Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reference Values”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Morphological predictors for lymph node metastases on computed tomography in colon cancer

Introduction/Background: The aim of the study was to assess morphological predictors for lymph node metastases (Stage III disease) in colon cancer on computed tomography. Methods and materials: Ninety-four patients with histology-proven colon cancer (adenocarcinoma) who underwent elective primary curative resection between the years 2012 and 2014 were included. Contrast-enhanced CT examinations were independently reviewed by two blinded observers regarding tumor location, depth of tumor invasion, and presence of lymph node metastases. Ocular presence of internal heterogeneity and presence of irregular outer border were used as morphological criteria for lymph node involvement. Protocol-based histopathology after curative surgery served as reference standard. Sensitivity, specificity, positive (PPV) and negative (NPV) predictive values, and accuracy for each morphological criterion for prediction of stage III disease were calculated. Inter-observer agreement was compared using Kappa statistics. Results: According to histopathology, 59 patients were staged as I–II disease and 35 patients were staged as stage III disease. The presence of internal heterogeneity in a lymph node on CT resulted in moderate sensitivity (66–77%) but high specificity (95–95%) for prediction of Stage III disease by both observers. The presence of irregular outer border also resulted in poor sensitivity (49–54%) but high specificity (97–97%). The combination of either internal heterogeneity and/or irregular outer border per patient resulted in a moderate sensitivity (67–77%) and high specificity (95–95%), PPV (89–96%), and NPV (84–88%). Inter-observer agreement (Cohens Kappa) was 0.72. Consensus reading for the combined criteria resulted in sensitivity and specificity of 69% and 100%, respectively. Conclusion: Using morphological criteria for lymph node metastases on CT examination in patients with colon cancer results in high specificity but moderate sensitivity in predicting stage III disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Insights into factors that affect non-Arrhenius migration of a simulated incoherent Σ3 grain boundary

Non-Arrhenius grain boundary migration, sometimes referred to as antithermal migration where temperature and GB velocity values are inversely related to each other, is examined in an incoherent twin Σ3 [111] 60° (11 8 5) nickel grain boundary. Molecular dynamics is used to simulate migration and examine the effect of various factors on the migration, including interatomic potential, system size, driving force, and variation of atomic grain boundary structure. A classical model for grain boundary migration, in its unsimplified form, is used to analyze the results. The grain boundaries exhibit migration mechanisms with very low apparent barrier heights to migration. As a result, the boundaries migrate quickly but exhibit a velocity saturation similar to that of dislocations. Furthermore, the various interatomic potentials exhibit different migration velocities, but their similarities suggest they all predict similar overall behaviors of migration. The variation of atomic structure in the same incoherent twin grain boundary leads to diverse behaviors with barrier heights that vary from non-Arrhenius to Arrhenius migration. Facet nucleation is confirmed not to be a requirement for this boundary based on an examination of simulation cell size; however, the presence and/or interaction between numerous facets does suggest a slowing and increased barrier height to migration for larger boundaries.

36 MATERIALS SCIENCE↗

Analyzing LF/VLF Lightning Waveforms to Estimate D-region Electron Density Profiles

Lightning waveforms in the low frequency (LF; 30-300 kHz) and the very low frequency (VLF; 3-30 kHz) bands can be exploited to produce data-driven ionospheric D-region electron density profile (EDP) estimates with significantly higher spatial and temporal coverage than previously available. The lightning waveforms used in this paper are signals detected in the LF/VLF of negative cloud-to-ground lightning by the Earth Networks Total Lightning Detection Network. Each waveform contains a ground wave and a time-delayed ionospheric reflection. The time delay between the ground wave and ionospheric reflection has previously been used to estimate a single specular reflection altitude, where LF/VLF emissions are reflected by the ionosphere. Here, we expand upon previous methods to include filtering and spectral analysis, and account for oblique propagation to produce higher-order estimates for reflection altitudes and corresponding electron densities. Once estimated, reflection altitudes and corresponding electron densities can be used to derive parameters β and h’, which define an EDP for the D-region. In this study, the lightning waveform (LW) analysis is demonstrated using a single representative 24-hour dataset over the Southeast United States, and then extended to a total of 10 separate datasets with varying locations and ionospheric conditions. The LW-derived D-region EDPs are in agreement with predictions made by the Faraday International Reference Ionosphere model, and the LW EDPs β and h’ values are consistent with previous LF/VLF-derived estimates.

