Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reproducibility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

SU-E-T-118: Analysis of Variability and Stability Between Two Water Tank Phantoms Utilizing Water Tank Commissioning Procedures

Purpose: The commissioning criteria of water tank phantoms are essential for proper accuracy and reproducibility in a clinical setting. This study outlines the results of mechanical and dosimetric testing between PTW MP3-M water tank system and the Standard Imaging Doseview 3D water tank system. Methods: Measurements were taken of each axis of movement on the tank using 30 cm calipers at 1, 5, 10, 50, 100, and 200 mm for accuracy and reproducibility of tank movement. Dosimetric quantities such as percent depth dose and dose profiles were compared between tanks using a 6 MV beam from a Varian 23EX LINAC. Properties such as scanning speed effects, central axis depth dose agreement with static measurements, reproducibility of measurements, symmetry and flatness, and scan time between tanks were also investigated. Results: Results showed high geometric accuracy within 0.2 mm. Central axis PDD and in-field profiles agreed within 0.75% between the tanks. These outcomes test many possible discrepancies in dose measurements across the two tanks and form a basis for comparison on a broader range of tanks in the future. Conclusion: Both 3D water scanning phantoms possess a high degree of spatial accuracy, allowing for equivalence in measurements regardless of the phantom used. A commissioning procedure when changing water tanks or upon receipt of a new tank is nevertheless critical to ensure consistent operation before and after the arrival of new hardware.

60 APPLIED LIFE SCIENCES↗

SU-E-T-571: Newly Emerging Integrated Transmission Detector Systems Provide Online Quality Assurance of External Beam Radiation Therapy

Purpose: Two newly emerging transmission detectors positioned upstream from the patient have been evaluated for online quality assurance of external beam radiotherapy. The prototype for the Integral Quality Monitor (IQM), developed by iRT Systems GmbH (Koblenz, Germany) is a large-area ion chamber mounted on the linac accessory tray to monitor photon fluence, energy, beam shape, and gantry position during treatment. The ion chamber utilizes a thickness gradient which records variable response dependent on beam position. The prototype of Delta4 Discover™, developed by ScandiDos (Uppsala, Sweden) is a linac accessory tray mounted 4040 diode array that measures photon fluence during patient treatment. Both systems are employable for patient specific QA prior to treatment delivery. Methods: Our institution evaluated the reproducibility of measurements using various beam types, including VMAT treatment plans with both the IQM ion chamber and the Delta4 Discover diode array. Additionally, the IQM’s effect on photon fluence, dose response, simulated beam error detection, and the accuracy of the integrated barometer, thermometer, and inclinometer were characterized. The evaluated photon beam errors are based on the annual tolerances specified in AAPM TG-142. Results: Repeated VMAT treatments were measured with 0.16% reproducibility by the IQM and 0.55% reproducibility by the Delta4 Discover. The IQM attenuated 6, 10, and 15 MV photon beams by 5.43±0.02%, 4.60±0.02%, and 4.21±0.03% respectively. Photon beam profiles were affected <1.5% in the non-penumbra regions. The IQM’s ion chamber’s dose response was linear and the thermometer, barometer, and inclinometer agreed with other calibrated devices. The device detected variations in monitor units delivered (1%), field position (3mm), single MLC leaf positions (13mm), and photon energy. Conclusion: We have characterized two new transmissions detector systems designed to provide in-vivo like measurements upstream from the patient. Both systems demonstrate substantial utility for online treatment verification and QA of photon external beam radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-775: Use of Electronic Portal Imaging Device (EPID) for Quality Assurance (QA) of Electron Beams On Varian Truebeam System

