Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Space Environments Effects Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Integrated Systems Health Management for Space Exploration

Integrated Systems Health Management (ISHM) is a system engineering discipline that addresses the design, development, operation, and lifecycle management of components, subsystems, vehicles, and other operational systems with the purpose of maintaining nominal system behavior and function and assuring mission safety and effectiveness under off-nominal conditions. NASA missions are often conducted in extreme, unfamiliar environments of space, using unique experimental spacecraft. In these environments, off-nominal conditions can develop with the potential to rapidly escalate into mission- or life-threatening situations. Further, the high visibility of NASA missions means they are always characterized by extraordinary attention to safety. ISHM is a critical element of risk mitigation, mission safety, and mission assurance for exploration. ISHM enables: In-space maintenance and repair; a) Autonomous (and automated) launch abort and crew escape capability; b) Efficient testing and checkout of ground and flight systems; c) Monitoring and trending of ground and flight system operations and performance; d) Enhanced situational awareness and control for ground personnel and crew; e) Vehicle autonomy (self-sufficiency) in responding to off-nominal conditions during long-duration and distant exploration missions; f) In-space maintenance and repair; and g) Efficient ground processing of reusable systems. ISHM concepts and technologies may be applied to any complex engineered system such as transportation systems, orbital or planetary habitats, observatories, command and control systems, life support systems, safety-critical software, and even the health of flight crews. As an overarching design and operational principle implemented at the system-of-systems level, ISHM holds substantial promise in terms of affordability, safety, reliability, and effectiveness of space exploration missions.

Uckun, Serdar↗

Integration of an expert system into a user interface language demonstration

The need for a User Interface Language (UIL) has been recognized by the Space Station Program Office as a necessary tool to aid in minimizing the cost of software generation by multiple users. Previous history in the Space Shuttle Program has shown that many different areas of software generation, such as operations, integration, testing, etc., have each used a different user command language although the types of operations being performed were similar in many respects. Since the Space Station represents a much more complex software task, a common user command language--a user interface language--is required to support the large spectrum of space station software developers and users. To assist in the selection of an appropriate set of definitions for a UIL, a series of demonstration programs was generated with which to test UIL concepts against specific Space Station scenarios using operators for the astronaut and scientific community. Because of the importance of expert system in the space station, it was decided that an expert system should be embedded in the UIL. This would not only provide insight into the UIL components required but would indicate the effectiveness with which an expert system could function in such an environment.

Stclair, D. C.↗

Disinfectants for spacecraft applications - An overview

The review of disinfectants for use on manned missions emphasizes the need for contamination control to prevent the detrimental effects of bacteria growth on crew health. Microbial control is possible by means of biocides, but the selected product has to meet stringent toxicity requirements for the small environments in spacecraft. The testing and evaluation is described of four biocide candidates: hydrogen peroxide, quaternary ammonium compounds, iodine, and glutaraldehyde. The effectiveness of the disinfectants are analyzed in terms of the ability to treat typical microbial counts from Skylab missions in a closed environment. It is shown that many biocide candidates are not compatible with the ECLSS, water-recovery management, and air-revitalization subsystems of the Space Station Freedom. The use of hydrogen peroxide is proposed with a secondary stronger agent for microbial spills from biological experiments.

Koenig, David W.↗

Polymer matrix composites on LDEF experiments M0003-9 and M0003-10

Over 250 polymer matrix composites were exposed to the natural space environment on Long Duration Exposure Facility (LDEF) experiments M0003-9 and 10. The experiments included a wide variety of epoxy, thermoplastic, polyimide, and bismalimide matrix composites reinforced with graphite, glass, or organic fibers. A review of the significant observations and test results obtained to date is presented. Estimated recession depths from atomic oxygen exposure are reported and the resulting surface morphologies are discussed. The effects of the LDEF exposure on the flexural strength and modulus, short beam shear strength, and coefficient of thermal expansion of several classes of bare and coated composites are reviewed. Lap shear data are presented for composite-to-composite and composite-to-aluminum alloy samples that were prepared using different bonding techniques and subsequently flown on LDEF.

