Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TANK”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Characterizing Droplet Formation from Non-Linear Slosh in a Propellant Tank

The Fluid Dynamics Branch (ER42) at the Marshall Space Flight Center (MSFC) was tasked with characterizing the formation and evolution of liquid droplets resulting from nonlinear propellant slosh in a storage tank. Lateral excitation of propellant tanks can produce high amplitude nonlinear slosh waves through large amplitude excitations and or excitation frequencies near a resonance frequency of the tank. The high amplitude slosh waves become breaking waves upon attaining a certain amplitude or encountering a contracting geometry such as the upper dome section of a spherical tank. Inherent perturbations in the thinning regions of breaking waves result in alternating regions of high and low pressure within the fluid. Droplets form once the force from the local pressure differential becomes larger than the force maintaining the fluid interface shape due to surface tension. Droplets released from breaking waves in a pressurized tank may lead to ullage collapse given the appropriate conditions due to the increased liquid surface area and thus heat transfer between the fluids. The goal of this project is to create an engineering model that describes droplet formation as a function of propellant slosh for use in the evaluation of ullage collapse during a sloshing event. The Volume of Fluid (VOF) model in the production level Computational Fluid Dynamics (CFD) code Loci-Stream was used to predict droplet formation from breaking waves with realistic surface tension characteristics. Various excitation frequencies and amplitudes were investigated at multiple fill levels for a single storage tank to create the engineering model of droplet formation from lateral propellant slosh.

Brodnick, Jacob↗

Investigation of Damping Physics and CFD Tool Validation for Simulation of Baffled Tanks at Variable Slosh Amplitude

To meet the flight control damping requirement, baffles of various configurations have been devised to increase the natural viscous damping and decrease the magnitude of the slosh forces and torques. In the design of slosh baffles, the most widely used damping equation is the one derived by Miles, which is based on the experiments of Keulegan and Carpenter. This equation has been used in predicting damping of the baffled tanks in different diameters ranging from 12 to 112 inches. The analytical expression of Miles equation is easy to use, especially in the design of complex baffle system. Previous investigations revealed that some experiments had shown good agreements with the prediction method of Miles, whereas other experiments have shown significant deviations. For example, damping from Miles equation differs from experimental measurements by as much as 100 percent over a range of tank diameters from 12 to 112 inches, oscillation amplitudes from 0.1 to 1.5 baffle widths, and baffle depths of 0.3 to 0.5 tank radius. Previously, much of this difference has been attributed to experimental scatter. A systematical study is needed to understand the damping physics of baffled tanks, to identify the difference between Miles equation and experimental measurement, and to develop new semi-empirical relations to better represent the real damping physics. The approach of this study is to use CFD technology to shed light on the damping mechanisms of a baffled tank. First, a 1-D Navier-Stokes equation representing different length scales and time scales in the baffle damping physics is developed and analyzed. A well validated CFD solver, developed at NASA MSFC, Loci-STREAM-VOF, is applied to study vorticity field around the baffle and around the fluid interface to highlight the dissipation mechanisms at different slosh amplitudes. Previous measurement data are then used to validate the CFD damping results. The study found several critical parameters controlling fluid damping from a baffle: local slosh amplitude to baffle thickness (A/t), surface liquid depth to tank radius (h/R), local slosh amplitude to baffle width (A/W); and non-dimensional slosh frequency. The simulation highlights three significant damping regimes where different mechanisms dominate. The study proves that the previously found discrepancies between Miles equation and experimental measurement are not due to the measurement scatter, but rather due to different damping mechanisms at various slosh amplitudes. The limitations on the use of Miles equation are discussed based on the flow regime.