Purpose: In a previous study we have demonstrated the feasibility of using EPID to QA electron beam parameters on a single Varian TrueBeam LINAC. This study aims to provide further investigation on (1) reproducibility of using EPID to detect electron beam energy changes on multiple machines and (2) evaluation of appropriate calibration methods to compare results from different EPIDs. Methods: Ad-hoc mode electron beam images were acquired in developer mode with XML code. Electron beam data were collected on a total of six machines from four institutions. A custom-designed double-wedge phantom was placed on the EPID detector. Two calibration methods - Pixel Sensitivity Map (PSM) and Large Source-to-Imager Distance Flood Field (LSID-FF) - were used. To test the sensitivity of EPID in detecting energy drifts, Bending Magnet Current (BMC) was detuned to invoke energy changes corresponding to ∼±1.5 mm change in R50% of PDD on two machines from two institutions. Percent depth ionization (PDI) curves were then analyzed and compared with the respective baseline images using LSID-FF calibration. For reproducibility testing, open field EPID images and images with a standard testing phantom were collected on multiple machines. Images with and without PSM correction for same energies on different machines were overlaid and compared. Results: Two pixel shifts were observed in PDI curve when energy changes exceeded the TG142 tolerance. PSM showed the potential to correct the differences in pixel response of different imagers. With PSM correction, the histogram of images differences obtained from different machines showed narrower distributions than those images without PSM correction. Conclusion: EPID is sensitive for electron energy changes and the results are reproducible on different machines. When overlaying images from different machines, PSM showed the ability to partially eliminate the intrinsic variation of various imagers. Research Funding from Varian Medical Systems Inc.Dr. Sasa Mutic receives compensation for providing patient safety training services from Varian Medical Systems, the sponsor of this study.

60 APPLIED LIFE SCIENCES↗

Development of a video image-based QA system for the positional accuracy of dynamic tumor tracking irradiation in the Vero4DRT system

Purpose: To develop and evaluate a new video image-based QA system, including in-house software, that can display a tracking state visually and quantify the positional accuracy of dynamic tumor tracking irradiation in the Vero4DRT system. Methods: Sixteen trajectories in six patients with pulmonary cancer were obtained with the ExacTrac in the Vero4DRT system. Motion data in the cranio–caudal direction (Y direction) were used as the input for a programmable motion table (Quasar). A target phantom was placed on the motion table, which was placed on the 2D ionization chamber array (MatriXX). Then, the 4D modeling procedure was performed on the target phantom during a reproduction of the patient’s tumor motion. A substitute target with the patient’s tumor motion was irradiated with 6-MV x-rays under the surrogate infrared system. The 2D dose images obtained from the MatriXX (33 frames/s; 40 s) were exported to in-house video-image analyzing software. The absolute differences in the Y direction between the center of the exposed target and the center of the exposed field were calculated. Positional errors were observed. The authors’ QA results were compared to 4D modeling function errors and gimbal motion errors obtained from log analyses in the ExacTrac to verify the accuracy of their QA system. The patients’ tumor motions were evaluated in the wave forms, and the peak-to-peak distances were also measured to verify their reproducibility. Results: Thirteen of sixteen trajectories (81.3%) were successfully reproduced with Quasar. The peak-to-peak distances ranged from 2.7 to 29.0 mm. Three trajectories (18.7%) were not successfully reproduced due to the limited motions of the Quasar. Thus, 13 of 16 trajectories were summarized. The mean number of video images used for analysis was 1156. The positional errors (absolute mean difference + 2 standard deviation) ranged from 0.54 to 1.55 mm. The error values differed by less than 1 mm from 4D modeling function errors and gimbal motion errors in the ExacTrac log analyses (n = 13). Conclusions: The newly developed video image-based QA system, including in-house software, can analyze more than a thousand images (33 frames/s). Positional errors are approximately equivalent to those in ExacTrac log analyses. This system is useful for the visual illustration of the progress of the tracking state and for the quantification of positional accuracy during dynamic tumor tracking irradiation in the Vero4DRT system.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP4-04: Commissioning and Acceptance Testing of Optical Surface Monitoring System On TrueBEAM STx as Per Task Group 147