D-region ionosphere↗

Energy dissipation in polymer-bonded explosives with various levels of constituent plasticity and internal friction

The ignition of energetic materials (EM) under dynamic loading is mainly controlled by localized temperature spikes known as hotspots. Hotspots occur due to several dissipation mechanisms, including viscoplasticity, viscoelasticity, and internal friction along crack surfaces. In this work, to analyze the contributions of these mechanisms, we quantify the ignition probability, energy dissipation, damage evolution, and hotspot characteristics of polymer-bonded explosives (PBXs) with various levels of constituent plasticity of the energetic phase and internal crack face friction. Using PBX9501 consisting of HMX (Octahydro-1,3,5,7-Tetranitro-1,2,3,5-Tetrazocine) and Estane as a reference material, we analyze variants of this material with several values of the yield stress of the energetic phase and coefficients of internal crack face friction, while other parameters are kept unchanged. The impact loading involves piston velocities between 200 and 1200 m/s. The analysis uses a Lagrangian cohesive finite element framework that explicitly accounts for finite-strain elastic-viscoplastic deformation of the grains, viscoelastic deformation of the binder, arbitrary crack initiation and propagation in the grains and the binder, debonding between the grains and the binder, contact between internal surfaces, friction and frictional heating along internal surfaces, heat generation resulting from inelastic bulk deformation, and heat conduction. To determine the ignition status of the material or “go” or “no-go” state, we use a criterion based on a criticality threshold obtained from chemical kinetics calculations. For PBX with various levels of HMX plasticity and friction, the probability of ignition, the evolution of dissipation caused by plasticity and friction, the density of cracks, and the locations of cracks are quantified. Results show that samples with higher levels of constituent plasticity (lower yield strengths) or lower levels of internal friction are less likely to ignite. The relative importance of plasticity and friction depends on load intensity, with frictional heating decreasing as load intensity increases. Although the overall viscoplastic heating outweighs the overall frictional heating, friction plays a very important role in hotspot development at all load intensities analyzed, owing to the fact that frictional heating is more localized than viscoplastic heating. Finally, the predicted thresholds and ignition probabilities are expressed in a load intensity-load duration relation for PBX with different constituent properties.

36 MATERIALS SCIENCE↗

First measurement of quarkonium polarization in nuclear collisions at the LHC

The polarization of inclusive J/ψ and Υ(1S) produced in Pb–Pb collisions at √ s NN = 5.02 TeV at the LHC is measured with the ALICE detector. The study is carried out by reconstructing the quarkonium through its decay to muon pairs in the rapidity region 2.5 < y < 4 and measuring the polar and azimuthal angular distributions of the muons. The polarization parameters λ θ , λ φ and λ θφ are measured in the helicity and Collins-Soper reference frames, in the transverse momentum interval 2 < p T < 10 GeV/c and p T < 15 GeV/c for the J/ψ and Υ(1S), respectively. The polarization parameters for the J/ψ are found to be compatible with zero, within a maximum of about two standard deviations at low p T , for both reference frames and over the whole p T range. The values are compared with the corresponding results obtained for pp collisions at √s = 7 and 8 TeV in a similar kinematic region by the ALICE and LHCb experiments. Although with much larger uncertainties, the polarization parameters for Υ(1S) production in Pb–Pb collisions are also consistent with zero

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A new tensile stage for in situ electron microscopy examination of the mechanical properties of 'superelastic' specimens

We have developed a novel tensile stage that can be used for in situ electron microscopy examination of the mechanical properties of ''superelastic'' materials. In our stage, one of the specimen clamps is replaced by a cylindrical roller, which when driven by a motor can easily stretch (''roll on'') any specimen irrespective of its plastic properties. We have used the so-called Roll-o-meter in the study of the tensile behavior of two different film formed latex formulations, here referred to as standard and novel. We find that the values of the tensile strength and extension to break of the studied systems, measured by using the Roll-o-meter, are similar to those measured by a Hounsfield tensile testing machine outside the microscope chamber. Further, in situ environmental scanning electron microscopy examination of the deformation and failure of the lattices revealed that the standard specimens exhibit a more ductile behavior, compared to the novel ones.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The sensitivity of tokamak magnetohydrodynamics stability on the edge equilibrium