Yang, H. Q.↗

Two-Pendulum Model of Propellant Slosh in Europa Clipper PMD Tank

The objective of this fluids analysis is to model propellant slosh for the Europa Clipper mission using a two-pendulum model, such that controls engineers can predict slosh behavior during the mission. Propellant slosh causes shifts in center of mass and exerts forces and torques on the spacecraft which, if not adequately controlled, can lead to mission failure. The two-pendulum model provides a computationally simple model that can be used to predict slosh for the Europa Clipper tank geometry. The Europa Clipper tank is cylindrical with a domed top and bottom and includes a propellant management device (PMD). Due to the lack of experimental data in low gravity environments, computational fluid dynamics (CFD) simulation results were used as 'real' slosh behavior for two propellants at three fill fractions. Key pendulum parameters were derived that allow the pendulum model's center of mass, forces, and moments to closely match the CFD data. The parameter trends were examined as a function of tank fill fraction and compared with solutions to analytic equations that describe the frequency of slosh in tanks with simple geometries. The trends were monotonic as expected, and parameters resembled analytical predictions; any differences could be explained by the specific differences in the geometry of the tank. This paper summarizes the new method developed at Goddard Space Flight Center (GSFC) for deriving pendulum parameters for two-pendulum equivalent sloshing models. It presents the results of this method and discusses the validity of the results. This analysis is at a completed stage and will be applied in the immediate future to the evolving tank geometry as Europa Clipper moves past its preliminary design review (PDR) phase.

Propellant Slosh↗

Liquefaction Study of Gaseous Oxygen Inside Mars Ascent Vehicle Propellant Tank

The in-situ production of propellants for Mars missions will utilize carbon dioxide (CO2) in the Mars atmosphere to produce oxygen. The oxygen then needs to be cooled, liquefied, and stored to be available for Mars ascent propulsion, which could be up to 2 years after liquefaction starts. Recent investigations have demonstrated the feasibility of both achieving zero boiloff and controlling the pressure of oxygen within a tank using high-efficiency reverse turbo-Brayton-cycle cryocoolers. A tube-on-tank configuration is being studied in this work. The cooling fluid circulating in the cryocooler system is routed through a network of cooling tubes on the oxygen tank. The oxygen gas produced from the in-situ production process is introduced into the chilled tank. A series of analysis of this configuration has been performed to investigate the liquefaction rate inside the tank, the thermal gradient near the top of the tank where the oxygen gas feeding tubing is located. The analyses include 2D axisymmetric CFD analysis using ANSYS Fluent, 1D thermal analysis using Matlab, and 3D thermal analysis using MSC Patran/pthermal. These three models correlate and validate each other.

Liquefaction↗

Experimental and CFD Investigation of the Titled Jet Behavior in the Zero Boil-Off Tank (ZBOT) Experiment

Screens are used in cryogenic storage tanks to diffuse the incoming gas or liquid injection/flow into the tank. Meshed screens were also used in the jet mixing pressure control tests of the Zero Boil-Off Tank (ZBOT) Experiment which was recently performed aboard the International Space Station (ISS). The ZBOT pressure control studies used a liquid jet that was intended to be aligned with the longitudinal axis of the tank. A cartridge consisting of a honeycomb flow straightener and two screen diffusers, one upstream of the honeycomb, and one downstream, were designed to obtain the desired velocity profile in a manner that would be consistent in all the tests and could also be used as an input to the CFD simulations. Unfortunately, during the flight operations, the Digital Particle Image Velocimetry (DPIV) measurements indicated that the jet actually exited the nozzle at an angle to the main axis. This unexpected tilt affected the motion and deformation of the ullage during the pressure control tests, influencing the initial pressure drops. Upon disassembling the experiment hardware, it was discovered that the screen diffuser upstream of the honeycomb was clogged with debris. Since this behavior is important, not only to the follow-on ZBOT-NC experiment, but also to the operation of cryogenics storage tanks in general, a series of ground-based experiments and parametric CFD model simulations were performed to understand and characterize the tilted flow in terms of the clogged area of the upstream screen and the jet velocity. The experimental and CFD results surprisingly and non-intuitively showed that although the modification of the flow originated from the clogging of the upstream screen, the presence of the downstream unclogged screen was also necessary to produce the tilted jet. Two different CFD models were used for the numerical simulations, and only the one using a porous media formulation to capture the screen pressure drop was able to produce the correct tilting behavior. Parametric runs with the porous media CFD model were used to characterize the jet tilt in terms of the blockage area and jet velocity for both the future ZBOT-NC Experiment and other propellant tank applications. Supported by NASA Biological & Physical Sciences (BPS) Division, Physical Sciences Research Program, NASA HQ, USA.