Steckel, Gary L.↗

Evaluation of various cleaning methods to remove bacillus spores from spacecraft hardware materials

A detailed study was made of the biological cleaning effectiveness, defined in terms of the ability to remove bacterial spores, of a number of methods used to clean hardware surfaces. Aluminum (Al 6061) and titanium (Ti 6Al-4V) were chosen for the study as they were deemed the two materials most likely to be used in spacecraft extraterrestrial sampler construction. Metal coupons (1 cm x 2.5 cm) were precleaned and inoculated with 5.8 x 10(3) cultivable Bacillus subtilis spores, which are commonly found on spacecraft surfaces and in the assembly environments. The inoculated coupons were subsequently cleaned using: (1) 70% isopropyl alcohol wipe; (2) water wipe; (3) multiple-solvent flight-hardware cleaning procedures used at the Jet Propulsion Laboratory (JPL); (4) Johnson Space Center-developed ultrapure water rinse; and (5) a commercial, semi-aqueous, multiple-solvent (SAMS) cleaning process. The biological cleaning effectiveness was measured by agar plate assay, sterility test (growing in liquid media), and epifluorescent microscopy. None of the cleaning protocols tested completely removed viable spores from the surface of the aluminum. In contrast, titanium was capable of being cleaned to sterility by two methods, the JPL standard and the commercial SAMS cleaning process. Further investigation showed that the passivation step employed in the JPL standard method is an effective surface sterilant on both metals but not compatible with aluminum. It is recommended that titanium (Ti 6Al-4V) be considered superior to aluminum (Al 6061) for use in spacecraft sampling hardware, both for its potential to be cleaned to sterilization and for its ability to withstand the most effective cleaning protocols.

Spores, Bacterial/metabolism↗

Ground Demonstration on the Autonomous Docking of Two 3U CubeSats Using a Novel Permanent-Magnet Docking Mechanism

Small spacecraft autonomous rendezvous and docking is an essential technology for future space structure assembly missions. A novel magnetic capture and latching mechanism is analyzed that allows for docking of two CubeSats without precise sensors and actuators. The proposed magnetic docking hardware not only provides the means to latch the CubeSats but it also significantly increases the likelihood of successful docking in the presence of relative attitude and position errors. The simplicity of the design allows it to be implemented on many CubeSat rendezvous missions. A CubeSat 3-DOF ground demonstration effort is on-going at NASA Langley Research Center that enables hardware-in-the loop testing of the autonomous approach and docking of a follower CubeSat to an identical leader CubeSat. The test setup consists of a 3 meter by 4 meter granite table and two nearly frictionless air bearing systems that support the two CubeSats. Four cold-gas on-off thrusters are used to translate the follower towards the leader, while a single reaction wheel is used to control the attitude of each CubeSat. An innovative modified pseudo inverse control allocation scheme was developed to address interactions between control effectors. The docking procedure requires relatively high actuator precision, a novel minimal impulse bit mitigation algorithm was developed to minimize the undesirable deadzone effects of the thrusters. Simulation of the ground demonstration shows that the Guidance, Navigation, and Control system along with the docking subsystem leads to successful docking under 3-sigma dispersions for all key system parameters. Extensive simulation and ground testing will provide sufficient confidence that the proposed docking mechanism along with the choosen suite of sensors and actuators will perform successful docking in the space environment.

