Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SINGLE IONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Experimentally Determined Plasma Parameters in a 30 cm Ion Engine

Single planar Langmuir probes and fiber optic probes are used to concurrently measure the plasma properties and neutral density variation in a 30cm diameter ion engine discharge chamber, from the immediate vicinity of the keeper to the near grid plasma region. The fiber optic probe consists of a collimated optical fiber recessed into a double bore ceramic tube fitted with a stainless steel light-limiting window. The optical fiber probe is used to measure the emission intensity of excited neutral xenon for a small volume of plasma, at various radial and axial locations. The single Langmuir probes, are used to generate current-voltage characteristics at a total of 140 spatial locations inside the discharge chamber. Assuming a maxwellian distribution for the electron population, the Langmuir probe traces provide spatially resolved measurements of plasma potential, electron temperature, and plasma density. Data reduction for the NSTAR TH8 and TH15 throttle points indicates an electron temperature range of 1 to 7.9 eV and an electron density range of 4e10 to le13 cm(sup -3), throughout the discharge chamber, consistent with the results in the literature. Plasma potential estimates, computed from the first derivative of the probe characteristic, indicate potential from 0.5V to 11V above the discharge voltage along the thruster centerline. These values are believed to be excessively high due to the sampling of the primary electron population along the thruster centerline. Relative neutral density profiles are also obtained with a fiber optic probe sampling photon flux from the 823.1 nm excited to ground state transition. Plasma parameter measurements and neutral density profiles will be presented as a function of probe location and engine discharge conditions. A discussion of the measured electron energy distribution function will also be presented, with regards to variation from pure maxwellian. It has been found that there is a distinct primary population found along the thruster centerline, which causes estimates of electron temperature, electron density, and plasma potential, to err on the high side, due this energetic population. Computation of the energy distribution fimction of the plasma clearly indicates the presence of primaries, whose presence become less obvious with radial distance from the main discharge plume.

near grid plasma↗

FTIR, Micro-Raman and Ellipsometry Studies on Silicon Oxynitride Layers Synthesized by Low Energy Ion Implantation

Single crystal silicon were implanted at room temperature with {sup 16}O{sub 2}{sup +} and {sup 14}N{sub 2}{sup +} 30 keV ions in 1:1 ratio with fluences of 2.5x10{sup 17}, 5x10{sup 17}, 7.5x10{sup 17} and 1x10{sup 18} ions-cm{sup -2} to form silicon oxynitride layers. Rapid thermal annealing (RTA) of these samples was carried out at temperature of 623, 873 and 1173 K in nitrogen ambient for 5 min. Fourier transform infrared (FTIR), Micro-Raman and ellipsometry measurements were performed on RTA samples to investigate the structure and phase. The FTIR studies show that the structures of ion-beam synthesized oxynitride layers are strongly dependent on total ion-fluence and annealing temperature. The Micro-Raman studies on annealing revealed formation of partially amorphous oxygen and nitrogen rich silicon oxynitride structures for lower and higher ion fluences respectively with crystalline silicon beneath it. From the ellipsometry studies, the refractive index of the ion beam synthesized layers were found to be in 1.54-1.96 range.

36 MATERIALS SCIENCE↗

Robustness of Semi-Superjunction 4H-SiC Power DMOSFETs to Single-Event Burnout from Heavy Ion Bombardment

We compare the failure mechanism and performance of a silicon carbide (SiC) semi-superjunction (semi-SJ) power DMOSFET against pure SJ and conventional DMOSFET when struck by a single heavy ion. The Single-Event Burnout (SEB) failure mechanism was identified as the thermal runaway from second breakdown resulting in mesoplasma formation. The semi-SJ design shifts the mesoplasma location from the drift/substrate interface seen in the control device structures to a location along the center of the P-pillar and closer towards the DMOSFET surface, thus significantly improving the SEB threshold voltage. The SEB threshold voltage varies with pillar width and ratio of pillar thickness to drift layer thickness. A maximum value of SEB threshold voltage is reached when the pillar to drift layer ratio is 0.9 and the pillar width is 2.4 μm. The semi-SJ SEB/breakdown voltage ratio is 100% and 13% higher than the pure SJ and conventional DMOSFET, respectively. Using a new figure of merit (FOM), which accounts for the tradeoff between SEB threshold voltage and on-state performance, we find that the SiC semi-SJ DMOSFET achieves a FOM that is 1.8 and 8 times higher than SJ and conventional DMOSFET, respectively, making the semi-SJ a competitive candidate for radiation hardened applications.