Due to the X-point singularity, the safety factor tends to infinity as approaching to the last closed flux surface. The numerical treatments of the near X-point behavior become challenging both for equilibrium and stability. The usual solution is to cut off a small fraction of edge region for system stability evaluation or simply use an up-down symmetric equilibrium without X-point as an approximation. In this work, we assess the sensitivity of this type of equilibrium treatments on the stability calculation. It is found that the system stability can depend strongly on the safety factor value (qa) at the edge after the cutting-off. When the edge safety factor value falls in the vicinity of a rational mode number (referred to as the resonant gap), the system becomes quite unstable due to the excitation of the peeling type modes. Instead, when the edge safety factor is outside the resonant gaps, the system is much more stable and the predominant modes become the usual external kink (or ballooning and infernal) type. It is also found that the resonant gaps become smaller and smaller as qa increases. The ideal magnetohydrodynamic peeling ballooning stability diagram is widely used to explain the experimental observations, and the current results indicate that the conventional peeling ballooning stability diagram based on the simplified equilibrium needs to be reexamined.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Renormalization constants for 2-twist operators in twisted mass QCD

Perturbative and nonperturbative results on the renormalization constants of the fermion field and the twist-2 fermion bilinears are presented with emphasis on the nonperturbative evaluation of the one-derivative twist-2 vector and axial-vector operators. Nonperturbative results are obtained using the twisted mass Wilson fermion formulation employing two degenerate dynamical quarks and the tree-level Symanzik improved gluon action. The simulations have been performed for pion masses in the range of about 450-260 MeV and at three values of the lattice spacing a corresponding to {beta}=3.9, 4.05, 4.20. Subtraction of O(a{sup 2}) terms is carried out by performing the perturbative evaluation of these operators at 1-loop and up to O(a{sup 2}). The renormalization conditions are defined in the RI{sup '}-MOM scheme, for both perturbative and nonperturbative results. The renormalization factors, obtained for different values of the renormalization scale, are evolved perturbatively to a reference scale set by the inverse of the lattice spacing. In addition, they are translated to MS at 2 GeV using 3-loop perturbative results for the conversion factors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High-Precision Determination of Oxygen $K_{α}$ Transition Energy Excludes Incongruent Motion of Interstellar Oxygen

We demonstrate a widely applicable technique to absolutely calibrate the energy scale of x-ray spectra with experimentally well-known and accurately calculable transitions of highly charged ions, allowing us to measure the K-shell Rydberg spectrum of molecular O 2 with 8 meV uncertainty. Here, we reveal a systematic ~450 meV shift from previous literature values, and settle an extraordinary discrepancy between astrophysical and laboratory measurements of neutral atomic oxygen, the latter being calibrated against the aforementioned O 2 literature values. Because of the widespread use of such, now deprecated, references, our method impacts on many branches of x-ray absorption spectroscopy. Moreover, it potentially reduces absolute uncertainties there to below the meV level.

74 ATOMIC AND MOLECULAR PHYSICS↗

Uncovering hidden bias in neutron diffraction residual strain measurements

When calculating residual strain via neutron or X-ray diffraction, uncertainties propagated from the peak fit are often inadequate to describe the true scatter of measurements about a singular strain state, such as one that should describe a macroscopic continuum. Because diffraction is inherently a selective process, orientation-dependent scatter arises from the sub-sampling of strong microstructure and strain gradients. This paper investigates the appropriateness of propagated uncertainties with reference to their original intention, i.e. noise about a mean value. Thirty-six unique orientations of strain measurements are taken at multiple locations within an additive friction-stir deposition component with fine-scale gradients (∼200 µm) of plastic strain, texture and residual elastic strain. Multiple strain and stress calculation pathways are compared: direct substitution of three measurements into Hooke's law, direct inversion of any six unique orientations into the strain state tensor and thirty-six measurement least-squares estimation. For the last two cases, the appropriateness of the uncertainty interval is statistically evaluated on the basis of a physical constraint: common agreement under the strain transformation law. For this sample, the direct inversion of six measurements retains a conservative estimate of the uncertainty. However, propagated uncertainties in the least-squares solution greatly underestimate the true experimental scatter. A simple pathway to estimate appropriate uncertainty intervals is suggested. These results demonstrate that the interpretation of uncertainty in residual strain is strongly dependent on intrinsic sample-dependent effects, and that oversampling orientations and statistical analysis can give more accurate results with realistic uncertainties.

