proposes a low-loss PCB-based high-voltage capacitor design to achieve that target, which can be implemented as an integral part of the coil. The proposed capacitor designs are simulated using Multiphysics FEA and tested experimentally. A 23 kV, 133 pF capacitor prototype was built and tested as part of a 1 kW long-distance wireless charging system. The test results verify the capacitor’s voltage, current, and thermal resiliency performance.

Mohammad, Mostak [ORNL] (ORCID:0000000256388783)↗

System Resilience Benefits of Dual-Fuel Capable Generators

The growing dependency on natural gas (NG) for power generation raises challenges for ensuring the resilience of power systems during extreme cold weather. Dual-fuel capable generators that can switch from burning NG to distillate fuel oil during a NG shortage offer one way to alleviate these challenges. In this study, the impacts of gas unavailability on the IEEE 73- bus reliability test system (RTS) with 2019 updated generation mixture are explored. An extension to the standard production cost model formulation of unit commitment and economic dis- patch is proposed to allow representation of dual-fuel capable generators that can switch fuels between NG and distillate oil with a specified oil tank capacity and tank refueling capability. The operation of the system under gas unavailability with 0%, 25%, 50%, 75%, and 100% of combined cycle and combustion turbine generators as dual-fuel capable with a one-day supply of fuel oil are simulated using PLEXOS, a production cost model. The dual-fuel generator performance, unserved energy, and system costs are fully assessed.

duel-fuel generator performance↗

Experimental Study of Thermal Management and Enhancement of Adsorption-Based Onboard Hydrogen Storage System

Abstract Although hydrogen has one of the highest specific energies, its energy density in terms of volume is very poor compared to liquid fuels. Thus, to achieve attractive energy density for hydrogen, either high-pressure compression or a storage method is needed. For onboard (vehicles) hydrogen storage, up to 700 bars are needed for commercial fuel cell vehicles. This creates extreme requirements for material strength and thus safety concerns. A new metal-organic framework 5 (MOF-5) was selected as the adsorbent for H2 storage, as it provides promising storage capacity and is commercially available. Under the same H2 storage capacity and tank volume, the adsorption system is expected several folds reduction in pressure. Under the current study, a unique thermal management design using Modular Adsorbing Tank Insert (MATI) is paired with conduction-enhanced compressed MOF-5 beds. Compared to bare beds without conduction enhancement, all beds with conduction enhancement using either aluminum pins or expanded natural graphite (ENG) have shown various levels of improvement on bed thermal response, which can potentially help expedite system charge and discharge cycle times for real applications.

Electrochemistry↗

Techno-Economic Analysis of Green Hydrogen Energy Storage in a Cryogenic Flux Capacitor

Abstract The Cryogenic Flux Capacitor (CFC) is a cold, dense energy storage core that is being studied in the cryo-compressed, about 300 bar and 80K, region of gaseous hydrogen (GH2) storage and liquid hydrogen (LH2) region near the normal boiling point. Hydrogen storage is improved by physically bonding the molecules within the nanoscale pores of the aerogel composite blanket material. The process of bonding or debonding is governed by principles of physical adsorption (physisorption) and thermodynamics. The large surface area afforded by the nanoporous aerogel (∼1,000 m2/g) allows its storage performance to easily exceed capacities of high-pressure GH2 storage for an equivalent volume. With the integrated aerogel, subscale tests have shown that storage is increased by about 36% over a simple tank filled with GH2 at the same operating temperature and pressure. For LH2 conditions, the CFC is shown to operate at improved densities, but testing is ongoing. For the techno-economic analysis (TEA), the source of hydrogen is compared between onsite steam methane reforming (SMR) and onsite solar photovoltaic (PV) panels providing power to electrolyzers to produce green GH2. The TEA compares pure hydrogen produced at a small scale for a 25 MW power system and at a large scale in a 500 MW power system. The system allowed for hydrogen imports and exports at a set price with a tank sized for 10 hours of power production. The two power producing technologies are a combined cycle gas turbine (CCGT) and hydrogen fuel cells. The SMR system uses natural gas as an input and includes a carbon capture and storage (CCS) system. The levelized cost of electricity (LCOE), levelized cost of hydrogen (LCOH), and levelized cost of storage (LCOS) are developed based on the capital cost and operating cost of the systems. The results are shown for current costs using a 2021 benchmark and DOE projections for cost improvements by 2030. The TEA showed that onsite hydrogen generation from SMR has an LCOH of about 1.4 to 2 USD per kg over the life of the plant and the PV hydrogen production LCOH is about 5.2 to 5.5 USD per kg. The LCOS of conventional GH2 systems is estimated to be $210/MWh and cost of storage for LH2 systems is $205/MWh for fuel cell systems and $249/MWh for CCGT systems. CFC improved the LCOS of all these systems to $198/MWh, $191/MWh and $233/MWh respectively. The LCOE also improved with conventional systems between $171/MWh and $228/MWh improved by CFC to between $167/MWh and $212/MWh. Using projections for improvement in costs following DOE’s goals by 2030, green hydrogen improved to as low as $78/MWh LCOS and LCOE for conventional cases. CFC improved over conventional storage with the lowest LCOS being $62/MWh and the lowest LCOE being $73/MWh. These results correspond to an LCOH of $2/kg. Finally, the TEA shows how LCOE is improved for hydrogen conditioning and storage over conventional systems and caverns in the 10 to 50 hour range.