SiC↗

Mechanical Stress Induced Current Focusing and Fracture in Grain Boundaries

Solid state electrolytes (SSEs) with garnet structures and chemical composition Li 7 La 3 Zr 2 O12 (LLZO) are being actively considered as the electrolyte for next-generation lithium ion batteries. These LLZO-based ceramic SSEs are polycrystalline and possess distinct grain-interior/grain-boundary (GI/GB) microstructure. Lithium dendrite growth through these GI and GB domains is considered to be the largest bottleneck preventing their successful implementation. Dendrite growth has been observed to occur predominantly within the GB regions. While this would be expected if the GB regions were more ionically conductive than the GI regions, there is significant disagreement over the relative conductivities of these two regions. The present work demonstrates that dendrite growth can occur preferentially in the GB regions even when the GI regions have higher ionic conductivity. Electrochemical potential changes induced by mechanical stress within the GI and GB domains reveals that the magnitude of effective stress induced current density within the elastically softer GB is larger than in the mechanically stiffer GI, which leads to enhanced lithium deposition in GB and subsequent dendrite growth. Finally, the present work additionally examines the impact of applied current density and grain size on current focusing in the GB regions, and also finds that SSE fractures initiate from the GB regions.

25 ENERGY STORAGE↗

Double ion production in mercury thrusters

The development of a model which predicts doubly charged ion density is discussed. The accuracy of the model is shown to be good for two different thruster sizes and a total of 11 different cases. The model indicates that in most cases more than 80% of the doubly charged ions are produced from singly charged ions. This result can be used to develop a much simpler model which, along with correlations of the average plasma properties, can be used to determine the doubly charged ion density in ion thrusters with acceptable accuracy. Two different techniques which can be used to reduce the doubly charged ion density while maintaining good thruster operation, are identified as a result of an examination of the simple model. First, the electron density can be reduced and the thruster size then increased to maintain the same propellant utilization. Second, at a fixed thruster size, the plasma density, temperature and energy can be reduced and then to maintain a constant propellant utilization the open area of the grids to neutral propellant loss can be reduced through the use of a small hole accelerator grid.

Peters, R. R.↗

Thermodynamic Data to 20,000 K For Monatomic Gases

This report contains standard-state thermodynamic functions for 50 gaseous atomic elements plus deuterium and electron gas, 51 singly ionized positive ions, and 36 singly ionized negative ions. The data were generated by the NASA Lewis computer program PAC97, a modified version of PAC91 reported in McBride and Gordon. This report is being published primarily to document part of the data currently being used in several NASA Lewis computer programs. The data are presented in tabular and graphical format and are also represented in the form of least-squares coefficients. The tables give the following data as functions of temperature : heat capacity, enthalpy, entropy Gibbs energy, enthalpy of formation, and equilibrium constant. A brief discussion and a comparison of calculated results are given for several models for calculating ideal thermodynamic data for monatomic gases.

Gordon, Sanford↗

Discharge Chamber Plasma Structure of a 30-cm NSTAR-Type Ion Engine

Single Langmuir probe measurements are presented over a two-dimensional array of locations in the near Discharge Cathode Assembly (DCA) region of a 30-cm diameter ring cusp ion thruster over a range of thruster operating conditions encompassing the high-power half of the NASA throttling table. The Langmuir probe data were analyzed with two separate methods. All data were analyzed initially assuming an electron population consisting of Maxwellian electrons only. The on-axis data were then analyzed assuming both Maxwellian and primary electrons. Discharge plasma data taken with beam extraction exhibit a broadening of the higher electron temperature plume boundary compared to similar discharge conditions without beam extraction. The opposite effect is evident with the electron/ion number density as the data without began, extraction appears to be more collimated than the corresponding data with beam extraction. Primary electron energy and number densities are presented for one operating condition giving an order of magnitude of their value and the error associated with this calculation.