36 MATERIALS SCIENCE↗

Quantifying the effect of anode surface roughness on diagnostic x-ray spectra using Monte Carlo simulation

Purpose: The accurate prediction of x-ray spectra under typical conditions encountered in clinical x-ray examination procedures and the assessment of factors influencing them has been a long-standing goal of the diagnostic radiology and medical physics communities. In this work, the influence of anode surface roughness on diagnostic x-ray spectra is evaluated using MCNP4C-based Monte Carlo simulations. Methods: An image-based modeling method was used to create realistic models from surface-cracked anodes. An in-house computer program was written to model the geometric pattern of cracks and irregularities from digital images of focal track surface in order to define the modeled anodes into MCNP input file. To consider average roughness and mean crack depth into the models, the surface of anodes was characterized by scanning electron microscopy and surface profilometry. It was found that the average roughness (R{sub a}) in the most aged tube studied is about 50 {mu}m. The correctness of MCNP4C in simulating diagnostic x-ray spectra was thoroughly verified by calling its Gaussian energy broadening card and comparing the simulated spectra with experimentally measured ones. The assessment of anode roughness involved the comparison of simulated spectra in deteriorated anodes with those simulated in perfectly plain anodes considered as reference. From these comparisons, the variations in output intensity, half value layer (HVL), heel effect, and patient dose were studied. Results: An intensity loss of 4.5% and 16.8% was predicted for anodes aged by 5 and 50 {mu}m deep cracks (50 kVp, 6 deg. target angle, and 2.5 mm Al total filtration). The variations in HVL were not significant as the spectra were not hardened by more than 2.5%; however, the trend for this variation was to increase with roughness. By deploying several point detector tallies along the anode-cathode direction and averaging exposure over them, it was found that for a 6 deg. anode, roughened by 50 {mu}m deep cracks, the reduction in exposure is 14.9% and 13.1% for 70 and 120 kVp tube voltages, respectively. For the evaluation of patient dose, entrance skin radiation dose was calculated for typical chest x-ray examinations. It was shown that as anode roughness increases, patient entrance skin dose decreases averagely by a factor of 15%. Conclusions: It was concluded that the anode surface roughness can have a non-negligible effect on output spectra in aged x-ray imaging tubes and its impact should be carefully considered in diagnostic x-ray imaging modalities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Predicting oropharyngeal tumor volume throughout the course of radiation therapy from pretreatment computed tomography data using general linear models

Purpose: The purpose of this work was to develop and evaluate the accuracy of several predictive models of variation in tumor volume throughout the course of radiation therapy. Methods: Nineteen patients with oropharyngeal cancers were imaged daily with CT-on-rails for image-guided alignment per an institutional protocol. The daily volumes of 35 tumors in these 19 patients were determined and used to generate (1) a linear model in which tumor volume changed at a constant rate, (2) a general linear model that utilized the power fit relationship between the daily and initial tumor volumes, and (3) a functional general linear model that identified and exploited the primary modes of variation between time series describing the changing tumor volumes. Primary and nodal tumor volumes were examined separately. The accuracy of these models in predicting daily tumor volumes were compared with those of static and linear reference models using leave-one-out cross-validation. Results: In predicting the daily volume of primary tumors, the general linear model and the functional general linear model were more accurate than the static reference model by 9.9% (range: −11.6%–23.8%) and 14.6% (range: −7.3%–27.5%), respectively, and were more accurate than the linear reference model by 14.2% (range: −6.8%–40.3%) and 13.1% (range: −1.5%–52.5%), respectively. In predicting the daily volume of nodal tumors, only the 14.4% (range: −11.1%–20.5%) improvement in accuracy of the functional general linear model compared to the static reference model was statistically significant. Conclusions: A general linear model and a functional general linear model trained on data from a small population of patients can predict the primary tumor volume throughout the course of radiation therapy with greater accuracy than standard reference models. These more accurate models may increase the prognostic value of information about the tumor garnered from pretreatment computed tomography images and facilitate improved treatment management.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Image simulation and a model of noise power spectra across a range of mammographic beam qualities

