Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Meteorological applications of the Nimbus 4 temperature-humidity infrared radiometer, 6.7 micron channel data.

Midtropospheric circulation features under essentially clear sky conditions have been noted in the data of the 6.7-micron channel of the Nimbus 4 temperature-humidity infrared radiometer (THIR), while at the same time these features were undetected by the 11.5-micron channel of the same instrument. The characteristic response of the 6.7-micron channel to atmospheric water vapor emission is primarily from the 250-mb (10.5 km) to 500-mb (5.5 km) levels with a peak contribution at 350 mb (8 km). Dry and moist patterns seen in the 6.7-micron data on Feb. 21, 1971, have been integrated into a 400-mb moisture analysis over the United States. This analysis provided more detailed and timely information than was conventionally available about the advection of dry air aloft prior to development of the Mississippi Tornado of February 1971.

Allison, L. J.↗

Improved noise-adding radiometer for microwave receivers

Use of input switch and noise reference standard is avoided by using noise-adding technique. Excess noise from solid state noise-diode is coupled into receiver through directional coupler and square-wave modulated at low rate. High sensitivity receivers for radioastronomy applications are utilized with greater confidence in stability of radiometer.

Batelaan, P. D.↗

A combined radar-radiometer with variable polarization

An instrument is described that provides both radar and radiometer data at the same time. The antenna and receiver are time shared for the two sensor functions. The antenna polarization can be electronically scanned at rates up to 5000 changes for both the transmit and receive signal paths. This equipment is to investigate target signatures for remote sensing applications. The function of the equipment is described and the results for observations of asphalt, grass, and gravel surfaces are presented.

Martin, D. P.↗

PVF pyroelectric radiometer

Polyvinylfluoride (PVF) plastic film was found to be a good pyroelectric material. Radiometers using PVF were developed that exhibit high sensitivity and frequency response. Normalized detectivities of greater than 10 to the 8th power cm/Hz/w and responsivities on the order of 100,000 V/W were measured (500 C BB source, 0.1 Hz chopping frequency and 1 Hz bandwidth.)

Russell, L. D.↗

Field studies in support of Nimbus-E surface composition mapping radiometer

If the outputs of the two channels are spacially registered and combined to generate a third variable which reflects the differences between the two outputs, then this variable can then be redisplayed in image form and its magnitude should be relatable to the silica content of the rocks imaged. Two methods were proposed for generating this third variable, the first is to take the difference in apparent temperature between the two channels and the second is to ratio the voltage outputs of the two channels. The responses of the two channel high resolution surface composition mapping radiometer and the thermal channels of the MSDS scanner were calculated from data recorded with the NASA IR pallet and simulate the output of these systems had they been flying over the same targets as the IR pallet.

Lyon, R. J. P.↗

Visible infrared spin-scan radiometer

The visible infrared spin-scal radiometer (VISSR) may be considered as a camera system capable of simultaneously providing both visible and infrared earth and cloud cover pictures every 20 minutes from the geostationary synchronous meteorological satellite (SMS). With a 0.9-kilometer resolution in the visible spectrum and a 9-kilometer resolution in the IR spectrum, the VISSR/SMS SYSTEM makes its possible to study atmospheric dynamics through 24-hour continuous observation of cloud altitudes, patterns, motion, and temperature distributions.

Phenix, J. E.↗

Very high resolution radiometer

A very high resolution radiometer is reported that produces visible and infrared images onboard meteorological satellites. The device has a visible and an infrared channel, a resolution in both spectral bands of 0.9260 kilometers from a 1460 kilometer polar orbit, and scans from horizon to horizon. A two stage radiant cooler with cooled outer housing permits operation in the 100 degrees kelvin range.

Schulman, J. R.↗

Meteorological interpretations of the images from Nimbus 5 electrically scanned microwave radiometer

The Electrically Scanned Microwave Radiometer on the Nimbus 5 satellite measures microwave radiation in a band centered at 1.55 cm. It scans perpendicular to the satellite motion from 50 deg to the left to 50 deg to the right in the 78 steps every 4 seconds producing an image with a best resolution of 25 km. It is shown that these images can be used to delineate areas of rain over the oceans. This data can be used to approximate the location of fronts, the rain/snow boundary and secondary cyclogenesis.

Wilheit, T.↗

Active cavity radiometer.

The active cavity radiometer (ACR) is a pyrheliometer that accurately defines the absolute radiation scale. The physics of the pyrheliometric method and the ACR approach to this method are presented in detail. A mathematical abstraction of the method is generated through a quasi-equilibrium analysis of the power balance of the ACR's cavity detector. An error analysis is carried out on the quasi-equilibrium equation to determine the uncertainties of ACR measurements relative to the absolute radiation scale. The uncertainty of ACR measurements as a function of irradiance level is presented in graphical form.

