Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Specifiation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Spatiotemporal Analyses of Groundwater and Shoreline Cr(VI) Concentrations in the 100 Areas at Hanford

Cleanup efforts have been ongoing since the late 1990s to remediate contaminated waste sites and groundwater in the 100 Areas at the U.S. Department of Energy (DOE) Hanford Site. One of the primary contaminants of concern is hexavalent chromium (Cr(VI)), which was used as a corrosion inhibitor in cooling water for nuclear reactors that formerly operated along the shoreline of the Columbia River. Cleanup efforts have included 1) removal, treatment (as needed), and disposal of contaminated sediments; 2) in situ redox manipulation as a permeable reactive barrier; 3) pump-and-treat; 4) soil flushing; and 5) monitored natural attenuation. DOE’s annual groundwater monitoring reports document the significant reductions in Cr(VI) plume areas that have occurred over the past 10 years or more as a result of these cleanup efforts. The Record of Decision for the 100-HR-3 operable unit specified a cleanup level (CUL) for Cr(VI) in groundwater of 48 µg/L to protect human receptors, and a surface water CUL of 10 µg/L to protect aquatic organisms in the Columbia River. The Record of Decision did not specify point-of-compliance locations for the surface water CUL. Data for 2019 from the six groundwater operable units (OUs) in the 100 Areas indicate that the 48 μg/L groundwater CUL has been achieved in 100% of the wells in the 100-BC and 100-NR OUs, and in 89- 97% of the wells in the other OUs (100-KR, 100-HR-D, 100-HR-H, 100-FR). Data for 2019 indicate that 100% of the aquifer tubes monitored for Cr(VI) in the 100 Areas have concentrations below the 48 μg/L groundwater CUL. However, the 10 μg/L standard has not yet been consistently achieved for both inland groundwater monitoring wells and shoreline aquifer tubes. This report describes a series of data analyses performed to identify consistent relationships, if any, between inland well and shoreline Cr(VI) concentrations within the 100 Areas. To this end, select monitoring data for Cr(VI) measured in groundwater and aquifer tubes at the 100 Areas were analyzed for a 10-year period—2010 to 2019. Relationships between inland groundwater plumes and surface-water points of discharge in and along the Columbia River were examined through several analyses that included inland well and aquifer tube concentrations as a function of distance from the shoreline, evaluation of cumulative probability plots, trend analysis, correlation analysis, cluster analysis, and identification of plume trajectories for each of the 100 Areas. The analyses did not identify consistent relationships between inland groundwater Cr(VI) concentrations and shoreline concentrations within the 100 Areas due to several confounding factors influencing groundwater flow directions and Cr(VI) concentrations. The proximity of groundwater Cr(VI) plumes to the river, and the highly dynamic nature of the river, influence the transport behavior of the plumes and create challenges for quantifying attenuation of Cr(VI) between the inland monitoring wells and shoreline concentrations. Other factors contributing to temporal and spatial Cr(VI) concentrations, as supported by some of the data analyses, include the presence of vadose zone sources, variable sorption behavior, and complexities associated with Cr(VI) mass transfer between the upper and lower aquifers and their interactions with the river. Hence, monitoring to assess compliance with target CULs will need to be determined for each area individually since several factors influence Cr(VI) concentrations in the 100 Areas.

54 ENVIRONMENTAL SCIENCES↗

Best Practices Guide: Benchmarking Energy Efficiency in Laboratories

Purpose and Audience A wide spectrum of laboratory owners, ranging from universities to federal agencies, have explicit goals for energy efficiency and greenhouse gas reductions in their facilities. For example, new federal buildings and major renovations of existing buildings are to reduce fossil fuel-generated energy consumption by 90% in 2025, and 100% in 2030, compared with a 2003 baseline (FEMP n.d.). Minnesota SB2030 standard requires achieving an 80% reduction from the average building baseline for commercial, institutional, and industrial buildings (SB2030 n.d). A laboratory—new or existing—is much more likely to meet energy efficiency goals if quantitative metrics and targets are explicitly specified and tracked over the life cycle of the building, from design through construction, commissioning, operations, and renovations. If efficiency targets are not explicitly and properly defined, any additional capital costs or design time associated with attaining higher efficiencies can be difficult to justify relative to other priorities. The purpose of this guide is to provide guidance on how to specify and compute energy efficiency metrics and benchmarks for laboratories, at the whole-building as well as the system level. The information in this guide can be used to incorporate quantitative metrics and targets into new construction or retrofit of existing facilities. For information on strategies and technologies to achieve energy efficiency, the reader is referred to I2SL resources, including technology best practice guides and case studies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Concurrent Optimization of Capital Cost and Expected O&M

