Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reference Values”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Completed Beltrami-Michell Formulation for Analyzing Radially Symmetrical Bodies

A force method formulation, the completed Beltrami-Michell formulation (CBMF), has been developed for analyzing boundary value problems in elastic continua. The CBMF is obtained by augmenting the classical Beltrami-Michell formulation with novel boundary compatibility conditions. It can analyze general elastic continua with stress, displacement, or mixed boundary conditions. The CBMF alleviates the limitations of the classical formulation, which can solve stress boundary value problems only. In this report, the CBMF is specialized for plates and shells. All equations of the CBMF, including the boundary compatibility conditions, are derived from the variational formulation of the integrated force method (IFM). These equations are defined only in terms of stresses. Their solution for kinematically stable elastic continua provides stress fields without any reference to displacements. In addition, a stress function formulation for plates and shells is developed by augmenting the classical Airy's formulation with boundary compatibility conditions expressed in terms of the stress function. The versatility of the CBMF and the augmented stress function formulation is demonstrated through analytical solutions of several mixed boundary value problems. The example problems include a composite circular plate and a composite circular cylindrical shell under the simultaneous actions of mechanical and thermal loads.

Kaljevic, Igor↗

Use of Spectral Analysis of Singular Values as a Test Metric for Impedance Matched Multi-Axis Test Trials

One of many challenges in the implementation of multiple exciter testing is establishing a reasonable set of test metrics to measure the quality of testing. This is especially true in the application of Impedance Matched Multi-Axis Testing; in that it is possible to have very large spectral density matrices that serve as reference criteria. While there exist plotting schemes to view a spectral density matrix, it is often necessary to break the overlay of reference and test results into subsections of the matrices to get sufficient resolution to interpret the data. In addition, as one attempts to control multiple locations on a structure, implementation of classical single degree-of freedom test tolerances across all channels and associated cross spectra is simply not feasible. Hence it is challenging to evaluate overall test quality. The use of spectral views of the dominant singular values from the singular value decomposition of the spectral density matrices and metrics based upon them is proposed for establishing a set of compact metrics for evaluating test quality. A laboratory experiment will be included to demonstrate this proposed technique.

Vibration Testing↗

Synthetic aperture radar imaging of ocean waves - Comparison with wave measurements

Synthetic aperture radar images of ocean waves were obtained in conjunction with reference wave data near Marineland, Florida, December 14, 1975. Each of the various types of measurements were processed into a form that allowed direct comparisons with the others. Maxima of radar spectra occurred at the same frequencies as the maxima of reference wave height spectra. In a comparison of a radar spectrum with observed spectra of wave height, wave orbital velocity, and surface slope the high-frequency portion of the radar spectrum lay near and between the wave height and the orbital velocity spectra but differed significantly from the surface slope spectrum. The radar-derived mean directions and model-fitted directional spreads of wave energy were close to the values from a directional wave buoy and indicated the accuracy of radar measurements of wave direction. However, a directional plot of a radar spectrum near shore at the frequency of the maximum showed a sharper peak than such a plot of a fitted spectrum derived from reference data.

Mcleish, W.↗

Space shuttle: A comparison of wind tunnel facility data on the 040A space shuttle orbiter configuration

A series of comparisons made on the longitudinal and lateral directional stability and control characteristics of the baseline 040A space shuttle orbiter configuration is documented. The data used for the comparisons were obtained from five wind tunnel tests conducted in four different wind tunnel facilities. The media for comparison were the aerodynamic slope values plotted as a function of Mach number for the different facilities. The slopes were computed using the SADSAC system and have been reduced relative to a common reference system. Data used for the comparison were selected based on a common baseline configuration. Identical configurations were available in all cases except MSFC 551 where an off-baseline vertical tail was tested. Some of the factors considered in comparing the various data were balance operating ranges and sensitivities, Reynolds number differences, scaling effects and control deflection accuracies.