Pei, Jing↗

Space Launch System Aeroacoustic Wind Tunnel Test Results

Characterization of accurate launch vehicle unsteady aerodynamics is critical for component and secondary structure vibroacoustic design. For the National Aeronautics and Space Administration (NASA) Space Launch System (SLS), aeroacoustic environments have been derived primarily through sub-scale wind tunnel testing. Both optical techniques and high frequency pressure measurements have been utilized across multiple testing facilities and numerous vehicle configurations to develop a range of preliminary and detailed environments. As the vehicle has matured and evolved, the data collected from each subsequent configuration has allowed for comparison studies which isolate the effects of certain outer mold line (OML) features on measured fluctuating pressure levels. This paper presents observations on some of those effects for features which include abort system protuberances, various fairings geometries, interstage flanges, and multibody interactions between a central core and fall away boosters. These features, and the flow conditions produced by them, are broadly applicable to many launch vehicle configurations.

Steva, Thomas B.↗

Inducer Hydrodynamic Forces in a Cavitating Environment

Marshall Space Flight Center has developed and demonstrated a measurement device for sensing and resolving the hydrodynamic loads on fluid machinery. The device - a derivative of the six-component wind tunnel balance - senses the forces and moments on the rotating device through a weakened shaft section instrumented with a series of strain gauges. This rotating balance was designed to directly measure the steady and unsteady hydrodynamic loads on an inducer, thereby defining the amplitude and frequency content associated with operating in various cavitation modes. The rotating balance was calibrated statically using a dead-weight load system in order to generate the 6 x 12 calibration matrix later used to convert measured voltages to engineering units. Structural modeling suggested that the rotating assembly first bending mode would be significantly reduced with the balance s inclusion. This reduction in structural stiffness was later confirmed experimentally with a hammer-impact test. This effect, coupled with the relatively large damping associated with the rotating balance waterproofing material, limited the device s bandwidth to approximately 50 Hertz Other pre-test validations included sensing the test article rotating assembly built-in imbalance for two configurations and directly measuring the assembly mass and buoyancy while submerged under water. Both tests matched predictions and confirmed the device s sensitivity while stationary and rotating. The rotating balance was then demonstrated in a water test of a full-scale Space Shuttle Main Engine high-pressure liquid oxygen pump inducer. Experimental data was collected a scaled operating conditions at three flow coefficients across a range of cavitation numbers for the single inducer geometry and radial clearance. Two distinct cavitation modes were observed symmetric tip vortex cavitation and alternate-blade cavitation. Although previous experimental tests on the same inducer demonstrated two additional cavitation modes at lower inlet pressures, these conditions proved unreachable with the rotating balance installed due to the intense dynamic environment. The sensed radial load was less influenced by flow coefficient than by cavitation number or cavitation mode although the flow coefficient range was relatively narrow. Transition from symmetric tip vortex to alternate-blade cavitation corresponded to changes in both radial load magnitude and radial load orientation relative to the inducer. Sensed moments indicated that the effective load center moved downstream during this change in cavitation mode. An occurrence of "higher+rdex cavitation" was also detected in both the stationary pressures and the rotating balance data although the frequency of the phenomena was well above the reliable bandwidth of the rotating balance. In summary the experimental tests proved both the concept and device s capability despite the limitations and confirmed that hydrodynamically-induced forces and moments develop in response to the unbalanced pressure field, which is, in turn, a product of the cavitation environment.

Skelley, Stephen E.↗

Technical Challenges in Reliable Microelectronics Packaging of Microelectromechanical Systems (MEMS) for Space Applications

MEMS have shown a significant promise in the last decade for a variety of applications such as air-bag, pressure sensors, accelerometer, microgyro, chemical sensors, artificial nose, etc. Standard semiconductor microelectronics packaging needs the integrated circuits (IC) to be protected from the harsh environment, and provide electrical communication with the other parts of the circuit, facilitate thermal dissipation efficiently, and impart mechanical strength to the silicon die. Microelectronics packaging involves wafer dicing, bonding, lead attachment, encapsulation to protect from the environment, electrical integrity, and package leak tests to assure the reliable IC packaging technology. Active elements or microstructures in MEMS devices often interfaces with the hostile environment where packaging leak tests and testing of such devices using chemical and mechanical parameters will be very difficult and expensive. Packaging of MEMS is significantly complex as they serve to protect from the environment and microstructures interact with the same environment to measure or affect the desired physical or chemical parameters. The most of the silicon circuitry is sensitive to temperature, moisture, magnetic field, light, and electromagnetic interference. The package must then protect the on-board silicon circuitry while simultaneously exposing the microsensor to the effect it measures to assure the packaging technology of MEMS. MEMS technology has a major application in developing a microspacecraft for space systems provided reliability of MEMS packaging technology is sufficiently addressed. This MEMS technology would eventually miniaturize many of the components of the spacecraft to reach the NASA's goal by building faster, cheaper, better, smaller spacecraft to explore the space more effectively. This paper discusses the latest developments in the MEMS technology and challenging technical issues in the packaging of hermetically sealed and non-hermetically sealed MEMS sensor devices for microspacecraft applications.