Cryogenic Fluid Management↗

Cryogenic Propellant Tank Drain Simulation with a Stratified Ullage Nodal Model

Cryogenic propellant tank pressurization systems maintain tank pressure within specified limits to comply with propellant thermodynamic and tank structural design requirements. Many pump-fed cryogenic liquid propulsion systems control tank pressure using an autogenous pressurization system. Autogenous pressurization systems vaporize and heat propellant to produce the pressurant gas delivered to the tank. While autogenous pressurization systems eliminate the need for a separate pressurant gas storage and delivery system, they couple pressurant mass requirements to propellant mass requirements. Accurate prediction of autogenous pressurant mass during propellant drain is essential in optimizing cryogenic propellant tank designs.

Richard G Hibbs↗

CFD Modeling of Bi-Directional PMD inside Cryogenic Propellant Tanks Onboard Parabolic Flights

Future cryogenic propulsion systems will require efficient methods with which to transfer cryogenic propellants from a depot storage tank to a customer receiver tank to minimize cost and maximize reusability. The Reduced Gravity Cryogenic Transfer project is currently developing advanced cryogenic fluid management technology and developing and validating new numerical models for three phases of transfer: line chilldown, tank chilldown, and tank fill. Additionally, multiple liquid nitrogen (LN 2 ) parabolic flight transfer rigs are being designed by universities and NASA to investigate the gravitational sensitivities that exist in these three technologies. In order to maximize the collection of low-g data during flights, it is required to extract as much (LN 2 as possible from the supply tank, despite variable gravity levels. The purpose of this paper is to present computational fluid dynamics (CFD) volume of fluid simulations of (LN 2 behavior in the supply tank onboard parabolic flights to validate the optimal design of a bi-directional propellant management device (PMD) using the commercial software FLOW-3D. A parametric study is conducted on the effects of gravity level, fill level, pore size, open area, thickness, and type of baffle on PMD performance. Based on results, the PMD as designed exceeds the targeted expulsion efficiency.

Jason Hartwig↗

Thermal Insulation for a High Temperature Molten Salt Storage Tank in a CSP Plant: Preprint

A ternary molten chloride has been suggested as a high temperature (550-720 °C) sensible heat storage medium for a two-tank system. An effective thermal insulation is proposed to provide an opportunity for the fabrication of both the hot and cold storage tanks from lower cost metals, e.g. A240-347H, by maintaining the tank wall below 500 °C. To achieve this, the hot storage tank mainly comprises of inner shell (11.4 cm of a refractory brick as liner (KX-99 ®), 30 cm of insulation brick) and outer metal shell, where 5 cm of frozen layer of PCM800 (NaCl), and 5 cm of ceramic wool fill the annular space between the shells. Another layer of ceramic wool was introduced at the outer side of the metal shell to keep the temperature lower than 60 °C. ANSYS Fluent was used for the numerical study of the cool down behavior of the system during idle period when tank is quarter-filled. The heat transfer modes were considered as radiation and natural convection heat transfer from the hot molten salt at 720 °C, conduction through the solid layers and convection heat transfer from the outer shell to the environment at 15 °C. The results showed that the proposed insulation system including a frozen layer of PCM800 maintains the temperature at the metal wall lower than 500 °C, and lower than 60 °C at the outer side of the tank. Apart from the insulation property of the frozen layer of PCM800, it absorbs any leak of hot molten salt, acting as a barrier between salt and the metal shell. The thermal performance analysis provide an insight into the benefits of the multilayer insulation.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Comparison of plug flow and multi-node stratified tank modeling approaches regarding computational efficiency and accuracy