Gyorfi, R. A.↗

Parametric test results of a swirl-can combustor

Pollutant levels of oxides of nitrogen, unburned hydrocarbons, and carbon monoxide were measured for three models of an experimental, annular swirl can combustor. The combustor was 1.067 meters in outer diameter, incorporated 120 modules, and was specifically designed for elevated exit temperature performance. Test conditions included combustor inlet temperatures of 589, 756 and 839 K, inlet pressures of 3 to 6.4 atmospheres, reference velocities of 21 to 38 meters per second and combustor equivalence ratios, based on total combustor flows of 0.206 to 1.028. Maximum oxides of nitrogen emission index values occurred at an equivalence ratio of 0.7 with lower values measured for both higher and lower equivalence ratios. Oxides of nitrogen concentrations, to the 0.7 level with 756 K inlet air, were correlated for the three models by a combined parameter consisting of measured flow and geometric parameters. Effects of the individual parameters comprising the correlation are also presented.

Niedzwiecki, R. W.↗

Electrodes for the thermionic converters, phase 2 - 3

The characteristics of electrodes for thermionic converters are discussed. A metal/ceramic Marchuk tube was constructed and operated with a quiescent cesium vapor plasma corresponding to cesium liquid reservoir temperatures from 376 to 427 K. The work function characteristics of tantalum test emitters coated with anodic films were measured to evaluate the applicability of the materials as the collector surface in a plasma mode thermionic converter. Work function minimum values between 1.4 and 1.5 electron volts were observed. The effect of the electronegative surface layers was partially obscured by additive vapor impurities detected by the clean tantalum reference emitter.

Desteese, J. G.↗

Parametric test results of a swirl-can combustor.

Pollutant levels of oxides of nitrogen, unburned hydrocarbons, and carbon monoxide were measured for three models of an experimental, annular swirl can combustor. The combustor was 1.067 meters in outer diameter, incorporated 120 modules, and was specifically designed for elevated exit temperature performance. Test conditions included combustor inlet temperatures of 589, 756, and 839 K, inlet pressures of 3 to 6.4 atmospheres, reference velocities of 21 to 38 meters per second, and combustor equivalence ratios, based on total combustor flows, of 0.206 to 1.028. Maximum oxides of nitrogen emission index values occurred at an equivalence ratio of 0.7 with lower values measured for both higher and lower equivalence ratios.

Niedzwiecki, R. W.↗

Direct reading inductance meter

A direct reading inductance meter comprised of a crystal oscillator and an LC tuned oscillator is presented. The oscillators function respectively to generate a reference frequency, f(r), and to generate an initial frequency, f(0), which when mixed produce a difference equal to zero. Upon connecting an inductor of small unknown value in the LC circuit to change its resonant frequency to f(x), a difference frequency (f(r)-f(x)) is produced that is very nearly a linear function of the inductance of the inductor. The difference frequency is measured and displayed on a linear scale in units of inductance.

Kolby, R. B.↗

Effects of differential rotation on the gravitational figures of Jupiter and Saturn

It is assumed that observed zonal currents in the atmospheres of Jupiter and Saturn correspond to a state of permanent rotation, and that the angular velocity is constant on cylindrical surfaces parallel to the rotation axis. The equation of hydrostatic equilibrium for a rotating planet is solved under these restrictive assumptions, and the effect of the hypothesized rotation state on the planet's gravity harmonics and external shape is investigated. Spacecraft data on zonal currents are used to derive nearly model-independent corrections to the first four zonal gravity harmonic coefficients, which can be used to correct observed gravity harmonics to values appropriate for solid-body rotation. If the assumed rotation state is applicable, then zonal currents lead to measurable topography of isopycnic surfaces with respect to the reference figure defined by the magnetospheric rotation period and the gravity harmonics. The amplitude of the topography is on the order of 5 km for Jupiter and 60 km for Saturn.