Purpose: Optical Surface Monitoring system (OSMS) have been recently introduced by Varian for initial patient positioning and real-time monitoring during complex radiotherapy treatment. The purpose of this work was to implement TG 147 with OSMS. Methods: Recently we installed OSMS first of its kind in India on trueBEAM STx at our Institue. The OSMS is composed of a three cameras ceiling mounted and a Workstation. The following tests were performed to validate the system a. Calibration b. System reproducibility and drift c. Static localization displacement accuracy and d. Dynamic radiation gating delivery. The Calibration procedure consists of Daily,Monthly and MV Radiation Isocenter Calibration. The reproducibility of system was tested by monitoring the varian gating phantom test pattern for at least 120 min. Each recorded pattern was registered to the reference surface to calculate the required couch adjustment. To measure the static localization displacement accuracy of the system to detect and quantify patient shift relative to a reference image,we compared the shift detected by the surface imaging system with known couch transitions in a phantom study. The phantom was set in a motion and the radiation beam was holded by changing the threshold in the software for different clinical setups to test the dynamic radiation gating capability. Results: Daily calibration was within ±0.5 mm. The MV radiation isocentre with respect to cameras was less than 1 mm in translational axis and less than 0.5° for rotational axis. The reproducibility was found to be 0.4 mm. The maximum static displacement accuracy was 0.75 mm for the three translational axis, and less than 0.5° for rotational axis. The system was able to hold the beam with a minimum threshold of 1 mm. Conclusion: A quality assurance process has been developed as per TG 147 for the clinical implementation of an OSMS in radiation therapy.

60 APPLIED LIFE SCIENCES↗

TU-AB-BRA-07: Distortion-Free 3D Diffusion MRI On An MRI-Guided Radiotherapy System for Longitudinal Tumor Response Assessment

Purpose: To develop a reliable, 3D distortion-free diffusion MRI technique for longitudinal tumor response assessment and MRI-guided adaptive radiotherapy(RT). Methods: A diffusion prepared 3D turbo spin echo readout (DP-TSE) sequence was developed and compared with the conventional diffusion-weighted single-shot echo-planar-imaging (DW-ssEPI) sequence in a commercially available diffusion phantom, and one head-and-neck and one brain cancer patient on an MRI-guided RT system (ViewRay). In phantom study, the geometric fidelity was quantified as the ratio between the left-right (RL) and anterior-posterior (AP) dimension. Ten slices were measured on DP-TSE, DW-ssEPI and standard TSE images where the later was used as the geometric reference. ADC accuracy was verified at both 0°C (reference ADC available) and room temperature with a range of diffusivity between 0.35 and 2.0*10{sup −3}mm{sup 2}/s. The ADC reproducibility was assessed based on 8 room-temperature measurements on 6 different days. In the pilot single-slice in-vivo study, CT images were used as the geometric reference, and ADC maps from both diffusion sequences were compared. Results: Distortion and susceptive-related artifact were severe in DW-ssEPI, with significantly lower RL/AP ratio (0.9579±0.0163) than DP-TSE (0.9990±0.0031) and TSE (0.9995±0.0031). ADCs from the two diffusion sequences both matched well with the vendor-provided values at 0°C; however DW-ssEPI fails to provide accurate ADC for high diffusivity vials at room temperature due to high noise level (10 times higher than DP-TSE). The DP-TSE sequence had excellent ADC reproducibility with <4% ADC variation among 8 separate measurements. In patient study, DP-TSE exhibited substantially improved geometric reliability. ROI analysis in ADC maps generated from DP-TSE and DW-ssEPI showed <5% difference where high b-value images were excluded from the latter approach due to excessive noise level. Conclusion: A diffusion MRI sequence with excellent geometric fidelity, accurate and highly reproducible ADC measurements was proposed for longitudinal tumor response assessment using an MRI-guided RT system. Yu Gao acknowledges research support from ViewRay.