Residential water heaters contain water stratified by temperature-driven density differences. This implies that a water tank can reach a state in which the top and bottom sections have different temperatures, unless mixing happens. A high degree of thermal stratification can improve the efficiency of some water heaters, by saving the amount of energy required for the heat-up process. Studies of stratification became popular in the 1970s and it remains an active research topic today. The research has led to the development of different models and techniques to better predict and define a stratified tanks behavior. By comparing these models and techniques used previously to describe thermal stratification, the phenomenon could be better understood, exploited, and used to increase efficiency and thermal energy capacity in modern water tanks. From the existing models, we found the one-dimensional standard plug-flow and a multi node model to be appropriate for analyzing the processes of the heat up and cool-down in a water tank. These two models are based on energy balances. This work involved comparing the accuracy and computational effort needed to implement these models. To assess accuracy, we compared both types of existing models to experimental data (also collected in this work) which included a heat up process using an external heat pump. This external process included a layering process that has an eddy diffusivity at five times the rate of thermal diffusion. For this project, we implemented the models in MATLAB, the multi-paradigm numerical computing environment. We quantified model accuracy using the root mean squared error between modeled data and experimental data for six measured tank temperatures. Comparing the accuracy and the computational time taken to run the simulation provides a method to contrast the performance of each model and a way to rate it. The multi node model was run using from 6 to 96 spatial nodes; the plug flow model was run using 1 to 0.001 º C temperature bin sizes. Additionally, timesteps were varied from 4 to 236 s. The results quantify the tradeoff between accuracy and computational time, providing guidance for simulations to intelligently select the best model type and simulation parameters. This research can be used to validate the pre-existing models and possibly improve the modern water tank.

Bulnes, Fernando Karg↗

Development of a Thermodynamic Model for the Hanford Tank Waste Operations Simulator - 12193

The Hanford Tank Waste Operations Simulator (HTWOS) is the current tool used by the Hanford Tank Operations Contractor for system planning and assessment of different operational strategies. Activities such as waste retrievals in the Hanford tank farms and washing and leaching of waste in the Waste Treatment and Immobilization Plant (WTP) are currently modeled in HTWOS. To predict phase compositions during these activities, HTWOS currently uses simple wash and leach factors that were developed many years ago. To improve these predictions, a rigorous thermodynamic framework has been developed based on the multi-component Pitzer ion interaction model for use with several important chemical species in Hanford tank waste. These chemical species are those with the greatest impact on high-level waste glass production in the WTP and whose solubility depends on the processing conditions. Starting with Pitzer parameter coefficients and species chemical potential coefficients collated from open literature sources, reconciliation with published experimental data led to a self-consistent set of coefficients known as the HTWOS Pitzer database. Using Gibbs energy minimization with the Pitzer ion interaction equations in Microsoft Excel,1 a number of successful predictions were made for the solubility of simple mixtures of the chosen species. Currently, this thermodynamic framework is being programmed into HTWOS as the mechanism for determining the solid-liquid phase distributions for the chosen species, replacing their simple wash and leach factors. Starting from a variety of open literature sources, a collection of Pitzer parameters and species chemical potentials, as functions of temperature, was tested for consistency and accuracy by comparison with available experimental thermodynamic data (e.g., osmotic coefficients and solubility). Reconciliation of the initial set of parameter coefficients with the experimental data led to the development of the self-consistent set known as the HTWOS Pitzer database. Using Microsoft Excel to formulate the Gibbs energy minimization method and the multi-component Pitzer ion interaction equations, several predictions of the solubility of solute mixtures at various temperatures were made using the HTWOS Pitzer database coefficients. Examples of these predictions are shown in Figure 3 and Figure 4. A listing of the entire HTWOS Pitzer database can be found in RPP-RPT-50703. Currently, work is underway to install the Pitzer ion interaction model in HTWOS as the mechanism for determining the solid-liquid phase distributions of select waste constituents during tank retrievals and subsequent washing and leaching of the waste. Validation of the Pitzer ion interaction model in HTWOS will be performed with analytical laboratory data of actual tank waste. This change in HTWOS is expected to elicit shifts in mission criteria, such as mission end date and quantity of high-level waste glass produced by WTP, as predicted by HTWOS. These improvements to the speciation calculations in HTWOS, however, will establish a better planning basis and facilitate more effective and efficient future operations of the WTP. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford's Double-Shell Tank AY-102 Recovery Project - 17416