Hubbard, W. B.↗

Earth's partial pressure of CO2 over the past 100-500 Ma; evidence from Ce anomalies in mostly shallow seas (less than 200 m) as recorded in carbonate sediments, 2

We reported the direct relationship of Ce anomalies recorded in 0.2-119 Ma CaCO3 sediments (Ce(sup A*)) to the Ce anomalies in the parental Pacific deep seawater (Ce(sup A)) and their relationship to atmospheric P(CO2) relative to present P(CO2). We have analyzed continental CaCO3 samples that were deposited in ancient oceans and shallow sea platforms less than 200 m over central USA, central Europe, China, and Saudi-Arabia/Oman. We have plotted Ce(sup A*) over the 75-470 Ma interval. For P(CO2) calculations, we assumed as a reference standard the less than 200 m mixed Pacific Ocean with a Ce(sup A) geometric mean of 0.22 and a range of 0.10-0.43. Because P(CO2) values obtained from reliable deep Pacific Ocean carbonates in the 67-119 Ma interval were similar to the present P(CO2) values, we have drawn a 1.0 ratio for that interval. Although there is considerable scatter among the approximately 150 Ma carbonates, the average Ce(sup A*) value suggests that P(CO2) increased during the early Cretaceous, from 1.0X at approximately 120 Ma to about 1.4X at approximately 150 Ma. At approximately 250 Ma, the average Ce(sup A*) in 13 shallow sea China carbonates agrees well with the single and more reliable approximately 250 Ma China carbonate deposited in deeper open platform. We suggest that P(CO2) ranged from 1.4-1.7X over the Jurassic and Triassic periods. At approximately 280 Ma, three China carbonates deposited in deeper open platforms and therefore considered more reliable are consistent with a European carbonate, which indicate Ce(sup A) and P(CO2) values similar to the present. The minimum at this time corresponds to the great Permo-Carboniferous glaciation. From 280 Ma to 470 Ma, the trend favors increasing Ce(sup A*) and corresponding P(CO2) values between 1.9-2.7X, with a more reliable value closer to 2.7X at 430 Ma because of the unknown higher temperature in the less than 100 m seawater over continental USA which was located just south of the equator at approximately 430 Ma.

Liu, Y.-G.↗

Spatial Standard Observer

The present invention relates to devices and methods for the measurement and/or for the specification of the perceptual intensity of a visual image. or the perceptual distance between a pair of images. Grayscale test and reference images are processed to produce test and reference luminance images. A luminance filter function is convolved with the reference luminance image to produce a local mean luminance reference image . Test and reference contrast images are produced from the local mean luminance reference image and the test and reference luminance images respectively, followed by application of a contrast sensitivity filter. The resulting images are combined according to mathematical prescriptions to produce a Just Noticeable Difference, JND value, indicative of a Spatial Standard Observer. SSO. Some embodiments include masking functions. window functions. special treatment for images lying on or near border and pre-processing of test images.

Watson, Andrw B.↗

Spatial Standard Observer

The present invention relates to devices and methods for the measurement and/or for the specification of the perceptual intensity of a visual image, or the perceptual distance between a pair of images. Grayscale test and reference images are processed to produce test and reference luminance images. A luminance filter function is convolved with the reference luminance image to produce a local mean luminance reference image. Test and reference contrast images are produced from the local mean luminance reference image and the test and reference luminance images respectively, followed by application of a contrast sensitivity filter. The resulting images are combined according to mathematical prescriptions to produce a Just Noticeable Difference, JND value, indicative of a Spatial Standard Observer, SSO. Some embodiments include masking functions, window functions, special treatment for images lying on or near borders and pre-processing of test images.

Watson, Andrew B.↗

Detection of Anomalies in the UV/Vis Reflectances from the Ozone Monitoring Instrument