Herman, Daniel A.↗

Dose Control System in the Optima XE Single Wafer High Energy Ion Implanter

Photoresist outgassing can significantly compromise accurate dosimetry of high energy implants. High energy implant even at a modest beam current produces high beam powers which create significantly worse outgassing than low and medium energy implants and the outgassing continues throughout the implant due to the low dose in typical high energy implant recipes. In the previous generation of high energy implanters, dose correction by monitoring of process chamber pressure during photoresist outgassing has been used. However, as applications diversify and requirements change, the need arises for a more versatile photoresist correction system to match the versatility of a single wafer high energy ion implanter. We have successfully developed a new dosimetry system for the Optima XE single wafer high energy ion implanter which does not require any form of compensation due to the implant conditions. This paper describes the principles and performance of this new dose system.

43 PARTICLE ACCELERATORS↗

Extraction of Plutonium-Containing Microcrystals from Hanford Soil using a Focused Ion Beam for Single-Crystal X-ray Diffraction Analysis

Herein we report the successful use of a focused ion beam/scanning electron microscope (FIB/SEM) to prepare microsamples of radioactive single-crystals for X-ray diffraction analysis. This technique was used to extract and analyze crystalline Pu-containing particles as small as 28 µm3 from Hanford soil taken from the 216-Z-9 waste crib which were then crystallographically characterized using single-crystal X-ray diffraction (SCXRD) to confirm the cubic structure of PuO2. As a systematic proof of concept, the technique was first tested using UO2 crystals milled into cubic shapes with approximate volumes 4620, 1331, 125, 8 and 1 µm3, respectively, in order to empirically determine the crystal size limits for characterization by a laboratory-based diffractometer with a sealed tube Mo or Ag anode X-ray source and a charge-coupled device (CCD) detector.

microcrystals, Plutomium, focused ion beam/scannin↗

Fundamental processes in the expansion, energization, and coupling of single- and multi-Ion plasmas in space: Laboratory simulation experiments

We have conducted a laboratory investigation into the physics of plasma expansions and their associated energization processes. We studied single- and multi-ion plasma processes in self-expansions, and included light and heavy ions and heavy/light mixtures to encompass the phenomenological regimes of the solar and polar winds and the AMPTE and CRRES chemical release programs. The laboratory experiments provided spatially-distributed time-dependent measurements of total plasma density, temperature, and density fluctuation power spectra with the data confirming the long-theorized electron energization process in an expanding cloud - a result that was impossible to determine in spaceborne experiments (as e.g., in the CRRES program). These results provided the missing link in previous laboratory and spaceborne programs. confirming important elements in our understanding of such solar-terrestrial processes as manifested in expanding plasmas in the solar wind (e.g., CMES) and in ionospheric outflow in plasmaspheric fluctuate refilling after a storm. The energization signatures were seen in an entire series of runs that varied the ion species (Ar', Xe', Kr' and Ne'), and correlative studies included spectral analyses of electrostatic waves collocated with the energized electron distributions. In all cases wave energies were most intense during the times in which the suprathermal populations were present, with wave intensity increasing with the intensity of the suprathermal electron population. This is consistent with theoretical expectations wherein the energization process is directly attributable to wave particle interactions. No resonance conditions were observed, in an overall framework in which the general wave characteristics were broadband with power decreasing with increasing frequency.

Szuszczewicz, E. P.↗

Radiation damage by light- and heavy-ion bombardment of single-crystal LiNbO₃

In this work, a battery of analytical methods including in situ RBS/C, confocal micro-Raman, TEM/STEM, EDS, AFM, and optical microscopy were used to provide a comparative investigation of light- and heavy-ion radiation damage in single-crystal LiNbO₃. High (~MeV) and low (~100s keV) ion energies, corresponding to different stopping power mechanisms, were used and their associated damage events were observed. In addition, sequential irradiation of both ion species was also performed and their cumulative depth-dependent damage was determined. It was found that the contribution from electronic stopping by high-energy heavy ions gave rise to a lower critical fluence for damage formation than for the case of low-energy irradiation. Such energy-dependent critical fluence of heavy-ion irradiation is two to three orders of magnitude smaller than that for the case of light-ion damage. In addition, materials amorphization and collision cascades were seen for heavy-ion irradiation, while for light ion, crystallinity remained at the highest fluence used in the experiment. The irradiation-induced damage is characterized by the formation of defect clusters, elastic strain, surface deformation, as well as change in elemental composition. In particular, the presence of nanometric-scale damage pockets results in increased RBS/C backscattered signal and the appearance of normally forbidden Raman phonon modes. The location of the highest density of damage is in good agreement with SRIM calculations. (author)