Concentrating solar power (CSP) technologies can utilize heat from concentrated sunlight from a field of tracking mirrors to generate electricity, reform fuel, provide process heat, or augment fossil plant heat sources. Electricity-generating power tower systems focus light from thousands of independent heliostats onto a thermal receiver, which uses the focused light to warm a heat transfer fluid (HTF), typically, a molten nitrate salt. The HTF is then sent to a power generation cycle or diverted into thermal energy storage (TES) for later use. Thermal storage is – in principle – a straightforward proposition. However, optimal utilization of a TES resource is complex and multi-faceted: thermal energy may be dispatched to produce electricity immediately upon first availability, or thermal energy may be reserved for next-day peak periods at risk of filling storage and dumping energy, or a portion of the thermal energy can be reserved to maintain equipment temperatures, reducing power cycle startup time, etc. Many possible dispatch permutations variously emphasize producing peak power, operating through transients, expediting daily startup, etc. The best operation strategy can change day-to-day throughout the year, depending on the weather and market pricing forecasts. The project we describe in this report develops a software package that allows users to explore design optimization, operations decisions, and performance characterization of concentrating solar power tower plants. Users interface with the tool through a scripting language, and results are reported in time series tables, plots, runtime logs, and design outputs. Users choose from a list of variables such as tower height, solar multiple, design-point irradiance, thermal storage size, etc., and specify information about the system using a list of parameters. The software can then optimize the specified variables to reduce the cost of energy produced by the system while meeting certain production requirements, accounting for uncertain weather and electricity price forecasts, and correcting for equipment failures or repair time. The software we develop is the first comprehensive design tool of its kind to incorporate all of these aspects while being deployed as open source.

14 SOLAR ENERGY↗

MACCS Theory Manual

This report describes the models of the MACCS computer code as presented in MACCS Version 3.10.0. The purpose of MACCS is to simulate the impact of severe accidents at nuclear power plants on the surrounding environment. MACCS has been developed by Sandia National Laboratories for the U.S. Nuclear Regulatory Commission. From a given release of radioactive material into the atmosphere, MACCS estimates the extent and magnitude of radiological contamination, offsite doses, protective actions, socioeconomic impacts and costs, and health effects. Since the weather at the time of an accident is not predictable, MACCS supports various sampling options to run a representative set of simulations to evaluate weather variability. MACCS simulates atmospheric transport with a straight-line Gaussian plume segment model. From the estimated air and ground concentrations, MACCS models dose projections through several dose exposure pathways. These exposures can be offset by protective actions during the emergency response and long-term recovery of the accident. MACCS users directly specify the evacuation and sheltering area, while other protective actions (e.g., relocation, farmland restrictions, decontamination) are based on user-specified dose or concentration limits. While protective actions help reduce dose accumulation, they also cause social and economic impacts. MACCS models the extent of displaced individuals and land contamination, and the cost of offsite property damage, economic disruptions, and various accident expenditures caused by protective actions. Finally, from the dose accumulation, MACCS estimates early and stochastic health effects according to dose-response models. The purpose of consequence analyses is to be able to understand and estimate the impact of nuclear accidents. Consequence analysis is an essential tool to inform determinations of adequate protection of the public, to understand nuclear power hazards, to measure the value of regulations, and to help us appreciate the importance of nuclear safety. As such, MACCS has a variety of regulatory uses including environmental analyses (10 CFR 51.53, 52.47), regulatory cost-benefit analyses, backfit analyses (10 CFR 50.109), consequence analysis studies such as SOARCA (NUREG-1935), Level 3 PRA studies, and risk-informing of emergency planning (10 CFR 50 App. E and 50.47). This report updates the previous MACCS theory manual (NUREG/CR-4691 Vol. 2; Chanin, Sprung, Ritchie, & Jow, 1990) and accompanies the MACCS User's Guide (SAND-2021-1588) that describes the use and input requirements of the graphical user interface of MACCS known as WinMACCS. The MACCS User's Guide is also a reference guide that describes data input file formats, describes various software components in the MACCS code suite, and provides a set of example tutorials for running WinMACCS. Also, soon to be published is a MACCS input parameter guidance report (NUREG/CR-7270) that provides technical bases for commonly used MACCS input values. This page left blank