60 APPLIED LIFE SCIENCES↗

Noise suppressed partial volume correction for cardiac SPECT/CT

Purpose: Partial volume correction (PVC) methods typically improve quantification at the expense of increased image noise and reduced reproducibility. In this study, the authors developed a novel voxel-based PVC method that incorporates anatomical knowledge to improve quantification while suppressing noise for cardiac SPECT/CT imaging. Methods: In the proposed method, the SPECT images were first reconstructed using anatomical-based maximum a posteriori (AMAP) with Bowsher’s prior to penalize noise while preserving boundaries. A sequential voxel-by-voxel PVC approach (Yang’s method) was then applied on the AMAP reconstruction using a template response. This template response was obtained by forward projecting a template derived from a contrast-enhanced CT image, and then reconstructed using AMAP to model the partial volume effects (PVEs) introduced by both the system resolution and the smoothing applied during reconstruction. To evaluate the proposed noise suppressed PVC (NS-PVC), the authors first simulated two types of cardiac SPECT studies: a {sup 99m}Tc-tetrofosmin myocardial perfusion scan and a {sup 99m}Tc-labeled red blood cell (RBC) scan on a dedicated cardiac multiple pinhole SPECT/CT at both high and low count levels. The authors then applied the proposed method on a canine equilibrium blood pool study following injection with {sup 99m}Tc-RBCs at different count levels by rebinning the list-mode data into shorter acquisitions. The proposed method was compared to MLEM reconstruction without PVC, two conventional PVC methods, including Yang’s method and multitarget correction (MTC) applied on the MLEM reconstruction, and AMAP reconstruction without PVC. Results: The results showed that the Yang’s method improved quantification, however, yielded increased noise and reduced reproducibility in the regions with higher activity. MTC corrected for PVE on high count data with amplified noise, although yielded the worst performance among all the methods tested on low-count data. AMAP effectively suppressed noise and reduced the spill-in effect in the low activity regions. However it was unable to reduce the spill-out effect in high activity regions. NS-PVC yielded superior performance in terms of both quantitative assessment and visual image quality while improving reproducibility. Conclusions: The results suggest that NS-PVC may be a promising PVC algorithm for application in low-dose protocols, and in gated and dynamic cardiac studies with low counts.

60 APPLIED LIFE SCIENCES↗

Successional trajectories of rhizosphere bacterial communities over consecutive seasons

It is well known that rhizosphere microbiomes differ from those of surrounding soil, and yet we know little about how these root-associated microbial communities change through the growing season and between seasons. We analyzed the response of soil bacteria to roots of the common annual grass Avena fatua over two growing seasons using high-throughput sequencing of 16S rRNA genes. Over the two periods of growth, the rhizosphere bacterial communities followed consistent successional patterns as plants grew, although the starting communities were distinct. Succession in the rhizosphere was characterized by a significant decrease in both taxonomic and phylogenetic diversity relative to background soil communities, driven by reductions in both richness and evenness of the bacterial communities. Plant roots selectively stimulated the relative abundance of Alphaproteobacteria , Betaproteobacteria , and Bacteroidetes but reduced the abundance of Acidobacteria , Actinobacteria , and Firmicutes . Taxa that increased in relative abundance in the rhizosphere soil displayed phylogenetic clustering, suggesting some conservation and an evolutionary basis for the response of complex soil bacterial communities to the presence of plant roots. The reproducibility of rhizosphere succession and the apparent phylogenetic conservation of rhizosphere competence traits suggest adaptation of the indigenous bacterial community to this common grass over the many decades of its presence. We document the successional patterns of rhizosphere bacterial communities associated with a “wild” annual grass, Avena fatua , which is commonly a dominant plant in Mediterranean-type annual grasslands around the world; the plant was grown in its grassland soil. Most studies documenting rhizosphere microbiomes address “domesticated” plants growing in soils to which they are introduced. Rhizosphere bacterial communities exhibited a pattern of temporal succession that was consistent and repeatable over two growing seasons. There are few studies assessing the reproducibility over multiple seasons. Through the growing season, the rhizosphere community became progressively less diverse, likely reflecting root homogenization of soil microniches. Phylogenetic clustering of the rhizosphere dynamic taxa suggests evolutionary adaptation to Avena roots. The reproducibility of rhizosphere succession and the apparent phylogenetic conservation of rhizosphere competence traits suggest adaptation of the indigenous bacterial community to this common grass over the many decades of its presence.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Calculation of Young’s Modulus of MoS{sub 2}-Based Single-Wall Nanotubes Using Force-Field and Hybrid Density Functional Theory

