Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SHUNT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Deployment mechanisms on Pioneer Venus probes

Deployment mechanisms were developed to position scientific instruments during probe descent into the Venus atmosphere. Each mechanism includes a provision for pyrotechnic release of the enclosure door, negator springs for positive deployment torque, and an active damper using a shunted dc motor. The deployment time requirement is under 2 seconds, and the deployment shock must be less than 100 g's. The mechanism is completely dry lubricated and constructed mainly of titanium for high strength and high temperature stability. The mechanism was qualified for descent decelerations up to 565 g's and for instrument alignment up to 940 F. The mechanism requirements, the hardware design details, the analytical simulations, and the qualification testing are described.

Townsend, W. L.↗

Silicon-on-ceramic Process: Silicon Sheet Growth and Device Development for the Large-area Silicon Sheet and Cell Development Tasks of the Low-cost Solar Array Project

Significant progress is reported in fabricating a 4 sq cm cell having a 10.1 percent conversion efficiency and a 10 sq cm cell having a 9.2 percent conversion efficiency. The continuous (SCIM) coater succeeded in producing a 16 sq cm coating exhibiting unidirectional solidification and large grain size. A layer was grown at 0.2 cm/sec in the experimental coater which was partially dendritic but also contained a large smooth area approximately 100 micron m thick. The dark characteristic measurements of a typical SCC solar cell yield shunt resistance values of 10K ohms and series resistance values and 0.4 ohm. The production dip-coater is operating at over 50 percent yield in terms of good cell quality material. The most recent run yielded 13 good substrates out of 15.

Chapman, P. W.↗

Investigation of reliability attributes and accelerated stress factors on terrestrial solar cells

The results of accelerated stress testing of four different types of silicon terrestrial solar cells are discussed. The accelerated stress tests used included bias-temperature tests, bias-temperature-humidity tests, thermal cycle and thermal shock tests, and power cycle tests. Characterization of the cells was performed before stress testing and at periodic down-times, using electrical measurement, visual inspection, and metal adherence pull tests. Electrical parameters measured included short-circuit current, open circuit voltage, and output power, voltage, and current at the maximum power point. Incorporated in the report are the distributions of the prestress electrical data for all cell types. Data were also obtained on cell series and shunt resistance.

Prince, J. L.↗

The feasibility of inflight measurement of lightning strike parameters

The appearance of nonmetallic structural materials and microelectronics in aircraft design has resulted in a need for better knowledge of hazardous environments such as lightning and the effects these environments have on the aircraft. This feasibility study was performed to determine the lightning parameters in the greatest need of clarification and the performance requirements of equipment necessary to sense and record these parameters on an instrumented flight research aircraft. It was found that electric field rate of change, lightning currents, and induced voltages in aircraft wiring are the parameters of greatest importance. Flat-plate electric field sensors and resistive current shunts are proposed for electric field and current sensors, to provide direct measurements of these parameters. Six bit analog-to-digital signal conversion at a 5 nanosecond sampling rate, short-term storage of 85000 bits and long term storage of 5 x 10 to the 7th power bits of electric field, current and induced voltage data on the airplane are proposed, with readout and further analysis to be accomplished on the ground. A NASA F-106B was found to be suitable for use as the research aircraft because it has a minimum number of possible lightning attachment points, space for the necessary instrumentation, and appears to meet operational requirements. Safety considerations are also presented.

Crouch, K. E.↗

Force and impulse measurement

Practices are outlined for the design, installation, checkout, calibration, and operation of a thrust measurement system to be used during tests of a liquid monopropellant rocket engine. Appendixes include: (1) thrust measurement system elemental uncertainties; (2) short- and long-term thrust measurement system uncertainty; and (3) shunt calibration of force transducers.

Source record↗

Pressure measurement

Practices are outlined for the design, installation, checkout, calibration, and operation of a pressure measuring system to be used during tests of a liquid monopropellant rocket engine. Appendixes include: (1) pressure measurement system elemental uncertainties; (2) short- and long-term pressure measurement system uncertainty; (3) shunt calibration of pressure transducers; (4) special considerations for vacuum measurement; and (5) methods of determining the dynamic characteristics of pressure transducers. Design guidelines are provided for the critical components of each portion of the system to provide a pressure measurement system which meets the performance criteria specified.

Source record↗

Some failure modes and analysis techniques for terrestrial solar cell modules

Analysis data are presented on failed/defective silicon solar cell modules of various types and produced by different manufacturers. The failure mode (e.g., internal short and open circuits, output power degradation, isolation resistance degradation, etc.) are discussed in detail and in many cases related to the type of technology used in the manufacture of the modules; wherever applicable, appropriate corrective actions are recommended. Consideration is also given to some failure analysis techniques that are applicable to such modules, including X-ray radiography, capacitance measurement, cell shunt resistance measurement by the shadowing technique, steady-state illumination test station for module performance illumination, laser scanning techniques, and the SEM.

Shumka, A.↗

Self-reconfiguring solar cell system

A self-reconfiguring solar cell array is disclosed wherein some of the cells are switched so that they can be either in series or in shunt within the array. This feature of series or parallel switching of cells allows the array to match the load to achieve maximum power transfer. Automatic control is used to determine the conditions for maximum power operation and to switch the array into the appropriate configuration necessary to transfer maximum power to the load.

Gruber, R. P.↗

Development of improved wraparound contacts for silicon

A developmental process for fabricating 2 X 4 cm back surface field silicon solar cells featuring wraparound contacts and screen printed dielectric isolation is described. The process was then used to fabricate a number of cells for evaluation and study, as well as to establish the validity of the process sequence. While a number of cells exhibiting relatively good conversion efficiencies were produced, nearly all had low I-V curve factors for the level of efficiencies attained. Cells with conversion efficiencies of more than 15 percent (air mass zero and 25 C) had fill factors of only 0.76. Evidence as to the cause of this has not been conclusive, but is most probably linked to isolation failure in the wraparound dielectric and associated shunting problems.