97 MATHEMATICS AND COMPUTING↗

Mixing Cell Model: A One-Dimensional Numerical Model for Assessment of Water Flow and Contaminant Transport in the Unsaturated Zone

This report describes the Mixing Cell Model code, a one dimensional model for water flow and solute transport in the unsaturated zone under steady state or transient flow conditions. The model is based on the principles and assumptions underlying mixing-cell model formulations. The unsaturated zone is discretized into a series of independent mixing cells. Each cell may have unique hydrologic, lithologic, and sorptive properties. Ordinary differential equations describe the material (water and solute) balance within each cell. Water-flow equations are derived from the continuity equation, assuming that unit gradient conditions exist at all times in each cell. Pressure gradients are considered implicitly through model discretization. Unsaturated hydraulic conductivity and moisture contents are determined by the material specific moisture-characteristic curves. Solute-transport processes include explicit treatment of advective processes, first order chain decay, and linear sorption reactions. Dispersion is addressed through implicit and explicit dispersion. Implicit dispersion is an inherent feature of all mixing-cell models and originates from the formulation of the problem in terms of mass balance around fully mixed volume elements. Expressions are provided that relate implicit dispersion to the physical dispersion of the system. Two FORTRAN codes were developed to solve the water flow and solute-transport equations: (1) the Mixing Cell Model for Flow (MCMF) solves transient water-flow problems and (2) the Mixing Cell Model for Transport (MCMT) solves the solute-transport problem. The transient water-flow problem is typically solved first by estimating the water flux through each cell in the model domain as a function of time using the MCMF code. These data are stored in either ASCII or binary files that are later read by the solute transport code (MCMT). Code output includes solute pore water concentrations, water and solute inventories in each cell and at each specified output time, and water and solute fluxes through each cell and specified output time. Computer run times for coupled transient water flow and solute transport were typically several seconds on a 2 GHz Intel Pentium IV desktop computer. The model was benchmarked against analytical solutions and finite element approximations to the partial differential equations (PDE) describing unsaturated flow and transport. Differences between the maximum solute flux estimated by the mixing cell model and the PDE models were typically less than two percent. This revision includes an option for a fixed concentration lower boundary condition for diffusive fluxes for versions 020321 and later.

54 ENVIRONMENTAL SCIENCES↗

Background Information on the Power Quality Requirements in IEEE Std 1547-2018

The revised Institute of Electrical and Electronics Engineers (IEEE) 1547-2018, Standard for Interconnection and Interoperability of Distributed Energy Resources with Associated Electric Power Systems Interfaces, was published in April 2018. This standard is one of the foundational documents in the United States needed for integrating distributed energy resources (DERs), including solar energy systems, and energy storage systems with the electric distribution grid. The revised standard contains 11 chapters (clauses) and 8 annexes that comprise 136 pages. The revision is significantly different from the 2003 version, and it contains new concepts and new technical requirements. Each clause specifies information or requirements that apply to certain aspects that are important to the interconnection of DERs to the electric power system. Implementing the requirements necessitates a careful study of the underlying technical concepts and requires appropriate information to calculate relevant settings and configurations. This document provides informative material on the requirements related to electrical power quality in IEEE Std 1547-2018, with the intent to equip the reader with basic knowledge and background information to improve understanding and use of the requirements specified.