Since at least August 2012, Hanford Tank 241-AY-102 (AY-102) has been leaking from its primary tank into its secondary containment. A pumping plan was developed in 2013 to provide a path forward for recommended remediation actions to be implemented as part of the AY-102 Recovery Project. On March 21, 2014, the Washington State Department of Ecology issued Administrative Order No. 10618 requiring Washington River Protection Solutions and the United States Department of Energy to conduct actions related to and including the removal of waste from AY-102. The three parties agreed to resolve the appeal of the Administrative Order through a Settlement Agreement which addresses the remaining requirements and implements enforceable milestone dates, including initiation of waste retrieval by March 4, 2016 and completion of waste retrieval operations by March 4, 2017. The AY-102 Recovery Project was developed to address the Settlement Agreement requirements. While retrieval of waste from Single-Shell Tanks has been performed at Hanford for decades, retrieval from Double-Shell Tank AY-102 required adaptation of the existing technologies to a new environment on a larger scale than previously encountered. A significant number of obstructions and in-tank equipment limit accessibility to the high source term AY-102 waste and the location of the selected receiver tank required installation of an extensive, heavily-shielded above-ground transfer line. Despite countless challenges and obstacles encountered throughout, the project successfully completed system design, fabrication, installation, testing, and the first phase of operations within a highly compressed, aggressive schedule. Waste retrieval operations in AY-102 commenced on March 3, 2016 and the initial operating phase concluded on April 30. Additional sluicing capability was required to complete the mission and four Extended Reach Sluicers were installed to support the second operating phase, which began on December 8, 2016. As of December 31, 2016, approximately 97% of the original waste volume had been removed, resulting in an estimated remaining waste volume of about 75,000 liters. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of a Preliminary Performance Assessment to Support Single-Shell Tank Waste Retrieval - 19446

A preliminary Performance Assessment (PA) of Single-Shell Tank (SST) Waste Management Area A-AX (WMA A-AX) located at DoE's Hanford Site in southeastern Washington is being conducted to satisfy the requirements of the Hanford Federal Facility Agreement and Consent Order (HFFACO), as well as other Federal and State requirements of closure plans and permits. The WMA A-AX PA effort is assessing the fate, transport, and impacts of radionuclides and hazardous chemicals within residual wastes left in tanks, ancillary equipment, and facilities in their assumed closed configuration, and the subsequent risks to humans into the far future. WMA A-AX includes the 241-A Tank Farm (A Farm), the 241-AX Tank Farm (AX Farm), and the ancillary equipment associated with each Farm. There are six underground SSTs in A Farm, and four underground SSTs in AX Farm. Each of these SSTs have a storage capacity of 1,000,000 gallons. A complex waste transfer system of ancillary equipment supported the transfer and storage of waste within WMA A-AX SSTs. This ancillary equipment includes transfer lines, catch tanks, diversion boxes, vaults, valve pits, and other miscellaneous structures. This paper emphasizes the development of the PA effort focused on radiological impacts to meet the requirements for a closure authorization under DOE Order 435.1. Lessons learned from retrieval and development of a recently completed PA of the nearby Waste Management Area C (WMA C) led to the decision to develop a preliminary PA for WMA A-AX prior to initiation of retrieval efforts so that a site-specific risk management capability could be available to support anticipated retrieval decisions. The technical approach for the PA analysis includes developing both a process-level model using site-specific hydrogeological data, as well as a system-level model. The system model is being developed to facilitate uncertainty and sensitivity analyses being conducted in the PA effort. Preliminary results of the DOE Order 435.1 PA are evaluating potential impacts to the groundwater and air pathways to determine radiation exposure once radionuclides are released to the environment from residual waste after closure of the tank farm. To meet other analysis requirements in DOE Order 435.1, the PA effort must also evaluate potential radiological impacts from inadvertent intruder scenarios into the closed WMA A-AX facility. The results of the PA evaluation will be compared to performance objectives and measures in the DOE Order 435.1 to support retrieval and eventual closure decisions at WMA A-AX. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Tank Side Cesium Removal System Project and Technology Maturation Program - 19519