Thornhill, J. W.↗

Lithium battery discharge tests

The long term discharge of a variety of lithium cells was characterized and the susceptibility of the cells to chemical variation during the slow discharge was tested. A shunt resistor was set across the terminals to monitor the voltage as a function of time. Failures were identified by premature voltage drops.

Johnson, C. J.↗

Steady-state analysis of a faulted three-phase four-wire system supplying induction motors with neutrals connected and other single-phase line-to-neutral loads

Four wire Wye connected ac power systems exhibit peculiar steady state fault characteristics when the fourth wire of three phase induction motors is connected. The loss of one phase of power source due to a series or shunt fault results in currents higher than anticipated on the remaining two phases. A theoretical approach to compute the fault currents and voltages is developed. A FORTRAN program is included in the appendix.

Wood, M. E.↗

Harmonics of 60 Hz in power systems caused by geomagnetic disturbances

Simultaneous VLF/ULF observations carried out near Winnipeg, Manitoba show that geomagnetic disturbances control the behavior of harmonics of 60 Hz man-made electric power. The harmonics of 60 Hz detected by the VLF receiver are at multiples of 180 Hz, indicating that they originated from a 3 phase ac power system. Under geomagnetically quiet conditions, only odd harmonics of 70 Hz were detected. In disturbed conditions, both odd and even harmonics were excited. The strength of each harmonic changed concurrently with geomagnetic pulsation (ULF) activity. These findings seem to indicate that a portion of telluric currents shunted into the power line system through the neutrals of the Y-connected transformers give rise to a dc bias to the transformer core materials and that it distorts their hysteresis loops, activating harmonics of 60 Hz power. A mathematical proof is given that a hysteresis loop having a point of symmetry generates odd harmonics only, whereas loops lacking in point-symmetry generally give rise to both odd and even harmonics. A general formula was obtained to calculate the strength of each harmonic based on the shape of the hysteresis loop.

Hayashi, K.↗

Induced electric currents in the Alaska oil pipeline measured by gradient, fluxgate, and SQUID magnetometers

The field gradient method for observing the electric currents in the Alaska pipeline provided consistent values for both the fluxgate and SQUID method of observation. These currents were linearly related to the regularly measured electric and magnetic field changes. Determinations of pipeline current were consistent with values obtained by a direct connection, current shunt technique at a pipeline site about 9.6 km away. The gradient method has the distinct advantage of portability and buried- pipe capability. Field gradients due to the pipe magnetization, geological features, or ionospheric source currents do not seem to contribute a measurable error to such pipe current determination. The SQUID gradiometer is inherently sensitive enough to detect very small currents in a linear conductor at 10 meters, or conversely, to detect small currents of one amphere or more at relatively great distances. It is fairly straightforward to achieve imbalance less than one part in ten thousand, and with extreme care, one part in one million or better.

Campbell, W. H.↗

Gallium arsenide (GaAs) solar cell modeling studies

Various models were constructed which will allow for the variation of system components. Computer studies were then performed using the models constructed in order to study the effects of various system changes. In particular, GaAs and Si flat plate solar power arrays were studied and compared. Series and shunt resistance models were constructed. Models for the chemical kinetics of the annealing process were prepared. For all models constructed, various parametric studies were performed.

Heinbockel, J. H.↗

Meniere's disease: A surgeon's tactics

Surgical procedures for treating Meniere's disease are discussed. Based on the results of 250 operations, it is concluded that interventions are sufficiently effective not only with vestibular dysfunction, but also with hearing disorders. In surgical treatment of Meniere's disease, it is expedient to adhere to by-stage tactics: to start with the simplest and least traumatic interventions - operations on the nerves of the tympanic cavity, and if these are ineffective to use more complex methods, including drainage or shunting of the endolymphatic sac.

Soldatov, I.↗

High-frequency measurements of multilayer ceramic capacitors

A resonant coaxial transmission line, short circuited at one end and open circuited at the other, whose fundamental resonant frequency and Q factor are known, is perturbed with a test capacitor connected either in series at the shorted end of the line, or in shunt at the open end. Measuring the Q factor of the system with the delta f technique yields the effective series resistance, capacitance, and the Q factor of the test specimen. This method of measurement has the advantage that there are no adjustable elements to alter circuit conditions in an unprescribed way, the only variable is the frequency which can be measured with an uncertainty of less than 1 ppm, the loss of the line as a function of frequency is quite predictable, and the Q factor of the line can be made sufficiently high to support accurate measurements of low loss capacitors.

Lafferty, R. E.↗

Advanced electric propulsion system concept for electric vehicles. Addendum 1: Voltage considerations

The two electric vehicle propulsion systems that best met cost and performance goals were examined to assess the effect of battery pack voltage on system performance and cost. A voltage range of 54 to 540 V was considered for a typical battery pack capacity of 24 k W-hr. The highest battery specific energy (W-hr/kg) and the lowest cost ($/kW-hr) were obtained at the minimum voltage level. The flywheel system traction motor is a dc, mechanically commutated with shunt field control, and due to the flywheel the traction motor and the battery are not subject to extreme peaks of power demand. The basic system uses a permanent-magnet motor with electronic commutation supplied by an ac power control unit. In both systems battery cost were the major factor in system voltage selection, and a battery pack with the minimum voltage of 54 V produced the lowest life-cycle cost. The minimum life-cycle cost for the basic system with lead-acid batteries was $0.057/km and for the flywheel system was $0.037/km.

Raynard, A. E.↗