Ramesham, Rajeshuni↗

A hydroponic system for microgravity plant experiments

The construction of a permanently manned space station will provide the opportunity to grow plants for weeks or months in orbit for experiments or food production. With this opportunity comes the need for a method to provide plants with a continuous supply of water and nutrients in microgravity. The Capillary Effect Root Environment System (CERES) uses capillary forces to maintain control of circulating plant nutrient solution in the weightless environment of an orbiting spacecraft. The nutrient solution is maintained at a pressure slightly less than the ambient air pressure while it flows on one side of a porous membrane. The root, on the other side of the membrane, is surrounded by a thin film of nutrient solution where it contacts the moist surface of the membrane. The root is provided with water, nutrients and air simultaneously. Air bubbles in the nutrient solution are removed using a hydrophobic/hydrophilic membrane system. A model scaled to the size necessary for flight hardware to test CERES in the space shuttle was constructed.

short duration↗

Sheath effects observed on a 10 meter high voltage panel in simulated low earth orbit plasma

A large (1m x 10m) flat surface of conductive material was biased to high voltage (+ or - 3000 V) to simulate the behavior of a large solar array in low earth orbit. The model array was operated in a plasma environment of 1,000 to 1,000,000/cu cm, with sufficient free space around it for the resulting plasma sheaths to develop unimpeded for 5-10 meters into the surrounding plasma. Measurements of the resulting sheath thickness were obtained. The observed thickness varied approximately as V to the 3/4 power and N to the 1/2 power. This effect appears to limit total current leakage from the test array until sheath dimensions exceed about 1 meter. Total leakage current was also measured with the array.

Mccox, J. E.↗

Durability of spacecraft materials

Research efforts are reviewed on the space durability of materials, including radiation effects on polymer matrix composites and films, dimensional stability of polymer matrix composites and tension-stabilized cables, and thermal control coatings. Research to date has concentrated on establishing a fundamental understanding of space environmental effects on current graphite-reinforced composites and polymer systems, and development of analytical models to explain observed changes in mechanical, physical, and optical properties. As a result of these research efforts, new experimental facilities have been developed to simulate the space environment and measure the observed property changes. Chemical and microstructural analyses have also been performed to establish damage mechanisms and the limits for accelerated testing. The implications of these results on material selection and system performance are discussed and additional research needs and opportunities in the area of tougher resin/matrix and metal/matrix composites are identified.

Darrel R. Tenney↗

The NASA/JPL Evaluation of Oxygen Interactions with Materials-3 (EOIM-3)