08 HYDROGEN↗

Critical Shear Stress for Erosion Under Laminar Jet Flow

Particle erosion is an important process in both natural and manmade environments. For example, in natural environments particle or sediment erosion rates determine the course of rivers, depth of streams, and fate of deltas. The interplay between erosion rates and flow patterns can have dramatic impact on shorelines. Where hydrodynamic jet flows or rip currents change direction, sediments may accumulate or disperse altering the shape of coastlines and the ecosystems and economies that rely on them. In man-made systems, jet flows may be used to mobilize particles from surfaces or within industrial scale mixing tanks. For example, in the nuclear industry, impinging jet mixers may be used to mobilize and suspend sludges at the bottom of waste tanks. In each of these examples, the Shields diagram is useful to determine the conditions under which erosion occurs. This diagram plots the scaled critical shear stress for erosion as a function of the particle size as embedded in particle Reynolds numbers, Archimedes numbers, or their equivalents. Although the data, that carries a large spread, is largely in agreement with mathematical models, for the smallest particles, model predictions diverge from each other and from experimental data. Indeed, there is substantial uncertainty about the Shields diagrams at relatively small particle sizes and flow rates. Here we evaluate critical shear stresses for erosion under laminar jet flow. To date critical shear stresses for erosion, as embodied in Shields diagrams, have largely been developed for turbulent flow both experimental and mathematically. However, curves on the Shields diagrams diverge among various models at lower particle Reynolds numbers. Indeed, how critical shear stresses for erosion develop under fully laminar jet flow conditions (not simply laminar boundary layers under turbulent flow) remains unclear. Here we address this gap, which is particularly important for mobilization of the smallest particles. We find the Shields parameter to be inversely proportional to the particle Reynolds numbers under laminar jet flow conditions similar to turbulent conditions.

critical shear stresses, erosion rates, effective ↗

Community Resilience through Low-Temperature Geothermal Reservoir Thermal Energy Storage

Submitted data include simulations related to underground thermal battery (UTB) simulations described in Modeling and efficiency study of large scale underground thermal battery deployment, presented at GRC, October 2021. The UTB is comprised of a tank of water, a helical heat exchanger in the center of tank and connected to a water source heat pump, and a phase change material (PCM). Compared to a conventional VBGHE, the UTB is designed to be installed at a much shallower depth, therefore, with a cheaper cost. In addition, the GSHP efficiency is improved due to natural convection of water and additional load capacity provided by PCM. The goal of this study is to explore factors that may affect the efficiency of large-scale UTB deployment. The simulations found in this submission relate to the report on UTB deployment.

15 GEOTHERMAL ENERGY↗

Physical Modeling of Coupled Thermohydraulic Behavior of Compacted MX80 Bentonite during Heating

Abstract This paper describes a tank-scale test setup and experimental methodology used to investigate coupled heat transfer and water flow processes during heating of compacted MX80 bentonite to high temperatures. Specifically, a temperature of 200°C was maintained by a cylindrical heating element at the center of a compacted bentonite layer containing an array of temperature, dielectric, and relative humidity sensors. In addition to providing an evaluation of the spatiotemporal variations in temperature, relative humidity, degree of saturation, and global volume, the coupled thermohydraulic properties of the bentonite were assessed. A wetting front was initially observed to move away from the central heater, followed by a drying process until reaching thermohydraulic equilibrium. The soil–water retention curve (SWRC) of the bentonite followed a wetting scanning path before following the primary drying path exhibiting a shift in water retention with elevated temperature. Results from the tank-scale test can be used for validation of numerical simulations of drying processes in the engineered barrier system of a high-level radioactive waste geological disposal repository and confirm that a temperature-dependent hysteretic SWRC with scanning paths is required to accurately capture the bentonite response.

Engineering↗

MASK4 Test Campaign for Sandia WaveBot Device

This data and report details the findings from a wave tank test focused on production of useful work of a wave energy converter (WEC) device. The experimental system and test were specifically designed to validate models for power transmission throughout the WEC system. Additionally, the validity of co-design informed changes to the power take-off (PTO) were assessed and shown to provide the expected improvements in system performance. These data describe the "MASK4" wave tank test of the Sandia WaveBot device. The WaveBot device has been tested a number of times in different permutations at the US Navy's Maneuvering and Sea Keeping (MASK) basin. Each test in this series is referred to as MASK1, MASK2, etc. The WaveBot device was first tested in one degree of freedom (heave) in 2016. This MASK1 test focused primarily on system identification and modeling. After MASK1, major modifications were performed to improve the overall real-time control and measurement system, improve the heave drive train, and add surge and pitch degrees of freedom. The second set of testing, which was broken up in to two stages: MASK2A and MASK2B, focused on bench testing and closed-loop control performance as well as nonlinear modeling. MASK3 then focused on multi-input, multi-output modeling and control for maximization of electrical power. The attached report presents the results from MASK4, which focuses on detailed modeling of the power conversion chain and validation co-design principles by way of the introduction of a magnetic spring. The test log, report, and data from the MASK4 test of the WaveBot augmented with a tunable magnetic spring. Processing codes can be found at the Github link below.

16 TIDAL AND WAVE POWER↗