14 SOLAR ENERGY↗

SECARB-USA: Data Quality Methodology

SECARB-USA Deliverable 4.2.1 utilizes the outputs from the Needs Assessment (Subtask 2.1) to develop a data quality methodology. Many types of data are needed to evaluate a site for technical and financial viability. Several inventories of data types have been produced (for example NETL, 2010). The objective here is to organize the data types so that the needs met are specified. From this cross index (Table 1 in the Appendix), it will be possible in future tasks to (1) determine, on a site-specific basis, how much of each data type is required at each stage of a project to meet the need, and conversely (2) to further specify and define the data collection methods applied such that the data are tailored to fit that need. Derivative tables can then be developed to semi-quantitively evaluate the extent to which need is critical for early go/no-go decision points, or if it is more important than average, requiring faster or larger capitalization and spend to meet the need. In an additional step, the current availability of data for a site can be semi-quantitively assessed. From the table of data criticality and the table of data availability, site-specific cost for meeting the data needs can be determined, and allow a pre-permit spend estimated for a portfolio of projects.

54 ENVIRONMENTAL SCIENCES↗

FECM/NETL CO 2 Transport Cost Model (2022): Description and User’s Manual

The FECM/NETL CO 2 Transport Cost Model (CO 2 _T_COM) is an Excel spreadsheet model that calculates the cost of transporting CO 2 from the beginning to the end of a pipeline. This document provides two main functions. First, the document describes the equations and algorithms that are used by the model to calculate technical quantities (such as the minimum inner pipe diameter needed to transport a user-specified CO 2 mass flow rate a specified distance) and engineering-economic quantities (such as capital costs, operating costs and cash flows). Second, the document is a user’s manual for the model that describes the procedures the user must follow to run the model. The document also describes input variables and output variables (i.e., results) for the model.

42 ENGINEERING↗

Characterization of the Fusion Zone in Laser Beam Welds on SS304L

Designing a welded joint requires consideration of the welding process, component/assembly structure and weld geometry, material composition, properties, and desired joint performance. The designer must also specify a set of acceptance criteria used to evaluate the welds. This study was conducted to support the design team responsible for specifying the spot weld profile by investigating the relationship between weld process parameters and the weld geometry and properties to further inform design optimization. The subjects of this study are two thin stainless steel 304L (SS304L) components joined by Laser Beam Welding (LBW). The components are the Housing, which contains flexible circuitry, and the Cover that protects the circuitry during handling, installation, and under service loads. Figure 1 illustrates coupon versions of the Cover and Housing used to simulate the interface between these components for weld testing. These coupon representations of assembly components were designed to match the material and relevant geometry related to the welded joint while other features not relevant to the welded joint are excluded.The objective of this study was to characterize the sensitivity of the weld geometry and mechanical properties to the input weld parameters to inform further Finite Element Analysis (FEA) efforts in balancing joint strength against assembly deformation caused by the welding process. Characterization was accomplished by varying laser welding parameters around the current design values and measuring weld geometry on the cross-sections. Nanoindentation with a spherical and flat-ended tip was used on polished section cuts of the weld to obtain direct estimates of the stress-strain response of the Fusion Zone (FZ) for comparison to the Base Metal (BM).

42 ENGINEERING↗

An Assessment of Potential Dose Impacts from External Contamination on Naval Reactors Facility Waste Canisters (Special Analysis)

This Special Analysis (SA) was performed to address a request by Naval Reactors Facility (NRF) Waste Programs for a permanent exception to limits of removable surface contamination on the exterior of waste canisters shipped to the Remote-Handled Low-Level Waste (RHLLW) Disposal Facility as specified in the waste acceptance criteria (WAC) (PLN-5446). The purpose of this SA is to determine if the NRF-requested levels for removable surface contamination on the exterior of all NRF waste canisters is within the bounds of the current performance assessment (PA). This was done by calculating the groundwater all-pathways dose contribution from surface contamination on the exterior of NRF canisters for the following cases: (1) the exteriors of all NRF waste canisters are contaminated to the 10 CFR 835 Appendix D allowable limits in the current WAC, and (2) the exteriors of all NRF waste canisters are contaminated to the limits requested by NRF Waste Programs. Dose impacts for each case were compared to each other and to the all pathways dose for the PA base case. Dose impacts were also compared to the all pathways dose limit specified in DOE O 435.1. A simple assessment of the potential impacts of the increase in surface contamination using the NRF-requested limits on the biotic, air, and inadvertent intruder pathways was also performed. Based on the results of this SA, the increase in canister exterior contamination limits requested by NRF are well within the bounds of the current PA and will not result in a violation of performance objectives. The results also show the increased limits do not reflect or necessitate a fundamental change to the PA conceptual model, nor a change to the way exterior contamination is not included in PA dose calculations. Therefore, it is recommended the NRF request for an exception to the current limits for external surface contamination be accepted and the revised limits for NRF-generated waste canisters be added to the WAC. The monitoring plan will also be revised to identify external canister contamination as a potential mobile source term that may be detected by monitoring earlier than potential releases from waste. The PA, composite analysis (CA), closure plan, and PA/CA maintenance plan do not require revision. Recommendations are also included for inclusion of NRF procedures used to limit water pool radionuclide variability (and thus canister surface contamination variability) to the waste generator certification process.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

