Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Scintillator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Balloon measurements of cosmic ray protons and helium over half a solar cycle 1965-1969.

Evaluation of differential energy spectra for protons and helium covering the energy range from 100 to 260 MeV/nucleon obtained from balloon flights made each summer (1965 to 1969) at Churchill, Manitoba, with the aid of a Geiger-tube hodoscope operated in conjunction with two scintillation elements used to measure dE/dx and E. Supplementary data from balloon flights at Minneapolis, Minn., and Sioux Falls, S. Dak. and from calibration exposures to protons and electrons were used to define backgrounds and to verify the predicted detector response. The observed proton spectra are characterized over a wide range of energy (30 to 300 MeV) by a simple relationship between cosmic-ray intensity J and kinetic energy T: J = AT. The helium spectra also follow this law at solar maximum but rise less steeply near solar minimum. This characteristic behavior can be interpreted in terms of a simple model in which convection is balanced by adiabatic deceleration.-

Rygg, T. A.↗

ATS-F millimeter wave propagation experiment data processing.

Review of the data processing program for the Applications Technology Satellite (ATS-F) scheduled for launch in 1973. The program consists of: (1) short term processing, which utilizes analog data recording and produces amplitude scintillation and time-frequency correlation studies; and (2) long term processing, which utilizes digitally recorded data to provide hourly and daily statistical output functions. The data acquisition and processing program planned for the ATS-F experiment provides a highly automated environment which emphasizes the unique requirements for the characterization of the propagation medium in the frequency bands required for the next generation of space communication systems.

Ippolito, L. J.↗

Techniques for gamma rays.

The detecting systems used in high energy astrophysics are generally more similar to particle detectors than to optical devices. The basic design of the gamma ray instrument depends on whether the energy range is below about 10 MeV and therefore in the region where the Compton effect predominates in the absorption of the gamma-rays, or above that energy where electron-positron pair production is most important. The most usual approach to the detector system in the lower of the two energy intervals is to use a scintillation counter in the center of the detector system to absorb the photons and permit a measure of their energy, and to surround it by another detector which is employed as an active anticoincidence shield to discriminate against charged particles. In the gamma-ray interval above about 10 MeV, the very low flux of gamma rays and the high particle background has directed the development of high energy gamma-ray telescopes towards complicated techniques and large detector arrays. As a result, several investigators have now turned to the spark chamber as the heart of a detector system. Generally, it is surrounded by an anticoincidence system and is triggered by a counter telescope.

Fichtel, C. E.↗

The quiet-time spectra of cosmic-ray electrons of energies between 10 and 200 MeV observed on OGO-5.

Measurement of spectra of cosmic-ray electrons of energies between 10 and 200 MeV over a one-year period starting 1968 March. The measurement was made with a detector system on board the OGO-5 satellite. The instrument consists of a solid-state dE/dx detector, a total-energy CsI detector, a gas Cerenkov threshold detector, and two scintillation guard counters. Time periods during which no solar-flare events were recorded were selected for the study. It was found that during these quiet periods there were numerous intensity variations of the electron flux. These variations, which are seen only below 25 MeV, do not show marked correlation with any solar or interplanetary-medium parameters. The flux of the electrons of energies above 25 MeV, on the other hand, showed a gradual decrease over the one-year period, paralleling the neutron monitor intensity. The parameter describing this long-term modulation is almost independent of the rigidity of the electrons in the reported energy range. The physical implication of the finding is discussed.

L'Heureux, J.↗

Search for X rays from the planet Jupiter.

Actively collimated balloon-borne scintillation counters employing a special phoswich anticoincidence technique were flown a total of 5 times from Palestine, Texas. Jupiter was observed for a total of 133 min, and an upper limit to the flux of X rays present at the observation time is .016 X rays/sq cm sec in the energy range 30-100 keV. Three separate calculations are made to estimate the flux of Jovian X rays at the earth. These estimates range from .000000001 to .1 X rays/sq cm sec in the energy range 30-100 keV. It is concluded that, since there was no decametric emission at the time of the flight and there had been no significant solar activity for several days prior to the flight, no X rays were being generated at the time of the observation.

Hurley, K. C.↗

Superconducting magnetic spectrometer for cosmic ray nuclei.

This paper describes the design, calibration, and operation of a magnetic spectrometer for particle astronomy. The spectrometer consists of a superconducting magnet, optical spark chambers, scintillation detectors, and associated electronics. The instrument has been flown in a balloon gondola to 4.8 g/sq cm residual atmosphere, where it was used to analyze the charge and differential rigidity spectra of primary nuclei from 5 to 100 GeV/c.