Various instrumental or geophysical artifacts, such as saturation, stray light, or obstruction of light (either coming from the instrument or related to solar eclipses), negatively impact satellite measured ultraviolet and visible Earthshine radiance spectra and downstream retrievals of atmospheric and surface properties derived from these spectra. In addition, excessive noise such as from cosmic ray impacts, prevalent within the South Atlantic Anomaly, can also degrade satellite radiance measurements. Saturation specifically pertains to observations of very bright surfaces such as sun glint over open water or thick clouds. When saturation occurs, additional photoelectric charge generated at the saturated pixel may overflow to pixels adjacent to a saturated area and be reflected as a distorted image in the final sensor output.When these effects cannot be corrected to an acceptable level for science quality retrievals, flagging of the affected pixels is indicated. Here, we introduce a straightforward detection method that is based on the correlation, r, between the observed Earthshine radiance and solar irradiance spectraover a 10 nm-spectral range; our Decorrelation Index (DI for brevity) is simply defined as DI=1-r. DI increases with anomalous additive effects or excessive noise in either radiances, the most likely cause indata from theOzone Monitoring Instrument (OMI),or irradiances. DI is relatively straight-forward to use and interpret and can be 20computed for different wavelength intervals. We developed a set of DIs for two spectral channelsof the OMI, a hyperspectral pushbroom imaging spectrometer. For each OMI spatial measurement, we define 14 wavelength-dependent DIs within the OMI visible channel (350-498 nm) and 6 DIs in its ultraviolet 2 (UV2) channel (310-370 nm). As defined, DIs reflect a continuous range of deviations of observed spectra from the reference irradiance spectrum that are complementary to the binary Saturation Possibility Warning (SPW) flags currently provided for each individual spectral/spatial pixel in the OMI radiance data set. Smaller values of DI are also caused by a number of geophysical factors; this allows one to obtain interesting physical results on the global distribution of spectral variations.

Space sensor↗

Development of a Boundary Layer Property Interpolation Tool in Support of Orbiter Return To Flight

A new tool was developed to predict the boundary layer quantities required by several physics-based predictive/analytic methods that assess damaged Orbiter tile. This new tool, the Boundary Layer Property Prediction (BLPROP) tool, supplies boundary layer values used in correlations that determine boundary layer transition onset and surface heating-rate augmentation/attenuation factors inside tile gouges (i.e. cavities). BLPROP interpolates through a database of computed solutions and provides boundary layer and wall data (delta, theta, Re(sub theta)/M(sub e), Re(sub theta)/M(sub e), Re(sub theta), P(sub w), and q(sub w)) based on user input surface location and free stream conditions. Surface locations are limited to the Orbiter s windward surface. Constructed using predictions from an inviscid w/boundary-layer method and benchmark viscous CFD, the computed database covers the hypersonic continuum flight regime based on two reference flight trajectories. First-order one-dimensional Lagrange interpolation accounts for Mach number and angle-of-attack variations, whereas non-dimensional normalization accounts for differences between the reference and input Reynolds number. Employing the same computational methods used to construct the database, solutions at other trajectory points taken from previous STS flights were computed: these results validate the BLPROP algorithm. Percentage differences between interpolated and computed values are presented and are used to establish the level of uncertainty of the new tool.

Greene, Francis A.↗

Investigation of the tone-burst tube for duct lining attenuation measurement

The tone burst technique makes practical the laboratory evaluation of potential inlet and discharge duct treatments. Tone burst apparatus requires only simple machined parts and standard components. Small, simply made, lining samples are quickly and easily installed in the system. Two small electromagnetric loudspeaker drivers produce peak sound pressure level of over 166 db in the 3-square-inch sample duct. Air pump available in most laboratories can produce air flows of over plus and minus Mach 0.3 in the sample duct. The technique uses short shaped pulses of sound propagated down a progressive wave tube containing the sample duct. The peak pressure level output of the treated duct is compared with the peak pressure level output of a substituted reference duct. The difference between the levels is the attenuation or insertion loss of the treated duct. Evaluations of resonant absorber linings by the tone burst technique check attenuation values predicted by empirical formulas based on full scale ducts.

Soffel, A. R.↗

The effect of water injection on nitric oxide emissions of a gas turbine combustor burning ASTM Jet-A fuel

Tests were conducted to determine the effect of water injection on oxides of nitrogen (NOx) emissions of a full annular, ram induction gas turbine combustor burning ASTM Jet-A fuel. The combustor was operated at conditions simulating sea-level takeoff and cruise conditions. Water at ambient temperature was injected into the combustor primary zone at water-fuel ratios up to 2. At an inlet-air temperature of 589 K (600 F) water injection decreased the NOx emission index at a constant exponential rate: NOx = NOx (o) e to the -15 W/F power (where W/F is the water-fuel ratio and NOx(o) indicates the value with no injection). The effect of increasing combustor inlet-air temperature was to decrease the effect of the water injection. Other operating variables such as pressure and reference Mach number did not appear to significantly affect the percent reduction in NOx. Smoke emissions were found to decrease with increasing water injection.