US HL-LHC Accelerator Upgrade Project, Acceptance Criteria Part A: MQXFA Magnet

This document specifies the functional requirements for the MQXFA magnet readapted for the American contribution. If all the requirements specified in this document are met, then the U.S. HL-LHC AUP MQXFA deliverables will be accepted by CERN for the HL-LHC project. Another separate document will be issued by the American contribution for the MQXFA cold mass functional requirements. Please note that the definition of threshold as it is being used by the American contribution is not the same as objective, according to the HL-LHC quality policy.

42 ENGINEERING↗

Generation of Fission Fragment Angular Momentum

In the last two years FREYA has been updated to study fission fragment angular momentum generation. We have also introduced integer and half integer spins, not specified in FREYA previously, and required to specify fragments more precisely. With these changes, FERYA still conserves energy as well as linear and angular momentum throughout the fission event. It is now possible to use FREYA to study a number of correlated quantities related to fragment spin, some of which can be directly measured. The spin-spin correlation was a major point of discussion at the Fission Fragment Angular Momentum workshop in Seattle in June 2022.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

DLR Calculation Engine Interoperability Profile: A Project for the TOGETs Task Force

This document contains a detailed interoperability profile outlining how the components of the CIM can be used to implement DLR in support of the two use cases identified in the Use Case Document. An interoperability profile is defined by the Smart Electric Power Alliance (SEPA) as a document that “specifies standards-based requirements for interfaces or applications that are accepted by the user-community, testing authorities, and other stakeholders. It specifies configuration options within a standard’s requirements sufficient to deliver the desired level of interoperability and functionality.” To that end, this document is not in itself a standard, nor has it been approved by any formal body. Rather, it is an example of how to implement the CIM standard and has been reviewed by industry, including transmission operators and DLR vendors.

24 POWER TRANSMISSION AND DISTRIBUTION↗

FECM/NETL CO 2 Transport Cost Model (2023): Description and User’s Manual

The FECM/NETL CO 2 Transport Cost Model (CO 2 _T_COM) is an Excel spreadsheet model that calculates the cost of transporting CO 2 from the beginning to the end of a pipeline. This document provides two main functions. First, the document describes the equations and algorithms that are used by the model to calculate technical quantities (such as the minimum inner pipe diameter needed to transport a user-specified CO 2 mass flow rate a specified distance) and engineering-economic quantities (such as capital costs, operating costs and cash flows). Second, the document is a user’s manual for the model that describes the procedures the user must follow to run the model. The document also describes input variables and output variables (i.e., results) for the model. The model can be accessed at this URL: https://www.netl.doe.gov/energy-analysis/details?id=d3086f60-278d-4e97-a649-8e4d5ce5e93c

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Primer on Nuclear "Recoil" Data