Washington River Protection Solutions (WRPS) is the Tank Operating Contractor (TOC) for the U.S. Department of Energy-Office of River Protection (DOE-ORP) on the Hanford Site. The Hanford Site stores an estimated 56 million gallons of mixed radioactive and chemically hazardous waste in large underground tanks. WRPS is in the process of designing the Tank Side Cesium Removal (TSCR) system to produce Low Activity Waste (LAW) from Hanford tank waste. The LAW will be transferred to the Waste Treatment and Immobilization Plant (WTP) LAW Vitrification Facility, where the hazardous constituents in the LAW will be immobilized in a durable glass waste form for disposal. The TSCR Project demonstrates a tank-side treatment system for providing feed to the WTP LAW Vitrification Facility. This system removes cesium from supernatant tank waste using non-elutable cesium ion exchange media to meet the applicable waste acceptance criteria for the WTP. In support of the project, a tailored Technology Maturation/Testing Plan (TMP) has been developed to identify principal Technology Elements (TEs) for the proposed process, designate Critical Technology Elements (CTEs), identify gaps in the existing knowledge base and identify the necessary activities to mature the technologies for successful deployment of TSCR. The project scope and technology maturation approach are presented. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Mercury Speciation of Hanford 241-AP-107 Tank Waste Samples - 20384

The concentration of key mercury species in the Hanford tank waste has not been previously measured. Based on process knowledge, an estimated inventory of 2,100 kg of mercury is assumed and was distributed in varied amounts across 149 single-shell tanks (SSTs) and 28 double-shell tanks (DSTs). Limited analyses of individual SSTs and DSTs for total mercury were all below detection, yielding upper limits in concentration estimates based solely on instrument detection limits, resulting in an uncertain mercury inventory for Hanford tanks. Accurate and reliable chemical speciation and quantification is desired to anticipate, predict, and abate the mass movements of various mercury species through the Hanford waste processing flowsheet. Highly sensitive separation and quantification methods for total, elemental, and monomethyl mercury species, in tank waste, have been developed at the Pacific Northwest National Laboratory's (PNNL) Radiochemical Processing Laboratory (RPL). A non-radiological environmental method to quantify mercury species has been adapted for application to Hanford tank 241-AP-107 raw supernatant feed, filtered feed, and cesium-decontaminated samples. These samples represent feed inventory and pretreatment process effluents prior to immobilization by vitrification. This method separates and preconcentrates total, elemental, and monomethyl mercury onto selective solid substrates with little-to-no radioactive background. The solid samples can then be released from strict radiological control, allowing for analytical work to be conducted in low-level radiological facilities. Separation of mercury species was demonstrated at PNNL's RPL in Richland, Washington before transport and analytical quantification using cold vapor atomic fluorescence spectrometry (CVAFS) at PNNL's Marine Science Laboratory (MSL) in Sequim, Washington. Additional studies were conducted to assess the stability of monomethyl mercury in distilled matrices and preconcentrated onto the Carbotrap{sup R} solid substrate to assess sample degradation over time during transport. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Tank Side Cesium Removal System Project and Technology Maturation Program - 20101

Washington River Protection Solutions (WRPS) is the Tank Operating Contractor (TOC) for the U.S. Department of Energy-Office of River Protection (DOE-ORP) on the Hanford Site. The Hanford Site stores an estimated 56 million gallons of mixed radioactive and chemically hazardous waste in large underground tanks. WRPS is in the process of designing the Tank Side Cesium Removal (TSCR) system to produce a Low Activity Waste (LAW) feed from existing mixed Hanford tank waste. The LAW will be transferred to the Waste Treatment and Immobilization Plant (WTP) LAW Vitrification Facility, where it will be immobilized in a durable glass waste form for disposal. The TSCR Project demonstrates a tank-side treatment system for providing feed to the WTP LAW Vitrification Facility. This system removes undissolved solids and cesium from tank waste supernatant using non-elutable ion exchange media to meet the applicable waste acceptance criteria for the WTP. In support of the project, technology testing has been performed to answer design questions and reduce risk. The project scope and technology testing approach are presented. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of a process for remediation of enriched uranium coolant tanks at AWE Aldermaston - 14520