Smith, L. H.↗

The energy spectrum of primary cosmic ray electrons from 2 GeV to 200 GeV.

Use of a balloon-borne counter telescope with a gas Cerenkov counter to measure the energy of primary cosmic ray electrons between 2 and 200 GeV. Electrons are identified by the characteristic electron-photon shower which they produce in a 15 radiation length deep stack of high-Z material interleaved with scintillation counters. Calibrations with monoenergetic electrons up to 14 GeV and monoenergetic protons up to 28 GeV from accelerators are used to develop criteria to statistically separate electrons from proton-induced events. The results from six balloon flights (total exposure time 63 hours) are combined to obtain the electron energy spectrum. Up to about 30 GeV, the spectrum measured in this experiment can be directly checked with calibrations and agrees well with results from other experiments. Above this energy, the flux reported in the present work is somewhat higher than the determinations reported by most other authors. An apparent flattening of the energy spectrum above 50 GeV is not regarded as significant. There is no evidence for a steepening of the spectrum at energies below 200 GeV.

Fanselow, J. L.↗

The shadow band phenomenon.

Observation of shadow bands during the solar eclipse of Mar. 7, 1970. Data were gathered by recording onto magnetic tape of the output from six collimated photocells whose spectral responses ranged from the ultraviolet to the infrared, and by visual and mechanical measurement of the orientation and motion of the bands. The recorded data were later processed using the output from a frequency spectrum analyzer. Most of the energy of the shadow bands ranges between 1 and 25 Hz, and appears not unlike plots of scintillation spectra. The onset, amplitude, and duration of the shadow bands seem to be spectrally related to the limb darkening of the sun's photosphere. Other results of the experiment conclusively indicate that the shadow band phenomenon is a manifestation of atmospheric turbulence in the form of air packets of different density from that of their environment (density schlieren), made visible by the light from the crescent sun.

Quann, J. J.↗

Response of TlCl /I,Be/ crystals to energetic ionizing radiation.

The response of a 3.8-cm TlCl(I,Be) crystal to 8 GeV negative pions is reported. A comparison is also made with the response of a similar CsI(Tl) crystal to the same incident radiation. In addition, the pulse shape and resolution characteristics of a 7.6-cm TlCl(I,Be) crystal, excited by positrons in the energy range 50 to 130 MeV, are reviewed. It is concluded that thallous chloride shows promise of being an excellent scintillating material for the detection and energy determination of high energy photons and charged particles.

Farukhi, M. R.↗

Techniques in balloon X-ray astronomy.

Since the first balloon observation of the Crab Nebula balloon data have provided much information on the positions, spectra, time variability and pulsed nature of localized sources, and on the spectrum and isotropy of diffuse galactic and universal components. Measurements are limited to energies above about 20 keV by atmospheric attenuation at 2 to 3 g/sq cm depth and to below several hundred keV by detector sensitivity. Detectors usually consist of large-area Na I or Cs I scintillation counters with anticoincidence collimators for rejection of charged particles and scattered X-rays. Proportional counters are occasionally used at lower energies and solid-state detectors are used where extreme energy resolution is important. The instruments require a pointing capability on the order of 1.0 to 0.1 deg, depending on the collimator aperture. Digital data is either recorded on board or telemetered using a PCM technique.

Peterson, L. E.↗

Improved format for radiocardiographic data

Technique involves introduction of radioactive sample into antecubital vein. Scintillation crystal mounted in collimating housing views portion of right and left hearts. As radioactive sample passes through heart, counting rate is measured by crystal and recorded on strip chart. Data is insensitive to geometric effects and other parameters.

Dimeff, J.↗

Simultaneous L-band and VHF ionospheric fading effects at the geomagnetic equator

Simultaneous observations of ionspheric fading of 1550 MHz and 136 MHz radio waves from the ATS-5 spacecraft were recorded on the geomagnetic equator at Ancon, Peru. The observations were made during a period around the 1971 spring equinox; they show fades as great as 27 db at 136 MHz, and 6 db at 1550 MHz. The general characteristics of the scintillation signatures at the two frequencies are discussed with emphasis on comparison of the two frequencies with respect to rates and depths of fades. Typical statistical distributions of signal levels are also presented from which time availabilities of the signals relative to the median levels can be derived.