Purpose: The aim of this work is to create a model to predict the noise power spectra (NPS) for a range of mammographic radiographic factors. The noise model was necessary to degrade images acquired on one system to match the image quality of different systems for a range of beam qualities. Methods: Five detectors and x-ray systems [Hologic Selenia (ASEh), Carestream computed radiography CR900 (CRc), GE Essential (CSI), Carestream NIP (NIPc), and Siemens Inspiration (ASEs)] were characterized for this study. The signal transfer property was measured as the pixel value against absorbed energy per unit area (E) at a reference beam quality of 28 kV, Mo/Mo or 29 kV, W/Rh with 45 mm polymethyl methacrylate (PMMA) at the tube head. The contributions of the three noise sources (electronic, quantum, and structure) to the NPS were calculated by fitting a quadratic at each spatial frequency of the NPS against E. A quantum noise correction factor which was dependent on beam quality was quantified using a set of images acquired over a range of radiographic factors with different thicknesses of PMMA. The noise model was tested for images acquired at 26 kV, Mo/Mo with 20 mm PMMA and 34 kV, Mo/Rh with 70 mm PMMA for three detectors (ASEh, CRc, and CSI) over a range of exposures. The NPS were modeled with and without the noise correction factor and compared with the measured NPS. A previous method for adapting an image to appear as if acquired on a different system was modified to allow the reference beam quality to be different from the beam quality of the image. The method was validated by adapting the ASEh flat field images with two thicknesses of PMMA (20 and 70 mm) to appear with the imaging characteristics of the CSI and CRc systems. Results: The quantum noise correction factor rises with higher beam qualities, except for CR systems at high spatial frequencies, where a flat response was found against mean photon energy. This is due to the dominance of secondary quantum noise in CR. The use of the quantum noise correction factor reduced the difference from the model to the real NPS to generally within 4%. The use of the quantum noise correction improved the conversion of ASEh image to CRc image but had no difference for the conversion to CSI images. Conclusions: A practical method for estimating the NPS at any dose and over a range of beam qualities for mammography has been demonstrated. The noise model was incorporated into a methodology for converting an image to appear as if acquired on a different detector. The method can now be extended to work for a wide range of beam qualities and can be applied to the conversion of mammograms.

60 APPLIED LIFE SCIENCES↗

Livermore Metagenomics Analysis Toolkit

LMAT is designed to take as input a collection of raw metagenomic sequencer reads, and search each read against a reference genome database and assign a taxonomic label and confidence value to each read and report a summary of the predicted taxonomic contents of the metagenomic sample.

Source record↗

The Precision of Product Consistency Tests with Reference Glasses ARM-1 and SRM 623

An interlaboratory study (ILS) was conducted in 2014 to measure the precision with which the ASTM-International product consistency test method A (PCT-A) can be performed using properly prepared samples of reference glass ARM-1 or SRM 623 and test parameter values near the centers of ranges specified in procedure ASTM C1285. The ILS did not evaluate the full range of test parameter values allowed in the PCT-A method and the results do not represent the precision that should be expected if extreme values of the ranges are used. However, the precision measured in the ILS quantified the precision of tests conducted with mean parameters that were used to estimate the effects of individual parameters. Follow-on tests were conducted to assess the effects of several individual test parameter values on the test response and uncertainties in the derived glass dissolution rates. The effects of particle size distributions in glass samples prepared by wet- and dry-sieving methods, methods to remove fines, and the limiting parameter values for the water-to-glass (w/g) mass ratio and test duration allowed in PCT-A were measured. Test responses for all variations except test duration exceeded the precision measured in the ILS for conducting triplicate PCT-A tests within a single laboratory. The accuracy of glass dissolution rates derived from PCT results benefits from using a tighter control of these test variables than required in ASTM C1285. Comparison with previous analyses of the method shows how use of the relative standard deviation to represent the test precision can be misleading, and that the mean response and standard deviation should both be considered.

36 MATERIALS SCIENCE↗

Livermore Metagenomics Analysis Toolkit

LMAT is designed to take as input a collection of raw metagenomic sequencer reads, and search each read against a reference genome database and assign a taxonomic label and confidence value to each read and report a summary of the predicted taxonomic contents of the metagenomic sample.

Source record↗

Development of Alternate Soil Clean-Up Goals for Hanford Waste Sites Using Fate and Transport Modeling