Machining processes involving Enriched Uranium (EU) at the UK Atomic Weapons Establishment have historically required the use of a liquid coolant to ensure product quality and to provide protection against hazards associated with ignition of the EU swarf in the non-inert gloved air box atmosphere. This coolant is typically provided by closed circuit re-circulating systems utilising large volume tanks to contain the bulk coolant. Small losses of EU to the coolant tank are experienced during the machining process leading to accumulation over time. This is expected and appropriate measures are put in place to control such accumulations to ensure criticality safety during the operational phase. The original design intent made no specific provision for recovery of the EU as it was not expected to be required based on the anticipated losses and design lifetime of the tanks. However, in support of ongoing operations it has become necessary to develop a process to remediate out of service coolant tanks to recover the EU and to replace the coolant and some of the end-of-life tank components. Detailed optioneering has been undertaken to develop a process that addresses all the relevant hazards, including nuclear criticality safety. Non-destructive assay techniques have been developed to help determine the inventory of EU present and consequently the level of control required during the remediation process. This has led to the selection of favourable geometry collection vessels that not only afford significant defence-in-depth against criticality hazards during the remediation work but also satisfy interim storage requirements. These vessels may also be of interest to other operators. This paper presents an overview of the history of operation of the coolant tanks and proposed remediation process and provides an overview of the criticality safety case that has been developed to support it. It is anticipated that the remediation work will be undertaken before 2019 allowing the findings and lessons learnt (including validation of non-destructive assay results on expected hold up) to be reported at the next ICNC. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Effectiveness of Vapor Corrosion Inhibitors Under Elevated Chloride Conditions for Aboveground Storage Tank Application

The sand quality used to construct the tank pad is an important contributing factor to the rate of corrosion that occurs on the soil-side of the aboveground storage tanks (ASTs) floor plates. Clean sand that meets specific criteria provides the first line of defense for mitigation of tank floor corrosion. However, it has been observed that the sand quality used for some existing tanks differ greatly from the specifications provided in the API 651 standard; this could be partially due to initial sand quality not meeting the specification, and partially due to the environmental effects over time. For example, rain-water intrusion could lead to higher than the specified contents of corrosive species such as chloride. Tank operators are increasingly using vapor corrosion inhibitors (VCIs) either as a stand alone or in combination with cathodic protection (CP) for ASTs to mitigate soil-side corrosion. VCIs are delivered either through-thefloor or injected through the ports in the ring wall. Experimental studies were conducted to evaluate VCIs’ performance at elevated chloride concentrations and to study the effectiveness of the delivery methods under extreme chloride conditions. The experimental work found that VCI performance is robust and not compromised due to high chloride levels, such as 300 ppm or more. The work also showed that the through-the-floor VCI delivery method is more beneficial compared to the through-the-sand-pad method when tank pad corrosivity is elevated.

Shukla, Pavan K.↗

STATISTICAL ANALYSIS OF IN-SERVICE ULTRASONIC INSPECTION DATA OF WASTE TANKS AT THE SAVANNAH RIVER Site-25021

Liquid radioactive waste has been stored in large, underground carbon steel tanks of 4.92-million-liter capacity at the United States Department of Energy's Savannah River Site (SRS) in Aiken, South Carolina since the 1950s. The In-service inspection of the Savannah River Site High Level Waste tanks will be reviewed as well as Ultrasonic testing (UT) for detecting for general wall thinning, pitting and interface attack through accessible regions of the tanks. In-service inspection [1] of the Savannah River Site (SRS) High Level Waste (HLW) tanks is an essential element of a comprehensive structural integrity program. Inspection confirmed the effectiveness of chemistry and temperature controls used to preclude localized and general corrosion of the tanks. Ultrasonic testing is used to detect general wall thinning, pitting and interface attack, as well as vertically oriented cracks through inspection of a 21.59 cm (8.5-in.) wide strip extending over the accessible height of the primary tank wall.

Harris, Stephen P.↗