The deleterious effects of hyperthermal atomic oxygen (AO) found in low-earth-orbit (LEO) environments on critical flight materials has been known since early shuttle flights. This corrosive effect is of considerable concern because it compromises the performance and longevity of spacecraft/satellite materials deployed for extended periods in LEO. The NASA Evaluation of Oxygen Interactions with Materials-3 (EOIM-3) experiment served as a testbed for a variety of candidate flight materials for space assets. A total of 57 JPL test specimens were present in six subexperiments aboard EOIM-3. In addition to a number of passive exposure materials for flight and advanced technology programs, several subexperiments were included to provide data for understanding the details of atomic oxygen interactions with materials. Data and interpretations are presented for the heated tray, heated strips, solar ultraviolet exposure, and scatterometer subexperiments, along with a detailed description of the exposure conditions experienced by materials in the various experiments. Mass spectra of products emerging from identical samples of a (sup 13)C-enriched polyimide polymer (chemically equivalent to Kapton) under atomic oxygen bombardment in space and in the laboratory were collected. Reaction products unambiguously detected in space were (sup 13)CO, NO, (sup 12)CO2, and (sup 13)CO2. These reaction products and two others, H2O and (sup 12)CO, were detected in the laboratory, along with inelastically scattered atomic and molecular oxygen. Qualitative agreement was seen in the mass spectra taken in space and in the laboratory; the agreement may be improved by reducing the fraction of O2 in the laboratory molecular beam.

Brinza, David E.↗

Modeling and simulation for space medicine operations: preliminary requirements considered

The NASA Space Medicine program is now developing plans for more extensive use of high-fidelity medical simulation systems. The use of simulation is seen as means to more effectively use the limited time available for astronaut medical training. Training systems should be adaptable for use in a variety of training environments, including classrooms or laboratories, space vehicle mockups, analog environments, and in microgravity. Modeling and simulation can also provide the space medicine development program a mechanism for evaluation of other medical technologies under operationally realistic conditions. Systems and procedures need preflight verification with ground-based testing. Traditionally, component testing has been accomplished, but practical means for "human in the loop" verification of patient care systems have been lacking. Medical modeling and simulation technology offer potential means to accomplish such validation work. Initial considerations in the development of functional requirements and design standards for simulation systems for space medicine are discussed.

Non-programmatic↗

Requirements for Modeling and Simulation for Space Medicine Operations: Preliminary Considerations

The NASA Space Medicine program is now developing plans for more extensive use of high-fidelity medical Simulation systems. The use of simulation is seen as means to more effectively use the limited time available for astronaut medical training. Training systems should be adaptable for use in a variety of training environments, including classrooms or laboratories, space vehicle mockups, analog environments, and in microgravity. Modeling and simulation can also provide the space medicine development program a mechanism for evaluation of other medical technologies under operationally realistic conditions. Systems and procedures need preflight verification with ground-based testing. Traditionally, component testing has been accomplished, but practical means for "human in the loop" verification of patient care systems have been lacking. Medical modeling and simulation technology offer potential means to accomplish such validation work. Initial considerations in the development of functional requirements and design standards for simulation systems for space medicine are discussed.

Dawson, David L.↗

Aerothermal Effects of Cavities and Protuberances for High-Speed Sample Return Capsules

Extraterrestrial sample return is a growing component of solar system exploration. Currently, four missions, Stardust, 1 Muses-C, 2 Genesis, and Mars Sample Return, are under development that employ sample return as a prime component of the mission architecture. Respectively, these missions will return samples from the tail of a comet, an asteroid, the solar wind, and, Mars. An important component of these missions and the focus of this paper is the design of the sample return capsule (SRC). The purpose of the SRC is to safely return to Earth any gathered samples for terrestrial analysis. The two major design constraints for any SRC are as follows: 1) it must be able to survive a high-speed Earth entry (11 km/s to as a high as 15 km/s), 2) the mass of the SRC must be as small as possible. Because the SRC mass is carried from Earth to the sample sight and back, the SRC mass is a strong driver in the mission mass budget. Further, for the Mars Sample Return Capsule, planetary protection is another constraint. For this capsule, the probability of planetary contamination at Earth due to an SRC failure at entry must be minimal. For an SRC, a possible failure mechanism is severe local heating as a result of cavities and or protuberances in the SRC forebody heatshield. For example, the Apollo Command Module had a number of cavities and protuberances as part of the baseline designs Wind-tunnel tests of models containing small cavities and protuberances showed severe local heating augmentations in the vicinity of these surface discontinuities.4-5 As another example, the Genesis SRC forebody heat-shield contains penetrations (cavities) to mount the vehicle to the carrier bus. It is expected that these penetrations will also experience a severe local heating environment. A concern is that the large thermal gradients may produce sufficient thermal stress to cause local mechanical failure of the heatshield. Penetrations to the forebody heat-shield can also result from damage at vehicle integration, during launch, or during transportation of the sample return capsule from earth to the sample site and back. For example, the Starting SRC was damaged near the shoulder during the heatshield integration process producing a local surface discontinuity. Also, the Starting SRC traverses through the tail of a comet and is in space for 7 years. Thus, damage to the heatshield as a result of micrometeroid impact is a concern. Finally, it is difficult to characterize the effects of these potential heatshield singularities with ground-test facilities. Either detailed simulation or a dedicated flight test is required.