36 MATERIALS SCIENCE↗

Ion transport through single-walled carbon nanotubes: Effects of electric field and fixed surface charge

The ion permeation trends for an aqueous sodium chloride solution through negatively charged carbon nanotubes under the simultaneous effects of a concentration gradient and an electric field using Molecular Dynamics simulations is investigated. A two-stage ion transport process was observed that resulted in a tunable effective ion flux toward the low concentration reservoir wherein the first stage resembled an electric-field assisted counter-ion (sodium) migration to the downstream reservoir for a short period of time followed by a second stage consisting of diffusion-driven electrolyte transport governed by the strength of the Donnan potential formed by the fixed charge on the nanotube.

Chemistry↗

Chimera Spectrum Diagnostics for Peptides Using Two-Dimensional Partial Covariance Mass Spectrometry

The rate of successful identification of peptide sequences by tandem mass spectrometry (MS/MS) is adversely affected by the common occurrence of co-isolation and co-fragmentation of two or more isobaric or isomeric parent ions. This results in so-called `chimera spectra’, which feature peaks of the fragment ions from more than a single precursor ion. The totality of the fragment ion peaks in chimera spectra cannot be assigned to a single peptide sequence, which contradicts a fundamental assumption of the standard automated MS/MS spectra analysis tools, such as protein database search engines. This calls for a diagnostic method able to identify chimera spectra to single out the cases where this assumption is not valid. Here, we demonstrate that, within the recently developed two-dimensional partial covariance mass spectrometry (2D-PC-MS), it is possible to reliably identify chimera spectra directly from the two-dimensional fragment ion spectrum, irrespective of whether the co-isolated peptide ions are isobaric up to a finite mass accuracy or isomeric. We introduce ‘3-57 chimera tag’ technique for chimera spectrum diagnostics based on 2D-PC-MS and perform numerical simulations to examine its efficiency. We experimentally demonstrate the detection of a mixture of two isomeric parent ions, even under conditions when one isomeric peptide is at one five-hundredth of the molar concentration of the second isomer.

47 OTHER INSTRUMENTATION↗

BioWires: Conductive DNA Nanowires in a Computationally-Optimized, Synthetic Biological Platform for Nanoelectronic Fabrication

DNA is an ideal template for a biological nanowire-it has a linear structure several atoms thick; it possesses addressable nucleobase geometry that can be precisely defined; and it is massively scalable into branched networks. Until now, the drawback of DNA as a conducting nanowire been, simply put, its low conductance. To address this deficiency, we extensively characterize a chemical variant of canonical DNA that exploits the affinity of natural cytosine bases for silver ions. We successfully construct chains of single silver ions inside double-stranded DNA, confirm the basic dC-Ag+-dC bond geometry and kinetics, and show length-tunability dependent on mismatch distribution, ion availability and enzyme activity. An analysis of the absorbance spectra of natural DNA and silver-binding, poly-cytosine DNA demonstrates the heightened thermostability of the ion chain and its resistance to aqueous stresses such as precipitation, dialysis and forced reduction. These chemically critical traits lend themselves to an increase in electrical conductivity of over an order of magnitude for 11-base silver-paired duplexes over natural strands when assayed by STM break junction. We further construct and implement a genetic pathway in the E. coli bacterium for the biosynthesis of highly ionizable DNA sequences. Toward future circuits, we construct a model of transcription network architectures to determine the most efficient and robust connectivity for cell-based fabrication, and we perform sequence optimization with a genetic algorithm to identify oligonucleotides robust to changes in the base-pairing energy landscape. We propose that this system will serve as a synthetic biological fabrication platform for more complex DNA nanotechnology and nanoelectronics with applications to deep space and low resource environments.

DNA↗