Sessions, W. B.↗

Ionospheric fading effects on the equatorial zone

Microwave fading of space communication channels in the equatorial region is caused by the effects of the disturbed ionosphere. Three dimensional plots of percentage occurence of very high frequency scintillation effects shown as a function of time of day and week of the year prove that, most fading occurs at nighttime and around the weeks of the equinox. The magnitude of fading at the equator violates existing scattering theories and must be taken into account when designing a microwave communication link to space.

Golden, T. S.↗

Feasibility of an on-line fission-gas-leak detection system

Calculations were made to determine if a cladding failure could be detected in a 100-kW zirconium hydride reactor primary system by monitoring the highly radioactive NaK coolant for the presence of I-131. The system is to be completely sealed. A leak of 0.01 percent from a single fuel pin was postulated. The 0.364-MeV gamma of I-131 could be monitored on an almost continuous basis, while its presence could be varified by using a longer counting time for the 0.638-MeV gamma. A lithium-drifted germanium detector would eliminate radioactive corrosion product interference that could occur with a sodium iodide scintillation detector.

Lustig, P. H.↗

Expected gamma-ray emission spectra from the lunar surface as a function of chemical composition

The gamma rays emitted from the moon or any similar body carry information on the chemical composition of the surface layer. The elements most easily measured are K, U, Th and major elements such as O, Si, Mg, and Fe. The expected fluxes of gamma ray lines were calculated for four lunar compositions and one chondritic chemistry from a consideration of the important emission mechanisms: natural radioactivity, inelastic scatter, neutron capture, and induced radioactivity. The models used for cosmic ray interactions were those of Reedy and Arnold and Lingenfelter. The areal resolution of the experiment was calculated to be around 70 to 140 km under the conditions of the Apollo 15 and 16 experiments. Finally, a method was described for recovering the chemical information from the observed scintillation spectra obtained in these experiments.

Reedy, R. C.↗

RALPH: An online computer program for acquisition and reduction of pulse height data

A background/foreground data acquisition and analysis system incorporating a high level control language was developed for acquiring both singles and dual parameter coincidence data from scintillation detectors at the Radiation Counting Laboratory at the NASA Manned Spacecraft Center in Houston, Texas. The system supports acquisition of gamma ray spectra in a 256 x 256 coincidence matrix (utilizing disk storage) and simultaneous operation of any of several background support and data analysis functions. In addition to special instruments and interfaces, the hardware consists of a PDP-9 with 24K core memory, 256K words of disk storage, and Dectape and Magtape bulk storage.

Davies, R. C.↗

Hodoscope Measurements of the Spectrum of Cosmic Electrons Between 10 Gev and 100 Gev

In an attempt to reduce divergences among independent measurements of the electron spectrum above 10 GeV, electrons were detected with the aid of a large hodoscope which incorporates 8 trays of Geiger tubes and 10 scintillation counters into a calorimeter containing 33 radiation lengths of lead. This instrument was thoroughly calibrated up to 9 GeV with an electron synchrotron and was flown twice at a depth of 5 g/sq cm for a total of 30 hours at ceiling. Electron showers at 10 GeV are completely contained within the calorimeter where their ionization is sampled twelve times, and where hodoscope trays provide information on the geometrical distribution of shower particles. Electrons appeared in a histogram of number of events vs. a X2 measure of goodness of fit to electron shower curves as a clearly resolved peak standing well above the nuclear background. The initial ionization and the lateral spread of shower particles are consistent with those of calibration electrons. In contrast, the behavior of the nuclear continuum associated with minimum ionizing incident particles is different from that of calibration electrons but similar to that of nuclear events associated with incident helium nuclei. The differential electron spectrum from 10 to 100 GeV was obtained.

Meegan, C. A.↗

Measured and calculated fast neutron spectra in a depleted uranium and lithium hydride shielded reactor

Measurements of MeV neutron were made at the surface of a lithium hydride and depleted uranium shielded reactor. Four shield configurations were considered: these were assembled progressively with cylindrical shells of 5-centimeter-thick depleted uranium, 13-centimeter-thick lithium hydride, 5-centimeter-thick depleted uranium, 13-centimeter-thick lithium hydride, 5-centimeter-thick depleted uranium, and 3-centimeter-thick depleted uranium. Measurements were made with a NE-218 scintillation spectrometer; proton pulse height distributions were differentiated to obtain neutron spectra. Calculations were made using the two-dimensional discrete ordinates code DOT and ENDF/B (version 3) cross sections. Good agreement between measured and calculated spectral shape was observed. Absolute measured and calculated fluxes were within 50 percent of one another; observed discrepancies in absolute flux may be due to cross section errors.

Lahti, G. P.↗