Willson, R. C.↗

A multispectral study of an extratropical cyclone with Nimbus 3 medium resolution infrared radiometer data

Four registered channels (0.2 to 4, 6.5 to 7, 10 to 11, and 20 to 23 microns) of the Nimbus 3 Medium Resolution Infrared Radiometer (MRIR) were used to study 24-hr changes in the structure of an extratropical cyclone during a 6-day period in May 1969. Use of a stereographic-horizon map projection insured that the storm was mapped with a single perspective throughout the series and allowed the convenient preparation of 24-hr difference maps of the infrared radiation fields. Single-channel and multispectral analysis techniques were employed to establish the positions and vertical slopes of jetstreams, large cloud systems, and major features of middle and upper tropospheric circulation. Use of these techniques plus the difference maps and continuity of observation allowed the early detection of secondary cyclones developing within the circulation of the primary cyclone. An automated, multispectral cloud-type identification technique was developed, and comparisons that were made with conventional ship reports and with high-resolution visual data from the image dissector camera system showed good agreement.

Holub, R.↗

Monitoring atmospheric pollutants with a heterodyne radiometer transmitter-receiver

The presence of selected atmospheric pollutants can be determined by transmitting an infrared beam of proper wavelength through the atmosphere, and detecting the reflections of the transmitted beam with a heterodyne radiometer transmitter-receiver using part of the laser beam as a local oscillator. The particular pollutant and its absorption line strength to be measured are selected by the laser beam wave length. When the round-trip path for the light is known or measured, concentration can be determined. Since pressure (altitude) will affect the shape of the molecular absorption line of a pollutant, tuning the laser through a range of frequencies, which includes a part of the absorption line of the pollutant of interest, yields pollutant altitude data from which the altitude and altitude profile is determined.

Menzies, R. T.↗

Infrared scanning radiometer

The Apollo 17 infrared scanning radiometer (ISR) experiment for mapping lunar surface thermal emission is reported. The instrument, lunar surface coverage, and the data obtained are discussed.

Low, F. J.↗

Steady state thermal radiometers

A radiometer is described operating in a vacuum under steady state conditions. The front element is an aluminum sheet painted on the outer side with black or other absorptive material of selected characteristics. A thermocouple is bonded to the inner side of the aluminum sheet. That is backed by highly insulative layers of glass fiber and crinkled, aluminized Mylar polyester. Those layers are backed with a sturdy, polyester sheet, and the entire lamination is laced together by nylon cords. The device is highly reliable in that it does not drift out of calibration, and is significantly inexpensive.

Loose, J. D.↗

Surface composition mapping radiometer instrument

The design, development, and fabrication of a three-channel scanning radiometer are discussed. The instrument was flown on Nimbus 5 satellite and measured infrared energy in the 8.3 to 9.3, 10.2 to 11.2, and 0.8 to 1.1 micron spectral regions. The instrument parameters are presented. Theoretical discussions of the instrument subassemblies are provided. Operational details of the mechanical and electrical portions of the instrument are included.

Source record↗

A filter-wheel solar radiometer for atmospheric transmission studies

A filter-wheel solar radiometer has been developed for monitoring the atmospheric optical depth at multiple narrow-wavelength intervals in the visible and near IR regions of the spectrum. Measurements of the direct solar radiations are converted to a digital format and stored in punched tape for eventual analysis by a computer. During stable clear weather condition, the instrument is capable of providing monochromatic optical depths to an estimated rms accuracy of 0.005.

Shaw, G. E.↗

Design and performance characteristics of the vertical temperature profile radiometer /VTPR/ for atmospheric temperature soundings

Various design characteristics and performance achievements of the vertical temperature profile radiometer (VTPR) are discussed. It is shown that the VTPR provides a relative calibration accuracy of better than 0.1% rms of the full dynamic range and has been operating successfully in space on the ITOS spacecraft for more than eleven months. The absolute accuracy achievable between in-flight calibrations of 6 minutes, or between 2-hour calibrations using optical temperature correction factors, is better than an rms value of 0.15% of full scale. The radiometric correlation between the VTPR in-flight calibration source and a reference standard blackbody is better than an rms value of 0.5% of full scale.

Falbel, G.↗

Air pollution - Remote detection of several pollutant gases with a laser heterodyne radiometer

An infrared heterodyne radiometer with a spectral resolution of 0.04 reciprocal centimeters has been used to remotely detect samples of ozone, sulfur dioxide, ammonia, and ethylene at room temperature, and samples of nitric oxide at 390 K. Each gas was observed in a background of nitrogen or oxygen at atmospheric pressure. Sensitivities to some of these gases are adequate for detection of ambient concentrations as low as a few parts per billion.

Menzies, R. T.↗

Microwave radiometer measurements of the Cape Cod Canal

Microwave radiometer measurements were conducted from a railroad bridge which spans the Cape Cod Canal in Massachusetts. Data were collected as a function of viewing angle and polarization at frequencies of 1.4, 4.0, and 7.5 GHz. The results compare differences in the microwave emmissivity of a smooth vs rough water surface. Results are also given which show the effects of roughness on the bistatic scattering of sunlight.

Swift, C. T.↗