Remedial Action Goals (RAGs) for soil contaminant levels that are protective of groundwater have been determined for the Removal/Treatment/Disposal (RTD) sites at the 200-UW-1 Operable Unit on the Hanford Site. The RAG values were determined using a methodology involving the back-calculation of soil contaminant levels protective of groundwater (i.e., resulting groundwater concentrations are {<=} MCLs) in conjunction with the fate and transport modeling as a risk-based alternative to the currently prescribed use of background or detection limit default values. This methodology is important for waste management activities at the Hanford Site because it provides risk-based metrics and a technical basis for determining the levels of contamination 'left in place' in the Hanford Site vadose zone that are protective of human health and the environment. The methodology and the use of fate and transport modeling described here comply with federal guidelines for the use of environmental models. This approach is also consistent with one of several allowable methods identified in State guidelines for deriving soil concentrations for ground water protection. Federal and state guidelines recommend the use of site-specific information and data in risk-based assessments of risk and/or protectiveness. The site-specific characteristics of the Hanford Site, which include consideration of the semi-arid climate, an unsaturated zone thickness of over 80 m (262 feet), and associated/other site features and processes, are integral for the risk-based assessments associated with the protection of groundwater pathway. This methodology yields soil cleanup values (RAGs) for the 200-UW-1 OU waste sites selected for the removal/treatment/disposal (RTD) remedy. These proposed RAGs for uranium, nitrate, and technetium-99 are derived from soil concentrations calculated not to cause contamination of groundwater at levels that exceed the ground water MCLs, and are 40 to 200 times greater than currently prescribed default values. The proposed RAG soil concentration values derive from the results of the fate and transport modeling for a reference volume of contaminated soil extending to a depth of 15 feet, and also for a depth extending from 15 feet to 30 feet. The site-specific parameters for the 200-UW-1 OU RTD waste sites used to calculate the proposed RAG values, and the fate and transport modeling are also described. The assessment of uncertainties, assumptions, and model limitations indicate that the model is capable of adequately representing the Hanford vadose zone system and that the estimated soil cleanup levels are conservatively biased toward over-estimation of groundwater impacts. The risk-based metrics provided by this methodology can potentially greatly reduce the amount of excavation needed at the hundreds of RTD waste sites, and also have significant implications for deeper vadose zone applications. These implications include an improved technical basis for remedy selection, decisions, characterization, and stakeholder communication and cost savings in the range of hundreds of millions of dollars. (authors)

54 ENVIRONMENTAL SCIENCES↗

Influence of source batch S{sub K} dispersion on dosimetry for prostate cancer treatment with permanent implants

Purpose: In clinical practice, specific air kerma strength (S{sub K}) value is used in treatment planning system (TPS) permanent brachytherapy implant calculations with {sup 125}I and {sup 103}Pd sources; in fact, commercial TPS provide only one S{sub K} input value for all implanted sources and the certified shipment average is typically used. However, the value for S{sub K} is dispersed: this dispersion is not only due to the manufacturing process and variation between different source batches but also due to the classification of sources into different classes according to their S{sub K} values. The purpose of this work is to examine the impact of S{sub K} dispersion on typical implant parameters that are used to evaluate the dose volume histogram (DVH) for both planning target volume (PTV) and organs at risk (OARs). Methods: The authors have developed a new algorithm to compute dose distributions with different S{sub K} values for each source. Three different prostate volumes (20, 30, and 40 cm{sup 3}) were considered and two typical commercial sources of different radionuclides were used. Using a conventional TPS, clinically accepted calculations were made for {sup 125}I sources; for the palladium, typical implants were simulated. To assess the many different possible S{sub K} values for each source belonging to a class, the authors assigned an S{sub K} value to each source in a randomized process 1000 times for each source and volume. All the dose distributions generated for each set of simulations were assessed through the DVH distributions comparing with dose distributions obtained using a uniform S{sub K} value for all the implanted sources. The authors analyzed several dose coverage (V{sub 100} and D{sub 90}) and overdosage parameters for prostate and PTV and also the limiting and overdosage parameters for OARs, urethra and rectum. Results: The parameters analyzed followed a Gaussian distribution for the entire set of computed dosimetries. PTV and prostate V{sub 100} and D{sub 90} variations ranged between 0.2% and 1.78% for both sources. Variations for the overdosage parameters V{sub 150} and V{sub 200} compared to dose coverage parameters were observed and, in general, variations were larger for parameters related to {sup 125}I sources than {sup 103}Pd sources. For OAR dosimetry, variations with respect to the reference D{sub 0.1cm{sup 3}} were observed for rectum values, ranging from 2% to 3%, compared with urethra values, which ranged from 1% to 2%. Conclusions: Dose coverage for prostate and PTV was practically unaffected by S{sub K} dispersion, as was the maximum dose deposited in the urethra due to the implant technique geometry. However, the authors observed larger variations for the PTV V{sub 150}, rectum V{sub 100}, and rectum D{sub 0.1cm{sup 3}} values. The variations in rectum parameters were caused by the specific location of sources with S{sub K} value that differed from the average in the vicinity. Finally, on comparing the two sources, variations were larger for {sup 125}I than for {sup 103}Pd. This is because for {sup 103}Pd, a greater number of sources were used to obtain a valid dose distribution than for {sup 125}I, resulting in a lower variation for each S{sub K} value for each source (because the variations become averaged out statistically speaking)

60 APPLIED LIFE SCIENCES↗