A force field is proposed that reproduces with a high accuracy a large number of properties of the bulk crystal MoS{sub 2} phases, monolayers, and nanotubes. The reproduced values are both the experimental results and the results of quantum chemical calculations. The elaborated interaction potential can be useful primarily for investigation of multiwall MoS{sub 2} nanotubes and their thermodynamic properties, especially, since the potential is able to reproduce the frequencies of the crystal phonon spectrum. In this study the proposed potential is applied to simulate the temperature dependence of a number of properties of the armchair and zigzag nanotubes. The calculations have been performed using molecular mechanics method within the framework of quasi harmonic approximation which is carried out through the estimation of the temperature dependence of the Helmholtz free energy.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Measurement of deuteron spectra and elliptic flow in Pb–Pb collisions at $\sqrt{s_{\mathrm {NN}}}$ = 2.76 TeV at the LHC

The transverse momentum (p T ) spectra and elliptic flow coefficient (v 2 ) of deuterons and anti-deuterons at mid-rapidity (|y|<0.5) are measured with the ALICE detector at the LHC in Pb–Pb collisions at $\sqrt{s}$ NN = 2.76 TeV. The measurement of the p T spectra of (anti-)deuterons is done up to 8 GeV/c in 0–10% centrality class and up to 6 GeV/c in 10–20% and 20–40% centrality classes. The v 2 is measured in the 0.8 < p T < 5 GeV/c interval and in six different centrality intervals (0–5, 5–10, 10–20, 20–30, 30–40 and 40–50%) using the scalar product technique. Measured π ± , K ± and p+$\bar{p}$ transverse-momentum spectra and v 2 are used to predict the deuteron p T spectra and v 2 within the Blast-Wave model. The predictions are able to reproduce the v 2 coefficient in the measured p T range and the transverse-momentum spectra for p T > 1.8 GeV/c within the experimental uncertainties. The measurement of the coalescence parameter B 2 is performed, showing a p T dependence in contrast with the simplest coalescence model, which fails to reproduce also the measured v 2 coefficient. Finally, in addition, the coalescence parameter B 2 and the elliptic flow coefficient in the 20–40% centrality interval are compared with the AMPT model which is able, in its version without string melting, to reproduce the measured v 2 (p T ) and the B 2 (p T ) trend.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Light $$Z^\prime $$ and Dirac fermion dark matter in the $$B-L$$ model