For many years the ENDF-6 format has existed to contain evaluated nuclear data. One primary driver for the format and the data is neutron transport calculations. Evaluated data can be processed by a code like NJOY into either continuous energy form (ACE format) for Monte Carlo codes like MCNP or into multi-group form (NDI tables) for deterministic codes like Partisn. The reaction cross sections are found in the MF 3 section of the ENDF-6 format. If the reaction produces one or more neutrons as outputs, then secondary neutron data must also be given in MF 4,5 or 6 sections of the format. Energy and angular distributions for the output neutrons must be given in one of several available formats. The most general formats are found in MF 6. MF 4 is for angular distributions, MF 5 is for Energy distributions, and MF 6 contains both. In recent years, more interest has developed in the other output particles (i.e., the “recoil” particles) from neutron induced reactions. This has been driven by interest in charged particle transport and in more specialized partial kermas. ( A separate total neutron kerma has been available for a long time.) Partial kermas are a breakdown of the Kinetic Energy Released into the MAterial by output particle or by neutron reaction. The sum of the partial kermas should be equal to the total kerma on a group-wise basis. The ENDF-6 format is general enough for these new data requirements. Ideally, evaluated data would exist for every output particle (including the secondary neutrons) from every neutron-induced reaction. In the MF 6 format section, data for multi-particle outputs may be entered using the LAW =1 option. This option explicitly allows energy and angular output distributions for each particle produced in the reaction. Such information should preserve the balance between partial kermas and the total kerma at the groupwise level as well as the individual particle averaged energies. For simpler 2-body reactions, LAW = 2 is available. This allows the evaluation to specify only enough data to specify the 2-body reaction fully. Such a simplification does not exist for 3 (or more) body breakups. A simplified form of LAW 2, i.e., LAW 3, also exists to generate approximate recoil output distributions in the absence of full data. However, evaluated data does not generally exist at this fine granularity for reactions involving more than 2 output particles ( e.g., the 3-body break-up reaction). When the multi-body detailed output distribution data is not available, LAW=6 may be employed in NJOY. LAW 6 produces approximate output distributions for all the particles produced in the reaction. Just like in the 2-body case, the smaller particles will generally carry off more energy. At any particular energy, the balance between the sum of the partial kermas and the total kerma will not necessarily be preserved. However, the average energy of each output particle from a reaction is preserved.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Acceptance Criteria Part B: LMQXFA cold mass and cryo-assembly

This document specifies the acceptance criteria for the LMQXFA cold mass and cryoassembly. If all the requirements specified in this document are met, then the U.S. HL-LHC AUP LMQXFA and LQXFA deliverables will be accepted by Please note that the definition of threshold as it is being used by the American contribution is not the same as objective, according to the HL-LHC quality policy.

43 PARTICLE ACCELERATORS↗

FECM/NETL Hydrogen Pipeline Cost Model (2024): Description and User’s Manual

The FECM/NETL Hydrogen Pipeline Cost Model (H2_P_COM) estimates costs for transporting gaseous hydrogen in a pipeline from a source, such as a hydrogen production facility, to a final destination which may be a user of the hydrogen or a distribution center where hydrogen in the pipeline is diverted to multiple end users. This document provides two main functions. First, the document describes the equations and algorithms that are used by the model to calculate technical quantities (such as the minimum inner pipe diameter needed to transport a user-specified H 2 mass flow rate a specified distance) and engineering-economic quantities (such as capital costs, operating costs, and cash flows). Second, the document is a user’s manual for the model that describes the procedures the user must follow to run the model. The model can be accessed at this URL: https://www.netl.doe.gov/energy-analysis/details?id=db897190-8e26-40b1-9535-ee78ac934193

08 HYDROGEN↗

End-Use Savings Shapes Measure Documentation: Thermostat Control for Load Shifting in Large Offices

This documentation focuses on a single end-use savings shape measure - thermostat control for load shifting. The thermostat control for load shifting measure applies heating and cooling temperature setpoint adjustment for pre-conditioning before the peak window. The measure takes daily peak load schedule inputs generated by the method "Dispatch Schedule Generation" described in the "Supplemental Documentation: Dispatch Schedule Generation for Demand Flexibility Measures" to determine the start time of the peak window, and then adjusts the thermostat cooling or heating setpoints by a specified offset value from original schedules to precool or preheat the space , for a specified length of time before the start of peak window, and thus shifts load in the peak window to the pre-conditioning period. The measure is flexible and allows users to adjust the heating and cooling offset values and length of pre-conditioning period, but for this study, the load shifting strategy is applied as pre-cooling only (adjusting only cooling setpoints). The default adjustment for cooling setpoints is set to -1 degrees Celsius , and the default duration of pre-cooling is 1 hour. This measure is applicable to large offices equipped with electric HVAC system, which account for approximately 8.72% of the ComStock floor area. The thermostat control for load shifting measure demonstrates -1% daily peak demand reduction and 0% total site energy savings (0 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