Marchionna, N. R.↗

Determination of sea ice motion using digital SAR imagery

Precise, densely sampled maps of ice motion have been derived from digital Seasat SAR imagery, in order to determine the small scale spatial variability of ice formation. The SAR images were processed to remove geometric distortions, and then located to an accuracy of about 100 m by means of a spacecraft orbital data/SAR characteristics algorithm, independently of attitude and ground reference point data. Ice features common to an overlapping pair of images yielded vector plots of ice motion that indicate a high degree of spatial deformation, demonstrating the potential value of spaceborne SAR data.

Curlander, J. C.↗

Iterative-Transform Phase Retrieval Using Adaptive Diversity

A phase-diverse iterative-transform phase-retrieval algorithm enables high spatial-frequency, high-dynamic-range, image-based wavefront sensing. [The terms phase-diverse, phase retrieval, image-based, and wavefront sensing are defined in the first of the two immediately preceding articles, Broadband Phase Retrieval for Image-Based Wavefront Sensing (GSC-14899-1).] As described below, no prior phase-retrieval algorithm has offered both high dynamic range and the capability to recover high spatial-frequency components. Each of the previously developed image-based phase-retrieval techniques can be classified into one of two categories: iterative transform or parametric. Among the modifications of the original iterative-transform approach has been the introduction of a defocus diversity function (also defined in the cited companion article). Modifications of the original parametric approach have included minimizing alternative objective functions as well as implementing a variety of nonlinear optimization methods. The iterative-transform approach offers the advantage of ability to recover low, middle, and high spatial frequencies, but has disadvantage of having a limited dynamic range to one wavelength or less. In contrast, parametric phase retrieval offers the advantage of high dynamic range, but is poorly suited for recovering higher spatial frequency aberrations. The present phase-diverse iterative transform phase-retrieval algorithm offers both the high-spatial-frequency capability of the iterative-transform approach and the high dynamic range of parametric phase-recovery techniques. In implementation, this is a focus-diverse iterative-transform phaseretrieval algorithm that incorporates an adaptive diversity function, which makes it possible to avoid phase unwrapping while preserving high-spatial-frequency recovery. The algorithm includes an inner and an outer loop (see figure). An initial estimate of phase is used to start the algorithm on the inner loop, wherein multiple intensity images are processed, each using a different defocus value. The processing is done by an iterative-transform method, yielding individual phase estimates corresponding to each image of the defocus-diversity data set. These individual phase estimates are combined in a weighted average to form a new phase estimate, which serves as the initial phase estimate for either the next iteration of the iterative-transform method or, if the maximum number of iterations has been reached, for the next several steps, which constitute the outerloop portion of the algorithm. The details of the next several steps must be omitted here for the sake of brevity. The overall effect of these steps is to adaptively update the diversity defocus values according to recovery of global defocus in the phase estimate. Aberration recovery varies with differing amounts as the amount of diversity defocus is updated in each image; thus, feedback is incorporated into the recovery process. This process is iterated until the global defocus error is driven to zero during the recovery process. The amplitude of aberration may far exceed one wavelength after completion of the inner-loop portion of the algorithm, and the classical iterative transform method does not, by itself, enable recovery of multi-wavelength aberrations. Hence, in the absence of a means of off-loading the multi-wavelength portion of the aberration, the algorithm would produce a wrapped phase map. However, a special aberration-fitting procedure can be applied to the wrapped phase data to transfer at least some portion of the multi-wavelength aberration to the diversity function, wherein the data are treated as known phase values. In this way, a multiwavelength aberration can be recovered incrementally by successively applying the aberration-fitting procedure to intermediate wrapped phase maps. During recovery, as more of the aberration is transferred to the diversity function following successive iterations around the ter loop, the estimated phase ceases to wrap in places where the aberration values become incorporated as part of the diversity function. As a result, as the aberration content is transferred to the diversity function, the phase estimate resembles that of a reference flat.

Dean, Bruce H.↗