Abstract We consider a $$U(1)_{B-L}$$ U ( 1 ) B - L model with a $$Z^\prime $$ Z ′ portal Dirac fermion dark matter (DM) $$\chi $$ χ of low mass which couples very weakly to the $$B - L$$ B - L gauge boson $$Z^\prime $$ Z ′ . An arbitrary $$B-L$$ B - L charge $$Q\ne \pm 1, \pm 3$$ Q ≠ ± 1 , ± 3 of the DM $$\chi $$ χ ensures its stability. Motivated by the sensitivity reach of forthcoming “Lifetime Frontier” experiments, we focus on the $$Z^\prime $$ Z ′ mass, $$m_{Z^\prime }$$ m Z ′ , in the sub-GeV to few GeV range. To evaluate the DM relic abundance, we examine both the freeze-out and freeze-in DM scenarios. For the freeze-out scenario, we show that the observed DM abundance is reproduced near the $$Z^\prime $$ Z ′ resonance, $$m_\chi \simeq m_{Z^\prime }/2$$ m χ ≃ m Z ′ / 2 , where $$m_\chi $$ m χ is the DM mass. For the freeze-in scenario, we focus on $$m_\chi \ll m_{Z^\prime }$$ m χ ≪ m Z ′ . We show that for a fixed value of $$m_{Z^\prime }$$ m Z ′ , $$g_{BL}$$ g BL values roughly scale as 1/ Q to reproduce the observed DM abundance. For various Q values in the range between $$10^{-6}$$ 10 - 6 and $$10^2$$ 10 2 , we show that the gauge coupling values $$g_{BL}$$ g BL needed to reproduce the observed DM abundance lie in the search reach of future planned and/or proposed experiments such as FASER, Belle-II, LDMX, and SHiP. In the freeze-in case, the Q values to realize observable $$g_{BL}$$ g BL values are found to be much smaller than that in the freeze-out case.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Explicit solvent machine-learned coarse-grained model of sodium polystyrene sulfonate to capture polymer structure and dynamics

In this article, strongly charged polyelectrolytes (PEs) demonstrate complex solution behavior as a function of chain length, concentrations, and ionic strength. The viscosity behavior is important to understand and is a core quantity for many applications, but aspects remain a challenge. Molecular dynamics simulations using implicit solvent coarse-grained (CG) models successfully reproduce structure, but are often inappropriate for calculating viscosities. To address the need for CG models which reproduce viscoelastic properties of one of the most studied PEs, sodium polystyrene sulfonate (NaPSS), we report our recent efforts in using Bayesian optimization to develop CG models of NaPSS which capture both polymer structure and dynamics in aqueous solutions with explicit solvent. We demonstrate that our explicit solvent CG NaPSS model with the ML-BOP water model [Chan et al. Nat Commun 10, 379 (2019)] quantitatively reproduces NaPSS chain statistics and solution structure. The new explicit solvent CG model is benchmarked against diffusivities from atomistic simulations and experimental specific viscosities for short chains. We also show that our Bayesian-optimized CG model is transferable to larger chain lengths across a range of concentrations. Overall, this work provides a machine-learned model to probe the structural, dynamic, and rheological properties of polyelectrolytes such as NaPSS and aids in the design of novel, strongly charged polymers with tunable structural and viscoelastic properties

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Membrane Pretreatment and Cell Conditioning for Proton Exchange Membrane Water Electrolysis

As the research community studying proton exchange membrane water electrolysis (PEMWE) grows, it is important to develop methods that achieve transparent, reproducible research. Reproducibility of performance and durability is a challenge facing the PEMWE field, as the published literature includes a wide spread of results obtained with nominally similar materials. Prior round-robin performance benchmarking efforts [1] have identified inadequate cell conditioning as a major source of variation in apparent cell performance. Inadequate pre-treatment and conditioning can lead to instability in initial performance and adds ambiguity to durability measurements. However, excessively prolonged conditioning procedures limit the throughput of testing and the pace of research. Pretreatment and conditioning methods vary significantly across the research literature, but little systematic investigation is available into the mechanisms of these procedures or how procedural differences may impact results. This presentation will discuss investigations into the effects of membrane pre-treatment and operating procedures during cell conditioning on initial performance and catalyst-specific accelerated stress tests, with the aim of recommending procedures to enable clear, reproducible, and high-throughput research. Methods investigated include the use of hydrogen peroxide, acids, and hydration at elevated temperature for membrane pretreatment, and conditioning procedures such as current or voltage holds and cycling. The investigations cover both the impacts of these procedures on cell performance and stability as well as underlying mechanisms and processes taking place in the cell materials.

cell↗

Clouds, Aerosols, and Precipitation in the Marine Boundary Layer: An Arm Mobile Facility Deployment