Olynick, David↗

Power Hibernation for Low-Cost Solar Powered Lunar Missions

Because the surface of the Moon drops to cryogenic temperatures, no solar-powered lunar spacecraft have reliably operated beyond a single lunar day. Passive thermal control cannot keep a spacecraft sufficiently warm for the 354-hour lunar night, and active thermal control requires a dramatic increase in battery mass at the expense of payload mass. Extreme conditions seen on the lunar surface suggest a radioisotope solution is ideal, but mass, cost, and schedule are inconsistent with low-cost frequent flight intent of the commercial lunar payload services (CLPS) program. To solve the issue of lunar night survivability without radioisotope sources of power and heat, a lunar power hibernation approach is being developed at the Glenn Research Center, which exploits the ability of common 18650 Lithium-ion cells to passively survive cryogenic freeze-thaw cycles and recover without apparent performance degradation. A key aspect of this hibernation approach is the use of cryogenically operable electronics that safely manage the restoration of the battery thermal environment at lunar dawn. A spacecraft utilizing this strategy will operate into the lunar night on batteries until the state of charge or spacecraft temperature reaches a predetermined threshold. At this point, systems are shut down and the battery is isolated from the main bus to prevent charge or discharge during the freezing and thawing transitions. The system remains passive until lunar dawn, where temperatures can reach as low as 50 K. All electronics must be tolerant to these conditions. When the solar arrays are finally illuminated at lunar dawn, the main bus power electronics will initiate a “cold start” and begin regulating array power. The main bus electronics must be designed to operate at cryogenic temperatures. Array power is used to warm the battery and passive electronics back to operational temperatures. Once batteries are returned to normal temperatures, diagnostics and precharging is performed, as needed, and the battery is reconnected. The overall spacecraft system reboots and returns to nominal operations until lunar night returns. To assure that we can develop batteries suited for many hibernation freeze/thaw cycles, STMD Space Technology Research Grant Program (STRG) has selected two principal investigators that will thoroughly characterize of the Li-ion cell through the freeze-thaw process, investigate degradation mechanisms, and identify potential diagnostic techniques. STMD STRG is also funding an investigation of Gallium-Nitride semiconductors for cryogenic power applications. This work includes physics-informed modeling that considers cryogenic conductivity, carrier mobility, and quantum effects that govern semiconductor performance at cryogenic temperatures. These models can enable engineers to develop accurate cryogenic simulation models that assist in the design of power controls stable over the entire lunar surface temperature range. Meanwhile, Glenn is performing cryogenic testing of batteries and electronics, establishing design guidelines for power applications in extreme cold lunar environment, and potentially developing a hibernation technology demonstrator. The hibernation approach will enable low-cost lunar robotic missions to extend their operating lifetime to many months while minimizing development costs and impact on payload capacity. The need for cryogenically operable electronics is restricted to only main bus power and battery controls, as the majority of systems simply need to passively tolerate cryogenic temperatures. This allows developers to continue to exploit the cost savings of legacy and COTS hardware with minimum modification. For these reasons, lunar power hibernation is a viable near-term solution for lunar night survivability for solar powered commercial landers.

Space power↗