The Clouds, Aerosol, and Precipitation in the Marine Boundary Layer (CAP-MBL) deployment at Graciosa Island in the Azores generated a 21 month (April 2009-December 2010) comprehensive dataset documenting clouds, aerosols and precipitation using the Atmospheric Radiation Measurement (ARM) Mobile Facility (AMF). The scientific aim of the deployment is to gain improved understanding of the interactions of clouds, aerosols and precipitation in the marine boundary layer. Graciosa Island straddles the boundary between the subtropics and midlatitudes in the Northeast Atlantic Ocean, and consequently experiences a great diversity of meteorological and cloudiness conditions. Low clouds are the dominant cloud type, with stratocumulus and cumulus occurring regularly. Approximately half of all clouds contained precipitation detectable as radar echoes below the cloud base. Radar and satellite observations show that clouds with tops from 1- 11 km contribute more or less equally to surface-measured precipitation at Graciosa. A wide range of aerosol conditions was sampled during the deployment consistent with the diversity of sources as indicated by back trajectory analysis. Preliminary findings suggest important two-way interactions between aerosols and clouds at Graciosa, with aerosols affecting light precipitation and cloud radiative properties while being controlled in part by precipitation scavenging. The data from at Graciosa are being compared with short-range forecasts made a variety of models. A pilot analysis with two climate and two weather forecast models shows that they reproduce the observed time-varying vertical structure of lower-tropospheric cloud fairly well, but the cloud-nucleating aerosol concentrations less well. The Graciosa site has been chosen to be a permanent fixed ARM site that became operational in October 2013.

clouds↗

Understanding the Drivers of Atlantic Multidecadal Variability using a Stochastic Model Hierarchy

The relative importance of ocean and atmospheric dynamics in generating Atlantic Multidecadal Variability (AMV) remains an open question. Comparisons between climate models with SLAB and fully-dynamic (FULL) ocean components are often used to explore this question, but cannot reveal how individual ocean processes generate these differences. We build a hierarchy of physically interpretable stochastic models to investigate the contribution of two upper-ocean processes to AMV: the role of seasonal variation and mixed-layer entrainment. This interpretability arises from the stochastic model’s simplified representation of sea surface temperature (SST), considering only the local upper ocean response to white-noise atmospheric forcing and its impact on surface heat exchange. We focus on understanding differences between SLAB and FULL non-eddy resolving pre-industrial control simulations of the Community Earth System Model 1 (CESM), and estimate the stochastic model parameters from each respective simulation. Despite its simplicity, the stochastic model reproduces temporal characteristics of SST variability in the SPG, including reemergence, seasonal-to-interannual persistence and power spectra. Furthermore, unrealistically persistent SST of the CESM-SLAB ocean simulation is reproduced in the equivalent stochastic model configuration where the mixed-layer depth (MLD) is constant. The stochastic model also reveals that vertical entrainment primarily damps SST variability, thus explaining why SLAB exhibits larger SST variance than FULL. Here, the stochastic model driven by temporally stochastic, spatially coherent forcing patterns reproduces the canonical AMV pattern. However, the amplitude of low-frequency variability remains underestimated, suggesting a role for ocean dynamics beyond entrainment.

54 ENVIRONMENTAL SCIENCES↗

On the Realism of the Rain Microphysics Representation of a Squall Line in the WRF Model. Part I: Evaluation with Multifrequency Cloud Radar Doppler Spectra Observations

This study investigates how multifrequency cloud radar observations can be used to evaluate the representation of rain microphysics in the WRF Model using two bulk microphysics schemes. A squall line observed over Oklahoma on 12 June 2011 is used as a case study. A recently developed retrieval technique combining observations of two vertically pointing cloud radars provides quantitative description of the drop size distribution (DSD) properties of the transition and stratiform regions of the squall-line system. For the first time, the results of this multifrequency cloud radar retrieval are compared to more conventional retrievals from a nearby polarimetric radar, and a supplementary result of this work is that this new methodology provides a much more detailed description of the DSD vertical and temporal variations. While the extent and evolution of the squall line is well reproduced by the model, the 1-h low-reflectivity transition region is not. In the stratiform region, simulations with both schemes are able to reproduce the observed downdraft and the associated significative subsaturation below the melting level, but with a slight overestimation of the relative humidity. Under this subsaturated air, the simulated rain mixing ratio continuously decreases toward the ground, in agreement with the observations. Conversely, the profiles of the mean volume diameter and the concentration parameter of the DSDs are not well reproduced. These discrepancies pinpoint at an issue in the representation of rain microphysics. The companion paper, investigates the sources of the biases in the microphysics processes in the rain layer by performing numerical sensitivity studies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A rapid assay for assessing bacterial effects on Arabidopsis thermotolerance

Abstract Background The role of beneficial microbes in mitigating plant abiotic stress has received considerable attention. However, the lack of a reproducible and relatively high-throughput screen for microbial contributions to plant thermotolerance has greatly limited progress in this area, this slows the discovery of novel beneficial isolates and the processes by which they operate. Results We designed a rapid phenotyping method to assess the effects of bacteria on plant host thermotolerance. After testing multiple growth conditions, a hydroponic system was selected and used to optimize an Arabidopsis heat shock regime and phenotypic evaluation. Arabidopsis seedlings germinated on a PTFE mesh disc were floated onto a 6-well plate containing liquid MS media, then subjected to heat shock at 45 °C for various duration. To characterize phenotype, plants were harvested after four days of recovery to measure chlorophyll content. The method was extended to include bacterial isolates and to quantify bacterial contributions to host plant thermotolerance. As an exemplar, the method was used to screen 25 strains of the plant growth promoting Variovorax spp. for enhanced plant thermotolerance. A follow-up study demonstrated the reproducibility of this assay and led to the discovery of a novel beneficial interaction. Conclusions This method enables rapid screening of individual bacterial strains for beneficial effects on host plant thermotolerance. The throughput and reproducibility of the system is ideal for testing many genetic variants of Arabidopsis and bacterial strains.

59 BASIC BIOLOGICAL SCIENCES↗

The Resource Identification Initiative: A cultural shift in publishing

A central tenet in support of research reproducibility is the ability to uniquely identify research resources, i.e., reagents, tools, and materials that are used to perform experiments. However, current reporting practices for research resources are insufficient to allow humans and algorithms to identify the exact resources that are reported or answer basic questions such as “What other studies used resource X?” To address this issue, the Resource Identification Initiative was launched as a pilot project to improve the reporting standards for research resources in the methods sections of papers and thereby improve identifiability and reproducibility. The pilot engaged over 25 biomedical journal editors from most major publishers, as well as scientists and funding officials. Authors were asked to include Research Resource Identifiers (RRIDs) in their manuscripts prior to publication for three resource types: antibodies, model organisms, and tools (including software and databases). RRIDs represent accession numbers assigned by an authoritative database, e.g., the model organism databases, for each type of resource. To make it easier for authors to obtain RRIDs, resources were aggregated from the appropriate databases and their RRIDs made available in a central web portal (www.scicrunch.org/resources). RRIDs meet three key criteria: they are machine readable, free to generate and access, and are consistent across publishers and journals. The pilot was launched in February of 2014 and over 300 papers have appeared that report RRIDs. The number of journals participating has expanded from the original 25 to more than 40. Here, we present an overview of the pilot project and its outcomes to date. We show that authors are generally accurate in performing the task of identifying resources and supportive of the goals of the project. We also show that identifiability of the resources pre- and post-pilot showed a dramatic improvement for all three resource types, suggesting that the project has had a significant impact on reproducibility relating to research resources.

59 BASIC BIOLOGICAL SCIENCES↗